Mr. Steam MSBUTLER1RDRAW, MSITEMPORDBN, MSBUTLER1SQWH, CT15EC1I3BK, 90C1ATRDPC Installation Manual

...
Installation, Operation & Maintenance Manual
iTEMPO™ & iTEMPOPLUS™ CONTROLS
mr.steam
www.mrsteam.com
Feel Good Inc.
When installing and using this electrical equipment, basic safety precau-
tions should always be followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS
1. READ AND FOLLOW ALL INSTRUCTIONS
WARNING
!
2. Do not permit children under the age of 16 to use this steambath.
WARNING
3. Steam is hot and can cause injury or death if
!
improperly used. Steam rooms contain steam and elevated tem­peratures. Please read and observe all warnings in this manual before installing or using a steam room.
4. To reduce the risk of injury:
WARNING
!
A. The wet surfaces of steam enclosures may be slippery. Use
care when entering or leaving.
B. The steam head is hot. Do not touch the steamhead and avoid
the steam near the steamhead.
C. Prolonged use of the steam system can raise excessively the
internal human body temperature and impair the body’s abil­ity to regulate its internal temperature (hyperthermia). Limit your use of steam to 10-15 minutes until you are certain of your body’s reaction.
D. Excessive temperatures have a high potential for causing fetal
damage during the early months of pregnancy. Pregnancy or possibly pregnant women should consult a physician regarding correct exposure.
E. Obese persons and persons with a history of heart disease, low or
high blood pressure, circulatory system problems, or diabetes should consult a physician before using a steambath.
F. Persons using medication should consult a physician before using
a steambath since some medication may induce drowsiness while other medications may affect heart rate, blood pressure and circulation.
HYPERTHERMIA
internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6° F. The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include:
a) Failure to perceive heat;
b) Failure to recognize the need to exit the steambath;
c) Unawareness of impending risk;
d) Fetal damage in pregnant women;
e) Physical inability to exit the steam­bath; and
f) Unconsciousness.
WARNING
!
The use of alcohol, drugs, or medication can greatly increase the risk of hyperthermia.
occurs when the
SAVE THESE INSTRUCTIONS
2
mr.steam
______________________________________________________________
®
Installation & Operating Instructions
READ ME FIRST!
WARNING
!
As you follow these instruc-
tions, you will notice warning and caution symbols. This blocked information is impor­tant for the safe and efficient installation and operation of this generator. These are types of potential hazards that may occur during installation and operation:
WARNING
!
Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury.
Indicates a potentially
CAUTION
!
hazardous situation, which, if not avoided may result in minor or moderate injury or product damage.
IMPORTANT NOTE: This highlights information that is especially relevant to a problem-free installation.
All information in these instructions is based on the latest product information available at the time of publication. Sussman-Automatic Corporation reserves the right to make changes at any time without notice.
Table of Contents:
Important Safety Instructions .............................. 2
Before Installing .................................................. 4
Dimensional Information .................................... 5
Installations ...................................................... 6-8
Installing the Remote Temperature Probe ....9-11
iTempo Operating Instructions ...................12-13
iTempoPlus Operating Instructions ............. 14-17
Care and Maintenance ..................................... 18
Warranty ........................................................... 18
3
mr.steam
______________________________________________________________
®
Installation & Operating Instructions
BEFORE INSTALLING
Carefully inspect the control and packaging for ship­ping damage. In the event of shipping damage, please contact the carrier for claim information. Our customer service department can assist you with any missing or damaged parts.
CAUTION
!
To avoid unintentional steambath op­eration, do not locate the control where other controls, accessories, shower heads, valves, body sprays or simi­lar within the shower could cause confusion or interfere with the Mr.Steam
Do not use any iTempoPlus or iGenie the respective Installation and Operation Manual and Mr.Steam steam generator Installation and Operation Manual (PN 101289 Revision number 10.0/08 or higher). Failure to read and understand these instructions may result in an inoperative or hazardous installation.
