NEC Express5800/R110i-1
System Configuration Guide
Introduction
This document contains product and configuration information that will enable you to configure your system. The guide will
ensure fast and proper configuration of your NEC Express5800 server.
June 6, 2017
Revision 2.0
NEC Corporation

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 2
Contents
TECHNICAL SPECIFICATION ........................................................................................ 3
Specification .......................................................................................................................................... 3
EXTERNAL VIEWS ......................................................................................................... 8
Front and Rear Views ........................................................................................................................... 8
Dimensions (mm) ................................................................................................................................ 10
CONFIGURATION DIAGRAM ....................................................................................... 11
EXPANSION SLOTS ..................................................................................................... 12
SERVER CONFIGURATION ......................................................................................... 13
1 Base Models ........................................................................................................................... 13
2 Processor................................................................................................................................ 13
3 Memory ................................................................................................................................... 14
4 Internal Hard Disk Drives ........................................................................................................ 15
4.1 RAID Configuration .............................................................................................................. 15
4.2 Required Components for RAID Configuration ................................................................... 17
4.3 Supported Drives ................................................................................................................. 21
5 Optical Drive ........................................................................................................................... 25
6 PCI Card ................................................................................................................................. 26
6.1 Network Interface Controller ................................................................................................ 26
6.2 External Storage Controller ................................................................................................. 27
Graphics Accelerator ........................................................................................................... 27
6.4 Serial Port Adapter .............................................................................................................. 28
7 Other Add-in Components ...................................................................................................... 28
7.1 Cooling Fan Kit .................................................................................................................... 28
7.2 Trusted Platform Module Kit ................................................................................................ 28
7.3 Internal Flash Memory ......................................................................................................... 28
7.4 High temperature resistant Kit ............................................................................................. 28
7.5 Flash FDD............................................................................................................................ 29
8 Add-on Components ............................................................................................................... 29
8.1 17-inch LCD Console Drawer .............................................................................................. 29
8.2 KVM Switch ......................................................................................................................... 29
8.3 Server Management License............................................................................................... 30
REFERENCES............................................................................................................... 31
Boot Mode Setting .............................................................................................................................. 31
Server Management ............................................................................................................................ 32
Endurance of SSD ............................................................................................................................... 33
OS Support Matrix for PCI Cards and Embedded Controllers ....................................................... 34
Supported PCI cards and Installable Slots....................................................................................... 35
Secure Boot Mode ............................................................................................................................... 37
Copyright Notice and Liability Disclaimer ........................................................................................ 38
REVISION HISTORY ..................................................................................................... 39

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 3
Technical Specification
Specification
2.5-inch Drive Model
(1/2)
Intel® Pentium®
Processor
G4560
Intel® Xeon®
Processor
E3-1220 v6
Intel® Xeon®
Processor
E3-1225 v6
Intel® Xeon®
Processor
E3-1230 v6
DDR4-2400 ECC Unbuffered DIMM
SATA HDD: 16 TB (8 x 2 TB)
SAS HDD : 14.4 TB (8 x 1.8 TB)
SATA SSD 12.8 TB (8 x 1.6 TB)
SAS SSD 3.2 TB (8 x 400 GB)
SATA : 6 Gb/s (Integrated)
SATA/SAS : 6/12 Gb/s (Optional)
SATA : RAID 0/1/10 (Standard
1
)
SATA/SAS : RAID 0/1/5/6/10/50/60 (Optional)
Total: 3 slots available
1 PCIe 3.0 x16 (x16 connector)
1 PCIe 3.0 x4 (x8 connector)
1 PCIe 3.0 x4 (x8 connector) dedicated RAID slot
Integrated in Server Management Controller (32MB)
1 VGA (15-pin mini D-sub,1 rear)
1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear)
6 USB 3.0 (2 front, 4 rear) (plus 1 internal USB 3.0)
2 1000BASE-T LAN connector (RJ-45, 2 rear)
1 1000BASE-T LAN connector for management (RJ-45, 1 rear)
2 450 Watt 80 PLUS® Gold certified Hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Acoustic Noise
(Sound Pressure
Level) 3
444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U)
Weight (Minimum / Maximum)
10 kg / 17.5 kg, 22.05 lbs. / 38.58 lbs.
Temperature, Relative Humidity (non-condensing)
Operating: 5° to 40° C / 41° to 104° F (Standard)
or 5° to 45° C / 41° to 113° F (Optional), 10 to 85%
Non-Operating: -10° to 55° C / 14° to 131° F, 10 to 85%

