THIS MANUAL INCLUDES FEATURES WHICH ARE ONLY AVAILABLE IN CONTROL PANEL
FIRMWARE VERSION 5 OR LATER.
CHANGES FROM PREVIOUS EDITION
The following changes have been made to this manual (WI1093C) since the last edition (WI1093B).
This version of the manual reflects the addition of two new NAPCO products:
•The Access Control system (ACM), which provides integrated access control to the burglary alarm functions of the
GEM-X255 control panel.
•The NAPCO NetLink™ system that allows the reporting of alarms over a TCP/IP based (Intranet or Internet) net-
work.
Page 30, new Keypad messages (System Troubles) added to accommodate the new ACM and NetLink™ systems.
•
Refer to accompanying GEM-X255 Programming Instructions (WI1092) for programming information.
NAPCO Security Systems, Inc.
333 Bayview Avenue, Amityville, New York 11701
For Sales and Repairs, call toll free: (800) 645-9445
For direct line to Technical Service, call toll free: (800) 645-9440
Internet: http://www.napcosecurity.com
WI1093C 3/04
Page 3
IMPORTANT NOTE
This manual supports the keypad programming of the GEM-X255 control panel with the NAPCO "classic" GEMRP1CAe2 keypad as well as the GEM-K1CA "K Series" keypad. The new "K Series" model offers the new STAY and
AWAY buttons with simplified functionality, along with the new MENU and ENTER buttons.
While the instructions in this manual are depicted using the GEM-K1CA keypad, the manual applies to both the "classic"
and the "K Series" keypads.
Program Mode
The
•
• The
A
D
button and the U button operate identically (in Program Mode) for both keypads.
is the same for both keypads--
button and the
R
button operate identically (in Program Mode) for both keypads.
only the button names have changed
, as follows:
!
• The
"
NEXT/YES
• The
"
PRIOR/NO
!
For consistency, it is recommended that all keypads either be all "classic" or all "K Series"--both keypad
types should not be used in one alarm system.
button and the button operate identically (in Program Mode) for both keypads. The words
button" are used in this manual.
button and the button operate identically (in Program Mode) for both keypads. The words
button" are used in this manual.
IMPORTANT NOTICE
GEM-X255 panel version 4 requires the use of the following version keypads:
!
GEM-RP1CAe2 Version 8, GEM-K1CA Version 8C
•
Upon entering program mode, the keypad display will flash the control panel firmware version, followed by
the keypad firmware version:
GEM-RP1CAe2: [048C]
GEM-K1CA: [048C]
L
NAPCO Security Systems
X
GEM-X255 Installation Instructions
Page 4
!
TABLE OF CONTENTS
WI1093C 3/04
CHANGES FROM PREVIOUS EDITION ........................ 2
IMPORTANT NOTE ......................................................... 3
Basic Zone Configuration .................................. 16
Expanded Zone Configuration .......................... 16
Refer to accompanying GEM-X255 Programming Instructions (WI1092) for programming information.
NOTE: THESE INSTRUCTIONS ARE INTENDED AND WRITTEN FOR PROFESSIONAL INSTALLATION PERSONNEL HAVING SUITABLE
TRAINING, EXPERIENCE AND INSTALLATION EQUIPMENT. IT IS RECOMMENDED THAT AFTER PROGRAMMING, THE ERROR CHECK
UTILITY OF THE PCD3000 (OR PCD-WINDOWS) DOWNLOADER SOFTWARE BE USED TO VERIFY THAT THE CONTROL PANEL PROGRAM CONTAINS NO ERRORS OR CONFLICTS WHICH MAY INHIBIT ITS INTENDED OPERATION.
GEM-X255 Installation Instructions
X
L
NAPCO Security Systems
WI1093C 3/04
Page 5
!
INTRODUCTION
GENERAL DESCRIPTION
NAPCO's Gemini GEM-X255 is a state-of-the-art microcomputer-based burglary and residential fire alarm control panel
of modular design. Integrally an 8-zone panel, it will support up to 255 zones with optional zone expansion modules,
wireless receiver modules and/or GEM-RP1CAe2/GEM-K1CA Keypads. Each panel includes an integral digital communicator.
The control panel features programmable area partitioning. That is, the system may be divided into up to 8 discrete multiple-zone areas, each allowing access by only those users programmed for their respective area(s).
Opening Suppression and Closing Suppression, available through Napco Quickloader software, suppress reporting
within programmed “windows of time”. Conversely, Exception Reporting can transmit a “fail to close report” if the panel
is not armed within programmed intervals and, similarly, a “fail to open report” if the panel is not disarmed within programmed intervals of time. Furthermore, the panel can be programmed to automatically arm either area at any time. A
log containing up to 800 events (accessible through Quickloader
a precision real-time clock. A detailed event history may be displayed at the computer, using NAPCO's PCD-Windows
Quickloader Software.
Keypads feature a liquid-crystal display for messages. In normal use, the LCD shows zone identification and system
status messages. Conventional LEDs and a sounder are also provided for annunciation.
Data may be quickly and easily downloaded to the control panel using a PC-compatible computer with NAPCO's PCDWindows Quickloader software and PCI2000 computer interface. Or, the panel may be programmed using the keypad in
its secondary mode of operation. In keypad programming modes (there are two: Dealer and User), the LCD shows
memory address, data values, programming prompts, and the alphanumeric characters required for entering up to 195
user codes and custom zone descriptions.
GEM-X255M
The standard GEM-X255 may be converted to the Mercantile “GEM-X255M” version with the optional H1217 accessory.
The H1217 kit includes the model H217 heavy-duty UL commercial enclosure, two tamper switches and tamper screws.
Note: Do not use Fire Zones in a Mercantile installation.
TM
software) monitors control-panel activity referenced to
NOTE: Failure to install and program as described in this manual for UL-listed systems voids the listing mark of Underwriters Laboratories, Inc.
