Installation and Assembly - Universal Ceiling Mount
Model: NP01UCM
Maximum Load Capacity: 50 lb (22.7 kg)
Read instruction sheet before you start inst allation and assembly.
WARNING
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
IMPORT ANT! Be sure not to touch the projector while tightening the set screw on the ball and socket mount. This may cause the image to be unaligned when you let go.
IMPORT ANT! T urn to the appropriate page for your ceiling inst allation.
Flush Mount.................................................................................................................................................. page 7
Extension Column........................................................................................................................................ page 8
Installations:
To Wood Joist Finished Ceilings,
Exposed Wood Joists, or Wood Beam Ceilings........................................................................................ page 5
T o Concrete Ceilings.................................................................................................................................... page 6
Visit the NEC Web Site at www.necsam.com
1 of 9
ISSUED: 04-11-06 SHEET #: 055-9458-2 05-09-06
For customer care call 1-800-729-0307 or 708-865-8870.
Page 2
Compatability Chart for NEC Projectors
Manufacturer Model Manufacturer Model
NEC HT410 NEC MT1035 NEC HT510 NEC MT1035+ NEC GT1150 NEC MT830 NEC GT2150 NEC MT830+ NEC GT5000 NEC MT1040 NEC GT6000 NEC MT1045 NEC GT6000R NEC MT840 NEC GT2000 NEC MT850 NEC GT2000R NEC MT1050 NEC GT950 NEC MT1055 NEC LT10 NEC MT1056 NEC LT140 NEC MT860 NEC LT84 NEC MT1060 NEC LT150 NEC MT1060R NEC LT150z NEC MT1065
NEC LT75 NEC Multisync LT245 NEC LT75z NEC NP1000
NEC LT85 NEC NP2000 NEC LT154 NEC V37 NEC LT155 NEC LT380 NEC LT156 NEC VT440 NEC LT157 NEC VT440K NEC LT158 NEC VT540 NEC LT170 NEC VT540K NEC LT180 NEC VT650 NEC LT220 NEC VT45 NEC LT240 NEC VT45K NEC LT240K NEC VT46 NEC LT245 NEC VT460 NEC LT260 NEC VT465 NEC LT260K NEC V47 NEC LT265 NEC VT560 NEC LT280 NEC VT660 NEC LT35 NEC VT660K NEC HT1000 NEC VT770 NEC HT1100 NEC VT47 NEC MT1000 NEC VT470 NEC MT1020 NEC VT480 NEC MT810 NEC VT48 NEC MT820 NEC VT570 NEC MT1030 NEC VT575 NEC MT1030+ NEC VT580
NEC VT670 NEC VT676 NEC WT600
Visit the NEC Web Site at www.necsam.com
2 of 9
ISSUED: 04-11-06 SHEET #: 055-9458-1
For customer care call 1-800-729-0307 or 708-865-8870.
Page 3
Before you start check the parts list to insure all of the parts shown are included.
Parts List
Description Qty. Part Number
A ball and socket mount 1 055-0016 B 4 mm security allen wrench 1 560-9646 C M5 x .8 x 10 mm socket pin type F screw 1 520-2031 D #10-32 x 3/8" spade thumb screw 1 560-2107 E #10-32 x 3/8" serrated washer head socket pin screw 1 520-2151 F #14 x 2.5 phillips hex head wood screw 2 5S1-015-C04 G ceiling plate 1 580-4042 H .25" ID x .56" OD x .26 spacer 2 590-2071 I extension column connector with cord management 1 580-4025 J #10-32 x 3/8" socket pin screw 2 520-2084 K #10-32 x 3/16" slotted set screw 3 520-2187 L adapter plate 1 055-0614 M M3 x 8 mm serrated washer head socket pin screw (not shown) 4 510-2004 N M4 x 10 mm serrated washer head socket pin screw (not shown) 4 510-2060 O M5 x 10 mm serrated washer head socket pin screw (not shown) 4 510-2063 P M6 x 10 mm serrated washer head socket pin screw (not shown) 4 510-2066 Q 2 mm security allen wrench 1 560-1097 R washer 4 540-2025
A
I
L
Note: Actual parts may appear slightly different than illustrated.
G
C
J
D
R
K
B
FASTENERS
E
H
F
Q
Visit the NEC Web Site at www.necsam.com
3 of 9
ISSUED: 04-11-06 SHEET #: 055-9458-2 05-09-06
For customer care call 1-800-729-0307 or 708-865-8870.
