NAIS AGN210S4HZ, AGN210S4HX, AGN210S4H, AGN210S24Z, AGN210S24 Datasheet

...
GN
125
GN-RELAYS
5.70±0.3
.224±.012
10.60±0.3
.417±.012
9.00±0.3
.354±.012
5.70±0.3
.224±.012
10.60±0.3
.417±.012
Max.10.00
.394
mm inch
FEATURES
• Compact slim body saves space
Thanks to the small surface area of 5.7 mm × 10.6 mm .224 inch × .417 inch and low height of 9.0 mm .354 inch, the pack­aging density can be increased to allow for much smaller designs.
• Outstanding surge resistance.
Surge withstand between open contacts: 1,500 V 10 × 160 µ s (FCC part 68) Surge withstand between contacts and coil: 2,500 V 2 × 10 µ s (Bellcore)
• The use of twin cr ossbar contacts en­sures high contact reliability.
AgPd contact is used because of its good sulfide resistance. Adopting low-gas molding material. Coil assembly molding technology which avoids generating vola­tile gas from coil.
• Increased packaging density
Due to highly efficient magnetic circuit de­sign, leakage flux is reduced and changes in electrical characteristics from compo­nents being mounted close-together are minimized. This all means a packaging density higher than ever before.
• Nominal operating power: 140 mW
• Outstanding vibration and shock re­sistance.
Functional shock resistance: 750 m/s
2
{75G} Destructive shock resistance: 1,000 m/s
2
{100G} Functional vibration resistance: 10 to 55 Hz (at double amplitude of 3.3 mm .130 inch) Destructive vibration resistance: 10 to 55 Hz (at double amplitude of 5 mm
.197 inch)
SPECIFICATIONS
Contact
Remarks:
* Specifications will vary with foreign standards certification ratings. *
1
Measurement at same location as "Initial breakdown voltage" section.
*
2
Detection current: 10mA.
*
3
Nominal voltage applied to the coil, excluding contact bounce time.
*
4
By resistive method, nominal voltage applied to the coil; contact carrying current: 1 A.
*
5
Half-wave pulse of sine wave: 6 ms; detection time: 10 µ s.
*
6
Half-wave pulse of sine wave: 6 ms.
*
7
Detection time: 10 µ s.
*
8
Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61)
Characteristics
Notes:
1 This value can change due to the switching frequency , environmental conditions ,
and desired reliability level, therefore it is recommended to check this with the actual load.
2 The upper limit for the ambient temperature is the maximum temperature that
can satisfy the coil temperature rise. Under the packing condition, allowable temperature range is from –40 to +70 ° C –40 ° to +158 ° F.
Arrangement 2 Form C Initial contact resistance, max.
(By voltage drop 6 V DC 1A )
100 m Ω
Contact material
Stationary: AgPd+Au clad
Movable: AgPd
Rating
Nominal switching capacity (resistive load)
1 A 30 V DC
0.3 A 125 V AC
Max. switching power (resistive load)
30 W, 37.5 V A
Max. switching voltage 110 V DC, 125 V AC Max. switching current 1 A Min. switching capacity ❇ 1 10 µ A 10 mV DC
Nominal operating power
Single side stable
140mW (1.5 to 12 V DC)
230mW (24 V DC)
1 coil latching
100mW (1.5 to 12 V DC)
120mW (24 V DC)
Expected life (min. operations)
Mechanical (at 180 cpm) 5 × 10
7
Electrical (at 20 cpm)
1 A 30 V DC resistive
10
5
0.3 A 125 V AC resistive
10
5
Initial insulation resistance*
1
Min. 1,000M Ω (at 500V DC)
Initial breakdown voltage*
2
Between open contacts 750 Vrms for 1min. Between contact sets 1,000 Vrms for 1min. Between contacts and coil 1,500 Vrms for 1min.
