Newcon Optik LRM1500SPD, LRM1200 User Manual

Operation Manual
LRM 1200 / LRM 1500
LRM 1500SPD
LASER RANGEFINDER MONOCULAR
105 Sparks Ave., Toronto, ON M2H 2S5, Canada
Read prior to activation
You have just purchased a sophisticated electro-optical device that emits invisible laser radiation. To operate it properly, please, read this manual carefully.
NEVER direct laser beam at the eyes of people or animals
NEVER aim the unit at the Sun or bright sources of light
NEVER
NEVER
NEVER
due to high voltage currents in the system
ALWAYS keep the unit out of the reach of children
ALWAYS
for a long period
ALWAYS
Caution - use of controls or adjustments, or performance of
procedures other than those specified herein may result in hazardous radiation exposure
Caution - use of optical instruments such as binoculars,
loupes, mirrors, lenses, etc. with this product increases eye hazard
Avoid eye exposure to direct laser beam or its close reflection
Prevent bright light from focussing through the eyepiece
subject the unit to impacts transport the unit without the case disassemble the unit. This may be hazardous for you
remove the battery when the device is not in use
store the unit in a dry place
TABLE OF CONTENTS
1. BRIEF DESCRIPTION............................................ 2
1.1 Principle of operation........................................... 2
1.2 Key Features ........................................................ 3
2. DEVICE APPEARANCE ........................................4
3. DELIVERY SET...................................................... 6
3.1 Standard delivery set............................................ 6
4. SPECIFICATIONS ..................................................7
5. OPERATION INSTRUCTIONS.............................. 9
5.1 Changing battery................................................ 10
5.2 Measuring procedure .........................................11
5.3 Maximum distance............................................. 11
5.4 Mode selection................................................... 12
5.5 Additional display information.......................... 14
6. STORAGE AND MAINTENANCE...................... 15
7. TROUBLESHOOTING ......................................... 16
8. WARRANTY......................................................... 17
9. CUSTOMER SUPPORT........................................ 18
10. QUALITY CERTIFICATE.................................... 19
1
CAREFULLY READ ALL THE INSTRUCTIONS
BEFORE USING THE UNIT!
FAILURE TO OBEY THE INSTRUCTIONS WILL
VOID THE WARRANTY AND MAY CAUSE
INJURY!
1. BRIEF DESCRIPTION
LRM 1200 / 1500 / 1500SPD Laser Rangefinder Monocular
(the unit) is an advanced laser range finder system that enables instant distance and speed (1500SPD modification only) measurement.
The unit complies with CFR 21, Part 1040.10.
An outstanding fully multi-coated optics coupled with an original circuitry design creates a system that outperforms any other product in its class and price range.
Principle of operation
The unit sends invisible, eye safe laser beam pulses to the target. The pulses reflected from the target are captured and processed by the digital circuitry. The time-of-flight delay between the sent and received pulses allows calculating the distance to the target.
2
Key Features
Distance is displayed in meters or yards Original digital circuitry allows ranging through most types
of glass, bushes and other obstacles
Three channel optical solution (optical, laser and receiver)
provides high accuracy
Two reticle shapes: Target quality display indicator (1200 / 1500 modifications
only) assures that results are reliable
On-board memory keeps results of last 10 measurements,
that can be recalled to the LCD
The unit automatically turns off when no button is pressed
for 10 seconds
-¦- or
3
2. DEVICE APPEARANCE
6
5
4
3
2
Fig. 1. Front view
1 - Eyepiece 2 - Objective lens 3 - Laser emitter lens 4 - Receiver lens 5 - M (Mode) button 6 - A (Action) button 7 - Body of the device 8 - Rubber grip
7
1
8
4
11
1
12
10
Fig.2. Rear view
1 - Eyepiece 9 - Battery compartment cover 10 - Tripod socket 11- Identification imprint 12 - Classification
imprint, shown below
9
5
3. DELIVERY SET
Standard delivery set
LRM 1200 / 1500 / 1500SPD is supplied in the following assembly:
Qty
LRM 1
9V Alkaline battery 1
Soft carrying case 1
Neck strap 1
Operation manual 1
Warranty card 1
6
4. SPECIFICATIONS
Optics
Magnification
Objective lens diameter
Exit pupil diameter
Field of view
Type of coating
Range Finder
Laser
Measuring range, LRM 1200
Measuring range, LRM 1500, 1500SPD
Accuracy
Meters/Yards display
Last 10 readings recall
Reticle
Target quality indicator
7x
25 mm
3.6 mm
8
Fully multi-coated optics
Class 1, eye safe, 905 nm
20 m – 1,200 m
20 m – 1,500 m
1.5 m
Yes
Yes
-¦- or
Yes
7
Speed Detector (LRM 1500SPD only)
Measured speed range 5-400 km/h
Accuracy ±2 km/h
Power
Battery 9V
'Low Battery' indicator Yes
Environmental
Operational temperature range
Storage temperature range
-25 / +50
-45 / +65
o
C (-13 / +122oF)
o
C (-49 / +149oF)
Mechanics
Tripod thread
Weight without battery
Dimensions
127 mm x 125 mm x 60 mm
¼” x 20
445 g
8
5. OPERATION INSTRUCTIONS
6
5
4
1 – Low battery indicator 3 – Units of measurement 4 – Measurement result
5 – Target quality indicator 6 – Laser active indicator 7 – Setup mode indicator 8 – Ready mode indicator
Fig. 3. Liquid Crystal Display as
seen through the eyepiece
2 – Reticle (either
8
7
1
2
3
-¦- or )
9
Changing battery
To install a battery:
Slide the battery compartment cover down (9, Fig. 2) Install the battery observing polarity Don’t apply superfluous strength while pushing the battery
inside the compartment.
