Nokia BTS2500C User Manual

Exhibit 8 Installation and Operation Manual FCC ID: PHX-BTS2500C
Exhibit 8
Installation and
Operation Manual
NextNet Wireless, Inc. 9555 James Ave. South Suite 270 Bloomington, MN 55431 Page 1 of 117 6/16/2005
®
Configuring, Installing, and Using Carrier Infrastructure
Broadband Wireless Access System
Part Number: 104-0350-0004_DRAFT
i
BaseConnect, Expedience, NetProvision, and ProvisionLink are trademarks of NextNet Wireless, Inc. ©2000-2005 NextNet Wireless, Inc. All rights reserved. Revision 4_3_C
WARNING: This equipment has been tested with a 19 dBi gain antenna and found to comply with the FCC guidelines for Radio Frequency Radiation Exposure Limits as detailed below. For a single base 5 watt transmitter connected to the antenna, a minimum of 2 meters or 6.5 feet of separation between the antenna and all persons must be maintained. The minimum separation increases when additional base transmitting signals are combined and applied to the same antenna. Four base 5 watt transmitters combined to use a single antenna need a minimum separation of 4 meters or 13 feet from all persons.
Radio Frequency Radiation Exposure Limits.
TABLE 1. Limits for Maximum Permissible Exposure (MPE)
Frequency range (MHz)
0.3-3.0 614 1.63 *(100) 6
3.0-30 1842/f 4.89/f
30-300 61.4 0.163 1.0 6
300-1500 f/300 6
1500-100,000 5 6
0.3-1.34 614 1.63 *(100) 30
1.34-30 824/f 2.19/f
30-300 27.5 0.073 .2 30
300-1500 f/1500 30
1500-100,000 1.0 30
Electric field­strength (V/m)
(A) Limits for Occupational/Controlled Exposures
(B) Limits for General Population/Uncontrolled Exposure
Magnetic field­strength (A/m)
Power density (mW/cm 2)
2
*(900/f
)
2
)
*(180/f
Averaging time (minutes)
6
30
f = frequency in MHz * = Plane-wave equivalent power density
NOTE 1 TO TABLE 1: Occupational/controlled limits apply in situations in which persons are exposed as a consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure.
Limits for occupational/controlled exposure also apply in situations when an individual is transient through a location where occupational/controlled limits apply provided he or she is made aware of the potential for exposure.
NOTE 2 TO TABLE 1: General population/uncontrolled exposures apply in situations in which the general public may be exposed, or in which persons that are exposed as a consequence of their employment may not be fully aware of the potential for exposure or can not exercise control over their exposure.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy, and, if not installed and used in accordance with the installation manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own expense.
ii
TABLE 2. Technical Information
Transmitting power 1m watts to 2 watts
1m watts to 5 watts (high power option)
Operating voltage 120 VAC nominal
Frequency band 2500 - 2686 MHz TX/RX
Frequency stability ±1.0 ppm
Number of channels 31
Channel bandwidth 6 MHz
Modulation Orthogonal frequency division multiplex
Transmission Time division duplex/time division multiplex
This Class A digital apparatus complies with Canadian ICES-003.
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRENTY OF ANY KIND. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCT.
NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE ARE PROVIDED “AS IS” WITH ALL FAULTS. NEXTNET WIRELESS DISCLAIMS ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FOM A COUSRE OF DEALING, USAGE, OR TRADE PRACTICE.
IN NO EVENT SHALL NEXTNET WIRELESS OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OF DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF NEXTNET WIRELESS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
NextNet Wireless, Inc. recommends the antennas listed on the next page for base station installations:
iii
Windage
Depth
Width /
Length
Antenna
Cross Pol.
Front to
(in)
Diame-
ter (in)
(in)
Weight
(lbs)
Disc. (dB)
Back Ratio
(dB)
125 mph
125 mph
125 mph
125 mph
125 mph
Windage
Depth
(in)
Width /
Diameter
(in)
Length
(in)
Antenna
Weight (lbs)
Cross
Pol.
Disc.
Front to
Back Ratio
(dB)
125 mph
125 mph
125 mph
135 mph
(dB)
Manufacturer:Stella Doradus
Frequency Range:2500-2700 MHz
Special
Characteristics
Elevation
Beamwidth
Azimuth
Beam-
(dBi)
Polarization Gain
Model / Part
Number
(Degrees)
width
(Degrees)
26SD9005H Horizontal 19 90 5 -- 32 28 35.2 63.0 9.1 5.5 237 lbs @
Manufacturer:Stella Doradus
Frequency Range:3300-3600 MHz
Special
Characteristics
Elevation
Beamwidth
Azimuth
Beam-
(dBi)
Polarization Gain
Model / Part
Number
(Degrees)
width
(Degrees)
NextNet
Wire ess
Part Number
501-1009-2701 26SD9890NV Vertical 16 90 7 null fill 35 35 8.6 35.8 5.5 4.7 86 lbs @
501-1006-2701 26SD9860NV Vertical 17.5 60 7 null fill 40 30 8.75 35.8 5.5 4.7 86 lbs @
501-1002-2701 26SD98120NV Vertical 15 120 7 null fill 21 30 8.5 35.8 5.5 5.3 86 lbs @
501-3004-2601 26SD2360 Vertical 10 360 9 Omni N/A 26 2.86 43.3 1.9 -- 100 lbs @
NextNet
Wir ees s
Part Number
501-1009-3401 35SD9890NV Vertical 16 90 7 null fill 35 35 5.4 28 5.5 4.7 67 lbs @
501-1006-3401 35SD9860NV Vertical 17.5 60 7 null fill 33 30 6.5 28 5.5 4.7 67 lbs @
501-1002-3401 35SD98120NV Vertical 15 120 7 null fill 25 30 5.4 28 5.4 5.3 67 lbs @
501-3004-3601 35SD3360 Vertical 13 360 6 Omni N/A 28 5.72 42.1 1.9 -- 4.95 lbs @
iv
C
ONTENTS
About this guide
Preface overview .............................................................................. xiii
About this guide .............................................................................. xiii
Chapters in this guide ........................................................................................ xiv
Additional documentation .................................................................xv
Typographical conventions this guide uses .................................... xvi
Where to go for more help .............................................................. xvii
Technical support............................................................................................. xvii
Documentation additions and corrections................................................... xvii
Introduction to backhaul installations
Chapter overview .............................................................................. 1-1
System overview ................................................................................1-1
System overview ................................................................................................ 1-1
Infrastructure overview .................................................................................... 1-2
Installation overview .........................................................................1-5
Installation steps common to RMB and I-BTS ............................................ 1-5
Planning the installation ..................................................................1-7
Choosing an installation location .................................................................... 1-7
Assessing network access provider equipment needs ................................. 1-8
Planning for the antennas and antenna installation tips .............................. 1-9
Designing the deployment of base stations ................................................ 1-10
Configuring network architecture
Chapter overview ............................................................................ 2-11
Architecture overview ..................................................................... 2-11
Configuring switches ......................................................................2-12
Configuring the switch at the cell site .......................................................... 2-12
Configuring the head end switch .................................................................. 2-12
Configuring the ISP switch ............................................................................ 2-12
Selecting links and circuits ............................................................. 2-12
Selecting links based on maximum rate needed .........................................2-12
Selecting links based on another rate ........................................................... 2-13
v
Configuring the AP server
Chapter overview ............................................................................3-15
AP server overview .......................................................................... 3-15
Starting the AP server .....................................................................3-15
Configuring the AP server ..............................................................3-16
Defining AP server users and administrators .............................................3-16
Defining zone names ......................................................................................3-21
Defining ISPs ...................................................................................................3-22
Changing ISP information .............................................................................3-24
Monitoring ISPs and base stations ...............................................................3-25
Configuring a standby AP server
Chapter overview ............................................................................4-27
Standby AP server overview ............................................................4-27
Configuring the base station with standby AP server information 4-27
Setting up common configuration file and directory .................................4-28
Switching from the primary AP server to the secondary AP server ....... 4-30
Configuring base stations
Chapter overview ............................................................................5-31
Before you begin .............................................................................5-31
Setting up connection methods used to configure base stations ..5-32
Setting up terminal emulation access ...........................................................5-32
Setting up Telnet access ................................................................................. 5-32
Setting up web access ..................................................................................... 5-34
Setting up SNMP access ................................................................................ 5-35
Setting base station configuration parameters ...............................5-37
set airlink channel ........................................................................................... 5-37
set airlink downlink power .............................................................................5-38
set airlink downlink bias ................................................................................5-39
set system location .......................................................................................... 5-41
set system name ............................................................................................... 5-42
set airlink state .................................................................................................5-42
Recommended parameter changes ................................................5-42
set system cell ..................................................................................................5-42
set system sector ..............................................................................................5-42
set DHCP state ................................................................................................5-42
Setting legacy and management VLAN IDs ...............................................5-43
Setting up Syslog ............................................................................5-43
Configuring the authority that grants network access to CPEs ....5-44
Using base station caching feature for re-registering CPEs ..................... 5-44
Remote authority: setting up the provisioning server to grant CPEs
network access .................................................................................................5-45
vi Configuring, Installing, and Using Carrier Infrastructure
Local authority: setting up the base station to grant CPEs
network access .................................................................................................5-46
Configuring the time signal used by base stations ........................5-46
Configuring the GPS to supply the time signal .......................................... 5-46
Configuring a base station to supply a time signal .....................................5-47
Installing the integral base transceiver station (I-BTS)
Chapter overview ............................................................................6-49
Before you begin .............................................................................6-49
Cell wiring .......................................................................................6-50
Installation overview .......................................................................6-51
Antenna and bracket assembly for I-BTS ......................................6-51
Base station connectors ..................................................................6-55
Ethernet (data) and power connector ..........................................................6-56
TVS module connectors ................................................................................ 6-58
GPS connectors ...............................................................................................6-59
Serial interface connector ...............................................................................6-60
Antenna connector ......................................................................................... 6-60
Mounting and grounding the base station .....................................6-61
Mounting the base station to a wall ..............................................................6-61
Mounting the base station to a tower .......................................................... 6-62
Mounting the base station to a 19 inch rack ...............................................6-62
Grounding the base station ...........................................................................6-62
Connecting the antenna to the base station ...................................6-63
Antenna connection tips ................................................................................ 6-63
Connecting the antenna to the base station ................................................ 6-63
Connecting the GPS equipment to a base station .........................6-63
GPS equipment mounting tips .....................................................................6-63
Connecting the GPS unit to the base station ............................................. 6-64
Connecting to the backbone network ............................................6-64
Powering base stations ...................................................................6-65
Powering tips ...................................................................................................6-65
Powering the base station .............................................................................. 6-65
Installing the rackmount base station (RMB)
Chapter overview ............................................................................7-67
Before you begin .............................................................................7-67
Installation overview .......................................................................7-68
Installing the mounting bracket and attaching cabinet to
the 19-inch rack ...............................................................................7-69
Attaching the switch and power supply to the rack .......................7-70
vii
Installing the RMBs into the cabinet .............................................7-70
Connecting RMBs to cell (cell wiring) ........................................... 7-71
Connecting power to the RMBs .....................................................7-73
Powering the base station .............................................................................. 7-73
Powering tips ...................................................................................................7-75
Grounding the RMBs .....................................................................7-76
Turning on the RMB’s power ........................................................7-77
Base station connectors ..................................................................7-78
GPS connectors ...............................................................................................7-78
Power supply cable connections ................................................................... 7-79
Diagnostic cable connections ........................................................................7-79
Fuses and Ethernet cable connections on cabinet .....................................7-80
Wiring alarms for RMBs .................................................................7-82
Connecting to the backbone network ............................................7-82
Testing and managing the network
Chapter overview ............................................................................8-83
Testing the setup overview .............................................................8-83
Installing the ISP’s provisioning server .......................................................8-83
Testing the connection between the AP server and the
provisioning server ..........................................................................................8-84
Ensuring CPE access to ISP VLAN ............................................................ 8-84
Network management overview .....................................................8-84
Fault isolation overview .................................................................................8-85
Performance management overview ............................................................8-86
Configuration management overview ..........................................................8-86
Accounting feature overview ........................................................................8-86
GPS status codes
Appendix overview ........................................................................A-87
Supported frequency ranges
Appendix overview ........................................................................B-89
MMDS frequency range ................................................................................ B-89
3.3 GHz frequency range .............................................................................. B-91
3.5 GHz frequency range .............................................................................. B-91
viii Configuring, Installing, and Using Carrier Infrastructure
F
IGURES
About this guide
Introduction to backhaul installations
Rackmount base station (RMB) ...................................................................... 1-2
Rackmount base stations inside cabinet ........................................................ 1-3
Base station for indoor or outdoor installation ............................................ 1-4
Configuring network architecture
Configuring the AP server
AP server log in page ...................................................................................... 3-16
Access Provider Management page .............................................................. 3-17
Configure page ................................................................................................3-18
Administrators page ........................................................................................ 3-19
New User page ................................................................................................3-20
Base Station Attributes page ..........................................................................3-21
ISP Management page ....................................................................................3-22
Create new ISP page ....................................................................................... 3-23
ISP details page ................................................................................................3-24
Monitor ISPs- Base Stations page ................................................................ 3-25
Base Station Properties page .........................................................................3-26
Configuring a standby AP server
Configuration files to share between primary and secondary
AP servers ........................................................................................................4-28
Configuring base stations
Installing the integral base transceiver station (I-BTS)
Cell wiring diagram .........................................................................................6-50
Attaching L-shaped brackets to I-BTS ........................................................6-51
Attaching antenna bracket to the L-shape bracket ....................................6-52
Attaching tilt guide bracket to the bracket on the antenna ...................... 6-52
Attaching antenna cable to I-BTS ................................................................6-54
Base station connectors ..................................................................................6-55
Ethernet (data) and power connector ..........................................................6-56
Ethernet (data) and power connector ..........................................................6-56
TVS module connector: Base station connector ........................................6-58
TVS module connector: power/Ethernet connector ................................ 6-58
ix
GPS connector ................................................................................................6-59
Serial interface connector ...............................................................................6-60
Base station mounting template ....................................................................6-61
Installing the rackmount base station (RMB)
Cabinet mounting bracket .............................................................................7-69
Location of switch and power supply in rack .............................................7-70
Cell wiring diagram .........................................................................................7-72
Power connections on bottom of cabinet ................................................... 7-74
Grounding the RMBs .....................................................................................7-76
RMB LEDs ...................................................................................................... 7-77
Connector on the serial cable used in configuring base stations ............. 7-78
Diagnostic cable: DB9 connector pins ........................................................7-80
Fuses and Ethernet cable connections on cabinet .....................................7-80
Removing fuse from cabinet ......................................................................... 7-81
External alarm connections ........................................................................... 7-82
Testing and managing the network
GPS status codes
Supported frequency ranges
x Configuring, Installing, and Using Carrier Infrastructure
T
ABLES
About this guide
Chapters and appendices in the guide .............................................. preface-xiv
Additional documentation .................................................................. preface-xv
Typographical conventions ............................................................... preface-xvi
Contacting technical support ........................................................... preface-xvii
Introduction to backhaul installations
Advantages/disadvantages of location choices ............................................ 1-8
Configuring network architecture
Configuring the AP server
Create new ISP page ....................................................................................... 3-23
Configuring a standby AP server
Configuring base stations
Transmit power levels .....................................................................................5-38
Transmit power levels .....................................................................................5-39
Downlink rate based on modulation method ............................................. 5-40
Uplink data rate for 4-QAM modulation method ..................................... 5-40
Uplink data rate for 16-QAM modulation method ................................... 5-40
Uplink data rate for 64-QAM modulation method ................................... 5-40
Uplink data rate for 16-QAM lite modulation method ............................. 5-41
Methods used to grant CPEs access to ISPs’ VLANs .............................. 5-44
Installing the integral base transceiver station (I-BTS)
Ethernet/power base station cable choices ................................................6-57
Ethernet/power cable pins ............................................................................6-57
Function of wires in cable 597-6027-0xxx ..................................................6-57
Recommended mating connectors (optional) .............................................6-59
Installing the rackmount base station (RMB)
Connector type to use with cabinet connectors .........................................7-74
Description of LEDs on the base station ................................................... 7-77
Power cable pins .............................................................................................. 7-79
Diagnostic cable pin connections (RJ-45) ................................................... 7-79
Testing and managing the network
xi
GPS status codes
GPS status codes and meaning .................................................................... A-87
Supported frequency ranges
xii Configuring, Installing, and Using Carrier Infrastructure
Preface overview
Thank you for choosing the Expedience™ system from NextNet Wireless. This guide describes how to configure and install the system’s base transceiver station (BTS) and the rack-mounted base stations system (RMB).
