NAIS JH2a-L2-DC6V, JH2a-L2-DC48V, JH2a-L2-DC24V, JH2a-L2-DC12V, JH1a-L2-DC48V Datasheet

...
116
JH RELAYS
30 AMP PO WER RELAY WITH SPACE SAVING DESIGN
VDE
mm inch
33
1.299
35.8
1.409
56
2.205
FEATURES
• Many safety-oriented characteristics incorporated
Contact gap: more than 3 mm .118 inch
for 1 Form A and 2 Form A
Breakdown voltage for N.O. contact:
2,000 V AC between contacts 5,000 V AC between coil and contact
Molded materials: all 94 V-0
• Various contact arrangements
1 Form A, 2 Form A, 3 Form A, 2 Form A 1 Form B
• High dielectric strength for transient protection
10,000 V surge is ms between coil and contact
• High inrush resistance
1 Form A type: 117 A (meets TV -8 requirement) 2 Form A type: 91 A (meets TV -6 requirement)
VDE, TÜV also approved
SPECIFICATIONS
Contact
Coil
Characteristics
Arrangement 1 Form A 2 Form A 3 Form A 2 Form A 1 Form B Initial contact pressure Approx. 80 g (2.82 oz) Approx. 40 g (1.41 oz) Approx. 30 g (1.06 oz) N.O.: 30 g (1.06 oz); N.C.: 20 g (0.71 oz) Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
100 m
Contact material Silver alloy
Rating (resistive load)
Nominal switching rating 30 A 250 V AC 20 A 250 V AC 15 A 250 V AC N.O.: 15 A 250 V AC; N.C.: 5 A 250 V AC Max. switching power 7,500 VA 5,000 VA 3,750 VA N.O.: 3,750 VA; N.C.: 1,250 VA Max. switching voltage 250 V AC Max. switching current 30 A 20 A 15 A N.O.: 15 A; N.C.: 5 A
Expected life (min. operations)
Mechanical (at 180 cpm) 5
×
106 (106 for latching and AC types)
Electrical (at nominal resistive load) (at 20 cpm)
10
5
Minimum operating power 1.23 W (DC) Nominal operating power 1.92 W (DC)
Contact arrangement 1 Form A 2 Form A 3 Form A 2 Form A 1 Form B Maximum operating speed 20 cpm Initial insulation resistance*
1
Min. 100 mΩ at 500 V DC
Initial breakdown voltage
Between open contacts 2,000 Vrms N.O.: 2,000 Vrms; N.C.: 1,500 Vrms Between contact sets 4,000 Vrms 3,000 Vrms 2,000 Vrms Between contacts and coil 5,000 Vrms N.O.: 5,000 Vrms; N.C.: 3,000 Vrms
Surge voltage*
2
More than 10,000 V between contacts and coil
Temperature rise (at nominal voltage) DC: Max. 65
°
C; AC: Max. 85°C
Operate time*
3
Approx. 20 ms at nominal voltage (DC)
Release time (without diode)*
3
Approx. 5 ms at nominal voltage (DC)
Shock resistance Functional: min. 98 m/s
2
{10 G}; Destructive: min. 980 m/s2 {100 G}
Functional: Approx. 49 m/s
2
{5 G}
Destructive: min. 980 m/s
2
{100 G} Vibration resistance Functional: 10 to 55Hz at 1 mm double amplitude Destructive: 10 to 55 Hz at 1.5 mm double amplitude Conditions for operation,
transport and storage*
4
(Not freezing and condens­ing at low temperature)
Ambient temp. –50°C to +55°C (–58°F to +131°F) Humidity 5 to 85% R.H.
Air pressure 86 to 106 kPa
Molded materials used 94 V-0 Unit weight
Approx. 90 g 3.17 oz
(Approx. 115 g 4.06 oz)
Approx. 96 g 3.39 oz
(Approx. 129 g 4.55 oz)
Approx. 100 g 3.53 oz
(Approx. 130 g 4.59 oz) ( ): screw type
Remarks
* Specifications will vary with foreign standards certification ratings. *1Measurement of same location as "Initial breakdown voltage" section *2 Wave is standard shock voltage of ±1.2 × 50 µs according to JEC-212-1981
*
3
Excluding contact bounce time
*4Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
JH
117
TYPICAL APPLICATIONS
Air conditioners, microwave ovens, load management equipment, copiers, pro­cess control equipment.
ORDERING INFORMATION
2a L2 DC24VEx. JH
Contact arrangement
1a: 1 Form A 2a: 2 Form A 3a: 3 Form A 2a1b: 2 Form A 1 Form B
Nil: Plug-in terminal type
DC 6, 12, 24, 48, 110 V
Nil: Single side stable for 3 Form A,
W: 2 Form A 1 Form B
L2: 2 coil latching for 1 Form A, 2 Form A WL2: 2 coil latching for 3 Form A,
2 Form A 1 From B
Terminals Operating function
(Notes) 1. For UL/CSA recognized type, please add suffix UL/CSA.
(Notse) 2. Standard Packing: Carton 20 pcs, Case 100 pcs.
Coil voltage
TYPES AND COIL DATA
Single side stable (DC coils at 20°C 68°F): DC types of JH3a-W and JH2a1b-W
2 coil latching (DC coils only at 20°C 68°F): DC types of JH1a-L2, JH2a-L2 and JH3a-WL2
Nominal voltage,
V DC
Pick-up voltage Drop-out voltage
Maximum allowable
voltage, at 50°C
Coil resistance (ohm)
Nominal operating
power, (W)
6
Less than 80% of
nominal voltage
More than 10% of
nominal voltage
110% of
nominal voltage
18.7 1.92 12 75 1.92 24 300 1.92 48 1,200 1.92
110 6,300 1.92
Nominal voltage,
V DC
Set and reset voltage
Maximum allowable
voltage, at 50°C
Coil resistance, (Ω) Nominal operating power, (W)
Coil I Coil II Coil I Coil II
6
Less than 80% of
nominal voltage
110% of
nominal voltage
18.7 18.7 1.92 1.92 12 75 75 1.92 1.92 24 300 300 1.92 1.92 48 1,200 1,200 1.92 1.92
110 6,300 6,300 1.92 1.92
Notes:
1. Coil resistance varies ±10% for less than 1,000 W, and ±15% for more than 1,000 Ω. For each ±1°C change in ambi­ent temperature, coil resistance varies
±
0.4%.
2. For each ±1°C change in ambient tem­perature, pick-up and drop-out voltages vary approximately ±0.4%.
3. Pic k-up and drop-out voltages are mea­sured with the relay mounted as follows.
4. The coil operating current should be pure direct current in principle. When rec­tified alternating current is applied to the coil, the relay characteristics (pick-up, drop-out voltage) may be changed due to the ripple factor. Confirmation of the char­acteristics in the actual circuit is suggest­ed.