NEC Express5800/R110i-1, R110i-1, N8100-2537F, N8100-2359F, N8100-2360F System Configuration Manual

...
NEC Express5800/R110i-1
System Configuration Guide
Introduction
This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC Express5800 server.
June 6, 2017 Revision 2.0
NEC Corporation
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 2
Contents
TECHNICAL SPECIFICATION ........................................................................................ 3
Specification .......................................................................................................................................... 3
EXTERNAL VIEWS ......................................................................................................... 8
Front and Rear Views ........................................................................................................................... 8
Dimensions (mm) ................................................................................................................................ 10
CONFIGURATION DIAGRAM ....................................................................................... 11
EXPANSION SLOTS ..................................................................................................... 12
SERVER CONFIGURATION ......................................................................................... 13
1 Base Models ........................................................................................................................... 13
2 Processor................................................................................................................................ 13
3 Memory ................................................................................................................................... 14
4 Internal Hard Disk Drives ........................................................................................................ 15
4.1 RAID Configuration .............................................................................................................. 15
4.2 Required Components for RAID Configuration ................................................................... 17
4.3 Supported Drives ................................................................................................................. 21
5 Optical Drive ........................................................................................................................... 25
6 PCI Card ................................................................................................................................. 26
6.1 Network Interface Controller ................................................................................................ 26
6.2 External Storage Controller ................................................................................................. 27
Graphics Accelerator ........................................................................................................... 27
6.4 Serial Port Adapter .............................................................................................................. 28
7 Other Add-in Components ...................................................................................................... 28
7.1 Cooling Fan Kit .................................................................................................................... 28
7.2 Trusted Platform Module Kit ................................................................................................ 28
7.3 Internal Flash Memory ......................................................................................................... 28
7.4 High temperature resistant Kit ............................................................................................. 28
7.5 Flash FDD............................................................................................................................ 29
8 Add-on Components ............................................................................................................... 29
8.1 17-inch LCD Console Drawer .............................................................................................. 29
8.2 KVM Switch ......................................................................................................................... 29
8.3 Server Management License............................................................................................... 30
REFERENCES............................................................................................................... 31
Boot Mode Setting .............................................................................................................................. 31
Server Management ............................................................................................................................ 32
Endurance of SSD ............................................................................................................................... 33
OS Support Matrix for PCI Cards and Embedded Controllers ....................................................... 34
Supported PCI cards and Installable Slots....................................................................................... 35
Secure Boot Mode ............................................................................................................................... 37
Copyright Notice and Liability Disclaimer ........................................................................................ 38
REVISION HISTORY ..................................................................................................... 39
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 3
Technical Specification
Specification
2.5-inch Drive Model (1/2)
Model
R110i-1
Part Number
N8100-2537F
Processor
Type
Intel® Pentium® Processor G4560
Intel® Xeon® Processor E3-1220 v6
Intel® Xeon® Processor E3-1225 v6
Intel® Xeon® Processor E3-1230 v6
Clock Speed
3.50 GHz
3.00 GHz
3.30 GHz
3.50 GHz
Number of Processor
1
Cache
3 MB
8 MB
Cores and Threads
2C / 4T
4C / 4T
4C / 8T
Chipset
Intel® C236 Chipset
Memory
Type
DDR4-2400 ECC Unbuffered DIMM
Standard Capacity
0 GB
Maximum Capacity
64 GB (4 x 16 GB)
Internal Storage
Standard Capacity
0 GB
Maximum Capacity
SATA HDD: 16 TB (8 x 2 TB) SAS HDD : 14.4 TB (8 x 1.8 TB) SATA SSD 12.8 TB (8 x 1.6 TB) SAS SSD 3.2 TB (8 x 400 GB)
Disk Controller
SATA : 6 Gb/s (Integrated) SATA/SAS : 6/12 Gb/s (Optional)
RAID
SATA : RAID 0/1/10 (Standard
1
)
SATA/SAS : RAID 0/1/5/6/10/50/60 (Optional)
Hot Plug
Supported
Optical Disk Drive
Optional
Optical Drive Bays
1
Disk Drive Bays
8
Expansion Slots
Total: 3 slots available 1 PCIe 3.0 x16 (x16 connector) 1 PCIe 3.0 x4 (x8 connector) 1 PCIe 3.0 x4 (x8 connector) dedicated RAID slot
Video
Controller (VRAM)
Integrated in Server Management Controller (32MB)
Resolution / Color
1600 x 1200 / 16.7M 2
Interfaces
1 VGA (15-pin mini D-sub,1 rear) 1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear) 6 USB 3.0 (2 front, 4 rear) (plus 1 internal USB 3.0) 2 1000BASE-T LAN connector (RJ-45, 2 rear) 1 1000BASE-T LAN connector for management (RJ-45, 1 rear)
Server Management
EXPRESSSCOPE Engine 3
Redundant Fan
Optional, non-hot plug
Power Supply
2 450 Watt 80 PLUS® Gold certified Hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Power Consumption
(Max. Config, Idling)
123 VA / 122 Watt
122 VA / 121 Watt
125 VA / 124 Watt
123 VA / 122 Watt
(Max. Config, Operating)
284 VA / 282 Watt
325 VA / 323 Watt
320 VA / 318 Watt
