MOTOROLA and the Stylized M Logo are registered in the US Patent & Trademark Office. Symbol is a registered
trademark of Symbol Technologies, Inc. All other product or service names are the property of their respective owners.
This guide provides information about using the following Motorola switches and version numbers:
• WS5100 3.3
• RFS6000 3.3
• RFS7000 1.3
About This Guide
NOTE: Screens and windows pictured in this guide are samples and can differ from actual
screens.
Documentation Set
The documentation set for the Motorola RF Series Switches is partitioned into the following guides to
provide information for specific user needs.
• Installation Guides - Each switch has a unique Installation Guide which describes the basic hardware
setup and configuration required to transition to more advanced configuration of the switches.
• Motorola RFS Series Wireless LAN Switches WiNG System Reference - Describes configuration
of the Motorola RF Switches using the Web UI.
• Motorola RFS Series Wireless LAN Switches WiNG CLI Reference - Describes the Command Line
Interface (CLI) and Management Information Base (MIB) commands used to configure the Motorola RF
Switches.
• RF Management Software Users Guide - Describes how to use Motorola RFMS to set up and monitor
your switch in respect to areas of good RF throughput and defined physical barriers.
Document Conventions
The following conventions are used in this document to draw your attention to important information:
NOTE: Indicate tips or special requirements.
SWITCH NOTE: Indicates caveats unique to a WS5100, RFS6000 or RFS7000 model
switch.
Page 10
viii Motorola RF Switch System Reference
CAUTION: Indicates conditions that can cause equipment damage or data loss.
!
WARNING! Indicates a condition or procedure that could result in personal
injury or equipment damage.
Notational Conventions
The following additional notational conventions are used in this document:
• Italics are used to highlight the following:
• Chapters and sections in this and related documents
• Dialog box, window and screen names
• Drop-down list and list box names
• Check box and radio button names
• Icons on a screen.
• GUI text is used to highlight the following:
• Screen names
• Menu items
• Button names on a screen.
• bullets (•) indicate:
• Action items
• Lists of alternatives
• Lists of required steps that are not necessarily sequential
• Sequential lists (e.g., those that describe step-by-step procedures) appear as numbered lists.
Page 11
Overview
A Motorola RF Switch is a centralized management solution for wireless networking. It connects to
non-legacy Access Ports through Layer 2 or Layer 3 (Layer 2 is preferable, if the situation allows it).
Access ports function as radio antennas for data traffic management and routing. System configuration and
intelligence for the wireless network resides with the switch. The switch uses Access Ports to bridge data
to and from wireless devices. The wireless switch applies appropriate policies to data packets before
forwarding them to their destination.
All data packets to and from wireless devices are processed by the switch, where appropriate policies are
applied before they are decapsulated and sent to their destination.
Access port configuration is managed by the switch through a Web UI Graphical User Interface (GUI), SNMP
or the switch Command Line Interface (CLI).
SWITCH NOTE: The discussion of the switch GUI within this guide is presented
generically, making it equally relevant to the WS5100, RFS6000 and RFS7000 switch
platforms. However, some subtle differences do exist amongst these baselines. These
differences are noted within the specific GUI elements impacted. When these differences
are noted, the options available to each switch baseline are described in detail.
Page 12
1-2 Motorola RF Switch Systen Reference
1.1 Hardware Overview
The WS5100, RFS6000 and RFS7000 are rack-mountable devices that manage all inbound and outbound
traffic on the wireless network. They provide security, network service and system management
applications.
Unlike traditional wireless infrastructure devices that reside at the edge of a network, the switch uses
centralized, policy-based management to apply sets of rules or actions to all devices on the wireless
network. The switch collects management “intelligence” from individual Access Ports/Points and moves the
collected information to the centralized switch.
Access ports (APs) are 48V Power-over-Ethernet devices connected to the switch by an Ethernet cable. An
Access Port receives 802.11x data from MUs and forwards the data to the switch which applies the
appropriate policies and routes the packets to their destinations.
Access ports do not have software or firmware upon initial receipt from the factory. When the Access Port
is first powered on and cleared for the network, the switch initializes the Access Port and installs a small
firmware file automatically. Therefore, installation and firmware upgrades are automatic and transparent.
1.1.1 Physical Specifications
The physical dimensions and operating parameters of the WS5100 include:
Width42.9 cm (16.89 in)
Height4.39 cm (1.73 in)
Depth40.46 cm (15.93 in)
Weight6.25 kg (13.75 lbs)
Operating Temperature10°C - 35°C (50°F - 95°F)
Operating Humidity5% - 85% RH, non-condensing
The physical dimensions and operating parameters of the RFS6000 include:
Width440mm (17.32 in)
Height44.45mm (1.75 in)
Depth390.8mm (15.38 in)
Weight6.35 Kg (14 lbs)
Operating Temperature0°C - 40°C (32°F - 104°F)
Operating Humidity5% - 85% RH, non-condensing
The physical dimensions and operating parameters of the RFS7000 include:
Width440mm (17.32 in)
Height44.45mm (1.75 in)
Depth390.8mm (15.38 in)
Weight6.12 Kg (13.5 lbs)
Page 13
Overview 1-3
Operating Temperature0°C - 40°C (32°F - 104°F)
Operating Humidity5% - 85% RH, non-condensing
A power cord is not supplied with a WS5100, RFS6000 or RFS7000 model switch. Use only a correctly rated
power cord certified for the country of operation
.