FEATURES
! Eight end-of-line-resistor burglary zones programmable for Area, Exit/Entry Delay, Interior, Follower, Day Zone,
Chime, Fire options, Sensor Watch, Swinger Shutdown, Zone Anding and a variety of other features.
! Supports up to 96 zones using the keypad (255 with PCD-Windows software) with optional zone-expansion modules
and 4-zone keypads.
! Supports up to 96 individually coded users using the keypad (195 with PCD-Windows software), each with a pro-
grammable authority level.
Supports three on-board relay outputs and up to 96 external relay outputs.
!
Supports four keypad panics: Fire, Police, Auxiliary & Ambush.
!
Supports up to 8 independent area partitions.
!
Supports up to 8 separate keypad access control stations by up to 195 users.
!
Supports up to 64 separately-addressable X-10 devices with the GEM-X10KIT and PC04 interfaces.
!
English-language prompts & system status messages.
!
User-customized zone descriptions, re-programmable as required.
!
Supports 2-wire and 4-wire smoke detectors.
!
Reports alarms, restores and troubles by zone.
!
255 Event Schedule.
!
L
NAPCO Security Systems
X
GEM-X255 Installation Instructions
Page 6
!
800 Event Log.
!
Overview Mode permits monitoring and control of total system from one keypad.
!
Guard-Tour programmable for start time, tour length, and check points (tour stations).
!
Two programmable Entry Delay times.
!
Two Interior-Zone groups (when used with GEM-RP1CAe2 / GEM-K1CA keypads).
!
Dynamic battery test interrupts charging and places battery under load every four hours.
!
Chime by zone; programmable duration.
!
Non-volatile RAM retains memory during power losses.
!
Quickloader programmable.
!
Auto-Download Log.
!
Exclusive V.A.L.I.D. feature (Verifying Automatic Line-Integrity Diagnostic) reduces false alarms due to changes in
!
line resistance.
WI1093C 3/04
Communicator Features
Compatible with all major receiver formats, including BFSK, 4/2, Modem 2, SIA, 4/3/1, 4+2 Express and Point ID.
!
Rotary dial, TouchToneTM only, and TouchToneTM with Rotary backup.
!
! AC Failure Reporting with programmable report delay.
Supervised telephone line with programmable delay.
!
Pager capability.
!
! GEM-ACM1D and GEM-2D Access Control Modules provide integrated access control to the burglary alarm functions
of the GEM-X255 control panel.
Keypad Features
! English-language LCD display; LED and sounder annunciators.
Supports up to fifteen 4-wire keypads.
!
Access only capability.
!
! Provisions for fire, police, auxiliary and ambush panic alarms.
Integral 4-zone EZM included in each keypad (GEM-RP1CAe2/GEM-K1CA only).
!
Communicator Test to Central facilitates testing; Locate, Fault-Find and EZM-Locate diagnostics simplify trouble-
!
shooting.
PGM output.
!
! The NAPCO NetLink™ system allows the reporting of alarms over a TCP/IP based (Intranet or Internet) network
GEM-X255 Installation Instructions
X
L
NAPCO Security Systems
WI1093C 3/04
Page 7
SPECIFICATIONS
GEM-X255
Panel Dimensions: 12 3/8" x 13 7/8" x 3 ½" (H x W x D) without cover
Operating Temperature: 0-49°C (32-120°F)
Input Power: 16.5VAC via CLASS 2 Plug-In 40VA or 50VA Transformer
Loop Voltage: 10-13VDC
Loop Current: 2.4mA with 2.2K Ohm end-of-line resistor (Model EOL2.2K); 5mA for 2-wire smoke-detector zones
Loop Resistance: 300 Ohm max.; 50 Ohm for 2-wire smoke-detector zones
Relay Outputs (Burglary; Reset; Aux): Wet, 12Vdc, 1.2A max.; Dry (cut related jumper for dry contacts; see Wiring Dia-
gram), SPDT contacts 24Vdc, 2A, 0.6 PF
Auxiliary Power Output: 12Vdc regulated
Remote Power Output: 12Vdc regulated (for keypads)
Combined Standby Current (Remote Power + Aux. Power + Reset Relay Power): See following charts.
TRANSFORMER RECHARGEABLE
BATTERY
TRF11 (16.5 VAC, 40 VA) RBAT4 (12 VDC, 4 AH) N/A 750 mA 2.0 A N/A 4 Hours
TRF11 (16.5 VAC, 40 VA) RBAT6 (12 VDC, 6 AH) N/A 750 mA 2.0 A N/A 6 Hours
TRF11 (16.5 VAC, 40 VA)
TRF11 (16.5 VAC, 40 VA)
(3)
RBAT6 (12 VDC, 6 AH) PS3002 (13.2 VDC, 1.9 A) 750 mA 1.9 A
(3)
2 RBAT6 (12 VDC, 6 AH) PS3002 (13.2 VDC, 1.9 A) 750 mA
RESIDENTIAL FIRE, COMBINATION RESIDENTIAL FIRE & BURGLARY
TRANSFORMER RECHARGEABLE
RESIDENTIAL BURGLARY & COMMERCIAL BURGLARY
BATTERY
POWER
SUPPLY
STANDBY CURRENT
GEM-X255 COMBINED
STANDBY CURRENT
GEM-X255
COMBINED
GEM-X255
ALARM
CURRENT
GEM-X255
ALARM
CURRENT
(2)
1.9 A
STANDBY
TIME
PS3002 POWER
SUPPLY
STANDBY
CURRENT
1.2 A
STANDBY
TIME
(1)
1.4 A 4 Hours
4 Hours
Notes:
(1)
With 1 RBAT6 battery, GEM-X255 combined standby current + PS3002 standby current may not exceed 1.2A.
(2)
With 2 RBAT6 batteries, GEM-X255 combined standby current + alarm current may not exceed 1.9A.
