Attachment No.8
TEST VALUE AND TEST LIMIT (GST ONLY — NOT APPLICABLE TO CONSULT-II)
The following is the information specified in Mode 6 of SAE J1979.
The test value is a parameter used to determine whether a system/circuit diagnostic test is “OK” or “NG” while
being monitored by the ECM during self-diagnosis. The test limit is a reference value which is specified as the
maximum or minimum value and is compared with the test value being monitored.
Items for which these data (test value and test limit) are displayed are the same as SRT code items.
These data (test value and test limit) are specified by Test ID (TID) and Component ID (CID) and can be displayed on the GST screen.
SRT item Self-diagnostic test item DTC
(GST display)
TID CID
Test value
CATALYST
EVAP SYSTEM
HO2S
HO2S HTR
EGR SYSTEM EGR function
★
1:Except models A33 VQ30DE engine, CA33 VQ30DE engine 1999MY and A33 VQ30DE engine, CA33 VQ30DE engine 2000M
Three way catalyst function (Bank 1)
Three way catalyst function (Bank 2)
EVAP control system (Small leak)
EVAP control system purge flow monitoring P1447 06H 83H Min. X mV
EVAP control system (Very small leak) P1441
Heated oxygen sensor 1(Bank 1)
Heated oxygen sensor 1(Bank 2)
Heated oxygen sensor 2(Bank 1)
Heated oxygen sensor 2(Bank 2)
Heated oxygen sensor 1 heater(Bank 1)
Heated oxygen sensor 2 heater(Bank 2)
Heated oxygen sensor 2 heater(Bank 1)
Heated oxygen sensor 2 heater(Bank 2)
P0420 01H 01H Max. X P0420 02H 81H Min. X P0430 03H 02H Max. X P0430 04H 82H Min. X P0440 05H 03H Max. X P1440 05H 03H Max. X -
★
1 07H 03H Max. X P0133 09H 04H Max. X ms
P0131 0AH 84H Min. X mV
P0130 0BH 04H Max. X mV
P0132 0CH 04H Max. X mV
P0134 0DH 04H Max. X s
P0153 11H 05H Max. X ms
P0151 12H 85H Min. X mV
P0150 13H 05H Max. X mV
P0152 14H 05H Max. X mV
P0154 15H 05H Max. X s
P0139 19H 86H Min. X mV/500ms
P0137 1AH 86H Min. X mV
P0140 1BH 06H Max. X mV
P0138 1CH 06H Max. X mV
P0159 21H 87H Min. X mV/500ms
P0157 22H 87H Min. X mV
P0160 23H 07H Max. X mV
P0158 24H 07H Max. X mV
P0135 29H 08H Max. X mV
P0135 2AH 88H Min. X mV
P0155 2BH 09H Max. X mV
P0155 2CH 89H Min. X mV
P0141 2DH 0AH Max. X mV
P0141 2EH 8AH Min. X mV
P0161 2FH 0BH Max. X mV
P0161 30H 8BH Min. X mV
P0400 31H 8CH Min. X ℃
P0400 32H 8CH Min. X ℃
P0400 33H 8CH Min. X ℃
P0400 34H 8CH Min. X ℃
P1402 35H 0CH Max. X ℃
Te s t limit Application Unit
Applicable ・: Not applicable

Attachment No.9
TEST VALUE AND TEST LIMIT (GST ONLY — NOT APPLICABLE TO CONSULT-II)
The following is the information specified in Mode 6 of SAE J1979.
The test value is a parameter used to determine whether a system/circuit diagnostic test is “OK” or “NG” while
being monitored by the ECM during self-diagnosis. The test limit is a reference value which is specified as the
maximum or minimum value and is compared with the test value being monitored.
Items for which these data (test value and test limit) are displayed are the same as SRT code items.
These data (test value and test limit) are specified by Test ID (TID) and Component ID (CID) and can be displayed on the GST screen.
SRT item Self-diagnostic test item DTC
CATALYST Three way catalyst function (Bank 1)
EVAP SYSTEM
HO2S
HO2S HTR
EGR SYSTEM EGR function
EVAP control system (Small leak)
EVAP control system purge flow monitoring P1447 06H 83H Min. X mV
Heated oxygen sensor 1(Bank 1)
Heated oxygen sensor 1(Bank 2)
Heated oxygen sensor 2(Bank 1)
Heated oxygen sensor 1 heater(Bank 1)
Heated oxygen sensor 2 heater(Bank 2)
Heated oxygen sensor 2 heater(Bank 1)
Test value
(GST display)
Te s t limit Application Unit
TID CID
P0420 01H 01H Max. X P0420 02H 81H Min. X P0440 05H 03H Max. X P1440 05H 03H Max. X -
P0133 09H 04H Max. X ms
P0131 0AH 84H Min. X mV
P0130 0BH 04H Max. X mV
P0132 0CH 04H Max. X mV
P0134 0DH 04H Max. X s
P0153 11H 05H Max. X ms
P0151 12H 85H Min. X mV
P0150 13H 05H Max. X mV
P0152 14H 05H Max. X mV
P0154 15H 05H Max. X s
P0139 19H 86H Min. X mV/500ms
P0137 1AH 86H Min. X mV
P0140 1BH 06H Max. X mV
P0138 1CH 06H Max. X mV
P0135 29H 08H Max. X mV
P0135 2AH 88H Min. X mV
P0155 2BH 09H Max. X mV
P0155 2CH 89H Min. X mV
P0141 2DH 0AH Max. X mV
P0141 2EH 8AH Min. X mV
P0400 31H 8CH Min. X ℃
P0400 32H 8CH Min. X ℃
P0400 33H 8CH Min. X ℃
P0400 34H 8CH Min. X ℃
P1402 35H 0CH Max. X ℃
Applicable ・: Not applicable