NEC Express5800/T110i System Configuration Manual

NEC Express5800/T110i
System Configuration Guide
Introduction
This document contains product and configuration information that will enable you to configure your system. The guide will
ensure fast and proper configuration of your NEC Express5800 server.
June 25, 2018 Revision 7.0
NEC Corporation
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 2
Contents
TECHNICAL SPECIFICATION ........................................................................................ 3
Specification .......................................................................................................................................... 3
EXTERNAL VIEWS ......................................................................................................... 6
Front View .............................................................................................................................................. 6
Rear Views ............................................................................................................................................. 7
Dimensions (mm) .................................................................................................................................. 8
CONFIGURATION DIAGRAM ....................................................................................... 10
Expansion Slots .................................................................................................................................. 10
SERVER CONFIGURATION ......................................................................................... 11
1 Base Models ................................................................................................................................. 11
2 Processor ..................................................................................................................................... 11
3 Memory ......................................................................................................................................... 11
4 Internal Hard Disk Drives ............................................................................................................ 13
4.1 RAID Configuration .............................................................................................................. 13
4.2 Required Components for RAID Configuration ................................................................... 17
4.3 Supported Drives ................................................................................................................. 26
5 Optical Drive ................................................................................................................................. 31
6 Flash FDD ..................................................................................................................................... 31
7 Internal RDX / LTO Drives ........................................................................................................... 32
7.1 RDX/LTO Drive Selection .................................................................................................... 32
7.2 RDX/LTO Configuration ....................................................................................................... 32
8 PCI Card ........................................................................................................................................ 33
8.1 Network Interface Controller ................................................................................................ 33
8.2 SAS Controller ..................................................................................................................... 34
8.3 Graphics Accelerator ........................................................................................................... 34
8.4 Serial Port Adapter .............................................................................................................. 34
9 Other Add-in Components .......................................................................................................... 35
9.1 Fan Kit ................................................................................................................................. 35
9.2 Trusted Platform Module Kit ................................................................................................ 35
9.3 Internal Flash Memory ......................................................................................................... 35
9.4 High Temperature Support Option ....................................................................................... 35
9.5 Input Devices ....................................................................................................................... 35
10 Add-on Components .................................................................................................................. 37
10.1 Server Management License ............................................................................................ 37
10.2 Dust Proof Kit .................................................................................................................... 37
10.3 Rack Conversion Kit .......................................................................................................... 37
10.4 Medium and Cartridge ....................................................................................................... 37
REFERENCES............................................................................................................... 38
Boot Mode Setting .............................................................................................................................. 38
Server Management ............................................................................................................................ 39
OS Support Matrix for PCI Cards and Embedded Controllers ....................................................... 40
Supported PCI cards and Installable Slots....................................................................................... 40
Copyright Notice and Liability Disclaimer ........................................................................................ 44
REVISION HISTORY ..................................................................................................... 45
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 3
Technical Specification
Specification
(1 / 2)
Model
T110i
Part Number
N8100-2707F, N8100-2534F
Processor
Type
Intel® Celeron® processor G3930
Intel® Pentium® processor G4560
Intel® Core™
i3-7300 processor
Intel® Xeon® processor E3-1220 v6
Clock speed
2.90 GHz
3.50 GHz
4 GHz
3 GHz
Number of Processors
1
Cache
2 MB
3 MB
4 MB
8 MB
Cores and Threads
2C / 2T
2C / 4T
4C / 4T
Chipset
Intel® C236 Chipset
Memory
Type
DDR4-2400 ECC Unbuffered DIMM
Standard Capacity
0 GB Maximum Capacity
64 GB (4 x 16 GB)
Internal Storage
Standard Capacity
0 GB Maximum Capacity
48 TB (4 x 12 TB)
Disk Controller
SATA : 6 Gb/s (Integrated) SATA/SAS : 6/12 Gb/s (Optional)
RAID
SATA : RAID 0/1/10 (Standard
1
)
SATA/SAS : RAID 0/1/5/6/10/50/60 (Optional)
Hot Plug
Supported with hot plug drive bay
Optical Disk Drive
Optional
5-inch Media Bays
2
Disk Drive Bays
Hot plug 2.5-inch drive configuration: 8 Hot plug 3.5-inch drive configuration: 4 Non-hot plug 3.5-inch drive configuration: 4
Expansion Slots
Total: 4 slots available 1 PCIe 3.0 x16 (x16 connector) 1 PCIe 3.0 x4 (x8 connector) 1 PCIe 3.0 x2 (x8 connector) 1 PCIe 3.0 x1 (x8 connector)
Video
Controller (VRAM)
Integrated in Server Management Controller (32MB)
Resolution / Color
1600 x 1200 / 16.7M 2
Interfaces
1 VGA (15-pin mini D-sub,1 rear) 1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear) 6 USB 3.0 (2 front, 4 rear) (plus 1 internal USB 3.0) 2 1000BASE-T LAN connector (RJ-45, 2 rear)
1 1000BASE-T LAN connector for Management (RJ-45, 1 rear)
Server Management
EXPRESSSCOPE Engine 3
System Fan
Standard
Power Supply
1 x 500 Watt 80 non-hot plug PSU 2 x 460 Watt 80 PLUS® Platinum certified Hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Power Consumption
(Max. Config, Idling)
132 VA / 131 Watt
133 VA / 132 Watt
136 VA / 135 Watt
133 VA / 132 Watt
(Max. Config, Operating)
244 VA / 242 Watt
252 VA / 250 Watt
257 VA / 255 Watt
256 VA / 254 Watt
Acoustic Noise (Sound Pressure Level) 3
Minimum Config.
28.3 dB
Maximum Config.
29.7 dB
Dimensions (W x D x H )
Standard Bezel: 175.0 x 469.3 x 367.0mm / 6.8 x 18.5 x 14.4 in Dust Proof Bezel: 175.0 x 492.0 x 367 mm / 6.8 x 19.3 x 14.4 in
Weight (Minimum / Maximum)
11 kg / 18.5 kg, 24.25 lbs. / 40.78 lbs.
Temperature, Relative Humidity (non-condensing)
Operating: 5° to 40° C / 41° to 104° F (Standard) or 5° to 48° C / 41° to 118° F (Optional), 10 to 85% Non-Operating: -10° to 55° C / 14° to 131° F, 10 to 85%
Regulatory and Safety
FCC, c-UL, CE, CB, RoHS, BSMI, CCC
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 4
Model
T110i
Operating Systems and Virtualization Software
Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter Microsoft® Windows Server® 2012 R2 Standard Microsoft® Windows Server® 2012 R2 Datacenter Microsoft® Windows Server® 2016 Standard Microsoft® Windows Server® 2016 Datacenter Red Hat Enterprise Linux 7.3 or later 4 6 VMware ESXi 6.0 Update 3
5
VMware ESXi 6.5 5
1
Embedded SATA RAID controller is supported only on limited OS.
2
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
3
Noise emission was measured in accordance with ISO 7779, at 25°C. The actual value may vary by the operating environment.
4
For Linux support, contact your sales representative or visit the NEC website at: http://www.nec.com/global/prod/express/linux/index.html
5
VMware ESXi is supported only on Xeon processor systems.
(2 / 2)
Model
T110i
Part Number
N8100-2707F, N8100-2534F
Processor
Type
Intel® Xeon® processor E3-1225 v6
Intel® Xeon® processor E3-1230 v6
Intel® Xeon® processor E3-1270 v6
Clock speed
3.30 GHz
3.50 GHz
3.80GHz
Number of Processors
1
Cache
8 MB
Cores and Threads
4C / 4T
4C / 8T
Chipset
Intel® C236 Chipset
Memory
Type
DDR4-2400 ECC Unbuffered DIMM
Standard Capacity
0 GB
Maximum Capacity
64 GB (4 x 16 GB)
Internal Storage
Standard Capacity
0 GB
Maximum Capacity
48 TB (4 x 12 TB)
Disk Controller
SATA : 6 Gb/s (Integrated) SATA/SAS : 6/12 Gb/s (Optional)
RAID
SATA : RAID 0/1/10 (Standard
1
)
SATA/SAS : RAID 0/1/5/6/10/50/60 (Optional)
Hot Plug
Supported with hot plug drive bay
Optical Disk Drive
Optional
5-inch Media Bays
2
Disk Drive Bays
Hot plug 2.5-inch drive configuration: 8 Hot plug 3.5-inch drive configuration: 4 Non-hot plug 3.5-inch drive configuration: 4
Expansion Slots
Total: 4 slots available 1 PCIe 3.0 x16 (x16 connector) 1 PCIe 3.0 x4 (x8 connector) 1 PCIe 3.0 x2 (x8 connector) 1 PCIe 3.0 x1 (x8 connector)
Video
Controller (VRAM)
Integrated in Server Management Controller (32MB)