TRF11 (16.5 VAC, 40 VA) RBAT7 (12 VDC, 7 AH) 150 mA 650 mA 24 Hours
GEM-RP1CAe2/GEM-K1CA: 100mA; 35mA if backlighting is disabled (cut W1, W2 & W3)
PGM Output: 5mA, 12V Special Application
Maximum Number of Keypads: 15
Maximum Wiring Length for each run (#22AWG): 1000' divided by total number of keypads and EZMs on run
Keypad Dimensions: 4 ¼" x 5 ¾" x 1" (H x W x D); 11.1cm
ORDERING INFORMATION
System Components
GEM-X255: Residential UL-Listed Burg Control Panel.
GEM-RP1CAe2/GEM-K1CA: 32-Character LCD Burg & Residential Fire Keypad with 4 EOL Resistor Supervised
Household Burglar Alarm System Units: UL1023
Household Fire Warning System Units: UL985
Local Burglar Alarm Units and Systems: UL609
Central Station Burglar Alarm Units: UL1610
Police Station Alarm Units: UL365
Security Industry Association (SIA) False Alarm Reduction
Standard CP-01
COMPATIBLE UL-LISTED DEVICES
Refer to the following list of recommended devices.
Bells:
Ademco AD8-12; AD10-12
Amseco MBL-8/12V; MBL-10/12V
Wheelock 46T-G4-12-R*; 46T-G6-12-R; 46T-G10-12-R
Hochiki America AL-VB-1012*; AL-MB-612*
*Not for Household Fire applications (<85dB at 10')
Grade-A Bell:
Ademco AB-12 Bell in Box
Horns:
Wheelock 34T-12-R; MT-12/24; MT4-12/24; MIZ-12
Faraday 6120-0-0-12-DC*
Federal Signal 450E-24
Hochiki America AL-FH-12M*
*Not for Household Fire applications (<85dB at 10')
Mini-Horn:
Federal Signal 460-024-R (red); -W (white); -BG (beige)
Chimes:
Wheelock CH-CF1-12; CH-DF1-12 (both for private-mode sig-
nalling only)
Strobes:
System Sensor SS1215ADA; SS1215ADAB
Wheelock LS12
Strobe/Horns:
Wheelock 7002T-12-W-FR; 7001T-12-W-FR; V7001T-12-W-FR
Gentex SHG-12H
System Sensor MASS1215ADA; MASS1215ADAB
Wheelock 46T-G6-12-WS-12-HF-R; 46T-G10-12-WS-12-HF-R
Transformers:
Basler Electric BE116240CAA 40VA; BE116250CAA 50 VA
GEM-X255 Installation Instructions
X
L
NAPCO Security Systems
WI1093C 3/04
Compatible Smoke Detectors
4 Wire Smoke Detectors
Manufacturer Model Base
Gentex 812, 812T, 812P, N/A
812PT, 812PH, N/A
8120, 8120T, N/A
8120P, N/A
8120PTY, 8120-PH N/A
Hochiki SLG-12 w/YBC-RL4-RA base N/A
NAPCO FW-4 N/A
Sentrol/ESL 445AT, 445C, N/A
445CT, 445CR, N/A
445CRT N/A
System Sensor 1112, 2112, N/A
21112T, 211TSRB N/A
1412TH, 2412TH N/A
2312/24T, 1412, N/A
Subtract total smoke-detector alarm current
Note:
from available standby current.
UL Compatible Smoke Detectors (Providing UL Recognition or Listing)
2 Wire Smoke Detectors
Manufacturer Model Base
NAPCO FW-2 N/A
Sentrol/ESL 711U, 712U, 701U, 702U,
721U, 721UT, 702RE, 702RU
722U, 731U, 732U
System Sensor 1100, 1151, N/A
1400, 2100, N/A
2100T, 2100S, N/A
2100TS, 2151, N/A
2400, 2400TH N/A
Voltage Rating: 8.5–13.3 VDC
Note:
Maximum Number of Detectors: 10
Page 9
!
Note: Any normally-open devices that do not require power from the control panel may be used (such as
pull stations, waterflow and thermostats), if acceptable to the authority having jurisdiction.
SUMMARY OF UL REQUIREMENTS
Residential
Recognized Limited-Energy Cable for initiating, indicating and supplementary circuits.
!
Initiating loops supervised if longer than 3 feet
!
FT2200 End-of-Line Relay for Fire (if using 4-wire smoke detectors)
!
! Minimum alarm timeout of 5 minutes
! Maximum exit time: 60 seconds
! Maximum entry time: 45 seconds
Do not program “Swinger Shutdown”, “Auto Arming”, “Selective Bypass”, “Interior (Group) Bypass”, or “50 ms
!
or 20ms Loop Response”
“Abort Delay” may not exceed 45 seconds
!
Program “Disable Callback Download”
!
Automatic dialer may not dial a police station number that has not been dedicated for such service
!
System must be tested at least weekly under AC/battery and Battery-Only conditions
!
Replace the rechargeable battery at least every 5 years
!
If the battery is heavily discharged, replace it or have it tested by a qualified technician
!
! For silent panic, connect only to UL-listed holdup devices
! All zones must be programmed for “Priority”
! Do not program any zones for “Keyswitch Arming”
System must be serviced at least once every year
!
Residential Fire and Combination Residential Fire & Burglary must program “Residential Fire”
!
Keypad Expansion (EZM) Zones are not to be used as fire zones
!
L
NAPCO Security Systems
X
GEM-X255 Installation Instructions
Page 10
!
WI1093C 3/04
INSTALLATION
CAUTION: This equipment generates and uses radio-frequency energy. If not installed using conventional installation
practices for RF devices, it may cause interference to radio and television reception. It has been tested and found to
comply with the limits for a Class A computing device pursuant to Subpart B of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference. However, there is no guarantee that interference will
not occur in a particular installation. If it has been found to cause interference to radio or television reception, which can
be determined by removing and reapplying AC and battery power to the equipment, the installer should try to correct
the interference by one or more of the following measures: reorient the receiving antenna; connect the power transformer to a different outlet so that the control panel and receiver are on different branch circuits; relocate the control
panel with respect to the receiver.
