NEC Express5800, R120h-2M, N8100-2562F, N8100-2563F, N8100-2564F System Configuration Manual

...
NEC Express5800/R120h-2M
System Configuration Guide
Introduction
This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and
proper configuration of your NEC Express5800 server.
January 25, 2018 Revision 5.0
NEC Corporation
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 2
Contents
MODEL LINEUP ............................................................................................................. 4
8x2.5-inch Drive Model ........................................................................................................... 4
8x3.5-inch Drive Model ........................................................................................................... 4
24x2.5-inch Drive Model ......................................................................................................... 4
12x 3.5-inch Drive Model ........................................................................................................ 4
TECHNICAL SPECIFICATION ....................................................................................... 5
Specification ................................................................................................................................. 5
CONFIGURATION DIAGRAM ........................................................................................ 7
Expansion slot Map ...................................................................................................................... 9
SERVER CONFIGURATION ......................................................................................... 10
1 Base Models .......................................................................................................................... 10
2 Processors ............................................................................................................................ 10
3 Memory .................................................................................................................................. 13
3.1 Memory Configuration Feature Comparison ................................................................ 13
3.2 Memory ......................................................................................................................... 13
4 Internal Storage .................................................................................................................... 14
Drive Bay Configuration ............................................................................................... 14
Drive Bay for 8x 2.5-inch Drive Model .................................................................................. 15
Storage Controllers and Options .................................................................................. 19
List of the configuration for Internal Drive and RAID ............................................................ 19
Internal Drives .............................................................................................................. 21
5 Optical Drive ......................................................................................................................... 23
6 Flash FDD .............................................................................................................................. 24
7 PCI Riser Card /PCI Card ..................................................................................................... 25
PCI Riser Card ............................................................................................................. 26
Network Interface Controller ........................................................................................ 27
External Storage Controller .......................................................................................... 29
Serial Port Adapter ....................................................................................................... 31
ExpEther Board ............................................................................................................ 31
8 Other Add-in Components .................................................................................................. 32
Power Supply ............................................................................................................... 32
High Performance CPU Heatsink ................................................................................. 34
Fan Kit .......................................................................................................................... 35
Front Panel Kit .............................................................................................................. 35
9 Product Name / Description ................................................................................................ 35
Trusted Platform Module Kit ......................................................................................... 35
USB Memory Kit ........................................................................................................... 35
Power Cable for GPU ................................................................................................... 36
10 Factory Server Setting Service ......................................................................................... 37
Memory RAS Settings ................................................................................................ 37
11 Add-on Components .......................................................................................................... 37
17-inch LCD Console Drawer ..................................................................................... 37
KVM Switch ................................................................................................................ 38
Server Management License ..................................................................................... 38
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 3
Dust Proof Filter Kit .................................................................................................... 38
Slide Rail Kit ............................................................................................................... 39
Cable Management Arm ............................................................................................. 39
Starter Pack DVD ....................................................................................................... 39
REFERENCES .............................................................................................................. 40
External Views ............................................................................................................................ 40
Front and Rear Views ........................................................................................................... 40
Dimensions (mm) ....................................................................................................................... 42
General Supplementary Matters ............................................................................................... 43
Memory Supplementary matters .............................................................................................. 43
Internal drive supplementary matters ...................................................................................... 45
Server Management ................................................................................................................... 47
OS Support Matrix for PCI Cards and Embedded Controllers .............................................. 48
Supported PCI Cards and Installable Slots ............................................................................. 49
Expansion Slots .................................................................................................................... 50
Supported Tape and Removal Disk Backup Drive List .......................................................... 50
Copyright Notice and Liability Disclaimer ............................................................................... 51
REVISION HISTORY ..................................................................................................... 52
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 4
Model Lineup
8x2.5-inch Drive Model
8x3.5-inch Drive Model
24x2.5-inch Drive Model
12x 3.5-inch Drive Model
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 5
Technical Specification
Specification
Model
R120h-2M
8x 2.5-inch Drive Model
24x 2.5-inch Drive Model
8x 3.5-inch Drive Model
12x 3.5-inch Drive Model
Part Number
N8100-2562F
N8100-2563F
N8100-2564F
N8100-2565F
Processor
Type
Intel® Xeon® Processor Bronze 3104(6C/6T, 1.70 GHz, 8.25MB, TDP 85W) Bronze 3106(8C/8T, 1.70 GHz, 11MB, TDP 85W) Silver 4108(8C/16T, 1.80 GHz, 11MB, TDP 85W) Silver 4110(8C/16T, 2.10 GHz, 11MB, TDP 85W) Silver 4112(4C/8T, 2.60 GHz, 8.25MB, TDP 85W) Silver 4114(10C/20T, 2.20 GHz, 13.75MB, TDP 85W) Silver 4116(12C/24T, 2.10 GHz, 16.50MB, TDP 85W) Gold 5115(10C/20T, 2.40 GHz, 13.75MB, TDP 85W) Gold 5118(12C/24T, 2.30 GHz, 16.50MB, TDP 105W) Gold 5120(14C/28T, 2.20 GHz, 19.25MB, TDP 105W) Gold 5122(4C/8T, 3.60 GHz, 16.50MB, TDP 105W) Gold 6126(12C/24T, 2.60 GHz, 19.25MB, TDP 125W) Gold 6128(6C/12T, 3.40 GHz, 19.25MB, TDP 115W) Gold 6130(16C/32T, 2.10 GHz, 22MB, TDP 125W) Gold 6132(14C/28T, 2.60 GHz, 19.25MB, TDP 140W) Gold 6134(8C/16T, 3.20 GHz, 24.75MB, TDP 130W) Gold 6136(12C/24T, 3 GHz, 24.75MB, TDP 150W) Gold 6138(20C/40T, 2GHz, 27.50MB, TDP 125W) Gold 6140(18C/36T, 2.30 GHz, 24.75MB, TDP 140W) Gold 6142(16C/32T, 2.60 GHz, 22MB, TDP 150W) Gold 6144 (3.50 GHz, 8C/16T, 24.75MB, TDP 150W) Gold 6146 (3.20 GHz, 12C/24T, 24.75MB, TDP 165W) Gold 6148(20C/40T, 2.40 GHz, 27.50MB, TDP 150W) Gold 6150(18C/36T, 2.70 GHz, 24.75MB, TDP 165W) Gold 6152(22C/44T, 2.10 GHz, 30.25MB, TDP 140W) Gold 6154(18C/36T, 3GHz, 24.75MB, TDP 200W) Platinum 8153(16C/32T, 2 GHz, 22MB, TDP 125W) Platinum 8156(4C/8T, 3.60 GHz, 16.50MB, TDP 105W) Platinum 8158(12C/24T, 3GHz, 24.75MB, TDP 150W) Platinum 8160(24C/48T,2.10 GHz, 33MB, TDP 150W) Platinum 8164(26C/52T, 2GHz, 35.75MB, TDP 150W) Platinum 8168(24C/48T, 2.70 GHz, 33MB, TDP 205W) Platinum 8170(26C/52T, 2.10 GHz, 35.75MB, TDP 165W) Platinum 8176(28C/56T, 2.10 GHz, 38.50MB, TDP 165W) Platinum 8180(28C/56T, 2.50 GHz, 38.50MB, TDP 205W) Gold 6134M(8C/16T, 3.20GHz, 24.75MB, TDP 130W) Gold 6140M(18C/36T, 2.30 GHz, 24.75MB, TDP 140W) Gold 6142M(16C/32T, 2.60 GHz, 22MB, TDP 150W) Platinum 8160M(24C/48T, 2.10 GHz, 33MB, TDP 150W) Platinum 8170M(26C/52T, 2.10 GHz, 35.75MB, TDP 165W) Platinum 8176M(28C/56T, 2.10 GHz, 38.50MB, TDP 165W) Platinum 8180M(28C/56T, 2.50 GHz, 38.50MB, TDP 205W)
Number of Processors
1 or 2
Chipset
Intel® C621 Chipset
Memory
Type
DDR4-2666 Registered DIMM (8/16/32GB) DDR4-2666 Load Reduced DIMM (64/128GB)
Standard Capacity
0 GB
Maximum Capacity
3 TB (24 x 128 GB)
Memory protection
ECC, x4 SDDC, x4 DDDC, Memory Mirroring, Memory Sparing
Internal Storage
Standard Capacity
0 GB
Disk Controller
SATA : 6Gb/s, RAID 0/1/5/6/10/50/60 (Optional) SAS: 12 Gb/s, RAID 0/1/5/6/10/50/60 (Optional)
Hot Plug
Supported
Optical Disk Drive
Optional
-
Optional
-
Optical Drive Bays
1 - 1
-
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 6
Model
R120h-2M
8x 2.5-inch Drive Model
24x 2.5-inch Drive Model
8x 3.5-inch Drive Model
12x 3.5-inch Drive Model
Standard Disk Drive Bays
8
24
8
12
Expansion Slots
Standard
Total: 5 slots available 1 PCIe 3.0 x16 (x16 connector) 2 PCIe 3.0 x8 (x8 connector) 1 PCIe 3.0 x8 (x8 connector) for a dedicated RAID card 1 PCIe 3.0 x8 (x8 connector) for a dedicated LOM controller * The slot mix changes by installing an optional riser card.
Video
Controller (VRAM)
Integrated in Server Management Controller (16MB)
Resolution
640x480, 800x600, 1,024x768, 1,280x1,024, 1,600x1,200, 1,920x1,200
Interfaces