Close the compartment cover
If the battery does not fit the compartment easily, it means that polarity was reversed
To take a battery out:
Slide the battery compartment cover down (9, Fig. 2) Shake the rangefinder gently towards the open end of the
battery compartment
Pull out the battery
The unit is fully operational when battery voltage is higher than 7V. A ‘LOW BATTERY’ warning is displayed when battery voltage falls below 7.2V.
Ni-MH rechargeable or other 9V batteries capable to sustain current drain up to 150 mA could be used to power the System.
10
Measuring procedure
To start the measuring procedure, remove the lens cover. Look through the eyepiece (1, Fig. 1, 2) and adjust the focus by its rotating.
When the Rangefinder is off the LCD is blank. To activate it press and hold A button (6, Fig. 1) for half a second. At start the unit comes into Ready to Measure mode indicated by the word ‘READY’ on the display visible through eyepiece. You may need to adjust the focus again so that both the display and distant objects are seen sharp through the optical system.
Pressing A button (6, Fig. 1) in Ready to Measure mode initiates measurement. The result of measurement is displayed in a form that depends on the measurement parameters (see Setup Mode).
If measurement is unsuccessful four dashes (‘----‘) will be displayed in the area (4, Fig. 3). For successful measurement the target must be at least 20 m away.
The unit will switch off automatically after 10 seconds of inactivity.
Maximum distance
Though maximum measurement distance depends on target reflectivity, weather conditions and other conditions, for most targets the unit will provide accurate ranging for up to 1200 (LRM 1200) or 1500 (LRM 1500 / 1500SPD) meters.
11
Target reflectivity depends on its color, surface finish, size, shape, position in relation to the laser beam, etc. Bright target colors are more reflective than darks. A polished surface is more reflective than a rough one. Larger targets reflect better than small ones. Ranging a target perpendicular to the laser beam provides better results than the one positioned under a sharp angle to the beam.
Weather conditions that influence air transparency (rain, fog, snow, mist) reduce maximum range. Bright sunny days will reduce performance as well, as IR sun radiation may interfere with reflected laser impulses.
While the unit will measure through many glass types, measuring through glass may reduce accuracy.
Natural hand tremor decreases the accuracy of long distance ranging. Using of a tripod is recommended to measure distant targets.
Mode selection
By pressing the Mode button (5, Fig.1), you can sequentially scan the Modes. The Mode under selection is indicated on the Display by flashing of the selectable feature. The "flashing" feature can be selected by pressing the Action button (6, Fig.1). The System operates in the setting Modes that are displayed as follows (refer to Fig.3):
Y/M: units of measurement: yards or meters (3, Fig.3).
12
KMH/MPH: units of speed measurement: km/hour or miles/hour (3, Fig.3) (LRM 1500SPD only).
Shape of the reticle: cross shape or rectangular shape (2, Fig.3).
rEC1: Data Recall mode. It returns results of the last 10
measurements on the display.
Measurement results are saved in on-board memory. When you enter the Data Recall mode, first measurement set number (display name:
Pressing M button moves the unit along the list of measurement set numbers and measurement results:
rEc 1) will start flashing.
rEc 1, rEc 2, …, rEc 0.
If distance was not measured, it will not appear in the list.
Measurement sets are numbered in reverse order: first recalled set is the result of the last measurement.