MOUNTING
Control Panel
Choose a mounting location accessible to (a) a continuously-powered AC source, (b) system ground, a steel or copper
ground rod, ideally no further away than 10 feet, and (c) telephone lines (keep telephone wiring away from keypad
wires). Remove appropriate knockouts for cables. Place the control panel at a convenient viewing height and mark the
mounting holes. Attach the enclosure using screws suitable for the mounting surface.
Grounding
Connect the control-panel grounding screw through a No. 16 AWG. or larger wire to a long steel or copper ground rod
driven deeply into the earth. Do not use a gas pipe, plastic pipe or ac ground connections. Make the run as short and
direct as possible, without any sharp bends in the wire.
Tamper Switches
Tamper switches may be installed to prevent opening of the control-panel door or removal of the cabinet from the wall.
Ideally, tamper switches should be connected to a zone that is active at all times, thus it may be necessary to program
that zone as a 24-Hour Zone or Day Zone. When used on a normally-open zone, normally-closed tamper switches
(open when set) should be wired in parallel. On a normally-closed zone, install Napco TPS-2 normally-open tamper
switches (closed when set) in series.
INSTALLATION
There are two places in the cabinet to mount tamper switches: (1) To prevent cabinet removal from the wall, there are
three mounting holes on the left side of the cabinet, another hole on the back that allows the switch button to contact the
wall. (2) To prevent opening the cabinet door, there are three mounting holes on the right side of the cabinet. When
mounted, the switch button should contact the inside of the door. Be sure to alert the user that opening the enclosure
door will cause a tamper alarm.
one self-tapping screw. The sole purpose of the self-tapping screw is to tap the holes for the machine screws; it may be
discarded after use.
Note:
Keypad
A keypad should be located near each exit/entry door. The keypad features a handy pull-up reference label. Before
mounting the keypad onto the wall, push the Sliding Label Plate (with label and felt backing affixed and handle facing
forward) down the guides at the rear of the keypad until it snaps into place. Once installed, the Sliding Label Plate cannot be removed without first removing the keypad from the wall. Note: (1) The keypad fire and panic keys should not be
considered a substitute for a listed manual initiating device, such as a pull box. (2) Each GEM-RP1CAe2/GEM-K1CA
includes provisions for four additional zones. See ADDING EXPANSION ZONES.
If installing onto a double-gang box, insert mounting screws through the two vertical elongated holes on the left side of
the case and into the box. If the box is visible when viewed from the front, adjust the keypad vertically and tighten the
screws. Then, using hardware suitable for the mounting surface, add one or two screws at the right side of the keypad
case directly into the wall to ensure a secure installation.
cause the keypad case to distort.
Each tamper switch is furnished with three machine screws for mounting, and
Note:
Do not overtighten the screws! Uneven walls may
GEM-X255 Installation Instructions
X
L
NAPCO Security Systems
WI1093C 3/04
Page 11
!
Wiring
Wire keypad(s), zones, expansion zone modules and output devices as shown on the Wiring Diagram. Note that the
Wiring Diagram contains important information not available elsewhere in this manual.
CAUTION: Do not run telephone wiring near speaker wires; do not run keypad wiring with loop wiring.
Adding Expansion Zones
GEM-X255 Series control panels will handle up to 8 zones as is, however this number may be increased to as many as
255 programmable zones using optional expansion zone modules (EZMs).
Wireless Systems
With the addition of at least one GEM-RECV series receiver, the GEM-X255 will support up to 255 wireless transmitters.
The panel can accommodate one to four receivers within the premises, responding to the one with the stronger transmitter signal. If any transmitters are selected for the default program, a GEM-RECV receiver will automatically be programmed.
The keypad can display the status of any transmitter, indicating the condition of the zone (normal or open) and transmitter troubles (low battery, tamper or supervisory failure), and signal strength of the last transmission. A receiver failure
will be indicated by “E06-NN” (“no response”, with NN representing the receiver number).
(NOT EVALUATED BY U.L. FOR COMMERCIAL APPLICATIONS)
TYPICAL RESIDENTIAL FIRE INSTALLATION (Where permitted by local codes)
At least one smoke detector should be installed directly outside
each sleeping area. If there is more than one floor, additional
smoke detectors should be installed on each level, including the
basement. The living-area and basement smoke detectors
should be installed near the stairway of the next upper level.
For increased protection, additional detectors should be installed
in areas other than those required, such as the dining room, bedrooms, utility room, furnace room, and hallways. Heat detectors,
rather than smoke detectors, are recommended in kitchens, at-
tics, and garages due to conditions that may result in false
alarms and improper operation. Large areas and areas with partitions, ceiling beams, doorways, and open joists will require additional detectors.
Refer to NFPA Standard No. 74 (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269) for additional information, including proper mounting of detectors.
heard by all partitions. Note: NFPA 74 (Household Fire Warning Equipment) requires that a fire alarm audible device be
installed indoors. The User Program Code is not to be given to anyone except the authority responsible for all partitions.
TYPICAL PARTITIONED INSTALLATION
Described and illustrated here are an example of a partitioned system
with common-area protection of the control-panel room. This system
meets UL requirements for a partitioned installation.
•Both areas must be owned and managed by the same person(s).
•Both areas must be part of one building at one street address.
The control panel and all wiring protecting each partitioned area
•
must be confined to the respective area and may not encroach upon the
other area. This requires that the control panel room have redundant
protection; that is (a) multiple sets of door contacts, each wired to a
separate zone and (b) one of those zones programmed for each area.
In order to gain access to this protected area without causing an alarm,
both partitions must be disarmed. In lieu of redundant protection, 24Hour Zones may be used. Any zone protecting the control panel and
transformer may not be programmed for bypass.
