Nelson Heat Trace VH1, VH2 Application Information

NELSON

SILICONE TANK HEATING PANEL INFORMATION

VH1
VH2
Fiberglass-Reinforced Silicone Rubber Insulation Jacket
Stranded Steel Sheath
Conduit Entry (1/2” NPT)
Description:
SPECIFICATION/APPLICATION
Nelson Type VH Silicone Tank Heating Panels are constructed with high temperature resistance elements vulcanized between two thin layers of
Principle of Operation:
The use of surface heating panels on metallic tanks and vessels provides larger amounts of heat in smaller areas than when heating cables are used. The labor
Application:
Nelson's VH Heating Panels are suitable for installation on metallic tanks and vessels for freeze protection or process temperature maintenance up to 175°F. Any number of heating panels can be installed on a single tank and connected in parallel or series to minimize electrical distribution
fiberglass-reinforced silicone rubber and a stainless steel sheath which provides additional mechanical protection and a ground path for hazardous area
to install heating panels is less than a comparable heating cable installation. The heating panels' high concentration of heat allows for significant heat-up capacity to
requirements. For applications in which the fluid may drop below the level of the heating panel, a dual thermostat arrangement is recommended. One sensor is installed on the tank to provide temperature control while the second sensor is installed on the surface of the highest mounted heating panel acting as
installations. The unique panel construction provides a rugged, water and chemical resistant sheath with good flexibility down to -70° F.
be installed on the tank surface or for the heat to be focused on a smaller area when low fluid levels in the vessel require heat.
a hi-temperature cutout switch to protect the heater from abnormal conditions. The panels are easily attached with suitable banding materials and must be mounted below the minimum fluid level on the vessel surface.
NELSON
SILICONE TANK HEATING PANEL INFORMATION
Performance and Rating Data:
Tank
Heater
VH1-500 12 X 22 500 120 4.17
VH1-1000 18 X 28 1000 120 8.33
VH2-500 12 X 22 500 240 2.08 VH2-1000 18 X 28 1000 240 4.17 VH2-2000 24 X 42 2000 240 8.33
Heater Specifications:
Maximum operating temperature: 500°F
Maximum temperature (UL recognition): 428°F
Minimum ambient temperature: -70°F
Thickness: .060"
Lead length: 24"
Weight: 12 oz/ft2
Approvals: FM Ordinary Locations
Hazardous (Classified) Locations
Class 1; Division 2; Groups A, B, C & D
Class 1; Zone 2
Nelson Heat Tracing Systems products are supplied with a limited warranty. Complete Terms and Conditions may be found on Nelson's website at
www.nelsonheaters.com.
SPECIFICATION/APPLICATION
Size
Inches
FOR 208 VOLTS MULTIPLY VH2 WATTAGE BY 0.75
Watts
@100°F
Voltage
Vac
Load
Amps
P.O. BOX 726 TULSA, OKLAHOMA 74101 • 918-627-5530 • 918-641-7336 • www.nelsonheaters.com 313-SA-001 © 2007 Nelson Heat Tracing Systems March 2007