Page 4
Installation and assembly - Universal Adapter Plate
Note: The projector you are installing may differ in appearance from the sample illustrated below. Place projector upside down. Locate adapter plate (L) with notch facing forward as close to projector center of
gravity as possible without covering any mounting holes. Loosen channels, and if there are only three mounting holes remove fourth channel. Using one channel for each mounting hole, position feet of channels over mounting holes as shown below. Important: If projector does not have at least three mounting holes, do not use this adapter plate. Note: Some projectors have feet which can be removed and the corresponding threaded insert can be used for a mounting hole. Note: Once channels are in position retighten fasteners. *Notch indicates front of projector.
Mounting hole
L
*
Generic Projector
Attach adapter plate (L) to projector using one screw (M, N, O, or P) for each channel as shown below. T ighten all screws, while keeping the center of gravity . Be sure that adapter plate (L) is straight. Adjust the feet of the channels to keep the adapter plate level. Tighten all screws with 4 mm security allen wrench (B) or wrench provided with projector mount, while keeping the center of gravity . If M3 screws are used, tighten using 2 mm security allen wrench (Q). Note: Projectors will require different size screws for mounting. Use a combination of screws (M, N, O, or P) and foot adjustment that will result in channels of adapter plate (L) fitting tightly against projector . Important: In order to properly engage the threads in the mounting holes, the screw must be turned at least 3 full turns. Note: If using screw (M), place washer (R) between screw (M) and foot of channel.
CAUTION
• It is the responsibility of the installer to ensure that the projector is properly ventilated. Feet of channels are used to raise the mount off the projector surface.
L
Generic Screw
Foot of Channel
Visit the NEC Web Site at www.necsam.com
4 of 9
ISSUED: 04-11-06 SHEET #: 055-9458-1
For customer care call 1-800-729-0307 or 708-865-8870.
Page 5
Installation To Wood Joist Finished Ceilings, Exposed Wood Joists, or Wood Beam Ceilings
Drill two 5/32" (4 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach ceiling plate (G) with two #14 x 2.5" (6 mm x 65 mm) wood screws (F) as shown using 3/8" (10 mm) socket wrench.
Skip to step 2.
WOOD JOIST
WARNING
• Tighten wood screws (F) so that wall plate (G) is firmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
• Never tighten in excess of 80 in • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the studs. The use of an "edge to edge" stud finder is highly recommended.
WARNING
• It is the responsibility of the installer to verify that the supporting surface will safely support the combined load of all attached hardware and components.
IMPORTANT: Be sure to drill holes into the joist CENTER!
CEILING
G
F
F
WOOD JOIST
CEILING
H
F
Visit the NEC Web Site at www.necsam.com
F
H
G
5 of 9
For optional Cord Management,
install two spacers (H) between ceiling plate (G) and ceiling.
ISSUED: 04-11-06 SHEET #: 055-9458-2 05-09-06
For customer care call 1-800-729-0307 or 708-865-8870.
Page 6
WARNING
• When installing wall mounts on concrete, verify that you have a minimum of 1 5/8" of actual concrete surface in the 1/ 4" diameter hole to be used for the concrete anchors. Do not drill into mortar joints! Concrete must meet ASTM C-90 specifications.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor .
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard­ware and components.
• Never exceed the Maximum Load Capacity of 50 lb (22.7 kg).
Installation to Concrete Ceilings
ACC 203 (Alligator® concrete anchors) are recommended.
Drill two 1/4" (6 mm) dia. holes to a minimum depth of
2.5" (64 mm). Attach ceiling plate (G) using two concrete anchors and #14 x 2.5" wood screws (F) as shown in Illustration A and 1, 2, and 3 (below). Tighten all fasteners.
IMPORTANT: It is the responsibility of the installer to verify that the ceiling will safely support the combined load of all attached hardware and components.
concrete anchor
CONCRETE CEILING
WARNING
• Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
• Never tighten in excess of 80 in • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the studs. The use of an "edge to edge" stud finder is highly recommended.
1
Drill hole and insert anchor
2
G F
Place ceiling plate over anchor and secure with screw
3
concrete ceiling
concrete anchor
concrete anchor
G
F
Illustration A
WARNING
FOR DIRECT AT TACHMENT T O LOAD BEARING CONCRETE ONL Y! Concrete expansion anchors are not intended for attachment to concrete ceilings
covered with a layer of plaster, drywall, or other finishing material. If mounting to concrete ceiling covered with plaster / drywall is unavoidable, plaster / drywall must be counterbored as shown below.