The sounding device must be placed such that the bell test can be
INSTALLATION
L
NAPCO Security Systems
X
GEM-X255 Installation Instructions
Page 12
!
WI1093C 3/04
UL COMMERCIAL-BURGLARY INSTALLATIONS
The GEM-X255M can be used as part of a UL Central
Station Grade C, B, or A installation. Normally, a digital
communicator is classified as Grade C and may be classified Grade B if used with the specified Grade-A Local bell
and bell housing. A UL Central Station Grade-A installation requires the use of a Napco RM3008 Relay Board
and Ademco 7720 Radio System. Refer to the installation
instructions furnished with each component for respective
installation requirements.
For a UL Commercial Grade-A Police Station Connection,
refer to GRADE-A LOCAL MERCANTILE INSTALLATIONS, which follows. Use the M278 Line-Reversal
Monitor to provide basic line security; refer to the instructions accompanying the M278 for other installation requirements. For UL Commercial safe and vault applications, use a UL-listed shock sensor suitable for metal enclosures. Install tamper switches on front and rear of control-panel enclosure.
Grade-A Local Mercantile Installations
A Grade-A Local Mercantile installation must use at least
a 6.0AH standby battery. Programming must include
Auto Bell Test on Arming. Trouble on Night Open may
not be programmed for any zone. The minimum requirements for a listed Grade-A Local system include:
Low-Battery Annunciation.
•
An Ademco AB-12 Bell and Box (12-volt).
•
•Program Auto Bell Test on Arming.
•A maximum Entrance and Exit Delay of 60 seconds.
Interfacing to the Ademco 7720 Long-Range Wireless System
INSTALLATION
The RM3008 may be used to interface the GEM-X255M control panel to the Ademco 7720 transmitter in order to meet
UL Central Station Grade-A or Grade-B requirements by using a digital communicator combined with one-way wireless.
(Normally, a digital communicator is Grade C, and may be Grade B if the specified Grade-A local bell is used.) Refer to
the wiring diagram which follows, and to the instructions furnished with the Napco and Ademco equipment for further information concerning the DACT, listed compatible receiver and formats, Grade-A local bell and bell housing. Enable
Line Fault Test must be programmed.
Central Station Grade-B Requirements
Wiring to the Ademco 7720 transmitter must be enclosed in rigid conduit when outside walls, or in flexible conduit when
inside walls or above ceilings, for the entire length up to the transmitter room. The transmitter room must be protected
by a UL listed intrusion detection unit that is connected to one of the input channels of the Ademco 7720. Relays must
be programmed to trip the Ademco 7720 for alarms on all protective circuits, including tampers, telco phone failure, 24hour test timer, transmitter low battery and ac loss. (See PCD3000 External Relay Control screen). One zone on the
GEM-X255M, programmed as a 24-Hour Zone, must supervise the radio.
Central Station Grade-A Requirements
In addition to Grade-B Requirements (above), one relay on the RM3008 must be programmed to trip the Ademco 7720
when the telephone line fails. Daily openings and closings are required to be transmitted by the Napco panel along with
the 24-hour DACT test signal and DACT trouble conditions.
GEM-X255 Installation Instructions
X
L
NAPCO Security Systems
WI1093C 3/04
Page 13
TESTING THE SYSTEM
After installation is completed, test the system as follows.
!
1. Call the central station to inform them of the test.
!
2. Initiate an alarm, preferably on a zone that activates a steady siren, and verify proper signaling.
!
3. Wait 5 minutes.
!
4. Call the central station to confirm their receipt of a good transmission.
Note: Be sure to test all enabled keypad panics.
Signal Strength Testing/Wireless Systems
To test the operation of wireless transmitters, proceed as follows. (Note: Wireless systems have not been investigated
by UL).
!
Fault a point of each transmitter to be tested by faulting the zone.
The transmitter signal strength can be displayed using the DISPLAY RF XMITTER STAT function. Enter a Level 3 User
Code or enter the Dealer Code, press the
played. Press YES (
less Signal Strength will be displayed from 1 to 10 with 10 being the strongest signal and any signal under 3 as unac-
ceptable. Except in the Fault-Find Mode, signal strengths less than 3 will be entered into the system log. Press NEXT
E button) to step the next zone.
(
The last received signal strength for each transmission is always stored in memory and can viewed at any time using
this procedure. Signal strength can also be viewed through the PCD-Windows Status Screen.
E button) and the Wireless Signal Strength of the wireless zone will be displayed. The Wire-
A
button and answer NO until “
DISPLAY RF XMITTER STAT
” is dis-
!
INSTALLATION
L
NAPCO Security Systems
X
GEM-X255 Installation Instructions
Page 14
!
WIRING CONNECTIONS
BATTERY
(+)
4 AH, 6 AH OR 7 AH
RECHARGEABLE
BATTERY 12 VDC
(–)
TRANSFORMER
AC IN, 16.5V/60HZ VIA
TRF11 OR TRF14
CLASS 2 TRANSFORMER
DO NOT CONNECT TO
SWITCHED OUTLET
RED
BLACK
1
2
Connect a 16.5 VAC Transformer to Terminals 1 and 2, using a wire of #18 AWG. or
less at a distance of 15 ft. or less from the control panel. NOTE: Do not connect to a
switched outlet.
WI1093C 3/04
The RED (+) and BLACK (-) flying leads must be connected to
E1
a 12VDC 4, 6 or 7 AH Rechargeable Battery, to serve as
backup power in the event of AC Power Failure. NOTE: To
E2
calculate the available standby time refer to the StandbyBattery Calculation Worksheet at the back of this manual.
SIREN/BELL BURG/FIRE ALARM OUTPUT
Connect the alarm sounding devices (self-contained sirens, speakers or a mechanical bells) to
terminals 5 (+) and 14 (-). Any self-contained siren requiring a 12 VDC input can be connected.
