JV-N
315
JV-N
RELAYS
COMPACT FLAT POWER
RELAY FOR HEATER LO ADS
22
.866
16
.630
10.9
.429
FEATURES
• High 16 A capacity
The contacts are high capacity 16A, 125 V A C .
• Compact, flat type with low 10.9 mm
.429 inch height
Compact flat type with low surface area of
16 × 22 mm .630 × .866 inch and height of
10.9 mm .429 inch.
• High sensitivity at 200 mW
High sensitivity at 200 mW coil power consumption.
• Represses contact terminal heat
The contact terminals are larger and
thicker compared to the existing JV relay.
This limits the rise in temperature of the
terminals when there is a large current
flowing to approx. 28 ° C 62°F (normal current of 16 A).
• Conforms to the various safety standards
UL/CSA, TÜV approved.
SPECIFICATIONS
Contact
Coil
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Excluding contact bounce time
*
2
Excluding contact bounce time, without diode
*
3
By resistive method; nominal v oltage applied to the coil; contact carrying current:
16A, at 70 ° C 158 ° F
*
4
Nominal voltage applied to the coil, at 60 ° C 140 ° F
*
5
Half-wave pulse of sine wave: 11 ms; detection time: 10 µ s
*
6
Half-wave pulse of sine wave: 6 ms
*
7
Detection time: 10 µ s
*
8
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
Characteristics
Arrangement 1 Form A
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Max. 30 m Ω
Contact material Silver alloy
Rating
(resistive
load)
Nominal switching
capacity
16 A 125 V AC , 10 A 277 V A C
10 A 30 V DC, 10 A 125 V AC
Max. switching power 2,770 VA, 300 W
Max. switching voltage 277 V AC, 30 V DC
Max. switching current 16 A (AC 125 V), 10 A (DC)
Expected life (min. ope.)
Mechanical (at 180 cpm)
2 × 10
7
Electrical at
resistive
load (at 20
cpm)
Sealed type
16 A 125 V AC, 10 A 30
V DC
10
5
Flux-resistant type
10 A 125 V AC
3 × 10
5
Nominal operating power
200 mW (DC 4.5 to 48 V)
600 mW (DC 100 V)
Max. operating speed 20 cpm
Operate time*
1
(at nominal voltage)
Max. 12 ms (DC 4.5 V to 48 V)
Max. 8 ms (DC 100 V)
Release time*
2
(at nominal voltage) Max. 5 ms
Initial insulation resistance Min. 1,000 M Ω (at 500 V DC)
Initial breakdown
voltage
(Detection
current: 10 mA
Between open
contacts
1,000 Vrms for 1 min.
Between contacts
and coil
2,500 Vrms for 1 min.
Surge voltage between contact and
coil
Min. 4,500 V
Temperature rise
Max. 45 ° C (DC 4.5 V to 48 V) *
3
Max. 55 ° C (DC 100 V)*
4
Conditions in case of operation,
transport and storage*
8
Ambient temperature
–40 to 70 ° C –40 to 158 ° F
(DC 4.5 to 48 V)
–40 to 60 ° C –40 to 140 ° F
(DC 100V)
Humidity: 5 to 85 % R.H.
(Note freezing and condensing
at low temperature)
Air pressure: 86 to 106 kPa
Shock resistance
Functional Min. 200 m/s
2
{20G}*
5
Destructive Min. 1,000 m/s
2
{100G}*
6
Vibration
resistance
Functional
10 to 55 Hz *
7
at double amplitude of 1.6 mm
Destructive
10 to 55 Hz at double
amplitude of 2 mm
Unit weight Approx. 8g .28 oz
TYPICAL
APPLICATIONS
• AV equipment: TV's, VTR's, etc.
• OA equipment
• HA equipment
ORDERING INFORMATIONS
Contact arrangement Protective construction
UL/CSA, TÜV approved type is standard.
Coil voltage (DC)
4.5, 6, 9, 12,
18, 24, 48, 100 V
1a: 1 Form A Nil:F:Sealed type
Flux-resistant type
Ex. JVN
1a
4.5 VF
–