NEC Express5800-R110d-1E Appendix

Mark
Description
Appendix C : Logs/Events
The list of log and event , alert messages that Universal RAID Utility logs to RAID Log and OS Log.
[Event Source, Alert Type]
Source Name of Event Log (only Windows) : raidsrv Alert Type : URAIDUTL
[Log]
R Universal RAID Utility logs this event to RAID Log.
O Universal RAID Utility logs this event to OS log.
[Alert]
Mark Description
M and MA Universal RAID Utility send this event to NEC ESMPRO Manager as alert.
[
Address
The [ Address ] description is different from the category of event.
] description in [Description]
Category of Event Type Description
RAID Controller Battery
Physical Device 2 [CTRL:%1(ID=%2) PD:%3(ID=%4 ENC=%5 SLT=%6) %7%8]
Logical Drive 3 [CTRL:%1(ID=%2) LD:%3(ID=%4)]
Enclosure 4 [CTRL:%1(ID=%2) ENC:%3]
Power Supply Unit in Enclosure 5 [CTRL:%1(ID=%2) ENC:%3 POW:%4]
Fan Unit in Enclosure 6 [CTRL:%1(ID=%2) ENC:%3 FAN:%4]
1 [CTRL:%1(ID=%2)]
%1 : Number of RAID Controller %2 : ID of RAID Controller
%1 : Number of RAID Controller %2 : ID of RAID Controller %3 : Number of Physical Device %4 : ID of Physical Device %5 : Enclosure Number of Physical Device %6 : Slot Number of Physical Device %7 : Vendor and Model of Physical Device %8 : Firmware Version of Physical Device
%1 : Number of RAID Controller %2 : ID of RAID Controller %3 : Number of Logical Drive %4 : ID of Logical Drive
%1 : Number of RAID Controller %2 : ID of RAID Controller %3 : Number of Enclosure
%1 : Number of RAID Controller %2 : ID of RAID Controller %3 : Number of Enclosure %4 : Number of Power Supply Unit
%1 : Number of RAID Controller %2 : ID of RAID Controller %3 : Number of Enclosure %4 : Number of Fan Unit
1
[priority, facility]
The messages of Universal RAID Utility have the following priority and facility on Linux or VMware ESX.
kind priority facility
information info daemon
warning warning daemon
error err daemon
2
Event ID
0204
Information
[Address Type 1 ] The Consistency Check Priority of RAID
R
0211
Warning
[Address Type 1 ] A Warning Error happened to RAID
RO
M
RAID Controller Warning
Please check the RAID Controller. If some kind of
0213
Information
[Address Type 1 ] Patrol Read was paused.
R
(hex digit)
0201
(400000C9)
0202
(400000CA)
0203
(400000CB)
Severity Description Log Alert Summary Deal Method
Information [Address Type 1 ] The buzzer of RAID Controller is enable. R
Information [Address Type 1 ] The buzzer of RAID Controller is disable. R
Information [Address Type 1 ] The Rebuild Priority of RAID Controller was
changed. (Value : %1)
R
(400000CC)
0205
(400000CD)
0206
(400000CE)
0207
(400000CF)
0208
(400000D0)
0209
(400000D1)
0210
(400000D2)
(800000D3)
0212
(C00000D4)
(400000D5)
0214
(400000D6)
0215
(400000D7)
0216
(400000D8)
0217
(C00000D9)
0301
(4000012D)
Controller was changed. (Value: %1)
Information [Address Type 1 ] The Initialize Priority of RAID Controller
was changed. (Value : %1)
Information [Address Type 1 ] Auto Patrol Read function is enable. R
Information [Address Type 1 ] Auto Patrol Read function is disable. R
Information [Address Type 1 ] A Patrol Read Priority of RAID Controller
was changed. (Value : %1)
Information [Address Type 1 ] Patrol Read was started. R
Information [Address Type 1 ] Patrol Read completed. R
Controller. Detail : %1
Fatal [Address Type 1 ] A Fatal Error happened to RAID Controller.
Detail : %1
Information [Address Type 1 ] Patrol Read was resumed. R
Information [Address Type 1 ] Patrol Read was queued. R
Information [Address Type 1 ] Patrol Read was stopped. R
Fatal [Address Type 1 ] Patrol Read failed. RO MA Patrol Read Failed Please disable the setting of Patrol Read and then
Information [Address Type 2 ] Physical Device is Online. RO M Physical Device Online None
R
R
problem happens to the RAID Controller repeatedly, please replace it.
RO MA RAID Controller Fatal Please replace the RAID Controller.
enable it to retry Patrol Read. If Patrol Read fails again, the RAID System may have some problems. Please deal with the problem of the RAID System and retry Patrol Read.
3
Loading...
+ 5 hidden pages