metal bracket
INCORRECT
concrete
metal bracket
CORRECT
concrete
concrete
F
After repeating step one tighten all fasteners
Visit the NEC Web Site at www.necsam.com
anchor
6 of 9
CUT AW A Y VIEW
plaster/ dry wall
ISSUED: 04-11-06 SHEET #: 055-9458-1
For customer care call 1-800-729-0307 or 708-865-8870.
plaster/ dry wall
Page 7
Flush Mount Application
Screw ball and socket mount (A) into ceiling plate (G). Align the notch with one of the four holes of the ceiling plate (G) and secure ball and socket mount (A) with a M5 x 10 mm socket pin screw (C) using security allen wrench (B) as shown in detail 1. Note: Slotted set screw (K) is used to jam against the threads of the ball and socket mount to prevent any excess
movement of the ball and socket mount (A). Do not overtighten screw; overtightening screw will damage threads making it difficult to separate the products.
Skip to step 3.
K
NOTCH
CEILING
WOOD
G
A
C
A
G
DETAIL 1
Visit the NEC Web Site at www.necsam.com
7 of 9
ISSUED: 04-11-06 SHEET #: 055-9458-2 05-09-06
For customer care call 1-800-729-0307 or 708-865-8870.
Page 8
Installation to Extension Column
G
C
K
Screw extension column to ceiling plate (G). Align the notch with one of the four holes in the ceiling plate (G) and secure extension column with a M5 x 10 mm socket pin screw (C) using security allen wrench (B).
See detail 4.
Screw extension column connector (I) to extension column. Align slot in extension column with one of the top holes in extension column connector (I). Insert and tighten one #10-32 x 3/8" socket pin screw (J) through extension column connector (I) into slot on extension column using security allen wrench (B). See detail 5.
Screw ball and socket mount (A) to extension column connector (I). Align slot in ball and socket mount (A) to one of the bottom holes in extension column connector (I). Insert and tighten one #10-32 x 3/8" socket pin screw (J) through extension column connector into slot in ball and socket mount (A) using security allen wrench (B). See detail 6.
EXTENSION COLUMN (UL Listed EXT or ADJ Series) Sold Separately
SLOT
I
SLOT
EXTENSION COLUMN
K
I
G
EXTENSION COLUMN
DETAIL 4
SLOT
J
Note: Slotted set screws (K) are used to
jam against the threads of each connecting joint to prevent any excess movement. Do not overtighten screws; overtightening screws will damage threads making it difficult to separate the products.
A
A
I
K
DETAIL 5
EXTENSION COLUMN
SLOT
J
DETAIL 6
Visit the NEC Web Site at www.necsam.com
8 of 9
ISSUED: 04-11-06 SHEET #: 055-9458-1
For customer care call 1-800-729-0307 or 708-865-8870.
Page 9
Note: The projector adapter plate and projector you are installing may differ in appearance from the sample illustrated below.
Attach projector, with adapter plate already on it, to the ball and socket mount (A) by inserting the ball and socket mount (A) into the adapter plate connection and twisting until the adapter plate will no longer turn (about 75°). The spring loaded captive screw should line up with a corresponding hole on the adapter plate (this should line up automatically when the two are connected). Push down and tighten the spring loaded captive screw to secure the adapter plate to the mount. If not using the optional security feature, fasten thumb screw (D) in the hole opposite the spring loaded captive screw.
OPTIONAL: For security, insert serrated washer head socket pin security screw (E) in the hole opposite the spring loaded captive screw. Tighten with security allen wrench (B). This will prevent the projector from being removed.
Note: Be sure to only use the #10-32 x 3/8" screw (E) (or the thumb screw (D)) opposite the spring loaded captive screw.
CUTA W AY VIEW OF CEILING PLATE ( G)
CEILING
E
WOOD JOIST
D
To adjust roll, pitch, and yaw loosen the set screw (shown below) using security allen wrench (B) or standard 4 mm allen wrench. You should be able to just slightly loosen the screw so that your adjustments can be set without having to hold the projector. Move projector to desired position and slowly tighten set screw.
Note: Be sure not to touch the projector while tightening the set screw. This may cause the image to be unaligned when you let go.
IMPORTANT: Allen wrench is your key for projector removal. Store it in a safe place.
WOOD JOIST
CEILING
SET SCREW
A
CAPTIVE
SCREW
2
1
PROJECTOR ADAPTER PLA TE
PROJECTOR
WARNING
• Do not lift more weight than you can handle! Use additional man power or mechanical lifting equipment to safely handle placement of the projector!
PROJECTOR
Visit the NEC Web Site at www.necsam.com
9 of 9
ISSUED: 04-11-06 SHEET #: 055-9458-2 05-09-06
For customer care call 1-800-729-0307 or 708-865-8870.
Loading...