FOUR WAY DMX DISTRIBUTOR USER MANUAL
Congratulations on purchasing your new DMX distributor. The unit has one input and four output.
absolutely electric isolation between input and output or between output and output. Two type of
DMX connector(3pin & 5pin)for each individual channel, each DMX output features a independent
driver. DATA+ & DATA- indicator. there is a DMX switch which is incorporated allowing to isolate
from the malfunction caused by DMX input on the case. we strongly recommend that you take
time to read this manual fully before you attempt to use the DMX distributor .
1. Technical specification
Power input ..............................................................................AC230V~ 50Hz(AC 120V~ 60Hz)
!!
Fuse(internal) ...........................................................................F500mA 250v. 5 x 20 mm(5pcs).
Dimension...........................................................................................................277 X172 X72MM
Weight...................................................................................................................................2.8KG.
2.Oprating instruction and connection
DMX IN
T
L
er
i
n
mon
k
o
u
t
a
l
DMX OUT
DMX input : from the DMX transmitting device
DMX output : connect to the DMX receiving device
2
1
1= Ground
2= Data -
1
2
3= Data+
3
3
1
5
1=
Ground
2= Data 3= Data+
1
5
4= Not used
2
4
5= Not used
3
2
4
3
Connection diagram:
1
!!
Caution:
Dmx conroller
Dmx conroller
Out
Dmx distributor
Receiver can not more than 32 units on one out channel
Use one terminator on the last receiver.
120
0 V
DMX OUT
+ +
--
0 0 0 0 0 0 0 0
00
1 2 3 4
--
+ +
00
+ +
Connector pin designaions shall be as follows:
pin 1: signal common (shield)
pin 2: dimmer drive complement (data 1-)
pin 3: dimmer drive true (data 1+)
pin 4: option second data link complement (data 2-)(not used)
pin 5: option second data link complement (data 2+)(not used)
Receiver
In
.....
Out1
In
.................
.................
Out2
In
Receiver Receiver
Receiver
.....
22
Dmx conroller
Out
Push on the push button. Nothing on link out put.
Receiver can not more than 31 units before Dmx distributor
Receiver can not more than 32 units on one out channel
Use one terminator on the last receiver.
--
+ +
00
In
Out
In
....
Receiver Receiver
--
00
Dmx distributor
Out
In
Out1
Out2
Receiver
Out
....
In
.................
.................
Out
....
In
Receiver
Receiver
In
In
Receiver
This apperatus must be earthed.
Do not apply power source before completely installation
Always disconnect from mains before replacing the fuse
To reduce risk of fire or electrical shock .do not expose to rain or moisture
Do not try to repair it when the circuit is out of order .Send it back to your
supplier for repairing
MADE IN CHINA