347 VA / 345 Watt
Acoustic Noise (Sound Pressure Level) 3
Minimum Config.
46 dB
Maximum Config.
49 dB
Dimensions (W x D x H )
444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U)
Weight (Minimum / Maximum)
10 kg / 17.5 kg, 22.05 lbs. / 38.58 lbs.
Temperature, Relative Humidity (non-condensing)
Operating: 5° to 40° C / 41° to 104° F (Standard) or 5° to 45° C / 41° to 113° F (Optional), 10 to 85% Non-Operating: -10° to 55° C / 14° to 131° F, 10 to 85%
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 4
Model
R110i-1
Regulatory and Safety
FCC, c-UL, CE, CB, RoHS, WEEE, BSMI, CCC
Operating Systems and Virtualization Software
Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter Microsoft® Windows Server® 2012 R2 Standard Microsoft® Windows Server® 2012 R2 Datacenter Microsoft® Windows Server® 2016 Standard Microsoft® Windows Server® 2016 Datacenter Red Hat Enterprise Linux 7.3 or later
4
VMware ESXi 6.0 Update 3
5
VMware ESXi 6.5
5
1
Embedded SATA RAID controller is supported only on limited operating systems.
2
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
3
Noise emission was measured in accordance with ISO 7779, at 25°C. The actual value may vary by the operating environment.
4
For Linux support, contact your sales representative or visit the NEC website at:
http://www.nec.com/en/global/prod/express/linux/index.html
5
Supported on Xeon processor systems only.
(2/2)
Model
R110i-1
Part Number
N8100-2537F
Processor
Type
Intel® Xeon® Processor E3-1240L v5
Intel® Xeon® Processor
E3-1260L
v5
Intel® Xeon® Processor E3-1270 v6
Clock Speed
2.10 GHz
2.90 GHz
3.80 GHz
Number of Processor
1
Cache
8 MB Cores and Threads
4C / 8T
Chipset
Intel® C236 Chipset
Memory
Type
DDR4-2400 ECC Unbuffered DIMM
Standard Capacity
0 GB Maximum Capacity
64 GB (4 x 16 GB)
Internal Storage
Standard Capacity
0 GB
Maximum Capacity
SATA HDD: 16 TB (8 x 2 TB) SAS HDD : 14.4 TB (8 x 1.8 TB) SATA SSD 12.8 TB (8 x 1.6 TB) SAS SSD 3.2 TB (8 x 400 GB)
Disk Controller
SATA : 6 Gb/s (Integrated) SATA/SAS : 6/12 Gb/s (Optional)
RAID
SATA : RAID 0/1/10 (Standard
1
)
SATA/SAS : RAID 0/1/5/6/10/50/60 (Optional)
Hot Plug
Supported
Optical Disk Drive
Optional
Optical Drive Bays
1
Disk Drive Bays
8
Expansion Slots
Total: 3 slots available 1 PCIe 3.0 x16 (x16 connector) 1 PCIe 3.0 x4 (x8 connector) 1 PCIe 3.0 x4 (x8 connector) dedicated RAID slot
Video
Controller (VRAM)
Integrated in Server Management Controller (32MB)
Resolution / Color
1600 x 1200 / 16.7M 2
Interfaces
1 VGA (15-pin mini D-sub,1 rear) 1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear) 6 USB 3.0 (2 front, 4 rear) (plus 1 internal USB 3.0) 2 1000BASE-T LAN connector (RJ-45, 2 rear) 1 1000BASE-T LAN connector for management (RJ-45, 1 rear)
Server Management
EXPRESSSCOPE Engine 3
Redundant Fan
Optional, non-hot plug
Power Supply
2 450 Watt 80 PLUS® Gold certified Hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Power Consumption
(Max. Config, Idling)
117 VA / 116 W
119 VA / 118 W
124 VA / 123 Watt
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 5
Model
R110i-1
(Max. Config, Operating)
170 VA / 169 W
198 VA / 197 Watt
251 VA / 249 Watt
Acoustic Noise (Sound Pressure Level) 3
Minimum Config.
46 dB
Maximum Config.
49 dB
Dimensions (W x D x H )
444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U)
Weight (Minimum / Maximum)
10 kg / 17.5 kg, 22.05 lbs. / 38.58 lbs.
Temperature, Relative Humidity (non-condensing)
Operating: 5° to 40° C / 41° to 104° F (Standard) or 5° to 45° C / 41° to 113° F (Optional), 10 to 85% Non-Operating: -10° to 55° C / 14° to 131° F, 10 to 85%
Regulatory and Safety
FCC, c-UL, CE, CB, RoHS, WEEE, BSMI, CCC
Operating Systems and Virtualization Software
Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter Microsoft® Windows Server® 2012 R2 Standard Microsoft® Windows Server® 2012 R2 Datacenter Microsoft® Windows Server® 2016 Standard Microsoft® Windows Server® 2016 Datacenter Red Hat Enterprise Linux 7.3 or later
4
VMware ESXi 6.0 Update 3
5
VMware ESXi 6.5
5
1
Embedded SATA RAID controller is supported only on limited operating systems.
2
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
3
Noise emission was measured in accordance with ISO 7779, at 25°C. The actual value may vary by the operating environment.
4
For Linux support, contact your sales representative or visit the NEC website at:
http://www.nec.com/en/global/prod/express/linux/index.html
3.5-inch Drive Model (1/2)
Model
R110i-1
Part Number
N8100-2359F, N8100-2360F
Processor
Type
Intel® Pentium® Processor G4560
Intel® Xeon® Processor E3-1220 v6
Intel® Xeon® Processor E3-1225 v6
Intel® Xeon® Processor E3-1230 v6
Clock Speed
3.50 GHz
3.00 GHz
3.30 GHz
3.50 GHz
Number of Processor
1
Cache
3 MB
8 MB Cores and Threads
2C / 4T
4C / 4T
4C / 8T
Chipset
Intel® C236 Chipset
Memory
Type
DDR4-2400 ECC Unbuffered DIMM
Standard Capacity
0 GB
Maximum Capacity
64 GB (4 x 16 GB)
Internal Storage
Standard Capacity
0 GB
Maximum Capacity
SATA : 40 TB (4 x 10 TB)
Disk Controller
SATA : 6Gb/s (Integrated)
RAID
SATA : RAID 0/1/10 (Standard 1 ), RAID 5/6 (Optional)
Hot Plug
Supported
Optical Disk Drive
Optional
Optical Drive Bays
1
Disk Drive Bays
4
Expansion Slots
Total: 3 slots available 1 PCIe 3.0 x16 (x16 connector) 1 PCIe 3.0 x4 (x8 connector) 1 PCIe 3.0 x4 (x8 connector) dedicated RAID slot
Video
Controller (VRAM)
Integrated in Server Management Controller (32MB)
Resolution / Color
1600 x 1200 / 16.7M 2
Interfaces
1 VGA (15-pin mini D-sub,1 rear) 1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear) 6 USB 3.0 (2 front, 4 rear) (plus 1 internal USB 3.0)
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 6
Model
R110i-1
2 1000BASE-T LAN connector (RJ-45, 2 rear) 1 1000BASE-T LAN connector for management (RJ-45, 1 rear)
Server Management
EXPRESSSCOPE Engine 3
Redundant Fan
Optional, non-hot plug
Power Supply
1 400 Watt 80 PLUS® Platinum certified non-Hot plug PSU 2 450 Watt 80 PLUS® Gold certified Hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Power Consumption
(Max. Config, Idling)
116 VA / 115 Watt
116 VA / 115 Watt
116 VA / 115 Watt
117 VA / 116 Watt
(Max. Config, Operating)
158 VA / 157 Watt
195 VA / 194 Watt
194 VA / 193 Watt
224 VA / 222 Watt
Acoustic Noise (Sound Pressure Level) 3
Minimum Config.
40 dB
Maximum Config.
49 dB
Dimensions (W x D x H )
444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U)
Weight (Minimum / Maximum)
10 kg / 17.5 kg, 22.05 lbs. / 38.58 lbs.
Temperature, Relative Humidity (non-condensing)
Operating: 5° to 40° C / 41° to 104° F (Standard) or 5° to 45° C / 41° to 113° F (Optional), 10 to 85% Non-Operating: -10° to 55° C / 14° to 131° F, 10 to 85%
Regulatory and Safety
FCC, c-UL, CE, CB, RoHS, WEEE, BSMI, CCC
Operating Systems and Virtualization Software
Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter Microsoft® Windows Server® 2012 R2 Standard Microsoft® Windows Server® 2012 R2 Datacenter Microsoft® Windows Server® 2016 Standard Microsoft® Windows Server® 2016 Datacenter Red Hat Enterprise Linux 7.3 or later
4
VMware ESXi 6.0 Update 3
5
VMware ESXi 6.5
5
1
Embedded SATA RAID controller is supported only on limited operating systems.
2
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
3
Noise emission was measured in accordance with ISO 7779, at 25°C. The actual value may vary by the operating environment.
4
For Linux support, contact your sales representative or visit the NEC website at:
http://www.nec.com/en/global/prod/express/linux/index.html
5
Supported on Xeon processor systems only.
(2/2)
Model
R110i-1
Part Number
N8100-2359F, N8100-2360F
Processor
Type