Resolution / Color
1600 x 1200 / 16.7M 2
Interfaces
1 VGA (15-pin mini D-sub,1 rear) 1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear) 6 USB 3.0 (2 front, 4 rear) (plus 1 internal USB 3.0) 2 1000BASE-T LAN connector (RJ-45, 2 rear) 1 1000BASE-T LAN connector for Management (RJ-45, 1 rear)
Server Management
EXPRESSSCOPE Engine 3
System Fan
Standard
Power Supply
1 x 500 Watt 80 non-hot plug PSU 2 x 460 Watt 80 PLUS® Platinum certified Hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 5
Model
T110i
Power Consumption
(Max. Config, Idling)
134 VA / 133 Watt
135 VA / 134 Watt
134 VA / 133 Watt
(Max. Config, Operating)
264 VA / 262 Watt
288 VA / 286 Watt
290 VA / 288 Watt
Acoustic Noise (Sound Pressure Level) 3
Minimum Config.
28.3 dB
Maximum Config.
29.7 dB
Dimensions (W x D x H )
Standard Bezel: 175.0 x 469.3 x 367.0mm / 6.8 x 18.5 x 14.4 in Dust Proof Bezel: 175.0 x 492.0 x 367 mm / 6.8 x 19.3 x 14.4 in
Weight (Minimum / Maximum)
11 kg / 18.5 kg, 24.25 lbs. / 40.78 lbs.
Temperature, Relative Humidity (non-condensing)
Operating: 5° to 40° C / 41° to 104° F (Standard) or 5° to 48° C / 41° to 118° F (Optional), 10 to 85% Non-Operating: -10° to 55° C / 14° to 131° F, 10 to 85%
Regulatory and Safety
FCC, c-UL, CE, CB, RoHS, BSMI, CCC
Operating Systems and Virtualization Software
Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter Microsoft® Windows Server® 2012 R2 Standard Microsoft® Windows Server® 2012 R2 Datacenter Microsoft® Windows Server® 2016 Standard Microsoft® Windows Server® 2016 Datacenter Red Hat Enterprise Linux 7.3 or later 4 6 VMware ESXi 6.0 Update 3
5
VMware ESXi 6.5 5
1
Embedded SATA RAID controller is supported only on limited OS.
2
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
3
Noise emission was measured in accordance with ISO 7779, at 25°C. The actual value may vary by the operating environment.
4
For Linux support, contact your sales representative or visit the NEC website at: http://www.nec.com/global/prod/express/linux/index.html
5
VMware ESXi is supported only on Xeon processor systems.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 6
External Views
Front View
With Front bezel
Hot Plug 2.5-inch Drive Configuration
Hot Plug 3.5-inch Drive Configuration
Non-hot Plug 3.5-inch Drive Configuration
Legend
A.
Power Button
J.
USB 3.0 Connectors
B.
Dump (NMI) Button
K.
Drive Bay Cover
C.
BMC Reset Button
L.
Cover Key
D.
Power LED
M.
Stabilizer
E.
Power Capping LED
N.
5.25-inch Media Bay 1
F.
System Status LED 1
O.
5.25-inch Media Bay 2
G.
System Status LED 2
P.
Optical Disk Drive
H.
Global LED 1
Q.
2.5-inch Drive Bay
I.
Global LED 2
R.
3.5-inch Drive Bay
A
G
E
C
K
J
L
I
B
D
F
H
M
P
O
N
Q
R
P
O
N
R
P
O
N
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 7
Rear Views
Hot Plug Power Supply Configuration
Non-hot Plug Power Supply Configuration
Legend
A.
Serial Port Connector
E.
Data LAN Connectors
B.
VGA Connector
F.
PCI Slots
C.
USB Connectors
G.
AC Inlet
D.
Management LAN Connector
H.
Power Supply Unit
D
C
B
A
G
E
F
H
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 8
Dimensions (mm)
Standard Bezel Non-redundant Power Configuration
Redundant Power Configuration
469.3
175.0
249.0498.4
367.0
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 9
Dust Proof Bezel Non-redundant Power Configuration
Redundant Power Configuration
518.2
492.0
367.0
175.0
249.0
492.0
175.
249.
506.
492.
367.0
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 10
Configuration Diagram
Legend: Standard components Mandatory components
Expansion Slots
Legend
#1
PCIe 3.0 x2, x8 connector, Full Height, up to 173mm length
#2
PCIe 3.0 x1, x8 connector, Full Height, up to 173mm length
#3
PCIe 3.0 x16, x16 connector, Full Height, up to 312mm length
#4
PCIe 3.0 x4, x8 connector, Full Height, up to 173mm length
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 11
Server Configuration
1 Base Models
Product Name / Description
Part Number
NEC Express5800/T110i
no CPU, no RAM, no Drive Cage, no HDD, no Optiocal Drive, no Keyboard, no Mouse Including: 1x 500 Watt non-hot plug power supply
N8100-2707F
NEC Express5800/T110i
no CPU, no RAM, no Drive Cage, no HDD, no Optiocal Drive, no Keyboard, no Mouse Including: 2x 460 Watt hot plug power supply
N8100-2534F
NOTE:
The base model must be ordered with a processor kit, memory, a drive cage, and an optical drive. Keyboard and mouse are not included in the base models. Please order separately if necessary.
2 Processor
Available sockets: 1
Category
Product Name / Description
Part Number
Processors
Required
Celeron G3930 Processor Kit
Intel® Celeron ® Processor G3930 (2.9 GHz, 2C/2T, 2 MB)
N8101-1085F
Pentium G4560 Processor Kit
Intel® Pentium ® Processor G4560 (3.5 GHz, 2C/4T, 3 MB)
N8101-1086F
Core i3-7300 Processor Kit
Intel® Core i3-7300 Processor (4 GHz, 2C/4T, 4 MB)
N8101-1087F
Xeon E3-1220 v6 Processor Kit
Intel® Xeon ® Processor E3-1220 v6 (3.0 GHz, 4C/4T, 8 MB)
N8101-1091F
Xeon E3-1225 v6 Processor Kit
Intel® Xeon ® Processor E3-1225 v6 (3.3 GHz, 4C/4T, 8 MB)
N8101-1090F
Xeon E3-1230 v6 Processor Kit
Intel® Xeon ® Processor E3-1230 v6 (3.5 GHz, 4C/8T, 8 MB)
N8101-1089F
Xeon E3-1270 v6 Processor Kit
Intel® Xeon ® Processor E3-1270 v6 (3.8 GHz, 4C/8T, 8 MB)
N8101-1088F
NOTE:
One processor kit from above must be installed. VMware ESXi is not supported on Celeron processor systems, Pentium processor or Core i3 processor systems.
3 Memory
Available slots: 4
Product Name / Description
Part Number
8GB DDR4-2400 UNB Memory Kit
8GB Unbuffered ECC DIMM, DDR4-2400
N8102-701F
16GB DDR4-2400 UNB Memory Kit
16GB Unbuffered ECC DIMM, DDR4-2400
N8102-702F
NOTE:
Minimum one memory kit must be installed. It is recommended to install memory kits in pairs of two identical DIMMs for dual-channel symmetric memory configurations to
increase memory transfer speed.
At least 5 GB of memory is required for VMware ESXi™ 6.0, and VMware ESXi™ 6.5.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 12
Maximum Available Memory
See the table below for the maximum memory size that you can actually use on your system.
Maximum Memory Size Supported by Operating Systems
Maximum Available Memory
Microsoft Windows Server 2012 Standard Microsoft Windows Server 2012 Datacenter Microsoft Windows Server 2012 R2 Standard Microsoft Windows Server 2012 R2 Datacenter
4 TB 1
64 GB
Microsoft Windows Server 2016 Standard Microsoft Windows Server 2016 Datacenter
24TB 1
64GB Red Hat Enterprise Linux 7
6 TB
64 GB
VMware ESXi 6.0
6 TB 2
64 GB
VMware ESXi 6.5
12TB 3
64 GB
1
The maximum available memory size of Hyper-V systems are below:
Windows Server 2012 and Windows Server 2012 R2 : 4 TB Windows Server 2016 : 24 TB
2
Up to 4 TB of main memory is available to each virtual machine.
3
Up to 6 TB of main memory is available to each virtual machine.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 13
4 Internal Hard Disk Drives
4.1 RAID Configuration
Refer to the section in accordance with your disk form factor and RAID configuration
4.1.1 2.5-inch Drive
Operating System
Supported RAID configuration
Supported
HDD/SSD RAID and Cache
Section
VMware ESXi 6.0
Non-RAID (Embedded SATA)
4.2.1
4.3.1
RAID 0/1/10 No Cache
4.2.4
4.3.3
RAID 0/1/10 1GB Cache
4.2.5
RAID 5/6/50/60 1GB Cache
4.2.7
RAID 5/6/50/60 2GB Cache
4.2.8
Windows Server 2012 Windows Server 2012 R2 Windows Server 2016
Non-RAID (Embedded SATA)
4.2.1
4.3.1
RAID 0/1 (Embedded SATA RAID)
4.2.2
4.3.2
RAID 0/1/10 No Cache
4.2.4
4.3.4
RAID 0/1/10 1GB Cache
4.2.5
RAID 0/1/10 2GB Cache
4.2.6
RAID 5/6/50/60 1GB Cache
4.2.7
RAID 5/6/50/60 2GB Cache
4.2.9
RAID 5/6/50/60 4GB Cache
4.2.10
Red Hat Enterprise Linux 7
Non-RAID (Embedded SATA)
4.2.1
4.3.1
RAID 0/1/10 No Cache
4.2.4
4.3.4
RAID 0/1/10 1GB Cache
4.2.5
RAID 0/1/10 2GB Cache
4.2.6
RAID 5/6/50/60 1GB Cache
4.2.7
RAID 5/6/50/60 2GB Cache
4.2.9
RAID 5/6/50/60 4GB Cache
4.2.10
VMware ESXi 6.5
Non-RAID (Embedded SATA)
4.2.1
4.3.1
RAID 0/1/10 No Cache
4.2.3
4.3.4
RAID 0/1/10 1GB Cache
4.2.5
RAID 5/6/50/60 1GB Cache
4.2.7
RAID 5/6/50/60 2GB Cache
4.2.8
NOTE:
Up to four drives can be installed when you choose the Embedded SATA Non-RAID controller. All drives within a RAID array should be of the same capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs (512n), SAS 10K HDDs (512e), SAS 15K HDDs, SATA HDDs, SAS
SSDs, SATA SSDs (ME), and SATA SSDs (VE) can be mixed in a system.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.
Slot 1
Slot 3
Slot 2
Slot 4
Slot 5
Slot 7
Slot 6
Slot 0
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 14
4.1.2 Hot plug 3.5-inch Drive
Operating System
Supported RAID configuration
Supported
HDD/SSD RAID and Cache
Section
VMware ESXi 6.0
Non-RAID (Embedded SATA)
4.2.11
4.3.5
RAID 0/1/10 No Cache
4.2.13
RAID 0/1/10 1GB Cache
4.2.15
RAID 5/6/50/60 1GB Cache
4.2.17
RAID 5/6/50/60 2GB Cache
4.2.18
Windows Server 2012 Windows Server 2012 R2 Windows Server 2016
Non-RAID (Embedded SATA)
4.2.11
4.3.5
RAID 0/1 (Embedded SATA RAID)
4.2.12
4.3.6
RAID 0/1/10 No Cache
4.2.14
RAID 0/1/10 1GB Cache
4.2.15
RAID 0/1/10 2GB Cache
4.2.16
RAID 5/6/50/60 1GB Cache
4.2.17
RAID 5/6/50/60 2GB Cache
4.2.19
RAID 5/6/50/60 4GB Cache
4.2.20
VMware ESXi 6.5
Non-RAID (Embedded SATA)
4.2.11
4.3.5
RAID 0/1/10 No Cache
4.2.14
4.3.6
RAID 0/1/10 1GB Cache
4.2.15
RAID 5/6/50/60 1GB Cache
4.2.16
RAID 5/6/50/60 2GB Cache
4.2.17
RAID 5/6/50/60 2GB Cache
4.2.19
RAID 5/6/50/60 4GB Cache
4.2.20
Red Hat Enterprise Linux 7
Non-RAID (Embedded SATA)
4.2.11
4.3.5
RAID 0/1/10 No Cache
4.2.13
4.3.6
RAID 0/1/10 1GB Cache
4.2.15
RAID 5/6/50/60 1GB Cache
4.2.17
RAID 5/6/50/60 2GB Cache
4.2.18
NOTE:
All hard drives within a RAID array should be of the same capacity and rotation speed.
Slot 0
Slot 1
Slot 2
Slot 3
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 15
4.1.3 Non-hot plug 3.5-inch Drive
Operating System
Supported RAID configuration
Supported
HDD/SSD RAID and Cache
Section
VMware ESXi 6.0
Non-RAID (Embedded SATA)
4.2.21
4.3.7
RAID 0/1/10 No Cache
4.2.23
RAID 0/1/10 1GB Cache
4.2.25
RAID 5/6/50/60 1GB Cache
4.2.27
RAID 5/6/50/60 2GB Cache
4.2.28
Windows Server 2012 Windows Server 2012 R2 Windows Server 2016
Non-RAID (Embedded SATA)
4.2.21
4.3.7
RAID 0/1 (Embedded SATA RAID)
4.2.22
4.3.8
RAID 0/1/10 No Cache
4.2.24
RAID 0/1/10 2GB Cache
4.2.26
RAID 5/6/50/60 2GB Cache
4.2.29
RAID 5/6/50/60 4GB Cache
4.2.30
VMware ESXi 6.5
Non-RAID (Embedded SATA)
4.2.21
4.3.7
RAID 0/1/10 No Cache
4.2.24
4.3.8
RAID 0/1/10 2GB Cache
4.2.26
RAID 5/6/50/60 2GB Cache
4.2.29
RAID 5/6/50/60 4GB Cache
4.2.30
Red Hat Enterprise Linux 7
Non-RAID (Embedded SATA)
4.2.21
4.3.7
RAID 0/1/10 No Cache
4.2.23
4.3.8
RAID 0/1/10 1GB Cache
4.2.25
RAID 5/6/50/60 1GB Cache
4.2.27
RAID 5/6/50/60 2GB Cache
4.2.28
NOTE:
All hard drives within a RAID array should be of the same capacity and rotation speed.
4.1.4 M.2 SATA SSD
The M.2 SATA SSD can be used for boot drive only. See the table below for the system configuration of M.2 SATA SSD and support for the mixed installation of M.2 SATA SSDs and internal hard drives.
