キリする位置にカメラを固定する(接眼レンズや DS マウント
とカメラのレンズが接触しないように注意してください)。図
D はまだクッキリしていない状態の例です。
組み合わせにより図 C にならない場合もあります。
3. 図 E の状態の場合は、図 F のように接眼レンズに対して、カ
メラの右側が近い、あるいは、カメラが左にずれている状態で
す。カメラシュー固定つまみ⑥を緩め、カメラの液晶モニター
を見ながら、図 C の状態になるようにカメラの旋回方向と必
要であれば、カメラ左右調整つまみ③を操作してカメラの左右
を調整する。
・ Depending on the type of camera, its position, or zoom setting, vignetting may occur. Vignetting may
En
Fr
De
It
Se
Fi
No
Dk
not completely disappear. Carefully adjust the camera position so that vignetting is minimized.
・ When replacing batteries or recording media, the camera may or may not need to be removed from the
connected equipment depending on the camera. Either way, confirm alignment after replacing them.
・ Do not carry or transport the bracket while it is mounted on equipment. This may result in it falling.
・ There are many adjustable parts on this product. Before using it, thoroughly read about each of the
adjustment/fixing screws and functions to ensure correct use.
・ Because this product contains various movable metal parts, take care during use to avoid pinching
your fingers and advise children to take special care.
Shooting Precautions
・ Focus first using the focus ring on the Fieldscope/EZ-Micro you are using by viewing the camera's LCD
monitor, then make fine adjustments with the camera's AF (autofocus) function.
・ If you cannot focus on the subject using the camera's AF, lock the AF by pressing the shutter release
button halfway, then set the focus again using the focusing ring of the Fieldscope/EZ-Micro while
viewing the camera's LCD monitor.
・ With high-magnification shooting, the depth of field is shallow. Be sure to focus carefully.
・ When using the supplied cable release, slowly push to release the shutter. If you push too strongly, the
camera position may change.
・ With high-magnification shooting, you can prevent vibration by using a self-timer or remote switch.
・ If you notice external light on the LCD monitor or image (picture), use the supplied light shielding
rubber sheet to prevent light entering between the mount and lens of the camera. If lights still enter,
cover the whole equipment with a shield such as a black cloth.
・ Camera position may become misaligned during camera operation. Before releasing the shutter,
confirm the vignetting and adjust the camera if necessary.
・ Do not use flash when shooting.
12
Specifications
1. Compatible Digital Cameras: COOLPIX series
2. Combination possible with:
・EDG Fieldscope series + EDG Fieldscope eyepiece FEP series
・EDG Fieldscope series + EMA-1 + Fieldscope eyepieces
・Fieldscope + Fieldscope eyepieces
・EZ-Micro
Please refer to Nikon's website for the latest information about combinations of compatible
digital cameras.
3. Dimensions (when folded):
133 (W) x 131 (H) x 94 (D) mm (without screws)
• Specifications and design are subject to change without notice.
• No reproduction in any form of this manual, in whole or in part (except for brief
quotation in critical articles or reviews), may be made without written authorization
from NIKON VISION CO., LTD.
Jp
En
Fr
De
It
Se
Fi
No
Dk
13
Nomenclature & Functions
Jp
① Bracket fixing screw Screws tightly to fix the bracket to the eyepiece/DS mount
of EZ-Micro
En
② Body (Bracket) Attaches to the eyepiece/DS mount of EZ-Micro
Fr
(DS mount: mount for attaching a bracket to EZ-Micro)
De
③ Camera position adjustment knob Adjusts the camera position horizontally
It
(horizontal)
④ Camera position adjustment knob (vertical) Adjusts the camera position vertically
Se
⑤ Camera position fixing screw Fixes the camera position backward and forward
Fi
(backward and forward)
No
⑥ Camera shoe fixing screw Fixes the camera to prevent rotation
Dk
⑦ Camera support Supports the camera from underneath
⑧ Camera support fixing screwFixes the camera support ⑦
⑨ Cable release shaft fixing screw Fixes the rotating movement and height of the cable release
(rotating movement and height) shaft ⑪
⑩ Cable release socket Socket for cable release to be screwed into
⑪ Cable release shaft Adjusts the cable release socket ⑩ horizontally
⑫ Cable release shaft fixing screw Fixes the sliding cable release shaft ⑪
⑬ Light shielding rubber sheet attaching Attach light shielding rubber sheet to the bracket with 5
projections projections
⑭ Eyepiece mount (DS mount) Eyepiece/DS mount of EZ-Micro can be inserted
⑮ Camera attaching screw Attaches the camera to the camera shoe ⑰
⑯ Camera fixing screw Fixes the camera to the camera shoe ⑰
⑰ Camera shoe Facilitates camera attachment to the bracket ②
⑱ Camera shoe mount Socket for camera shoe ⑰ insertion
Before using the bracket, thoroughly read about the function of each of the above parts to ensure correct
usage.