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 4
FCC, c-UL, CE, CB, RoHS, WEEE, BSMI, CCC
Operating Systems and Virtualization Software
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
Microsoft® Windows Server® 2012 R2 Standard
Microsoft® Windows Server® 2012 R2 Datacenter
Microsoft® Windows Server® 2016 Standard
Microsoft® Windows Server® 2016 Datacenter
Red Hat Enterprise Linux 7.3 or later
4
VMware ESXi 6.0 Update 3
5
VMware ESXi 6.5
5
1
Embedded SATA RAID controller is supported only on limited operating systems.
2
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
3
Noise emission was measured in accordance with ISO 7779, at 25°C. The actual value may vary by the operating environment.
4
For Linux support, contact your sales representative or visit the NEC website at:
http://www.nec.com/en/global/prod/express/linux/index.html
5
Supported on Xeon processor systems only.
(2/2)
Intel® Xeon®
Processor E3-1240L v5
Intel® Xeon®
Processor
E3-1260L
v5
Intel® Xeon®
Processor E3-1270
v6
DDR4-2400 ECC Unbuffered DIMM
SATA HDD: 16 TB (8 x 2 TB)
SAS HDD : 14.4 TB (8 x 1.8 TB)
SATA SSD 12.8 TB (8 x 1.6 TB)
SAS SSD 3.2 TB (8 x 400 GB)
SATA : 6 Gb/s (Integrated)
SATA/SAS : 6/12 Gb/s (Optional)
SATA : RAID 0/1/10 (Standard
1
)
SATA/SAS : RAID 0/1/5/6/10/50/60 (Optional)
Total: 3 slots available
1 PCIe 3.0 x16 (x16 connector)
1 PCIe 3.0 x4 (x8 connector)
1 PCIe 3.0 x4 (x8 connector) dedicated RAID slot
Integrated in Server Management Controller (32MB)
1 VGA (15-pin mini D-sub,1 rear)
1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear)
6 USB 3.0 (2 front, 4 rear) (plus 1 internal USB 3.0)
2 1000BASE-T LAN connector (RJ-45, 2 rear)
1 1000BASE-T LAN connector for management (RJ-45, 1 rear)
2 450 Watt 80 PLUS® Gold certified Hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 5
Acoustic Noise
(Sound Pressure
Level) 3
444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U)
Weight (Minimum / Maximum)
10 kg / 17.5 kg, 22.05 lbs. / 38.58 lbs.
Temperature, Relative Humidity (non-condensing)
Operating: 5° to 40° C / 41° to 104° F (Standard)
or 5° to 45° C / 41° to 113° F (Optional), 10 to 85%
Non-Operating: -10° to 55° C / 14° to 131° F, 10 to 85%
FCC, c-UL, CE, CB, RoHS, WEEE, BSMI, CCC
Operating Systems and Virtualization Software
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
Microsoft® Windows Server® 2012 R2 Standard
Microsoft® Windows Server® 2012 R2 Datacenter
Microsoft® Windows Server® 2016 Standard
Microsoft® Windows Server® 2016 Datacenter
Red Hat Enterprise Linux 7.3 or later
4
VMware ESXi 6.0 Update 3
5
VMware ESXi 6.5
5
1
Embedded SATA RAID controller is supported only on limited operating systems.
2
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
3
Noise emission was measured in accordance with ISO 7779, at 25°C. The actual value may vary by the operating environment.
4
For Linux support, contact your sales representative or visit the NEC website at:
http://www.nec.com/en/global/prod/express/linux/index.html
3.5-inch Drive Model
(1/2)
Intel® Pentium®
Processor
G4560
Intel® Xeon®
Processor
E3-1220 v6
Intel® Xeon®
Processor
E3-1225 v6
Intel® Xeon®
Processor
E3-1230 v6
DDR4-2400 ECC Unbuffered DIMM
SATA : 6Gb/s (Integrated)
SATA : RAID 0/1/10 (Standard 1 ), RAID 5/6 (Optional)
Total: 3 slots available
1 PCIe 3.0 x16 (x16 connector)
1 PCIe 3.0 x4 (x8 connector)
1 PCIe 3.0 x4 (x8 connector) dedicated RAID slot
Integrated in Server Management Controller (32MB)
1 VGA (15-pin mini D-sub,1 rear)
1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear)
6 USB 3.0 (2 front, 4 rear) (plus 1 internal USB 3.0)

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 6
2 1000BASE-T LAN connector (RJ-45, 2 rear)
1 1000BASE-T LAN connector for management (RJ-45, 1 rear)
1 400 Watt 80 PLUS® Platinum certified non-Hot plug PSU
2 450 Watt 80 PLUS® Gold certified Hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Acoustic Noise
(Sound Pressure
Level) 3
444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U)
Weight (Minimum / Maximum)
10 kg / 17.5 kg, 22.05 lbs. / 38.58 lbs.
Temperature, Relative Humidity (non-condensing)
Operating: 5° to 40° C / 41° to 104° F (Standard)
or 5° to 45° C / 41° to 113° F (Optional), 10 to 85%
Non-Operating: -10° to 55° C / 14° to 131° F, 10 to 85%
FCC, c-UL, CE, CB, RoHS, WEEE, BSMI, CCC
Operating Systems and Virtualization Software
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
Microsoft® Windows Server® 2012 R2 Standard
Microsoft® Windows Server® 2012 R2 Datacenter
Microsoft® Windows Server® 2016 Standard
Microsoft® Windows Server® 2016 Datacenter
Red Hat Enterprise Linux 7.3 or later
4
VMware ESXi 6.0 Update 3
5
VMware ESXi 6.5
5
1
Embedded SATA RAID controller is supported only on limited operating systems.
2
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
3
Noise emission was measured in accordance with ISO 7779, at 25°C. The actual value may vary by the operating environment.
4
For Linux support, contact your sales representative or visit the NEC website at:
http://www.nec.com/en/global/prod/express/linux/index.html
5
Supported on Xeon processor systems only.
(2/2)
Intel® Xeon®
Processor E3-1240L v5
Intel® Xeon®
Processor
E3-1260L
v5
Intel® Xeon®
Processor E3-1270
v6 Clock Speed
DDR4-2400 ECC Unbuffered DIMM
SATA : 6Gb/s (Integrated)
SATA : RAID 0/1/10 (Standard 1 ), RAID 5/6 (Optional)
Total: 3 slots available
1 PCIe 3.0 x16 (x16 connector)
1 PCIe 3.0 x4 (x8 connector)