Operating System
M.2 SATA SSD configuration
Support for the mixed
installation of M.2 SATA
SSD and internal hard
drives.
RAID and Cache
Section
VMware ESXi 6.5
RAID 0/1/10 No Cache
4.2.33
Not supported
RAID 0/1/10 1GB Cache
4.2.34
RAID 0/1/10 2GB Cache
4.2.35
Windows Server 2012 Windows Server 2012 R2 Windows Server 2016
RAID 0/1 (Embedded SATA RAID)
4.2.31
Supported: Optional RAID controller is required to install internal hard drives.
RAID 0/1/10 No Cache
4.2.33
Not supported RAID 0/1/10 1GB Cache
4.2.34
Slot 0
Slot 1
Slot 2
Slot 3
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 16
RAID 0/1/10 2GB Cache
4.2.35
VMware ESXi 6.0 Red Hat Enterprise Linux 7
RAID 0/1/10 No Cache
4.2.33
Not supported RAID 0/1/10 1GB Cache
4.2.34
NOTE:
A drive cage kit is required when no internal hard drive is installed.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 17
4.2 Required Components for RAID Configuration
4.2.1 Embedded SATA Non-RAID Controller for 2.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4 x 6Gb/s SATA
(Standard)
Cable
Internal SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD
(Attached in Cage)
Drive Cage
Required
2.5-inch Hot Plug Drive Cage Kit
8 x 2.5-inch hot plug hard drive bays
N8154-80F
NOTE
Hot plug insertion/removal is not supported with the embedded SATA Non-RAID controller.
4.2.2 Embedded SATA RAID Controller for 2.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4 x 6Gb/s SATA, RAID0/1/10 capable
(Standard)
Cable
Internal SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD
(Attached in Cage)
Drive Cage
Required
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
N8154-80F
NOTE
All hard drives within a RAID array should be of the same capacity.
4.2.3 RAID 0/1 Controller without Cache for 2.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (RAID 0/1)
Broadcom MegaRAID SAS 9341-8i RAID0/1/10, no memory cache, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s
N8103-188
Cable
Internal SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD
(Attached in Cage)
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, for 5th - 8th hard drives
K410-340(00)
Drive Cage
Required
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
N8154-80F
NOTE:
All drives within a RAID array should be of the same type, capacity and rotation speed..
4.2.4 RAID 0/1 Controller without Cache for 2.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (RAID 0/1)
Avago(LSI) MegaRAID SAS 944N-8i RAID0/1/10, no memory cache, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s
N8103-205
Cable
Internal SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD
(Attached in Cage)
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, for 5th - 8th hard drives
K410-340(00)
Drive Cage
Required
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
N8154-80F
NOTE:
All drives within a RAID array should be of the same type, capacity and rotation speed.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 18
4.2.5 RAID 0/1 Controller with 1 GB Cache for 2.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1)
Broadcom MegaRAID SAS 9362-8i RAID0/1/10, 1GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s
N8103-176
Flash Backup
Recommended
Flash Backup Unit
for Broadcom MegaRAID SAS 9362-8i 500mm Cable for Flash Backup Unit included
N8103-180
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD
(Attached in Cage)
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, for 5th - 8th hard drives
K410-340(00)
Drive Cage
Required
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
N8154-80F
NOTE:
All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs, SATA SSDs (ME), and SATA
SSDs (VE) can be mixed in a system.
4.2.6 RAID 0/1 Controller with 2 GB Cache for 2.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (2GB, RAID 0/1, WT/WB)
Avago(LSI) MegaRAID SAS 946N-8i
RAID 0/1/10, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-206
RAID Controller (2GB, RAID 0/1, WT)
Avago(LSI) MegaRAID SAS 945N-8i RAID 0/1/10, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-210
Flash Backup
Recommended
Flash Buckup Unit
for Avago(LSI) MegaRAID SAS 946N-8i 550mm Cable for Flash Backup Unit included
NOTE:
It can not be connected to N8103-210 RAID Controller
N8103-209
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD
(Attached in Cage)
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, for 5th - 8th hard drives
K410-340(00)
Drive Cage
Required
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
N8154-80F
NOTE:
All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SATA SSD and SAS SSDs can be
mixed.
4.2.7 RAID 5/6 Controller with 1 GB Cache for 2.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
Broadcom MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 1GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s
N8103-177
Flash Backup
Recommended
Flash Backup Unit
for Broadcom MegaRAID SAS 9362-8i 500mm Cable for Flash Backup Unit included
N8103-180
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD
(Attached in Cage)
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, for 5th - 8th hard drives
K410-340(00)
Drive Cage
Required
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
N8154-80F
NOTE:
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 19
All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs, SATA SSDs (ME), and SATA
SSDs (VE) can be mixed in a system.
4.2.8 RAID 5/6 Controller with 2 GB Cache for 2.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (2GB, RAID 0/1/5/6)
Broadcom MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 2 GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s
N8103-178
Flash Backup
Recommended
Flash Backup Unit
for Broadcom MegaRAID SAS 9362-8i 500mm Cable for Flash Backup Unit included
N8103-180
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD
(Attached in Cage)
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, for 5th - 8th hard drives
K410-340(00)
Drive Cage
Required
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
N8154-80F
NOTE:
All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs, SATA SSDs (ME), and SATA
SSDs (VE) can be mixed in a system.
4.2.9 RAID 5/6 Controller with 2 GB Cache for 2.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (2GB, RAID 0/1/5/6, WT/WB)
Avago(LSI) MegaRAID SAS 946N-8i RAID0/1/5/6/10/50/60, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-207
RAID Controller (2GB, RAID 0/1/5/6, WT)
Avago(LSI) MegaRAID SAS 945N-8i RAID0/1/5/6/10/50/60, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-211
Flash Backup
Recommended
Flash Backup Unit
for Avago(LSI) MegaRAID SAS 946N-8i 550mm Cable for Flash Backup Unit included
NOTE:
It can not be connected to N8103-211 RAID Controller
N8103-209
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD
(Attached in Cage)
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, for 5th - 8th hard drives
K410-340(00)
Drive Cage
Required
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
N8154-80F
NOTE:
All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SATA SSD and SAS SSDs can be
mixed.
4.2.10 RAID 5/6 Controller with 2 GB Cache for 2.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (2GB, RAID 0/1/5/6)
Avago(LSI) MegaRAID SAS 946N-8i RAID0/1/5/6/10/50/60, 4GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s
N8103-208
Flash Backup
Recommended
Flash Backup Unit
for Avago(LSI) MegaRAID SAS 946N-8i 550mm Cable for Flash Backup Unit included
N8103-209
Cable
Internal SAS/SATA Cable
(Attached in Cage)
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 20
1 x Mini SAS HD to 1 x Mini SAS HD
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, for 5th - 8th hard drives
K410-340(00)
Drive Cage
Required
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
N8154-80F
NOTE:
All drives within a RAID array should be of the same type, capacity and rotation speed.
4.2.11 Embedded SATA Non-RAID Controller for 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4 x 6Gb/s SATA
(Standard)
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD
(Attached in Cage)
Drive Cage
Required
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
N8154-79F
NOTE
Hot plug insertion/removal is not supported with the embedded SATA Non-RAID controller.
4.2.12 Embedded SATA RAID Controller for 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4 x 6Gb/s SATA, RAID0/1/10 capable
(Standard)
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD
(Attached in Cage)
Drive Cage
Required
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
N8154-79F
NOTE:
All hard drives within a RAID array should be of the same capacity. Embedded SATA RAID Controller does not support RAID 10 configured with 2TB or more HDDs.
4.2.13 RAID 0/1 Controller without Cache for 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (RAID 0/1)
Broadcom MegaRAID SAS 9341-8i RAID0/1/10, no memory cache, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s
N8103-188
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD
(Attached in Cage)
Drive Cage
Required
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
N8154-79F
NOTE:
All hard drives within a RAID array should be of the same capacity.
4.2.14 RAID 0/1 Controller without Cache for 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (RAID 0/1)
Avago(LSI) MegaRAID SAS 944N-8i RAID0/1/10, no memory cache, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s
N8103-205
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD
(Attached in Cage)
Drive Cage
Required
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
N8154-79F
NOTE:
All hard drives within a RAID array should be of the same capacity.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 21
4.2.15 RAID 0/1 Controller with 1 GB Cache for 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1)
Broadcom MegaRAID SAS 9362-8i RAID0/1/10, 1GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s
N8103-176
Flash Backup
Recommended
Flash Backup Unit
for Broadcom MegaRAID SAS 9362-8i 500mm Cable for Flash Backup Unit included
N8103-180
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD
(Attached in Cage)
Drive Cage
Required
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
N8154-79F
NOTE:
All hard drives within a RAID array should be of the same capacity.
4.2.16 RAID 0/1 Controller with 2 GB Cache for 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (2GB, RAID 0/1)
Avago(LSI) MegaRAID SAS 946N-8i RAID0/1/10, 2GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s
N8103-206
RAID Controller (2GB, RAID 0/1, WT)
Avago(LSI) MegaRAID SAS 945N-8i RAID 0/1/10, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-210
Flash Backup
Recommended
Flash Buckup Unit
for Avago(LSI) MegaRAID SAS 946N-8i 550mm Cable for Flash Backup Unit included
NOTE:
It can not be connected to N8103-210 RAID Controller
N8103-209