Intel® Xeon® Processor E3-1240L v5
Intel® Xeon® Processor
E3-1260L
v5
Intel® Xeon® Processor E3-1270 v6 Clock Speed
2.10 GHz
2.90 GHz
3.80 GHz
Number of Processor
1
Cache
8 MB
Cores and Threads
4C / 8T
Chipset
Intel® C236 Chipset
Memory
Type
DDR4-2400 ECC Unbuffered DIMM
Standard Capacity
0 GB
Maximum Capacity
64 GB (4 x 16 GB)
Internal Storage
Standard Capacity
0 GB
Maximum Capacity
SATA : 40 TB (4 x 10 TB)
Disk Controller
SATA : 6Gb/s (Integrated)
RAID
SATA : RAID 0/1/10 (Standard 1 ), RAID 5/6 (Optional)
Hot Plug
Supported
Optical Disk Drive
Optional
Optical Drive Bays
1
Disk Drive Bays
4
Expansion Slots
Total: 3 slots available 1 PCIe 3.0 x16 (x16 connector) 1 PCIe 3.0 x4 (x8 connector)
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 7
Model
R110i-1
1 PCIe 3.0 x4 (x8 connector) dedicated RAID slot
Video
Controller (VRAM)
Integrated in Server Management Controller (32MB)
Resolution / Color
1600 x 1200 / 16.7M 2
Interfaces
1 VGA (15-pin mini D-sub,1 rear) 1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear) 6 USB 3.0 (2 front, 4 rear) (plus 1 internal USB 3.0) 2 1000BASE-T LAN connector (RJ-45, 2 rear) 1 1000BASE-T LAN connector for management (RJ-45, 1 rear)
Server Management
EXPRESSSCOPE Engine 3
Redundant Fan
Optional, non-hot plug
Power Supply
1 400 Watt 80 PLUS® Platinum certified non-Hot plug PSU 2 450 Watt 80 PLUS® Gold certified Hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Power Consumption
(Max. Config, Idling)
117 VA / 116 Watt
116 VA / 115 Watt
117 VA / 116 Watt
(Max. Config, Operating)
155 VA / 154 Watt
183 VA / 182 Watt
226 VA / 224 Watt
Acoustic Noise (Sound Pressure Level) 3
Minimum Config.
40 dB
Maximum Config.
49 dB
Dimensions (W x D x H )
444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U)
Weight (Minimum / Maximum)
10 kg / 17.5 kg, 22.05 lbs. / 38.58 lbs.
Temperature, Relative Humidity (non-condensing)
Operating: 5° to 40° C / 41° to 104° F (Standard) or 5° to 45° C / 41° to 113° F (Optional), 10 to 85% Non-Operating: -10° to 55° C / 14° to 131° F, 10 to 85%
Regulatory and Safety
FCC, c-UL, CE, CB, RoHS, WEEE, BSMI, CCC
Operating Systems and Virtualization Software
Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter Microsoft® Windows Server® 2012 R2 Standard Microsoft® Windows Server® 2012 R2 Datacenter Microsoft® Windows Server® 2016 Standard Microsoft® Windows Server® 2016 Datacenter Red Hat Enterprise Linux 7.3 or later
4
VMware ESXi 6.0 Update 3
5
VMware ESXi 6.5
5
1
Embedded SATA RAID controller is supported only on limited operating systems.
2
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
3
Noise emission was measured in accordance with ISO 7779, at 25°C. The actual value may vary by the operating environment.
4
For Linux support, contact your sales representative or visit the NEC website at:
http://www.nec.com/en/global/prod/express/linux/index.html
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 8
External Views
Front and Rear Views
Front View for 2.5-inch Drive Model
Front View for 3.5-inch Drive Model
Legend
A.
Drive Bays
H.
Dump (NMI) Switch
B.
Optical Drive Bay
I.
BMC Reset Button
C.
USB Connector
J.
System Status LED 1
D.
USB Connector
K.
System Status LED 2
E.
Power Button / Power LED
L.
Power Capping LED
F.
UID LED Button
M.
Data LAN 1 Activity LED
G.
Reset Button
N.
Data LAN 2 Activity LED
B
A
C
D
E F G H I J K L
M N
B
A
C
D
E F G H I J K L
M N
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 9
Rear View for Non-redundant PSU Configuration
Rear View for Redundant PSU Configuration
Legend
A.
PCI Slot 1B
G.
Power LED
B.
PCI Slot 1C
H.
Data LAN 1 Connector
C.
AC Inlet
I.
Data LAN 2 Connector
D.
Power Unit
J.
USB 3.0 Connectors
E.
Serial Port Connector
K.
Management LAN Connector
F.
VGA Connector
L.
UID LED / Button
C
J
L
D
A
B
H
E
F
I
G
K
D
A
B
H I
K L
E
FC
D
C
J
G
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 10
Dimensions (mm)
Non-Hot plug PSU Configuration
Hot plug PSU Configuration
43.6 mm
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 11
Configuration Diagram
2.5-inch Drive Model
Legend: Standard Components Mandatory components
3.5-inch Drive Model (Non-redundant PSU)
Legend: Standard Components Mandatory components
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 12
3.5-inch Drive Model (Redundant PSU)
Legend: Standard Components Mandatory components
Expansion Slots
Legend
#1A
PCIe 3.0 (x4) x4 lanes, x8 connector, for a dedicated RAID controller
#1B
PCIe 3.0 (x16) x16 lanes, x16 connector, Low profile, up to 173 mm length
#1C
PCIe 3.0 (x4) x4 lanes, x8 connector, Low profile, up to 173 mm length
PCI 1B
PCI 1C
PCI 1A
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 13
Server Configuration
1 Base Models
Product Name / Description
Part Number
NEC Express5800/R110i-1
No CPU, no RAM, no 3.5-inch HDD, no Cooling FAN, no ODD Including:
3.5-inch Drive Cage, 1x 400 Watt non-hot plug power supply, Front bezel
N8100-2359F
NEC Express5800/R110i-1
No CPU, no RAM, no 3.5-inch HDD, no Cooling FAN, no ODD Including:
3.5-inch Drive Cage, 2 x 450 Watt hot plug power supply, Front bezel
N8100-2360F
NEC Express5800/R110i-1
No CPU, no RAM, no 2.5-inch HDD, no Cooling FAN, no ODD Including:
2.5-inch Drive Cage, 2 x 450 Watt hot plug power supply, Front bezel,
N8100-2537F
NOTE:
The base model must be ordered with a processor kit, a memory kit, a cooling fan kit, and internal hard drive cable
2 Processor
Available sockets: 1
Category
Product Name / Description
Part Number
Processors
Required
Pentium G4560 Processor Kit
Intel® Pentium ® Processor G4560 (3.50 GHz, 2C/4T, 3 MB)
N8101-1086F
Xeon E3-1220 v6 Processor Kit
Intel® Xeon ® Processor E3-1220 v6 (3 GHz, 4C/4T, 8 MB)
N8101-1091F
Xeon E3-1225 v6 Processor Kit
Intel® Xeon ® Processor E3-1225 v6 (3.30 GHz, 4C/4T, 8 MB)
N8101-1090F
Xeon E3-1230 v6 Processor Kit
Intel® Xeon ® Processor E3-1230 v6 (3.50 GHz, 4C/8T, 8 MB)
N8101-1089F
Xeon E3-1240L v5 Processor Kit
Intel® Xeon ® Processor E3-1240L v5 (2.10 GHz, 4C/8T, 8 MB)
N8101-943F
Xeon E3-1260L v5 Processor Kit
Intel® Xeon ® Processor E3-1260L v5 (2.90 GHz, 4C/8T, 8 MB)
N8101-944F
Xeon E3-1270 v6 Processor Kit
Intel® Xeon ® Processor E3-1270 v6 (3.80 GHz, 4C/8T, 8 MB)
N8101-1088F
NOTE:
The processor kit must be ordered with the base model. VMware ESXi is not supported on Pentium processor systems.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 14
3 Memory
Available slots: 4
Product Name / Description
Part Number
4GB DDR4-2400 UNB Memory Kit
4GB Unbuffered ECC DIMM, DDR4-2400
N8102-700F
8GB DDR4-2400 UNB Memory Kit
8GB Unbuffered ECC DIMM, DDR4-2400
N8102-701F
16GB DDR4-2400 UNB Memory Kit
16GB Unbuffered ECC DIMM, DDR4-2400
N8102-702F
NOTE:
Minimum one memory kit must be installed. It is recommended to install memory kits in pairs of two identical DIMMs for dual-channel symmetric memory configurations to
increase memory transfer speed.
At least 5 GB of memory is required for VMware ESXi™ 5.5 and VMware ESXi™ 6.0
Maximum Available Memory
See the table below for the maximum memory size that you can actually use on your system. The maximum available memory is less than the maximum physical memory supported by your system because some chipsets
require PCI resource space of about 750MB. PCI resource requirements vary depending on the type and the number of PCI cards you are using.
Maximum Memory Size Supported by Operating Systems
Maximum Available Memory
Microsoft Windows Server 2012 Standard Microsoft Windows Server 2012 Datacenter Microsoft Windows Server 2012 R2 Standard Microsoft Windows Server 2012 R2 Datacenter
4 TB 1
64 GB