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 7
1 PCIe 3.0 x4 (x8 connector) dedicated RAID slot
Integrated in Server Management Controller (32MB)
1 VGA (15-pin mini D-sub,1 rear)
1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear)
6 USB 3.0 (2 front, 4 rear) (plus 1 internal USB 3.0)
2 1000BASE-T LAN connector (RJ-45, 2 rear)
1 1000BASE-T LAN connector for management (RJ-45, 1 rear)
1 400 Watt 80 PLUS® Platinum certified non-Hot plug PSU
2 450 Watt 80 PLUS® Gold certified Hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Acoustic Noise
(Sound Pressure
Level) 3
444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U)
Weight (Minimum / Maximum)
10 kg / 17.5 kg, 22.05 lbs. / 38.58 lbs.
Temperature, Relative Humidity (non-condensing)
Operating: 5° to 40° C / 41° to 104° F (Standard)
or 5° to 45° C / 41° to 113° F (Optional), 10 to 85%
Non-Operating: -10° to 55° C / 14° to 131° F, 10 to 85%
FCC, c-UL, CE, CB, RoHS, WEEE, BSMI, CCC
Operating Systems and Virtualization Software
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
Microsoft® Windows Server® 2012 R2 Standard
Microsoft® Windows Server® 2012 R2 Datacenter
Microsoft® Windows Server® 2016 Standard
Microsoft® Windows Server® 2016 Datacenter
Red Hat Enterprise Linux 7.3 or later
4
VMware ESXi 6.0 Update 3
5
VMware ESXi 6.5
5
1
Embedded SATA RAID controller is supported only on limited operating systems.
2
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
3
Noise emission was measured in accordance with ISO 7779, at 25°C. The actual value may vary by the operating environment.
4
For Linux support, contact your sales representative or visit the NEC website at:
http://www.nec.com/en/global/prod/express/linux/index.html

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 8
External Views
Front and Rear Views
Front View for 2.5-inch Drive Model
Front View for 3.5-inch Drive Model
B
A
C
D
E F G H I J K L
M N
B
A
C
D
E F G H I J K L
M N

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 9
Rear View for Non-redundant PSU Configuration
Rear View for Redundant PSU Configuration
D
A
B
H I
K L
E
FC
D
C
J
G

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 10
Dimensions (mm)
Non-Hot plug PSU Configuration
Hot plug PSU Configuration

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 11
Configuration Diagram
2.5-inch Drive Model
Legend: Standard Components Mandatory components
3.5-inch Drive Model (Non-redundant PSU)
Legend: Standard Components Mandatory components

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 12
3.5-inch Drive Model (Redundant PSU)
Legend: Standard Components Mandatory components
Expansion Slots
PCIe 3.0 (x4) x4 lanes, x8 connector, for a dedicated RAID controller
PCIe 3.0 (x16) x16 lanes, x16 connector, Low profile, up to 173 mm length
PCIe 3.0 (x4) x4 lanes, x8 connector, Low profile, up to 173 mm length

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 13
Server Configuration
1 Base Models
Product Name / Description
NEC Express5800/R110i-1
No CPU, no RAM, no 3.5-inch HDD, no Cooling FAN, no ODD
Including:
3.5-inch Drive Cage, 1x 400 Watt non-hot plug power supply, Front bezel
NEC Express5800/R110i-1
No CPU, no RAM, no 3.5-inch HDD, no Cooling FAN, no ODD
Including:
3.5-inch Drive Cage, 2 x 450 Watt hot plug power supply, Front bezel
NEC Express5800/R110i-1
No CPU, no RAM, no 2.5-inch HDD, no Cooling FAN, no ODD
Including:
2.5-inch Drive Cage, 2 x 450 Watt hot plug power supply, Front bezel,
NOTE:
The base model must be ordered with a processor kit, a memory kit, a cooling fan kit, and internal hard drive cable
2 Processor
Available sockets: 1
Product Name / Description
Pentium G4560 Processor Kit
Intel® Pentium ® Processor G4560 (3.50 GHz, 2C/4T, 3 MB)
Xeon E3-1220 v6 Processor Kit
Intel® Xeon ® Processor E3-1220 v6 (3 GHz, 4C/4T, 8 MB)
Xeon E3-1225 v6 Processor Kit
Intel® Xeon ® Processor E3-1225 v6 (3.30 GHz, 4C/4T, 8 MB)
Xeon E3-1230 v6 Processor Kit
Intel® Xeon ® Processor E3-1230 v6 (3.50 GHz, 4C/8T, 8 MB)
Xeon E3-1240L v5 Processor Kit
Intel® Xeon ® Processor E3-1240L v5 (2.10 GHz, 4C/8T, 8 MB)
Xeon E3-1260L v5 Processor Kit
Intel® Xeon ® Processor E3-1260L v5 (2.90 GHz, 4C/8T, 8 MB)
Xeon E3-1270 v6 Processor Kit
Intel® Xeon ® Processor E3-1270 v6 (3.80 GHz, 4C/8T, 8 MB)
NOTE:
The processor kit must be ordered with the base model.
VMware ESXi is not supported on Pentium processor systems.

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 14
3 Memory
Available slots: 4
Product Name / Description
4GB DDR4-2400 UNB Memory Kit
4GB Unbuffered ECC DIMM, DDR4-2400
8GB DDR4-2400 UNB Memory Kit
8GB Unbuffered ECC DIMM, DDR4-2400
16GB DDR4-2400 UNB Memory Kit
16GB Unbuffered ECC DIMM, DDR4-2400
NOTE:
Minimum one memory kit must be installed.
It is recommended to install memory kits in pairs of two identical DIMMs for dual-channel symmetric memory configurations to
increase memory transfer speed.
At least 5 GB of memory is required for VMware ESXi™ 5.5 and VMware ESXi™ 6.0
Maximum Available Memory
See the table below for the maximum memory size that you can actually use on your system.
The maximum available memory is less than the maximum physical memory supported by your system because some chipsets
require PCI resource space of about 750MB. PCI resource requirements vary depending on the type and the number of PCI cards
you are using.
Maximum Memory Size Supported by Operating Systems
Microsoft Windows Server 2012 Standard
Microsoft Windows Server 2012 Datacenter
Microsoft Windows Server 2012 R2 Standard
Microsoft Windows Server 2012 R2 Datacenter
Microsoft Windows Server 2016 Standard
Microsoft Windows Server 2016 Datacenter
64GB
Red Hat Enterprise Linux 7
1
The maximum available memory size of Hyper-V systems are below:
- Windows Server 2012, Windows Server 2012 R2 : 4 TB
- Windows Server 2016 : 24 TB
2
Up to 4 TB of main memory is available to each virtual machine.
3
Up to 6 TB of main memory is available to each virtual machine.

