Featuring a full 30 Watt output in 1.8 square inches of board area,
the UEI series isolated DC/DC converter family offers efficient
regulated DC power for printed circuit board mounting.
Typical unit
ical unit
FEATURES
Small footprint DC/DC converter, ideal for high
current applications
0.92" x 1.92" x 0.35" open frame package
Wide range input voltages 9-36 and 18-75Vdc
Double lead-free assembly and attachment
for RoHS standards
Isolation up to 2250 VDC (basic)
Up to 30W total output power with
overtemperature shutdown
High effi ciency synchronous rectifi er forward
topology
Stable no-load operation with no required
external components
–40 to +85°C temperature range with derating
Designed to meet UL60950-1, CSA-C22.2 No.
234, EN60950-1 safety approvals
Extensive self-protection shut down features
RoHS hazardous substance compliant
PRODUCT OVERVIEW
Wide range 4:1 inputs on the 0.92" x 1.92" x 0.35"
converter are either 9 to 36 Volts DC (Q12
models) or 18 to 75 Volts DC (Q48 models), ideal
for battery-powered and telecom equipment.
Fixed output voltages from 3.3 VDC to 15 VDC
are tightly regulated and may be trimmed within
±10% of nominal output. Applications include
small instruments, computer-based systems,
data communications equipment, remote sensor
systems, vehicle and portable electronics.
The UEI 30W Series includes full magnetic and
optical isolation up to 2250 Volts DC (basic insulation). For connection to digital systems, the outputs offer fast settling to current step loads and
tolerance of higher capacitive loads. Excellent
ripple and noise specifi cations assure compatibility to circuits using CPU’s, ASIC’s, programmable
logic and FPGA’s. No minimum load is required.
For systems requiring controlled startup/shutdown, an external switch, transistor or digital
SIMPLIFIED SCHEMATIC
logic may be used to activate the remote On/Off
control. Remote Sense inputs compensate for
resistive line drops at high currents.
A wealth of self-protection features avoid
both converter and external circuit problems.
These include input undervoltage lockout and
overtemperature shutdown. The outputs current
limit using the “hiccup” autorestart technique and
the outputs may be short-circuited indefi nitely.
Additional features include output overvoltage
and reverse conduction elimination.
The synchronous rectifi er forward topology
offers high effi ciency for minimal heat buildup
and “no fan” operation. The open frame design
is also available under special quantity order
with an encapsulation shell and thermallyconductive potting compound. This option offers
additional cooling in low-airfl ow, high temperature applications.
c Please refer to the part number structure for additional options and complete ordering part numbers.
d All specifi cations are at nominal line voltage and full load, +25 deg.C. unless otherwise noted. See
detailed specifi cations.
c
PowerR/N (mVp-p) Regulation (Max.)
IOUT
(A)
(W)Typ.Max.LineLoad
Please contact Murata Power
Solutions for further information.
Please contact Murata Power
Solutions for further information.
VIN
Range
Nom.
(V)
e Sense input is not included for 12 Vout and higher models. Sense is optional for 5 Vout and lower.
(V)
249-36
249-36
Output capacitors are 1 μF ceramic in parallel with 10 μF electrolytic. Input cap is 22 μF, low ESR.
These I/O caps are necessary for our test equipment and may not be needed for your application.
IIN,
no load
IIN, full
load (A)
(mA)
Please contact Murata Power
Solutions for further information.
Please contact Murata Power
Solutions for further information.
Effi ciency
Min.Typ.
Open Frame
Package, C80
Case (inches)Pinout
0.92x1.92x0.35P21
0.92x1.92x0.35P21
0.92x1.92x0.35
P21
PART NUMBER STRUCTURE
UEI30 -Q48-050
Nominal Output Voltage
In tenths of a volt
Input Voltage Range:
Q12 = 9-36V
Q48 = 18-75V
C
-N
RoHS-6 hazardous substancecompliance
Note:
Not all model number combinations are
available. Contact Murata Power Solutions.
On/Off Control Polarity:
P = Positive
N = Negative
Positive “P” polarity is standard for Q12 models and optional special
order for Q48 models. Negative “N” polarity is standard for Q48
models and optional special order for Q12 models.
Soldering Guidelines
Murata Power Solutions recommends the specifi cations below when installing these converters. These specifi cations vary depending on the solder type. Exceeding these specifi cations may cause damage to the product. Be cautious when there is high atmospheric humidity. We strongly recommend a mild pre-bake (100° C. for 30 minutes). Your production
environment may differ; therefore please thoroughly review these guidelines with your process engineers.
Wave Solder Operations for through-hole mounted products (THMT)
For Sn/Ag/Cu based solders:For Sn/Pb based solders:
Maximum Preheat Temperature 115° C.Maximum Preheat Temperature 105° C.
Maximum Pot Temperature270° C.Maximum Pot Temperature250° C.
Maximum Solder Dwell Time7 secondsMaximum Solder Dwell Time6 seconds
50 VDC, no damage
0-75 VDC to rated specifi cations
Current-limited. Devices can
withstand sustained short circuit
without damage. The outputs are
not intended to accept appreciable reverse current.
Device includes electronic overtemperature shutdown protection
under normal operation.
-55 to +125° C.
Capacitive Loading Max.
Low ESR <0.02Ω Max,
resistive load
OUT nom. +20% max.
Overvoltage
protection
Hiccup auto-start
after fault removal
5.0
Absolute Maximum Ratings
Absolute maximums are stress ratings. Exposure of devices to
greater than any of these conditions may adversely affect long-term
reliability. Proper operation under conditions other than those listed
in the Performance/Functional Specifi cations Table is not implied nor
recommended.
Maximum Ratings Notes
The UEI-30W series does not include electronic Input Overvoltage
Protection. Therefore it is possible for the input to exceed the continuous ratings listed above and still operate. However, units are not
routinely Production-tested above the continuous ratings. Therefore,
the rated specifi cations do not apply at excessive input voltage and
performance is undetermined.
At some combinations of high ambient temperature, low airfl ow
or high output current, the controller may shut down from overtemperature if the maximum rated input voltage is exceeded.
The transient specifi cations indicate that sample lots were successfully tested for 100 mS at the transient stress voltage and were
not damaged. As a practical matter in your application, it is often
diffi cult to determine how long an input overvoltage was applied.
Therefore, do not exceed the continuous voltage rating.