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD
(Attached in Cage)
Drive Cage
Required
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
N8154-79F
NOTE:
All hard drives within a RAID array should be of the same capacity.
4.2.17 RAID 5/6 Controller with 1 GB Cache for 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
Broadcom MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 1GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s
N8103-177
Flash Backup
Recommended
Flash Backup Unit
for Broadcom MegaRAID SAS 9362-8i 500mm Cable for Flash Backup Unit included
N8103-180
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD
(Attached in Cage)
Drive Cage
Required
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
N8154-79F
NOTE
All hard drives within a RAID array should be of the same capacity.
4.2.18 RAID 5/6 Controller with 2 GB Cache for 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (2GB, RAID 0/1/5/6)
Broadcom MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 2 GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s
N8103-178
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 22
Flash Backup
Recommended
Flash Backup Unit
for Broadcom MegaRAID SAS 9362-8i 500mm Cable for Flash Backup Unit included
N8103-180
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD
(Attached in Cage)
Drive Cage
Required
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
N8154-79F
NOTE
All hard drives within a RAID array should be of the same capacity.
4.2.19 RAID 5/6 Controller with 2 GB Cache for 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (2GB, RAID 0/1/5/6, WT/WB)
Avago(LSI) MegaRAID SAS 946N-8i RAID0/1/5/6/10/50/60, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-207
RAID Controller (2GB, RAID 0/1/5/6, WT)
Avago(LSI) MegaRAID SAS 945N-8i RAID0/1/5/6/10/50/60, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-211
Flash Backup
Recommended
Flash Backup Unit
for Avago(LSI) MegaRAID SAS 946N-8i 550mm Cable for Flash Backup Unit included
NOTE:
It can not be connected to N8103-211 RAID Controller
N8103-209
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD
(Attached in Cage)
Drive Cage
Required
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
N8154-79F
NOTE:
All hard drives within a RAID array should be of the same capacity.
4.2.20 RAID 5/6 Controller with 4 GB Cache for 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (4GB, RAID 0/1/5/6)
Avago(LSI) MegaRAID SAS 946N-8i RAID0/1/5/6/10/50/60, 4GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s
N8103-208
Flash Backup
Recommended
Flash Backup Unit
for Avago(LSI) MegaRAID SAS 946N-8i 550mm Cable for Flash Backup Unit included
N8103-209
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD
(Attached in Cage)
Drive Cage
Required
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
N8154-79F
NOTE:
All hard drives within a RAID array should be of the same capacity.
4.2.21 Embedded SATA Non-RAID Controller for Non-hot plug 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4 x 6Gb/s SATA
(Standard)
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA
(Attached in Cage)
Drive Cage
Required
3.5-inch Drive Cage
4 x 3.5-inch non-hot plug drive bays
N8154-81F
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 23
4.2.22 Embedded SATA RAID Controller for Non-hot plug 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4 x 6Gb/s SATA, RAID0/1/10 capable
(Standard)
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA
(Attached in Cage)
Drive Cage
Required
3.5-inch Drive Cage
4 x 3.5-inch non-hot plug drive bays
N8154-81F
NOTE:
All hard drives within a RAID array should be of the same capacity. Embedded SATA RAID Controller does not support RAID 10 configured with 2TB or more HDDs.
4.2.23 RAID 0/1 Controller without Cache for Non-hot plug 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (RAID 0/1)
Broadcom MegaRAID SAS 9341-8i RAID0/1/10, no memory cache, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s
N8103-188
Cable
Required
RAID LED Cable
K410-293(00)
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA
(Attached in Cage)
Drive Cage
Required
3.5-inch Drive Cage
4 x 3.5-inch non-hot plug drive bays
N8154-81F
NOTE:
All hard drives within a RAID array should be of the same capacity.
4.2.24 RAID 0/1 Controller without Cache for Non-hot plug 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (RAID 0/1)
Avago(LSI) MegaRAID SAS 944N-8i
RAID0/1/10, no memory cache, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s
N8103-205
Cable
Required
RAID LED Cable
K410-444(00)
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA
(Attached in Cage)
Drive Cage
Required
3.5-inch Drive Cage
4 x 3.5-inch non-hot plug drive bays
N8154-81F
NOTE:
All hard drives within a RAID array should be of the same capacity.
4.2.25 RAID 0/1 Controller with 1 GB Cache for Non-hot plug 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1)
Broadcom MegaRAID SAS 9362-8i RAID0/1/10, 1GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s
N8103-176
Flash Backup
Recommended
Flash Backup Unit
for Broadcom MegaRAID SAS 9362-8i 500mm Cable for Flash Backup Unit included
N8103-180
Cable
Required
RAID LED Cable
K410-293(00)
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA
(Attached in Cage)
Drive Cage
Required
3.5-inch Drive Cage
4 x 3.5-inch non-hot plug drive bays
N8154-81F
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 24
NOTE:
All hard drives within a RAID array should be of the same capacity.
4.2.26 RAID 5/6 Controller with 2 GB Cache for Non-hot plug 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (2GB, RAID 0/1, WT/WB)
Avago(LSI) MegaRAID SAS 946N-8i
RAID 0/1/10, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-206
RAID Controller (2GB, RAID 0/1, WT)
Avago(LSI) MegaRAID SAS 945N-8i
RAID 0/1/10, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-210
Flash Backup
Recommended
Flash Backup Unit
for Avago(LSI) MegaRAID SAS 946N-8i 550mm Cable for Flash Backup Unit included
NOTE:
It can not be connected to N8103-210 RAID Controller
N8103-209
Cable
Required
RAID LED Cable
K410-444(00)
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA
(Attached in Cage)
Drive Cage
Required
3.5-inch Drive Cage
4 x 3.5-inch non-hot plug drive bays
N8154-81F
NOTE:
All hard drives within a RAID array should be of the same capacity.
4.2.27 RAID 5/6 Controller with 1 GB Cache for Non-hot plug 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1)
Broadcom MegaRAID SAS 9362-8i RAID0/1/10, 1GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s
N8103-177
Flash Backup
Recommended
Flash Backup Unit
for Broadcom MegaRAID SAS 9362-8i 500mm Cable for Flash Backup Unit included
N8103-180
Cable
Required
RAID LED Cable
K410-293(00)
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA
(Attached in Cage)
Drive Cage
Required
3.5-inch Drive Cage
4 x 3.5-inch non-hot plug drive bays
N8154-81F
NOTE:
All hard drives within a RAID array should be of the same capacity.
4.2.28 RAID 5/6 Controller with 2 GB Cache for Non-hot plug 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (2GB, RAID 0/1/5/6)
Broadcom MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 2 GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s
N8103-178
Flash Backup
Recommended
Flash Buckup Unit
for Broadcom MegaRAID SAS 9362-8i 500mm Cable for Flash Backup Unit included
N8103-180
Cable
Required
RAID LED Cable
K410-293(00)
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA
(Attached in Cage)
Drive Cage
Required
3.5-inch Drive Cage
4 x 3.5-inch non-hot plug drive bays
N8154-81F
NOTE:
All hard drives within a RAID array should be of the same capacity.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 25
4.2.29 RAID 5/6 Controller with 2 GB Cache for Non-hot plug 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (2GB, RAID 0/1/5/6, WT/WB)
Avago(LSI) MegaRAID SAS 946N-8i
RAID0/1/5/6/10/50/60, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-207
RAID Controller (2GB, RAID 0/1/5/6, WT)
Avago(LSI) MegaRAID SAS 945N-8i RAID0/1/5/6/10/50/60, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-211
Flash Backup
Recommended
Flash Backup Unit
for Avago(LSI) MegaRAID SAS 946N-8i 550mm Cable for Flash Backup Unit included
NOTE:
It can not be connected to N8103-210 RAID Controller
N8103-209
Cable
Required
RAID LED Cable
K410-444(00)
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA
(Attached in Cage)
Drive Cage
Required
3.5-inch Drive Cage
4 x 3.5-inch non-hot plug drive bays
N8154-81F
NOTE:
All hard drives within a RAID array should be of the same capacity.
4.2.30 RAID 5/6 Controller with 4 GB Cache for Non-hot plug 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (4GB, RAID 0/1/5/6)
Avago(LSI) MegaRAID SAS 946N-8i
RAID0/1/5/6/10/50/60, 4GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s
N8103-208
Flash Backup
Recommended
Flash Buckup Unit
for Avago(LSI) MegaRAID SAS 946N-8i 550mm Cable for Flash Backup Unit included
N8103-209
Cable
Required
RAID LED Cable
K410-444(00)
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA
(Attached in Cage)
Drive Cage
Required
3.5-inch Drive Cage
4 x 3.5-inch non-hot plug drive bays
N8154-81F
4.2.31 Embedded SATA RAID Controller for M.2 SATA SSD
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4x 6Gb/s SATA, RAID 0/1/10 capable
(Standard)
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 2 x Single SATA, 1 set
K410-365(00)
Installation Kit
Dual M.2 SATA Mount Kit
M.2 PCIe SSD adapter, 2 x M.2 socket
N8118-307
Drive
2 slots available
120GB M.2 SATA SSD
1 x 120GB M.2 SATA SSD, 6Gb/s, 512n sector
N8150-736
4.2.32 RAID 0/1 Controller with 0 MB Cache for M.2 SATA SSD
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (RAID 0/1)
Broadcom MegaRAID SAS 9341-8i RAID 0/1/10, Non-cache, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-188
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 26
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 2 x Single SATA, 1 set
K410-365(00)
Installation Kit
Dual M.2 SATA Mount Kit
M.2 PCIe SSD adapter, 2 x M.2 socket
N8118-307
Drive
2 slots available
120GB M.2 SATA SSD
1 x 120GB M.2 SATA SSD, 6Gb/s, 512n sector
N8150-736
4.2.33 RAID 0/1 Controller with 0 MB Cache for M.2 SATA SSD
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (RAID 0/1)
Avago(LSI) MegaRAID SAS 944N-8i
RAID0/1/10, no memory cache, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s
N8103-205
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 2 x Single SATA, 1 set
K410-365(00)
Installation Kit
Dual M.2 SATA Mount Kit
M.2 PCIe SSD adapter, 2 x M.2 socket
N8118-307
Drive
2 slots available
120GB M.2 SATA SSD
1 x 120GB M.2 SATA SSD, 6Gb/s, 512n sector
N8150-736
4.2.34 RAID 0/1 Controller with 1 GB Cache for M.2 SATA SSD
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1)
Broadcom MegaRAID SAS 9362-8i RAID 0/1/10, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-176
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 2 x Single SATA, 1 set