Microsoft Windows Server 2016 Standard Microsoft Windows Server 2016 Datacenter
24TB 1
64GB Red Hat Enterprise Linux 7
6 TB
64 GB
VMware ESXi 6.0
6 TB 2
64 GB
VMware ESXi 6.5
12 TB 3
64 GB
1
The maximum available memory size of Hyper-V systems are below:
- Windows Server 2012, Windows Server 2012 R2 : 4 TB
- Windows Server 2016 : 24 TB
2
Up to 4 TB of main memory is available to each virtual machine.
3
Up to 6 TB of main memory is available to each virtual machine.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 15
4 Internal Hard Disk Drives
4.1 RAID Configuration
Refer to the section in accordance with your disk form factor and RAID configuration.
4.1.1 2.5-inch Drive
Operating System
Supported RAID configuration
Supported
HDD/SSD RAID and Cache
Section
VMware ESXi 6.0
Non-RAID (Embedded SATA)
4.2.1
4.3.1
RAID 0/1/10 No Cache
4.2.3
4.3.3
RAID 0/1/10 1GB Cache
4.2.4
RAID 5/6/50/60 1GB Cache
4.2.5
RAID 5/6/50/60 2GB Cache
4.2.6
Windows Server 2012 Windows Server 2012 R2 Windows Server 2016
Non-RAID (Embedded SATA)
4.2.1
4.3.1
RAID 0/1 (Embedded SATA RAID)
4.2.2
4.3.2
RAID 0/1/10 No Cache
4.2.3
4.3.4
RAID 0/1/10 1GB Cache
4.2.4
RAID 5/6/50/60 1GB Cache
4.2.5
RAID 5/6/50/60 2GB Cache
4.2.6
Red Hat Enterprise Linux 7 VMware ESXi 6.5
Non-RAID (Embedded SATA)
4.2.1
4.3.1
RAID 0/1/10 No Cache
4.2.3
4.3.4
RAID 0/1/10 1GB Cache
4.2.4
RAID 5/6/50/60 1GB Cache
4.2.5
RAID 5/6/50/60 2GB Cache
4.2.6
NOTE:
Up to four drives can be installed when you choose the Embedded SATA non-RAID controller. All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs (512n), SAS 10K HDDs (512e), SAS 15K HDDs, SATA HDDs SAS
SSDs, SATA SSD (ME), and SATA SSD (VE) can be mixed.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.
Slot 2
Slot 3
Slot 4 Slot 5
Slot 6 Slot 7
Slot 0
Slot 1
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 16
4.1.2 3.5-inch Drive
Operating System
Supported RAID configuration
Supported
HDD/SSD RAID and Cache
Section
VMware ESXi 6.0
Non-RAID (Embedded SATA)
4.2.7
4.3.5
RAID 0/1/10 No Cache
4.2.9
RAID 0/1/10 1GB Cache
4.2.10
RAID 5/6/50/60 1GB Cache
4.2.11
RAID 5/6/50/60 2GB Cache
4.2.12
Windows Server 2012 Windows Server 2012 R2 Windows Server 2016
Non-RAID (Embedded SATA)
4.2.7
4.3.5
RAID 0/1 (Embedded SATA RAID)
4.2.8
4.3.6
RAID 0/1/10 No Cache
4.2.9
RAID 0/1/10 1GB Cache
4.2.10
RAID 5/6/50/60 1GB Cache
4.2.11
RAID 5/6/50/60 2GB Cache
4.2.12
Red Hat Enterprise Linux 7 VMware ESXi 6.5
Non-RAID (Embedded SATA)
4.2.7
4.3.5
RAID 0/1/10 No Cache
4.2.9
4.3.6
RAID 0/1/10 1GB Cache
4.2.10
RAID 5/6/50/60 1GB Cache
4.2.11
RAID 5/6/50/60 2GB Cache
4.2.12
NOTE:
All hard drives within a RAID array should be of the same capacity.
4.1.3 M.2 SATA SSD
The M.2 SATA SSD can be used for boot drive only. See the table below for the system configuration of M.2 SATA SSD and support for the mixed installation of M.2 SATA SSDs and internal hard drives.
Operating System
M.2 SATA SSD configuration
Support for the mixed
installation of M.2 SATA
SSD and internal hard
drives.
RAID and Cache
Section
Red Hat Enterprise Linux 7 VMware ESXi 6.0 VMware ESXi 6.5
RAID 0/1/10 No Cache
4.2.14
Not supported RAID 0/1/10 1GB Cache
4.2.15
Windows Server 2012 Windows Server 2012 R2 Windows Server 2016
RAID 0/1 (Embedded SATA RAID)
4.2.13
Supported: Optional RAID controller is required to install internal hard drives.
RAID 0/1/10 No Cache
4.2.14
Not supported RAID 0/1/10 1GB Cache
4.2.15
Slot 0 Slot 1 Slot 2 Slot 3
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 17
4.2 Required Components for RAID Configuration
4.2.1 Embedded SATA non-RAID Controller for 2.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4 x 6Gb/s SATA
(Standard)
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set
(Standard)
Drive Cage
2.5-inch Drive Cage
8 x 2.5-inch Hot-plug hard drive bays
(Standard)
NOTE:
Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller.
4.2.2 Embedded SATA RAID Controller for 2.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4x 6Gb/s SATA, RAID 0/1/10 capable
(Standard)
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set
(Standard)
Drive Cage
2.5-inch Drive Cage
8 x 2.5-inch Hot-plug hard drive bays
(Standard)
NOTE
Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS Support Matrix for PCI
Cards and Embedded Controllers.
All hard drives within a RAID array should be of the same capacity.
4.2.3 RAID 0/1 Controller without Cache for 2.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (RAID 0/1)
Broadcom MegaRAID SAS 9341-8i RAID 0/1/10, non-cache, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-188
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set
(Standard)
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set, for 5th - 8th hard drives
K410-348(00)
Drive Cage
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
(Standard)
NOTE:
Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs SAS SSDs, SATA SSD (ME), and SATA
SSD (VE) can be mixed.
All drives within a RAID array should be of the same type, capacity and rotation speed.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 18
4.2.4 RAID 0/1 Controller with 1 GB Cache for 2.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1)
Broadcom MegaRAID SAS 9362-8i RAID 0/1/10, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-176
Flash Backup
Recommended
Flash Backup Unit
for Broadcom MegaRAID SAS 9362-8i 650mm Cable for Flash Backup Unit included
N8103-181
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set
(Standard)
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set, for 5th - 8th hard drives
K410-348(00)
Drive Cage
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
(Standard)
NOTE:
Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs SAS SSDs, SATA SSD (ME), and SATA
SSD (VE) can be mixed.
All drives within a RAID array should be of the same type, capacity and rotation speed.
4.2.5 RAID 5/6 Controller with 1 GB Cache for 2.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
Broadcom MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA
6Gb/s
N8103-177
Flash Backup
Recommended
Flash Backup Unit
for Broadcom MegaRAID SAS 9362-8i 650mm Cable for Flash Backup Unit included
N8103-181
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set
(Standard)
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set, for 5th - 8th hard drives
K410-348(00)
Drive Cage
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
(Standard)
NOTE:
Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs SAS SSDs, SATA SSD (ME), and SATA
SSD (VE) can be mixed.
All drives within a RAID array should be of the same type, capacity and rotation speed. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.
4.2.6 RAID 5/6 Controller with 2 GB Cache for 2.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (2GB, RAID 0/1/5/6)
Broadcom MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-178
Flash Backup
Recommended
Flash Backup Unit
for Broadcom MegaRAID SAS 9362-8i 650mm Cable for Flash Backup Unit included
N8103-181
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set
(Standard)
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set, for 5th - 8th hard drives
K410-348(00)
Drive Cage
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
(Standard)
NOTE:
Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs SAS SSDs, SATA SSD (ME), and SATA
SSD (VE) can be mixed.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 19
All drives within a RAID array should be of the same type, capacity and rotation speed. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.
4.2.7 Embedded SATA non-RAID Controller for 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4 x 6Gb/s SATA
