Nokia 450 Circuit Diagram

After Sales Technical Documentation

THF–9 Series Transceivers
Service Accessories
Original 43/96
NMP Part No. 0275270
After Sales
Service Accessories
Technical Documentation

CONTENTS

Service Accessories – 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Audio Cable ADS–1 – 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Connector PCS–1 – 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PC/MBUS Adapter DAU–2 – 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SW Security Device ”Dongle” PKD–1 – 5. . . . . . . . . . . . . . . . . . . . . .
Dummy Battery Pack BTS–9F – 6. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Service Cable SCS–1 – 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Battery Adapter BDS–2 – 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Test Frame JBS–8 – 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Service Box JBS–7 – 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Modular Cable XCM–1 – 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Modular T–Adapter – 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
D9/D25 RS–232 Adapter – 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Modular Power Connector SCF–6 – 12. . . . . . . . . . . . . . . . . . . . . . . . .
Page – 2
Original 43/96
After Sales
Technical Documentation

Service Accessories

Audio Cable ADS–1
Product code: 0730011
Service Accessories
Audio cable is an adapter routing AF signals (MIC/EAR) from 8 pin modu­lar connector to two BNC connectors.
Original 43/96
Page – 3
After Sales
Service Accessories
Power Connector PCS–1
Product code: 0730012
Suitable adapter between JBS–7 and the power supply.
Technical Documentation
Page – 4
Original 43/96
After Sales
Technical Documentation
PC/MBUS Adapter DAU–2
Product code: 0750006
DAU–2 is connected between the phone and the serial (COM) port of the PC. It matches the M2BUS data bus signals to the serial data bus of the computer.
Service Accessories
SW Security Device ”Dongle” PKD–1
Product code: 0750018
SW security device ”Dongle” is a piece of hardware enabling the use of the PCLocals when connected to the parallel (LPT) port of the PC. Whit­out the dongle present it is not possible to use the service SW. Printer or any such device can be connected to the PC through the dongle if need­ed.
Caution: Make sure thet you have switched off the PC and the printer
before making connections!
Caution: Do not connected the PKD–1 to the serial port. You may
damage your PKD–1!
Original 43/96
Page – 5
After Sales
Service Accessories
Dummy Battery Pack BTS–9F
Product code: 0770035
Technical Documentation
G0770030
Dummy battery is convenient device when the battery reference voltage is to be programmed. JBS–7 has a voltage setting for supplying specified reference voltage needed for this programming. Of course the BTS–9F can be used to substitute the normal battery also during normal testing, and optionally the input d.c. may be taken from some external power sup­ply. However, one should take care not to exceed the voltage rating of the phone.
Page – 6
Original 43/96
After Sales
Technical Documentation
Service Cable SCS–1
Product code: 0770010
Service Accessories
Service cable SCS–1 is an adapter routing RF signal(s) from phone bot­tom connector to two BNC connectors. It also contains modular connector that can be used to service purpoces.
Original 43/96
Page – 7
After Sales
Service Accessories
Battery Adapter BDS–2
Product code: 0770013
Battery adapter is used when the condition of the battery pack is to be tested with either internal discharging feature, or with external capacity meter. It provides a suitable mechanical interface for charging and dis­charging.
Technical Documentation
Page – 8
Original 43/96
After Sales
Technical Documentation
Test Frame JBS–8
Product code: 0770014
Service Accessories
JBS–8 is used when the service work must be done without covers in the phone. The phone’s radio module is placed into plastic frame, which pro­vides the needed connections to the bottom– and battery connectors of the phone. RF connection is done by RF cable, which is as well included into the JBS–8.
Suitable d.c. power supply regulation for JBS–8 concept is provided by example JBS–7. Note, that the UI module (flex) is not required in this en­viroment. Note also, that some of the signal values give wrong results when RF shields are removed. Hence the phone should never be tuned without the shields.
Original 43/96
Page – 9
After Sales
Service Accessories
Service Box JBS–7
Product code: 0770015
Technical Documentation
Service box provides convenient test enviroment (regulated power supply, M2BUS, preset battery reference voltage, external RF connection, audio test loops, HOOK switch etc.) and mechanical interface in one box.
When AUDIO switch of JBS–7 is INT position, the AF signals are routed normally to the modular–type system connectors. When in EXT position, the AF signals are routed from the speaker pin of the bottom connector straght back to the external microphone pin of the phone. Thus the speech codec of the phone is able to feed the internally generated test signal to the loudspeaker line, and measure the same signal from the EXT MIC line. Whenever audio signals are to be monitored or measured outside the phone, the AUDIO switch of the JBS–7 must be in INT posi­tion.
HOOK switch of the JBS–7 enables the audio signals to be routed to and from the phone via the bottom connector also when the phone is in cellu­lar mode, for example during a test call to some cellular tester. When HOOK switch is in OFF position and the phone in cellular mode, the au­dios are always routed to earpiece and internal microphone.
Additionally JBS–7 has a spare battery slot, though which the battery may be connected to external capacity meter.
Note: When tuning the maximum power, do not use more than
10 volts d.c. in the power supply input of the JBS–7.
Page – 10
Original 43/96
After Sales
Technical Documentation
Modular Cable XCM–1
Product code: 4626131
XCM–1 is a standard 1 meter long flat cable with male modular–8 con­nectors in both ends. In a complete service concept three pieces of the XCM–1 is needed.
Service Accessories
Modular T–Adapter
Product code: 4626134
Modular T–adapter is suitable branching unit to provide the needed paral­lel modular connections.
Original 43/96
Page – 11
After Sales
Service Accessories
D9/D25 RS–232 Adapter
Product code: 4626170
Suitable adapter between DAU–2 and computers having 9 pin D connec­tor as a serial port.
Technical Documentation
Modular Power Connector SCF–6
Product code: 0770036
Page – 12
Original 43/96
After Sales
Technical Documentation
Service Accessories
[This page intentionally left blank]