Pressing A button at any moment within the list of recalled results (or pressing M button at the end of the list) brings the unit to Ready to Measure mode.
Clr: clear data function: upon pressing the Action button (6) (fig.1) the entire data from all previous measurements will be erased.
13
Additional display information
Distance measuring procedure includes instant statistical processing of the package of single measuring sessions. If there is more than one measured target in the field of view, the embedded software estimates the most probable one by calculating the number of reflected pulses multiplied by the target statistical weight. This mechanism allows automatic mitigation of the influence of obstacles like rain, flakes, trees, wires and so on.
Qualitative result of the statistical processing is presented on the Display as a message TARGET REFLECTION (5, Fig 3). There are three statistical qualifications of the reflected signal:
Reliability of ranging depends on the number of impulses that reflect from the target and reach the unit. The unit informs the user:
TARGET REFLECTION LOWranging results have low
statistical reliability,
TARGET REFLECTION MED
medium statistical reliability,
TARGET REFLECTION HIGH
high statistical reliability.
The target reflection feature is not available in 1500SPD model.
– ranging results have
– ranging results have
14
6. STORAGE AND MAINTENANCE
The unit is a sophisticated precision optical instrument equipped with laser and electronics. Therefore, it should be handled with due care.
Keep away from direct sunlight.
Avoid impacts, jolts, dust, moisture, and sharp changes of
temperature.
o
Do not use the device at temperatures higher than 50
(122
o
F).
Prevent unit from direct sunlight
Do not touch optical surfaces. Doing so may damage the
anti-reflection coating.
Clean optical surfaces only with professional camera lens
cleaning supplies.
Clean the exterior of the unit with a soft clean cloth.
Keep away from heating appliances and central heating.
Remove the battery when storing the device for long time.
All repair works must be performed only by an authorized
service.
Prevent bright light from focussing through the eyepiece
C
15
7. TROUBLESHOOTING
The ranging does not work. The display is transparent.
Check the charge of the battery. Replace it if it is weak.
Black dots are visible on LCD.
Liquid Crystal Display may have small black dots, scratches and other blemishes inherited from the manufacturing process. These flaws are strictly regulated by number, area and location and do not degrade the product's measurement capabilities.
Range measurement cannot be obtained.
Make sure that neither your hand nor finger is blocking
objective lens, laser emitting lens or receiver lens.
Hold the unit firmly (avoid hand tremor) while pressing the
Action button.
Check that the target is within measuring range of the device.
16
8. WARRANTY
NEWCON warrants this product against defects in material and workmanship for one year from the date of the original purchase. Longer warranty is available, subject to the terms of the specific sales contract. Should your Newcon product prove to be defective during this period, please deliver the product securely packaged in its original container or an equivalent, along with the proof of the original purchase date to your Newcon Dealer.
Newcon will repair (or at its option replace comparable model), the product or part thereof, which, on inspection by Newcon, is found to be defective in materials or workmanship.
What This Warranty Does Not Cover:
NEWCON is not responsible for warranty service should the product fail as a result of improper maintenance, misuse, abuse, improper installation, neglect, damage caused by disasters such as fire, flooding, lightning, improper power supply, or service other than by a NEWCON Authorized Service.
Postage, insurance, and shipping costs incurred while presenting your NEWCON product for warranty service are your responsibility. If shipping from North America please include a cheque or money order payable to NEWCON OPTIK for the amount of US$15.00 to cover handling and return shipping.
with the same or
17
9. CUSTOMER SUPPORT
Should you experience any difficulties with your NEWCON OPTIK product, consult this manual first. If the problem remains unresolved, contact our customer support department at (416) 663-6963 or toll free at 1-877-368-6666. Our operating hours are 9am-5pm, Monday - Friday, Eastern Standard Time. At no time should equipment be sent back to Newcon without following the instructions of our technical support department.
NEWCON OPTIK accepts no responsibility for unauthorized returns.
To locate NEWCON Authorized Dealer call:
Tel: +1(416) 663-6963 Fax: +1(416) 663-9065
Email: newconsales@newcon-optik.com
Web: www.newcon-optik.com
The defective products should be shipped to:
US customers:
2498 Superior Ave. Cleveland, OH 44114
all other countries:
105 Sparks Ave., Toronto, ON, M2H 2S5, CANADA
18
10. QUALITY CERTIFICATE
LRM 1200 LRM 1500SPD
LRM 1500
The unit indicated above has passed the quality inspection.
Production date
Serial number
Quality Inspector
Purchase date
19
NEWCON OPTIK Printed in Canada
Loading...