NEC NP-ME402X Installation Guide

NEC Display Solutions of America, Inc.
MC372X/ME402X Installation Guide
Ceiling Mounted and Desktop Rev 1.0
Product Description, Lens Specs, Notes and Formulas Pg 1 Diagrams & Distance Charts Pg 2-3 Cabinet Dimensions Pg 4-5 Ceiling Mount Dimensions Pg 6 Input Panel and Control Codes Pg 7
Product Description
Type : 3 panel LCD Projector Dimensions: 13.6” (W) x 4.1” (H) x 10.3” (D)
0.63” p-Si TFT w/MLA Weight: 7.1 lbs Resolution: 1024 x 768
Fan Noise: 37dB / 29dB @ 1 meter Brightness: MC372X: 3700 Lumens
ME402X: 4000 Lumens
Power Consumption: MC372X: 267W (max) BTU’s: MC372X: TBD BTU/hour ME402X: 288W (max) ME402X: TBD BTU/hour
Lens Specifications
Throw Ratio: MC372X: 1.5 – 1.8:1 (for 100” diagonal) Focal Length: MC372X: 19.2mm – 23.0mm
ME402X: 1.3 – 2.2:1 (for 100” diagonal) ME402X: 17.4mm – 29.0mm
Offset Angle: MC372X: 6.6° - 10.9° (for 100” diagonal) F/#: MC372X: 1.6 - 1.76 ME402X: 6.6° - 10.9° (for 100” diagonal) ME402X: 1.7 - 2.2
Screen Sizes: 30” - 300” diagonal (4:3) Manual Focus/Manual Zoom
For screen sizes not indicated on the projection tables, use the formulas below.
If the figures on the tables do not match the results of formulas, use the figures in the table.
All calculations are based on a 4:3 aspect ratio.
Distances are in inches, for millimeters multiply by 25.4.
Distances may vary ±5%.
The Projection Formulas use the image width for calculation. For proper projection placement, determine the image width for the desired screen size. Use the Screen Formulas below to calculate all screen dimensions. Plug in the width for “W” in the Projection Formulas. Refer to the diagrams and charts for popular screen sizes on page 2:
Definitions:
W = Image Width H = Image Height (size) B = Vertical distance between lens center and screen center C = Throw distance D = Vertical distance between lens center and screen top (screen bottom for desktop application)
www.necdisplay.com MC372X/ME402X Page 1 of 6
MC372X/ME402X Installation Guide
Diagonal Width (W) Height (H)
inches inches inches inches
57 46 34 12 68 - 82 10.2 - 8.5
66 53 40 14 79 - 95 10.2 - 8.5
68 54 41 15 81 - 98 10.2 - 8.5
75 60 45 16 90 - 108 10.2 - 8.5
79 63 47 17 95 - 114 10.2 - 8.5
85 68 51 18 102 - 122 10.2 - 8.5
92 74 55 20 110 - 132 10.2 - 8.5
98 78 59 21 117 - 141 10.2 - 8.5
102 82 61 22 122 - 147 10.2 - 8.5
111 89 67 24 133 - 160 10.2 - 8.5
113 90 68 24 135 - 162 10.2 - 8.5
123 98 74 26 147 - 177 10.2 - 8.5
125 100 75 27 150 - 180 10.2 - 8.5
147 118 88 32 176 - 211 10.2 - 8.5
149 119 89 32 178 - 214 10.2 - 8.5
213 170 128 46 255 - 306 10.2 - 8.5
255 204 153 55 305 - 367 10.2 - 8.5
Screen Size ( 4:3)
-5
inches
B
C
w ide - tele
inches
-13
degrees
D
α
w ide - tele
-6
-6
-7
-7
-7
-8
-9
-9
-13
-19
-22
-10
-10
-11
-11
B
C
Lens Ctr
Screen Ctr
Throw D istanc e
Screen Bottom
2.30"
C
Throw D istanc e
Screen Top
Lens Offset From Mount Pipe
D
B
Lens Ctr
Screen Ctr
D
5.43
5.56
2.55
Ceiling Mounted and Desktop Rev 1.0

Diagrams and Distance Charts for MC372X

The following shows the proper relative positions of the projector and screen. Refer to the table to determine the position of installation. Distances are in inches. For millimeters multiply by 25.4.
Ceiling Mounted
Desktop
Distance Chart for popular 4:3 screens
4:3 Screen Formulas:
W = Image Width = H x 4/3 W = H x 4/3 H = Image Height = W x 3/4 H = W x 3/4 Screen Diagonal = W x 5/4
Projection Formulas: B = 0.268W C (wide) = 1.47W – 0.08 C (tele) = 1.798W – 0.1 D = -0.11W
α (wide) = tanˉ¹ (B/C(wide)) α (tele) = tanˉ¹ (B/C(tele))
For screen sizes not indicated on the projection
Note:
tables, use the formulas on page 1.
www.necdisplay.com MC372X/ME402X Page 2 of 6
NEC Display Solutions of America, Inc.
MC372X/ME402X Installation Guide
Diagonal Width (W) Height (H)
inches inches inc hes inc hes
57 46 34 12 61 - 102 11.0 - 6.6
66 53 40 14 70 - 118 10.9 - 6.6
68 54 41 14 73 - 122 10.9 - 6.6
75 60 45 15 80 - 134 10.9 - 6.6
79 63 47 16 85 - 142 10.9 - 6.6
85 68 51 18 91 - 152 10.9 - 6.6
92 74 55 19 99 - 165 10.9 - 6.6
98 78 59 20 105 - 176 10.9 - 6.6
102 82 61 21 110 - 183 10.9 - 6.6
111 89 67 23 120 - 200 10.8 - 6.5
113 90 68 23 122 - 203 10.8 - 6.5
123 98 74 25 133 - 221 10.8 - 6.5
125 100 75 26 135 - 225 10.8 - 6.5
147 118 88 30 159 - 265 10.8 - 6.5
149 119 89 31 161 - 269 10.8 - 6.5
213 170 128 44 231 - 385 10.8 - 6.5
255 204 153 53 277 - 461 10.7 - 6.5
-8
-8
-12
-17
-20
-9-9-10
-10
-5-5-6
-6
-7
-7
-12
degrees
D
α
w ide - tele
Screen Size ( 4:3)
-5
inches
B
C
w ide - tele
inches
B
C
Lens Ctr
Screen Ctr
Throw D istanc e
Screen Bottom
2.30"
C
Throw D istanc e
Screen Top
Lens Offset From Mount Pipe
D
B
Lens Ctr
Screen Ctr
D
5.43
5.56
2
.55
Ceiling Mounted and Desktop Rev 1.0

