N122WG
1/4” STICK ON, BREAKOFF FLANGE, CENTER LEADS
DESCRIPTION
Nascom’s N122WG Series, 1/4” stick on contact, protects all nonferrous (e.g.
wood, aluminum and vinyl) doors and windows, in both residential and commercial settings.
The N122WG is the installer’s choice of contact conguration where excellent
air and side-to-side gap are required to prevent false alarms caused by shifting or warping doors and windows.
FEATURES
• BREAKOFF FLANGE • ENCAPSULATED HERMETICALLY SEALED CONTACTS
• 12” 22AWG WIRE LEADS • 3M VHB (Very High Bond) DOUBLE SIDED TAPE
• WIDE GAP - N35 NdFeB RARE EARTH MAGNET • ABS HOUSINGS
• LISTED TO UL634 STANDARD
ORDERING INFORMATION
CONTACT RATING
PART
NUMBER
COLOR
OPERATE
GAP
(in inches)
(Max DC/Peak AC Resistive)
SWITCHING CARRY
V I V I
CLOSED LOOP, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET:
N122WGSW/ST
N122WGB/ST
N122WGG/ST
N122WGT/ST
N122WGW/ST
SNOW WHITE
BROWN
GREY
TAN
WHITE
0.75 to 1.125 200 VDC 0.5 Amps 10vA 1.5 Amps 150 mOhms
OPEN LOOP, NORMALLY CLOSED, 1FB, SWITCH/MAGNET SET:
N122WGSW/STFB
N122WGB/STFB
N122WGG/STFB
N122WGT/STFB
N122WGW/STFB
SNOW WHITE
BROWN
GREY
TAN
WHITE
0.65 to 1.00
30 VDC 0.2 Amps 3vA 0.5 Amps 100 mOhms
STATIC
CONTACT
RESISTANCE
(50mV, 100mA)
Royne Industries LLC, dba NASCOM
|
P: 800.843.5530
|
F: 800.727.4041
|
www.nascominc.com
DWG No. 131118-01 Rev. 1
1
.350
8.89
.300
7.62
3M TAPE
1.025
26.04
1.332
33.83
.262
6.65
.500
12.70
11.250
285.75
TOP VIEW
FRONT VIEW
END VIEW
.350
8.89
.300
7.62
3M TAPE
1.025
26.04
1.332
33.83
.262
6.65
.500
12.70
FRONT VIEW
TOP VIEW
END VIEW
WIRING SCHEMATIC
N122WG
1/4” STICK ON, BREAKOFF FLANGE, CENTER LEADS
SWITCH
CONTACT
CLOSED LOOP,
NORMALLY OPEN CONTACT
DIMENSIONS - IN [mm]
SWITCH
SWITCH
CONTACT
OPEN LOOP,
NORMALLY CLOSED CONTACT
MAGNET
INSTALLATION INSTRUCTIONS
• Pre-t the switch and magnet in the desired location on the window.
• Clean the mounting surface area for both switch and magnet with alcohol and let dry.
• Remove the liner from the tape on the back of the switch and carefully position the switch on the window frame as close
as possible to the movable part of the window.
• Remove the liner from the tape on the back of the magnet and carefully align the magnet parallel with the switch on the
movable part of the window and as close to the window frame as possible.
• Apply rm pressure to the switch and magnet housing to ensure proper adhesion to the mounting surface.
• Connect the switch leads to the alarm system circuit. Caution! Hold wire leads, not the switch housing while cutting and
stripping to prevent damage to switch.
• Test alarm system for correct operation.
Royne Industries LLC, dba NASCOM
|
P: 800.843.5530
|
F: 800.727.4041
|
www.nascominc.com
DWG No. 131118-01 Rev. 1
2