This preface describes:
• Audience for this guide
P REFACE
A
BOUT THIS GUIDE
• Additional documentation
• Typographical conventions used in this guide
• Where to go for more help
About this guide
This guide describes how to configure and install the system’s base station. It also describes how to configure and work with the access provider (AP) server.
This guide is intended for network and system administrators who must install, configure, and manage base stations and the AP server. This guide provides detailed configuration and installation instructions.
It is assumed readers of this guide are familiar with:
• Basic networking concepts
• Layer 2 (link layer) of OSI model
• Cell structure engineering
xiii
Chapters in this guide
Table i describes the chapters and appendices in this guide.
Table i Chapters and appendices in the guide
Chapter Description
Preface Provides an overview of the guide, related documentation,
Chapter 1 Introduction to backhaul installations
Chapter 2 Configuring network architecture
Chapter 3 Configuring the AP server
Chapter 4 Configuring a standby AP server
Chapter 5 Configuring base stations
Chapter 6 Installing the integral base transceiver stations (I-BTS)
Chapter 7 Installing the rackmount base station (RMB)
Chapter 8 Testing and managing the network
Appendix A GPS status codes
Appendix B Supported frequency ranges
the guide’s intended audience, typographical conventions, and methods for obtaining technical support.
Provides an overview of the Expedience system and of the system’s base station component. It provides an installation overview and describes things you need to consider before installing base stations.
Describes a simple network topology and provides an overview of how to configure switches at the cell site, the head end, and the ISP sites.
Describes how to configure and use the access provider (AP) server.
Explains how to configure a standby AP server. The network will use the standby server if the primary server becomes unavailable.
Describes how to configure base stations, including how to use Telnet or Term to set up a base station before deploying it and mounting it to a tower or building. The chapter also describes how to configure base stations after you have deployed them, for example, to maintain the system and optimize system performance.
Explains how to install a base station at a cell site. Also describes the components used to mount the base station on a building or tower.
Describes how to install the rackmount base station (RMB), including installing the cabinet onto a 19 inch rack, installing the power supply and switch, installing the RMB into the base station cabinet and connecting the RMBs to the cell and to cell-site components.
Explains how to work with the ISP to ensure the network is installed and running correctly.
Describes the codes that the GPS can generate.
Provides reference information about the frequency ranges in which the equipment can operate.
xiv Configuring, Installing, and Using Carrier Infrastructure
Additional documentation
If you cannot find the information you need in this guide, you may want to refer to the documents described in Table ii.
Table ii Additional documentation
Guide Description
Getting Started with the Expedience System
Configuring, Installing, and Using Carrier Infrastructure
Using the NextNet Operating System (NNOS)
Configuring and monitoring the ISP network
Expedience Broadband Wireless Access Modem
Installing the RSU Intended for use by your subscribers, this guide describes
Expedience NLOS Outdoor Broadband Wireless Access Modem
Provides an overview of the Expedience system, its components, its network architecture, and options for selecting a deployment scheme for the system in the service provider (backbone) network.
This is the guide you are currently reading. Describes how to set up and configure base stations, including how to connect antenna systems, the backbone network equipment, and global positioning system (GPS) equipment.
Also provides an overview of the AP server and how to configure the AP server for your network.
Describes the NextNet operating system (NNOS), which is the common operating system for the system’s base station devices and customer premise equipment (CPE) devices. This guide describes how you can configure the operating system on devices by using commands issued from Telnet, Terminal, or a Web interface.
Intended for use by an ISP. Provides an overview of the Expedience system, its components, and its network architecture. This guide describes how to install and configure the ISP’s provisioning server. It describes how to define service level agreements (SLAs).
Intended for use by your subscribers, this guide describes how to install a RSU (that is, an indoor CPE) at a subscriber site. Your subscribers can completely install the RSU.
The guide explains, in detail, how to connect the RSU to a computer or to a network device. It explains system pre­requisites, and provides troubleshooting information.
This guide is available in electronic (pdf) format, on the CD-ROM that accompanies the LinkMonitor software.
how to quickly install a RSU directly to a computer.
Intended for use by a professional installer, this guide describes how to install an outdoor CPE.
xv
Typographical conventions this guide uses
Table iii describes the typographical conventions that this guide uses.
Table iii Typographical conventions
Convention Meaning
Bold face If you are using a graphical user interface (GUI), bold face
indicates a button, menu option, icon, and so on, that you manipulate directly.
If you are using a command line interface, bold face indicates commands and keywords.
Bold face can also indicate information that you must enter.
Italic face Arguments for which you supply values are in italic face.
Courier (mono-spaced) font
[ ... ] Arguments that appear inside square brackets [ ], are
{..} | {..} Required keywords are grouped in braces and separated by
Note Notes contain helpful suggestions for the reader.
<...> Non-printing characters, such as passwords, appear in angle
Caution Cautions contain information about which the reader must
Warning Warnings contain information about how readers might do
A command you type in, exactly as it appears, at a command line.
optional. Also, when the guide shows a system prompt, the default
system prompt appears inside square brackets.
vertical bars.
brackets.
exercise care.
something resulting in harm to themselves or in damage to equipment or data.
xvi Configuring, Installing, and Using Carrier Infrastructure
Where to go for more help
This section describes how to obtain support for your NextNet Wireless product. It also describes how to provide comments on the product documentation.
Technical support
NextNet Wireless is committed to providing our customers with high quality technical support. Table iv describes how to contact technical support.
Table iv Contacting technical support
Contact Description
Phone 1.877.962.2200
E-mail support@nextnetwireless.com
Web site www.nextnetwireless.com
Documentation additions and corrections
If you find documentation errors, or want to see additional information not presented in this guide, please contact our documentation group at the following e-mail address:
techdocs@nextnetwireless.com
xvii
xviii Configuring, Installing, and Using Carrier Infrastructure
Chapter overview
This chapter provides an overview of the Expedience system and of the system’s infrastructure components:
• The base station, which comes in two forms:
I
NTRODUCTION
INSTALLATIONS
C HAPTER
1
TO BACKHAUL
• The integral base transceiver station (I-BTS)
• The rackmount base station (RMB)
• The access provider (AP) server
• The network switches
The chapter provides an installation overview. It also describes things you need to consider before installing base stations.
System overview
This section provides a brief overview of the Expedience system, as well as the infrastructure that network access providers must install. For additional system overview information, refer to the guide “Getting Started with the Expedience System.”
System overview
NextNet Wireless designed the Expedience system to give small office, home office (SOHO), and residential subscribers high speed, wireless access to network communication systems, such as the Internet. The Expedience system is an end-to-end broadband wireless access system and operates in several frequency ranges.
The system was designed to allow network access providers to re-sell network bandwidth to ISPs on a wholesale basis. In turn, the ISPs sell access to their subscribers on a retail basis. To support multiple ISPs on the network, the system uses virtual LAN (VLAN) technology.
The system does not CPEs. The air link between base stations and CPEs functions as an Ethernet bridge carrying IP/ARP packets. Time division duplex (TDD) and cellular deployment offer you flexibility in adjusting downlink versus uplink airtime.
have a line-of-sight (LOS) requirement between the base station and the
1-1
Infrastructure overview
The base station and AP server are network infrastructure components supplied by NextNet Wireless. The network access provider configures and maintains this equipment.
Additional infrastructure components include switches for use at the base station cell sites, and the head-end switch. These switches are supplied by the network access provider. If desired, the network access provider can purchase the switches through NextNet Wireless.
Base station overview
The base station maintains contact with CPEs at your subscribers’ sites. The base station integrates the transceiver and modem into one device.
Under typical configurations, the base station covers an approximate radius of 2 to 3 miles, with a 5 mile maximum. If desired, network access providers can configure their base stations to cover a maximum radius of 20 miles. To cover up to 20 miles, the network access provider enables the extended range feature.
There are two types of base stations offered by NextNet Wireless:
• An indoor-only base station that slides into a base station cabinet after the cabinet has been installed on a standard 19 inch rack. This base station is known as the rackmount base station (RMB).
• A base station that can be installed indoors or outdoors. This base station can be installed on a tower, on a roof, on a wall, or on a rack. The antenna can be installed on the base station itself, or the antenna can be installed separately. This base station is known as the integral base transceiver station (I-BTS).
Figure 1.1 shows an individual RMB which will be installed inside a cabinet. This cabinet is then installed on a standard 19 inch rack. Up to 8 RMBs can be installed inside a cabinet.
Figure 1.1 Rackmount base station (RMB)
1-2 Configuring, Installing, and Using Carrier Infrastructure
Figure 1.2 shows 8 RMBs installed inside the base station cabinet.
Figure 1.2 Rackmount base stations inside cabinet
1-3
Figure 1.3 shows a base station that can be installed outdoors or indoors The figure shows the antenna installed on the base station. If desired, you can install the antenna separately from the base station.
Figure 1.3 Base station for indoor or outdoor installation
AP server overview
The AP server acts as a relay for the CPE registration events which arrive from base stations (on the management VLAN) and are forwarded to the correct ISP provisioning server (over the control VLAN).
The base stations each have a TCP/IP connection to the AP server. The base stations use their connection to forward CPE registration requests to the AP server.
The AP server is provided by NextNet Wireless.
