NEC I755 DECT Specifications

1
NEC Australia
nec.com.au
Specifications
I755 DECT Handset
Robust handset for voice and messaging in demanding environments.
The DECT handset I755 is designed for use in potentially demanding environments, such as healthcare, manufacturing, retail and warehousing.
Physical characteristics
Dimensions
Handset 127x46x22 mm
Charger 93x80x70 mm
Charger Rack 545x108x85 mm
Weight
Handset 120 g
Charger 137g
AC Adaptor 94 g
Protection
Handset IP54
Range
Indoor 50 m max
1)
Outdoor 300 m max
1)
Power Supply
Handset 3.7V, 650mAh Lithium-ion battery
Charger Powered via AC/DC adapter
Input
•
100-240VAC/50/60Hz/250mA
Output
•
12VDC/400mA
Mains plug
•
Euro, UK, North America or Australia
2)
Charger rack Powered via AC/DC adapter
Input
•
100-240VAC/50/60Hz/500 mA
Output
•
12 VDC/2500mA
Mains plug
•
Euro, UK, North America or Australia
2)
Status line indicators
User selectable status line indicators in the display are:
Battery condition
•
Caller lter active
•
Field strength
•
Key lock active
•
Loudspeaker active
•
Message waiting
•
Microphone mute
•
Missed Call
•
Ringer off
•
Supported menu languages
The handset supports 14 selectable languages: Danish, Dutch, English, French, German, Greek, Italian, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, Turkish
Colour and finishing
Handset:
Light grey with dark grey protective rim
•
Desktop charger and charger rack:
Light grey (front) and dark grey (back)
•
1) The radio coverage of DECT handsets depend on the environment and presence of obstacles.
2) The mains plug contains a changeable part for the different power plugs
LED indicators
Three of the following user selectable indicators can be assigned to the tricolour indicator LED:
Battery low
•
Man down
•
Misses call
•
Text message
•
Text or voice message
•
Voice message
•
Audible indicators
The following selectable audible indicators are available:
Key click
•
Coverage warning
•
Charger warning
•
Battery low alarm
•
Conrmation tone
•
2
I755 DECT Handset
UNIVERGE®360 is NEC’s approach to unifying business communications. It places people at the centre of communications and delivers on an organisation’s needs by uniting infrastructure, communications and business.
Corporate Headquarters (Japan)
NEC Corporation
www.nec.com
Oceania (Australia)
NEC Australia Pty Ltd
www.nec.com.au
North America (USA)
NEC Corporation of America
www.necam.com
Asia
NEC Corporation
www.nec.com
Europe (EMEA)
NEC Philips Unified Solutions
www.nec-philips.com
About NEC Australia Pty Ltd. NEC Australia is a leading supplier and integrator of ICT solutions to carriers, government and businesses. With
over 800 staff and over 200 partner organisations, we research, develop and deploy advanced IT/Network communication solutions and services using best-of-breed technologies in multi-vendor environments. Our business encompasses Hosted Application and Network Services, Systems Integration, IP Communications Servers, PBX, Broadband Access Systems, Data Centre and Cloud Technology Services along with Digital Signage and Data Technology products.
I755 DECT Handset | v. 19.04.2010
NEC Australia Pty Ltd reserves the right to change product specifications, functions, or features, at any time, without notice. Please refer to your local NEC representatives for further details. Although all efforts have been made to ensure that the contents are correct, NEC shall not be liable for any direct, indirect, consequential or incidental damages resulting from the use of the equipment, manual or any related materials. The information contained herein is the property of NEC Australia Pty Ltd and shall not be reproduced without prior written approval from NEC Australia Pty Ltd.
Copyright© 2010 NEC Australia Pty Ltd. All rights reserved. NEC, NEC logo, and UNIVERGE are trademarks or registered trademarks of NEC Corporation that may be registered in Japan and other jurisdictions. All other trademarks are the property of their respective owners. All rights reserved. Printed in Australia. Note: This disclaimer also applies to all related documents previously published.
For more information, visit www.nec.com.au, email contactus@nec.com.au or call 131 632
Technical data
Memory
Storage capacity for:
200 personal phone book
•
entries 80 message entries
•
10 caller lter entries
•
100 calendar entries
•
50 caller list entries
•
The capacity of the internal memory is based on shared memory, where the amount of entries on one item may affect the capacity on other items. The memory card however is based on absolute capacity for each item
Handset package content
I755 package contents
I755 handset with belt clip
•
Lithium-ion battery pack
•
Belt clip cover
•
Handset accessories
I755 handset accessories
Belt clip
•
Horizontal pouch (xed belt-clip, handset needs to be removed when used)
•
Vertical pouch (swivel belt-clip, handset can be used while in pouch)
•
Memory card
•
Battery pack
•
Desktop Charger
•
Charger rack (6 handsets) with AC Adapter
•
Bluetooth module
•
Temperature Range
Operating 0°C to +40°C
Transport –25°C to +70°C
Storage –5°C to +45°C
Relative Humidity
Operating 10 to 95%
Transport 10 to 100%
Storage 10 to 95%
Environmental conditions
Compliance
Compliance handset I755
The I755 handset carries a CE mark (European directive 93/68/EEC)
EMC EN301 489-1, EN301 489-6
EMF: EN50360
DECT: EN301 406, EN300 175 EN 300 444
Safety: EN 60950-1
Directives and regulations
Directives and regulations Europe
R&TTE directive 1999/5/EC
•
EMC directive 2004/108/EC
•
LVD directive 2006/95/EC
•
ROHS directive 2002/95/EC and WEE directive 2002/96/EC
•
Transmission
Transmission and frequency
Transmitted Radio RF power: Less than 250 mW
3)
Average Radio RF power 10mW
Frequency band EMEA: 1880 - 1900 MHz
Frequency band China: 1900 - 1920 MHz
Frequency band:
4)
• Latin America
• North America
1910 - 1930 MHz 1910 - 1930 MHz
Directives and regulations North America
FCC part 15C, 15D
•
RSS 210, RSS213
•
HAC/VC
•
3) The I755 handset supports 4 power levels: less than 250 mW, less than 100 mW, less than 50 mW and less than 25 mW. Selection of the appropriate power level is dependent on the power level indication given by the DECT system.
4) The I755 handset has a triple frequency band and can be used in the EMEA, American and Chinese DECT frequency band. The North American frequency band has a lower RF power transmission of less than 120 mW.
Compliance Bluetooth module
When equipped with an optional Bluetooth module, the I755 is in conformance with
EMC EN301 489-1, EN301 489-17
EMF: EN50371
DECT: EN300-328
Loading...