K410-365(00)
Installation Kit
Dual M.2 SATA Mount Kit
M.2 PCIe SSD adapter, 2 x M.2 socket
N8118-307
Drive
2 slots available
120GB M.2 SATA SSD
1 x 120GB M.2 SATA SSD, 6Gb/s, 512n sector
N8150-736
4.2.35 RAID 0/1 Controller with 2 GB Cache for M.2 SATA SSD
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (2GB, RAID 0/1, WT/WB)
Avago(LSI) MegaRAID SAS 946N-8i
RAID 0/1/10, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-206
RAID Controller (2GB, RAID 0/1, WT)
Avago(LSI) MegaRAID SAS 945N-8i
RAID 0/1/10, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-210
Flash Backup
Recommended
Flash Backup Unit
for Avago(LSI) MegaRAID SAS 946N-8i 550mm Cable for Flash Backup Unit included
NOTE:
It can not be connected to N8103-210 RAID Controller
N8103-209
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 2 x Single SATA, 1 set
K410-365(00)
Installation Kit
Dual M.2 SATA Mount Kit
M.2 PCIe SSD adapter, 2 x M.2 socket
N8118-307
Drive
2 slots available
120GB M.2 SATA SSD
1 x 120GB M.2 SATA SSD, 6Gb/s, 512n sector
N8150-736
4.3 Supported Drives
4.3.1 2.5-inch Drives (1)
Category
Product Name / Description
Part Number
Drive
SATA
500GB 7.2K Hot Plug 2.5-inch SATA HDD
N8150-488
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 27
4 slots available
HDD (512n)
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-489
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-527
4.3.2 2.5-inch Drives (2)
Category
Product Name / Description
Part Number
Drive
4 slots available
SATA HDD (512n)
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-488
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-489
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-527
SATA SSD (ME)
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
N8150-779
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
N8150-780
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
N8150-781
SATA SSD (VE)
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, 2.5-inch, 6b/s, 512n sector, VE
N8150-782
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, 2.5-inch, 6b/s, 512n sector, VE
N8150-783
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, 2.5-inch, 6b/s, 512n sector, VE
N8150-784
1.6TB Hot Plug 2.5-inch SATA SSD
1 x 1.6 TB SATA SSD, 2.5-inch, 6b/s, 512n sector, VE
N8150-785
NOTE:
Embedded SATA RAID Controller does not support RAID 10 configured with 2TB or more HDDs.
4.3.3 2.5-inch Drives (3)
Category
Product Name / Description
Part Number
Drive
8 slots available
SAS HDD (512n)
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-479
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-480
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-481
900GB 10K Hot Plug 2.5-inch SAS HDD
1 x 900 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-482
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1 x 1.2TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-483
300GB 15K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
N8150-485
450GB 15K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
N8150-486
600GB 15K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
N8150-518
SATA HDD (512n)
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-488
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-489
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-527
SAS SSD (eMLC)
200GB Hot Plug 2.5-inch SAS SSD
1 x 200 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
N8150-721
400GB Hot Plug 2.5-inch SAS SSD
1 x 400 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
N8150-722
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
N8150-779
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 28
SATA SSD (ME)
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
N8150-780
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
N8150-781
SATA SSD (VE)
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, 2.5-inch, 6b/s, 512n sector, VE
N8150-782
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, 2.5-inch, 6b/s, 512n sector, VE
N8150-783
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, 2.5-inch, 6b/s, 512n sector, VE
N8150-784
1.6TB Hot Plug 2.5-inch SATA SSD
1 x 1.6 TB SATA SSD, 2.5-inch, 6b/s, 512n sector, VE
N8150-785
NOTE:
All hard drives within a RAID array should be of the same capacity. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs, SATA SSDs (ME), and SATA
SSDs (VE) can be mixed in a system.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.
4.3.4 2.5-inch Drives (4)
Category
Product Name / Description
Part Number
Drive
8 slots available
SAS HDD (512n)
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-479
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-480
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-481
900GB 10K Hot Plug 2.5-inch SAS HDD
1 x 900 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-482
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1 x 1.2TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-483
300GB 15K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
N8150-485
450GB 15K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
N8150-486
600GB 15K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
N8150-518
SAS HDD (512e)
1.8TB 10K Hot Plug 2.5-inch SAS HDD
1x 1.8TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512e sector
N8150-541
2.4TB 10K Hot Plug 2.5-inch SAS HDD
1x 2.4TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512e sector
NOTE:
- It can not be connected to the N8103-176/-177/-178/-188 RAID controller.
N8150-599
900GB 15K Hot Plug 2.5-inch SAS HDD
1x 900GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512e sector
N8150-586
SATA HDD (512n)
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-488
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-489
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-527
SAS SSD (eMLC)
200GB Hot Plug 2.5-inch SAS SSD
1 x 200 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
N8150-721
400GB Hot Plug 2.5-inch SAS SSD
1 x 400 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
N8150-722
SATA SSD (ME)
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
N8150-779
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
N8150-780
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
N8150-781
200GB Hot Plug 2.5-inch SATA SSD
N8150-782
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 29
SATA SSD (VE)
1 x 200 GB SATA SSD, 2.5-inch, 6b/s, 512n sector, VE
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, 2.5-inch, 6b/s, 512n sector, VE
N8150-783
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, 2.5-inch, 6b/s, 512n sector, VE
N8150-784
1.6TB Hot Plug 2.5-inch SATA SSD
1 x 1.6 TB SATA SSD, 2.5-inch, 6b/s, 512n sector, VE
N8150-785
NOTE:
All hard drives within a RAID array should be of the same capacity. Up to two kinds of drives selected from SAS 10K HDDs (512n), SAS 10K HDDs (512e), SAS 15K HDDs, SATA HDDs, SAS
SSDs, SATA SSDs (ME), and SATA SSDs (VE) can be mixed in a system.
For 512e sector HDD, the supported operating systems of virtual machines on Hyper-V are:
- Windows Server 2008 R2 SP1 or later
- Windows 7 SP1 or later
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.
4.3.5 Hot Plug 3.5-inch Drives (1)
Category
Product Name / Description
Part Number
Drive
4slots available
SATA HDD (512n)
500GB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-524
1TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-504
2TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-505
3TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-506
4TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-507
NOTE:
Hot plug insertion/removal is not supported with the embedded SATA Non-RAID controller.
4.3.6 Hot Plug 3.5-inch Drives (2)
Category
Product Name / Description
Part Number
Drive
4 slots available
SATA HDD (512n)
500GB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-524
1TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-504
2TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-505
3TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-506
4TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-507
SATA HDD (512e)
6TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 6 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512e sector
N8150-540
8TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 8 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512e Sector
N8150-528
10TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 10 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512e Sector
N8150-543
12TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 12 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512e Sector
NOTE:
- It can not be connected to the N8103-176/-177/-178/-188 RAID controller.
N8150-600
NOTE:
All drives within a RAID array should be of the same capacity. For 512e sector HDD, the supported operating systems of virtual machines on Hyper-V are:
- Windows Server 2008 R2 SP1 or later
- Windows 7 SP1 or later
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 30
4.3.7 Non-hot plug 3.5-inch Drives (1)
Category
Product Name / Description
Part Number
Drive
4slots available
SATA HDD (512n)
500GB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-526
1TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-514
2TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-515
3TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-516
4TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-517
NOTE:
All drives within a RAID array should be of the same capacity. Embedded SATA RAID Controller does not support RAID 10 configured with 2TB or more HDDs.
4.3.8 Non-hot plug 3.5-inch Drives (2)
Category
Product Name / Description
Part Number
Drive
4slots available
SATA HDD (512n)
500GB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-526
1TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-514
2TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-515
3TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-516
4TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-517
SATA HDD (512e)
6TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 6 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512e sector
N8150-538
8TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x8 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512e Sector
N8150-539
10TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x10 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512e Sector
N8150-542
12TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x12 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512e Sector
NOTE:
- It can not be connected to the N8103-176/-177/-178/-188 RAID controller.
N8150-601
NOTE:
Embedded SATA RAID Controller does not support RAID 10 configured with 2TB or more HDDs. For 512e sector HDD, the supported operating systems of virtual machines on Hyper-V are:
- Windows Server 2008 R2 SP1 or later
- Windows 7 SP1 or later
