Power Supply Unit in Enclosure 5 [CTRL:%1(ID=%2) ENC:%3 POW:%4]
Fan Unit in Enclosure 6 [CTRL:%1(ID=%2) ENC:%3 FAN:%4]
1 [CTRL:%1(ID=%2)]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Physical Device
%4 : ID of Physical Device
%5 : Enclosure Number of Physical Device
%6 : Slot Number of Physical Device
%7 : Vendor and Model of Physical Device
%8 : Firmware Version of Physical Device
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Logical Drive
%4 : ID of Logical Drive
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Enclosure
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Enclosure
%4 : Number of Power Supply Unit
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Enclosure
%4 : Number of Fan Unit
1
[priority, facility]
The messages of Universal RAID Utility have the following priority and facility on Linux or VMware ESX.
kind priority facility
information info daemon
warning warning daemon
error err daemon
2
Event ID
0204
Information
[Address Type 1 ] The Consistency Check Priority of RAID
R
0211
Warning
[Address Type 1 ] A Warning Error happened to RAID
Information [Address Type 1 ] The buzzer of RAID Controller is enable. R
Information [Address Type 1 ] The buzzer of RAID Controller is disable. R
Information [Address Type 1 ] The Rebuild Priority of RAID Controller was
changed. (Value : %1)
R
(400000CC)
0205
(400000CD)
0206
(400000CE)
0207
(400000CF)
0208
(400000D0)
0209
(400000D1)
0210
(400000D2)
(800000D3)
0212
(C00000D4)
(400000D5)
0214
(400000D6)
0215
(400000D7)
0216
(400000D8)
0217
(C00000D9)
0301
(4000012D)
Controller was changed. (Value: %1)
Information [Address Type 1 ] The Initialize Priority of RAID Controller
was changed. (Value : %1)
Information [Address Type 1 ] Auto Patrol Read function is enable. R
Information [Address Type 1 ] Auto Patrol Read function is disable. R
Information [Address Type 1 ] A Patrol Read Priority of RAID Controller
was changed. (Value : %1)
Information [Address Type 1 ] Patrol Read was started. R
Information [Address Type 1 ] Patrol Read completed. R
Controller. Detail : %1
Fatal [Address Type 1 ] A Fatal Error happened to RAID Controller.
Detail : %1
Information [Address Type 1 ] Patrol Read was resumed. R
Information [Address Type 1 ] Patrol Read was queued. R
Information [Address Type 1 ] Patrol Read was stopped. R
Fatal [Address Type 1 ] Patrol Read failed. RO MA Patrol Read Failed Please disable the setting of Patrol Read and then
Information [Address Type 2 ] Physical Device is Online. RO M Physical Device Online None
R
R
problem happens to the RAID Controller repeatedly,
please replace it.
RO MA RAID Controller Fatal Please replace the RAID Controller.
enable it to retry Patrol Read. If Patrol Read fails again,
the RAID System may have some problems. Please deal
with the problem of the RAID System and retry Patrol
Read.
3
Event ID
0305
Warning
[Address Type 2 ] Detected S.M.A.R.T. Error.
RO
MA
S.M.A.R.T. Error
Please replace the Physical Device.
0313
Information
[Address Type 2 ] Global Hot Spare created.
R
A Fatal Error happened to Physical Device.
0320
Fatal
[Address Type 2 ] Medium Error was detected in Physical
RO
MA
Physical Device Medium
Please replace the Physical Device if too many errors
Fatal [Address Type 3 ] Data Inconsistency was detected in
Logical Drive by Consistency Check and corrected.
RO MA Data Inconsistency Error
Corrected
Please execute Consistency Check again when the load
of the system is low. If the error does not occur on the
second time of Consistency Check, the Physical Device
does not have any problems. If the same error occurs,
please replace the Physical Device for the preventive
maintenance (please be sure to ask NEC customer
service before the replacement to identify which
Physical Device has a failure). After replacing the
Physical Device, restore the backup data to the Logical
Drive.
Information [Address Type 3 ] Logical Drive was created. R
Information [Address Type 3 ] Logical Drive was deleted. R
Information [Address Type 3 ] The Cache Mode of Logical Drive was
RO M Cache Mode Changed None
changed. (Value : %1)
%1 : Changed value
*1
Information [Address Type 3 ] Background Initialization was started. R
Information [Address Type 3 ] Background Initialization completed. R
Warning [
] Background Initialization failed. RO MA Background Initialization
Failed
The RAID System may have some kind of problem.
Please deal with the problem of the RAID System.
Information [Address Type 3 ] Background Initialization was stopped. R
(C00001A6)
0423
(400001A7)
0424
(800001A8)
Information [Address Type 3 ] An error was detected in Logical Drive and
Warning [Address Type 3 ] A Warning Error happened to Logical
could not correct.
corrected.
Drive. Detail : %1
%1 : Detail Information
0425
(C00001A9)
Fatal [Address Type 3 ] A Fatal Error happened to Logical Drive.