WARNING
A peel and stick warning sticker is
!
provided in the MrSteam steam generator Installation, Operation and Maintenance Manual. This manual is provided with every steam generator. The warning sticker must be read and permanently affixed in a conspicuous location near the steam room. Failure to read and affix this warning sticker in a conspicuous location may result in serious injury or death. Please call MrSteam at 800 767-8326 for a free replacement or if you have any questions regarding the warning sticker.
Install the iTempo or iTempoPlus controls according to installation instructions. Failure to install according to instructions will result in an inoperative control or haz­ardous overheating or inadequate heating of the steam room. If an iTempo or iTempoPlus control is installed outside the steam room a Remote Temperature Probe (PN MSTS) must be installed inside the steam room
®
control’s intended use and function.
®
controls without reading and understanding
, iTempo™, HomeWizard™
per instructions for the Remote Temperature Probe. Failure to install according to instructions will result in an inoperative control and overheating of the steam room.
WARNING
Do not route iTempoPlus, iTempo,
!
Home Wizard or iGenie control wiring inside conduit together with power lines or close to hot water or steam piping. Doing so may result in an inoperative or hazardous installation.
WARNING
Do not alter or modify any Mr. Steam
!
product. Doing so may result in an inoperative or haz­ardous installation and will void the warranty.
IMPORTANT NOTES:
• Turn power to the steam generator OFF before con­necting the control to the generator. Failure to turn the power off will result in an inoperable control.
• Do not operate iTempoPlus, iTempo, Home Wiz­ard or iGenie controls with anything other than a Mr.Steam iTempo compatible steam generator. Mr.Steam residential steam generators with serial numbers lower than 900000, or any other brand of steam generator are not to be operated with iTempo controls. Doing so may result in an inoperative installation.
• This document contains important safety, operation and maintenance information. Leave this document with the homeowner. Do not discard this document.
• Discontinue use of the steam generator or control if the steam generator is damaged or oth­erwise not functioning properly. Doing so may result in an inoperative or hazardous installation.
• All illustrations are for illustrative purposes only.
4
mr.steam
______________________________________________________________
®
Installation & Operating Instructions
Dimensional Information for the Round and Square iTempo
and iTempoPlus
BOX CONTENTS:
• iTempo™ or iTempoPlus™ Control
• Control Cable (30 ft.)
• Steam head
• Tube of Silicone Sealant
• Owner’s Manual
1
4
/
2
1
2
/
2
5”
5”
1”
3
/
8
1
/
4
3
/
4
3
3
/
4
12” long pigtail
Drawings for Illustrative Purposes Only.
5
mr.steam
______________________________________________________________
®
Installation & Operating Instructions
Installation Instructions for Round & Square iTempo
and iTempoPlus
STEP 1
Determine the desired installation location of the control. The iTempo installed inside or outside the steam room as a matter of personal preference. If the control is installed outside the steam room a Remote Temperature Probe part number MSTS must be installed inside the steam room. If the control is installed inside the steam room the control must be located:
• 4-5 feet above the oor near the bather seating area.
• The control features an integral temperature sensor. Locate
• On a vertical wall
• The control cable length is 30 feet. Insure that the control and/or steam
generator are located accordingly. Contact a Mr.Steam technical service representative if a longer cable is required (60 ft. cable, PN 103990-60).
IMPORTANT NOTE: The control cable should be run in a dedicated
1” conduit to facilitate installation and service.
IMPORTANT NOTE: See installation instructions for the MSTS
Temperature Probe before rough-in or installation of control (pgs. 8-9).
STEP 2
Make a 2-5⁄8” wide by 3-7⁄8” high cutout in the desired control location. Do not oversize or under size the cutout.
STEP 3
Route the control cable (provided with the control) from the wall cutout to the steam generator. Connect one end of the cable to the steam generator connector.
and iTempoPlus
the control in a location representative of the desired steam bathing temperatures. Do not locate the control above or near the steam head or direct steam emissions. Locating the controls near the steamhead or near direct steam emissions may result in poor steam room temperature control.
Diagram 1
Diagram 2
controls are designed to be
6