(Standard)
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA, 1 set
(Standard)
Drive Cage
3.5-inch Drive Cage
4 x 3.5-inch Hot-plug hard drive bays
(Standard)
NOTE
Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller.
4.2.8 Embedded SATA RAID Controller for 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4x 6Gb/s SATA, RAID 0/1/10 capable
(Standard)
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA, 1 set
(Standard)
Drive Cage
3.5-inch Drive Cage
4 x 3.5-inch Hot-plug hard drive bays
(Standard)
NOTE:
Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS Support Matrix for PCI
Cards and Embedded Controllers.
All hard drives within a RAID array should be of the same capacity.
4.2.9 RAID 0/1 Controller with 0 MB Cache for 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (RAID 0/1)
Broadcom MegaRAID SAS 9341-8i RAID 0/1/10, Non-cache, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-188
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA, 1 set
(Standard)
Drive Cage
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
(Standard)
NOTE:
All hard drives within a RAID array should be of the same capacity.
4.2.10 RAID 0/1 Controller with 1 GB Cache for 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1)
Broadcom MegaRAID SAS 9362-8i RAID 0/1/10, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-176
Flash Backup
Recommended
Flash Backup Unit
for Broadcom MegaRAID SAS 9362-8i 650mm Cable for Flash Backup Unit included
N8103-181
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA, 1 set
(Standard)
Drive Cage
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
(Standard)
NOTE:
All hard drives within a RAID array should be of the same capacity.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 20
4.2.11 RAID 5/6 Controller with 1 GB Cache for 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
Broadcom MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-177
Flash Backup Recommended
Flash Backup Unit
for Broadcom MegaRAID SAS 9362-8i 650mm Cable for Flash Backup Unit included
N8103-181
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA, 1 set
(Standard)
Drive Cage
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
(Standard)
NOTE:
All hard drives within a RAID array should be of the same capacity.
4.2.12 RAID 5/6 Controller with 2 GB Cache for 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (2GB, RAID 0/1/5/6)
Broadcom MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-178
Flash Backup
Recommended
Flash Backup Unit
for Broadcom MegaRAID SAS 9362-8i 650mm Cable for Flash Backup Unit included
N8103-181
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA, 1 set
(Standard)
Drive Cage
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
(Standard)
NOTE:
All hard drives within a RAID array should be of the same capacity.
4.2.13 Embedded SATA RAID Controller for M.2 SATA SSD
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4x 6Gb/s SATA, RAID 0/1/10 capable
(Standard)
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 2 x Single SATA, 1 set
K410-365(00)
Installation Kit
Dual M.2 SATA Drive Installation Kit
M.2 PCIe SSD adapter, 2 x M.2 socket
N8118-307
Drive
2 slots available
120GB M.2 SATA SSD
1 x 120GB M.2 SATA SSD, 6Gb/s, 512n sector
N8150-736
4.2.14 RAID 0/1 Controller with 0 MB Cache for M.2 SATA SSD
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (RAID 0/1)
Broadcom MegaRAID SAS 9341-8i RAID 0/1/10, Non-cache, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-188
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 2 x Single SATA, 1 set
K410-365(00)
Installation Kit
Dual M.2 SATA Drive Installation Kit
M.2 PCIe SSD adapter, 2 x M.2 socket
N8118-307
Drive
2 slots available
120GB M.2 SATA SSD
1 x 120GB M.2 SATA SSD, 6Gb/s, 512n sector
N8150-736
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 21
4.2.15 RAID 0/1 Controller with 1 GB Cache for M.2 SATA SSD
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1)
Broadcom MegaRAID SAS 9362-8i RAID 0/1/10, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-176
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 2 x Single SATA, 1 set
K410-365(00)
Installation Kit
Dual M.2 SATA Drive Installation Kit
M.2 PCIe SSD adapter, 2 x M.2 socket
N8118-307
Drive
2 slots available
120GB M.2 SATA SSD
1 x 120GB M.2 SATA SSD, 6Gb/s, 512n sector
N8150-736
4.3 Supported Drives
4.3.1 2.5-inch Drives (1)
Category
Product Name / Description
Part Number
Drive
4 slots available
SATA HDD
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-488
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-489
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-527
NOTE:
Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller.
4.3.2 2.5-inch Drives (2)
Category
Product Name / Description
Part Number
Drive
4 slots available
SATA HDD
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-488
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-489
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-527
SATA SSD (ME)
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
N8150-725
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
N8150-726
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
N8150-727
SATA SSD (VE)
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
N8150-732
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
N8150-733
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
N8150-734
1.6TB Hot Plug 2.5-inch SATA SSD
1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
N8150-735
4.3.3 2.5-inch Drives (3)
Category
Product Name / Description
Part Number
Drive
Standard :
4 slots available
SAS HDD (512n)
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-479
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-480
600GB 10K Hot Plug 2.5-inch SAS HDD
N8150-481
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 22
Max :
8 slots available
For 3.5-inch
drive : 2 slots available
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
900GB 10K Hot Plug 2.5-inch SAS HDD
1 x 900 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-482
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1 x 1.2TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-483
300GB 15K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
N8150-485
450GB 15K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
N8150-486
600GB 15K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
N8150-518
SATA HDD (512n)
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-488
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-489
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-527
SAS SSD (eMLC)
200GB Hot Plug 2.5-inch SAS SSD
1 x 200 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
N8150-721
400GB Hot Plug 2.5-inch SAS SSD
1 x 400 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
N8150-722
SATA SSD (ME)
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
N8150-725
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
N8150-726
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
N8150-727
SATA SSD (VE)
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
N8150-732
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
N8150-733
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
N8150-734
1.6TB Hot Plug 2.5-inch SATA SSD
1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
N8150-735
NOTE:
All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs SAS SSDs, SATA SSD (ME), and SATA
SSD (LE) can be mixed.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.
The 2.5-inch SAS/SATA SSDs have limited lifetime. Refer to Endurance of SSD for details.