When connecting a mechanical bell, it must be supervised using a 2.2k Ohm resistor. To connect 8 Ohm Speakers use a Siren Driver with the proper polarity observed. NOTE: Refer to the
Wiring Diagram for alarm current specification, bell supervision and burglary output relay.
Note: In NFPA Household Fire Installations. only a single siren or bell can be used on this bell
circuit.
WIRING CONNECTIONS
AUXILIARY ALARM OUTPUT
12VDC
Auxiliary Output can be activated depending on the programming options selected (see GEMX255 Programming Instructions). Connect the device controlled by the programmable output
between terminal 8 (+) and terminal 14 (-). A programming option “AuxOut Chirp on Key-fob
Arm/Disarm” is available. If selected, an external siren driver can be connected to these terminals.
GEM-X255 Installation Instructions
X
L
NAPCO Security Systems
WI1093C 3/04
REMOTE BUS
Page 15
!
GEM-RECV-8
GEM-RECV-16
GEM-RECV-96
GEM-RECV-255
NOTE: Refer to the EZM Installation Instructions for
specific wiring information.
Door
Strike
BLK
RED
External
RB1000 Relay
BLK
RED
(recommended)
13
(N/O)
(COM)
(+)
Power
(–)
Supply
WIRING CONNECTIONS
1.
KEYPADS:
2.
X-10 INTERFACE:
3.
WIRED ZONE EXPANDER:
4.
WIRELESS RECEIVERS:
GEM-RECV255
5.
RELAY MODULE:
6.
VOICE INTERFACE:
7.
TELEPHONE INTERFACE:
GEMINI
STATUS
ARMED
A
1243
B
C
7890
COMPUTERIZED SECURITY SYSTEM
GEM-RP1CAe2
(2 LINE LCD KEYPAD)
(EZM/PGM Options 1 or 2)
GEM-RP1CAe2, GEM-K1CA
SYSTEM ARMED
01/01/97 12:00AM
D
56
E
F
G
NEXT/YES
PRIOR/NO
GEM-X10
RM3008
AREA
AVAILABLE DEVICES
GEM-EZM4 & GEM-EZM8
GEM-RECV8, GEM-RECV16, GEM-RECV96 &
GEM-EVA 1
WIZARD IIe
R
BROWN
Keypad Brown Wire: EZM/PGM Output Options
Select either option with GEM-RP1CAe2/GEM-K1CA keypads.
Option 1. Activates the PGM lug on the corresponding EZM module(s). Lug goes active (low) when
any selected Area is armed.
Option 2. The Access Code will activate the keypad's PGM brown wire while armed or disarmed if
the User Code is programmed for "Access Control on PGM Lug". The Access Code is programmed as any other User Code but without arm/disarm capability. Note: Options not investi-
gated by UL.
Connect the available devices as shown above to the remote bus terminals (9, 10, 11 & 12). Observe the correct color
wire connections. When connecting a keypads, first configure them accordingly (refer to the Keypad Configuration
Mode at the back of this manual). Keypads should be located near every exit/entry door. Up to 15 keypads may be
connected if the longest cable run from the panel, to the farthest keypad (daisy chained or home-run) is less than 1000
feet. The maximum distance for seven keypads is 300 feet using 22 AWG. wire. NOTE: When running keypad wire,
avoid wiring parallel to other types of wiring that can cause electrical interference.
EARTH GROUND
Connect the control panel EARTH GROUND screw through a No. 16 AWG.
or larger wire to a metal cold-water pipe. Do not use a gas pipe, plastic pipe
or AC ground connections. Also, connect the circuit board to the metal enclo-
NOTE: Do not use a gas pipe, plastic
pipe or AC ground connections.
sure. Connect a wire with a ground lug crimped or soldered onto one end of
the EARTH GROUND screw to the cabinet.
NOTE:
Grounding connections
should avoid bends in the grounding wire whenever possible.
AUXILIARY POWER
(+)
AUX POWER
(-)
Connect the auxiliary devices (motion detectors, glass breaks, etc.) to Terminals 13 and 14.
13
Auxiliary Power provides a filtered 12 VDC nominal output which is used for powering auxiliary
devices.
14
Worksheet at the back of this manual.
NOTE:
To calculate the available standby time refer to the Standby-Battery Calculation
L
NAPCO Security Systems
X
GEM-X255 Installation Instructions
Page 16
!
RESET OUTPUT
WI1093C 3/04
15
RESET
OUTPUT
Reset Output can be activated depending on the programming options selected (see GEMX255 Programming Instructions). Connect the device controlled by the programmable output
between terminal 15 (+) and terminal 14 (-).
BASIC ZONE CONFIGURATION
The basic zone configuration for the GEM-X255 is 8 zones. Connect as shown above to terminals 16-27. Normally
Closed (N.C.) devices may be wired in series or Normally Open (N.O.) devices may be wired in parallel. Use the 2.2K
Ohm end-of-line (E.O.L.) resistor in each zone, if selected in programming (refer to the GEM-X255 Programming Instructions WI1092). Zones 1-8 can be selected for a “Fast Loop Response (20 ms or 50 ms)” or a “Normal Loop Response
(750 ms)”. Other zone options include Entry/Exit, Interior, 24 Hour Protection, Trouble, Fire, Instant, Chime, Area Selection and Relay Output selection.
EXPANDED ZONE CONFIGURATION
WIRING CONNECTIONS
GEM-RECV-8
GEM-RECV-16
GEM-RECV-96
GEM-RECV-255
The GEM-X255 Control Panel may be expanded up to 255 zones. This may be accomplished by adding 88 zones to the
basic 8 zone configuration. Hardwired zone expanders include: GEM-EZM4 (4 additional zones per module), GEMEZM8 (8 additional zones per module) and GEM-RP1CAe2/GEM-K1CA Keypad (4 additional zones per keypad). Wireless zone expanders include: GEM-RECV8 (8 additional zones per receiver), GEM-RECV16 (16 additional zones per receiver), GEM-RECV96 (96 additional zones per receiver) and GEM-RECV255 (247 additional zones per receiver). Wireless transmitters include: GEM-TRANS2, GEM-KEYF, GEM-SMK, GEM-PIR, GEM-DT and GEM-GB.