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 31
5 Optical Drive
Category
Product Name / Description
Part Number
Internal
Internal Slim DVD-ROM drive
Slim DVD-ROM drive DVD read speed: 8x (DVD-ROM / DVD-R / DVD-RW) CD read speed: 24x (CD-ROM / CD-R/RW)
N8151-134
Internal DVD Super Multi Drive
Slim DVD Super Multi drive, not including writing software DVD Read speed: 8x (DVD-R / DVD-RW / DVD-R DL / DVD+R / DVD+RW / DVD+R DL / DVD-ROM) DVD-RAM read speed: 5x CD read speed: 24x (CD-ROM / CD-R/RW)
NOTE:
- Not supported for Linux or VMware.
N8151-135F
External
External DVD Dual drive
DVD Dual drive, Bus powered, 1.5A required, not including writing software
N8160-101F
NOTE:
An optical drive is required for maintenance and OS installation. Up to 1 optical drive can be connected.
6 Flash FDD
Choose the Flash FDD if you need to prepare an alternative device for a floppy drive.
Product Name / Description
Part Number
Flash FDD
USB flash emulating USB floppy disk, Native capacity 1.44 MB
N8160-96
NOTE:
Up to one derive can be connected Not supported when VMware is running on the server.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 32
7 Internal RDX / LTO Drives
7.1 RDX/LTO Drive Selection
Refer to the section in accordance with your type of tape drives:
RDX: Refer to 7.2.1 LTO: Refer to 7.2.2
NOTE:
Tape devices cannot be directly connected to VMware ESXi servers. For an ESXi environment, it is recommended to connect
and configure an additional backup server via network.
7.2 RDX/LTO Configuration
7.2.1 RDX Drive
Category
Product Name / Description
Part Number
Controller
Internal USB Controller
1 x USB port
(Standard)
Cable
Required
Internal USB cable
1x Internal USB3.0 to 1x USB 3.0 device
K410-276(00)
Drive
1 drive available
Internal RDX (USB)
NOTE:
- Not supported for VMware.
N8151-125
7.2.2 LTO Drive
Category
Product Name / Description
Part Number
Controller
Required
SAS Controller
Broadcom SAS9212-4i4e Host Bus Adapter 6Gbps SAS, Int. 4, Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8
N8103-142
Cable
Required
Internal SAS Cable
1x 7-pin Single SATA to 1x SFF-8482 SAS
K410-217(00)
Drive
1 drive available
Internal LTO (SAS)
LTO4, Half height, Native capacity 800 GB
N8151-127
Internal LTO (SAS)
LTO5, Half height, Native capacity 1.5 TB
N8151-128
Internal LTO (SAS)
LTO6, Half height, Native capacity 2.5 TB
N8151-129
Internal LTO (SAS)
LTO7, Half height, Native capacity 6 TB
N8151-136
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 33
8 PCI Card
Please refer to Supported PCI cards and Installable Slots with regard to the position of PCI slot which can mount PCI card supported.
8.1 Network Interface Controller
Category
Product Name / Description
Part Number
Adapter
GbE
1000BASE-T Adapter
Broadcom ® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x1
N8104-150
Dual Port 1000BASE-T Adapter
Broadcom ® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x1
N8104-151
Quad Port 1000BASE-T Adapter
Broadcom ® BCM5719 Gigabit Ethernet Controller PCIe 2.0 x4
NOTE:
- Network cables with RJ-45 plug covers cannot be used.
N8104-152
10GbE
10GBASE SFP+ Adapter (SFP+/2ch)
Qlogic® NetXtreme II BCM57810 10G SFP+ Dual Port Network Interface Card PCIe 2.0 x8
NOTE:
- N8104-129 SFP+ Module is required to connect with an optical cable.
- Up to two SFP+ Modules can be installed.
- Up to two adapters can be installed.
N8104-149
Dual Port 10GBASE-T Adapter
Intel X550-BT2 PCIe 3.0 x4
N8104-157
SFP+ Module
SFP+ Module (10G-SR)
1 x SFP+ Module for N8104-149
N8104-129
NIC Teaming feature – NIC Teaming and bonding features
See the table below for supported network interfaces and OS combinations. Windows Server 2012 or later and Linux support teaming with bonding function supported by OS.
Network Interface
Team
OS
1GbE NIC
Embedded 1GbE NIC and N8104-150/-151/-152
Up to four teams per one system Up to four ports per one team
Windows Server 2012 Windows Server 2012 R2 Windows Server 2016 Red Hat Enterprise Linux
10GbE NIC
N8104-149
Up to two teams per one system Up to two ports per one team
Windows Server 2012 Windows Server 2012 R2 Windows Server 2016 Red Hat Enterprise Linux
10GbE NIC
N8104-157
Up to one teams per one system Up to two ports per one team
Windows Server 2012 Windows Server 2012 R2 Windows Server 2016 Red Hat Enterprise Linux
NOTE:
The network interfaces for a teaming must be the same. When 10GbE and 1GbE LAN teams are mixed, the teams must be up to four per one system.
Using iSCSI
See the table below for supported network interfaces and OS combinations.
Category
Network Interface
Operating Systems
1GbE
Embedded 1GbE NIC/ N8104-150/-151/-152
Windows Server 2012, Windows Server 2012 R2, Windows Server 2016, Red Hat Enterprise Linux 7, VMware
10GbE
N8104-149
Windows Server 2012, Windows Server 2012 R2, Windows Server 2016, Red Hat Enterprise Linux 7, VMware
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 34
Category
Network Interface
Operating Systems
N8104-157
Windows Server 2012, Windows Server 2012 R2, Windows Server 2016, Red Hat Enterprise Linux 7, VMware
NOTE:
NIC Teaming feature is not supported on iSCSI interfaces.
8.2 SAS Controller
Product Name / Description
Part Number
SAS Controller
Broadcom SAS9212-4i4e Host Bus Adapter 6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8
N8103-142
SAS Controller
Broadcom SAS9300-8e Host Bus Adapter 12Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 3.0 x8
N8103-184
8.3 Graphics Accelerator
Product Name / Description
Part Number
Graphics Accelerator
NVIDIA NVS 315, PCI Express 2.0 (x16) 1x DVI-VGA connector, DMS-59-DVI-I branch cable included
N8105-48
NOTE:
The standard VGA connector cannot be used when this option is installed. The remote KVM feature is not supported when this option is installed.
8.4 Serial Port Adapter
Product Name / Description
Part Number
Serial Port Adapter
Serial port fixed to PCI bracket
N8117-01A
NOTE:
Up to one Serial Port Adapter can be installed.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 35
9 Other Add-in Components
9.1 Fan Kit
Product Name / Description
Part Number
Non-redundant Fan Kit
Non-hot plug cooling fan for T110i
(Standard)
Non-redundant Power Supply Fan
Non-hot plug cooling fan for T110i
NOTE:
- It can be installed only when the non-redundant power supply n8181-177 is installed.
- If you select N8181-177 power supply unit and have a RAID controller, make sure to arrange it.
- If you use the n8181-146f High temperature resistant kit with a redundant Power model (N8100-
2332F), you need n8181-178 non-redundant Power Supply fan.
- N8146-96 (with sensor) or n8146-97 tower model for the tower model, please be sure to arrange for the clogging detection sensor.
N8181-178
9.2 Trusted Platform Module Kit
Product Name / Description
Part Number
Trusted Platform Module Kit
TPM 2.0 module
NOTE:
- Supported for Windows Server 2012 or later only.
N8115-23A
NOTE:
The kit is not available in China. The kit is not removable after attachment. "TPM Support" in BIOS setup menu must be activated prior to use of this kit. To use Windows BitLocker drive encryption, be sure to keep the "recovery password" of BitLocker function. The recovery
password is required to restore data for hardware replacement during a system error.
9.3 Internal Flash Memory
Product Name / Description
Part Number
VMware ESXi support kit Internal USB flash memory to install VMware ESXi system
N8106-013
NOTE:
The kit does not include VMware ESXi installation media and license.
9.4 High Temperature Support Option
Product Name / Description
Part Number
High temperature resistant Kit
Required for high temperature operation over 40°C (up to 48°C)
N8181-146F
NOTE:
To apply this option, there are some configuration limitations below.
Required System Configuration:
Internal RDX or LTO must not be installed.
9.5 Input Devices
Product Name / Description
Part Number
Keyboard
1 x 104-keys USB keyboard
N8170-25
USB Optical Mouse
1 x USB Mouse, 2-button, Optical with wheel
N8170-22
NOTE:
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 36
Keyboard and mouse are not included in the base models. Please order separately if necessary.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 37
10 Add-on Components
10.1 Server Management License
The server integrates the EXPRESSSCOPE Engine 3 as standard. Refer to Server Management for the standard management features. For more extensive remote KVM and remote media features, choose the following kit.
Product Name / Description
Part Number
Remote KVM and Media License Kit
License for one server. Remote KVM and remote media are enabled regardless of OS status. Remote KVM: Displays a graphics console on the web browser of the remote terminal (PC/server). Controls keyboard and mouse via the remote terminals' web browser Remote media: Enables the user to use the CD / DVD / FD / Flash memory of the remote terminals (PC/server) as if
accessing the local drives.
N8115-04
NOTE:
Remote KVM and remote media features are not available for virtual machines.
10.2 Dust Proof Kit
The server supports the dust resistant feature. Choose the following kit to install the system in dusty places.
Category
Product Name / Description
Part Number
Front Bezel
Dust Proof Bezel
Including 1 set of dust proof filter
N8146-71
Filter
Dust proof filter (5 pcs.)
For N8146-71 Dust Proof filter Removal capacity of particles : Up to 1 μm-sized
N8147-27
10.3 Rack Conversion Kit
The following rack conversion kit is required to install the server into a 19-inch rack system:
Product Name / Description
Part Number
Rack Conversion Kit
Convert to 4U form factor
N8143-93
10.4 Medium and Cartridge
Category
Product Name
Drive supported
Part Number
RDX
HDD
RDX Cartridge (500GB)
N8151-125
N8153-02
RDX Cartridge (1TB)
N8151-125
N8153-03
RDX Cartridge (2TB)
N8151-125
N8153-09
RDX Cartridge (3TB)
N8151-125
N8153-10
RDX Cartridge (4TB)
N8151-125
N8153-11
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 38
References
Boot Mode Setting
The server supports Legacy mode and UEFI mode (default) as an OS Boot Mode. See the table below for the Boot Mode and X2APIC setting for each Operating System. As the default settings at the factory, UEFI mode is set as OS Boot mode and X2APIC is enabled. Refer to the User’s Guide and change the settings before installing an Operating System requiring Legacy Mode.
Operating System
Supported Boot Mode
Supported X2APIC Setting
Windows Server 2012
UEFI
Enabled
Windows Server 2012 R2
UEFI
Enabled
Windows Server 2016
UEFI
Enabled
Red Hat Enterprise Linux 7
UEFI
Enabled
VMware ESXi 6.0 Update3
UEFI
Enabled
VMware ESXi 6.5
UEFI
Enabled
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 39
Server Management
The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system management features listed in the table below.
Standard
With Remote KVM and Media License kit
Hardware monitoring
Temperature/hard drive1/fan/voltage/power consumption/ System LAN/degeneration/ (memory/hard drive1)