1-4 Configuring, Installing, and Using Carrier Infrastructure
Head-end switch, base station cell switch, and ISP switch overview
The network access provider must supply switches for their network, which include the head­end switch and the switches used at the base station cell site. The network access provider must also assist their ISPs when the ISPs program their switches with the proper ISP VLAN IDs.
The base stations are grouped together into cells, with between 1 and 6 base stations at a cell site. (If the network access provider chooses to stack base stations, more than 6 base stations can exist in a cell.) To form the base station LAN, the base stations are connected to a switch at the cell site.
WAN links are then used to connect the cell sites to the head end switch. The head end switch splits incoming traffic to the management VLAN and to the appropriate ISP VLAN. The ISP then has a configured switch that controls traffic coming into and out of the ISP VLANs.
Installation overview
This section provides a high-level overview of how to install the indoor, rackmount base station (RMB), as well as the integral base transciever stations (I-BTS) that can be installed outdoors or indoors.
Installation steps common to RMB and I-BTS
1 Plan the installation of base stations:
a Choose an appropriate location for the base station installation. For more information,
refer to the section “Choosing an installation location” on page 1-7 in this chapter.
b Design the deployment of base stations. Determine how base stations will be deployed
by marking a location on a map that shows where each base station will be installed. Also determine naming conventions for cells, sectors, zones, and base stations names. For more information, refer to the section, “Designing the deployment of base stations” on page 1-10.
2 Plan for system components that you need to supply to complete the network. For more
information, refer to the section “Assessing network access provider equipment needs” on page 1-8 in this chapter.
3 Install and configure the access provider (AP) server. For more information, refer to
Chapter 3, “Installing the AP server,” in this guide.
4 On the AP server, configure zone names, VLAN IDs, and the ISP IDs. For more
information, refer to Chapter 3, “Installing the AP server,” in this guide.
5 Using the NextNet Operating System (NNOS), configure the base stations before
deploying them in the field. For more information, refer to the chapter “Configuring base stations” in this guide.
RMB installation overview
This section provides a high-level overview of how to install the base station cabinet onto a 19 inch rack, and then how to install the base stations into the cabinet.
1 Slide the metal base station cabinet into the 19 inch rack.
2 Install the power supply onto the 19 inch rack.
1-5
3 Install the switch onto the 19 inch rack.
4 Slide each base station into the appropriate slot in the cabinet on the rack.
5 If you are using a 5 watt base station, install the 5 watt channel specific filter.
6 Plug in the cables which include:
• GPS cable
• Antenna cable
• Ethernet cables
• Power cables
• Alarm cables
Also, make sure that the fuses are installed properly.
7 Plug in the power cable to the RMBs in the cabinet, make sure the power supply is
working, then turn on each RMB.
I-BTS installation overview
This section provides a high-level overview of the base station installation process. Other sections in this guide then explain these installation tasks in detail.
The tasks you perform to deploy base stations are:
1 Mount the base station at the site you selected. For more information, refer to the section
“Mounting and grounding the base station” on page 6-57 in this guide.
2 Connect the antenna to the base station, as described in the section “Connecting the
antenna to the base station” on page 6-59.
3 Mount the GPS device and connect it to the base station. One GPS device can service the
multiple base stations at a cell site. For more information, refer to the section “Connecting the GPS equipment to a base station” on page 6-59 in this guide.
4 Connect the base station to the transcient voltage suppressor (TVS) module, then connect
the TVS module to your network switch.
The TVS module splits the connection: one connection goes to a switch that connects to your network, and the other goes to a power supply. For more information, refer to the section “Connecting to the backbone network” on page 6-60 in this guide.
5 Power the base stations by connecting the TVS module to the power supply. For more
information, refer to the section “Powering base stations” on page 6-61 in this guide.
6 Configure cell site switches, the head end switch, and the ISP switches. For more
information, refer to “Configuring switches” on page 2-12 in this guide.
7 Test the network by working with an ISP to:
• Install the ISP’s provisioning server
• Test the AP server to provisioning server connection.
• Test that CPEs can access the ISP’s VLAN(s).
1-6 Configuring, Installing, and Using Carrier Infrastructure
Planning the installation
This section describes issues you need to consider before you install the base stations, including:
• Choosing locations for the base station installation
• Planning for service provider equipment components
• Selection antennas
• Defining naming conventions for cells, sectors, and base stations and for VLANs
Choosing an installation location
The base station’s location at a site depends on many factors, including the site’s physical environment, the coverage pattern you want to achieve, and the ease of maintenance you require.
RMB installation location
The RMB is always installed indoors, inside the base station cabinet and on a standard 19 inch rack. In turn, the rack is installed in an indoor equipment room or in another type of indoor housing unit such as a shed near the tower.
1-7
BTS installation location
Table 1.1 describes some of the locations you might want to consider for a BTS.
Table 1.1 Advantages/disadvantages of location choices
Location Advantages Disadvantages
On tower, at antennas
At base of tower
On rooftop You can use a shorter coaxial cable
Installing at the antennas offers cost savings, due to the fact that you can use a shorter coaxial cable to connect the base stations to your cells. This also offers the ability to transmit at higher power levels, since there is lower signal loss in shorter cables.
Placing the base stations at the base of a tower offers simpler installation and maintenance than a base station installed on the tower, at the antennas.
Base station installation and maintenance are simpler than other options;
to connect base stations to antennas. As such, you can probably operate at higher power levels, and still stay within signal loss criteria.
Rooftop access is usually available, making installation and maintenance easier. Also, a housing unit for the backbone network switch, power supplies, and other equipment is typically available.
When you install base stations near the top of the tower, installation and maintenance are more difficult.
If you install at the base of the tower, you need to run a coaxial cable from the base stations to the antennas. This cable must be of sufficient size to reduce signal loss, which may increase costs.
Installation still requires you to install the antennas and coaxial cable.
You need to obtain permission to use a rooftop, and comply with building codes.
Note: Regardless of the location you choose, plan to provide a weatherproof housing unit for the network switch, the power supply, and the TVS equipment.
Placement of base stations and switches on network
Make sure your network design places the base stations behind a switch so that the base station only sees Ethernet traffic addressed to it. The switch you choose needs to be able to handle the Ethernet traffic on your network
Assessing network access provider equipment needs
Before you install and deploy the base station, ensure you have made provisions for the following components:
• Power and data connection between the base station and your network
• Global position system (GPS) for proper TDD functions. You must use the GPS supplied with the Expedience system.
• Antenna system for transmitting and receiving signals for the base stations.
1-8 Configuring, Installing, and Using Carrier Infrastructure
•SNMP server
• DHCP server, if desired, to supply IP addresses to base stations
• AP server
• Weatherproof housing for the backbone network switch, power supplies, and UPS. Also supply weatherproof housing for the TVS module, which provides lightning protection.
• Coaxial cable to connect the base station to the antenna.
• Tower or building structure on which to mount cell site equipment.
Equipment needs of ISP
As a network access provider, you provide network bandwidth to ISPs. The ISPs in turn sell network access to subscribers. Make sure your ISPs plan for the following pieces of equipment on the ISP VLAN:
•DHCP server
• Customer care server and a customer relationship management application
• Provisioning server
• Switch to receive and direct traffic from the network access provider
• Router to route traffic to the Internet
Planning for the antennas and antenna installation tips
The type of antenna you choose depends on the cell type and pattern you want to use. Make sure:
• The antenna is a high-gain antenna, preferably at least 15dBi or higher.
• The installation of the antenna complies with the vendor’s installation directions, and that it meets building codes.
After you have installed an antenna, you need to connect it to a mounted base station. For instructions on connecting the antenna to a base station, refer to the section “Connecting the antenna to the base station” on page 6-59.
1-9
Designing the deployment of base stations
To plan for how base stations will be deployed:
1 Determine a naming convention for base stations.
2 Using a map of the area to be covered, define the zone names that will be used.
For example, an access provider can divide a metropolitan areas into North, South, East, West, and Central zones. The network access provider then assigns base stations to a specific zone by using the set system location command. Keep in mind that multiple base stations may be assigned to the same zone. Zones allow the ISPs to differentiate services to subscribers by allowing subscribers to operate in specific regions or clusters of zones.
3 On a map, mark each location where base stations are installed.
4 For each base station, document your design choices. Please note that some parameters are
optional, depending on how you design the system.
• Base station name (required)
• Zone name (required)
• Cell name (optional)
• Sector name (optional)
•Channel (required)
• Default VLAN for legacy CPEs (optional, default is 1)
• Management VLAN ID (optional; default ID is 1)
1-10 Configuring, Installing, and Using Carrier Infrastructure
C
ONFIGURING
Chapter overview
This chapter describes a simple network topology. It provides an overview of how to configure switches at the cell site, the head end, and the ISP sites.
Architecture overview
C HAPTER
2
NETWORK ARCHITECTURE
The hierarchy of the network architecture uses the concept of two layers: the access layer and the backbone layer.
The functions of the access layer include connecting users — which include subscribers and the ISPs — to the backbone layer.
Subscribers use components on the access layer (the CPEs and the base stations) to obtain broadband network services. The subscriber’s CPE communicates with a base station over a radio link which is commonly called the air link. The base stations that communicate with the CPEs are grouped into cells. The base stations in each cell are connected to a switch at the cell site and a base station LAN is formed. The switches at the cell sites then use WAN links to connect to the head-end switch.
The ISPs also use the access layer to connect to the backbone layer. An ISP receives network access requests from components on the backbone layer (specifically the AP server on the management VLAN). These requests for access are sent to the appropriate ISP. The ISP then grants or denies the request. If access is granted, the ISP provides the subscriber’s host computer with an IP address and traffic is shaped for that host computer according to the subscriber’s service level agreement (SLA). Traffic to and from the host computer travels through the backbone layer
The functions of the backbone layer include quickly switching incoming WAN trunk traffic to the management VLAN and to the ISP VLANs. The backbone layer also returns Internet traffic from the ISP to the appropriate base station and subscriber’s CPE.
2-11
Configuring switches
This section describes configuration of the following switches:
• Switch connecting base stations at the cell site
• Head end switch
• ISP switch
Configuring the switch at the cell site
At the cell site, the network access provider must program a port on the switch to be a WAN trunk to the head end switch.
Configuring the head end switch
WAN trunk ports on the head end switch must be configured to accept traffic from the cell sites.
The head end switch then splits the traffic to the Management VLAN and the ISP VLANs. The network access provider configures edge ports on the head end switch with the Management VLAN ID, and the IDs of all the ISP VLANs.
Configuring the ISP switch
The ISP switch must be configured with the IDs of VLANs provided to the ISP by the network access provider. A port on the switch is also configured with the ID of the control VLAN.
Selecting links and circuits
Network access providers must select the links or circuits that connect the cells to the backbone network. Each cell may have one or more base stations, and each base station serves a sector within a cell. Service providers typically deploy cells in four or six sectors.
Downlink and uplink capacities are:
• For downlink, the base station capacity ranges from 1.364 to 3.198 Mbps.
• For uplink, the capacity ranges from 1,249 to 198 Kbps.
Typically, you adjust the downlink air time to be some multiple of the bandwidth of the uplink. This is because browsing requests from your subscribers will most likely be shorter than responses. Therefore, as an example, you can configure a base station for a capacity of
3.030 Mbps downlink, and 296 Kbps uplink.
Some commonly used link types to backhaul cell traffic are DS-3 and point-to-point microwave connections.
Selecting links based on maximum rate needed
You can choose a link based on the maximum bit-transfer rate you might need. For example, you might use DS-3 circuits to connect cells to a switch, and then connect those switches together, using the appropriate higher-rate links.
2-12 Configuring, Installing, and Using Carrier Infrastructure
Selecting links based on another rate
You might want to choose a link providing another data transfer rate. The link you choose might depend on the expected and actual traffic rates for a given cell.
Choosing this option means you get lower cost circuits, but you also might get lower throughput, increased response time, and so on.
2-13
2-14 Configuring, Installing, and Using Carrier Infrastructure
C
HAPTER
3
C
Chapter overview
This chapter describes how to configure and use the access provider (AP) server.
AP server overview
ONFIGURING
THE
C HAPTER
3
AP
SERVER
All base stations connect to the AP server using a TCP/IP session. Using this connection, the base stations transfer incoming registration requests from CPEs to the AP server. The AP server forwards the request to the proper provisioning server for authorization.
The AP server defines the zones and ISPs that comprise network access provider’s network.
Note the following about the AP server:
• The connection between the AP server and the provisioning server is always established from the AP server to the server. Network access providers or ISPs cannot use the provisioning server to define or attempt a connection back to the AP server.
• The AP server does NOT accept CPE registrations from base stations that do not have a zone setting that the AP server can recognize.
Starting the AP server
The AP server was designed to use a Java servlet called Tomcat.