Detail : %1
%1 : Detail information
0426
Information [Address Type 3 ] Initialization was paused. R
(400001AA)
0427
Information [Address Type 3 ] Initialization was resumed. R
(400001AB)
Uncorrectable Error
Drive and restore the backup data to it.
RO MA Logical Drive Corrected
Error
Please replace the Physical Device for the prevention of
failure(You need to ask it which Physical Device do you
replace). Next restore the backup data to the Logical
Drive after replacement of Physical Device.
RO M Logical Drive Warning
component has broken.
RO MA Logical Drive Fatal The RAID Controller and/or the Physical Device may
have some kind of problem. You need to ask it which
component has broken.
6
Event ID
0431
Information
[Address Type 3 ] Consistency Check was queued.
R
0504
Information
[Address Type 1 ] The temperature of Battery is normal.
RO
M
Battery Temperature
0509
Information
[Address Type 1 ] The voltage of Battery is normal.
RO
M
Battery Voltage Normal
None
Please check the Enclosure. If some kind of problem
dly, please deal with
0602
Fatal
[Address Type 4 ] A Fatal Error happened to Enclosure.
RO
MA
Enclosure Fatal
Please check the Enclosure. If some kind of problem
Please check the Fan Unit of the Enclosure. If some
Information [Address Type 3 ] Initialization was queued. R
Information [Address Type 3 ] Consistency Check was paused. R
Information [Address Type 3 ] Consistency Check was resumed. R
Information [Address Type 3 ] Background Initialization was paused. R
Information [Address Type 3 ] Background Initialization was resumed. R
Information [Address Type 3 ] Background Initialization was queued. R
Information [Address Type 1 ] Battery was detected. R
Warning [Address Type 1 ] Battery was disconnected. RO MA Battery Disconnect Please check the Battery. If some kind of problem
happen to the Battery repeatedly, please replace it.
Information [Address Type 1 ] Battery was replaced. R
(400001F8)
0505
(800001F9)
0506
(800001FA)
0507
(800001FB)
0508
(800001FC)
(400001FD)
0601
(80000259)
(C000025A)
0603
(8000025B)
Warning [Address Type 1 ] The temperature of Battery is high. RO M Battery Temperature High Please check the Battery. If some kind of problem
Warning [Address Type 1 ] The voltage of Battery is low. RO M Battery Voltage Low Please check the Battery. If some kind of problem
Warning [Address Type 1 ] A Fatal Error happened to Battery. RO MA Battery Fatal Please replace the Battery.
Warning [Address Type 1 ] The Battery state is unstable. RO
Warning [Address Type 4 ] A Warning Error happened to Enclosure. RO M Enclosure Warning
Warning [Address Type 4 ] The temperature of Enclosure is Warning
level.
Normal
RO MA Enclosure Temperature
Warning
7
happens to the Battery repeatedly, please replace it.
happens to the Battery repeatedly, please replace it.
happens to the Enclosure repeate
the problem of the Enclosure.
happens to the Enclosure repeatedly, please deal with
the problem of the Enclosure.
kind of problem happens to the Fan Unit, pleas
with the problem.
Event ID
Please check the Power Supply Unit of the Enclosure. If
Address Type 6
The temperature of Enclosure is Normal
0701
Information
[Address Type 1 ] The Configuration was cleared.
RO
M
Configuration Cleared
None
It became unable to manage the RAID System due to a fatal
Please solve the fatal error on operating system. This
event is reported by insufficient free memory space,
insufficient free disk space or any other causes. Please
Fatal [Address Type 4 ] The temperature of Enclosure is Fatal
level.
Warning [Address Type 5 ] An error happened to the Power Supply
Unit of Enclosure.
Warning [
Enclosure.
Information [Address Type 4 ]
level.
Information raidsrv Configuration
[CTRL:%1(ID=%2)] Vendor Product Firmware Version
[LD:%3(ID=%4)] RAID:RAIDlevel PD:X,Y,Z (count of LD
STS:Status
[PD:%5(ID=%6 ENC=%7 SLT=%8] Vendor/Model Firmware
Version STS:Status
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Logical Drive
%4 : ID of Logical Drive
%5 : Number of Physical Device
%6 : ID of Physical Device
%7 : Enclosure Number of Physical Device
%8 : Slot Number of Physical Device
X, Y, Z : Number of Physical Device used in Logical Drive.
There is not the STS of PD when the device type is not HDD
or HDD(SSD).
Fatal
error on the operating system.
] An error happened to the Fan Unit of
RO MA Enclosure Temperature
Fatal
RO MA Enclosure Power Supply
Unit Error
RO MA Enclosure Fan Unit Error Please check the Fan Unit of the Enclosure. If some
RO MA Enclosure Temperature
Normal
O
RO MA Operating System Fatal
Error
Please check the Fan Unit of the Enclosure. If some
kind of problem happens to the Fan Unit, please deal
with the problem.
some kind of problem happens to the Power Supply
Unit, please deal with the problem.
kind of problem happens to the Fan Unit, please deal
with the problem.
None
*1 : This item may not include in log message by the type of RAID Controller
refer Universal RAID Utility User's Guide for detail.
8
Loading...