Additional Zones are numbered 9-96.
GEMINI
SYSTEM ARMED
01/01/97 12:00AM
STATUS
ARMED
1243
A
56
B
7890
C
COMPUTERIZED SECURITY SYSTEM
GEM-RP1CAe2
(2 LINE LCD KEYPAD)
NEXT/YES
E
PRIOR/NO
D
F
AREA
G
R
GEM-X255 Installation Instructions
X
L
NAPCO Security Systems
WI1093C 3/04
4-WIRE SMOKE DETECTORS
4-WIRE SMOKE DETECTOR WIRING
29
28
6
(-)
The GEM-X255 can use conventional 12 VDC 4-wire smoke detectors. To use them,
the select fire zone programming option and do not select 2-wire smoke detector programming option for the desired fire zone (refer to the GEM-X255 Programming Instructions WI1092). Set JP7 to the BURG position as shown, if zones 7 or 8 are to be
used.
Four wire smoke detectors may be connected to any programmed fire zone (1-8) as
shown, within the panel. If external EZMs are used for zones 9-255, then 4-wire smoke
detectors may be connected to any programmed fire zones (9-255). (Do not use in UL
installations. See page 9).
Power must be obtained from terminal 28 (+) and 29 (-). If Fire Alarm Verification is desired to reset the smoke detectors, select this option for the desired fire zone. (Do not
use in UL installations. See page 9).
NOTE: Do not program Fire Alarm Verification in California.
Page 17
!
WIRING CONNECTIONS
2-WIRE SMOKE DETECTORS
2-WIRE SMOKE
DETECTOR WIRING
Two-wire smoke detectors may be connected to control panel zones 1-8. Zones
7 and 8 may be configured for 2 wire fire through the JP7 jumper settings. To
enable, program the zone(s) as Fire Zones, enable 2-Wire Fire (refer to the
GEM-X255 Programming Instructions WI1092) and set JP7 to the position as
shown. Connect the 2-wire smoke detectors as shown.
Zones 1-6 may be configured for 2-wire Fire with the use of an EOL130 resistor
and the cut of a control panel resistor, as displayed on the next page.
26 27 28
If Fire Alarm Verification is desired to reset the smoke detectors, select this option for the desired fire zone (zone 7 or 8).
NOTE:
Do not program Fire Alarm Verification in California
(BASIC CONFIGURATION)
L
NAPCO Security Systems
X
GEM-X255 Installation Instructions
Page 18
!
WI1093C 3/04
2-WIRE SMOKE DETECTORS
(EXPANDED CONFIGURATION)
Where more than two 2-wire smoke detector zones
are required, select any of Zones 1–6 for 2-wire fire
as follows:
1. Program the selected zone(s) (1–6) for 2-Wire
Smoke Detectors and Fire.
2. Cut the lead of the 2700W resistor (color code:
red/violet/red) associated with the selected zone
(s). See following table.
ZONE RESISTOR LOCATION ON BOARD
1 R1 ABOVE TERMINAL 18
2 R2 ABOVE TERMINAL 18/19
3 R3 ABOVE TERMINAL 19
4 R4 ABOVE TERMINAL 20
5 R5 ABOVE TERMINAL 22
6 R6 ABOVE TERMINAL 23
3. Install a 130W resistor (Napco Part No. EOL130;
color code: brown/orange/ brown), 3 watts,
across the two terminals of each selected zone.
4. Wire the positive (+) terminal of the smoke detector to Terminal 28. Wire the negative (–) terminal of the smoke detector to the positive terminal (+) of the zone.
Connecting 2-wire smoke detectors to zones 1-6
TELEPHONE LINES
30 31 32 33
WIRING CONNECTIONS
Model 368 Cord
GRAY
BRN
Connect the Model 368 Cord as follows: 30 (RED = Telco Tip), 31 (GREEN = Telco Ring), 32 (GRAY = Home Tip)
and 33 (BROWN = Home Ring). Insert the modular plug into an approved USOCRJ31X jack (or a CA31A jack for
Canadian installations). The Telco Line is used by the control panel to dial the central station and for downloading.
This line should not be connected to party lines or coin operated telephones. If connected to a line with call waiting,
then call waiting interrupt numbers must be programmed into the CS Telephone Numbers (refer to the GEM-X255
Programming Instructions WI1092).
GEM-X255 Installation Instructions
X
L
NAPCO Security Systems
WI1093C 3/04
KEYPAD CONFIGURATION MODE
This section will focus on configuring the GEM-RP1CAe2/GEM-K1CA Keypads. If there is more than one keypad in the system, only
Keypad No. 1 may be used for programming.
Page 19
STATUS
ARMED
KEYPAD INSTALLATION
Each keypad must be assigned an address number (1–15) and each requires its own configuration procedure (see CONFIGURING
THE KEYPADS, which follows, and DIRECT ADDRESS KEYPAD AREA OPTIONS). At least 1 keypad must be used; only 1 is required for a single-area Commercial Burglary installation.
GEM-RP1CAe2/GEM-K1CA - is a 2-line combination fire/burglary/access keypad capable of supporting 4 EZM zones. A GEM-
•
RP1CAe2 or GEM-K1CA is recommended for use as Keypad #1.
•
CONFIGURING THE KEYPADS
A total of up to 15 keypads may be connected to the panel. GEM-RP1CAe2/GEM-K1CA keypads may be intermixed but require different configuration procedures, as described in the following paragraphs. If you have a GEM-K1CA keypad, please see the "Important
Note" on page 3 regarding the differences between the GEM-RP1CAe2 and the GEM-K1CA keypad buttons. The buttons displayed below will be for the GEM-K1CA keypad.