4.3.4 2.5-inch Drives (4)
Category
Product Name / Description
Part Number
Drive
Standard :4
slots available
Max :
8 slots available
SAS HDD (512n)
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-479
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-480
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-481
900GB 10K Hot Plug 2.5-inch SAS HDD
1 x 900 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-482
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1 x 1.2TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-483
300GB 15K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
N8150-485
450GB 15K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
N8150-486
600GB 15K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
N8150-518
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 23
SAS HDD (512e)
1.8TB 10K Hot Plug 2.5-inch SAS HDD
1x 1.8TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512e sector
N8150-541
SATA HDD (512n)
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-488
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-489
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-527
SAS SSD (eMLC)
200GB Hot Plug 2.5-inch SAS SSD
1 x 200 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
N8150-721
400GB Hot Plug 2.5-inch SAS SSD
1 x 400 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
N8150-722
SATA SSD (ME)
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
N8150-725
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
N8150-726
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
N8150-727
SATA SSD (VE)
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
N8150-732
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector VE
N8150-733
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
N8150-734
1.6TB Hot Plug 2.5-inch SATA SSD
1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
N8150-735
NOTE:
All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs (512n), SAS 10K HDDs (512e), SAS 15K HDDs, SATA HDDs SAS
SSDs, SATA SSD (ME), and SATA SSD (LE) can be mixed.
For 512e sector HDD, the supported operating systems of virtual machines on Hyper-V are:
- Windows Server 2008 R2 SP1 or later
- Windows 7 SP1 or later
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.
The 2.5-inch SAS/SATA SSDs have limited lifetime. Refer to Endurance of SSD for details.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 24
4.3.5 3.5-inch Drives (1)
Category
Product Name / Description
Part Number
Drive
4slots available
SATA HDD
500GB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-524
1TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-504
2TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-505
3TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-506
4TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-507
NOTE:
Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller.
4.3.6 3.5-inch Drives (2)
Category
Product Name / Description
Part Number
Drive
4 slots available
SATA HDD (512n)
500GB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-524
1TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-504
2TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-505
3TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-506
4TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-507
SATA HDD (512e)
6TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 6 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512e sector
N8150-540
8TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 8 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512e Sector
N8150-528
10TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 10 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512e Sector
N8150-543
NOTE:
All drives within a RAID array should be of the same capacity. For 512e sector HDD, the supported operating systems of virtual machines on Hyper-V are:
- Windows Server 2008 R2 SP1 or later
- Windows 7 SP1 or later
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 25
5 Optical Drive
Category
Product Name / Description
Part Number
Internal
1 slot available
Internal Slim DVD-ROM drive
Slim DVD-ROM drive DVD read speed: 8x (DVD-ROM / DVD-R / DVD-RW) CD read speed: 24x (CD-ROM / CD-R/RW)
N8151-134
Internal DVD Super Multi Drive
Slim DVD Super Multi drive, not including writing software DVD Read speed: 8x (DVD-R / DVD-RW / DVD-R DL / DVD+R / DVD+RW / DVD+R DL / DVD-ROM) DVD-RAM read speed: 5x CD read speed: 24x (CD-ROM / CD-R/RW)
NOTE:
- Not supported for Linux or VMware.
N8151-135F
External
External DVD Dual drive
DVD Dual drive, Bus powered, 1.5A required, not including writing software
N8160-101F
NOTE:
An optical drive is required for maintenance and OS installation. Up to 1 optical drive can be connected.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 26
6 PCI Card
Please refer to Supported PCI cards and Installable Slots with regard to the position of PCI slot which can mount PCI card supported.
6.1 Network Interface Controller
Category
Product Name / Description
Part Number
Adapter
GbE
1000BASE-T Adapter
Broadcom ® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x1
N8104-150
Dual Port 1000BASE-T Adapter
Broadcom ® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x1
N8104-151
Quad Port 1000BASE-T Adapter
Broadcom ® BCM5719 Gigabit Ethernet Controller PCIe 2.0 x4
NOTE:
- Network cables with RJ-45 plug covers cannot be used.
N8104-152
10GbE
10GBASE SFP+ Adapter (SFP+/2ch)
Qlogic® NetXtreme II BCM57810 10G SFP+ Dual Port Network Interface Card PCIe 2.0 x8
NOTE:
- N8104-129 SFP+ Module is required to connect with an optical cable.
- Up to two SFP+ Modules can be installed.
- Up to two adapters can be installed.
N8104-149
Dual Port 10GBASE-T Adapter
Intel X550-BT2 PCIe 3.0 x4
N8104-157
SFP+ Module
SFP+ Module (10G-SR)
1 x SFP+ Module for N8104-149
N8104-129
NIC Teaming feature - NIC Teaming and bonding features
See the table below for supported network interfaces and OS combinations. Windows Server 2012 or later and Linux support teaming with bonding function supported by OS.
Network Interface
Team
Operating Systems
1GbE NIC
Embedded 1GbE NIC and N8104-150/-151/-152
Up to four teams per one system Up to four ports per one team
Windows Server 2012 Windows Server 2012 R2 Windows Server 2016 Red Hat Enterprise Linux 7
10GbE NIC
N8104-149
Up to two teams per one system Up to two ports per one team
Windows Server 2012 Windows Server 2012 R2 Windows Server 2016 Red Hat Enterprise Linux 7
10GbE NIC
N8104-157
Up to one teams per one system Up to two ports per one team
Windows Server 2012 Windows Server 2012 R2 Windows Server 2016 Red Hat Enterprise Linux 7
NOTE:
NIC Teaming feature is not supported on iSCSI interfaces. The network interfaces for each teaming must be the same. When 10GbE and 1GbE NIC teams are mixed, the teams must be up to four per one system.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 27
Using iSCSI
See the table below for supported network interfaces and OS combinations.
Category
Network Interface
Operating Systems
1GbE
Embedded 1GbE NIC/ N8104-150/-151/-152
Windows Server 2012, Windows Server 2012 R2, Windows Server 2016, Red Hat Enterprise Linux 7, VMware
10GbE
N8104-149
Windows Server 2012, Windows Server 2012 R2, Windows Server 2016, Red Hat Enterprise Linux 7, VMware
N8104-157
Windows Server 2012, Windows Server 2012 R2, Windows Server 2016, Red Hat Enterprise Linux 7, VMware
NOTE:
NIC Teaming feature is not supported on iSCSI interfaces.
6.2 External Storage Controller
6.2.1 RAID Controller
Category
Product Name / Description
Part Number
Controller