1 To run the Tomcat server, type the following at a command prompt:
net start tomcat
2 To stop the Tomcat server: type the following at a command prompt:
net stop tomcat
3 To verify that the server is installed correctly, open an Internet browser. In the browser’s
address field, type the following address:
http://localhost:8080/ap
3-15
Configuring the AP server
To configure the AP server, you must define AP server users, configure zone names, VLAN IDs, ISP names, and ISP IDs.
Defining AP server users and administrators
To define users and administrators of the AP server:
1 Open a web browser. In the browser’s address field, type the address of the AP server.
A log in page appears.
Figure 3.1 AP server log in page
4.0.0
If you are logging into the server for the first time, log in with the following defaults:
• User name: administrator
• Password: password
If you are logging in for the second or subsequent time, enter your user name and password in the appropriate fields.
3-16 Configuring, Installing, and Using Carrier Infrastructure
The Access Provider Management page opens.
Figure 3.2 Access Provider Management page
4.0.0
MK
3-17
2 From the Access Provider Management page, click the Configure link. The Configure
page opens.
Figure 3.3 Configure page
4.0.0
MK
3-18 Configuring, Installing, and Using Carrier Infrastructure
3
From the Configure page, click Administrators.The Administrators page opens.
Figure 3.4 Administrators page
Norman
Tyra
Jen
Juan
4.0.0
MK
4 In the Changes on this page require your password here: field, type your password.
3-19
5 Click Create New User. The New User page opens.
Figure 3.5 New User page
4.0.0
MK
6 In the Changes on this page require your password here: field, type your password.
7 Complete the fields on the page, then click Save Changes.
3-20 Configuring, Installing, and Using Carrier Infrastructure
Defining zone names
To define zone names:
1 From the AP server’s home page, click Configure.
2 From the Configure page, click the Base Station Configuration link.
Figure 3.6 Base Station Attributes page
4.0.0
CityCentral
CityNorth
CitySouth
CityEast
CityWest
MK
3 In the Enter new zones below, comma separated field, type the names of base station
zones. Use commas to separate names.
4 For load balancing purposes, you can enter limits on the amount of traffic that a base
station can handle on both the uplink and downlink. If a CPE tries to register with a base station when either of the limits are met, the CPE will receive a notice that it should try to register with another, less busy base station. If no such base station is available, the CPE registers with the first base station.
• To specify the limit of uplink traffic that a base station can handle before the base
stations indicates to registering CPEs to look for another base station, in the Uplink Base Threshold field, type the limit.
• To specify the limit of downlink traffic that a base station can handle before the base
station indicates to registering CPEs to look for another base station, in the Downlink Base Threshold field, type the limit.
5 To specify the maximum number of VoIP calls that a base station can handle, in the Max
VoIP calls per Base field, type the limit.
6 Click Save Zone Changes. The new zone names appear in the Zone column.
3-21
Registering with the AP server after Zones defined
After you define zones, the base stations must re-register with the AP server so that the AP server recognizes the base station as having a correct zone.
To re-register the base station with the AP server:
1 Establish a terminal session with the base station.
a From the Base Station Properties page (see Figure 3.11), click on the IP address of the
base station.
b A terminal session starts, where you can log in to the NNOS.
2 To assign the base station to zone, use the NNOS command “set system location”. This
generates a base station registration record.
3 To save the settings on the base station, type write. The change is written to Flash memory
on the base station.
4 Close the terminal session.
5 To verify that the base station’s zone name is correct, refresh the web browser.
Defining ISPs
To define ISPs:
1 From the AP server’s home page, click Configure.
2 On the Configure page, click the ISP Management link.
Figure 3.7 ISP Management page
4.0.0
MK
174.192.047.1
174.167.123.1
3-22 Configuring, Installing, and Using Carrier Infrastructure
3
To add a new ISP, click the Add ISP button.The Create new ISP page opens.
Figure 3.8 Create new ISP page
Table 3.1 describes the fields on the Create new ISP page that access providers must complete to add ISPs.
Table 3.1 Create new ISP page
Field Description
ISP Name A name for the ISP
Billing Record Time The time of day when the provisioning server is polled for billing
information. This information includes the number of CPEs that are assigned to a service level agreement.
IP address IP address of the ISP provisioning server
VLANs ID numbers of the VLANs assigned to the ISP
Mfg Tags An embedded number on the CPE that determines which Internet
Service Provider (ISP) owns the CPE device
3-23
Changing ISP information
To change the information about the ISP:
1 From the ISP Management page, click the link of the name of the ISP whose information
you want to change.
Figure 3.9 ISP details page
2 Alter the fields on the page as desired. Click Save Changes.
3-24 Configuring, Installing, and Using Carrier Infrastructure
Monitoring ISPs and base stations
Using the AP server, you can view information about the status of ISPs and base stations that are part of the network access provider network.
To view information about ISPs and base stations:
1 From the AP server home page, click Monitor. The Monitor ISPs - Base Stations page
opens.
Figure 3.10 Monitor ISPs- Base Stations page
Cell1Sector1
Cell1Sector2
Cell1Sector4
CityCentral
CityCentral
CityNorth
4.0.0
MK
3-25
2 To start a terminal session with the base station, and change the base station’s parameters
using the NextNet Operating System (NNOS), click the name of the base station.The Base Station Properties page opens.
Figure 3.11 Base Station Properties page
4.0.0
CityCentralS1C2
12
153.149.100.54
3 Click the IP address. A terminal session starts with the base station.
MK
For more information about changing NNOS parameters on base stations, refer to the guide “Using the NextNet Operating System (NNOS), Version 2.”
3-26 Configuring, Installing, and Using Carrier Infrastructure
C
HAPTER
4
C
ONFIGURING
A
Chapter overview
This chapter describes how to configure a standby AP server. The network will use the standby server if the primary server becomes unavailable.
Standby AP server overview
STANDBY
AP
C HAPTER
4
SERVER
The standby AP server can be put into service if the primary AP server is not available.
Note: Make sure that the primary and secondary server are not running at the same time. Also, make sure that the server on which shared AP configuration files reside is not powered off while either the primary or secondary server is running.
During AP server outage, subscriber data traffic is passed from CPEs and VLANs.
The elements of the standby AP server solution are:
• Primary AP server
• Secondary AP server
• Shared AP server configuration files
To maintain overall network integrity, configure the primary and secondary AP server with identical information, including the ISP ID assignments and VLAN assignments.
Configuring the base station with standby AP server information
To configure the base station so it can use a standby AP server:
1 Set the address of the primary and secondary server:
set aaa server address p.p.p.p,s.s.s.s
where:
p.p.p.p is the address of the primary AP server.
s.s.s.s is the IP address of the secondary AP server.
4-27
2 To save the changes to Flash memory, type the following:
write
3 To make sure the setting is correct, type:
show aaa
The following information appears:
aaa authority => remote
aaa cache => enabled
aaa port => 12541
aaa server address => 000.111.222.333 999.888.777.666
Note: 000.111.222.333 999.888.777.666 represent the IP addresses of the primary and secondary AP server respectively.
aaa state => enabled
Setting up common configuration file and directory
This section describes how to set up a common configuration directory on a shared network drive.
After the AP server software is in installed, the following directories exist:
• NextNetHome
• NextNetConfigFolder
The NextNetConfigFolder contains the following configuration files which need to be shared between the primary and secondary AP servers.
Figure 4.1 Configuration files to share between primary and secondary AP servers
File Description
nextnet.properties Specifies application parameters and the location of billing record folder
ap_logging.properties Specifies the location of audit logs and application logs. Also lists logging
parameters
users.xml A list of user names
isps.xml A list of ISPs
zones.xml A list of zone names
Create a shared directory on a server that stores these files. This shared directory can reside on either the primary or secondary server, if desired.
To create a shared directory:
1 Create the shared directory on the chosen machine:
\\ConfigServer\nn\config
2 Create a user called TomcatServiceUser. Set permissions on the shared directory to
grant all privileges to the user.
3 On both the primary and secondary servers, set up the same user name:
TomcatServiceUser
This user ID is used to run the Tomcat service. The ID must have permission from both primary and secondary AP servers to access the shared directory on the ConfigServer.
4-28 Configuring, Installing, and Using Carrier Infrastructure
This user should be a member of the group users. The user name and password must match the user account and password on the ConfigServer.
4 Install the AP server using the standard installation program. When the installation
program prompts you:
a Place the NextNetHomedirectory on a local drive.
b Specify that the NextNetConfigFolder resides on the remote share.
5 On the primary and secondary servers, specify that the Tomcat service logs on as
TomcatServiceUser:
aFrom the Start menu, select Settings, Control Panel, Administrative Tools. From
the list of items that appears, select Services. The Services window opens.
b Double click on the Tomcat service. A Properties window for the service opens.
c Click the Log On tab.
dIn the This Account: field, type the account name. In the Password: and Confirm
Password: fields, type the password of the user account.
6 On the primary AP server, specify the startup type as Automatic.
7 On the secondary AP server specify the startup type as Manual.
8 Click on the General tab, and specify the following:
a For the primary AP server, from the Startup type drop down list box, select
Automatic.
b For the secondary AP server, from Startup type the drop down list box, select
Manual.
Testing the installation
To test the installation:
1 From a command prompt, type:
net start Tomcat
If the service starts correctly, the Administrative Tools/Event Viewer shows that the service started.
2 Reboot the AP server. Without being logged on, you should be able to browse to the AP
web application from another machine.
Location of audit files and log files
Directories within the NextNetConfigFolder directory contain the audit logs and application logs. If you configured a shared space on a network directory for the primary and secondary AP server, the log files will be stored in the shared directory named NextNetConfigFolder.
If you have turned on the feature than enables debugging information to be written to a file, note that the performance of the AP server might degrade, as the server might be saving a lot of information to a network drive.
If desired, you can configure a different location where the files can be stored, such as C:/nn/logs.
4-29
Switching from the primary AP server to the secondary AP server
To switch from the primary AP server to the secondary AP server:
1 Stop the primary AP server. To do so, from a command prompt on the primary AP server,
type:
net stop Tomcat
2 Start the secondary AP server. To do so, from a command prompt on the secondary AP
server, type:
net start Tomcat
After the primary server is stopped, each base station automatically detects the loss of the primary connection. The base station then attempts to connect with the secondary AP server.
The secondary server connects to the ISP provisioning servers. Since this connection overrides any previous connection with the provisioning servers, you must stop the primary AP server before starting the secondary AP server.
4-30 Configuring, Installing, and Using Carrier Infrastructure
Chapter overview
This chapter describes how to configure base stations. It describes:
• How to configure the base station so you can communicate with the base station using a term connection, an SNMP connection, a web connection, and a Telnet connection
• The operating system parameters to configure before you deploy base stations
C
HAPTER
5
C
ONFIGURING
C HAPTER
5
BASE STATIONS
• How to set up a system component (called an “authority”) that grants CPEs access to your network
Before you begin
To configure base stations before you deploy them on towers or buildings, you must first supply power to the base station, and connect the base station to a PC using the serial cable/ serial connection. To perform these tasks:
1 Place an RF 50 ohm load or at least a 10dB RF attenuator on the RF connector. The load
or attenuator must be capable of 10 watts of dissipation.
2 Connect the base station to the TVS module by plugging the provided cable into the left-
most connector on the bottom of the base station. Then, plug the TVS module into a power source.
3 Use the serial interface cable to connect your computer to the base station.
4 On your computer, set up terminal emulation access to the base station, as described in the
section “Setting up terminal emulation access” on page 5-32 in this guide.
5 If you have not already done so, start a terminal emulation session with the base station
you want to configure and log on to NNOS. (If you are using a Windows operating system, you may want to use the Hyperterminal application to open the connection defined in step 4.)
6 Configure the base station as described in the following sections of this chapter:
• “Setting base station configuration parameters” on page 5-37
• “Recommended parameter changes” on page 5-42
• “Setting up Syslog” on page 5-43
• “Configuring the authority that grants network access to CPEs” on page 5-44
• “Configuring the time signal used by base stations” on page 5-46
5-31
Setting up connection methods used to configure base stations
The Expedience system allows you to connect to a base station using many methods:
• Terminal emulation over a serial line
•Telnet
•Web server
•SNMP server
Before you can use a particular method to connect to the base station, you must configure its connection.
To configure the base station initially, you will most likely use a serial connection and a terminal emulation session. Terminal emulation allows access through a direct RS-232 connection from a personal computer to the base station.
Setting up terminal emulation access
The terminal emulation connection is a physical RS-232 cable connection, between the base station and a PC. Once the connection is set up, you can use a program—such as Hyperterminal under the Windows operating system—to configure and communicate with the base station.
Terminal emulation connection settings
To set up a terminal emulation connection, use these settings:
• 19.2k baud
• 8 data bits
•No parity
• 1 stop bit
• no flow control
Setting up Telnet access
To set up your system to use Telnet to access a base station:
1 Using your Term connection, at the NNOS command prompt, issue the following
command to enable Telnet:
set telnet state enabled
2 If you want to change the default port on which the Telnet server listens:
set telnet port
The factory default is 23.