Front
1x USB3.0 1x USB2.0 (BMC)
1x USB3.0 1x USB2.0 (BMC) 1x DisplayPort
-
Rear
2x USB3.0, 1x VGA (15-pin mini D-sub), 1x Management LAN connector (RJ-45), 4x Data LAN connector (RJ-45), 1x Serial (9-pin mini D-sub, Optional)
Internal
2x USB3.0, 2x SATA 2.0
Redundant Fan
Standard, hot plug
Redundant Power Supply
Optional, hot plug
Power Supply
1-2 x 500 Watt, 800 Watt, 1600 Watt 80 PLUS® Platinum certified hot plug PSU 500Watt, 800 Watt : 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz 800Watt, 1600 Watt : 200-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Dimensions (W x D x H )
445.5 x 679.4 x 87.3 mm
17.5 x 26.7 x 3.4 in (2U)
445.5 x 730.2 x 87.3 mm
17.5 x 28.7 x 3.4 in (2U)
Temperature, Relative Humidity (non-condensing)
Operating: 10° to 35° C / 50° to 95° F, 8 to 90% Non-Operating: -30° to 60° C / -22° to 140° F, 5 to 95%
Regulatory and Safety
FCC, UL/cUL, CB, CE, Mexico (CoC), RCM, RoHS, WEEE
Operating Systems
Microsoft® Windows Server® 2012 R2 Standard Microsoft® Windows Server® 2012 R2 Datacenter Microsoft® Windows Server® 2016 Standard Microsoft® Windows Server® 2016 Datacenter Red Hat Enterprise Linux 7.3 or later VMware ESXi 6.0 Update 3 VMware ESXi 6.5 Update 1
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 7
Configuration Diagram
8x 2.5-inch Drive Model
Legend: Standard Components Mandatory Components
24x 2.5-inch Drive Model
Legend: Standard Components Mandatory Components
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 8
8x 3.5-inch Drive Model
Legend: Standard Components Mandatory Components
12x 3.5-inch Drive Model
Legend: Standard Components Mandatory Components
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 9
Expansion slot Map
Legend
Remarks
Standard Riser
LOM
PCIe 3.0 x8, x8 connector, for a dedicated LOM controller
RAID
PCIe 3.0 x8, x8 connector, for a dedicated internal RAID card
Slot 1
PCIe 3.0 x8, x8 connector, Full-height, Half-length
Slot 2
PCIe 3.0 x16, x16 connector, Full-height, Half-length
Slot 3
PCIe 3.0 x8, x8 connector, Full-height, Half-length
(Option) Add N8116-62 2nd Riser Card
Slot 4
PCIe 3.0 x8, x8 connector, Full-height, Full-length
2CPU required
Slot 5
PCIe 3.0 x16, x16 connector, Full-height, Full-length
2CPU required
Slot 6
PCIe 3.0 x8, x8 connector, Full-height, Half-length
2CPU required
(Option) Add N8116-81 3rd Riser Card
Slot 7
PCIe 3.0 x8, x8 connector, Full-height, Full-length
2CPU required
Slot 8
PCIe 3.0 x8, x8 connector, Full-height, Half-length
2CPU required
NOTE:
By selecting PCI Riser Card, standard Riser can be exchanged and 2nd / 3rd Riser can be expanded. Refer to “7.1PCI Riser
Card for available Riser Card and detailed specifications
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Slot 8
LOM RAID
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 10
Server Configuration
1 Base Models
Product Name / Description
Part Number
NEC Express5800/R120h-2M 8x 2.5-inch Drive Model
No processor, no RAM, no HDD, no ODD, no Rail, no Power Supply Unit. Including : Front Bezel, 8x 2.5-inch Drive Cage, 1st Riser Card Kit, Standard Fan Kit
N8100-2562F
NEC Express5800/R120h-2M 8x 3.5-inch Drive Model
No processor, no RAM, no HDD, no ODD, no Rail, no Power Supply Unit. Including : Front Bezel, 8x 3.5-inch Drive Cage, 1st Riser Card Kit, Standard Fan Kit
N8100-2564F
NEC Express5800/R120h-2M 24x 2.5-inch Drive Model
No processor, no RAM, no HDD, no ODD, no Rail, no Power Supply Unit. Including : Front Bezel, 24x 2.5-inch Drive Cage, 1st Riser Card Kit, High Performance Fan Kit
N8100-2563F
NEC Express5800/R120h-2M 12x 3.5-inch Drive Model
No processor, no RAM, no HDD, no ODD, no Rail Including : Front Bezel, 12x 3.5-inch Drive Cage, 1st Riser Card Kit, High Performance Fan Kit
N8100-2565F
NOTE:
The base model must be ordered with a processor kit, a memory kit, a power supply kit and Rail.
2 Processors
Available sockets: 2
Category
Product Name / Description
Part Number
Bronze 3100
Xeon Bronze 3104 Processor Kit
Intel® Xeon ® Bronze 3104 (1.70 GHz, 6C/6T, 8.25MB, TDP 85W)
N8101-1191 (1st) N8101-1192 (2nd)
Xeon Bronze 3106 Processor Kit
Intel® Xeon ® Bronze 3106 (1.70 GHz, 8C/8T, 11MB, TDP 85W)
N8101-1193 (1st) N8101-1194 (2nd)
Silver 4100
Xeon Silver 4108 Processor Kit
Intel® Xeon ® Silver 4108 (1.80 GHz, 8C/16T, 11MB, TDP 85W)
N8101-1195 (1st) N8101-1196 (2nd)
Xeon Silver 4110 Processor Kit
Intel® Xeon ® Silver 4110 (2.10 GHz, 8C/16T, 11MB, TDP 85W)
N8101-1197 (1st) N8101-1198 (2nd)
Xeon Silver 4112 Processor Kit
Intel® Xeon ® Silver 4112 (2.60 GHz, 4C/8T, 8.25MB, TDP 85W)
N8101-1199 (1st) N8101-1200 (2nd)
Xeon Silver 4114 Processor Kit
Intel® Xeon ® Silver 4114 (2.20 GHz, 10C/20T, 13.75MB, TDP 85W)
N8101-1201 (1st) N8101-1202 (2nd)
Xeon Silver 4116 Processor Kit
Intel® Xeon ® Silver 4116 (2.10 GHz, 12C/24T, 16.50MB, TDP 85W)
N8101-1203 (1st) N8101-1204 (2nd)
Gold 5100
Xeon Gold 5115 Processor Kit
Intel® Xeon ® Gold 5115 (2.40 GHz, 10C/20T, 13.75MB, TDP 85W)
N8101-1205 (1st) N8101-1206 (2nd)
Xeon Gold 5118 Processor Kit
Intel® Xeon ® Gold 5118 (2.30 GHz, 12C/24T, 16.50MB, TDP 105W)
N8101-1207 (1st) N8101-1208 (2nd)
Xeon Gold 5120 Processor Kit
Intel® Xeon ® Gold 5120 (2.20 GHz, 14C/28T, 19.25MB, TDP 105W)
N8101-1209 (1st) N8101-1210 (2nd)
Xeon Gold 5122 Processor Kit
Intel® Xeon ® Gold 5122 (3.60 GHz, 4C/8T, 16.50MB, TDP 105W)
N8101-1211 (1st) N8101-1212 (2nd)
Gold 6100
Xeon Gold 6126 Processor Kit
Intel® Xeon ® Gold 6126 (2.60 GHz, 12C/24T, 19.25MB, TDP 125W)
N8101-1213 (1st) N8101-1214 (2nd)
Xeon Gold 6128 Processor Kit
Intel® Xeon ® Gold 6128 (3.40 GHz, 6C/12T, 19.25MB, TDP 115W)
N8101-1215 (1st) N8101-1216 (2nd)
Xeon Gold 6130 Processor Kit
Intel® Xeon ® Gold 6130 (2.10 GHz, 16C/32T, 22MB, TDP 125W)
N8101-1217 (1st) N8101-1218 (2nd)
Xeon Gold 6132 Processor Kit
Intel® Xeon ® Gold 6132 (2.60 GHz, 14C/28T, 19.25MB, TDP 140W)
N8101-1219 (1st) N8101-1220 (2nd)
Xeon Gold 6134 Processor Kit
Intel® Xeon ® Gold 6134 (3.20 GHz, 8C/16T, 24.75MB, TDP 130W)
N8101-1221 (1st) N8101-1222 (2nd)
Xeon Gold 6136 Processor Kit
Intel® Xeon ® Gold 6136 (3 GHz, 12C/24T, 24.75MB, TDP 150W)
N8101-1223 (1st) N8101-1224 (2nd)
Xeon Gold 6138 Processor Kit
Intel® Xeon ® Gold 6138 (2 GHz, 20C/40T, 27.50MB, TDP 125W)
N8101-1225 (1st) N8101-1226 (2nd)
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 11
Xeon Gold 6140 Processor Kit
Intel® Xeon ® Gold 6140 (2.30 GHz, 18C/36T, 24.75MB, TDP 140W)
N8101-1227 (1st) N8101-1228 (2nd)
Xeon Gold 6142 Processor Kit
Intel® Xeon ® Gold 6142 (2.60 GHz, 16C/32T, 22MB, TDP 150W)
N8101-1229 (1st) N8101-1230 (2nd)
Xeon Gold 6144 Processor Kit
Intel® Xeon ® Gold 6144 (3.50 GHz, 8C/16T, 24.75MB, TDP 150W)
N8101-1231 (1st) N8101-1232 (2nd)
Xeon Gold 6146 Processor Kit
Intel® Xeon ® Gold 6146 (3.20 GHz, 12C/24T, 24.75MB, TDP 165W)
N8101-1233 (1st) N8101-1234 (2nd)
Xeon Gold 6148 Processor Kit
Intel® Xeon ® Gold 6148 (2.40 GHz, 20C/40T, 27.50MB, TDP 150W)
N8101-1235 (1st) N8101-1236 (2nd)
Xeon Gold 6150 Processor Kit
Intel® Xeon ® Gold 6150 (2.70 GHz, 18C/36T, 24.75MB, TDP 165W)
N8101-1237 (1st) N8101-1238 (2nd)
Xeon Gold 6152 Processor Kit
Intel® Xeon ® Gold 6152 (2.10 GHz, 22C/44T, 30.25MB, TDP 140W)
N8101-1239 (1st) N8101-1240 (2nd)
Xeon Gold 6154 Processor Kit
Intel® Xeon ® Gold 6154 (3 GHz, 18C/36T, 24.75MB, TDP 200W)
N8101-1241 (1st) N8101-1242 (2nd)
Platinum 8100
Xeon Platinum 8153 Processor Kit
Intel® Xeon ® Platinum 8153 (2 GHz, 16C/32T, 22MB, TDP 125W)
N8101-1243 (1st) N8101-1244 (2nd)
Xeon Platinum 8156 Processor Kit
Intel® Xeon ® Platinum 8156 (3.60 GHz, 4C/8T, 16.50MB, TDP 105W)
NOTE:
- The processor kit is make-to-order product.
N8101-1245 (1st) N8101-1246 (2nd)
Xeon Platinum 8158 Processor Kit
Intel® Xeon ® Platinum 8158 (3 GHz, 12C/24T, 24.75MB, TDP 150W)
NOTE:
- The processor kit is make-to-order product.
N8101-1247 (1st) N8101-1248 (2nd)
Xeon Platinum 8160 Processor Kit
Intel® Xeon ® Platinum 8160 (2.10 GHz, 24C/48T, 33MB, TDP 150W)
N8101-1249 (1st) N8101-1250 (2nd)
Xeon Platinum 8164 Processor Kit
Intel® Xeon ® Platinum 8164 (2 GHz, 26C/52T, 35.75MB, TDP 150W)
N8101-1251 (1st) N8101-1252 (2nd)
Xeon Platinum 8168 Processor Kit
Intel® Xeon ® Platinum 8168 (2.70 GHz, 24C/48T, 33MB, TDP 205W)
NOTE:
- The processor kit is make-to-order product.
N8101-1253 (1st) N8101-1254 (2nd)
Xeon Platinum 8170 Processor Kit
Intel® Xeon ® Platinum 8170 (2.10 GHz, 26C/52T, 35.75MB, TDP 165W)
NOTE:
- The processor kit is make-to-order product.
N8101-1255 (1st) N8101-1256 (2nd)
Xeon Platinum 8176 Processor Kit
Intel® Xeon ® Platinum 8176 (2.10 GHz, 28C/56T, 38.50MB, TDP 165W)
NOTE:
- The processor kit is make-to-order product.
N8101-1257 (1st) N8101-1258 (2nd)
Xeon Platinum 8180 Processor Kit
Intel® Xeon ® Platinum 8180 (2.50 GHz, 28C/56T, 38.50MB, TDP 205W)
N8101-1259 (1st) N8101-1260 (2nd)
Gold 6100
Xeon Gold 6134M Processor Kit
Intel® Xeon ® Gold 6134M (3.20 GHz, 8C/16T, 24.75MB, TDP 130W)
NOTE:
- The processor kit is make-to-order product.
N8101-1261 (1st) N8101-1262 (2nd)
Xeon Gold 6140M Processor Kit
Intel® Xeon ® Gold 6140M (2.30 GHz, 18C/36T, 24.75MB, TDP 140W)
NOTE:
- The processor kit is make-to-order product.
N8101-1263 (1st) N8101-1264 (2nd)
Xeon Gold 6142M Processor Kit
Intel® Xeon ® Gold 6142M (2.60 GHz, 16C/32T, 22MB, TDP 150W)
NOTE:
- The processor kit is make-to-order product.
N8101-1265 (1st) N8101-1266 (2nd)
Platinum 8100
Xeon Platinum 8160M Processor Kit
Intel® Xeon ® Platinum 8160M (2.10 GHz, 24C/48T, 33MB, TDP 150W)
NOTE:
- The processor kit is make-to-order product.
N8101-1267 (1st) N8101-1268 (2nd)
Xeon Platinum 8170M Processor Kit
Intel® Xeon ® Platinum 8170M (2.10 GHz, 26C/52T, 35.75MB, TDP 165W)
NOTE:
- The processor kit is make-to-order product.
N8101-1269 (1st) N8101-1270 (2nd)
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 12
Xeon Platinum 8176M Processor Kit
Intel® Xeon ® Platinum 8176M (2.10 GHz, 28C/56T, 38.50MB, TDP 165W)
NOTE:
- The processor kit is make-to-order product.
N8101-1271 (1st) N8101-1272 (2nd)
Xeon Platinum 8180M Processor Kit
Intel® Xeon ® Platinum 8180M (2.50 GHz, 28C/56T, 38.50MB, TDP 205W)
NOTE:
- The processor kit is make-to-order product.
N8101-1273 (1st) N8101-1274 (2nd)
NOTE:
The processor kit for the 1st CPU must be ordered with a base model. The processors must be the same to configure dual processor system. The high performance CPU heatsink is shipped with the processor with 130 Watt or higher and Platinum 8156, Gold 6128, 5122.
The standard CPU heatsink is shipped with all other processors.
Estimated production lead time for the make-to-order processor kits will be approximately 3 months. When using 4 slots(Except LOM slot and RAID slot), it is necessary to purchase the 2nd riser card option after setting it to 2 CPU
configuration
The maximum number of logical processors supported by OS
See the table below for the maximum number of logical processors that you can actually use on your system.
Operating Systems
Number of Logical
Processors Supported
by Operating Systems
Maximum Available
Number of Logical
Processors
Microsoft Windows Server 2012 R2 Standard Microsoft Windows Server 2012 R2 Datacenter
640 1
112
Microsoft Windows Server 2016 Standard Microsoft Windows Server 2016 Datacenter
640 1
112
Red Hat Enterprise Linux 7
384
112
VMware ESXi 6.0
480
112
VMware ESXi 6.5
576
112
1
The maximum numbers of logical processors when using Hyper-V are below:
- Windows Server 2012 R2: 320
- Windows Server 2016: 512
Maximum memory capacity
Maximum available memory capacity depends on the type of processor, see below.
CPU
Maximum memory capacity per
CPU
Processors containing an Min the model
Xeon ® Platinum 8160M, 8170M, 8176M, 8180M Xeon ® Gold 6134M, 6140M, 6142M
1.5TB
Others
768GB
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 13
3 Memory
3.1 Memory Configuration Feature Comparison
See the table below for feature comparisons of memory configurations supported.
Independent Channel
Memory Sparing
Memory Mirroring
Performance
Best
Better
Good
Data Protection
No
Multiple single bit error protection
Multiple single bit and multi bit error protection