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 15
4 Internal Hard Disk Drives
4.1 RAID Configuration
Refer to the section in accordance with your disk form factor and RAID configuration.
4.1.1 2.5-inch Drive
Supported RAID configuration
Supported
HDD/SSD
RAID and Cache
Windows Server 2012
Windows Server 2012 R2
Windows Server 2016
RAID 0/1 (Embedded SATA RAID)
Red Hat Enterprise Linux 7
VMware ESXi 6.5
NOTE:
Up to four drives can be installed when you choose the Embedded SATA non-RAID controller.
All drives within a RAID array should be of the same type, capacity and rotation speed.
Up to two kinds of drives selected from SAS 10K HDDs (512n), SAS 10K HDDs (512e), SAS 15K HDDs, SATA HDDs SAS
SSDs, SATA SSD (ME), and SATA SSD (VE) can be mixed.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Slot 0
Slot 1

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 16
4.1.2 3.5-inch Drive
Supported RAID configuration
Supported
HDD/SSD
RAID and Cache
Windows Server 2012
Windows Server 2012 R2
Windows Server 2016
RAID 0/1 (Embedded SATA RAID)
Red Hat Enterprise Linux 7
VMware ESXi 6.5
NOTE:
All hard drives within a RAID array should be of the same capacity.
4.1.3 M.2 SATA SSD
The M.2 SATA SSD can be used for boot drive only. See the table below for the system configuration of M.2 SATA SSD and support
for the mixed installation of M.2 SATA SSDs and internal hard drives.
M.2 SATA SSD configuration
Support for the mixed
installation of M.2 SATA
SSD and internal hard
drives.
Red Hat Enterprise Linux 7
VMware ESXi 6.0
VMware ESXi 6.5
Not supported
RAID 0/1/10 1GB Cache
Windows Server 2012
Windows Server 2012 R2
Windows Server 2016
RAID 0/1 (Embedded SATA RAID)
Supported: Optional RAID
controller is required to install
internal hard drives.
Not supported
RAID 0/1/10 1GB Cache
Slot 0 Slot 1 Slot 2 Slot 3

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 17
4.2 Required Components for RAID Configuration
4.2.1 Embedded SATA non-RAID Controller for 2.5-inch Drives
Product Name / Description
Embedded SATA Controller
4 x 6Gb/s SATA
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set
2.5-inch Drive Cage
8 x 2.5-inch Hot-plug hard drive bays
NOTE:
Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller.
4.2.2 Embedded SATA RAID Controller for 2.5-inch Drives
Product Name / Description
Embedded SATA Controller
4x 6Gb/s SATA, RAID 0/1/10 capable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set
2.5-inch Drive Cage
8 x 2.5-inch Hot-plug hard drive bays
NOTE
Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS Support Matrix for PCI
Cards and Embedded Controllers.
All hard drives within a RAID array should be of the same capacity.
4.2.3 RAID 0/1 Controller without Cache for 2.5-inch Drives
Product Name / Description
Storage Controller
Required
RAID Controller (RAID 0/1)
Broadcom MegaRAID SAS 9341-8i
RAID 0/1/10, non-cache, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set, for 5th - 8th hard drives
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
NOTE:
Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs SAS SSDs, SATA SSD (ME), and SATA
SSD (VE) can be mixed.
All drives within a RAID array should be of the same type, capacity and rotation speed.

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 18
4.2.4 RAID 0/1 Controller with 1 GB Cache for 2.5-inch Drives
Product Name / Description
Storage Controller
Required
RAID Controller (1GB, RAID 0/1)
Broadcom MegaRAID SAS 9362-8i
RAID 0/1/10, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
Flash Backup Unit
for Broadcom MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set, for 5th - 8th hard drives
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
NOTE:
Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs SAS SSDs, SATA SSD (ME), and SATA
SSD (VE) can be mixed.
All drives within a RAID array should be of the same type, capacity and rotation speed.
4.2.5 RAID 5/6 Controller with 1 GB Cache for 2.5-inch Drives
Product Name / Description
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
Broadcom MegaRAID SAS 9362-8i
RAID0/1/5/6/10/50/60, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA
6Gb/s
Flash Backup Unit
for Broadcom MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set, for 5th - 8th hard drives
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
NOTE:
Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs SAS SSDs, SATA SSD (ME), and SATA
SSD (VE) can be mixed.
All drives within a RAID array should be of the same type, capacity and rotation speed.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.
4.2.6 RAID 5/6 Controller with 2 GB Cache for 2.5-inch Drives
Product Name / Description
Storage Controller
Required
RAID Controller (2GB, RAID 0/1/5/6)
Broadcom MegaRAID SAS 9362-8i
RAID0/1/5/6/10/50/60, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA
6Gb/s
Flash Backup Unit
for Broadcom MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set, for 5th - 8th hard drives
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
NOTE:
Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs SAS SSDs, SATA SSD (ME), and SATA
SSD (VE) can be mixed.