{portnumber}
5-32 Configuring, Installing, and Using Carrier Infrastructure
3
To set the IP address, or range of IP addresses, of the remote computers that are allowed to use Telnet to access the base station:
set telnet remote
{IPaddress | IPaddress mask}
where:
IPaddress is the IP address of the computer that is allowed to use Telnet to access the base station.
IPaddress mask is a mask for a range IP addresses that are allowed to use Telnet to access the base station.
4 If you want to change the Telnet timeout from the factory default of 5 minutes:
set telnet timeout
{time}
where {time} is the time, in seconds, that the Telnet session is allowed to sit idle before the session ends.
5 Before you can telnet to the base station, you need to set the base station’s IP address.
a To set the base station’s IP address, at a NNOS prompt, type:
set IP address
{IPaddress}
where:
IPaddress is the IP address of the base station.
b To determine the base station’s address, use Terminal emulation over a serial line
connection to the base station. At a term connection’s NNOS prompt:
show IP address
Remember the base station’s IP address. You will need it later if you want to use Telnet a web browser, or SNMP session to configure or monitor the base station.
Note: If you have assigned names to your base stations, you can also use the “show name” command to determine the base station’s name. Then, you can telnet to the base station using its name. For further information, refer to the section “Recommended parameter changes” on page 5-42 in this guide.
6 For changed settings to take effect, you must write the changes to Flash memory and then
restart the base station.
a At the NNOS command prompt, type
b At the next NNOS command prompt, type
write
.
reboot
.
5-33
Setting up web access
This section describes how to set up your base station for web access.
Note: To determine how parameters are currently configured, you can issue a “show” command for the parameter you want to check. For example, a “show web state” command will tell you if the base station already has the web server enabled. Most of the system’s default settings for parameters will help ensure your base station is ready for web access when the factory ships the base station.
To set up your system for web access:
1 Using your Term connection, at the NNOS command prompt, issue the following
command to enable the web server:
set web state enabled
2 To change the default web port number:
set web port
The default port number is 80.
3 To specify the IP address of the remote computer or computers allowed to access the web
server on the Expedience device, specify a mask appropriate to your network. Type the following command:
{port number}
set web remote
{IPaddress | IPaddress mask}
where:
IPaddress is the address of the computer that is allowed to access the web server on the base station.
IPaddress mask is a mask for a range of all IP addresses that are allowed to access the base station web server.
4 If you changed the settings for the set web state or the set web port parameters, write
your changes to memory and then restart the base station.
a At the NNOS command prompt, type
b At the next NNOS command prompt, type
5 Open an Internet browser. In the address field, access the web server on the base station
write
.
reboot
.
by typing the IP address of the base station.
6 A user name and password window appears.
a If you want to be able to change configuration parameters, type the super user
password.
b If you only want to be able to view configuration parameters, type the user password.
c If you don’t know the password, contact your system administrator.
5-34 Configuring, Installing, and Using Carrier Infrastructure
Setting up SNMP access
This section describes how to set up your base station for SNMP access.
Note: To determine how parameters are currently configured, issue a “show” command for the parameter you want to check. For example, a “show snmp state” command will tell you if the base station already has the SNMP agent enabled. Most of the system’s default settings for parameters will help ensure your base station is ready for SNMP access when the factory ships the base station.
To setup your system for SNMP access:
1 Using a Term or telnet connection, at the NNOS command prompt, issue the following
command to enable SNMP:
set snmp state enabled
2 To specify the IP address of the remote computer or computers allowed to access the
SNMP server on the base station, specify a mask appropriate to your network. Type the following command:
set snmp remote
{IPaddress | IPaddress mask}
where:
IPaddress is the address of the remote machine that is allowed to access the SNMP server.
IPaddress mask is a mask for a range of all IP addresses that are allowed to access the base
station’s SNMP server.
3 If you want to use SNMP traps:
set snmp traps enabled
4 To specify the IP address of the SNMP trap server on the network management
workstation:
set snmp trap server
{IPaddress}
where {IPaddress} is the IP address of the machine to receive SNMP traps.
5 Specify the trap level for the functions whose traps can be reported. To specify the level of
the SNMP trap messages that are sent to the trap server:
set snmp
{function}
traplevel
{variable}
where:
{function} is the feature whose trap level you want to set. Functions you can specify include
airlink, config, nnmgr, reg mgr, relay
{variable} is the trap level, with a value of
, and
0, 3, 4, 5
stack
.
, or 7.
For more information, refer to the guide “Using the NextNet Operating System (NNOS).”
5-35
6 Specify the SNMP community name. A community is a logical relationship between an
SNMP agent and one or more SNMP managers. The community has a name, and all members of a community have the same access privileges.
To specify the community that will have read privileges:
set snmp read community
{name}
To specify the community that will have write privileges:
set snmp write community
{name}
For both parameters, {name} specifies the name of the community.
7 To allow the ability to configure parameters through SNMP access:
set snmp access enabled
8 If you changed the settings for the set snmp state, write your changes to Flash memory
and then restart the base station.
a At the NNOS command prompt, type
b At the next NNOS command prompt, type
write
.
reboot
.
Configuring SNMPc 5.0 for use with Expedience base stations
If you are using the network management application SNMPc 5.0 from Castle Rock, change the default community name of base stations.
1 Open the SNMPc 5.0 application and select a base station.
2 Within the application, use the set community command to set the base station’s
community name to “public”.
Note: The default community name is netman.
3 Repeat step 2 for each base station you want to manage.
5-36 Configuring, Installing, and Using Carrier Infrastructure
Setting base station configuration parameters
This section describes configuration parameters to set for proper base station operation.
You can use terminal emulation, Telnet, the web interface, or an SNMP session to configure the parameters on the base station.Before you can use these methods, make sure the connection is set up. For further information, refer to the section “Setting up connection methods used to configure base stations” on page 5-32 in this guide.
To set up the base station:
1 Set the following parameters, in the order that follows:
• set airlink channel, as described on page 5-37 in this guide.
• set airlink downlink power, as described on page 5-38 in this guide.
• set airlink downlink bias, as described on page 5-39 in this guide.
• set vlan legacy id, as described on page 5-43 in this guide.
• set vlan mgmt id, as described on page 5-43 in this guide.
• set airlink state, as described on page 5-42 in this guide.
For more information about these configuration parameters, as well as a full list of configuration parameters, refer to the guide “Using the NextNet Operating System.”
2 After setting the parameters, use the write command to write the settings into the flash,
non-volatile memory.
3 For changes to take effect, perform one of the following:
• Re-boot the base station
—OR—
• Power down the base station, and then re-power it.
set airlink channel
Set this configuration parameter to the frequency channel on which to run the airlink. For an illustration of the channels that are supported in the various frequency ranges, refer to Appendix B.
Example: set airlink channel 15
5-37
set airlink downlink power
This parameter specifies the base station’s transmit power level.
The power levels you can specify depend on the type of base station you are using: a 2 watt base station, or a 5 watt base station.
2 watt base station
Specify a power value from 10 to 31.
The maximum system power level is 10, which specifies +33 dBm (2 watts). The other power levels are measured in 1 dB steps from the maximum.
Example:
Table 5.1 Transmit power levels
Power value Power level
10 +33 dBm = 2.0 watts
. .
13 +30 dBm = 1.0 watt
. .
16 +27 dBm = 500 milliwatts
. .
23 +20 dBm = 100 milliwatts
. .
31 +12 dBm = 15.8 milliwatts
set airlink downlink power 10
5-38 Configuring, Installing, and Using Carrier Infrastructure
5 watt base station
Specify a power value from 6 to 31. The maximum system power level is 6, which specifies +37 dBm (5 watts) at the RF connector. The other power levels are measured in 1 dB steps from the maximum.
To operate the base station at the 5 watt level, you must install a supplied channel filter.
Example:
Table 5.2 Transmit power levels
Power value Power level
set airlink downlink power 10
6 +37 dBm = 5 watts
. .
10 +33 dBm = 2.0 watts
. .
13 +30 dBm = 1.0 watt
. .
16 +27 dBm = 500 milliwatts
. .
23 +20 dBm = 100 milliwatts
. .
31 +12 dBm = 15.8 milliwatts
set airlink downlink bias
This parameter specifies the portion of airtime (slots) available for use on the downlink relative to the airtime for the uplink. There are always 6 slots available for the uplink.
The higher the bias, the more bandwidth is available for the downlink, due to more time allocated to the downlink.
Example: set airlink downlink bias 2
You must specify the same downlink bias for all base stations in a cell. Likewise, all base stations within your system, regardless of the cell they are in, must have the same downlink bias.
Note: If you are using both 4-QAM only RSUs and AMOD RSUs, do NOT use bias 1.
5-39
Table 5.3 describes the downlink rates for various modulation methods.
Table 5.3 Downlink rate based on modulation method
4-QAM 16-QAM 64-QAM 16-QAM lite
Bias Downlink rate Downlink rate Downlink rate Downlink rate
0 1,337,358 2,100,580 2,863,803 3,627,025
1 1,719,413 2,975,037 4,230,661 5,486,284
2 2,127,308 3,906,987 5,686,667 7,466,347
3 2,294,515 4,288,741 6,282,967 ---
4 2,424,466 4,587,929 6,750,392 ---
5 2,530,766 4,828,640 7,126,514 ---
Table 5.4 describes the uplink data rate when QPSK is the modulation method.
Table 5.4 Uplink data rate for 4-QAM modulation method
Bias Uplink all 1 slot 2 slot
0 1,314,152 210,264 431,545
1 1,080,996 172,959 354,981
2 835,728 133,716 274,439
3 735,804 117,729 241,625
4 657,076 105,132 215,772
5 593,488 94,958 194,891
Table 5.5 describes the uplink data rate when 16-QAM is the modulation method.
Table 5.5 Uplink data rate for 16-QAM modulation method
Bias Uplink all 1 slot 2 slot
0 2,867,241 438,051 926,489
1 2,358,537 360,332 762,112
2 1,823,407 278,576 589,196
3 1,605,391 245,268 518,749
4 1,433,620 219,025 463,245
5 1,294,883 197,829 418,415
Table 5.6 describes the uplink data rate when 64-QAM is the modulation method.
Table 5.6 Uplink data rate for 64-QAM modulation method
Bias Uplink all 1 slot 2 slot
0 3,942,456 584,068 1,260,876
1 3,242,988 480,443 1,037,172
2 2,507,184 371,435 801,847
3 2,207,412 327,024 705,974
4 1,971,228 292,034 630,438
5 1,780,464 263,772 569,428
5-40 Configuring, Installing, and Using Carrier Infrastructure
Table 5.7 describes the uplink data rate when 16 QAM lite is the modulation method
Table 5.7 Uplink data rate for 16-QAM lite modulation method
Bias Uplink all 1 slot 2 slot
0 5,256,608 750,944 1,661,571
1 4,323,964 617,712 1,366,777
2 3,342,912 477,559 1,056,668
3 --- --- ---
4 --- --- ---
5 --- --- ---
set system location
This parameter defines the zone to which the base station belongs.
During the design of the network, the access provider defines zones of coverage for the network. For example, an access provider can divide a metropolitan areas into North, South, East, West, and Central zones.
In the North zone, the network access provider decides to install three base station cells. All base stations in this zone—regardless of their cell assignment—have the same zone name of North.
The network access provider then assigns base stations to a specific zone by using the set system location command.
Example: set system location North
5-41
set system name
The parameter specifies the name of the base station.
For example, the network access provider has three base station cells in the zone called North. All base stations in this zone—regardless of their cell assignment—have the same zone name: North.
Using the system name, the network access provider provides a name for each base station. This system name reflects where the base station is installed in the North zone.
To continue the example, a base station assigned the zone name of “North” is to be installed near the intersection of 7th street and Randolph avenue. The base station is given the name sevenandrandolphbase2. This name indicates that this is the second base station installed near the street. Another base station (also in the North zone) is to be installed near the intersection of Carmody drive and 45th avenue. It is given the name carmodyand45base1.
Example: set system name SevenandRandolphBase2
set airlink state
This parameter enables the airlink.
After you specify the set airlink channel number, set airlink downlink power, and set downlink bias parameters, set the airlink state to enabled, so changes can take effect.
Example: set airlink state enabled
You can take the base station off the air by disabling the airlink.
Recommended parameter changes
Before deploying a base station, it is recommended that you assign the base station a cell name and a sector name.
set system cell
This parameter specifies the cell name in which the base station is installed.
Example: set system cell RiverBendRoad
set system sector
This parameter specifies the sector in which the base station is installed.
Example: set system sector north
set DHCP state
If you want to use a DHCP server to assign IP addresses to base stations, set this parameter to enabled.
Example: set DHCP state enabled
5-42 Configuring, Installing, and Using Carrier Infrastructure
Setting legacy and management VLAN IDs
When the base station is shipped from the factory, the identification numbers for the legacy VLAN and for the management VLAN are both set to 1.
If you or your ISPs use only CPEs that run Version 2.x software code or later, you do not need to change the default id for either VLAN.