Initial surge voltage
Between open contacts (10 × 160 µ s)
1,500 V (FCC Part 68)
Between contacts and coil (2 × 10 µ s)
2,500 V (Bellcore)
Operate time [Set time]*
3
(at 20 ° C)
Max. 4 ms (Approx. 2 ms)
[Max. 4 ms (Approx. 2 ms)]
Release time (without diode) [Reset time]*
3
(at 20 ° C)
Max. 4 ms (Approx. 1 ms)
[Max. 4 ms (Approx. 2 ms)]
Temperature rise*
4
(at 20 ° C) Max. 50 ° C
Shock resistance
Functional*
5
Min. 750 m/s
2
{75G]
Destructive*
6
Min. 1,000 m/s
2
{100G]
Vibration resistance
Functional*
7
10 to 55 Hz at double
amplitude of 3.3 mm
Destructive
10 to 55 Hz at double
amplitude of 5 mm
Conditions for opera­tion, transport and storage*
8
(Not freezing and con­densing at low tem­perature)
Ambient temperature ❇ 2
–40 ° C to 85 ° C
–40 ° F to 185 ° F
Humidity 5 to 85% R.H.
Unit weight Approx. 1 g.035 oz
TESTING
GN
126
TYPICAL APPLICATIONS
• Telephone exchange, transmission equipment
• Communications devices
• Measurement devices
• Home appliances, and audio/visual equipment
• Handheld and portable products
ORDERING INFORMATION
200A Z1HEx. AGN
Contact arrangement
Terminal shapeOperating function Packing style
Coil voltage (DC)
Nil: Standard PC board terminal A: Surface-mount terminal A type S: Surface-mount terminal S type
2: 2 Form C 0: Single side stable
1: 1 coil latching
Type of operation
0: Standard type
(B.B.M.)
Nil: Tube packing Z:
Tape and reel packing (piked from 5/6/7/8 pin side)
1H: 1.5V 03 : 3V 4H: 4.5V 06 : 6V
09 : 9V 12 : 12V 24 : 24V
Note: Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/2/3/4-pin side) is also available. Suffix “X” instead of “Z”.
TYPES AND COIL DATA (at 20 ° C 68 ° F)
(1) Standard PC board terminal
1) Standard packing: 50 pcs. in an inner package (tube); 1,000 pcs. in an outer package
2) Specified value of pick-up, drop-out, set and reset voltage is with the condition of square wave coil pulse.
(2) Surface-mount terminal
: For each surface-mounted terminal variation, input the following letter.
A type: A
, S type: S
1) Standard packing: 50 pcs.(tube), 500pcs. (tape and reel)in an inner package; 1,000 pcs. in an outer package
2) Specified value of pick-up, drop-out, set and reset voltage is with the condition of square wave coil pulse.
Operating Function
Part No.
Coil Rating,
V DC
Pick-up volt-
age, V DC
(max.) (initial)
Drop-out
voltage,
V DC (min.)
(initial)
Nominal
operating
current,
mA ( ± 10%)
Coil resistance,
Ω ( ±
10%)
Nominal
operating
power, mW
Max. allowable
voltage,
V DC
Standard PC
board terminal
Single side stable
AGN2001H 1.5 1.13 0.15 93.8 16 140 2.25 AGN20003 3 2.25 0.3 46.7 64.2 140 4.5 AGN2004H 4.5 3.38 0.45 31 145 140 6.75 AGN20006 6 4.5 0.6 23.3 257 140 9 AGN20009 9 6.75 0.9 15.5 579 140 13.5 AGN20012 12 9 1.2 11.7 1,028 140 18 AGN20024 24 18 2.4 9.6 2,504 230 28.8
Operating Function
Part No.
Coil Rating,
V DC
Set voltage,
V DC (max.)
(initial)
Reset voltage,
V DC (max.)
(initial)
Nominal
operating
current,
mA ( ± 10%)
Coil resistance,
Ω ( ±
10%)
Nominal
operating
power, mW
Max. allowable
voltage,
V DC
Standard PC
board terminal
1 coil latching
AGN2101H 1.5 1.13 1.13 66.7 22.5 100 2.25 AGN21003 3 2.25 2.25 33.3 90 100 4.5 AGN2104H 4.5 3.38 3.38 22.2 202.5 100 6.75 AGN21006 6 4.5 4.5 16.7 360 100 9 AGN21009 9 6.75 6.75 11.1 810 100 13.5 AGN21012 12 9 9 8.3 1,440 100 18 AGN21024 24 18 18 5.0 4,800 120 36
Operating Function
Part No.
Coil Rating,
V DC
Pick-up
voltage,
V DC (max.)