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 19
All drives within a RAID array should be of the same type, capacity and rotation speed.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.
4.2.7 Embedded SATA non-RAID Controller for 3.5-inch Drives
Product Name / Description
Embedded SATA Controller
4 x 6Gb/s SATA
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA, 1 set
3.5-inch Drive Cage
4 x 3.5-inch Hot-plug hard drive bays
NOTE
Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller.
4.2.8 Embedded SATA RAID Controller for 3.5-inch Drives
Product Name / Description
Embedded SATA Controller
4x 6Gb/s SATA, RAID 0/1/10 capable
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA, 1 set
3.5-inch Drive Cage
4 x 3.5-inch Hot-plug hard drive bays
NOTE:
Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS Support Matrix for PCI
Cards and Embedded Controllers.
All hard drives within a RAID array should be of the same capacity.
4.2.9 RAID 0/1 Controller with 0 MB Cache for 3.5-inch Drives
Product Name / Description
Storage Controller
Required
RAID Controller (RAID 0/1)
Broadcom MegaRAID SAS 9341-8i
RAID 0/1/10, Non-cache, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA, 1 set
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
NOTE:
All hard drives within a RAID array should be of the same capacity.
4.2.10 RAID 0/1 Controller with 1 GB Cache for 3.5-inch Drives
Product Name / Description
Storage Controller
Required
RAID Controller (1GB, RAID 0/1)
Broadcom MegaRAID SAS 9362-8i
RAID 0/1/10, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
Flash Backup Unit
for Broadcom MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA, 1 set
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
NOTE:
All hard drives within a RAID array should be of the same capacity.

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 20
4.2.11 RAID 5/6 Controller with 1 GB Cache for 3.5-inch Drives
Product Name / Description
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
Broadcom MegaRAID SAS 9362-8i
RAID0/1/5/6/10/50/60, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA
6Gb/s
Flash Backup Unit
for Broadcom MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA, 1 set
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
NOTE:
All hard drives within a RAID array should be of the same capacity.
4.2.12 RAID 5/6 Controller with 2 GB Cache for 3.5-inch Drives
Product Name / Description
Storage Controller
Required
RAID Controller (2GB, RAID 0/1/5/6)
Broadcom MegaRAID SAS 9362-8i
RAID0/1/5/6/10/50/60, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA
6Gb/s
Flash Backup Unit
for Broadcom MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA, 1 set
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
NOTE:
All hard drives within a RAID array should be of the same capacity.
4.2.13 Embedded SATA RAID Controller for M.2 SATA SSD
Product Name / Description
Embedded SATA Controller
4x 6Gb/s SATA, RAID 0/1/10 capable
Internal SAS/SATA Cable
1 x Mini SAS HD to 2 x Single SATA, 1 set
Dual M.2 SATA Drive Installation Kit
M.2 PCIe SSD adapter, 2 x M.2 socket
120GB M.2 SATA SSD
1 x 120GB M.2 SATA SSD, 6Gb/s, 512n sector
4.2.14 RAID 0/1 Controller with 0 MB Cache for M.2 SATA SSD
Product Name / Description
Storage Controller
Required
RAID Controller (RAID 0/1)
Broadcom MegaRAID SAS 9341-8i
RAID 0/1/10, Non-cache, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
Internal SAS/SATA Cable
1 x Mini SAS HD to 2 x Single SATA, 1 set
Dual M.2 SATA Drive Installation Kit
M.2 PCIe SSD adapter, 2 x M.2 socket
120GB M.2 SATA SSD
1 x 120GB M.2 SATA SSD, 6Gb/s, 512n sector

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 21
4.2.15 RAID 0/1 Controller with 1 GB Cache for M.2 SATA SSD
Product Name / Description
Storage Controller
Required
RAID Controller (1GB, RAID 0/1)
Broadcom MegaRAID SAS 9362-8i
RAID 0/1/10, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
Internal SAS/SATA Cable
1 x Mini SAS HD to 2 x Single SATA, 1 set
Dual M.2 SATA Drive Installation Kit
M.2 PCIe SSD adapter, 2 x M.2 socket
120GB M.2 SATA SSD
1 x 120GB M.2 SATA SSD, 6Gb/s, 512n sector
4.3 Supported Drives
4.3.1 2.5-inch Drives (1)
Product Name / Description
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
NOTE:
Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller.
4.3.2 2.5-inch Drives (2)
Product Name / Description
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
1.6TB Hot Plug 2.5-inch SATA SSD
1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
4.3.3 2.5-inch Drives (3)
Product Name / Description
Drive
Standard :
4 slots
available
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
600GB 10K Hot Plug 2.5-inch SAS HDD

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 22
Max :
8 slots
available
For 3.5-inch
drive :
2 slots
available
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
900GB 10K Hot Plug 2.5-inch SAS HDD
1 x 900 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1 x 1.2TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
300GB 15K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
450GB 15K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
600GB 15K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
200GB Hot Plug 2.5-inch SAS SSD
1 x 200 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
400GB Hot Plug 2.5-inch SAS SSD
1 x 400 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
1.6TB Hot Plug 2.5-inch SATA SSD
1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
NOTE:
All drives within a RAID array should be of the same type, capacity and rotation speed.
Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs SAS SSDs, SATA SSD (ME), and SATA
SSD (LE) can be mixed.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.
The 2.5-inch SAS/SATA SSDs have limited lifetime. Refer to Endurance of SSD for details.
4.3.4 2.5-inch Drives (4)
Product Name / Description
Drive
Standard :4
slots
available
Max :
8 slots
available
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
900GB 10K Hot Plug 2.5-inch SAS HDD
1 x 900 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1 x 1.2TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
300GB 15K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
450GB 15K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
600GB 15K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 23
1.8TB 10K Hot Plug 2.5-inch SAS HDD
1x 1.8TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512e sector
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
200GB Hot Plug 2.5-inch SAS SSD
1 x 200 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
400GB Hot Plug 2.5-inch SAS SSD
1 x 400 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector VE
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
1.6TB Hot Plug 2.5-inch SATA SSD
1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
NOTE:
All drives within a RAID array should be of the same type, capacity and rotation speed.
Up to two kinds of drives selected from SAS 10K HDDs (512n), SAS 10K HDDs (512e), SAS 15K HDDs, SATA HDDs SAS
SSDs, SATA SSD (ME), and SATA SSD (LE) can be mixed.
For 512e sector HDD, the supported operating systems of virtual machines on Hyper-V are:
- Windows Server 2008 R2 SP1 or later
- Windows 7 SP1 or later
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.
The 2.5-inch SAS/SATA SSDs have limited lifetime. Refer to Endurance of SSD for details.