14
!w
!q
!p
!e
1
9
!r
8
2
7
Jp
En
Fr
De
It
Se
Fi
No
Dk
6
!t
!y
!u
3
4
5
!i
15
Attaching
Jp
Attaching the bracket to the eyepiece/DS mount
En
1. Loosen the camera shoe fixing screw ⑥ , then take the camera
shoe ⑰ out of the camera shoe mount ⑱ . (Fig. 1)
Fr
De
It
Se
Fi
No
Dk
2. Loosen the bracket fixing screw ① .
Refer to the circled numbers on the "Nomenclature & Functions" page.
Attach the bracket to the eyepiece/DS mount.
Push all the way in, then fix it with the bracket fixing screw ① while
continuing to push. (Fig. 2)
Fig. 1
⑱
⑥
⑰
Fig. 2
[Note]
Please make sure that the bracket is securely fixed. If the camera is
not attached securely, it may fall because of its own weight.
3. Loosen the camera position fixing screw (backward and forward) ⑤ , then temporarily screw it down at the maximum
extended position. (Fig. 3)
16
①
⑤
Fig. 3
Attaching the camera to the bracket
1. Screw the camera attaching screw ⑮ into the camera's tripod holes
tightly to integrate the camera and the camera shoe ⑰ .
(Attach the supplied non-skid pad on the shutter release button.) (Fig.
4)
2. Insert the camera shoe ⑰ into the camera shoe mount ⑱ .
Tighten the camera shoe fixing screw ⑥ to stop the camera from
rotating temporarily. (Fig. 5)
[Note]
When you want to change the camera's position after fixing it with the
camera shoe fixing screw ⑥ , please do so after loosening the camera
shoe fixing screw ⑥ again.
Fig. 4
⑰
Fig. 5
⑥
Jp
En
Fr
De
It
Se
Fi
No
Dk
3. Turn on the camera.
Operate the zoom button (from wide to telephoto), and make sure the
camera's lens does not hit against the eyepiece/DS mount.
Then set the zoom at the wide setting. (Fig. 6)
Fig. 6
17
Attaching
Jp
Adjusting the optical axis
1. While viewing the camera's LCD monitor, adjust so that the circle of
En
the eyepiece aligns with the center of the LCD monitor by turning
Fr
the camera position adjustment knob (horizontal) ③ and camera
De
position adjustment knob (vertical) ④.
When turning on the camera, if what you see is like Fig. A, the field of
It
view of the Fieldscope/EZ-Micro is out of alignment to the lower left
Se
relative to the camera. Adjust the camera position adjustment knob
(horizontal) ③ and camera position adjustment knob (vertical) ④
Fi
until it looks like Fig. B.
No
2. Loosen the camera position fixing screw (backward and
Dk
forward) ⑤ , move the bracket and the camera forward and fix it
Refer to the circled numbers on the "Nomenclature & Functions" page.
where the field of view is clear and four corners of vignetting are
about the same size as in Fig. C.
(Make sure the lens does not hit against the eyepiece/DS mount.)
Fig. D is an example of the field of view not being clear enough.
Depending on your combination, it may not appear as in Fig. C.
3. If it appears like Fig. E, the right side of the camera is closer to the
eyepiece/DS mount or the camera is misaligned to the left as in Fig. F.
Loosen the camera shoe fixing screw ⑥ , then adjust the camera's
position to get it closer to Fig. C while watching the LCD monitor.
Operate the camera position adjustment knob (horizontal) ③ if
necessary.
4. Set at the zoom position where no vignetting occurs by operating
the camera's zoom (depending on the camera model, pay special
attention so that the lens does not hit against the eyepiece/
DS-mount). Vignetting may not completely disappear.