Redundancy
No
Partly
Fully
Data Correction
ECC, x4 SDDC
ECC, x4 SDDC
ECC, x4 SDDC
Available Memory
Full physical memory
Two ranks of memory per channel : Half physical memory Four ranks of memory per channel : 3/4 physical memory Eight ranks of memory per channel : 7/8 physical memory
Half physical memory
Available Memory Channels
6 6 6
Notes
-
All DIMMs in the system must be identical.
All DIMMs in the system must be identical.
NOTE:
Single Rank Memory (N8102-708/-709) does not support Memory Mirroring Mode Configuration Service. Refer to “10.2 Memory RAS Settings”
3.2 Memory
Available slots: 12 per processor
Category
Product Name / Description
Part Number
Registered DIMM (RDIMM)
8GB DDR4-2666 REG Memory Kit (1x8GB/SR)
1 x 8GB Registered ECC DIMM, DDR4-2666(PC4-2666), Single Rank
N8102-708
16GB DDR4-2666 REG Memory Kit (1x16GB/SR)
1 x 16GB Registered ECC DIMM, DDR4-2666(PC4-2666), Single Rank
N8102-709
16GB DDR4-2666 REG Memory Kit (1x16GB/DR)
1 x 16GB Registered ECC DIMM, DDR4-2666(PC4-2666), Dual Rank
N8102-710
32GB DDR4-2666 REG Memory Kit (1x32GB/DR)
1 x 32GB Registered ECC DIMM, DDR4-2666(PC4-2666), Dual Rank
N8102-711
Load Reduced DIMM (LRDIMM)
64GB DDR4-2666 LR Memory Kit (1x64GB/QR)
1 x 64GB Load Reduced ECC DIMM, DDR4-2666(PC4-2666), Quad Rank
N8102-712
128GB DDR4-2666 LR Memory Kit (1x64GB/OR)
1 x 128GB Load Reduced ECC DIMM, DDR4-2666(PC4-2666), Octal Rank
N8102-713
NOTE:
Minimum one memory kit per processor must be installed. It is recommended to install memory kits in multiples of 6 identical DIMMs for 6-channel symmetric memory configurations to
increase memory transfer speed.
Mix configurations of RDIMM and LRDIMM are not supported. Do NOT mix LRDIMM 64GB with LRDIMM 128GB. If you install more than six times N8102-713 128GB DDR4-2666 LR Memory Kit, you require one of the following CPU Processor
codes containing an M (N8101-1261/-1262/-1263/-1264/-1265/-1266/-1267/-1268/-1269/-1270/-1271/-1272/-1273/-1274)
See page 43 for additional memory configuration information
Maximum Memory Speed
See the table below for the actual maximum memory transfer speed. DDR4 memory speed depends on the native memory bus speed of the processor.
Processor Type
DIMM Speed
Xeon ® Platinum 8100 series Xeon ® Gold 6100 series Xeon ® Gold 5122 Processor
2666 MHz
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 14
Xeon ® Gold 5100 series excluding Xeon ® Gold 5122 Processor Xeon ® Silver 4100 series
2400 MHz Xeon ® Bronze 3100 series
2133 MHz
Maximum Available Memory
See the table below for the maximum memory size that you can actually use on your system.
Operating Systems
Maximum Memory Size Supported by Operating Systems
Maximum Available Memory
Microsoft Windows Server 2012 R2 Standard1 Microsoft Windows Server 2012 R2 Datacenter1
4 TB
3 TB
Microsoft Windows Server 2016 Standard
1
Microsoft Windows Server 2016 Datacenter1
24 TB
3 TB
Red Hat Enterprise Linux 7
12TB
3 TB
VMware ESXi 6.02
6 TB
3 TB
VMware ESXi 6.53
12 TB
3 TB
1
The maximum available memory size of Hyper-V systems is below:
- Windows Server 2012 R2 : 4 TB
- Windows Server 2016 : 24 TB
2
Up to 4 TB of the main memory is available to each virtual machine.
3
Up to 6 TB of the main memory is available to each virtual machine.
4 Internal Storage
Drive Bay Configuration
Choose appropriate drive model and optional drive cages in accordance with the type and number of the drive you want to install.
List of the number that Internal Drives can be mounted
Category
Front Cage
Rear Cage
Middle Cage (Built in standard Riser Card )
Inside the server (Mounted on Standard Riser Card
1,2
)
8x 2.5-inch Drive Cage1
Standard :
8x 2.5-inch SAS/SATA Drive
Expansion:
8x2.5-inch SAS/SATA Drive
(Up to 1)
Internal DVD Drive Kit (Up to 1)
Standard: ­Expansion:
2x2.5-inch SAS/SATA Drive (Up to 3)
Standard: ­Expansion: -
Standard: 2xM.2 SATA
SSD 5
24x
2.5-inch Drive Cage2
Standard:
24x2.5-inch Drive
Expansion: -
8x 3.5-inch Drive Cage3
Standard :
8x3.5-inch SAS/SATA Drive Expansion: 2x2.5-inch SAS/SATA Drive (Up to 1)
Standard: ­Expansion:
2x2.5-inch SAS/SATA Drive (Up to 3) 3x3.5-inch SAS/SATA
Drive (Up to 1)
Standard: ­Expansion:
4x3.5-inch
SAS/SATA Drive
(Up to 1) 12x
3.5-inch Drive Cage4
Standard: 12x3.5-inch SAS/SATA Drive Expansion: -
1
Up to 24 2.5-inch Drive Cage can be mounted
2
Up to 30 2.5-inch Drive Cage can be mounted.
3
Up to 15 3.5-inch Drive Cage can be mounted.In addition, one 2x 2.5-inch Drive Cage can be mounted.
4
Up to 19 3.5-inch Drive Cage can be mounted.In addition, one 2x 2.5-inch Drive Cage can be mounted.
5
Up to two M.2 SATA SSDs can be installed using the standard 1st riser card. However, you cannot install M.2 SATA SSD in the optional 1st riser card. Also, it is impossible to connect RAID controller to M.2 SATA SSD.
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 15
Front Drive Bay
Drive Bay for 8x 2.5-inch Drive Model
Eight 2.5-inch drive bays are standard. With optional 2.5-inch drive cages, up to 18 2.5-inch drive bays can be equipped.
The order of mounting the optional Drive Cage is 2 1.
Drive Bay for 24x 2.5-inch Drive Model
24 2.5-inch drive bays are standard.
Drive Bay for 8x 3.5-inch Drive Model
Eight 3.5-inch drive bays are standard. With an optional 2.5-inch drive cage, two 2.5-inch drive bays can be added.
Drive Bay for 12x 3.5-inch Drive Model
Twelve 3.5-inch drive bays are standard.
NOTE:
In default factory configuration, there are some conditions of drive types and RAID levels can be installed. Refer to “Condition of
internal drives in default factory configuration.” in References
Up to 10 drives can be installed in Non-RAID (Embedded SATA) configuration.
Refer to “Conditions for mixing of Internal Drives” in References.
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 16
8x 2.5-inch Drive Model
Category
Product Name / Description
Part Number
Front
Drive Cage 3
8x2.5-inch Hot Plug Drive Cage Kit(SAS/SATA)
8x 2.5-inch SAS/SATA HDD For 8x 2.5-inch Drive Model
(Standard)
Drive Cage 2
8x2.5-inch Hot Plug Drive Cage Kit(SAS/SATA)
8x 2.5-inch SAS/SATA HDD For 8x 2.5-inch Drive Model
NOTE:
- N8154-94 can be installed in Drive cage 2 only.
N8154-94
Drive Cage 1
Internal DVD Drive Installation Kit
Equipping with one optical drive bay, one drive cage bay for 2x
2.5-inch Drive Cage, two USB connectors, and one Display port. For 8x 2.5-inch Drive Model
N8154-117
NOTE:
If N8154-95 2x2.5-inch Hot Plug Drive Cage Kit (SAS/SATA/PCIe SSD) and N8154-117 Internal DVD Drive Installation Kit are
selected, N8154-95 2x2.5-inch Hot Plug Drive Cage Kit (SAS/SATA/PCIe SSD) is preferentially installed in N8154-117 Internal DVD Drive Installation Kit.
Up to 8 drives can be installed in Non-RAID (Embedded SATA) configuration. Refer to “Conditions for mixing of Internal Drives” in References.
8x 3.5-inch Drive Model
Category
Product Name / Description
Part Number
2x2.5-inch Hot Plug Drive Cage Kit(SAS/SATA)
2x 2.5-inch SAS/SATA HDD For 8x 3.5-inch Drive Model
N8154-96
Optional Rear Drive Bay
Rear Drive Bay for all Drive Models
Category
Product Name / Description
Part Number
Rear (/ Front)
Drive Cage 6
2x2.5-inch Hot Plug Drive Cage Kit(SAS/SATA/PCIe SSD)
Drive bay for 2x 2.5-inch SAS/SATA HDD/ PCIe SSD Up to 2 cages can be installed. For all Drive models
N8154-95
Rear
Drive Cage 4/5
2x2.5-inch Hot Plug Drive Cage Kit(SAS/SATA, Rear)
Drive bay for 2x 2.5-inch SAS/SATA HDD, including Riser card for slot 3 or 6 with one PCIe 3.0 (x16) Up to 2 cages can be installed. For all Drive models
N8154-98
NOTE:
If Rear Drive Cage is selected, N8181-158 High Performance Fan Kit is needed. However, in the configuration where a high
-performance fan is attached to CPU, it is unnecessary to select it.
If you order two N8154-95 2x2.5-inch Hot Plug Drive Cage Kit (SAS/SATA/PCIe SSD), N8154-117 Internal DVD Drive Installation
Kit is required. If one N8154-95 2x2.5-inch Hot Plug Drive Cage Kit is selected with N8154-117 Internal DVD Drive Installation Kit, the Drive Cage is preferentially installed in N8154-117 Internal DVD Drive Installation Kit mounted on Drive Cage 1 (Option). If one N8154-95 2x2.5-inch Hot Plug Drive Cage Kit is selected without N8154-117 Internal DVD Drive Installation Kit, the Drive Cage can be installed in Rear Drive Cage6 instead of 3rd PCI Riser Kit.
The N8154-98 2x2.5-inch Hot Plug Drive Cage Kit can be installed instead of 1st or 2nd PCI Riser Kit. If the Drive Cage Kit is
installed, 1st or 2nd Riser Card Kit cannot be installed.
If the N8154-98 2x2.5-inch Hot Plug Drive Cage Kit (SAS/SATA, Rear) is installed on 2nd Riser, not allowed to install 3rd Riser.
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 17
Drive Bay for 3.5-inch Drive Model
With an optional 2.5-inch and 3.5-inch drive cage instead of PCI Riser Card Kit, two 2.5-inch drive bays and three 3.5-inch drive bays can be added.
Category
Product Name / Description
Part Number
Rear
Drive Cage 4
2x2.5-inch Hot Plug Drive Cage Kit(SAS/SATA, Rear)
2x 2.5-inch SAS/SATA HDD, including Riser card for slot 3 with one PCIe 3.0 x16 slot For all Drive Models
N8154-98
Drive Cage 7
3x3.5-inch Hot Plug Drive Cage Kit(SAS/SATA, Rear)
3x 3.5-inch SAS/SATA HDD For 8x3.5-inch Drive Model and 12x3.5-inch Drive Model
N8154-99
NOTE:
N8154-99 3x3.5-inch Hot Plug Drive Cage Kit (SAS/SATA, Rear) can be installed instead of 2nd, 3rd PCI Riser Kit and N8177-09
Optional RS-232C connector Kit. If the Drive Cage Kit is installed, 2nd, 3rd PCI Riser Kit or N8177-09 Optional RS-232C connecter Kit cannot be installed.
After mounting N8154-99, N8154-98 2x2.5-inch Hot Plug Drive Cage Kit (SAS/SATA, Rear) can be installed instead of 1st PCI
Riser Kit. If the Drive Cage Kit is installed, 1st Riser Card Kit cannot be installed.
When N8154-99 3x3.5-inch Hot Plug Drive Cage Kit (SAS/SATA, Rear) is installed, only one N8154-98 2x2.5-inch Hot Plug Drive
Cage Kit (SAS/SATA, Rear) can be installed.
If Rear Drive Cage is selected, N8181-158 High Performance Fan is needed. However, in the configuration where a
high-performance fan is attached to CPU, it is unnecessary to select it.
Optional Midplane Drive Bay for 3.5-inch Drive Model
With an optional drive cage installed inside chassis, four 3.5-inch drive bay can be equipped.
Category
Product Name / Description
Part Number
Inside
4x3.5-inch Hot Plug Drive Cage Kit(SAS/SATA, Mid)
Including two low profile heatsink For 8x3.5-inch Drive Model and 12x3.5-inch Drive Model
N8154-100
NOTE:
Processor with 125 Watt or less are supported and High Performance Fan Kit are required. Platinum 8156 and Gold 6128, 5122 processors are not supported. Only half-length PCI cards can be installed. The heatsink included with the kit must be installed. In default factory configuration the heatsink installed automatically, not allowed
to select the high-performance heatsink instead.
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 18
To install the rear drive bay, N8181-158 High Performance Fan Kit must be installed. If this kit is included in the base model or
some specific CPUs, it is not necessary to add this.
To operate drive insertion/removal, the system must be turned off.
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 19
Storage Controllers and Options
Configuration selection of RAID
Please select according to function and performance. The following is an example of the configuration
Configuration
Maximum mountable number
RAID function
Support OS
Single connection
10(3.5-inch Drive Model) 8(2.5-inch Drive Model)
Non
Windows Server 2012 R2 Windows Server 2016
On-board RAID
10(3.5-inch Drive Model) 8(2.5-inch Drive Model)
RAID 0/1/10
Windows Server 2012 R2 Windows Server 2016
Internal RAID Controller(8 port)
8
RAID 0/1/5/6/10/50/60
Windows Server 2012 R2 Windows Server 2016 Red Hat Enterprise Linux
6.9 Red Hat Enterprise Linux 7 VMware ESXi 6.0 Update3
VMware ESXi 6.5 Update1
Internal RAID Controller (8 port)
+ SAS Expander Card
26 Internal RAID Controller (16 port)
16
Internal RAID Controller (16 port)
+ SAS Expander Card