(initial)
Drop-out
voltage,
V DC (min.)
(initial)
Nominal
operating
current,
mA ( ± 10%)
Coil
resistance,
Ω ( ±
10%)
Nominal
operating
power,
mW
Max.
allowable
voltage,
V DC
Tube packing
Tape and reel
packing
Single side stable
AGN200 ❍ 1H AGN200 ❍ 1HZ 1.5 1.13 0.15 93.8 16 140 2.25 AGN200 ❍ 03 AGN200 ❍ 03Z 3 2.25 0.3 46.7 64.2 140 4.5 AGN200 ❍ 4H AGN200 ❍ 4HZ 4.5 3.38 0.45 31 145 140 6.75 AGN200 ❍ 06 AGN200 ❍ 06Z 6 4.5 0.6 23.3 257 140 9 AGN200 ❍ 09 AGN200 ❍ 09Z 9 6.75 0.9 15.5 579 140 13.5 AGN200 ❍ 12 AGN200 ❍ 12Z 12 9 1.2 11.7 1,028 140 18 AGN200 ❍ 24 AGN200 ❍ 24Z 24 18 2.4 9.6 2,504 230 28.8
GN
127
: For each surface-mounted terminal variation, input the following letter.
A type: A
, S type: S
1) Standard packing: 50 pcs.(tube), 500pcs. (tape and reel)in an inner package; 1,000 pcs. in an outer package
2) Specified value of pick-up, drop-out, set and reset voltage is with the condition of square wave coil pulse.
Operating Function
Part No.
Coil Rating,
V DC
Set voltage,
V DC (max.)
(initial)
Reset
voltage,
V DC (max.)
(initial)
Nominal
operating
current,
mA ( ± 10%)
Coil
resistance,
Ω ( ±
10%)
Nominal
operating
power,
mW
Max.
allowable
voltage,
V DC
Tube packing
Tape and reel
packing
1 coil latching
AGN210 ❍ 1H AGN210 ❍ 1HZ 1.5 1.13 1.13 66.7 22.5 100 2.25 AGN210 ❍ 03 AGN210 ❍ 03Z 3 2.25 2.25 33.3 90 100 4.5 AGN210 ❍ 4H AGN210 ❍ 4HZ 4.5 3.38 3.38 22.2 202.5 100 6.75 AGN210 ❍ 06 AGN210 ❍ 06Z 6 4.5 4.5 16.7 360 100 9 AGN210 ❍ 09 AGN210 ❍ 09Z 9 6.75 6.75 11.1 810 100 13.5 AGN210 ❍ 12 AGN210 ❍ 12Z 12 9 9 8.3 1,440 100 18 AGN210 ❍ 24 AGN210 ❍ 24Z 24 18 18 5.0 4,800 120 36
DIMENSIONS
1. PC board terminal
10.60±0.3
.417±.012
5.70±0.3
.224±.012
0.40±0.1
.016±.004
(1.50)
(.059)
2.20±0.15
.087±.006
3.20±0.15
.126±.006
0.25±0.1
.010±.004
3.20±0.15
.126±.006
3.50±0.3
.138±.012
(0.50)
(.020)
9.00±0.3
.354±.012
PC board pattern
Tolerance: ± 0.1 ± .004
3.20
.126
2.20
.087
7.60
.299
3.20
.126
8-0.85 dia.