[Note]
If you see a black section as in Fig. E at the top or bottom of the field
of view, it cannot be adjusted to appear like Fig. C or Fig. D. Please
readjust the camera zoom position and use it where no vignetting
occurs.
18
③
⑤
④
Fig. AFig. B
Fig. CFig. D
Fig. E
⑥
Fig. F
Preparing for shooting
1. Loosen the camera support fixing screw ⑧ , then position the camera
support ⑦ to support the camera from underneath. (Be careful when
you lift up the camera, or the optical axis may become misaligned.) (Fig.
7)
2. Loosen the cable release shaft fixing screw (rotating movement and
height ) ⑨ and cable release shaft fixing screw ⑫ , then set the cable
release socket ⑩ position right above the camera's shutter release
button. (Fig. 8)
3. Make sure that the cable release socket ⑩ is set just a little above the
release button, but not touching it.
4. Attach the cable release. (Fig. 9)
5. When pushing the release button, make sure the top of the release
touches the non-skid pad attached to the shutter release button.
Attaching/how to use the light shielding rubber sheet
The supplied light shielding rubber sheet can be used to reduce the light
entering between the eyepiece/DS-mount and the lens of the camera.
1. Hook the holes of the light shielding rubber sheet onto the light shielding rubber sheet attaching projections ⑬ . (Fig. 10)
2. The excess sheet can be folded or cut depending on your camera's
dimensions, shape and how the light enters.
[Note]
If you readjust the camera position or operate the zoom after attaching
the light shielding sheet, please take care that the eyepiece/DS-mount
does not hit the lens of the camera.
Fig. 7
Fig. 8
Fig. 9
Jp
En
Fr
De
It
⑧⑦
⑩
⑩
⑫
⑨
Se
Fi
No
Dk
Fig. 10
⑬
19
Précautions d'emploi
Jp
・ En fonction du type d'appareil, de sa position ou de la configuration du zoom, un vignettage peut apparaître. Il se
En
peut que le vignettage ne disparaisse pas totalement. Réglez la position de l'appareil avec soin de façon à minimiser le
vignettage.
Fr
・ Lorsque vous changez les piles ou que vous enregistrez des supports, vous devrez peut-être, selon votre appareil,
De
retirer l'appareil de l'équipement auquel il est connecté. D'une façon comme d'une autre, veillez toujours à confirmer
l'alignement lorsque vous repositionnez l'appareil.
It
・ Ne portez pas et ne transportez pas le collimateur lorsque celui-ci est monté sur un équipement. Cela pourrait
Se
provoquer une chute.
・ De nombreuses pièces sont réglables sur cet appareil. Avant de l'utiliser, prenez le temps de bien lire chaque
Fi
fonctionnalité des vis de réglage / fixation afin de garantir une utilisation adéquate.
No
・ Du fait de la présence de nombreuses pièces métalliques détachables sur l'appareil, prenez garde en l'utilisant de ne pas
vous coincer les doigts et prévenez les enfants de faire très attention
Dk
Précautions lors des prises de vue
・Faites d'abord la mise au point à l'aide de la bague de mise au point sur le Fieldscope / Micro -EZ que vous utilisez.
Servez-vous de l'écran ACL, puis procédez aux réglages de précision avec la fonctionnalité AF (autofocus).
・ Si vous ne par venez pas à faire la mise au point sur le sujet avec la fonctionnalité AF de l'appareil photo, verrouillez la
fonctionnalité AF en appuyant à moitié sur le bouton de déclenchement de l'obturateur, puis faites à nouveau la mise
au point du Fieldscope / du Micro-EZ à l'aide de la bague de mise au point et de l'écran ACL de l'appareil photo.
・ Avec une prise de vue à fort grossissement, la profondeur de champ est superf icielle. Prenez soin de bien effectuer
votre mise au point.
・ Lorsque vous utilisez le câble déclencheur fourni, appuyez doucement pour déclencher l'obturateur. Si vous appuyez
trop fort, la position de la caméra pourrait changer.
・ Avec une prise de vue à fort grossissement, vous pouvez éviter les vibrations en utilisant un retardateur ou une
télécommande.
・ Si vous remarquez une lumière externe sur le moniteur ACL ou l'image (photo), utilisez l'écran de protec tion en
caoutchouc fourni pour empêcher la lumière de pénétrer entre la monture et l'objectif de l'appareil-photo. Si la
lumière pénètre toujours, recouvrez tout l'équipement d'une protection, comme un tissu noir.
