Technical Specifications
Linear Steam Head
• Quiet, even distribution of steam
• No field assembly required
• No moving parts
• Minimal profile
Linear Steamhead
Installation
IMPORTANT: Do not disassemble steam-
head. MrSteam’s steamhead is shipped
fully assembled and requires no additional
assembly.
Locate steamhead 6-12 inches above
floor, except for tub/shower enclosures;
install 6 inches above tub top edge.
CAUTIONS
!
• Because the steamhead and direct
steam emissions are very hot, locate
the steamhead where incidental
contact by bather with the steamhead or direct steam emission
cannot occur.
• Consult local building codes when
installing 104217 & 104218. Codes
may require the use of headers,
jack studs, king studs and/or cripple
studs.
• Linear steamheads shall only be
used with the model listed in the
chart on page 2. Using Linear
steamheads for any steam generator
model larger than those listed or for
any non MrSteam brand generators
may result in an improper
installation or hazardous condition.
• Install in a horizontal orientation only.
Installation in a vertical orientation
may concentrate the steam and result
in excessive temperatures.
MODEL PROJECT INFORMATION
I
I
I
I
Notes:
104217:
104218:
mr.steam
43-20 34th Street, Long Island City, NY 11101 TEL: 1 800 76 STEAM FAX: 718 472 3256
9410 S. La Cienega Blvd. Inglewood CA 90301 TEL: 1 800 72 STEAM FAX: 310 216 2944
NPT)
(3⁄4"
CU360-CU1400
CU2000-CU4500
®
Sussman-Automatic Corp®hello@mrsteam.com www.mrsteam.com
FOR ILLUSTRATIVE PURPOSES ONLY.
TROUBLE FREE INSTALLATION visit mrsteam.com or scan the QR code before
installation to download the Installation, Operation and Maintenance Manual or
refer to the manual provided with the unit.
Location:
Architect:
Engineer:
104217 & 104218
Model ABC
104217 6
104218 10
Generator Model Steam Head Steam Emission Zone
CU360– CU1400 104217 24”
CU2000-CU4500 104218 32”
IMPORTANT NOTE: FOR SAFE AND
Contractor:
Submitted By:
Date:
1
” 27
⁄
4
1
” 43
⁄
4
1
” 25
⁄
8
1
” 41
⁄
8
1
”
⁄
8
1
”
⁄
8
TS0067-2 REV 2.16