Lumen iL33 ASSY T325R RF IR PR
1x | ASSY T325R RF
2x | lter 2x | connector RJ454x | insullation ring
Warning
This equipment should be installed, operated, serviced, and repaired by qualied personnel only. The installation and interconnection of this equipment to facility wiring and other
equipment must be done by a competent, qualied craftsperson who is familiar with applicable standards and codes governing the installation. Installation methods, practices, or
procedures that are unauthorised or done improperly are dangerous and could result in serious personal injury or damage to property and equipment.
20mm
dimensions
5'0.41"
325mm
1'0.80"
0.79in
2.36in
60mm
277,5mm
Mounting holes
Use M10-studs
10.93in
conduit or slit
(topview)
1534.3mm
322mm
328.6mm
1'0.68"
1'0.94"
(Customer counter)
4'6.26"
9.12in
1378.3mm
231.7mm
97.7mm
3.85in
N.V. Nederlandsche Apparatenfabriek “Nedap”
Parallelweg 2, NL-7141 DC Groenlo (The Netherlands)
Quick reference : ASSY T325R RF IR PR
Copyright © by N.V. Nederlandsche Apparatenfabriek NEDAP. No part of this drawing may be reproduced or distributed
in any form or by any means, or stored in a data base or retrieval system without the prior written permission of NEDAP.
Mail: support-retail@nedap.com
1
dsgn
date
item
: CvdB
: 28 March 2018 1:31 PM
: 9224386
document
revision
: T9224386-45.01
: A.01

90mm / 3.5”
ø 13mm / ø 0.5”
drill the hole
Ø 13 mm (Ø 0.5in)
1
90 mm (3.5in)
1 Drill the hole
2 Clean the hole
3 Insert Hilti-hit
4 Place the nut
always use a nylon insulation ring
2
3
4
1
2
2
3
1 Nut M10 (not included in installation set)
2 Retainer ring M10 (not included in installation set)
3 Nylon insulation ring M10 (included in installation set)
remove covers
1
1
1 Screw M3x10
2

installation orientation
The arrow indicates the
direction to the store exit.
place near to a wallsocket (RF)
Power Inserter (P.I.)
always on the right side.
distance to the wall (RF)
distance to a normal door or sliding door (RF)
> 20 cm (7.9in)
> 20 cm (7.9 in.)
> 40 cm (15.8in)
> 40 cm (15.8 in.)
3