However, if you have some CPEs running version 1.x code, you need to set up a legacy VLAN with an identification number different from the management VLAN ID. The legacy VLAN then services all CPEs that run version 1.x software code.
set vlan legacy id
This command specifies the identification number for all legacy CPEs—CPEs that run version 1.x software code. Make sure the legacy VLAN configuration setting is identical on all base stations in the network.
Example: set vlan legacy id 4
set vlan mgmt id
This command specifies the identification of the management VLAN. The management VLAN is used for network management. It also handles authorization protocol messages. All base stations attach to the management VLAN. A network access provider must have one management VLAN. The VLAN identification number must be the same number on all base stations in the network.
Example: set vlan mgmt id 1
Setting up Syslog
This section describes how to set up Syslog options. Syslog is a tool that records operational data, unusual system occurrences, system commands, and messages. To set up your system’s Syslog options:
1 To enable Syslog, use a command line interface run over the network (such as telnet) or
use a serial line connection to the base station.
2 If you have not already done so, log on to NNOS. At the NNOS command prompt, issue
the following command to enable Syslog:
set syslog state enabled
3 Specify the level for the functions whose syslog events can be reported. To specify the
level of the messages:
set syslog
where:
{function} is the feature whose level you want to set. Functions you can specify include
airlink, config, nnmgr, reg mgr
{variable} is the level, with a value of
For further information about the functions and Syslog levels, refer to the guide “Using the NextNet Operating System (NNOS).”
{function}
level
{variable}
, and
relay
.
0, 3, 4, 5
, or 7.
4 To set the Syslog port number:
set syslog port 514
5-43
5 Set the Syslog server to the address of the network management workstation
set syslog server
where {IPaddress} is the address of the workstation that is running the Syslog application.
6 To verify the operation of Syslog, open the Syslog server, where you can view messages or
create Syslog message reports.
{IPaddress}
Configuring the authority that grants network access to CPEs
This section describes how to set up a system component (called an authority) that grants CPEs the ability to access the ISPs’ VLANs.
Table 5.8 describes the methods the network can use to grant network access to CPEs.
Table 5.8 Methods used to grant CPEs access to ISPs’ VLANs
Type of authority Description
Remote authority The ISP’s provisioning server resides on the ISP VLAN and is
used to grant network access to CPEs. When the base station is configured to use remote authority, the
CPE’s network access request travels to the base station. The base station then forwards the request to the network access provider’s AP server. The AP server relays the request to the proper ISP and the provisioning server.
The provisioning server is checked to ensure the CPE is allowed to access the ISP’s VLAN. If so, the provisioning server sends a record that grants access back to the base station.
Local authority The base station grants network access to CPEs. When this type
of authority is used, all CPEs are placed on the same VLAN, which is the legacy VLAN.
Note: The AP server, which acts to relay CPE service requests to the proper ISP VLAN, is sometimes referred to as an AAA (“authentication authorization accounting” or “triple A”) server.
Using base station caching feature for re-registering CPEs
Network access providers can also set up the base station to grant access to CPEs that have already been granted permission to operate on the network. When a CPE re-registers, the base station uses the existing parameters stored on the base station, such as the CPE’s VLAN assignment and the number of hosts the CPE is allowed to service. For more information on this feature, refer to “set aaa cache” in the guide “Using the NextNet Operating System (NNOS).”
5-44 Configuring, Installing, and Using Carrier Infrastructure
Remote authority: setting up the provisioning server to grant CPEs network access
Under remote authority the provisioning server grants CPEs network access. All requests for access are relayed to the appropriate ISP through the network access provider’s AP server.
To set up remote authority:
1 Contact the appropriate ISP to make sure the provisioning server hardware and software
are properly installed.
2 Add appropriate routes to the base station’s routing table.
Use the NNOS “route add” command to add a route (from the base station to the AP server), and a reverse route (from the AP server to the base station) to the base station’s route table.
Note: Steps 3 through 6 help you configure the base station to use the AP server as a relay for CPE registration requests. The AP server forwards the registration requests to the appropriate provisioning server. To complete these steps, use Terminal emulation and a serial line connection to the base station. You can also use Telnet, SNMP, or web access if access for these connection methods is configured.
3 To specify the address of the AP server that receives records:
set aaa server address
{IPaddress1},{IPaddress2}
where
{IPaddress1} is the address of the workstation that runs the AP server.
{IPaddress2} is the address of a redundant workstation that runs the AP server if the workstation identified by IPaddress1 goes down. Control returns to the workstation identified by IPaddress1 when the redundant workstation goes down.
4 To specify the port on which the AP server listens:
set aaa port 12451
5 Configure the method the base station uses to grant network access to CPEs:
set aaa authority remote
where
remote
indicates the provisioning server (through the AP server relay) grants
network access to CPEs that are attempting to connect to the network.
6 To activate the AP server feature:
set aaa server enabled
7 To store the changes in Flash memory:
write
5-45
Local authority: setting up the base station to grant CPEs network access
If you establish local authority, the base station always grants CPEs network access. All CPEs are placed on the same VLAN, which is the legacy VLAN.
To set up local authority:
1 Disable the AAA server feature:
set aaa state disabled
2 Configure the method the base station will use to grant network access to CPEs:
set aaa authority local
where
local
indicates the base station grants access to CPEs that want to connect to your
network.
3 To store the changes in Flash memory:
write
4 Reboot the base station. When the CPEs re-register with the base station, the base station
places them on the legacy VLAN.
Configuring the time signal used by base stations
Expedience base stations require a time synchronization signal in order to determine the proper timing for time division duplexing (TDD).
Because most Expedience system deployments use multiple base stations, at multiple cell sites, most service providers will configure their base stations to use the time synchronization signal generated by the Expedience system’s global positioning system (GPS).
However, if your deployment includes only one base station or one cell site, you can disable the use of an external GPS. Your base station will then use a time signal generated by a base station for time synchronization.
The GPS supplied time signal is known as an external time signal, which is the default setting of the base station when shipped from the factory.
The base station generated time signal is known as an internal time signal.
Configuring the GPS to supply the time signal
To use the GPS to supply the time signal to base stations:
1 Supply power to the entire system, as described in the section “Powering base stations” on
page 6-61 in this guide.
2 Connect the GPS to a base station, as described in the section “Connecting the GPS
equipment to a base station” on page 6-59 in this guide.
3 Connect all base stations in your cell to each other, in a daisy chain manner. For further
information, refer to the section “Connecting the GPS equipment to a base station” on page 6-59 in this guide.
4 Configure the base station to use an external time synchronization signal:
set airlink timing external
5-46 Configuring, Installing, and Using Carrier Infrastructure
5
Enable the set airlink afc parameter. This parameter allows a base station to automatically frequency lock to the external pulse from the GPS, which is one pulse per second.
set airlink afc enabled
6 Save changes in Flash memory by issuing the
7 For changes to take effect, reboot or reset the base station’s power. To reboot, type the
write
command.
following at the command prompt:
reboot
Configuring a base station to supply a time signal
There are two scenarios in which you might want to set up a base station to use internal time synchronization.
The first is a single base station at a site that is not part of a larger system with other sites. This base station may be set to use internal time synchronization.
The second scenario is a multiple base station site that is not part of a larger system with other sites. One of the base stations is set as a master base station. The master base station is set for internal time synchronization. It generates the 1-pulse-per-second (pps) for itself, and also outputs the 1 pps pulse for the other base stations. As such, you then set the other base stations to use external time synchronization.
To use a base-station generated time signal:
1 Connect all base stations in your cell to each other, in a daisy chain manner.
2 Supply power to the entire system, as described in the section,“Powering base stations” on
page 6-61 in this guide.
3 Configure the single base station or the master base stations to use an internal time
synchronization signal:
set airlink timing internal
4 Disable the set airlink afc parameter. You must disable this parameter, which otherwise
would allow a base station to automatically frequency lock to the external pulse from the GPS.
set airlink afc disabled
5 Store your changes in Flash memory by issuing the
6 For changes to take effect, reboot or reset the base station’s power. To reboot, type the
write
command.
following at the command prompt:
reboot
5-47
5-48 Configuring, Installing, and Using Carrier Infrastructure
C
HAPTER
6
I
TRANSCEIVER
Chapter overview
This chapter describes how to install the integral base transceiver station (I-BTS). The I-BTS enables you to install the base station and the antenna as one item, which could save tower rental costs. You can also install the base station and antenna separately, if desired.
C HAPTER
6
NSTALLING THE INTEGRAL BASE
STATION
(I-BTS)
This chapter describes:
• Components used to mount the base station on a building or tower
• Connecting the base station to the cell and to cell-site components
Before you begin
Before you install a base station on a roof top or tower:
• It is recommended that you assign a name to the base station. For more information refer to Chapter 2, “Configuring base stations‚” in this guide.
• It is also a good idea to configure the base station.
6-49
Cell wiring
Figure 6.1 shows how a cell, base stations, and ancillary equipment are wired together.
Figure 6.1 Cell wiring diagram
GPS unit
Panel antenna
GPS Interface cable
GPS inter-base station cable
Ethernet/power cable
TVS module
1 2 6
Load Termination
Coax jumper
Coax - main feed
Coax jumper
Base station
Optional serial connection and laptop computer
Ethernet cable
Backbone swtich Power supply
Backbone connection cable
UPS
AC power cord
6-50 Configuring, Installing, and Using Carrier Infrastructure
DC power cable
Installation overview
If you plan to install the antenna and the base station as a single unit:
1 Attach the right angle connector of antenna cable to antenna and apply weatherproofing
tape to the connector.
2 Attach the other end of the antenna cable to the base station and apply weatherproofing
tape to the connector.
3 Attach the antenna mounting brackets to the I-BTS. Use the antenna bracket integral base
kit (part number 123-0350-1002) to attach these brackets.
4 Attach the antenna to the mounting brackets.
5 Attach the straight end of the antenna cable to the BTS, attach the other end of the cable
(the right angle end of the cable) to antenna.
6 Set the antenna’s tilt.
7 Attach the pole mounting bracket to the back of the BTS.
8 Install the I-BTS to the tower, pole, or wall. Then, attach the GPS cables and Ethernet/
power cable to the I-BTS.
These steps are explained in greater detail in the sections that follow.
Antenna and bracket assembly for I-BTS
To attach the antenna mounting bracket to the I-BTS:
1 Attach the right angle connector of antenna cable to antenna. Apply weather proofing tape
to the connector.
2 Attach the straight end of the antenna cable to the filter on the base station. Apply weather
proofing tape to the connector.
Figure 6.2 Attaching antenna cable to I-BTS
3 Attach the L-shaped brackets (MP2) to the upper left and right of the I-BTS (see Figure
6.2). You must attach these brackets first, so that your wrench can access the screws holding the bracket to the I-BTS.
6-51
You can tighten the bolts to 10 FT LBS.
Figure 6.3 Attaching L-shaped brackets to I-BTS
4 Attach the antenna bracket (MP4) to the L-shape bracket (see Figure 6.3).
Figure 6.4 Attaching antenna bracket to the L-shape bracket
5 Attach the tilt guide bracket to the bracket on the antenna (see Figure 6.4):
a Align the holes on the side of the bracket with the holes on either side of the antenna’s
bracket.
6-52 Configuring, Installing, and Using Carrier Infrastructure
b Insert a bolt through each hole, and tighten a nut and washer on each bolt to hold the
tilt guide bracket to the antenna..
Figure 6.5 Attaching tilt guide bracket to the bracket on the antenna
6 Attach the tilt guide bracket (MP3) to the antenna bracket.Make sure the domed-side of
the washer faces the nut.
Figure 6.6
6-53
7 Attach the antenna brackets to the bolts on the left and right side of the antenna
(Figure 6.6)..You must attach these brackets to the antenna bolts before attaching the brackets to the base station.
Figure 6.7 Bracket on antenna bolt
8 Attach the antenna brackets to the bottom left and right sides of the I-BTS. Insert the
bolts through the hole in the bracket which provides the desired level of down tilt.
• Top set of holes (the holes closest to the antenna bolt) provide a ___ level of tilt.
• Middle set of holes provide a ___ level of tilt.
6-54 Configuring, Installing, and Using Carrier Infrastructure
• Bottom set of holes (the holes farthest from the antenna bolt) provide a ___ level of tilt.
Figure 6.8 Antenna brackets on bottom left and right sides of I-BTS
9 Adjust the antenna tilt and tighten hardware.
10Connect the cables on the bottom of the I-BTS.
6-55
Base station connectors
r
Figure 6.8 shows the connectors that the base station supports.
Figure 6.9 Base station connectors
Antenna connector
J4—Serial connector (green)
J3—GPS connector (black)
J2—GPS connector (black)
J1—Ethernet/power connecto
(orange)
6-56 Configuring, Installing, and Using Carrier Infrastructure
Ethernet (data) and power connector
On the base station, the Ethernet/power connector is orange.