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 24
4.3.5 3.5-inch Drives (1)
Product Name / Description
500GB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
1TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
2TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
3TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
4TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
NOTE:
Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller.
4.3.6 3.5-inch Drives (2)
Product Name / Description
500GB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
1TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
2TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
3TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
4TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
6TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 6 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512e sector
8TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 8 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512e Sector
10TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 10 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512e Sector
NOTE:
All drives within a RAID array should be of the same capacity.
For 512e sector HDD, the supported operating systems of virtual machines on Hyper-V are:
- Windows Server 2008 R2 SP1 or later
- Windows 7 SP1 or later

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 25
5 Optical Drive
Product Name / Description
Internal
1 slot available
Internal Slim DVD-ROM drive
Slim DVD-ROM drive
DVD read speed: 8x (DVD-ROM / DVD-R / DVD-RW)
CD read speed: 24x (CD-ROM / CD-R/RW)
Internal DVD Super Multi Drive
Slim DVD Super Multi drive, not including writing software
DVD Read speed: 8x (DVD-R / DVD-RW / DVD-R DL / DVD+R /
DVD+RW / DVD+R DL / DVD-ROM)
DVD-RAM read speed: 5x
CD read speed: 24x (CD-ROM / CD-R/RW)
NOTE:
- Not supported for Linux or VMware.
External DVD Dual drive
DVD Dual drive, Bus powered, 1.5A required, not including writing
software
NOTE:
An optical drive is required for maintenance and OS installation.
Up to 1 optical drive can be connected.

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 26
6 PCI Card
Please refer to Supported PCI cards and Installable Slots with regard to the position of PCI slot which can mount PCI card
supported.
6.1 Network Interface Controller
Product Name / Description
1000BASE-T Adapter
Broadcom ® BCM5718 Gigabit Ethernet Controller
PCIe 2.0 x1
Dual Port 1000BASE-T Adapter
Broadcom ® BCM5718 Gigabit Ethernet Controller
PCIe 2.0 x1
Quad Port 1000BASE-T Adapter
Broadcom ® BCM5719 Gigabit Ethernet Controller
PCIe 2.0 x4
NOTE:
- Network cables with RJ-45 plug covers cannot be used.
10GBASE SFP+ Adapter (SFP+/2ch)
Qlogic® NetXtreme II BCM57810 10G SFP+ Dual Port Network
Interface Card
PCIe 2.0 x8
NOTE:
- N8104-129 SFP+ Module is required to connect with an optical cable.
- Up to two SFP+ Modules can be installed.
- Up to two adapters can be installed.
Dual Port 10GBASE-T Adapter
Intel X550-BT2
PCIe 3.0 x4
SFP+ Module (10G-SR)
1 x SFP+ Module for N8104-149
NIC Teaming feature - NIC Teaming and bonding features
See the table below for supported network interfaces and OS combinations.
Windows Server 2012 or later and Linux support teaming with bonding function supported by OS.
1GbE NIC
Embedded 1GbE NIC and
N8104-150/-151/-152
Up to four teams per one system
Up to four ports per one team
Windows Server 2012
Windows Server 2012 R2
Windows Server 2016
Red Hat Enterprise Linux 7
Up to two teams per one system
Up to two ports per one team
Windows Server 2012
Windows Server 2012 R2
Windows Server 2016
Red Hat Enterprise Linux 7
Up to one teams per one system
Up to two ports per one team
Windows Server 2012
Windows Server 2012 R2
Windows Server 2016
Red Hat Enterprise Linux 7
NOTE:
NIC Teaming feature is not supported on iSCSI interfaces.
The network interfaces for each teaming must be the same.
When 10GbE and 1GbE NIC teams are mixed, the teams must be up to four per one system.

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 27
Using iSCSI
See the table below for supported network interfaces and OS combinations.
Embedded 1GbE NIC/
N8104-150/-151/-152
Windows Server 2012, Windows Server 2012 R2, Windows Server 2016,
Red Hat Enterprise Linux 7, VMware
Windows Server 2012, Windows Server 2012 R2, Windows Server 2016,
Red Hat Enterprise Linux 7, VMware
Windows Server 2012, Windows Server 2012 R2,
Windows Server 2016, Red Hat Enterprise Linux 7, VMware
NOTE:
NIC Teaming feature is not supported on iSCSI interfaces.
6.2 External Storage Controller
6.2.1 RAID Controller
Product Name / Description
RAID Controller (2GB, RAID0/1/5/6)
Broadcom MegaRAID SAS 9380-8e
RAID0/1/5/6/10/50/60, 2GB, Ext. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA
6Gb/s, Flash Backup Unit included
NOTE:
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.
It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard
drives failure.
6.2.2 Fibre Channel / SAS Controller
Product Name / Description
Fibre Channel Controller (1ch)
Emulex LightPulse LPe1250-F8 Host Bus Adapter
8Gb/s, Optical, PCIe 2.0 x8
Fibre Channel Controller (2ch)
Emulex LightPulse LPe12002-M8 Host Bus Adapter
8Gb/s, Optical, PCIe 2.0 x8
Fibre Channel Controller (1ch)
QLogic QLE2690-SR-CK Host Bus Adapter
16Gb/s, Optical, PCIe 3.0 x8
Fibre Channel Controller (2ch)
QLogic QLE2692-SR-CK Host Bus Adapter
16Gb/s, Optical, PCIe 3.0 x8
SAS Controller
LSI SAS9212-4i4e Host Bus Adapter
6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8
SAS Controller
LSI SAS9300-8e Host Bus Adapter
12Gb/s SAS, ext. 8(SFF-8644 x2), PCIe 3.0 x8
Product Name / Description
Graphics Accelerator
NVIDIA NVS 315, PCI Express 2.0 (x16)
1x DVI-VGA connector, DMS-59-DVI-I branch cable included
NOTE:
The standard VGA connector cannot be used when this option is installed.
The remote KVM feature is not supported when this option is installed.