RAID Controller (2GB, RAID0/1/5/6)
Broadcom MegaRAID SAS 9380-8e RAID0/1/5/6/10/50/60, 2GB, Ext. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s, Flash Backup Unit included
N8103-179
NOTE:
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.
It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard
drives failure.
6.2.2 Fibre Channel / SAS Controller
Category
Product Name / Description
Part Number
Fibre Channel
Fibre Channel Controller (1ch)
Emulex LightPulse LPe1250-F8 Host Bus Adapter 8Gb/s, Optical, PCIe 2.0 x8
N8190-159
Fibre Channel Controller (2ch)
Emulex LightPulse LPe12002-M8 Host Bus Adapter 8Gb/s, Optical, PCIe 2.0 x8
N8190-160
Fibre Channel Controller (1ch)
QLogic QLE2690-SR-CK Host Bus Adapter 16Gb/s, Optical, PCIe 3.0 x8
N8190-161
Fibre Channel Controller (2ch)
QLogic QLE2692-SR-CK Host Bus Adapter 16Gb/s, Optical, PCIe 3.0 x8
N8190-162
SAS
SAS Controller
LSI SAS9212-4i4e Host Bus Adapter 6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8
N8103-142
SAS Controller
LSI SAS9300-8e Host Bus Adapter 12Gb/s SAS, ext. 8(SFF-8644 x2), PCIe 3.0 x8
N8103-184
Graphics Accelerator
Product Name / Description
Part Number
Graphics Accelerator
NVIDIA NVS 315, PCI Express 2.0 (x16) 1x DVI-VGA connector, DMS-59-DVI-I branch cable included
N8105-48
NOTE:
The standard VGA connector cannot be used when this option is installed. The remote KVM feature is not supported when this option is installed.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 28
6.4 Serial Port Adapter
Product Name / Description
Part Number
Serial port adapter
Serial port fixed to PCI bracket
N8117-01A
NOTE:
Up to one Serial Port Adapter can be installed.
7 Other Add-in Components
7.1 Cooling Fan Kit
Product Name / Description
Part Number
Non-redundant Fan Kit
Non-hot plug cooling fan for R110i-1
N8181-115F
Redundant Fan Kit
Non-hot plug cooling fan for R110i-1
NOTE:
- The redundant fan kit is necessary to operate the server at temperatures over 40°C with N8181-146F
High temperature resistant Kit
N8181-111F
NOTE:
One of the fan kits must be installed.
7.2 Trusted Platform Module Kit
Product Name / Description
Part Number
Trusted Platform Module Kit
TPM 2.0 module
NOTE:
- Supported for Windows Server 2012 or later only.
N8115-23A
NOTE:
The kit is not available in China. The kit is not removable after attachment. "TPM Support" in BIOS setup menu must be activated prior to use of this kit. To use Windows BitLocker drive encryption, be sure to keep the "recovery password" of BitLocker function. The recovery
password is required to restore data for hardware replacement during a system error.
7.3 Internal Flash Memory
Available socket: 1
Product Name / Description
Part Number
VMware ESXi Base Kit
Internal USB flash memory to install VMware ESXi system
N8106-013
NOTE:
The kit does not include VMware ESXi installation media and license.
7.4 High temperature resistant Kit
Product Name / Description
Part Number
High temperature resistant Kit
Required for high temperature operation over 40°C (up to 45°C)
N8181-146F
NOTE:
Supported for non-hot plug power supply model only. To apply this option, there are some configuration limitations below.
Required System Configuration:
- N8181-111F Redundant Fan Kit is required.
- Up to 3 hard drives.
- Any of N8103-181 (Flash Backup Unit), N8103-179 (RAID Controller (2GB, RAID0/1/5/6)), N8151-134 (Internal Slim DVD-
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 29
ROM drive) or N8151-135F (Internal DVD Super Multi Drive) must not be installed.
7.5 Flash FDD
Choose the Flash FDD if you need to prepare an alternative device for a floppy drive.
Product Name / Description
Part Number
Flash FDD
USB flash emulating USB floppy disk, Native capacity 1.44 MB
N8160-96
NOTE:
Up to one drive can be connected. Not supported when VMware is running on the server.
8 Add-on Components
8.1 17-inch LCD Console Drawer
Category
Product Name / Description
Part Number
Drawer w/ KVM
Drawer
17-inch LCD Console Drawer (8 port)
17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port KVM switch, 1U height
N8143-106F
Cable
Switch Unit Connection Cable Set (USB, 1.8m)
1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A
K410-118(1A)
Switch Unit Connection Cable Set (USB, 3m)
3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A
K410-118(03)
Switch Unit Connection Cable Set (USB, 5m)
5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A
K410-118(05)
Drawer w/o KVM
Drawer
17inch LCD Console Unit 1U
17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height, 4-pin USB B to 4-pin USB A cable 2 m, PS/2 Y-splitter cable 2m, 15­pin mini D-sub VGA cable 2 m
N8143-105F
17inch LCD Console Drawer (1 port)
17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad with 3­button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8 m, Two PS/2 cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m
N8143-108F
Keypad
Keyboard Unit (JP)
JP 108-keys Keyboard with 10-key for N8143-108F 17inch LCD Console Drawer (1 port)
N8143-109
Keyboard Unit (UK)
UK 104-keys Keyboard with 10-key, for N8143-108F 17inch LCD Console Drawer (1 port)
N8143-111
8.2 KVM Switch
Category
Product Name / Description
Part Number
KVM Switch
Server Switch Unit (8 server)
1U USB 8 port KVM switch
N8191-14F
Cable
KVM
Switch Unit Connection Cable Set (USB,1.8m)
1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A
K410-118(1A)
Switch Unit Connection Cable Set (USB,3m)
3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A
K410-118(03)
Switch Unit Connection Cable Set (USB,3m)
5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A
K410-118(05)
Cascading
Switch Unit Connection Cable 1.8 m
1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2
K410-119(1A)
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 30
8.3 Server Management License
The server integrates the EXPRESSSCOPE Engine 3 as standard. Refer to Server Management for the standard management features. For more extensive remote KVM and remote media features, choose the following kit.
Product Name / Description
Part Number
Remote KVM and Media License Kit
License for one server. Remote KVM and remote media are enabled regardless of OS status. Remote KVM:
- Displays a graphics console on the web browser of the remote terminal (PC/server).
- Controls keyboard and mouse via the remote terminals' web browser Remote media:
- Enables the user to use the CD / DVD / FD / Flash memory of the remote terminals (PC/server) as if accessing the local drives.
N8115-04
NOTE:
Remote KVM and remote media features are not available for virtual machines.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 31
References
Boot Mode Setting
The server supports Legacy mode and UEFI mode (default) as an OS Boot Mode. See the table below for the Boot Mode and X2APIC setting for each Operating System. As the default settings at the factory, UEFI mode is set as OS Boot mode and X2APIC is enabled. Refer to the User’s Guide and change the settings before installing an Operating System requiring Legacy Mode.
Operating System
Supported Boot Mode
Supported X2APIC Setting
Windows Server 2012
UEFI
Enabled
Windows Server 2012 R2
UEFI
Enabled
Windows Server 2016
UEFI
Enabled
Red Hat Enterprise Linux 7
UEFI
Enabled
VMware ESXi 6.0
UEFI
Enabled
VMware ESXi 6.5
UEFI
Enabled
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 32
Server Management
The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system management features listed in the table below.
Standard
With Remote KVM and Media License kit
Hardware monitoring
Temperature/fan/voltage/power consumption/System FAN/degeneration(memory)


