NAIS JK1aPF-9V, JK1aPF-5V, JK1aPF-48V, JK1aPF-3V, JK1aPF-24V Datasheet

...
VDE
SLIM TYPE POWER RELAY
FEATURES
21.4
.843
11
.433
15.7
.618
mm inch
• Compact & Slim design: 11.0 mm (length) × 21.4 mm (width) × 15.7 mm (height)
• High capacity type (8 A) available
• Surge resistance: Min. 8,000 V between contact and coil
• High sensitivity: 200 mW nominal operating power
• Sealed type available
• VDE, TÜV, SEMKO also approved
SPECIFICATIONS
Contact
Type Standard type Arrangement 1 Form A
Initial contact resistance, max. (By voltage drop 6 V DC 1 A)
Contact material Silver alloy
Rating (resistive load)
Nominal switching capacity
Max. switching power Max. switching voltage 250 V AC, 110 V DC (0.3 A)
3 A 30 V DC
3 A 125 V AC
90 W,
500 VA
Max. switching current 3 A 8 A
Expected life (min. operations)
Mechanical (at 180 cpm) 5 × 10 Electrical (at 20 cpm)
(at rated load)
Coil
Nominal operating power
Remarks
* Specifications will vary with foreign standards certification ratings.
1
Measurement at same location as "Initial breakdown voltage" section
*
2
*
Detection current: 10 mA
3
Wave is standard shock voltage of ± 1.2 × 50 µ s according to JEC-212-1981
*
4
*
Excluding contact bounce time
5
Half-wave pulse of sine wave: 11ms; detection time: 10 µ s
*
6
*
Half-wave pulse of sine wave: 6ms
7
*
Detection time: 10 µ s
8
Refer to 5. Conditions for operation, transpor t and storage mentioned in
*
AMBIENT ENVIRONMENT (Page 61).
Standard and high capacity type 200 mW
High capacity
100 m Ω
5 A 30 V DC
8 A 125 V AC
6
5
10
150 W,
1,250 V A
type
JK-RELAYS
(.433 × .843 × .618 inch)
Characteristics
Max. operating speed 20 cpm Initial insulation resistance* Initial
breakdown voltage*
Between open contacts 750 Vrms for 1 min. Between contact and coil 2,000 Vrms for 1 min.
2
1
Surge voltage between contact and coil* Operate time* Release time*
4
(at nominal voltage) Approx. 4 ms
4
(at nominal voltage)
(without diode) Temperature rise
(ambient temperature: 70 ° C)
Shock resistance
Functional* Destructive*
Functional*
Vibration resistance
Destructive
Conditions for operation, transport and storage*
8
(Not freezing and condensing at low temperature)
Ambient temp.
Humidity 5 to 85% R.H.
Unit weight Approx. 7 g .25 oz
Min. 100 M Ω at 500 V DC
3
Min. 8,000 V
Approx. 2 ms
Max. 45 ° C with nominal coil
voltage and at maximum allowable contact current
5
Min. 98 m/s
6
Min. 980 m/s
10 to 55 Hz at double
7
amplitude of 1.6 mm
2
{10 G}
2
{100 G}
10 to 55 Hz at double
amplitude of 2 mm
–40 ° C to +70 ° C
–40 ° F to +158 ° F
TYPICAL APPLICATIONS
• Home appliances Microwave ovens, Air conditioners
• Office equipment Photocopiers, Facsimiles
• Industrial machines NC machines
292
ORDERING INFORMATION
Ex. JK 1a P F 12 V
Contact capacity
Nil: Standard 3 A P: High capacity 8A
Notes:
1. For TV-5 rated type, add sufix “-TV”.
1. For detailed specifications, please consult us.
2. Standard packing: Carton: 100 pcs.; Case: 500 pcs.
UL/CSA, VDE approved type is standard.
Protectiive
constructiion
Nil: Sealed type F: Flux-resis­ tant type
Coil voltage
(DC)
3, 5, 6, 9, 12, 18,
24, 48 V
Ω ( ±
±
±
TYPES
1. Standard type (3 A) 2. High capacity type (8 A)
Coil voltage,
V DC
Sealed type Flux-resistant type
Part No.
3 JK1a-3V JK1aF-3V 5 JK1a-5V JK1aF-5V 6 JK1a-6V JK1aF-6V
9 JK1a-9V JK1aF-9V 12 JK1a-12V JK1aF-12V 18 JK1a-18V JK1aF-18V 24 JK1a-24V JK1aF-24V 48 JK1a-48V JK1aF-48V
Coil voltage,
V DC
Sealed type Flux-resistant type 3 JK1aP-3V JK1aPF-3V 5 JK1aP-5V JK1aPF-5V 6 JK1aP-6V JK1aPF-6V 9 JK1aP-9V JK1aPF-9V
12 JK1aP-12V JK1aPF-12V 18 JK1aP-18V JK1aPF-18V 24 JK1aP-24V JK1aPF-24V 48 JK1aP-48V JK1aPF-48V
COIL DATA (at 20 ° C 68 ° F)
Nominal voltage,
V DC
Pick-up voltage
V DC (max.)
Drop-out voltage,
V DC (min.)
Coil resistance
10%)
3 2.4 0.15 45 67 200 3.9 5 4.0 0.25 125 40 200 6.5 6 4.8 0.3 180 33 200 7.8
9 7.2 0.45 405 22 200 11.7 12 9.6 0.6 720 17 200 15.6 18 14.4 0.9 1,620 11 200 23.4 24 19.2 1.2 2,880 8.3 200 31.2 48 38.4 2.4 11,520 4.2 200 62.4
Nominal operating
current,
mA ( ± 10%)
DIMENSIONS
Part No.
Nominal operating
power,
mW
JK
Max. allowable
voltage at 70 ° C,
V DC
mm inch
REFERENCE DATA
1-(1). Maximum value for switching capacity (Standard type)
100
10
3
Contact current, A
1
AC resistive load
2.54
.100
11
.433
7.62
.300
Dimension
: General tolerance Max. 1mm .039 inch 1 to 5mm .039 to .197 inch ± 0.3 ± .012 Min. 5mm .197 inch
N.O.
21.4
.843
15.24
.600
15.4
.606
0.3
.012
4
.157
1.6
.063
2 1COM
1-(2). Maximum value for switching capacity (High capacity type)
100
10
8
Contact current, A
1
AC resistive load
PC board pattern (Copper-side view)
2-1.3 dia.
2-.051 dia.
Tolerance: ± 0.1 ± .004
0.2 ± .008
0.4 ± .016
2. Operate/release time
8
6
4
Operate/release time, ms
2
Operate time
Release time
2-0.9 dia.
2-.035 dia.
Max. –
x Max.
x Min.
Min.
10
Contact voltage, V
100 250
10
Contact voltage, V
100 250
0
80 100 120 140 160 180
Coil applied voltage, %V
293
Loading...