NAIS JV1F-18V, JV1F-12V, JV1F-100V, JV1aS-6V, JV1aS-5V Datasheet

...
3 ×
5 ×
FLAT TYPE POWER RELAY
22
.866
16
.630
10.9
.429
mm inch
FEATURES
• Flat type: 16 mm (length) × 22 mm (width) × 10.9 mm (height)
(.630 × .866 × .429 inch)
• High capacity type (16A) available
• High sensitivity type (100 mW: 1 Form A) available
• TÜV also approved
SPECIFICATIONS
Contact
Standard type
High capacity
type Arrangement 1 Form A 1 Form C 1 Form A 1 Form A Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
50 m Ω
Contact material Silver alloy
5
5
10 A 125 V AC (N.O.)
6 A 125 V AC (N.C.)
1,250 VA (N.O.)
750 VA (N.C.)
10 A (N.O.)
6 A (N.C.)
5
10
5
10
16 A 125 V AC 10 A 125 V AC
2,000 VA 1,250 V
16 A 10 A
7
10
4
10
5
10
400 mW (up to 48 V coil type) 600 mW (100 V coil type)
Nominal switching capacity
Rating (resistive)
Max. switching power 1,250 VA Max. switching voltage 125 V AC Max. switching current 10 A
Expected life (min. ope.) Mechanical at (180 cpm)
Electrical at resistive (at 20 cpm) (at rated load)
Sealed type 10 Flux-resistant
type
Coil
Nominal operating power
Standard type High capacity type
High sensitivity type 100 mW
10 A 125 V AC
3 × 10
1 Form A type 1 Form C type
200 mW (up to 48 V coil type) 600 mW (100 V coil type)
Remarks
* Specifications will vary with foreign standards certification ratings.
1
*
Measurement at same location as "Initial breakdown voltage"section
2
*
Detection current: 10mA
3
Excluding contact bounce time
*
4
*
Half-wave pulse of sine wave: 11ms, detection time: 10 µ s
5
Half-wave pulse of sine wave: 6ms
*
6
*
Detection time: 10 µ s
7
Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24).
*
8
*
100V type: –40 to + 60 ° C –40 to + 140 ° F
High
sensitivity type
10
5
10
JV-RELAYS
Characteristics
Max. operating speed 20 cpm Initial insulation resis-
1
tance* Initial
break­down voltage*
Operate time* (at nominal voltage)
Release time (without diode)*
(at nominal voltage)
Temperature rise
4
(at 50°C)
Shock resistance
Vibration resistance
Conditions for opera­tion, transport and storage* (Not freezing and condensing at low temperature)
Unit weight Approx. 8 g .282 oz
Between open contacts
Between con-
2
tacts and coil
Functional* Destructive*
Functional*
Destructive
7
3
(100 V DC coil type)
3
Max. 65 ° C with nominal
coil voltage across
coil and at nominal
switching capacity
4
Min. 98 m/s
5
6
at double amplitude
at double amplitude
Ambient temp.
–40 ° C to +70 ° C*
–40 ° F to +158 ° F
Humidity 5 to 85%R.H.
Min. 100 M Ω
(at 500 V DC)
1,000 Vrms
for 1 min.
1,500 Vrms
for 1 min.
Approx. 10 ms
Approx. 5 ms
Approx. 4 ms
2
{10 G}
Min. 980 m/s
{100 G}
10 to 55 Hz
of 1.0 mm
10 to 55 Hz
of 1.6 mm
2
8
TYPICAL APPLICATIONS
1. Home appliances: Air conditioner, heater, etc.
2. Automotive: Power supply for car stereo and air conditioner
ORDERING INFORMATION
Ex. JV 1a P F S 12V
Contact arrangement
1: 1 Form C 1a: 1 Form A
1. Standard packing: Carton: 50 pcs.; Case: 1,000 pcs.
2. Coil voltage DC 48, 100 V types are not available for high sensitivity type.
UL/CSA, TÜV approved type is standard.
