85
JW RELAYS
VDE
COMPACT PC BOARD
POWER RELAY
20.0
.787
12.8
.504
28.6
.1.126
mm inch
FEATURES
• Miniature package with universal terminal footprint
• High dielectric withstanding for transient protection:
10,000 V surge in µs between coil and contact
• Sealed construction
• Class B coil insulation types available
• TV rated (TV-5) types available (only for 1 Form A type)
• VDE, TÜV, SEMKO, SEV, FIMKO, TV-5 also approved
SPECIFICATIONS
Contact
Coil
Characteristics
Standard type High capacity type
Arrangement
1 Form A, 1 Form C,
2 Form A, 2 Form C
1 Form A, 1 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
100 m
Ω
Contact material Silver alloy
Rating
(resistive
load)
Nominal switching capacity
5 A 250 V AC,
5 A 30 V DC
10 A 250 V AC,
10 A 30 V DC
Max. switching
power
1,250 VA, 150 W 2,500 VA, 300 W
Max. switching
voltage
250 V AC, 30 V DC
Max. switching
current
5 A 10 A
Expected
life (min.
ope.)
Mechanical
(at 180 cpm)
5×10
6
Electrical (at 6 cpm)
(Resistive load)
10
5
Nominal operating power 530 mW
Standard type High capacity type
Max. operating speed (at
rated load)
6 cpm
Initial insulation resistance Min. 1,000 MΩ at 500 V DC
Initial
breakdown
voltage*
1
Between open contacts
1,000 Vrms for 1 min.
Between contacts and coil
5,000 Vrms for 1 min.
Between contact sets
3,000 Vrms for 1 min. (2 Form A, 2 Form C)
Initial surge voltage between
contacts and coil*
2
Min. 10,000 V
Operate time*
3
(at nominal voltage)
Max. 15 ms
Release time (without diode)*
3
(at nominal voltage)
Max. 5 ms
Temperature rise (at 20°C)
(at nominal voltage)
(with nominal coil voltage and at
nominal switching capacity)
1a: max. 39°C
1c, 2a, 2c: max. 55°C
(resistance method)
1a: max. 45°C
1c: max. 55°C
(resistance method)
Shock
resistance
Functional*
4
Min. 98 m/s2 {10 G}
Destructive*
5
Min. 980 m/s2 {100 G}
Vibration
resistance
Functional*
6
Approx. 98 m/s2 {10 G}, 10 to 55 Hz at
double amplitude of 1.6 mm
Destructive
Approx. 117.6 m/s2 {12 G}, 10 to 55 Hz
at double amplitude of 2.0 mm
Conditions for operation,
transport and storage*
7
(Not freezing and condensing at low temperature)
Ambient
temp.*
8
–40°C to +85°C –40°F to +185°F
Humidity 5 to 85% R.H.
Unit weight Approx. 13 g .46 oz
Remarks
* Specifications will vary with foreign standards certification ratings.
*1Detection current: 10mA
*
2
Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981
*3Excluding contact bounce time
*
4
Half-wave pulse of sine wave: 11ms; detection time: 10µs
*5 Half-wave pulse of sine wave: 6ms
*6Detection time: 10µs
*
7
Refer to 5. Conditions for operation, transpor t and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
*
8
When using relays in a high ambient temperature, consider the pick-up voltage
rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 33.8°F
with 20°C 68°F as a reference) and use a coil impressed voltage that is within the
maximum allowable voltage range.
TYPICAL APPLICATIONS
1. Home appliances
TV sets, VCR, Microwave ovens
2. Office machines
Photocopiers, V ending machines
3. Industrial equipment
NC machines, Robots, Temperature
controllers