Configuring the GEM-RP1CAe2/GEM-K1CA Keypad
Each GEM-RP1CAe2/GEM-K1CA keypad must be configured for (a) keypad tactile beep; (b) entry sounder;
(c) keypad address; (d) EZM address; and (e) zone response.
To enter the GEM-RP1CAe2/GEM-K1CA Configuration Mode:
1. Move jumper JP1 (located at the upper center of the control panel board) from Pins 1-2 (top two) to
Pins 2-3 (bottom two).
2. After about 15 seconds, the display will read “
3. Press 11123R and proceed as follows. (Repeat the following procedure for all keypads.)
See the Wiring Diagram.
NOTE:
XX OUT OF SYSTEM
”, where XX indicates the keypad address.
Keypad Tactile Beep
Keypad Beep
ON
Upon entering the Keypad Configuration Mode, “
indicating that the tactile beep, which sounds when any button is pressed, is on. To
turn off the tactile beep, press the
beep on and off). Press the
to exit.
R button to continue or press the C button
button (the U button will toggle the tactile
U
KEYPAD BEEP ON
Entry Sounder
Entry Sounder
ON
To turn off the keypad sounder during entry time, press the U button (the U button
will toggle the entry sounder on and off). Press the
press the
C button to exit.
R button to continue or
Keypad Address
If more than one keypad is installed, each must be assigned a unique keypad ad-
Keypad Address
01
To assign the keypad number, proceed as follows:
1. Enter the assigned keypad number 01–15, then press the U button to save. A valid number will be acknowledged by a short
beep; an invalid number will be rejected by a long beep.
2. Press the
R button to continue or press the C button to exit.
dress (that is, no two keypads may be numbered alike):
keypads must be numbered consecutively (missing numbers are not permitted)
!
!
only Keypad No. 1 may be used for programming.
NORMAL
KEYPAD
CONFIGURE
” will be displayed,
!
KEYPAD CONFIGURATION MODE
L
NAPCO Security Systems
X
GEM-X255 Installation Instructions
Page 20
!
NEW COMPAT#
0000
keypad may not be removed for use on a system with a different compatibility number. Note: If assigning compatibility
numbers, record and store them in a safe place.
While the compatibility number may be changed, the old number must be known in order to program the new number.
Note: If neither the control panel nor the keypad is given a compatibility number, both default to “0000” (thereby maintaining compatibility).
To program the compatibility number, press the
compatibility number that is programmed into the panel.
compatibility number other than “0000”, the display would read “OLD COMPAT# XXXX”. Enter the existing number before at-
tempting to change it. Press the
EZM ADDRESS
A button to continue or press the C button to exit.
01
Workbook) similar to its keypad address. If no other EZMs are to be used, designate the keypad as Group “01” at the
EZM ADDRESS 00
“
must have a unique assigned group number, starting with “01” and proceeding consecutively). Press the
to continue or press the
ZONE RESPONSE
” display. In multiple-EZM systems, enter an assigned group number “01” through “22”. (Each EZM
button to exit.
C
00
2. Add up the circled numbers.
3. At the keypad, enter the sum as a two-digit number “01” through “15” on the display, then press the
Example. Change Zones 2, 3 and 4 to 50mS response.
KEYPAD CONFIGURATION MODE
1. Circle numbers for Zones 2, 3 and 4: (2), (4) and (8).
2. Add up the circled numbers: 2 + 4 + 8 = 14.
3. Enter “14” at the keypad, then press the
Press the
A
button to continue or press the
Compatibility Number
The compatibility number is a 4-digit security code that, if programmed into
both the control panel and each GEM-RP1CAe2/GEM-K1CA keypad, dedicates the keypad to only that panel. That is, (a) similar keypads not having
the correct compatibility number will not operate in the system and (b) a
A
button until “
Note:
NEW COMPAT# 0000
If the keypad had been previously programmed for a
” is displayed. Enter the 4-digit
EZM Address
The keypad's internal EZM (Expansion Zone Module) may be utilized to
provide four additional wired zones. Whether used alone or in conjunction
with optional GEM-EZM series modules or other keypad EZMs, it must be
assigned a unique address (or Group number, see Keypad Programming
Zone Response
The normal loop response of each keypad expansion zone is 750mS, however the response time of any zone can be reduced to 50mS as follows.
1. Of the following, circle the number(s) in parentheses associated with the
zone(s) to be changed: Zone 1=(1); Zone 2=(2); Zone 3=(4); Zone 4=(8)
button.
J
C
button to exit.
WI1093C 3/04
A button
button.
J
Program Control Message
PROG CONTROL
MESSAGE# 1
for changes) or press the
(display will read “
(top two).
01 OUT OF SYSTEM
C button to exit the Keypad Configuration Mode
”). Then replace Jumper JP5 across Pins 1–2
The Access-Control message normally displays “**ENTER NOW**” however
this display may be changed to any of the following messages as displayed
in the table at right:
A
Press the
display will loop back through selections,
button to continue (the
Program Control Message
0 (No Message)
1 **Enter Now**
2 Door Control
3 Gate Control
4 Light Control
5 Control #1
6 Control #2
GEM-X255 Installation Instructions
X
L
NAPCO Security Systems
WI1093C 3/04
THIS PAGE INTENTIONALLY LEFT BLANK
Page 21
!
KEYPAD CONFIGURATION MODE
L
For direct line to Technical Service, call toll free: (800) 645-9440
NAPCO Security Systems
NAPCO Security Systems, Inc.
333 Bayview Avenue, Amityville, New York 11701
For Sales and Repairs, call toll free: (800) 645-9445
Internet: http://www.napcosecurity.com
X
GEM-X255 Installation Instructions
Loading...
+ 47 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.