30
List of the configuration for Internal Drive and RAID
Category
Front Cage
Rear Cage
Middle Cage (Inside the server )
Inside the server (Mounted on Standard Riser Card)
8x 2.5-inch Drive Cage1
Standard :
8x 2.5-inch SAS/SATA Drive Expansion:
8x2.5-inch SAS/SATA Drive
(Up to 1)
Internal DVD Drive Kit (Up to 1)
Standard: ­Expansion:
2x2.5-inch SAS/SATA
Drive (Up to 3)
2 3
Standard: ­Expansion: -
Standard: 2x M.2 SATA SSD 6
24x
2.5-inch Drive Cage
2,4
Standard:
24x2.5-inch Drive
Expansion: -
8x 3.5-inch Drive Cage3
Standard :
8x 3.5-inch SAS/SATA Drive Expansion: 2x2.5-inch SAS/SATA Drive (Up to 1)
Standard: ­Expansion:
2x2.5-inch SAS/SATA Drive (Up to 3) 3x3.5-inch SAS/SATA Drive (Up to 1) 2
Standard: ­Expansion:
4x3.5-inch
SAS/SATA Drive
(Up to 1) 2 12x
3.5-inch Drive Cage5
Standard: 12x x 3.5-inch SAS/SATA Drive Expansion: -
1
Up to 8 SATA Drive can be connected in the single connection and On-board RAID configurations.
2
In factory installation, if Rear Cage or Middle Cage is selected, Internal RAID Controller and SAS Expander Card is necessary.
3
In factory installation, if 24 Drives in Front Cage and 2 or more drives in Rear Cage is selected, Internal RAID Controller with 16 ports and SAS Expander Card are needed.
4
In factory installation for 24x 2.5-inch Drive Model, Internal RAID Controller and SAS Expander Card are needed. However, it is
unnecessary in the case under the following conditions, * No OS pre-installation * No Rear Cage installed
* N8103-191 RAID Controller (4GB, RAID 0/1/5/6) selected.
* 16 or fewer Drives
5
In factory installation, if 12x3.5-inch Drive Model is selected, Internal RAID Controller with 16 ports is needed.
6
M.2 SATA SSD slot is single connection or On-board RAID configurations regardless of the presence or absence of RAID Controller. M.2 SATA SSD cannot be connected to RAID Controller.
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 20
Embedded SATA Controller
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
10 x 6Gb/s SATA drive, 2x M.2 drive
(Standard)
Cable
Internal SATA Cable
(Standard)
NOTE:
8 ports for SATA drives and two ports for M.2 drives are available on 2.5-inch Drive Model. 10 ports for SATA drives and two ports for M.2 drives are available on 3.5-inch Drive Model. Hot plug insertion/removal are not supported in the configuration.
Embedded SATA RAID Controller (RAID 0/1/10)
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
10 x 6Gb/s SATA, 2x M.2
(Standard)
Cable
Internal SATA Cable
(Standard)
NOTE:
8 ports for SATA drives and two ports for M.2 drives are available on 2.5-inch Drive Model. 10 ports for SATA drives and two ports for M.2 drives are available on 3.5-inch Drive Model. For factory installation, up to 8 drives can be installed in the system in 2.5-inch Drive Model. For factory installation, up to 10 drives can be installed in the system in 3.5-inch Drive Model. The Embedded SATA RAID Controller is available for Windows operating system only. When you use the Embedded SATA RAID controller, choose an external DVD drive. An internal DVD drive requires the embedded
SATA controller configuration.
RAID Controller for Dedicated PCI Slot
Choose the appropriate RAID controller in accordance with RAID feature required, the number of drives to install.
Category
Product Name / Description
Part Number
Storage Controller
8 Port / Standard Heatsink
RAID Controller (RAID 0/1)
RAID 0/1/5/10 and SAS HBA mode, 0MB, Int. 8 port, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s, Standard Heatsink
N8103-189
RAID Controller (2GB, RAID 0/1/5/6)
RAID 0/1/5/6/10/50/60, 2GB, Int. 8 port, PCIe 3.0 x8, SAS 12Gb/s, SATA, 6Gb/s, Standard Heat Sink
N8103-190
16 Port / Standard Heatsink
RAID Controller (4GB, RAID 0/1/5/6)
RAID 0/1/5/6/10/50/60, 4GB, Int. 16 port, PCIe 3.0 x8, SAS 12Gb/s, SATA, 6Gb/s, Standard Heatsink
N8103-191
Battery Backup
Battery Backup Unit
Lithium-ion Battery is needed for N8103-190/-191/-196/-201 RAID controller.
N8103-198
Expander Card
SAS Expander Card
PCI card form factor, Int. 36, SAS 12Gb/s
NOTE:
- The card is required when you install the number of SAS drives that
exceeds the number of the internal ports of a RAID controller.
- Up to 26 drives can be connected with a SAS Expander Card.
N8103-191 RAID controller is required to install 27 drives and more.
N8116-51
NOTE:
One battery backup unit must be installed per system. N8103-189 supports RAID5. If higher performance is needed, choose RAID controller with cache memory.
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 21
RAID Controller for Standard PCI Slot
Category
Product Name / Description
Part Number
Storage Controller
RAID Controller (RAID 0/1)
RAID 0/1/5/10 and SAS HBA mode, 0MB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-195
RAID Controller (2GB, RAID 0/1/5/6)
RAID 0/1/5/6/10/50/60, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-201
Battery Backup
Battery Backup Unit
Lithium-ion Battery for N8103-190/-191/-196/-201 RAID controller. 1 battery provides power to all RAID controller.
N8103-198
Expander Card
SAS Expander Card
PCI card form factor, Int. 36, SAS 12Gb/s, SATA 6Gb/s
NOTE:
- The card is required when you install the number of SAS drives that
exceeds the number of the internal ports of a RAID controller.
N8116-51
Cable
Internal SAS/SATA Cable
NOTE:
Cable for RAID controller (PCI slot) to front Drive Cage and Expander Card.
K410-378(00)
NOTE:
The RAID controller must be installed after shipment. One battery backup unit must be installed per system. N8103-195 supports RAID5. If higher performance is needed, choose RAID controller with cache memory.
Internal Drives
2.5-inch SATA Hard Disk Drives
Category
Product Name / Description
Part Number
512e Sector
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512e sector
N8150-545
NOTE:
512e sector drives are not available for VMware ESXi 6.0 system. All drives within a RAID array should be of the same capacity. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.
2.5-inch SATA Solid State Drives
Category
Product Name / Description
Part Number
Read Intensive DWPD 1
240GB Hot Plug 2.5-inch SATA SSD
1 x 240GB SATA SSD, 2.5-inch, 6Gb/s, 512n sector, Read Intensive
N8150-743
480GB Hot Plug 2.5-inch SATA SSD
1 x 480GB SATA SSD, 2.5-inch, 6Gb/s, 512n sector, Read Intensive
N8150-744
960GB Hot Plug 2.5-inch SATA SSD
1 x 960GB SATA SSD, 2.5-inch, 6Gb/s, 512n sector, Read Intensive
N8150-745
1.92TB Hot Plug 2.5-inch SATA SSD
1 x 1.92TB SATA SSD, 2.5-inch, 6Gb/s, 512n sector, Read Intensive
N8150-746
3.84TB Hot Plug 2.5-inch SATA SSD
1 x 3.84TB SATA SSD, 2.5-inch, 6Gb/s, 512n sector, Read Intensive
N8150-747
Value Endurance DWPD 3
240GB Hot Plug 2.5-inch SATA SSD
1 x 240GB SATA SSD, 2.5-inch, 6Gb/s, 512n sector, Value Endurance
N8150-739
480GB Hot Plug 2.5-inch SATA SSD
1 x 480GB SATA SSD, 2.5-inch, 6Gb/s, 512n sector, Value Endurance
N8150-740
960GB Hot Plug 2.5-inch SATA SSD
1 x 960GB SATA SSD, 2.5-inch, 6Gb/s, 512n sector, Value Endurance
N8150-741
1.92TB Hot Plug 2.5-inch SATA SSD
1 x 1.92TB SATA SSD, 2.5-inch, 6Gb/s, 512n sector, Value Endurance
N8150-742
NOTE:
All drives within a RAID array should be of the same capacity.
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 22
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.
2.5-inch SAS Hard Disk Drives
Category
Product Name / Description
Part Number
512n Sector / 10,000 rpm
300GB Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-546
600GB Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-547
1.2TB Hot Plug 2.5-inch SAS HDD
1 x 1.2TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-549
512e Sector / 10,000 rpm
1.8TB Hot Plug 2.5-inch SAS HDD
1 x 1.8TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512e sector
N8150-550
512n Sector / 15,000 rpm
300GB 15K Hot Plug 2.5-inch SAS HDD
1x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
N8150-551
600GB 15K Hot Plug 2.5-inch SAS HDD
1x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
N8150-552
512e Sector / 15,000 rpm
900GB 15K Hot Plug 2.5-inch SAS HDD
1x 900 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512e sector
N8150-553
NOTE:
512e sector drives are not available for VMware ESXi 6.0 system. All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SATA SSDs and SAS SSDs can be mixed. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.
2.5-inch SAS Solid State Drives
Category
Product Name / Description
Part Number
Middle Endurance DWPD 10
400GB Hot Plug 2.5-inch SAS SSD
1 x 400GB SAS SSD, 2.5-inch, 12Gb/s, 512n sector, Middle Endurance
N8150-748
800GB Hot Plug 2.5-inch SAS SSD
1 x 800GB SAS SSD, 2.5-inch, 12Gb/s, 512n sector, Middle Endurance
N8150-749
Value Endurance DWPD 3
400GB Hot Plug 2.5-inch SAS SSD
1 x 400GB SAS SSD, 2.5-inch, 12Gb/s, 512n sector, Value Endurance
N8150-750
800GB Hot Plug 2.5-inch SAS SSD
1 x 800GB SAS SSD, 2.5-inch, 12Gb/s, 512n sector, Value Endurance
N8150-751
Read Intensive DWPD 1
480GB Hot Plug 2.5-inch SAS SSD
1 x 480GB SAS SSD, 2.5-inch, 12Gb/s, 512n sector, Read Intensive
N8150-752
960GB Hot Plug 2.5-inch SAS SSD
1 x 960GB SAS SSD, 2.5-inch, 12Gb/s, 512n sector, Read Intensive
N8150-753
NOTE:
All drives within a RAID array should be of the same capacity. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.
3.5-inch SATA Hard Disk Drives
Category
Product Name / Description
Part Number
512n Sector
1TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-554
2TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-555
4TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-557
512e Sector
6TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 6 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512e sector
N8150-558
8TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 8 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512e sector
N8150-559
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 23
10TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 10 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512e sector
N8150-560
NOTE:
512e sector drives are not available for VMware ESXi 6.0 system. All drives within a RAID array should be of the same type, capacity. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.
3.5-inch Near Line SAS Hard Disk Drives
Category
Product Name / Description
Part Number
512e Sector
8TB 7.2K Hot Plug 3.5-inch SAS HDD
1 x 8 TB Near Line SAS HDD, 3.5-inch, 12Gb/s, 7,200 rpm, 512e sector
N8150-562
10TB 7.2K Hot Plug 3.5-inch SAS HDD
1 x 10 TB Near Line SAS HDD, 3.5-inch, 12Gb/s, 7,200 rpm, 512e sector
N8150-563
NOTE:
512e sector drives are not available for VMware ESXi 6.0 system. All drives within a RAID array should be of the same capacity. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.
Near Line SAS HDD (7200 rpm) and SAS-HDD (10,000rpm / 15,000rpm) are the same in maximum transfer speed and error
recovery capabilities, however the Near Line SAS HDD and SATA HDDs(7.200rpm) are the same in I/O performance and life.
M.2 SATA Solid State Drives
Category
Product Name / Description
Part Number
Read Intensive
150GB Non-hot-plug M.2 SATA SSD
1 x 150 GB M.2 SATA SSD, Read Intensive
N8150-778
NOTE:
Optional riser card kit with M.2 connector is required. The M.2 SATA SSD uses an Embedded SATA controller (Single connection or On-board RAID configuration) regardless of whether
an optional RAID controller is installed.
5 Optical Drive
Category
Product Name / Description
Part Number
Internal
Installation Kit
Internal DVD Drive Installation Kit
Equipping with one optical drive bay, one drive cage bay for 2x 2.5-inch Drive Cage, two USB connectors, and one VGA connector For 8x 2.5-inch Drive Model
NOTE:
- The kit must be installed in the device bay 1.
N8154-117
Drive
Internal Slim DVD-ROM drive
Slim DVD-ROM drive
N8151-137
Internal DVD-Super Multi Drive
Slim DVD Super Multi drive, including writing software
NOTE:
- Not supported for Linux or VMware
N8151-138
External
External DVD-ROM Drive
Slim DVD-ROM drive, USB bus powered, 1.6A require, USB
N8160-102
NOTE:
