Surprisingly Bright Light Anywhere
Installation Instructions
READYBRIGHT
Power Outage Lights
Instant Li ght the Moment You Lose Power
TM
What you need to install:
• 1 Small Screwdriver
• Required Batteries
Quick Start Guide
1. Insert
fresh
batteries
into lights.
MB220 Power Outage
Controller/Flashlight
Includ ed Per Light:
1 Controll er
1 Recharg eable 3.6V NiMH Ba ttery
2. Plug
Power Outage
Controller into
an active wall
outlet.
3. Controller
immediately
detects power
outage and
lights up.
1. Loosen the screw and remove the batter y door
on the MB220.
2. If you are setting up zones set dip switches to
match the other lights you want to control.
4. Controller
sends wireless
signal to other
ReadyBright
lights in home.
5. All Ready
Bright lights
within 70 feet
of controller
will activate.
Tips/Features
Auto Shut-o feature when you’re not home: If a power outage
occurs, all lights will activate and then blink at 29 minutes. All lights
will turn o automatically after 30 minutes. To keep lights on continuously for up to 40 hours, simply unplug MB220 from outlet or
press the ON button to override auto shut-o feature.
RF/Remote Control: MB220 can also turn other lights on remotely
at any time by pressing the ON button. If activated via remote
control, lights will stay on continuously until they are shut o with
the OFF button.
Setting Up Zones: Program specic lights to activate with a
specic controller, creating dierent zones through out your home.
Set dip switches inside each unit to match the dip switch setting of
the MB220 you’d like it to be controlled by.
Low Battery Indicator Light: A red light near the LED turns on
when batteries need to be replaced.
3. Plug battery into
ashlight with red wire
on the lef t and close
batter y lid. Secure
screw.
4. Plug into an outlet near
the center of your home.
Do not use an outlet
controlled by a switch or
an extension cord.
5. Mount the other
lights in the center of
your home. Be sure
they are within 70 ft of
the Detector.
MB785 Power Outage
Stair Light
Includ ed Per Light:
1 Stair Ligh t
1 Mountin g Bracket
2 Screws & 2 An chors
1 Adhesive Strip
*Note: MB220 R equired to ac tivate this unit
1. Remove mounting
bracket from back of
light.
2. Remove battery door
by removing 2 thumb
screws show above.
3. Insert 4 new Alkaline AA Batteries, with
correct polarity/position.
4. Do not mix old & new batteries.
5. If you are set ting up zones set dip
switches to match the MB220 you want it
controlled by.
6. Replace battery lid, secure with screws.
MB985 Power Outage
Ceiling Light
Includ ed Per Light:
1 Ceiling Li ght
1 Mountin g Bracket
2 Screws & 2 An chors
*Note: MB220 R equired to ac tivate th is unit
*Warning:
RISK OF ELECTRICAL SHOC K. For ad ult use o nly. This p roduc t is a light that us es 120V AC
power. This produ ct is not a toy and sho uld not be stored o r used i n locat ions ac cess ible to
children. For s afety, plug into exp osed wa ll outl et wher e device is venti lated and cann ot con-
tact be d coverings or other materials that ma y prese nt a re ha zard. Do not us e with ex tensi on
cords.
Protecting against power surges: To protect thi s product fro m lightning, storms an d power
outag es, we strongly recom mend it i s plugged into a s urge protecto r in order to redu ce the risk
of damage.
* Visit our website to view installation video.
* 1 year limited warranty. See enclosed card for details.
32333 Au rora Rd . Suite 100 S olon, O H 44139
877.298.9082 www.mrbeams.com
1. Remove mounting bracket
from back of light.
2. Remove back plate of light
by removing thumbscrew and
twisting counter-clockwise.
3 Insert 4 new Alkaline C batteries.
4. Do not mix old and new bat teries.
5. If you are set ting up zones set
dip switch to match the MB220 you
want it controlled by.
7. Mount Bracket to wall with double sided
tape, holding for 10 seconds or install with
2 small screws.
Note: This is a strong adhesive that may
cause damage to mounting surface. Please
consider your location before mounting.
6. To close, align tab with
notch, rotate back plate
clockwise until thumb screw
holes match.
7. Insert thumb screw and
tighten.
Battery Caution:
1) Do not mix ol d and new b atter ies
2) Do not mix Alkaline, Sta ndar d (Carb on-Zinc) or Rech argeable (N ickel Ca dmium) o r (Nicke l
Metal Hydride) batteries
3) Do not di spose of batte ries i n re
4)Batteries shoul d be recyc led or dispos ed of as pe r state a nd local guid eline s
**Th is devi ce comp lies wi th par t 15 of the FCC Ru les. Op eration is su bject to do the fol lowing
conditions:
1) This devi ce may not c ause harmfu l inter ference
2) This device must acce pt any inte rfe rence r eceived, inc ludin g inter ference that m ay caus e
undesired operation.
8. The word TOP should always face you.
If mounting to a wall, position so TOP is at
the highest point.
9. Drive 2 screws (included) through holes
of mounting bracket. To attach twist
clockwise until it stops. Always check
attachment that light is secure for safety.
8. Slide light onto mounting
bracket attached to wall.