Hardware configuration information collection


Hardware event log collection


Boot monitoring
BIOS/POST stall, Booting, OS stall, shutdown
2
2
Alerting
HW error, Boot error and OS panic (by SNMP, E-Mail)


Remote KVM (via LAN)
POST/BIOS setup, ROM utility
1

Panic screen, Boot screen
1,3

CUI-based screen (OS console)
1,4

GUI-based screen (OS console)
-

Remote KVM Video Record
-

Remote control (via LAN)
Remote reset/power on-off/ dump


Remote Power Capping


BIOS/BMC FW update


Remote BIOS setup(partial configuration only)


OS shutdown
2
2
Remote media (CD/DVD/FD/USB)
-

CLP (Command Line Protocol) (DMTF compliant)


Remote control via Web browser (multi user login at the same time)


Scheduling (without UPS, require NEC ESMPRO Manager)
2
2
BIOS setting by using XML file


Maintenance
EXPRESSSCOPE® Profile key (Backup/restore BIOS/BMC setup information)


Others
Set automatic IP address via DNS/DHCP


LDAP/Active Directory verification/user control


Clock synchronization of main unit and the RTC


Access log collection


Industry Standard
IPMI support
2.0
2.0
1
The optional serial port is not available for the feature.
2
The feature is not supported on VMware ESXi systems.
3
Monitoring boot screens is not supported on VMware systems.
4
In VMware systems, only the direct console user interface is supported.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 33
Endurance of SSD
The 2.5-inch SAS/SATA SSDs have limited lifetime, which can only be written a limited number of times before it fails. The warranty period of SSD is the stated period of warranty or until the total bytes of written value (PBW) exceeds the limit value,
whichever occurs first. It is recommended to check the total bytes of written value periodically.
Refer to the table below for the write endurance (PBW and DWPD), warranty period and monitoring tool.
SSD Lifetime
Part Number
Product Name
PBW
DWPD
Period
SAS SSD
N8150-721
200GB Hot Plug 2.5-inch SAS SSD
3.6PBW
10 Times
3 Years
N8150-722
400GB Hot Plug 2.5-inch SAS SSD
7.3PBW
10 Times
3 Years
SATA SSD (Middle Endurance)
N8150-725
200GB Hot Plug 2.5-inch SATA SSD
3.6PBW
10 Times
3 Years
N8150-726
400GB Hot Plug 2.5-inch SATA SSD
7.3PBW
10 Times
3 Years
N8150-727
800GB Hot Plug 2.5-inch SATA SSD
14.6PBW
10 Times
3 Years
SATA SSD (Value Endurance)
N8150-732
200GB Hot Plug 2.5-inch SATA SSD
1.1PBW
3 Times
3 Years
N8150-733
400GB Hot Plug 2.5-inch SATA SSD
3.0PBW
3 Times
3 Years
N8150-734
800GB Hot Plug 2.5-inch SATA SSD
5.3PBW
3 Times
3 Years
N8150-735
1.6TB Hot Plug 2.5-inch SATA SSD
10.7PBW
3 Times
3 Years
PBW(Peta-Bytes Write): Total amount of data that can be written into the SSD. 1PB=1,000TB. DWPD(Drive Writes per Day): Rewrite capacity of the SSD per day. Check the lifetime of SSD by monitoring tool regularly. It is recommended to replace the SSD before it reaches its end of life. For repurchase, please contact your sales representative. For detailed operating methods of monitoring tool, refer to the Users Guide.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 34
OS Support Matrix for PCI Cards and Embedded Controllers
Part Number
Product Name
WS 2016 WS 2012 R2 WS 2012 RHEL 7 ESXi 6.0 ESXi 5.5
-
Embedded SATA non-RAID Controller


-
Embedded SATA RAID Controller

- - - - Embedded 1GbE NIC


N8103-188
RAID controller (RAID0/1)


N8103-176
RAID Controller (1GB, RAID 0/1)


N8103-177
RAID Controller (1GB, RAID 0/1/5/6)


N8103-178
RAID Controller (2GB, RAID 0/1/5/6)


N8105-48
Graphics Accelerator

- - -
N8190-162
Fibre Channel Controller (2ch)


N8190-161
Fibre Channel Controller (1ch)


N8103-179
RAID Controller (2GB, RAID0/1/5/6)


N8103-184
SAS Controller
-

N8104-157
Dual Port 10GBASE-T Adapter


N8104-149
10GBASE SFP+ Adapter (SFP+/2ch)


N8190-160
Fibre Channel Controller (2ch)


N8190-159
Fibre Channel Controller (1ch)


N8103-142
SAS Controller


N8104-152
Quad Port 1000BASE-T Adapter


N8104-151
Dual Port 1000BASE-T Adapter


N8104-150
1000BASE-T Adapter


SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 35
Supported PCI cards and Installable Slots
Slots
Part Number
Product Name
1A
1B
1C
N8103-188
RAID controller (RAID0/1)
(1) - -
N8103-176
RAID Controller (1GB, RAID 0/1)
(1) - -
N8103-177
RAID Controller (1GB, RAID 0/1/5/6)
(1) - -
N8103-178
RAID Controller (2GB, RAID 0/1/5/6)
(1) - -
N8105-48
Graphics Accelerator
-
(1)
-
N8190-162
Fibre Channel Controller (2ch)
-
(1) - N8190-161
Fibre Channel Controller (1ch)
-
(1)
(2)
N8103-179
RAID Controller (2GB, RAID0/1/5/6)
-
(1)
(2)
N8103-184
SAS Controller
-
(1)
(2)
N8104-157
Dual Port 10GBASE-T Adapter
-
(1)
(2)
N8104-149
10GBASE SFP+ Adapter (SFP+/2ch)
-
(1)
(2)
N8190-160
Fibre Channel Controller (2ch)
-
(1)
(2)
N8190-159
Fibre Channel Controller (1ch)
-
(1)
(2)
N8103-142
SAS Controller
-
(1)
(2)
N8104-152
Quad Port 1000BASE-T Adapter
- - (1)
N8104-151
Dual Port 1000BASE-T Adapter
-
(1)
(2)
N8104-150
1000BASE-T Adapter
-
(1)
(2)
N8118-307
Dual M.2 SATA Installation Kit
- - (1)
N8117-01A
Serial port adapter
-
(1)
(2)
The number between parentheses shows the population priority (recommendation). For example, install N8103-176 in the slot
#1 and N8104-152 in the slot #2 when you have those cards.
There are PCI slot limitations depending on the processor and operating system. Please refer to the next page and be careful to
choose a processor and PCI cards.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 36
PCI slot limitations for VMware
Do not install N8104-152 Quad Port 1000BASE-T Adapter when any of the following cards is installed.
- N8104-157 Dual Port 10GBASE-T Adapter
- N8104-149 10GBASE SFP+ Adapter (SFP+/2ch)
For the configuration limitation for VMware ESXi, refer to the following documents.
- VMware ESXi6.0
https://www.vmware.com/pdf/vsphere6/r60/vsphere-60-configuration-maximums.pdf
- VMware ESXi6.5
https://www.vmware.com/pdf/vsphere6/r65/vsphere-65-configuration-maximums.pdf
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 37
Secure Boot Mode
This server supports Secure Boot. It is supported with UEFI Boot mode and protects the security by only allowing software programs with digital signature to run. The supported operating systems, software, and boot devices are below. The default setting of Secure Boot is disabled. Keep the setting disabled to use other operating systems and/or software.
Supported OS and Software for Secure Boot Mode
Operating System
Supported Boot Mode
Secure Boot Mode
Windows Server 2012
UEFI
Windows Server 2012 R2
UEFI
Windows Server 2016
UEFI
Software Related to Boot
Supported Boot Mode
Secure Boot Mode
System Diagnostics Utility
UEFI  EXPRESSBUILDER
UEFI
Supported Boot Device for Secure Boot Mode
Supported Boot Device
Part Number
RAID controller (RAID0/1)
N8103-188
RAID controller (1GB, RAID0/1)
N8103-176
RAID controller (1GB, RAID0/1/5/6)
N8103-177
RAID controller (2GB, RAID0/1/5/6)
N8103-178
RAID controller (2GB, RAID0/1/5/6)
N8103-179
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 38
Copyright Notice and Liability Disclaimer
The information contained herein is subject to change without notice. Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or
other countries Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other
countries. Linux is a trademark of Linus Torvalds. Red Hat is a registered trademark of Red Hat, Inc. in the U.S. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective
holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/R110i-1
NEC Corporation Revision 2.0 – June, 2017 39
Revision History
Revision
Date
Description
2.0
June 6, 2017
New products added:
120GB M.2 SATA SSD / N8150-736 Dual M.2 SATA Drive Installation Kit / N8118-307 Graphics Accelerator / N8105-48
Others:
Removed support information related to Windows Server 2008 R2
1.0
April 19, 2017
Initial release
Loading...