If N8151-137/-138 Internal Slim DVD-ROM drive/ Internal DVD-Super Multi Drive selected, N8154-117 Internal DVD Drive
Installation Kit is needed.
An internal optical drive is shipped separately if you order it with 8x 3.5-inch Drive Model. T-10 and T-15 Torx screwdriver is
required to install an optical drive into the server.
When the Embedded SATA RAID controller is used, choose an external DVD-ROM drive. Internal DVD drive cannot be installed in 24x2.5-inch Drive Model or 12x3.5-inch Drive Model, choose an external DVD-ROM drive.
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 24
6 Flash FDD
Choose the Flash FDD if you need to prepare an alternative device for a floppy drive.
Product Name / Description
Part Number
Flash FDD
USB flash emulating USB floppy disk, Native capacity 1.44 MB
N8160-96
NOTE:
Up to one drive can be connected.
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 25
7 PCI Riser Card /PCI Card
Up to three PCI riser cards can be installed in the system and 1st riser card is installed as standard. Up to three PCI cards can be mounted on the 1st riser card, to be install four or more PCI cards, 2nd and 3rd PCI riser card is required. HDD cage is required for HDD installation
Please refer to Support PCI Cards and Installable Slots with regards to the position of PCI slot
Rear Image (with PCI Riser only)
Rear Image (with 3x2.5”drive cage)
Rear Image (with 1x2.5drive cage and 1x3.5 drive cage)
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 26
PCI Riser Card
The system supports many kind of the PCI slot configuration. Choose the appropriate configuration in accordance with the type of PCI cards you want to install and whether you need M.2 .slots.
1st PCI Riser Card Kit
Product Name / Description
Figure
Part Number
1st Riser Card(3xPCI)
Riser card for slot 1 to 3 with one PCIe 3.0 x16 slot, two PCIe 3.0 x8 slots, and two M.2 SATA connectors
(Standard)
1st Riser Card Kit (2xPCI + 1xGPU Installation Kit)
Riser card for slot 2 to 3 with two PCIe 3.0 x16 slots, one power connector for GPU, and support bracket for a dual-slot PCI card.
NOTE:
- The Riser Card Kit is a factory installation option.
N8116-66
1st Riser Card Kit(2xPCI)
Riser card for slot 1 to 2 with two PCIe 3.0 x16 slots
NOTE:
- The Riser Card Kit is a factory installation option.
N8116-64
2x2.5-inch Hot Plug Drive Cage Kit(SAS/SATA, Rear)
Riser card for slot 3 or 6 with one PCIe 3.0 x16 slot, including 2x 2.5-inch drive bay to install into slot 1 to 2 or 4 to 5
N8154-98
NOTE:
N8116-66/-64 are factory installation options, not allow to be ordered after shipment. If N8154-98 cage is selected, it must be installed in 1st PCI slot by factory installation. Refer to “Optional Rear Drive Bayin detail
2nd PCI Riser Card Kit
Product Name / Description
Figure
Part Number
2nd Riser Card Kit(3xPCI + 1xGPU Installation Kit)
Riser card for slot 4 to 6 with one PCIe 3.0 x16 slot, two PCIe 3.0 x8 slot, and one power connector for GPU
N8116-62
2nd Riser Card Kit (2xPCI + 1xGPU Installation Kit)
Riser card for slot 5 to 6 with two PCIe 3.0 x16 slot, one power connector for GPU, and support bracket for a dual-slot PCI card.
N8116-67
2nd Riser Card Kit(2xPCI)
Riser card for slot 4 to 5 with two PCIe 3.0 x16 slots
N8116-56
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 27
2x2.5-inch Hot Plug Drive Cage Kit(SAS/SATA, Rear)
Riser card for slot 3 or 6 with one PCIe 3.0 x16 slot, including 2x 2.5-inch drive bay to install into slot 1 to 2 or 4 to 5
N8154-98
NOTE:
To use PCI slot 4 to 6, dual-processor configuration is required. If the N8154-98 2x2.5-inch Hot Plug Drive Cage Kit (SAS/SATA, Rear) is installed on 2nd Riser, it is not allowed to install 3rd Riser.
Refer to 4.1.4Optional Rear Drive Bay in detail.
3rd PCI Riser Card Kit
Product Name / Description
Figure
Part Number
3rd Riser Card Kit(1xPCI, 1xGPU Installation Kit)
Riser card for slot 7 with one PCIe 3.0 x16, one power connector for GPU, and support bracket for a dual-slot PCI card
N8116-78
3rd Riser Card Kit(2xPCI)
Riser card for slot 7 to 8 with two PCIe 3.0 x8 slots
N8116-81
NOTE:
Dual-processor configuration is required. 2nd PCI Riser Card Kit (N8116-62/-67/-56) is required to install 3rd Riser Card Kit. If you order two N8154-95 2x2.5-inch Hot Plug Drive Cage Kit (SAS/SATA/PCIe SSD), N8154-117 Internal DVD Drive Installation
Kit is required. If one N8154-95 2x2.5-inch Hot Plug Drive Cage Kit is selected with N8154-117 Internal DVD Drive Installation Kit, the Drive Cage is preferentially installed in N8154-117 Internal DVD Drive Installation Kit mounted on Drive Cage 1 (Option). If one N8154-95 2x2.5-inch Hot Plug Drive Cage Kit is selected without N8154-117 Internal DVD Drive Installation Kit, the Drive Cage can be installed in Rear Drive Cage6 instead of 3rd PCI Riser Kit.
The 3rd PCI Riser Card Kit is not available if the N8154-95 2x 2.5-inch Drive Cage Kit is installed into slot 7 to 8. If N8154-98 2x2.5-inch Hot Plug Drive Cage Kit (SAS/SATA, Rear) are selected in 2nd Riser, 3rd Riser Card can’t be added to
Riser Card.
Network Interface Controller
Category
Product Name / Description
Part Number
LOM Card
1GbE
Quad Port 1000BASE-T LOM Card
Broadcom BCM5719 PCIe 2.0(x4)
N8104-171
Quad Port 1000BASE-T LOM Card
Intel Ethernet Controller I350 PCIe 2.0(x4)
N8104-172
10GbE
Dual Port 10GBASE-T LOM Card
QLogic 57810S PCIe 2.0(x8)
N8104-173
Dual Port 10GBASE-T LOM Card
Intel X550
PCIe 3.0(x4)
N8104-175
Dual Port 10GBASE SFP+ LOM Card
Intel Ethernet Controller X710 PCIe 3.0(x8)
NOTE:
- N8104-189 SFP+ Module is required to connect with an optical cable.
- Up to two SFP+ Modules can be installed.
N8104-176
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 28
- Twinax cable can be installed.
25GbE
Dual Port 25GBASE SFP+ LOM Card
Cavium 45604 PCIe 3.0(x16)
NOTE:
- N8104-190 SFP+ Module is required to connect with an optical cable.
- Up to 2 SFP+ Modules can be installed.
- Twinax cable can be installed
N8104-177
Adapter
1GbE
Dual Port 1000BASE-T Adapter
Broadcom BCM5720 Gigabit Ethernet Controller PCIe 2.0(x1)
N8104-178
Dual Port 1000BASE-T Adapter
Intel Ethernet Controller I350 PCIe 2.0(x4)
NOTE:
- Network cables with RJ-45 plug covers cannot be used.
N8104-180
Quad Port 1000BASE-T Adapter
Broadcom BCM5719 Gigabit Ethernet Controller PCIe 2.0(x4)
NOTE:
- Network cables with RJ-45 plug covers cannot be used.
N8104-179
Quad Port 1000BASE-T Adapter
Intel Ethernet Controller I350 PCIe 2.0(x4)
NOTE:
- Network cables with RJ-45 plug covers cannot be used.
N8104-181
10GbE
Dual Port 10GBASE-T Adapter
QLogic 57810S PCIe 2.0(x8)
N8104-182
Dual Port 10GBASE-T Adapter
Cavium QL41401, PCIe3.0(x8)
N8104-183
Dual Port 10GBASE-T Adapter
Intel X550-AT2, PCIe3.0(x4)
N8104-184
Dual Port 10GBASE SFP+ Adapter
QLogic 57810S PCIe 2.0(x8)
NOTE:
- N8104-189 SFP+ Module is required to connect with an optical cable.
- Up to 2 SFP+ Modules can be installed.
- Twinax cable can be installed
N8104-185
Dual Port 10GBASE SFP+ Adapter
Intel Ethernet Controller X710 PCIe 3.0(x8)
NOTE:
- N8104-189 SFP+ Module is required to connect with an optical cable.
- Up to 2 SFP+ Modules can be installed.
- Twinax cable can be installed
N8104-186
25GbE
Dual Port 25GBASE SFP28 Adapter
Cavium QL41401, PCIe3.0(x8)
NOTE:
- N8104-190 SFP+ Module is required to connect with an optical cable.
- Up to 2 SFP+ Modules can be installed.
N8104-187
SFP Module
10GbE
SFP+ Module (10G-SR)
1 x SFP+ Module
N8104-189
25GbE
SFP28 Module (25G-SR)
1x SFP28 Module SFP28 can be connected to 25G BASE adapter
NOTE:
- It is not factory installation option.
N8104-190
QSFP28 Module (100G-SR4)
1 x QSFP28 Module QSFP28 can be connected to 25G BASE adapter
N8104-191
NOTE:
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 29
The NIC cards must be installed under the maximum configuration limits for networking when running with VMware systems. For
more detail, see the Networking Maximum in the Configuration Maximums document for VMware.
- For VMware ESXi 6.0: https://www.vmware.com/pdf/vsphere6/r60/vsphere-60-configuration-maximums.pdf
- For VMware ESXi 6.5: https://www.vmware.com/pdf/vsphere6/r65/vsphere-65-configuration-maximums.pdf
NIC Teaming feature - NIC Teaming and bonding features
The Express5800 server supports NIC teaming which is the ability to configure multiple NICs to a virtual single network interface for dual path and load balancing to fault tolerance and load balancing Network Load Balancing.
See the table below for supported network interfaces and OS combinations.
Network Interface
Team
Operating Systems
1GbE NIC
On-board LAN Interface N8104-171/-178/-179
Up to four ports per one team
Windows Server 2012 R2 Windows Server 2016 Red Hat Enterprise Linux 7.3 VMware ESXi 6.0 Update3 VMware ESXi 6.5 Update1
1GbE NIC
N8104-172/-180/-181
Up to four ports per one team
Windows Server 2016 Red Hat Enterprise Linux 7.3 VMware ESXi 6.0 Update3 VMware ESXi 6.5 Update1
10GbE NIC
N8104-173/-182
Up to four ports per one team
Windows Server 2012 R2 Windows Server 2016 Red Hat Enterprise Linux 7.3 VMware ESXi 6.0 Update3 VMware ESXi 6.5 Update1
10GbE NIC
N8104-175/-184
Up to four ports per one team
Windows Server 2012 R2 Windows Server 2016 Red Hat Enterprise Linux 7.3 VMware ESXi 6.0 Update3 VMware ESXi 6.5 Update1
10GbE NIC
N8104-183
Up to four ports per one team
Windows Server 2012 R2 Windows Server 2016 Red Hat Enterprise Linux 7.3 VMware ESXi 6.0 Update3 VMware ESXi 6.5 Update1
10GbE NIC
N8104-185
Up to four ports per one team
Windows Server 2012 R2 Windows Server 2016 Red Hat Enterprise Linux 7.3 VMware ESXi 6.0 Update3 VMware ESXi 6.5 Update1
10GbE NIC
N8104-176/-186
Up to four ports per one team
Windows Server 2012 R2 Windows Server 2016 Red Hat Enterprise Linux 7.3 VMware ESXi 6.0 Update3 VMware ESXi 6.5 Update1
25GbE NIC
N8104-177/-187
Up to four ports per one team
Windows Server 2012 R2 Windows Server 2016 Red Hat Enterprise Linux 7.3
NOTE:
The Bonding function of 10GBASE is available for mode 1 (active-backup) and mode 4 (802.3 ad). Mixing 1000 BASE teaming, 10 GBASE teaming, and 25 GBASE teaming in one system is supported. For Windows Server 2012
R2, Windows Server 2016, Red Hat Enterprise Linux, up to 5 teams per system can be installed
External Storage Controller
External RAID Controller
Category
Product Name / Description
Part Number
Controller
RAID Controller (4GB, RAID0/1/5/6)
RAID0/1/5/6/10/50/60, 4GB, 8 External port PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-196
Battery Backup
Battery Backup Unit
Lithium-ion Battery for RAID controller.
N8103-198
NOTE:
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 30
Only one SAS JBOD Enclosure can be connected to one RAID controller. 4Kn sector drives are not supported with the RAID controller. One battery backup unit must be installed per system. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.
It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard
drives failure.
Fibre Channel / SAS Controller
It is connected to tape device, device expansion unit and iStorage. The controller varies by different device connected
Category
Product Name / Description
Part Number
Fibre Channel
Fibre Channel Controller (1ch)
Cavium QLogic, QLE2690 16Gb/s, Optical, PCIe 3.0 x8
NOTE:
- The controller is qualified with NEC Storage M series, OS support
WS2012R2 and WS2016
- The controller is qualified with NEC Storage T series, OS support
WS2012R2, WS2016 and RHEL7.3
N8190-165
Fibre Channel Controller (2ch)
Cavium QLogic, QLE2692 16Gb/s, Optical, PCIe 3.0 x8
NOTE:
- The controller is qualified with NEC Storage M series, OS support
WS2012R2 and WS2016.
- The controller is qualified with NEC Storage T series, OS support
WS2012R2, WS2016 and RHEL7.3
N8190-166
Fibre Channel Controller (1ch)
Broadcom, LPe31000 16Gb/s, Optical, PCIe 3.0 x8
NOTE:
- The controller is qualified with NEC Storage M series, OS support
WS2012R2 and WS2016.
- The controller is not qualified with NEC Storage T series
N8190-163
Fibre Channel Controller (2ch)
Broadcom, LPe31002 16Gb/s, Optical, PCIe 3.0 x8