Hardware configuration information collection


Hardware event log collection


Boot monitoring
BIOS/POST stall, Booting, OS stall, shutdown
3
3
Alerting
HW error, Boot error and OS panic (by SNMP, E-Mail)


Remote KVM (via LAN)
POST/BIOS setup, ROM utility
2

Panic screen, Boot screen
2,4,5

CUI-based screen (OS console)
2,5

GUI-based screen (OS console)
-

Remote Screen Video Capture
-

Remote control (via LAN)
Remote reset/power on-off/ dump


Remote Power Capping


BIOS/BMC FW update


Remote BIOS setup(partial configuration only)


OS shutdown
3
3
Remote media (CD/DVD/FD/USB)
-

CLP (Command Line Protocol) (DMTF compliant)


Remote control via Web browser (multi user login at the same time)


Scheduling (without UPS, require NEC ESMPRO Manager)
3
3
BIOS setting by using XML file


Maintenance
EXPRESSSCOPE® Profile key (Backup/restore BIOS/BMC setup information)


Others
Set automatic IP address via DNS/DHCP


LDAP/Active Directory verification/user control


Clock synchronization of main unit and the RTC


Access log collection


Industry Standard
IPMI support
2.0
2.0
1
The feature is not supported on non-hot plug 3.5-inch drive.
2
The optional serial port is not available for the feature.
3
The feature is not supported on VMware systems.
4
Monitoring boot screens is not supported on VMware systems.
5
In VMware systems, only the direct console user interface is supported.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 40
OS Support Matrix for PCI Cards and Embedded Controllers
Part Number
Product Name
WS 201
6
WS 2012 R2 WS 2012 RHEL 7 RHEL 6 x64 ESXi 6.5 ESXi 6.0
-
Embedded SATA non-RAID Controller

-
Embedded SATA RAID Controller

- - -
- - Embedded 1GbE NIC

N8103-188
RAID Controller (RAID 0/1)

N8103-176
RAID Controller (1GB, RAID 0/1)

N8103-177
RAID Controller (1GB, RAID 0/1/5/6)

N8103-178
RAID Controller (2GB, RAID 0/1/5/6)

N8103-205
RAID Controller (2GB, RAID 0/1/5/6)

-
- -
N8103-206
RAID Controller (2GB, RAID 0/1, WT/WB)

-
- -
N8103-207
RAID Controller (2GB, RAID 0/1/5/6, WT/WB)

-
- -
N8103-208
RAID Controller (4GB, RAID 0/1/5/6)

-
- -
N8103-210
RAID Controller (2GB, RAID 0/1, WT)

-
- -
N8103-211
RAID Controller (2GB, RAID 0/1/5/6, WT)

