N135WG CAP E
STICK ON CAPSULE VENT SWITCH AND MAGNET SET WITH END LEADS
DESCRIPTION
Nascom’s N135WG CAP VE Series is an extension our ground breaking CAP
switch. Never drill in windows or doors again. The switch and magnet are so
thin they will t between the window sill and sash. When surface mounted,
the smooth rounded edges and ultra-thin prole makes it almost disappear.
The CAP switch is designed to protect all nonferrous (e.g. wood, aluminum
and vinyl) doors and windows, in both residential and commercial settings.
The N135WG CAP VE, is the installer’s choice of contact conguration where
the requirements are surface mount and vent capability
FEATURES
• EURO DESIGN - ALMOST DISAPPEARS • 3M VHB (Very High Bond) DOUBLE SIDED TAPE
• 12” 24AWG ZIPCORD LEADS • ABS HOUSINGS
• WIDE GAP - N35 NdFeB RARE EARTH
ORDERING INFORMATION
CONTACT RATING
PART
NUMBER
COLOR
OPERATE
GAP
(in inches)
(Max DC/Peak AC Resistive)
SWITCHING CARRY
V I V I
CLOSED LOOP, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET:
N135WGB/ST CAPVE
N135WGG/ST CAPVE
N135WGT/ST CAPVE
N135WGW/ST CAPVE
BROWN
GREY
TAN
WHIITE
0.50 to 0.875 200 VDC 0.5 Amps 10vA 1.5 Amps 150 mOhms
STATIC
CONTACT
RESISTANCE
(50mV, 100mA)
WIRING SCHEMATIC
SWITCH
CONTACT
CLOSED LOOP,
NORMALLY OPEN CONTACT
Royne Industries LLC, dba NASCOM
|
P: 800.843.5530
|
F: 800.727.4041
|
www.nascominc.com
DWG No. 131125-20 Rev. 1
1
3.360
85.34
.200
5.08
.400
10.16
TOP
VIEW
FRONT
VIEW
RIGHT
VIEW
DIMENSIONS - IN [mm]
1.090
27.69
.200
5.08
.400
10.16
1.000
25.40
.195
4.95
.500
12.70
FRONT
VIEW
TOP
VIEW
RIGHT
VIEW
N135WG CAP E
STICK ON CAPSULE VENT SWITCH AND MAGNET SET WITH END LEADS
SWITCH
MAGNET
INSTALLATION INSTRUCTIONS
• Pre-t the switch and magnet in the desired location on the window.
• Clean the mounting surface area for both switch and magnet with alcohol and let dry.
• Remove the liner from the tape on the back of the switch and carefully position the switch on the window frame as close
as possible to the movable part of the window.
• Remove the liner from the tape on the back of the magnet and carefully align the magnet parallel with the switch on the
movable part of the window and as close to the window frame as possible , and aligned with the end of the switch. The
magnet should move parallel along the length of the switch as the window is opened. Use the larger magnet if extra gap
is needed, or if the offset between the widow frame and sash is greater than 3/16”.
• Apply rm pressure to the switch and magnet housing to ensure proper adhesion to the mounting surface.
• Connect the switch leads to the alarm system circuit. Caution! Hold wire leads, not the switch housing while cutting and
stripping to prevent damage to switch.
• Test alarm system for correct operation.
PART NUMBERING SYSTEM
N135WG
X ST/ XXXX
CAPVE
COLOR:
• B = BROWN
• G = GREY
• T = TAN
• W = WHITE
Royne Industries LLC, dba NASCOM
|
P: 800.843.5530
LEAD LENGTH (zero, 3 or 4 digits):
• Blank - 12 Inches
• All other lengths specied in Inches with 3
digits (e.g. 036 = 36 Inches)
|
F: 800.727.4041
|
www.nascominc.com
DWG No. 131125-20 Rev. 1
2