116
JH RELAYS
30 AMP PO WER RELAY WITH
SPACE SAVING DESIGN
VDE
mm inch
33
1.299
35.8
1.409
56
2.205
FEATURES
• Many safety-oriented characteristics
incorporated
Contact gap: more than 3 mm .118 inch
for 1 Form A and 2 Form A
Breakdown voltage for N.O. contact:
2,000 V AC between contacts
5,000 V AC between coil and contact
Molded materials: all 94 V-0
• Various contact arrangements
1 Form A, 2 Form A, 3 Form A,
2 Form A 1 Form B
• High dielectric strength for transient
protection
10,000 V surge is ms between coil and
contact
• High inrush resistance
1 Form A type: 117 A
(meets TV -8 requirement)
2 Form A type: 91 A
(meets TV -6 requirement)
VDE, TÜV also approved
SPECIFICATIONS
Contact
Coil
Characteristics
Arrangement 1 Form A 2 Form A 3 Form A 2 Form A 1 Form B
Initial contact pressure Approx. 80 g (2.82 oz) Approx. 40 g (1.41 oz) Approx. 30 g (1.06 oz) N.O.: 30 g (1.06 oz); N.C.: 20 g (0.71 oz)
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
100 m
Ω
Contact material Silver alloy
Rating
(resistive
load)
Nominal switching rating 30 A 250 V AC 20 A 250 V AC 15 A 250 V AC N.O.: 15 A 250 V AC; N.C.: 5 A 250 V AC
Max. switching power 7,500 VA 5,000 VA 3,750 VA N.O.: 3,750 VA; N.C.: 1,250 VA
Max. switching voltage 250 V AC
Max. switching current 30 A 20 A 15 A N.O.: 15 A; N.C.: 5 A
Expected
life (min.
operations)
Mechanical (at 180 cpm) 5
×
106 (106 for latching and AC types)
Electrical
(at nominal resistive load)
(at 20 cpm)
10
5
Minimum operating power 1.23 W (DC)
Nominal operating power 1.92 W (DC)
Contact arrangement 1 Form A 2 Form A 3 Form A 2 Form A 1 Form B
Maximum operating speed 20 cpm
Initial insulation resistance*
1
Min. 100 mΩ at 500 V DC
Initial
breakdown
voltage
Between open contacts 2,000 Vrms N.O.: 2,000 Vrms; N.C.: 1,500 Vrms
Between contact sets — 4,000 Vrms 3,000 Vrms 2,000 Vrms
Between contacts and coil 5,000 Vrms N.O.: 5,000 Vrms; N.C.: 3,000 Vrms
Surge voltage*
2
More than 10,000 V between contacts and coil
Temperature rise (at nominal voltage) DC: Max. 65
°
C; AC: Max. 85°C
Operate time*
3
Approx. 20 ms at nominal voltage (DC)
Release time (without diode)*
3
Approx. 5 ms at nominal voltage (DC)
Shock resistance Functional: min. 98 m/s
2
{10 G}; Destructive: min. 980 m/s2 {100 G}
Functional: Approx. 49 m/s
2
{5 G}
Destructive: min. 980 m/s
2
{100 G}
Vibration resistance Functional: 10 to 55Hz at 1 mm double amplitude Destructive: 10 to 55 Hz at 1.5 mm double amplitude
Conditions for operation,
transport and storage*
4
(Not freezing and condensing at low temperature)
Ambient temp. –50°C to +55°C (–58°F to +131°F)
Humidity 5 to 85% R.H.
Air pressure 86 to 106 kPa
Molded materials used 94 V-0
Unit weight
Approx. 90 g 3.17 oz
(Approx. 115 g 4.06 oz)
Approx. 96 g 3.39 oz
(Approx. 129 g 4.55 oz)
Approx. 100 g 3.53 oz
(Approx. 130 g 4.59 oz) ( ): screw type
Remarks
* Specifications will vary with foreign standards certification ratings.
*1Measurement of same location as "Initial breakdown voltage" section
*2 Wave is standard shock voltage of ±1.2 × 50 µs according to JEC-212-1981
*
3
Excluding contact bounce time
*4Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).