NOTE:
- The controller is qualified with NEC Storage M series.
- The controller is not qualified with NEC Storage T series
N8190-164
Fibre Channel Controller (1ch)
Broadcom, LPe32000 32Gb/s, Optical, PCIe 3.0 x8
NOTE:
- The controller is qualified with NEC Storage M series.
- The controller is not qualified with NEC Storage T series
N8190-171
Fibre Channel Controller (2ch)
Broadcom, LPe32002 32Gb/s, Optical, PCIe 3.0 x8
NOTE:
- The controller is qualified with NEC Storage M series
- The controller is not qualified with NEC Storage T series
N8190-172
SAS
SAS Controller
12Gb/s SAS, ext. 8(SFF-8644 x2), PCIe 3.0 x8
NOTE:
- Support tape connection via Device Expansion Unit only
N8103-197
SAS Controller
LSI SAS9300-8e Host Bus Adapter 12Gb/s SAS, ext. 8(SFF-8644 x2), PCIe 3.0(x8)
NOTE:
- Support for connection to NEC Storage T series only.
- The controller is not qualified with NEC Storage the Storage M series or
Tape connection via Device Expansion Unit.
N8103-184
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 31
- Please download the driver kit from Express5800 websiteweb site
- This controller must be installed after shipment.
NOTE:
Please refer to NEC Storage website for supported OS and device For FC-SAN boot, please refer to “FC SAN Boot Configuration Guide” For the cluster configuration, please refer to the ExpressCluster website Fibre Channel (FC) link speed varies by cable type and length
Serial Port Adapter
Product Name / Description
Part Number
Additional Serial Port Kit
Serial port Connector
N8117-09
NOTE:
Up to one serial port adapter can be installed. If you need to install N8154-99 3.5-inch Rear HDD Cage or 3rd Riser Card, an additional serial port kit is not available.
ExpEther Board
It is connected to ExpEther I/O Expasion Unit(40G)
Product Name / Description
Part Number
ExpEther Board
PCIe 3.0(x8), 2x40G QSFP+ board
N8117-09
NOTE:
Up to two ExpEther Board can be installed. QSFP+ module is required. It is supported to directly connect to ExpEther I/O Expansion Unit. Please contact your sales representative for further information.
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 32
8 Other Add-in Components
Power Supply
Category
Product Name / Description
Part Number
1 PSU Required
Up to 2 PSU
500W Hot Plug Power Supply
1 x 500 Watt 80 PLUS® Platinum
N8181-159
800W Platinum Hot Plug Power Supply
1 x 800 Watt 80 PLUS® Platinum
N8181-160
800W Titanium Hot Plug Power Supply
1 x 800 Watt 80 PLUS® Titanium
NOTE:
- Support 200 VAC inlet only
N8181-161
1600W Hot Plug Power Supply
1 x 1600 Watt 80 PLUS® Platinum
NOTE:
- Support 200 VAC inlet only
N8181-162
800W -48VDC Hot Plug Power Supply
1 x 800 Watt 80 PLUS® Platinum
NOTE:
- Support -48 VDC inlet only
- This is make-to-order product.
N8181-163
NOTE:
Minimum one power supply kit must be installed. The power units must be the same to configure redundancy.
Available Power Supplies
See the table below for available power supplies based on the number of drives, the number and type of processors, and the type and number of DIMMs.
24x2.5-inch Drive Model and 12x3.5-inch Drive Model
Number of Processors
Type of Processor
Type of DIMMs
Number of
DIMMs
Available Power Supply
1CPU
Processor with 150 Watt or less
RDIMM
-
800W, 1600W
64GB LRDIMM
-
800W, 1600W
128GB LRDIMM
-
1600W
Processor with 160 Watt or more
- - 1600W
2CPU
Processor with 85 Watt
RDIMM
Up to six
800W, 1600W
Seven or more
1600W
LRDIMM
-
1600W
Processor with 105 Watt or more
- - 1600W
128GB LRDIMM requires 1600W power supply.
8x2.5-inch Drive Model (without Optional Drive Cage) and 8x3.5-inch Drive Model (without Optional Drive Cage)
Number of Processors
Type of Processor
Type of DIMMs
Number of
DIMMs
Number of PCI
Cards
Available Power
Supply
1CPU
Processor with 150 Watt or
less
RDIMM
Up to six
-
500W, 800W, 1600W
Seven or more
-
800W, 1600W 64GB LRDIMM
- - 800W, 1600W
128GB LRDIMM
- - 1600W
Processor with 165 Watt or more
RDIMM
- - 800W, 1600W 64GB LRDIMM
- - 800W, 1600W
128GB LRDIMM
- - 1600W
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 33
2CPU
Processor with 115 Watt or
less
RDIMM
- - 800W, 1600W
64GB LRDIMM
Up to 14
-
800W, 1600W
15 or more
-
1600W
128GB LRDIMM
- - 1600W
Processor with 125 Watt and 130 Watt
RDIMM
Up to 16
-
800W, 1600W
17 or more
-
1600W
64GB LRDIMM
Up to 12
Up to 6
800W, 1600W
7 or more
1600W
13 or more
-
1600W
128GB LRDIMM
- - 1600W
Processor with 140 Watt and 150 Watt
RDIMM Up to 12 Up to 4
800W, 1600W
5 or more
1600W
13 or more
-
1600W
64GB LRDIMM
Up to 8
Up to 4
800W, 1600W
5 or more
1600W
9 or more
-
1600W
128GB LRDIMM
- - 1600W
Processor with 165 Watt or more
- -
1600W
NOTE:
128GB LRDIMM requires 1600W power supply. Number of PCI Cards do NOT include a dedicated RAID card or a dedicated LOM controller.
8x2.5-inch Drive Model (with Optional Drive Cage) and 8x3.5-inch Drive Model (with Optional Drive Cage)
Number of Processors
Type of Processor
Type of DIMMs
Number of
DIMMs
Number of PCI Cards
Available Power
Supply
1CPU
- - - - 800W, 1600W
2CPU
Processor with 85 Watt
RDIMM
Up to 12
-
800W, 1600W
13 or more
-
1600W
LRDIMM
- - 1600W
Processor with 105 Watt
RDIMM
Up to 6
Up to 6
800W, 1600W
7 or more
1600W
7 or more
-
1600W
LRDIMM
- - 1600W
Processor with 115 Watt or
more
- - -
1600W
NOTE:
128GB LRDIMM requires 1600W power supply. Number of PCI Cards do NOT include a dedicated RAID card or a dedicated LOM controller.
8x2.5-inch Drive Model and 8x3.5-inch Drive Model with GPU installation
Number of Processors
Type of Processor
Type of DIMMs
Number of
DIMMs
Number of PCI Cards
Available Power
Supply
1CPU
- - - - 800W, 1600W
2CPU
Processor with 115 Watt or
less
RDIMM
Up to 12
-
800W, 1600W
13 or more
-
1600W
64GB LRDIMM
Up to 6
-
800W, 1600W
7 or more
-
1600W
128GB LRDIMM
- - 1600W
Processor with 125 Watt and
130W
RDIMM
Up to 6
Up to 6
800W, 1600W 7 or more
1600W
7 or more
-
1600W
LRDIMM
- - 1600W
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 34
Processor with 140 Watt and
150 Watts
RDIMM
Up to 6
Up to two
800W, 1600W Three or more
1600W
7 or more
-
1600W
LRDIMM
- - 1600W
Processor with 165 Watt or
more
- - -
1600W
NOTE:
128GB LRDIMM requires 1600W power supply. Number of PCI Cards do NOT include a dedicated RAID card or a dedicated LOM controller.
Guideline of Maximum Power Consumption
See the following table for the guideline of the maximum power consumption based on the TDP and Input voltage. The actual maximum power consumption varies depend on the type of processor while the TDP of processor is the same.
200VAC Input
CPU TDP
8 x 2.5-inch
24 x 2.5-inch
8 x 3.5-inch
12 x 3.5-inch
85 Watt
991W / 992VA
1036W / 1038VA
983W / 984VA
1013W / 1015VA
105 Watt
1048W / 1049VA
1093W / 1094VA
1039W / 1041VA
1070W / 1071VA
115 Watt
1045W / 1047VA
1100W / 1101VA
1046W / 1047VA
1077W / 1078VA
125 Watt
1094W / 1097VA
1150W / 1152VA
1096W / 1097VA
1127W / 1128VA
130 Watt
1086W / 1088VA
1141W / 1142VA
1087W / 1088VA
1118W / 1119VA
140 Watt
1134W / 1135VA
1189W / 1191VA
1135W / 1136VA
1166W / 1167VA
150 Watt
1153W / 1154VA
1208W / 1209VA
1153W / 1155VA
1184W / 1186VA
165 Watt
1201W / 1202VA
1254W / 1255VA
1152W / 1154VA
1183W / 1184VA
200 Watt
1270W / 1271VA
1326W / 1329VA
1217W / 1217A
1244W / 1247VA
205 Watt
1270W / 1271VA
1326W / 1329VA
1217W / 1217A
1244W / 1247VA
NOTE:
This table shows maximum power consumption with 64GB LRDIMM.
High Performance CPU Heatsink
Product Name / Description
Part Number
High Performance CPU Heatsink Kit
Including two high performance CPU heat sink
N8101-1286
NOTE:
The kit is required if you need to replace the standard CPU Heatsink.
Type of CPU Heatsink
The Heatsink attached varies depending on the processor type.
CPU
Type of CPU Heatsink
130W or higher TDP CPU, Intel® Xeon® Processor Platinum 8156, Gold 6128, and Gold 5122
High Performance CPU Heatsink
Others
Standard CPU Heatsink
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 35
Fan Kit
Product Name / Description
Part Number
Standard Fan Kit
4x Hot-plug redundant cooling fans
(Standard)
High Performance Fan Kit
6x Hot-plug redundant cooling fans
N8181-158
NOTE:
High Performance Fan kit is standard on 24x2.5-inch Drive Model and 12x3.5-inch Drive Model High Performance Fan kit is required when the following options are installed on 8x2.5-inch Drive Model and 8x3.5-inch Drive
Model:
- N8154-100 4x3.5-inch Hot Plug Drive Cage Kit(SAS/SATA, Mid)
- N8154-95 2x2.5-inch Hot Plug Drive Cage Kit(SAS/SATA/PCIe SSD)
- N8154-98 2x2.5-inch Hot Plug Drive Cage Kit(SAS/SATA, Rear)
- N8154-99 3x3.5-inch Hot Plug Drive Cage Kit(SAS/SATA, Rear)
- Graphics Card
The cable management arm is required if you want to replace a fan unit while the system is running
Front Panel Kit
9 Product Name / Description
Part Number
Status LED
LED indicator for power, system status and aggregate NIC activity
(Standard)
Status LED Panel Kit
Standard LED indicator plus LED indicator for CPU, Memory, Fan, Power supply, PCI Riser, individual NIC activity For 8x 2.5-inch Drive Model and 24x 2.5-inch Drive Model
N8117-06
NOTE: You can monitor the status of each part from BMC management console or NEC ESMPRO. Ordering the Status LED Panel
Kit, you can check the detailed status of devices directly.
Trusted Platform Module Kit
Product Name / Description
Part Number
Trusted Platform Module Kit
TPM 2.0 module
N8115-35
NOTE:
The kit is not available in China. The kit is not removable after attachment. The kit supports only with Windows operating system configured with UEFI boot mode. "Chipset-TPM" in BIOS setup menu must be activated prior to use of this product. To use Windows BitLocker drive encryption, be sure to keep the "recovery password" of BitLocker function. The recovery password
is required to restore data for hardware replacement during a system error.
USB Memory Kit
Product Name / Description
Part Number
8GB USB Memory
Support boot VMware ESXi from USB memory
N8106-017
Dual 8GB microSD Kit(USB)
Including 2x 8GB microSD, USB dual microSD memory card reader, RAID1 Support
N8106-016
NOTE:
The USB Memory Kit is installed in the system when you order it with the base model. The kit does not include VMware ESXi installation media and license.
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 36
The USB Memory Kit cannot be installed if M.2 SATA Solid State Drives are installed. To use VMware vSAN, combination of vSAN certified hardware is required. If you are using VMware vSAN and cannot boot from USB Memory Kit, please order M.2 SATA SSD.
Power Cable for GPU
Product Name / Description
Part Number
Graphics Card Power Cable (8Pin. Type A)
Power cable for video card (PCIe 8Pin)
K410-386(00)
Graphics Card Power Cable (8Pin. Type B)
Power cable for video card (CPU 8Pin)
K410-387(00)
Graphics Card Power Cable (8+6Pin)
Power cable for video card (8Pin + 6Pin)
K410-388(00)
Graphics Card Power Cable (6+6Pin)
Power cable for video card (6Pin + 6Pin)
K410-391(00)
NOTE:
To install GPU cards, the riser card with a power connector for GPU, High Performance CPU Heatsink, and High Performance Fan
kit must be installed. Refer to PCI Riser Card /PCI Card, High performance CPU heatsink, and Fans in detail
Cable varies depending on the GPU card installed. Please check the specifications of the GPU card and select the cable. For default factory configuration
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 37
10 Factory Server Setting Service
Memory RAS Settings
If you need to change the BIOS settings for the memory RAS feature at the factory, select the appropriate configuration service.
Product Name / Description
Part Number
Memory Mirroring Mode Configuration Service
Setup option to change the Memory RAS of BIOS menu to Memory Mirroring Mode
NESV16-013
Memory Sparing Mode Configuration Service
Setup option to change the Memory RAS of BIOS menu to Memory Sparing Mode
NESV16-014
NOTE:
It is an option only for factory setup Single Rank Memory (N8102-708/-709) does not support Memory Mirroring Mode Configuration Service (NESV16-013)
11 Add-on Components