The Ethernet and power connector supplies data and DC power to the base station. The connector to the TVS module has 8 pins:
• Ethernet transmit uses 2 pins.
• Ethernet receive uses 2 pins.
• Power V- uses 2 pins.
• Power V+ uses 2 pins.
Figure 6.9 shows the Ethernet and power connector which plugs into the TVS module.
Figure 6.10 Ethernet (data) and power connector
1
2
8
3
7
6
5
4
The connector to the base station has 13 pins.
Figure 6.11 Ethernet (data) and power connector
1
10
2
13
9
8
11
7
6
3
4
12
5
6-57
Ethernet/power connecting cable
Depending on your needs, you can order any of the following cables to connect the base station to the TVS module.
Table 6.1 Ethernet/power base station cable choices
Cable part number Length (feet)
597-6027-0002 2
597-6027-0004 4
597-6027-0006 6
597-6027-0010 10
597-6027-0025 25
597-6027-0050 50
597-6027-0100 100
597-6027-0200 200
597-6027-0300 300
Table 6.2 describes the pins of the Ethernet/power cable that connects the base station to the TVS device.
Table 6.2 Ethernet/power cable pins
Pin TVS connection Base connection
1 Tx+ -48 VDC
2 Tx- -48 VDC
3 Rx+ +48 VDC
4 Rx- +48 VDC
5+48 VDC Rx-
6+48 VDC Rx+
7 -48 VDC not used
8 -48 VDC not used
9Tx-
10 Tx+
11 not used
12 not used
13 not used
Table 6.3 describes the color and function of the wires in cable 597-6027-0xxx.
Table 6.3 Function of wires in cable 597-6027-0xxx
Wire color Wire function
White/orange Tx+ Ethernet
Orange Tx- Ethernet
White/green Rx+ Ethernet
Green Rx- Ethernet
Red +48 VDC
Red/white +48 VDC
Black -48 VDC
Black/white -48 VDC
6-58 Configuring, Installing, and Using Carrier Infrastructure
TVS module connectors
The TVS module has connectors on both its right and left sides.
Base station to TVS connector
The base station connector supplies power and an Ethernet connection to the base station. Connect cable 597-6027-0xxx to this side of the TVS module.
Figure 6.12 TVS module connector: Base station connector
BASE
CONNECTION
+ (RED)
+ (RED/WT)
+48 VDC ETHERNET
-(BLK/WT)
-(BLK)
POWER/ETHERNET
TX+(OG/WT)
RX-(GRN)
TX-(ORG)
RX+(GR/WT)
Note: Use the AUX +48 VDC and AUX ETHERNET connections only if you need to cut off the circular connector from the power/Ethernet cable (597-6013-0xxx). For example, you might not be able to use the circular connector if it cannot fit through a space or hole in a wall at the installation site. Instead, you may split the cable and put a 4 position .150" spaced terminal block on the Ethernet wires, and a 4 position .200" spaced terminal block on the power wires. Then, you will plug the appropriate connector from the split cable into the corresponding connector in the TVS module. Table 6.3, “Function of wires in cable 597­6027-0xxx” on page 6-57 describes the wires in the cable.
Power supply cable and ISP Ethernet network connector
The other side of the module has a connector for both an Ethernet cable coming from your ISP network and for the +48 VDC power coming from a power supply.
Note: To ensure your base station is properly protected from possible lightning strikes, ensure you plug the power cable coming from your power supply into this connector in the TVS module. If you plug the power cable into the base station connector side, the base station will power up, but you will not be properly protected against possible lightning strikes.
Figure 6.13 TVS module connector: power/Ethernet connector
ISP
ETHERNET
+48 VDC
POWER
5AMP
+-
6-59
Table 6.4 describes the recommended mating connectors. The use of these connectors are optional.
Table 6.4 Recommended mating connectors (optional)
Ref des Description
J1 2pin, 5.08mm Terminal Plug 1757019 277-1011-ND
J3 4pin, 5.08mm Terminal Plug 1757035 277-1013-ND
J4 4pin, 3.81mm Terminal Plug 1803594 277-1163-ND
Phoenix contact part number Digi-key part number
GPS connectors
On the base station, the GPS connectors are black.
The base station supports two GPS connectors: one connector is used to supply the GPS signal, either by a direct connection to the GPS device, or by a daisy chain connection to another base station in the cell. The other GPS connector is used to make a daisy-chain connection from the current base station to the next base station.
Figure 6.14 GPS connector
A
F
E
D
An RS-422 line feeds 1PPS+ and 1PPS- with the time synchronization pulse from the GPS equipment to the base station.
An RS-422 line also feeds 422Data+ and 422Data-, to allow data communication from the GPS device to the base station. This is one-way communication, with the GPS device giving the base station time information.
The 18V+ and ground pin supply power to the GPS device from the base station. The GPS device uses 18 volts DC at 150 milliamperes.
B
G
C
GPS connecting cable/Inter-base station connecting cables
You need one GPS device per cell. You then directly connect one base station within that cell to the GPS device. Next, the other base stations are connected to each other, using a daisy chain wiring scheme, so that all base stations in the cell can receive a GPS signal.
You can choose the length of the cable that connects the base station to the GPS receiver.
6-60 Configuring, Installing, and Using Carrier Infrastructure
• The cable that comes standard in the base station site installation kit is 100 ft. (part number 597-6025-0100).
• If desired, you can use a shorter cable to connect the base station to the GPS receiver. This alternate cable is 25 ft. (part number 597-6025-0025).
You can also choose the length of the daisy-chain cable that connects one base station to another base station.
• The standard cable shipped in the base station installation kit is 3 ft. (part number 597­6026-0003).
• If desired, you can use a longer cable to connect one base station to another. This cable is 10 ft. (part number 597-6026-0010)
• If you need to remove a base station for service, you can use the longer, 10 ft. cable to jumper the GPS cables together, and continue cell operation.
The last base station in the daisy chain requires a load termination to be connected to the GPS connection. This base terminator plug is 100 ohm (part number 515-6005-0001).
Serial interface connector
On the base station, the serial interface connector is green.
For base station configuration, the serial interface connector lets you directly connect the base station to a computer. The seven-pin connector is an RS-232 cable (10 ft.), physical interface.
Figure 6.15 Serial interface connector
Serial interface connecting cable
Cable 597-6028-0010 has a female, circular connector on one end, and a DB-9 female connector on the other end. Plug the DB-9 end of the cable into a computer. Plug the other end of the cable into the serial interface connector.
Antenna connector
A Ground
B Not used
C Not used
D Not used
E Tx data
F Rx data
G Not used
The antenna connector is a type N female connector. It has a built-in, internal 1/4 wave stub lightning protector. Connect the base station to the antenna using a coaxial cable. Connect the proper lightning ground wiring to the antenna lightning protector.
6-61
Mounting and grounding the base station
You can mount the base station to any surface. To mount the base station to a wall, you need to use the supplied mounting brackets. If you are installing the base station on a tower, you need to use mounting plates, which you need to acquire from another equipment supplier.
Mounting the base station to a wall
To mount the base station to a wall:
1 Find a surface suited to base station installation.
a Use installation kit 123-0100-0130 to install the base station to a wall or back board. The
kit supplies a bracket and hardware that are necessary to mount the base station.
b Plan to install the base station vertically, so the antenna connector is at the top (facing
skyward), and the other circular connectors are at the bottom (facing the ground).
c Make sure the area above and below the location where you want to install the base
station has a good distance for clearance. This clearance allows for proper air circulation and heat flow from the heat sink fins on the back of the base station. The clearance also allows for the coaxial cable and the other cable connections.
6-62 Configuring, Installing, and Using Carrier Infrastructure
2
Drill mounting holes into the surface, according to the dimensions shown in Figure 6.15.
Figure 6.16 Base station mounting template
10.375”
13.00"
3 To attach the base station to a wall, use the mounting brackets. Install them on the base
station first, then attach the brackets to the wall. To attach the brackets to the base station, use 5/16 inch x 18 inch UNC thread bolts and a lock washer which are supplied in the installation kit. Use the optional bolts to then attach the bracket to the surface.
6-63
Mounting the base station to a tower
To mount the base station on a tower:
1 Mount a back board or plate to the tower.
This back board or plate is custom hardware supplied by you, the service provider. Examples of material you may want to use for your back board or plate include a 1/4 inch aluminum plate, 3/4 inch green-treated plywood, or 2/12 inch green treated lumber.
2 After you have mounted your back board or plate to the tower, mount the base station to
the plate using installation kit 123-0100-0130.
Mounting the base station to a 19 inch rack
Base stations can be mounted to a 19 inch relay rack. Typically, NextNet Wireless stages this rack for customers as a service.
After staging, the base stations are mounted in the rack and wired to the TVS modules, the power supply, the backbone switch, and grounding plate.
If you desire to stage your own relay rack, you must use two 19 inch brackets (part number 350-0100-0101) and at least one grounding plate (part number 30-0100-0020).
Grounding the base station
The grounding location differs depending on the type of base station you are using.
• Base stations with the ability to change their modulation method (AMOD base stations) have a grounding connection on the hinged side of the base station.
• Base stations without the ability to change their modulation method have a grounding connection at the base of the antenna connection.
To ground either type of base station, run a 6-gauge or higher grounding wire from this connection to the ground bar on the rack, to the building’s ground connection on the roof, or to the grounding location at the tower.
The ground of the power can be either negative or positive. The 48 volt power input to the base station is floating, so either the positive or negative can be grounded.
6-64 Configuring, Installing, and Using Carrier Infrastructure
Connecting the antenna to the base station
This section provides tips you can use to connect the antenna to the base station for installations where the antenna is not mechanically mounted to the Integrated Base Station
It also provides step-by-step instructions for connecting the components to each other.
Antenna connection tips
Use the following tips when connecting the base station to the antenna:
• You connect the antenna to the base station using a coaxial cable. The size of the cable depends on the distance between the base station and the antenna.
• The greater the distance, the larger your coaxial cable needs to be, in order to maintain
low signal loss.
• It is recommended that you keep signal loss to a minimum. At a maximum, the signal
loss should be no more than 2 to 3 dB, including all coaxial cable and connectors.
• Use short coaxial jumpers from the base station to the main coaxial line, and from the main coaxial line to the antenna. It is recommended you use 1/2 inch flexible line, of the shortest length possible, while still allowing the flexibility to make a good connection.
• The base station contains an antenna connector with a 1/4 inch wave stub lightning protector. You do not need to place an external lightning protector in the coaxial cable.
Connecting the antenna to the base station
To attach the antenna to the base station:
1 Mount the antenna according to the manufacturer’s instructions.
2 Connect one end of a short coaxial jumper to the antenna. Connect the other jumper end
to the main coaxial cable.
3 On the base station’s antenna connector, connect one end of a short coaxial jumper.
Connect the other jumper end to the main coaxial cable coming from the antenna.
4 Make sure the coaxial line is properly grounded.
5 Properly seal the co-axial connections with weatherproof components, tape and wrap.
Connecting the GPS equipment to a base station
The GPS equipment provides a time synchronization signal to the base station. This signal is needed to ascertain the proper timing for time division duplexing (TDD).
The equipment is a smart antenna in a sealed, shielded, self-contained unit that houses a GPS receiver, GPS antenna, and interface circuitry.
When powered, the GPS provides accurate time, with a time pulse of one pulse per second, synchronized to Universal Time, Coordinated (UTC) within 150 nanoseconds.
GPS equipment mounting tips
You must use the NextNet Wireless supplied GPS system to supply a time synchronization signal to the base stations in a cell. You cannot use a GPS from another manufacturer.
6-65
The GPS does not ship with mounting accessories. You can obtain these accessories from many suppliers around the world, especially distributors of marine products.
Follow these tips when mounting the GPS:
• Mount the GPS unit on a threaded pipe or pole.
• The GPS mounting socket accepts a 1.0000 x 14 straight thread. It is recommended that the pole/pipe you use be 1.000 inch.
• Secure the pipe or pole to the building or other support structure.
• Ensure at least half of the sky is clearly visible to the unit.
• Expose the unit to the southern portion of the sky. GPS satellites move generally from the southwest to the northeast.
Connecting the GPS unit to the base station
One GPS unit can support numerous base stations in the same cell.
Use the GPS-to-base station cable to attach the GPS unit to one of the base stations in the cell.
To connect the cable to the GPS unit and to the base station (both of which have already been installed and mounted):
1 Connect the cable’s molded, circular female connector to the GPS unit.
2 After connecting the cable to the GPS unit, run the cable to the base station. Plug the
cable’s other end into the base station’s GPS connector.
3 Secure the cable that you just ran to an appropriate support structure. Coil and tie any
excess cable.
4 The GPS unit receives its power from the base station. The base station supplies power to
the GPS device, which uses 18 volts DC at 150 milliamperes.
5 So that the remaining base stations in the cell can receive a GPS signal, connect a base
station adjacent to the base station you just connected to the GPS unit.
Continue to use the daisy chain wiring scheme to connect the remaining base stations, until all of the base stations within the cell are connected to each other.