Diagrams and Distance Charts for ME402X

The following shows the proper relative positions of the projector and screen. Refer to the table to determine the position of installation. Distances are in inches. For millimeters multiply by 25.4.
Ceiling Mounted
Desktop
Distance Chart for popular 4:3 screens
4:3 Screen Formulas:
W = Image Width = H x 4/3 W = H x 4/3 H = Image Height = W x 3/4 H = W x 3/4 Screen Diagonal = W x 5/4
Projection Formulas: B = 0.258W C (wide) = 1.368W – 1.82 C (tele) = 2.269W – 1.82 D = -0.10W
α (wide) = tanˉ¹ (B/C(wide)) α (tele) = tanˉ¹ (B/C(tele))
For screen sizes not indicated on the projection
Note:
tables, use the formulas on page 1.
www.necdisplay.com MC372X/ME402X Page 3 of 6
NEC Display Solutions of America, Inc.
3.7
2.1
3.1
2.3
13.6
10.3
11.2
4.1
4.5
LAMP
INTAKE
EXHAUST
NEC Display Solutions of America, Inc.
MC372X/ME402X Installation Guide
Ceiling Mounted and Desktop Rev 1.0

Cabinet Dimensions

The following drawings show the cabinet dimensions. Dimensions are in inches. For millimeters multiply by 25.4.
www.necdisplay.com MC372X/ME402X Page 4 of 6
6.9
0.2
6.1
5
7.7
5.5
5.5
FOR CEILING MOUNT
5-M4 (Max.M4x10)
NEC Display Solutions of America, Inc.
MC372X/ME402X Installation Guide
Ceiling Mounted and Desktop Rev 1.0

Cabinet Dimensions (continued)

The following drawings show the cabinet dimensions. Dimensions are in inches. For millimeters multiply by 25.4.
www.necdisplay.com MC372X/ME402X Page 5 of 6
NEC Display Solutions of America, Inc.
MC372X/ME402X Installation Guide
Ceiling Mounted and Desktop Rev 1.0

Optional Ceiling Mount Dimensions (Model #: MP300CM)

The following drawings show the ceiling mount dimensions. Dimensions are in inches. For millimeters multiply by 25.4.
www.necdisplay.com MC372X/ME402X Page 6 of 6
1 2
3 4
5
6 7 8
9
To GND of PC
To RxD of PC
To TxD of PC
To CTS of PC
To RTS of PC
NEC Display Solutions of America, Inc.
MC372X/ME402X Installation Guide
Ceiling Mounted and Desktop Rev 1.0

Input / Output Panel

PC Control Codes

Function Code Data

POWER ON 02H 00H 00H 00H 00H 02H POWER OFF 02H 01H 00H 00H 00H 03H INPUT SELECT COMPUTER1 02H 03H 00H 00H 02H 01H 01H 09H INPUT SELECT HDMI 1 02H 03H 00H 00H 02H 01H 1AH 22H INPUT SELECT HDMI 2 02H 03H 00H 00H 02H 01H 1BH 23H INPUT SELECT VIDEO 02H 03H 00H 00H 02H 01H 06H 0EH INPUT SELECT VIEWER (USB-A) 02H 03H 00H 00H 02H 01H 1FH 27H INPUT SELECT NETWORK 02H 03H 00H 00H 02H 01H 20H 28H INPUT SELECT USB DISPLAY (USB-B) 02H 03H 00H 00H 02H 01H 22H 2AH PICTURE MUTE ON 02H 10H 00H 00H 00H 12H PICTURE MUTE OFF 02H 11H 00H 00H 00H 13H SOUND MUTE ON 02H 12H 00H 00H 00H 14H SOUND MUTE OFF 02H 13H 00H 00H 00H 15H PROJECTOR INFORMATION REQUEST 00H BFH 00H 00H 01H 02H C2H ERROR STATUS REQUEST 00H 88H 00H 00H 00H 88H INFORMATION REQUEST 03H 8AH 00H 00H 00H 8DH

Note: Contact your NEC rep for codes not listed.

Cable Connection
Communication Protocol:
Baud Rate: 38400 bps Data Length: 8 bits Parity: No Parity Stop Bit: One Bit X on/off: None Communications: Full duplex
PC Control Connector (D-Sub 9P)
NOTE 1 : Pins 1, 4, 6, and 9 are used inside the projector. NOTE 2: For long cable runs it is recommended to set communication speed within the projector to 9600 bps. NOTE 3: Jumper “Request to Send” and “Clear to Send” together on both ends of the cable to simplify cable connection.
www.necdisplay.com MC372X/ME402X Page 7 of 6