17-inch LCD Console Drawer
Category
Product Name / Description
Part Number
Drawer w/ KVM
Drawer
17-inch LCD Console Drawer (8port)
17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port KVM switch, 1U height
N8143-106F
Cable
Switch Unit Connection Cable Set (USB, 1.8m)
1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A
K410-118(1A)
Switch Unit Connection Cable Set (USB, 3m)
3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A
K410-118(03)
Switch Unit Connection Cable Set (USB, 5m)
5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A
K410-118(05)
Drawer w/o KVM
Drawer
17inch LCD Console Unit 1U
17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height, 4-pin USB B to 4-pin USB A cable 2 m, PS/2 Y-splitter cable 2m, 15-pin mini D-sub VGA cable 2 m
N8143-105F
17inch LCD Console Drawer (1port)
17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad with 3-button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8 m, Two PS/2 cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m
N8143-108F
Keypad
Keyboard Unit (JP)
JP 108-keys Keyboard with 10-key for N8143-108F 17inch LCD Console Drawer (1port)
N8143-109
Keyboard Unit (UK)
UK 104-keys Keyboard with 10-key, for N8143-108F 17inch LCD Console Drawer (1port)
N8143-111
NOTE:
Keyboard of N8143-105F/-106F does not have 10-key. Order Switch Unit Connection Cable Set as same number of sets as servers to be connected to. (max 8 servers)
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 38
KVM Switch
Category
Product Name / Description
Part Number
KVM Switch
Server Switch Unit (8 server)
1U USB 8 port KVM switch
N8191-14F
Cable
KVM
Switch Unit Connection Cable Set (USB, 1.8m)
1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A
K410-118(1A)
Switch Unit Connection Cable Set (USB, 3m)
3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A
K410-118(03)
Switch Unit Connection Cable Set (USB, 5m)
5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A
K410-118(05)
Cascading
Switch Unit Connection Cable 1.8 m
1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2
K410-119(1A)
NOTE:
Order Switch Unit Connection Cable Set as same sets as servers to be connected to. (N8191-14F max 8 servers)
Server Management License
Choose the following license kit to use additional remote and system management future.
Product Name / Description
Part Number
License for Remote Management (Advanced)
License per server Remote console:
- Integrated Remote Console (IRC) with full functionality Remote media:
- Virtual media access via Integrated Remote Console (IRC)
- Scripted virtual media access System management:
- Global team collaboration for up to six consoles
- Integrated Remote Console (IRC) recording and playback
N8115-33
License for Remote Management (Scale-Out)
License per server Remote console:
- Text-based remote console via SSH
- Integrated Remote Console (IRC) under Pre-OS System management:
- Email alert
- Remote Syslog feature
- Virtual Serial Port recording and playback
N8115-34
NOTE:
Remote management features are not available for virtual machines.
Dust Proof Filter Kit
Product Name / Description
Part Number
Dustproof Filter Kit
It is used for 2U Rack model. Including filter attachment kit and 10 set of dust proof filter When attached to standard bezel can support dust proof function. Suggested replacement: Every 3 months (But depending on environment).
N8147-33
NOTE:
The dustproof filter kit is make-to-order products. Please consult your sales representative in regard to production lead time.
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 39
Slide Rail Kit
Rail
Product Name / Description
Part Number
1 Rail kit Required
Tool-free Slide Rail Kit for 2U-2.5inch Server
N8143-133
Tool-free Slide Rail Kit for 2U-3.5inch Server
N8143-134
Slide Rail Kit for 2U-2.5inch Server
NOTE:
Inner rails are not necessary.
N8143-129
Slide Rail Kit for 2U-3.5inch Server
NOTE:
Inner rails are not necessary.
N8143-130
NOTE:
The slide rail kit must be ordered with a base model.
Cable Management Arm
Product Name / Description
Part Number
Cable Management Arm for 2U Server
Cable Arm for Tool-free Slide Rail Kit
N8143-126
Cable Management Arm for 2U Server
Cable Arm for Slide Rail Kit
N8143-124
NOTE:
The cable management arm install in the rear of system to manage cables. The cable management arm must be ordered with a base model. The cable management arm is required if you want to replace a fan unit while the system is running.
Starter Pack DVD
The starter pack DVD includes the software and driver qualified by NEC. In order to obtain technical support from NEC, please be sure to install the software and drivers provided with the starter pack. The latest DVD image can be downloaded for free from NEC website during the warranty or maintenance contract period.
Product Name / Description
Part Number
Express5800/R120h-1M, R120h-2M Starter Pack
UL9020-B108
NOTE:
By applying Starter Pack, Driver software qualified by NEC can be installed. To use servers, UL9020-B108 Starter Pack or Starter
Pack downloaded from Web site must be installed.
Starter Pack may be updated without notice. The latest version of Start Pack is available in Web site. Starter Pack can be
downloaded within Warranty term.
User Guide of this product is supplied as PDF file in NEC Web site.
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 40
References
External Views
Front and Rear Views
Front View for 8x 2.5-inch Drive Model
Legend
A.
2.5-inch Drive Bays
F.
UID button/LED
B.
Drives or optical/video /USB (optional)
G.
iLO Service Connector
C.
Power On/standby button/LED
H.
Pull-out Tab
D.
Health LED
I.
USB 3.0 Connector
E.
Network Link/Activity LED
Front View for 24x 2.5-inch Drive Model
Legend
A.
2.5-inch Drive Bays
E.
UID button/LED
B.
Power On/standby button/LED
F.
iLO Service Connector
C.
Health LED
G.
Pull-out Tab
D.
Network Link/Activity LED
H.
USB 3.0 Connector
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 41
Front View for 8x 3.5-inch Drive Model
Legend
A.
3.5-inch Drive Bays
G.
UID button LED
B.
2.5-inch Drive Cage Bay
H.
Health LED
C.
Optical Drive Bay
I.
Network Link/Activity LED
D.
Pull-out Tab
J.
Power On/standby button/LED
E.
USB 3.0 Connector
K.
DisplayPort Connector
F.
iLO Service Connector
Front View for 12x 3.5-inch Drive Model
Legend
A.
3.5-inch Drive Bays
D.
Health LED
B.
Power On/standby button/LED
E.
UID LED Button
C.
Network Link/Activity LED
Rear View
Legend
A.
PCI Slots (Standard)
G.
VGA Connector
B.
PCI Slots (option)
H.
NIC Connectors 1-4 (1Gb)
C.
Power Supply
I.
Management Port
D.
AC Inlet
J.
USB 3.0 Connectors
E.
AC Power LED
K.
Rear UID LED
F.
Power Supply (optional)
L.
Flexible LOM (optional)
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 42
Dimensions (mm)
8x and 24x 2.5-inch Drive Model
8x and 12x 3.5-inch Drive Model
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 43
General Supplementary Matters
HDD
Capacity of Hard disk drive is displayed in decimal not binary. 1GB1000^3B1TB=1000^4B.
PCI expansion slot
Transfer speed of PCI Express
PCI Express (PCIe): 2.5Gb/s (simplex) per lane PCI Express 2.0 (PCIe 2.0): 5Gb/s (simplex) per lane PCI Express 3.0 (PCIe 3.0): 8Gb/s (simplex) per lane
Time display
A system clock is affected by temperature conditions in storage. If high accuracy of the system clock is required, use of
NPT servers is recommended.
Memory Supplementary matters
Installation rule
The number of memory which can be installed varies depending on number of installed CPUs. This installation rule defined to maximize performance efficiently in multiple cores and tasks operation. Registered DIMM (RDIMM), Load Reduced DIMM (LRDIMM) can be installed up to 12 per 1CPU. Mixing of RDIMM and LRDIMM is not allowed to be installed.
When install DIMMs, higher capacity memory must be installed preferentially, if ignored this rule, it may cause failures of DIMMs. This rule applies in factory installation.
For dual CPU system, install DIMM to CPU1 firstly and then to CPU2 alternately. Memory population varies with number of installed DIMMs. In installation of 5, 7, 9 or 11 DIMMs per CPU, optimal performance might NOT be obtained. Other memory populations are recommended.
Single CPU system
Dual CPU system
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 44
1-3x DIMM(s) 4x DIMMs
5-7x DIMMs 8x DIMMs
9x DIMMs 10x DIMMs
11-12x DIMMs
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 45
Internal drive supplementary matters
Conditions of internal drives in default factory configuration
In default factory configuration, there are some conditions of drive types and RAID levels can be installed
as below.
Common
All drives in default factory configuration should be of the same type, sector and rotation speed. For the shipment with RAID array, select the drives in the same capacity as many as needed.
RAID controller configuration
RAID level 0, 1, 5, 6, 10 can be installed for default factory configuration shipment. Selectable RAID levels are depending on the
RAID controller.
Capacity of Logical drive can be within 2TB with legacy boot mode, capacity of logical drive can be within the total capacity of
logical disks with UEFI boot mode.
As factory shipment, Initial cache policy of RAID controllers is Write Through for N8103-189, Write back for N8103-190/191.
RAID configuration for shipment
RAID configuration for shipment
Number of Drives
Number of Drives in RAID levels Non RAID
110
Non
Embedded RAID(On-board RAID) configuration (RAID 0/1/10)
1
RAID0 (Single drive)
2
RAID1
3
2 in RAID11 for hot spare
4/6/8
4/6/8 in RAID10
5/7 9 (3.5inch model only)
4/6/8 in RAID10, 1 for a hot spare
10 (3.5inch model only)
8 in RAID10, 2 in RAID1
RAID controller configuration(RAID 0/1/10)
1
RAID0(Single drive)
2
RAID1
3
2 in RAID1, 1 for a hot spare
4/6/8
4/6/8 in RAID10
5/7/9
4/6/8 in RAID10, 1 for a hot spare
10
8 in RAID10, 2 in RAID1
11
8 in RAID10, 2 in RAID1, 1 for a hot spare
12/14/16
8 in RAID10, 4/6/8 in RAID10
13/15/17
8 in RAID10, 4/6/8 in RAID10, 1 for a hot spare
18
2x 8 in RAID10, 2 in RAID1
19
2x 8 in RAID10, 2 in RAID1, 1 for a hot spare
20/22/24
2x 8 in RAID10, 4/6/8 in RAID10
21/23/25
2x 8 in RAID10, 4/6/8 in RAID10, 1 for a hot spare
26
3x 8 in RAID10, 2 in RAID1
RAID controller configuration (RAID 0/1/5/6/10)
1
RAID0(Single drive)
2
RAID1
3-8
RAID5
9
8 in RAID 5, 1 in RAID0 (Single drive)
10
8 in RAID 5, 2 in RAID 1
11-16
8 in RAID 5, 3-8 in RAID5
17
2x 8 in RAID 5, 1 in RAID0 (Single drive)
18
2x 8 in RAID 5, 2 in RAID 1
19-24
2x 8 in RAID 5, 3-8 in RAID5
25
3x 8 in RAID 5, 1 in RAID0 (Single drive)
26
3x 8 in RAID 5, 2 in RAID 1
27-30
3x 8 in RAID 5, 3-8 in RAID5
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 46
Conditions for mixing of Internal Drives
Mixing of different type of SSD, HDD and mixing of HDD and SSD are not allowed to be installed in default factory configuration. RAID controller is required for mixing of Internal Drives Mixed Internal Drives cannot be installed in the same RAID array. When using hot spare disk for different RAID arrays which consist of various type of drives, assign “Dedicated Hot Spare” to each
RAID arrays with the same type of drive, to prevent from mixing different type of drives in a RAID array. “Global Hot Spare” cannot be used.
Mixing of different type of drives
Two types of drive can be installed in standard drive cage (8slots) and optional drive cage (8slots), in total, up to four types of drive using both cages. There is nine “type”, such as SAS HDD 10,000rpm(512n), SAS HDD 10,000rpm(512e), SAS HDD 15,000rpm(512n), SAS HDD 7,200rpm(512e), SATA HDD 7,200rpm(512n), SATA HDD 7,200rpm(512e), SATA SSD(ME/VE/RI).
See some examples as below.
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 47
Server Management
The integrated server management controller provides superior remote control and system management features listed in the table below.
Standard
Remote
Management
License
(Scale-out)
Remote
Management
License
(Advanced)
Authentication with Active Directory and LDAP
-
-