On the last base station in the daisy chain, connect the load termination on the open GPS connection.
Connecting to the backbone network
The base station connects to a TVS module. You then connect the TVS module to your network. Typically, base stations connect to a level 2 switch at the cell site, using a 10BaseT connection. The switch controls the base station data traffic to and from the backbone network.
Connect the switch to the backhaul network using the appropriate cabling.
6-66 Configuring, Installing, and Using Carrier Infrastructure
Powering base stations
This section describes tips for powering base stations, as well as the component connection sequence you need to use to properly power base stations.
Powering tips
• It is recommended that you use a redundant power supply for base stations.
• Each base station requires 48 volts DC at 3.0 amps maximum.
• The ground of the power can be either negative or positive. The 48 volt power input to the base station is floating, so either the positive or negative can be grounded.
• Power input is polarity sensitive, so be sure you connect V+ and V- properly.
• Depending on the type of equipment you own, supply power to the Ethernet switch and backbone network equipment.
• It is recommended that you use an uninterruptable power supply (UPS).
Tips for sizing the UPS include:
• Size the voltage and amperage of the power supply according to the number of base
stations at your cell site.
• Size the UPS according to the efficiency of the DC power supplies and power
requirements of the other ancillary equipment, such as the Ethernet switch and backbone network equipment.
• Consider the time you want to allow the system to operate on the UPS.
Powering the base station
The base station does not have a power switch. Rather, it receives its power when the UPS, power supply, and TVS module are connected to the base station through the Ethernet/ power cable.
To connect the base station to a power supply, connect these components in the order that follows:
1 Connect the base station to the antenna.
2 Connect the GPS to a base station, and use a daisy chain wiring scheme to connect the
other base stations.
3 Connect the base station to the TVS module using the Ethernet/power cable of the
desired length.
4 Use an Ethernet cable to connect the TVS module to the network. Use a standard DC
power cable to connect the TVS module to the power supply.
5 Connect the power supply to the UPS.
6 Connect the UPS to an AC power supply.
6-67
6-68 Configuring, Installing, and Using Carrier Infrastructure
C HAPTER
C
HAPTER
7
I
NSTALLING THE RACKMOUNT
7
BASE
Chapter overview
This chapter describes how to install the rackmount base station (RMB). It describes:
• Installing the cabinet onto a 19 inch rack
• Installing the power supply and switch
• Installing the RMB into the base station cabinet
• Connecting the RMBs to the cell and to cell-site components
Before you begin
Before you install RMBs:
• It is recommended that you assign a name to the RMB. For more information refer to Chapter 4, “Configuring base stations” in this guide.
• It is also a good idea to configure the base station with channel, VLAN, power, and other parameters, as described in Chapter 4, “Configuring base stations” in this guide.
STATION
(RMB)
7-67
Installation overview
This section provides an overview of the tasks you will perform when installing RMBs.
To install the RMBs:
1 Install the mounting brackets to the cabinet, then attach the cabinet to the rack.
Note: Do not operate the system before you have securely mounted the cabinet to a standard 19" rack that can handle the weight of the total system. To calculate the weight of your system, note that the housing weighs 43 pounds, each base station weighs 18 pounds, and each filter weighs 3.5 pounds.
So, if you have one cabinet, one RMB, and one filter, the weight of the total system is 64.5 pounds. Adjust this figure according to the number of RMBs and filters that you are using.
2 Attach the power supply and switch to the rack.
3 Insert the pre-configured RMBs into the cabinet.
4 Connect the cabinet to the following components:
•Switch
•Power supply
• Antennas or antenna filters, if filters are required.
•GPS
5 Follow your company’s good grounding practices. Typically, you will ground the cabinet
bus bar and the power supply.
6 Power on the base stations.
For further information about these tasks, refer to the sections in this chapter.
7-68 Configuring, Installing, and Using Carrier Infrastructure
Installing the mounting bracket and attaching cabinet to the 19-inch rack
Before inserting RMBs into the cabinet, attach the cabinet to the rack. To attach the cabinet to the rack:
1 Attach a mounting bracket to the left side and right side of the cabinet using the 16
supplied screws (8 per side).
Figure 7.1 Cabinet mounting bracket
Step 1: Attach to cabinet.
Step 2: Attach to rack.
2 Attach the cabinet to the rack with the 8 supplied screws, 4 for each side.
Note: Do not operate the system before you have securely mounted the cabinet to a standard 19" rack that can handle the weight of the total system. To calculate the weight of your system, note that the housing weighs 43 pounds, each base station weighs 18 pounds, and each filter weighs 3.5 pounds.
So, if you have one cabinet, one RMB, and one filter, the weight of the total system is 64.5 pounds. Adjust this figure according to the number of RMBs and filters that you are using.
7-69
Attaching the switch and power supply to the rack
Figure 7.2 shows where the switch and power supply should be installed on the rack, in relation to the cabinet and RMBs.
Figure 7.2 Location of switch and power supply in rack
RMBs
Switch
Power supply
Installing the RMBs into the cabinet
To install the RMB in the cabinet:
1 Grasp the RMB by handles on each side of the RMB.
2 Slide the RMB into the cabinet, aligning the guides along the side of the RMB with the
gliders inside the cabinet.
To ensure you align the RMB properly into the pre-installed harness connections, there is a guide pin on the back of the cabinet that fits into a guide pin opening on the back of the RMB. This guide pin will help the connectors on the back to align correctly.
3 When the RMB is properly installed and aligned in the cabinet, the plastic latches on the
side of the front plate snap into place.
Note: Always make sure the RMB is slid greater than halfway into the cabinet. An RMB that is not at least halfway installed in the cabinet could fall out of the cabinet.
7-70 Configuring, Installing, and Using Carrier Infrastructure
Connecting RMBs to cell (cell wiring)
There are minimal wiring tasks for you to perform, as the RMB simply slides into the pre­existing wiring when you place the RMB in the cabinet.
The cabinet into which the RMB is installed has a pre-wired harness. This harness supplies power and Ethernet connectivity to the RMB. After you connect the antenna to the appropriate connector, the RMB also receives airlink traffic. Finally, the harness supplies an alarm capability to the RMB, as well as a GPS signal.
Note: Make sure you have made all antenna connections before attempting to transmit. Do not attempt to transmit before the antennas are connected.
7-71
Figure 7.3 shows how a cell, 4 RMBs, and ancillary equipment are wired together.
Figure 7.3 Cell wiring diagram
To antennas
Cabinet mounted
base radios
Ethernet cables
Channel filters
(if required)
Power cables
Switch
Power supply
AC power
7-72 Configuring, Installing, and Using Carrier Infrastructure
Connecting power to the RMBs
This section describes how to supply power to RMBs in the cabinet, as well as recommendations for the type of power supply to use.
When choosing a power supply, keep in mind:
• Each base station requires 150 watts at 48 volts. So, if your cabinet holds 8 RMBs, the power supply should provide 1250 watts, at a minimum.
• The power supply you choose should use an “n + 1” configuration, so that the RMBs have a backup power source in case one of the power supply modules fails.
Powering the base station
To connect the base station to a power supply, connect these components in the order that follows:
1 Connect the RMB to the antenna.
2 If you are using a GPS to supply a timing pulse to the base stations, connect the GPS to
the GPS connector on the cabinet. Place a terminal plug on the other GPS connector on the cabinet.
Note: If you are using an RMB to supply the timing pulse to the other RMBs, set up the base station as described in the section “Configuring the time signal used by base stations.” The cable harness in the cabinet then supplies the other RMBs in the cabinet with timing information.
3 Connect the Ethernet cable to the switch.
4 Connect the RMB to the power supply.
5 Connect the power supply to the UPS, if a UPS is available.
6 Connect the power supply and the UPS to an AC power supply.
7-73
Figure 7.4 shows the location of the power connection on the bottom of the cabinet.
Figure 7.4 Power connections on bottom of cabinet
DO NOT DISCONNECT. Pre-wired power and NextNet Wireless preferred power supply
NextNet Wireless preferred power supply connector
50 Amp power connector (optional, for customer-provided power supply)
30 Amp battery backup connector
Table 7.1 describes the power connectors that you must use with the cabinet. If the exact connector is not available, use a connector that is similar to the one listed
Table 7.1 Connector type to use with cabinet connectors
Connector Connector type to use with
NextNet Wireless preferred power supply
Molex #39-01-2180
connector
50 Amp power connector (optional, for
Molex #42816-0212
customer-provided power supply)
30 Amp battery backup connector Phoenix #1848892
To connect power:
1 Perform one of the following:
• If you are using a power supply from or recommended by Nextnet Wireless, plug that
connector into the NextNet Wireless supplied power connector on the bottom of the cabinet.
• If you are using a different power supply, connect it to the 50-amp power connector,
found on the bottom of the cabinet.
2 If desired, connect a battery backup power supply to the battery backup connector.
7-74 Configuring, Installing, and Using Carrier Infrastructure
Powering tips
• It is recommended that you use a redundant power supply for base stations.
• Each base station requires 150 watts at 48 volts of power.
• The ground of the power can be either negative or positive. The 48 volt power input to the base station is floating, so either the positive or negative can be grounded.
• Power input is polarity sensitive, so be sure you connect V+ and V- properly.
• Depending on the type of equipment you own, supply power to the Ethernet switch and backbone network equipment.
• It is recommended that you use an uninterruptable power supply (UPS).
Tips for sizing the UPS include:
• Size the voltage and amperage of the power supply according to the number of base
stations at your cell site.
• Size the UPS according to the efficiency of the DC power supplies and power
requirements of the other ancillary equipment, such as the Ethernet switch and backbone network equipment.
• Consider the time you want to allow the system to operate on the UPS.
7-75
Grounding the RMBs
There is one grounding bar in each cabinet. Each bank of 4 RMBs are grounded to the bar.
The grounding bar also contains locations for grounding terminals so that you can ground the RMBs to your building’s ground bar.
Figure 7.5 Grounding the RMBs
Grounding lugs
7-76 Configuring, Installing, and Using Carrier Infrastructure
Turning on the RMB’s power
The front panel of the RMB has a programming cable connection, 5 light-emitting diodes, and a power button. Figure 7.6 shows the front panel of the RMB.
Figure 7.6 RMB LEDs
To turn on the RMB, press the power button. The LEDs then light. Table 7.2 describes what the base station LEDs indicate.
Table 7.2 Description of LEDs on the base station
LED Description
1 (PWR) When this green LED is lit, the RMB has power.
2 (NET) When this yellow LED is lit and blinking, information is being received on the
RMB’s Ethernet port.
3 (PPS) The LED indicates that the RMB is receiving the 1 pulse per second signal.
4 (AIR) When this LED is lit, the airlink on the RMB is operating.
5 (ALM) When this red LED is lit, an alarm on the RMB has been triggered.
POWERALMAIRPPSNETPWRDIAGNOSTICS
7-77
Base station connectors
This section describes the GPS connectors and the serial cable connectors. The serial cable is used to configure the base station with information that is unique to the carrier.
GPS connectors
Figure 7.7 shows the connectors that the base station supports.
Figure 7.7 Connector on the serial cable used in configuring base stations
An RS-422 line feeds 1PPS+ and 1PPS- with the time synchronization pulse from the GPS equipment to the base station.
An RS-422 line also feeds 422Data+ and 422Data-, to allow data communication from the GPS device to the base station. This is one-way communication, with the GPS device giving the base station time information.
The 18V+ and ground pin supply power to the GPS device from the base station. The GPS device uses 18 volts DC at 150 milliamperes.
GPS connecting cable/Inter-base station connecting cables
You need one GPS device per cell. You then directly connect one GPS connector on the cabinet to the GPS device. Then, on the remaining GPS connector on the cabinet, you connect the load termination.
7-78 Configuring, Installing, and Using Carrier Infrastructure
Power supply cable connections
Table 7.3 describes the pins of the power cable used with the RMB.
Table 7.3 Power cable pins
American wire
Pin number
Pin 1 18 AWG Black
Pin 2 18 AWG Black
Pin 3
Pin 4 18 AWG Black
Pin 5 18 AWG Black
Pin 6
Pin 7 18 AWG Black
Pin 8 18 AWG Black
Pin 9 22 AWG White
Pin 10 22 AWG Green
Pin 11 18 AWG Red
Pin 12 18 AWG Red
Pin 13
Pin 14 18 AWG Red
Pin 15 18 AWG Red
Pin 16
Pin 17 18 AWG Red
Pin 18 18 AWG Red
gauge (AWG) Color
Diagnostic cable connections
It is recommended that you use the diagnostic cable provided by NextNet Wireless to configure the RMBs. One end of the cable has a RJ-45 type connector.
Table 7.4 describes the cable’s pins.
Table 7.4 Diagnostic cable pin connections (RJ-45)
Pin number, color Connection
1 no connection
2 no connection
3 no connection
4, red GND
5, green RXD
6, yellow TXD
7 no connection
8 no connection
9 no connection
7-79
Loading...