-
- -
N8105-48
Graphics Accelerator

- - - - N8104-157
Dual Port 10GBASE-T Adapter

N8104-149
10GBASE SFP+ Adapter (SFP+/2ch)

N8103-184
SAS Controller
-


N8103-142
SAS Controller

N8104-152
Quad Port 1000BASE-T Adapter

N8104-151
Dual Port 1000BASE-T Adapter

N8104-150
1000BASE-T Adapter

Supported PCI cards and Installable Slots
Slots
Part Number
Product Name
#1
#2
#3
#4
N8103-188
RAID Controller (RAID 0/1)
- - -
(1)
N8103-176
RAID Controller (1GB, RAID 0/1)
- - -
(1)
N8103-177
RAID Controller (1GB, RAID 0/1/5/6)
- - -
(1)
N8103-178
RAID Controller (2GB, RAID 0/1/5/6)
- - -
(1)
N8103-205
RAID Controller (2GB, RAID 0/1/5/6)
- - -
(1)
N8103-206
RAID Controller (2GB, RAID 0/1, WT/WB)
- - -
(1)
N8103-207
RAID Controller (2GB, RAID 0/1/5/6, WT/WB)
- - -
(1)
N8103-208
RAID Controller (4GB, RAID 0/1/5/6)
- - -
(1)
N8103-210
RAID Controller (2GB, RAID 0/1, WT)
- - -
(1)
N8103-211
RAID Controller (2GB, RAID 0/1/5/6, WT)
- - -
(1)
N8105-48
Graphics Accelerator
- - (1)
-
N8104-157
Dual Port 10GBASE-T Adapter
- - (1)
(2)
N8104-149
10GBASE SFP+ Adapter (SFP+/2ch)
- - (1)
(2)
N8103-184
SAS Controller
- - (1)
(2)
N8103-142
SAS Controller
-
(3)
(1)
(2)
N8104-152
Quad Port 1000BASE-T Adapter
(1)
(3) - (2)
N8104-151
Dual Port 1000BASE-T Adapter
(2)
(4)
(1)
(3)
N8104-150
1000BASE-T Adapter
(2)
(4)
(1)
(3)
N8118-307
Dual M.2 SATA Mount Kit
(1)
(2)
(3)
(4)
N8117-01A
Serial Port Adapter
(2)
(4)
(1)
(3)
NOTE:
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 41
The number between parentheses shows the population priority (recommendation). For example, install N8103-176 in the slot
#4 and N8104-157 in the slot #3 when you have those cards.
There are PCI slot limitations depending on the processor and operating system. Please refer to the following and be careful to
choose a processor and PCI cards.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 42
PCI slot limitations
See the table below for the limitations on installing PCI cards (due to the number of interrupts that can be processed in the system) depending on the installed processor.
Processor
RAID controller required
PCI slot limitations
Celeron G3930
Yes
Do not install the following PCI cards.
N8103-184 SAS Controller N8104-152 Quad Port 1000BASE-T Adapter N8104-157 Dual Port 10GBASE-T Adapter N8104-149 10GBASE SFP+ Adapter (SFP+/2ch) N8104-151 Dual Port 1000BASE-T Adapter N8104-150 1000BASE-T Adapter
No limitations for other cards.
No
Up to one of either N8103-184 SAS Controller or N8104-152 Quad
Port 1000BASE-T Adapter can be installed and up to one card from the following can be installed. Then, no limitations for other cards. N8104-157 Dual Port 10GBASE-T Adapter N8104-149 10GBASE SFP+ Adapter (SFP+/2ch) N8104-151 Dual Port 1000BASE-T Adapter N8104-150 1000BASE-T Adapter
No limitations when N8103-184 SAS Controller or N8104-152
Quad Port 1000BASE-T Adapter is not installed.
Pentium G4560 Core i3-7300 Xeon E3-1220v6 Xeon E3-1225v6
Yes
Up to two cards from the following can be installed.
N8103-184 SAS Controller N8104-152 Quad Port 1000BASE-T Adapter
No limitations for other cards.
No
Up to one card of N8103-184 SAS Controller can be installed.
No limitations for other cards.
Other processors
-
No limitations
PCI slot limitations for VMware
Do not install N8104-152 Quad Port 1000BASE-T Adapter when any of the following cards is installed.
N8104-157 Dual Port 10GBASE-T Adapter N8104-149 10GBASE SFP+ Adapter (SFP+/2ch)
When N8104-152 Quad Port 1000BASE-T Adapter is installed, the number of installable N8104-150/-151 is limited up to one. For the configuration limitation for VMware ESXi, refer to the following documents.
VMware ESXi6.0
https://www.vmware.com/pdf/vsphere6/r60/vsphere-60-configuration-maximums.pdf
VMware ESXi6.5
https://www.vmware.com/pdf/vsphere6/r65/vsphere-65-configuration-maximums.pdf
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 43
Secure Boot Mode
This server supports Secure Boot. It is supported with UEFI Boot mode and protects the security by only allowing software programs with digital signature to run. The supported operating systems, software, and boot devices are below. The default setting of Secure Boot is disabled. Keep the setting disabled to use other operating systems and/or software.
Supported OS and Software for Secure Boot Mode
Operating System
Supported Boot Mode
Secure Boot Mode
Windows Server 2012
UEFI
Windows Server 2012 R2
UEFI
Windows Server 2016
UEFI
Software Related to Boot
Supported Boot Mode
Secure Boot Mode
System Diagnostics Utility
UEFI
EXPRESSBUILDER
UEFI
Supported Boot Device for Secure Boot Mode
Supported Boot Device
Part Number
RAID controller (RAID0/1)
N8103-188 N8103-205
RAID controller (1GB, RAID0/1)
N8103-176
RAID controller (2GB, RAID0/1)
N8103-206 N8103-210
RAID controller (1GB, RAID0/1/5/6)
N8103-177
RAID controller (2GB, RAID0/1/5/6)
N8103-178 N8103-207 N8103-211
RAID controller (2GB, RAID0/1/5/6)
N8103-179
RAID controller (4GB, RAID0/1/5/6)
N8103-208
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 44
Copyright Notice and Liability Disclaimer
The information contained herein is subject to change without notice.
Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries
Intel, Xeon and Pentium are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries.
Linux is a trademark of Linus Torvalds. Red Hat is a registered trademark of Red Hat, Inc. in the U.S.
All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders.
NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less. The USB interface is not guaranteed to work properly for all USB devices.
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110i
NEC Corporation Revision 7.0 – June 2018 45
Revision History
Revision
Date
Description
7.0
June 25, 2018
New products added:
RAID Controller (2GB, RAID 0/1/5/6) / N8103-205
RAID Controller (2GB, RAID 0/1, WT/WB) / N8103-206
RAID Controller (2GB, RAID 0/1/5/6, WT/WB) / N8103-207
RAID Controller (4GB, RAID 0/1/5/6) / N8103-208
RAID Controller (2GB, RAID 0/1, WT) / N8103-210
RAID Controller (2GB, RAID 0/1/5/6, WT) / N8103-211
Flash Backup Unit / N8103-209
900GB 15K Hot Plug 2.5-inch SAS HDD / N8150-586
2.4TB 10K Hot Plug 2.5-inch SAS HDD / N8150-599
12TB 7.2K Hot Plug 3.5-inch SATA HDD / N8150-600
12TB 7.2K non-Hot Plug 3.5-inch SATA HDD / N8150-601
RAID LED CABLE / K410-444(00)
6.0
June 6, 2018
New products added:
NEC Express5800/T110i / N8100-2707F
Non-redundant Power Supply Fan / N8181-178
5.0
April 11, 2018
Discontinued product deleted:
NEC Express5800/T110i / N8100-2533F
4GB DDR4-2400 UNB Memory Kit / N8102-700F
Non-redundant Power Supply Fan / N8181-132F
Product code changed:
Trusted Platform Module Kit / N8115-23A
4.0
December 22, 2017
Others:
Dust Proof Kit and related description added
3.0
August 24, 2017
New products added:
200GB Hot Plug 2.5-inch SATA SSD / N8150-779
400GB Hot Plug 2.5-inch SATA SSD/ N8150-780
800GB Hot Plug 2.5-inch SATA SSD/ N8150-781
200GB Hot Plug 2.5-inch SATA SSD / N8150-782
400GB Hot Plug 2.5-inch SATA SSD / N8150-783
800GB Hot Plug 2.5-inch SATA SSD / N8150-784
1.6TB Hot Plug 2.5-inch SATA SSD / N8150-785
Discontinued product deleted:
200GB Hot Plug 2.5-inch SATA SSD / N8150-725
400GB Hot Plug 2.5-inch SATA SSD/ N8150-726
800GB Hot Plug 2.5-inch SATA SSD/ N8150-727
200GB Hot Plug 2.5-inch SATA SSD / N8150-732
400GB Hot Plug 2.5-inch SATA SSD / N8150-733
800GB Hot Plug 2.5-inch SATA SSD / N8150-734
1.6TB Hot Plug 2.5-inch SATA SSD / N8150-735
Others:
Removed the description of the Endurance of SSD
2.0
June 6, 2017
New products added:
120GB M.2 SATA SSD / N8150-736
Dual M.2 SATA Drive Installation Kit / N8118-307
Graphics Accelerator / N8105-48
Others:
Removed support information related to Windows Server 2008 R2
1.1
April 20, 2017
Others:
Dust Proof Kit and related description deleted
1.0
April 19, 2017
Initial release
Loading...