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 28
6.4 Serial Port Adapter
Product Name / Description
Serial port adapter
Serial port fixed to PCI bracket
NOTE:
Up to one Serial Port Adapter can be installed.
7 Other Add-in Components
7.1 Cooling Fan Kit
Product Name / Description
Non-redundant Fan Kit
Non-hot plug cooling fan for R110i-1
Redundant Fan Kit
Non-hot plug cooling fan for R110i-1
NOTE:
- The redundant fan kit is necessary to operate the server at temperatures over 40°C with N8181-146F
High temperature resistant Kit
NOTE:
One of the fan kits must be installed.
7.2 Trusted Platform Module Kit
Product Name / Description
Trusted Platform Module Kit
TPM 2.0 module
NOTE:
- Supported for Windows Server 2012 or later only.
NOTE:
The kit is not available in China.
The kit is not removable after attachment.
"TPM Support" in BIOS setup menu must be activated prior to use of this kit.
To use Windows BitLocker drive encryption, be sure to keep the "recovery password" of BitLocker function. The recovery
password is required to restore data for hardware replacement during a system error.
7.3 Internal Flash Memory
Available socket: 1
Product Name / Description
VMware ESXi Base Kit
Internal USB flash memory to install VMware ESXi system
NOTE:
The kit does not include VMware ESXi installation media and license.
7.4 High temperature resistant Kit
Product Name / Description
High temperature resistant Kit
Required for high temperature operation over 40°C (up to 45°C)
NOTE:
Supported for non-hot plug power supply model only.
To apply this option, there are some configuration limitations below.
Required System Configuration:
- N8181-111F Redundant Fan Kit is required.
- Up to 3 hard drives.
- Any of N8103-181 (Flash Backup Unit), N8103-179 (RAID Controller (2GB, RAID0/1/5/6)), N8151-134 (Internal Slim DVD-

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 29
ROM drive) or N8151-135F (Internal DVD Super Multi Drive) must not be installed.
7.5 Flash FDD
Choose the Flash FDD if you need to prepare an alternative device for a floppy drive.
Product Name / Description
Flash FDD
USB flash emulating USB floppy disk, Native capacity 1.44 MB
NOTE:
Up to one drive can be connected.
Not supported when VMware is running on the server.
8 Add-on Components
8.1 17-inch LCD Console Drawer
Product Name / Description
17-inch LCD Console Drawer (8 port)
17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port KVM
switch, 1U height
Switch Unit Connection Cable Set (USB, 1.8m)
1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A
Switch Unit Connection Cable Set (USB, 3m)
3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A
Switch Unit Connection Cable Set (USB, 5m)
5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A
17inch LCD Console Unit 1U
17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height,
4-pin USB B to 4-pin USB A cable 2 m, PS/2 Y-splitter cable 2m, 15pin mini D-sub VGA cable 2 m
17inch LCD Console Drawer (1 port)
17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad with 3button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8 m, Two PS/2
cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m
Keyboard Unit (JP)
JP 108-keys Keyboard with 10-key for N8143-108F 17inch LCD
Console Drawer (1 port)
UK 104-keys Keyboard with 10-key, for N8143-108F 17inch LCD
Console Drawer (1 port)
Product Name / Description
Server Switch Unit (8 server)
1U USB 8 port KVM switch
Switch Unit Connection Cable Set (USB,1.8m)
1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A
Switch Unit Connection Cable Set (USB,3m)
3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A
Switch Unit Connection Cable Set (USB,3m)
5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A
Switch Unit Connection Cable 1.8 m
1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 30
8.3 Server Management License
The server integrates the EXPRESSSCOPE Engine 3 as standard. Refer to Server Management for the standard management
features. For more extensive remote KVM and remote media features, choose the following kit.
Product Name / Description
Remote KVM and Media License Kit
License for one server.
Remote KVM and remote media are enabled regardless of OS status.
Remote KVM:
- Displays a graphics console on the web browser of the remote terminal (PC/server).
- Controls keyboard and mouse via the remote terminals' web browser
Remote media:
- Enables the user to use the CD / DVD / FD / Flash memory of the remote terminals (PC/server) as
if accessing the local drives.
NOTE:
Remote KVM and remote media features are not available for virtual machines.

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 31
References
Boot Mode Setting
The server supports Legacy mode and UEFI mode (default) as an OS Boot Mode. See the table below for the Boot Mode and
X2APIC setting for each Operating System. As the default settings at the factory, UEFI mode is set as OS Boot mode and X2APIC is
enabled. Refer to the User’s Guide and change the settings before installing an Operating System requiring Legacy Mode.
Red Hat Enterprise Linux 7

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 32
Server Management
The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system management features
listed in the table below.
With Remote KVM
and Media License kit
Temperature/fan/voltage/power consumption/System
FAN/degeneration(memory)
Hardware configuration information collection
Hardware event log collection
BIOS/POST stall, Booting, OS stall, shutdown
HW error, Boot error and OS panic
(by SNMP, E-Mail)
POST/BIOS setup, ROM utility
Panic screen, Boot screen
CUI-based screen (OS console)
GUI-based screen (OS console)
Remote reset/power on-off/ dump
Remote BIOS setup(partial configuration only)
Remote media (CD/DVD/FD/USB)
CLP (Command Line Protocol) (DMTF compliant)
Remote control via Web browser (multi user login at the
same time)
Scheduling (without UPS, require NEC ESMPRO
Manager)
BIOS setting by using XML file
EXPRESSSCOPE® Profile key
(Backup/restore BIOS/BMC setup information)
Set automatic IP address via DNS/DHCP
LDAP/Active Directory verification/user control
Clock synchronization of main unit and the RTC
1
The optional serial port is not available for the feature.
2
The feature is not supported on VMware ESXi systems.
3
Monitoring boot screens is not supported on VMware systems.
4
In VMware systems, only the direct console user interface is supported.