Rating Protective construction Sensitivity Coil voltage (DC)
Nil: Standard type P: High capacity type*
Nil: Sealed type F: Flux-resistant type
Nil: Standard type (1 Form A: 200 mW, 1Form C: 400 mW 100 V DC coil type: 600 mW) S: High sensitivity type* (1 Form A: 100 mW)
5, 6, 9, 12, 18,
24, 48, 100V
* Only for 1 Form A typeNotes:
87
JV
TYPES
Contact arrangement Coil voltage, V DC
5 JV1a-5V JV1aF-5V 6 JV1a-6V JV1aF-6V 9 JV1a-9V JV1aF-9V
1 Form A
Standard type
1 Form A
High capacity type
1 Form A
High sensitivity type
1 Form C
12 JV1a-12V JV1aF-12V 18 JV1a-18V JV1aF-18V 24 JV1a-24V JV1aF-24V 48 JV1a-48V JV1aF-48V 100 JV1a-100V JV1aF-100V 5 JV1aP-5V JV1aPF-5V 6 JV1aP-6V JV1aPF-6V 9 JV1aP-9V JV1aPF-9V 12 JV1aP-12V JV1aPF-12V 18 JV1aP-18V JV1aPF-18V 24 JV1aP-24V JV1aPF-24V 48 JV1aP-48V JV1aPF-48V 100 JV1aP-100V JV1aPF-100V 5 JV1aS-5V JV1aFS-5V 6 JV1aS-6V JV1aFS-6V 9 JV1aS-9V JV1aFS-9V 12 JV1aS-12V JV1aFS-12V 18 JV1aS-18V JV1aFS-18V 24 JV1aS-24V JV1aFS-24V 5 JV1-5V JV1F-5V 6 JV1-6V JV1F-6V 9 JV1-9V JV1F-9V 12 JV1-12V JV1F-12V 18 JV1-18V JV1F-18V 24 JV1-24V JV1F-24V 48 JV1-48V JV1F-48V 100 JV1-100V JV1F-100V
Ω ( ±
Part No.
Sealed type Flux-resistant type
COIL DATA (at 20 ° C 68 ° F)
Part No.
1 Form A
(Standard type &
High capacity
type)
1 Form A
(High sensitivity
type)
1 Form C
Nominal voltage,
V DC
5 4.0 0.25 125 40 200 7.5 6 4.8 0.3 180 33.3 200 9 9 7.2 0.45 405 22.2 200 13.5 12 9.6 0.6 720 16.7 200 18 18 14.4 0.9 1,620 11.1 200 27 24 19.2 1.2 2,880 8.3 200 36 48 38.4 2.4 11,520 4.2 200 72 100 48 3 16,600 6 600 110 5 4.0 0.25 250 20 100 9 6 4.8 0.3 360 16.7 100 10.8 9 7.2 0.45 810 11.1 100 16.2 12 9.6 0.6 1,440 8.3 100 21.6 18 14.4 0.9 3,240 5.6 100 32.4 24 19.2 1.2 5,760 4.2 100 43.2 5 4.0 0.25 62.5 80 400 6.5 6 4.8 0.3 90 66.7 400 7.8 9 7.2 0.45 202.5 44.4 400 11.7 12 9.6 0.6 360 33.3 400 15.6 18 14.4 0.9 810 22.2 400 23.4 24 19.2 1.2 1,440 16.7 400 31.2 48 38.4 2.4 5,760 8.3 400 62.4 100 70 5 16,600 6 600 110
Pick-up voltage,
V DC (max.)
Drop-out
voltage,
V DC (min.)
Coil resistance,
10%)
Nominal operat-
ing current, mA
( ± 10%)
Nominal
operating power,
mW
Max. allowable
voltage,
V DC
88
Loading...
+ 2 hidden pages