Two-factor and Kerberos authentication
-
-

Virtual media access via Integrated Remote Console (IRC)
-
-

Scripted virtual media access
-
-

Integrated Remote Console (IRC)
Pre-OS Only
Pre-OS Only

Global team collaboration for up to six consoles
-
-

Integrated Remote Console (IRC) recording and playback
-
-

Virtual Serial Port recording and playback
-
Text-based remote console via SSH
-


Email alert
-


Remote Syslog feature


Advanced power management (power history graph, power capping)
-


BMC federation management
-
BMC detection for BMC federation
Remote serial console (Virtual Serial Port)

Server Health Summary
Restart BMC form web-based management console
Redfish™API

Agentless Management

Server Health monitoring

Web-based GUI
Virtual power buttons
SSH / SMASH Command-Line Protocol (including serial console redirection)
IPMI / DCMI (including serial console redirection)
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 48
OS Support Matrix for PCI Cards and Embedded Controllers
Part number
Product Name
WS 20
16
WS 2012 R2 RHEL
7
ESXi
6.5
ESXi
6.0
-
Embedded SATA non-RAID Controller


   - Embedded SATA RAID Controller


- - -
N8103-189
RAID Controller (RAID 0/1)

N8103-190
RAID Controller (2GB, RAID 0/1/5/6)

N8103-191
RAID Controller (4GB, RAID 0/1/5/6)

N8103-195
RAID Controller (4GB, RAID 0/1)

N8103-201
RAID Controller (2GB, RAID 0/1/5/6)

N8103-196
RAID Controller (4GB, RAID 0/1/5/6)

N8103-197
SAS Controller

-
N8104-171
Quad Port 1000BASE-T LOM Card

N8104-172
Quad Port 1000BASE-T LOM Card
- 
N8104-173
Quad Port 10GBASE-T LOM Card

N8104-175
Dual Port 10GBASE-T LOM Card

N8104-176
Quad Port 10BASE SFP+ LOM Card

N8104-178
Dual Port 1000BASE-T Adapter

N8104-179
Quad Port 1000BASE-T Adapter

N8104-180
Dual Port 1000BASE-T Adapter
- 
N8104-181
Quad Port 1000BASE-T Adapter
- 
N8104-182
Dual Port 10GBASE-T Adapter

N8104-183
Dual Port 10GBASE-T Adapter

N8104-184
Dual Port 10GBASE-T Adapter

N8104-185
Dual 10GBASE SFP+ Adapter

N8104-186
Dual 10GBASE SFP+ Adapter

N8190-165
Fibre Channel Controller (1ch)


-
-
N8190-166
Fibre Channel Controller (2ch)


-
-
N8190-171
Fibre Channel Controller (1ch)


-
-
N8190-172
Fibre Channel Controller (2ch)


-
-
N8190-163
Fibre Channel Controller (1ch)

N8190-164
Fibre Channel Controller (2ch)

SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 49
Supported PCI Cards and Installable Slots
Part Number
Product Name
RAID
FLOM
SLOT1
SLOT2
SLOT3
SLOT4
SLOT5
SLOT6
SLOT7
SLOT8
N8103-189
RAID Controller (RAID 0/1)
1 - - - - - - - - - N8103-190
RAID Controller (2GB, RAID 0/1/5/6)
1 - - - - - - - -
-
N8103-191
RAID Controller (4GB, RAID 0/1/5/6)
1 - - - - - - - -
-
N8103-195
RAID Controller (4GB, RAID 0/1/5/6)
- - 1 3 5 2 4 6 7 8 N8103-201
RAID Controller (2GB, RAID 0/1/5/6)
- - 1 3 5 2 4 6 7 8 N8103-196
RAID Controller (4GB, RAID 0/1/5/6)
- - 1 3 5 2 4 6 7 8 N8103-197
SAS Controller
- - 1 3 5 2 4 6 7 8 N8104-171
Quad Port 1000BASE-T LOM Card
- 1 - - - - - - - - N8104-172
Quad Port 1000BASE-T LOM Card
- 1 - - - - - - -
-
N8104-173
Quad Port 10GBASE-T LOM Card
- 1 - - - - - - -
-
N8104-175
Dual Port 10GBASE-T LOM Card
- 1 - - - - - - -
-
N8104-176
Quad Port 10BASE-SFP+ LOM Card
- 1 - - - - - - - - N8104-178
Dual Port 1000BASE-T Adapter
- - 1 3 5 2 4 6 7 8 N8104-179
Quad Port 1000BASE-T Adapter
- - 1 3 5 2 4 6 7
8
N8104-180
Dual Port 1000BASE-T Adapter
- - 1 3 5 2 4 6 7
8
N8104-181
Quad Port 1000BASE-T Adapter
- - 1 3 5 2 4 6 7 8 N8104-182
Dual Port 10GBASE-T Adapter
- - 1 3 5 2 4 6 7 8 N8104-183
Dual Port 10GBASE-T Adapter
- - 1 3 5 2 4 6 7 8 N8104-184
Dual Port 10GBASE-T Adapter
- - 1 3 5 2 4 6 7
8
N8104-185
Dual 10GBASE-SFP+ Adapter
- - 1 3 5 2 4 6 7
8
N8104-186
Dual 10GBASE-SFP+ Adapter
- - 1 3 5 2 4 6 7 8 N8190-165
Fibre Channel Controller (1ch)
- - 1 3 5 2 4 6 7 8 N8190-166
Fibre Channel Controller (2ch)
- - 1 3 5 2 4 6 7 8 N8190-171
Fibre Channel Controller (1ch)
- - 1 3 5 2 4 6 7 8 N8190-172
Fibre Channel Controller (2ch)
- - 1 3 5 2 4 6 7 8 N8190-163
Fibre Channel Controller (1ch)
- - 1 3 5 2 4 6 7
8
N8190-164
Fibre Channel Controller (2ch)
- - 1 3 5 2 4 6 7
8
N8116-51
SAS Expander Card
- - 1 3 5 2 4 6 7
8
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Slot 8
LOM RAID
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 50
Expansion Slots
Slot Name
Standard
Bus Width
Connector Width
Height
Length
Processor
Other Connector
Dedicated Slots
LOM
PCIe 3.0
x8
x8 - -
CPU1
-
RAID
PCIe 3.0
x8
x8 - -
CPU1
-
1st Riser Card (Standard)
Slot 1
PCIe 3.0
x8
x8
Full-height
Full Length
CPU1
2x M.2
Slot 2
PCIe 3.0
x16
x16
Full-height
Full Length
CPU1
Slot 3
PCIe 3.0
x8
x8
Full-height
Up to 1/2 length
CPU1
1st Riser Card (Optional) N8116-66
Slot 1
- - - - -
-
GPU Power
Slot 2
PCIe 3.0
x16
x16
Full-height
Full Length
CPU1
Slot 3
PCIe 3.0
x16
x16
Full-height
Up to 1/2 length
CPU1
1st Riser Card (Optional) N8116-64
Slot 1
PCIe 3.0
x16
x16
Full-height
Full Length
CPU1
-
Slot 2
PCIe 3.0
x16
x16
Full-height
Full Length
CPU1
Slot 3
- - - - -
-
Drive Cage Kit (Optional) N8154-98
Slot 1
- - - - -
- - Slot 2
- - - - - - Slot 3
PCIe 3.0
x16
x16
Full-height
Up to 1/2 length
CPU1
2nd Riser Card (Optional) N8116-62
Slot 4
PCIe 3.0
x8
x8
Full-height
Full Length
CPU2
GPU Power
Slot 5
PCIe 3.0
x16
x16
Full-height
Full Length
CPU2
Slot 6
PCIe 3.0
x8
x8
Full-height
Up to 1/2 length
CPU2
2nd Riser Card (Optional) N8116-67
Slot 4
- - - - -
-
GPU Power
Slot 5
PCIe 3.0
x16
x16
Full-height
Full Length
CPU2
Slot 6
PCIe 3.0
x16
x16
Full-height
Up to 1/2 length
CPU2
2nd Riser Card (Optional) N8116-56
Slot 4
PCIe 3.0
x16
x16
Full-height
Full Length
CPU2
-
Slot 5
PCIe 3.0
x16
x16
Full-height
Full Length
CPU2
Slot 6
- - - - -
-
Drive Cage Kit (Optional) N8154-98
Slot 4
- - - - -
- - Slot 5
- - - - - - Slot 6
PCIe 3.0
x16
x16
Full-height
Up to 1/2 length
CPU2
3rd Riser Card (Optional) N8116-78
Slot 7
PCIe 3.0
x8
x8
Full-height
Full Length
CPU2
­Slot 8
PCIe 3.0
x8
x8
Full-height
Up to 1/2 length
CPU2
3rd Riser Card (Optional) N8116-81
Slot 7
PCIe 3.0
x16
x16
Full-height
Full Length
CPU2
GPU Power Slot 8
- - - - -
-
Supported Tape and Removal Disk Backup Drive List
See the following table for supported tape and removal disk backup drives. An optional tape drive enclosure is needed to connect the backup drives to the server.
Category
Product Name / Description
Part Number
LTO
Internal LTO (SAS)
LTO5, Half height, Native capacity 1.5 TB
N8151-141
Internal LTO (SAS)
LTO6, Half height, Native capacity 2.5 TB
N8151-142
Internal LTO (SAS)
LTO7, Half height, Native capacity 6 TB
N8151-143
RDX
Internal RDX (USB)
N8151-139
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Slot 8
LOM RAID
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 51
Copyright Notice and Liability Disclaimer
The information contained herein is subject to change without notice. Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or
other countries Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other
countries. Linux is a trademark of Linus Torvalds. Red Hat is a registered trademark of Red Hat, Inc. in the U.S. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less.
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120h-2M
NEC Corporation Revision 5.0 – January 2018 52
Revision History
Revision
Date
Description
5.0
January 25, 2018
Discontinued products deleted:
1TB 7.2K Hot Plug 2.5-inch SATA HDD / N8150-544 (Replacement part number to be
released soon.)
4TB 7.2K Hot Plug 3.5-inch SAS HDD / N8150-561 (Replacement part number to be
released soon.)
3TB 7.2K Hot Plug 3.5-inch SATA HDD / N8150-556 (No replacement planed)
Quad Port 25GBASE QSPF28 Adapter / N8104-188
Others:
Correction of errors
4.0
December 22, 2017
New products added:
400GB Hot Plug 2.5-inch SAS SSD / N8150-748
800GB Hot Plug 2.5-inch SAS SSD / N8150-749
400GB Hot Plug 2.5-inch SAS SSD / N8150-750
800GB Hot Plug 2.5-inch SAS SSD / N8150-751
480GB Hot Plug 2.5-inch SAS SSD / N8150-752
960GB Hot Plug 2.5-inch SAS SSD / N8150-753
Dual Port 25GBASE SFP28 Adapter / N8104-187
Dual Port 25GBASE SFP+ LOM Card / N8104-177
SFP28 Module(25G-SR) / N8104-190
SAS Controller / N8103-184
Others:
Updated the table of the Available Power Supplies
SAS Expander supported SATA drives
Information in References is updated
3.0
November 22, 2017
New products added:
Xeon Gold 6144 Processor Kit / N8101-1231, N8101-1232
Xeon Gold 6146 Processor Kit / N8181-1233, N8101-1234
3.84TB Hot Plug 2.5-inch SATA SSD / N8150-747
240GB Hot Plug 2.5-inch SATA SSD / N8150-739
Dual Port 10GBASE-T Adapter / N8104-183
Dual Port 10GBASE-T Adapter / N8104-184
Others:
Added the table of guideline of the maximum power consumption
Added VMware ESXi 6.5 to the list of operating system supported
Updated OS support matrix
2.0
October 19, 2017
New products added:
4TB 7.2K Hot Plug 3.5-inch SAS HDD / N8150-561
8TB 7.2K Hot Plug 3.5-inch SAS HDD / N8150-562
10TB 7.2K Hot Plug 3.5-inch SAS HDD / N8150-563
150GB Non-hot-plug M.2 SATA SSD / N8150-778
Fibre Channel Controller (1ch) / N8190-171
Fibre Channel Controller (2ch) / N8190-172
Discontinued product deleted:
120GB Non-hot plug M.2 SATA SSD / N8150-754
Others:
Updated the OS support matrix
Updated Supported PCI Cards and Installable Slots matrix
Added the table of maximum power consumption
1.1
September 20, 2017
Others:
Added note for the number of SATA ports available on 8x 2.5-inch Drive Model using with embedded SATA controller
Added note when ordering an optical drive with 8x 3.5-inch Drive Model
Added note when ordering M.2 SATA SSD
Updated the table of available power supplies
1.0
August 29, 2017
Initial release