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 33
Endurance of SSD
The 2.5-inch SAS/SATA SSDs have limited lifetime, which can only be written a limited number of times before it fails.
The warranty period of SSD is the stated period of warranty or until the total bytes of written value (PBW) exceeds the limit value,
whichever occurs first. It is recommended to check the total bytes of written value periodically.
Refer to the table below for the write endurance (PBW and DWPD), warranty period and monitoring tool.
SSD Lifetime
200GB Hot Plug 2.5-inch SAS SSD
400GB Hot Plug 2.5-inch SAS SSD
SATA SSD (Middle Endurance)
200GB Hot Plug 2.5-inch SATA SSD
400GB Hot Plug 2.5-inch SATA SSD
800GB Hot Plug 2.5-inch SATA SSD
SATA SSD (Value Endurance)
200GB Hot Plug 2.5-inch SATA SSD
400GB Hot Plug 2.5-inch SATA SSD
800GB Hot Plug 2.5-inch SATA SSD
1.6TB Hot Plug 2.5-inch SATA SSD
PBW(Peta-Bytes Write): Total amount of data that can be written into the SSD. 1PB=1,000TB.
DWPD(Drive Writes per Day): Rewrite capacity of the SSD per day.
Check the lifetime of SSD by monitoring tool regularly.
It is recommended to replace the SSD before it reaches its end of life. For repurchase, please contact your sales representative.
For detailed operating methods of monitoring tool, refer to the User’s Guide.

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 34
OS Support Matrix for PCI Cards and Embedded Controllers
WS 2016 WS 2012 R2 WS 2012 RHEL 7 ESXi 6.0 ESXi 5.5
Embedded SATA non-RAID Controller
Embedded SATA RAID Controller
- - - - Embedded 1GbE NIC
RAID controller (RAID0/1)
RAID Controller (1GB, RAID 0/1)
RAID Controller (1GB, RAID 0/1/5/6)
RAID Controller (2GB, RAID 0/1/5/6)
Fibre Channel Controller (2ch)
Fibre Channel Controller (1ch)
RAID Controller (2GB, RAID0/1/5/6)
Dual Port 10GBASE-T Adapter
10GBASE SFP+ Adapter (SFP+/2ch)
Fibre Channel Controller (2ch)
Fibre Channel Controller (1ch)
Quad Port 1000BASE-T Adapter
Dual Port 1000BASE-T Adapter

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 35
Supported PCI cards and Installable Slots
RAID controller (RAID0/1)
RAID Controller (1GB, RAID 0/1)
RAID Controller (1GB, RAID 0/1/5/6)
RAID Controller (2GB, RAID 0/1/5/6)
Fibre Channel Controller (2ch)
Fibre Channel Controller (1ch)
RAID Controller (2GB, RAID0/1/5/6)
Dual Port 10GBASE-T Adapter
10GBASE SFP+ Adapter (SFP+/2ch)
Fibre Channel Controller (2ch)
Fibre Channel Controller (1ch)
Quad Port 1000BASE-T Adapter
Dual Port 1000BASE-T Adapter
Dual M.2 SATA Installation Kit
The number between parentheses shows the population priority (recommendation). For example, install N8103-176 in the slot
#1 and N8104-152 in the slot #2 when you have those cards.
There are PCI slot limitations depending on the processor and operating system. Please refer to the next page and be careful to
choose a processor and PCI cards.

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 36
PCI slot limitations for VMware
Do not install N8104-152 Quad Port 1000BASE-T Adapter when any of the following cards is installed.
- N8104-157 Dual Port 10GBASE-T Adapter
- N8104-149 10GBASE SFP+ Adapter (SFP+/2ch)
For the configuration limitation for VMware ESXi, refer to the following documents.
- VMware ESXi6.0
https://www.vmware.com/pdf/vsphere6/r60/vsphere-60-configuration-maximums.pdf
- VMware ESXi6.5
https://www.vmware.com/pdf/vsphere6/r65/vsphere-65-configuration-maximums.pdf

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 37
Secure Boot Mode
This server supports Secure Boot. It is supported with UEFI Boot mode and protects the security by only allowing software programs
with digital signature to run. The supported operating systems, software, and boot devices are below. The default setting of Secure
Boot is disabled. Keep the setting disabled to use other operating systems and/or software.
Supported OS and Software for Secure Boot Mode
System Diagnostics Utility
Supported Boot Device for Secure Boot Mode
RAID controller (RAID0/1)
RAID controller (1GB, RAID0/1)
RAID controller (1GB, RAID0/1/5/6)
RAID controller (2GB, RAID0/1/5/6)
RAID controller (2GB, RAID0/1/5/6)

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 38
Copyright Notice and Liability Disclaimer
The information contained herein is subject to change without notice.
Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or
other countries
Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other
countries.
Linux is a trademark of Linus Torvalds.
Red Hat is a registered trademark of Red Hat, Inc. in the U.S.
All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective
holders.
NEC shall not be liable for technical or editorial errors or omissions contained herein.
For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less.

SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 39
Revision History
New products added:
120GB M.2 SATA SSD / N8150-736
Dual M.2 SATA Drive Installation Kit / N8118-307
Graphics Accelerator / N8105-48
Others:
Removed support information related to Windows Server 2008 R2