8-.033 dia
Schematic (Bottom view)
Single side stable
(Deenergized condition)
1 coil latching
(Reset condition)
Direction indication
8 765
1 234
Direction indication
45278163
mm inch
2. Surface-mount terminal
1) A type
10.60±0.3
.417±.012
5.70±0.3
.224±.012
0.40±0.1
.016±.004
(1.50)
(.059)
3.20±0.15
.126±.006
3.20±0.15
.126±.006
0.25±0.1
.010±.004
2.20±0.15
.087±.006
7.40±0.3
.291±.012
(0.50)
(.020)
9.00±0.3
.354±.012
Max. 10.00
.394
Suggested mounting pad
Tolerance: ±0.1 ±.004
2.20
.087
3.20
.126
5.30
.209
3.10
.122
0.80
.031
1) S type
10.60±0.3
.417±.012
5.70±0.3
.224±.012
3.20±0.15
.126±.006
0.40±0.1
.016±.004
(1.50)
(.059)
0.25±0.1
.010±.004
3.20±0.15
.126±.006
2.20±0.15
.087±.006
5.70±0.3
.224±.012
(0.50)
(.020)
9.00±0.3
.354±.012
Max. 10.00
.394
Suggested mounting pad
Tolerance: ±0.1 ±.004
2.20
.087
3.20
.126
4.45
.175
2.25
.089
0.80
.031
Schematic (Top view)
Single side stable
(Deenergized condition)
1 coil latcing
(Reset condition)
Direction indication
1 234
8 765
Direction indication
5678
2134
REFERENCE DATA
1. Max. switching capacity 2. Life curve
30
100
Contact voltage, V
1.0
0.3
DC resistive load AC resistive load
Switching current, A
Switching current, A
No. of operations, × 10
4
0.2 0.4 0.6 0.8 1.0 1.2
100
50
30
40
20
10
0
DC 30V resistive load
AC 125V resistive load
GN
128
NOTES
1. Coil operating power
1) As a general rule, only a pure DC pow­er supply should be used for the coil drive.
2) To ensure proper operation, the voltage applied to both terminals of the coil should be ±5% (at 20°C 68°F) the rated operating voltage of the coil. Also , be aware that the pick-up and drop-out voltages will fluctu­ate depending on the ambient tempera­ture and operating conditions.
3) The ripple factor f or the voltage applied to the coil should be less than 5%.
4) For set and reset latching relays, the rated operating voltage should be applied to the coil for 10 ms or more.
2. Coil connection
When connecting coils, refer to the wiring diagram to prevent mis-operation or mal­function.
3. External magnetic field
Since GN relays are highly sensitive po­larized relays, their characteristics will be affected by a strong external magnetic field. A v oid using the rela y under that con­ditions.
4. Cleaning
In automatic cleaning, cleaning with the boiling method is recommended. A v oid ul­trasonic cleaning which subjects the relay to high frequency vibrations. It may cause the contacts to stick. lt is recommended that a fluorinated hy­drocarbon or other alcoholic solvent be used.
5. Packing style
1) The relay is packed in a tube with the relay orientation mark on the left side, as shown in the figure below.
2) Tape and reel packing
(A type) (1)-1 T ape dimensions
mm inch
(S type) (1)-2 T ape dimensions
(2) Dimensions of plastic peel
mm inch
6. Automatic insertion
To maintain the internal function of the relay, the chucking pressure should not exceed the values below. Chucking pressure in the direction A:
4.9 N {500gf} or less
Chucking pressure in the direction B:
9.8 N {1 kgf} or less
Chucking pressure in the direction C:
9.8 N {1 kgf} or less
Please chuck the portion. Avoid chucking the center of the relay. In addition, excessive chucking pressure to the pinpoint of the relay should be avoided.
Orientation (indicates PIN No.1)stripe
Stopper (green) Stopper (red)
Relay polarity bar (Z type)
Tape coming out direction
General tolerance ±0.1 mm .004 inch
4.00
.157
1.75
.069
0.40
.016
10.70±0.2
.421±.008
2.00
.079
2.00dia
.079dia
GN relays
16.00
.630
8.00
.315
11.50
.453
24.00±0.3
.945±.012
11.10
.437
1.50
+0.1 0
dia
.059
+.004 0
dia
Relay polarity bar (Z type)
Tape coming out direction
General tolerance ±0.1 mm .004 inch
1.50
+0.1 0
dia
.059
+.004 0
dia
2.0dia
.079dia
4.00
.157
1.75
.069
10.70±0.2
.421±.008
0.40
.016
2.00
.079
GN relays
16.00
.630
6.3
.248
11.50
.453
11.10
.437
24.00±0.3
.945±.012
21±0.8 dia.
.827±.031 dia.
13±0.2 dia.
.512±.008 dia.
24.4
.961
+2 0
+.079 0
100±1 dia.
3.937±.039 dia.
2.0±0.2
.079±.008
370±2 dia.
14.567±.079 dia.
2.0±0.5
.079±.020
A
C
B
For Cautions for Use, see Relay Technical Information (Page 48 to 76).
9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.
Go To Online Catalog
Loading...