・ Il se peut que la position de l'appareil photo soit mal alignée au cours du fonctionnement de l'appareil. Avant de
déclencher l'obturateur, confirmez le vignettage et réglez l'appareil, le cas échéant.
・ N'utilisez pas le f lash lors des prises de vue.
20
Caractéristiques
1. Appareils numériques compatibles : série COOLPIX
2. Association possible avec :
・La gamme Fieldscope EDG + Oculaires de la gamme Fieldscope EDG
・La gamme Fieldscope EDG + EMA-1 + Oculaires de la gamme Fieldscope EDG
・Fieldscope + Oculaires Fieldscope
・Micro-EZ
Pour en savoir plus sur les dernières informations concernant les associations avec des
appareils photos compatibles, consultez le site Internet de Nikon.
3. Dimensions (déplié) :
133 (l) x 131 (H) x 94 (p) mm (sans vis)
4. Poids :
300 g (sans les accessoires fournis)
5. Accessoires fournis :
câble déclencheur FSB x 1, pastille antidérapante x 2,
écran de protection à la lumière en caoutchouc x 1
• Les spécifications et la conception sont sujettes à modification sans préavis.
• Aucune reproduction totale ou partielle, sous quelle que forme que ce soit, (à
l'exception de brèves citations dans des magazines) ne peut être faite sans autorisation
écrite de NIKON VISION CO., LTD.
Jp
En
Fr
De
It
Se
Fi
No
Dk
21
Nomenclature/fonctions
Vis de fixation du collimateurPermet de visser fermement le collimateur aux oculaires ou à la monture
Jp
①
En
Corps (Collimateur)Se fixe à l'oculaire / la monture DS du Micro-EZ (monture DS : monture
②
Fr
Bouton de réglage de la position de l'appareil
③
De
photo (horizontal)
It
Bouton de réglage de la position de l'appareil
④
photo (vertical)
Se
Vis de fixation de la position de l'appareil
⑤
Fi
photo (en avant et en arrière)
No
Vis de fixation de la griffe de l'appareil photo Empêche la rotation de l'appareil photo
⑥
Support de l'appareil photoSoutient le dessous de l'appareil photo
Dk
⑦
Vis de fixation du support de l'appareil photo Vis de fixation du support de l'appareil photo ⑦
⑧
Vis de fixation de la tige du câble déclencheur
⑨
(mouvement de rotation et hauteur)
Emplacement du câble déclencheurEmplacement permettant de visser le câble déclencheur
⑩
Tige du câble déclencheurPermet de régler horizontalement l'emplacement du câble déclencheur ⑩
⑪
Vis de fixation de la tige du câble déclencheur Permet de maintenir en place la tige coulissante du câble déclencheur ⑪
⑫
Projections de fixation de l'écran de
⑬
protection à la lumière en caoutchouc
Monture de l'oculaire (monture DS)Il s'agit de l'endroit où un oculaire ou une monture DS pour Micro- EZ peut
⑭
Vis de fixation de l'appareil photoPermet de raccorder l'appareil photo à la griffe de l'appareil photo ⑰
⑮
Vis de fixation de l'appareil photoFixe l'appareil photo à la grif fe de l'appareil photo ⑰
⑯
Griffe de l'appareil photoFacilite la connexion de l'appareil photo au collimateur ②
⑰
Monture de la griffe de l'appareil photoEmplacement pour l'insertion de la grif fe de l'appareil photo ⑰
⑱
Avant d’utiliser le collimateur, veillez lire attentivement les fonctionnalités de chacune des pièces susmentionnées an de
garantir une utilisation adéquate.
22
DS pour le Micro-EZ
permet tant de fixer un collimateur au Micro -EZ)
Permet de régler horizontalement la position de l'appareil photo
Permet de régler verticalement la position de l'appareil photo
Permet de fixer la position de l'appareil photo en avant ou en arrière
Fixe le mouvement de rotation et la hauteur de la tige du câble
déclencheur ⑪
Permet de mettre un écran de protection en caoutchouc sur le collimateur
avec 5 projections
être inséré(e)
!w
!q
!p
!e
1
9
!r
8
2
7
Jp
En
Fr
De
It
Se
Fi
No
Dk
6
!t
!y
!u
3
4
5
!i
23
Loading...
+ 53 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.