Page 14
1-4 Motorola RF Switch Systen Reference
1.1.1.1 Power Protection
To best protect the switch from unexpected power surges or other power-related problems, ensure the
switch installation meets the following guidelines:
• If possible, use a dedicated circuit to protect data processing equipment. Commercial electrical
contractors are familiar with wiring for data processing equipment and can help with the load balancing
of dedicated circuits.
• Install surge protection. Use a surge protection device between the electricity source and the switch.
• Install an Uninterruptible Power Supply (UPS). A UPS provides continuous power during a power outage.
Some UPS devices have integral surge protection. UPS equipment requires periodic maintenance to
ensure reliability.
1.1.1.2 Cabling Requirements
A minimum of one category 6 Ethernet cables (not supplied) are required to connect the switch to the LAN
and WLAN. The cable(s) are used with the Ethernet ports on the front panel of the switch.
SWITCH NOTE: On an RFS6000 and RFS7000, Motorola recommends connecting via the
Management Ethernet (ME) interface to better ensure secure and easier management.
The ME interface is connected to the management VLAN, and is therefore separate from
production VLANs.
SWITCH NOTE: On the RFS6000 the Uplink (UP) port is the preferred method of
connecting the switch to the network. The Uplink port has its own dedicated 1Gbps
connection which is unaffected by internal traffic across the GE ports.
The console cable included with the switch connects the switch to a computer running a serial terminal
emulator program to access the switch’s Command Line Interface (CLI) for initial configuration. An initial
configuration is described within the Installation Guide shipped with each switch.
1.2 Software Overview
The switch includes a robust set of features. The features are listed and described in the following sections:
• Infrastructure Features
• Wireless Switching
• Wired Switching
• Management Features
• Security Features
• Supported Access Ports/Points
NOTE: The Motorola RF Management Software is a recommended utility to plan the
deployment of the switch and view its configuration once operational in the field.
Motorola RFMS can help optimize the positioning and configuration of a switch in respect
to a WLAN’s MU throughput requirements and can help detect rogue devices. For more
information, refer to the Motorola Web site.
1.2.1 Infrastructure Features
The switch includes the following Infrastructure features:
Page 15
• Installation Feature
• Licensing Support
• Configuration Management
• Diagnostics
• Serviceability
• Tracing / Logging
• Process Monitor
• Hardware Abstraction Layer and Drivers
• Redundancy
• Secure Network Time Protocol (SNTP)
• Password Recovery
1.2.1.1 Installation Feature
The upgrade/downgrade of the switch can be performed at boot time using one of the following methods:
•Web UI
Overview 1-5
•DHCP
•CLI
•SNMP
• Patches
The switch has sufficient non-volatile memory to store two firmware images. Having a second firmware
image provides a backup in case of failure of the primary image. It also allows for testing of new firmware
on a switch with the ability to easily revert to a previous image.
1.2.1.2 Licensing Support
The following licensing information is utilized when upgrading the switch
• The maximum numbers of AP licenses a switch can adopt is dependant on the number purchased
1.2.1.3 Configuration Management
The switch supports the redundant storage of configuration files to protect against corruption during a write
operation and ensure (at any given time) a valid configuration file exists. If writingthe configuration file fails,
it is rolled back and a pre-write file is used.
Text Based Configuration
The configuration is stored a in human readable format (as a set of CLI commands).
1.2.1.4 Diagnostics
The following diagnostics are available:
1. In-service Diagnostics – In-service diagnostics provide a range of automatic health monitoring features
ensuring both the system hardware and software are in working order. In-service-diagnostics
continuously monitor available physical characteristics (as detailed below) and issue log messages when
warning or error thresholds are reached. There are three types of in-service diagnostics:
Page 16
1-6 Motorola RF Switch Systen Reference
• Hardware – Ethernet ports, chip failures, system temperature via the temperature sensors provided
by the hardware, etc.
• Software – CPU load, memory usage, etc.
• Environmental – CPU and air temperature, fans speed, etc.
2. Out-of-service Diagnostics – Out-of-service diagnostics are a set of intrusive tests run from the user
interface. Out-of-service diagnostics cannot be run while the switch is in operation. Intrusive tests
include:
• Ethernet loopback tests
• RAM tests, Real Time Clock tests, etc.
3. Manufacturing Diagnostics – Manufacturing diagnostics are a set of diagnostics used by manufacturing
to inspect quality of hardware.
1.2.1.5 Serviceability
A special set of Service CLI commands are available to provide additional troubleshooting capabilities for
service personnel (access to Linux services, panic logs, etc.). Only authorized users or service personnel are
provided access to the Service CLI.
A built-in Packet Sniffer enables service personnel and users to capture incoming and outgoing packets in a
buffer.
The switch also collects statistics for RF activity, Ethernet port activity etc. RF statistics include roaming
stats, packet counters, octets tx/rx, signal, noise SNR, retry, and information for each MU.
1.2.1.6 Tracing / Logging
Log messages are well-defined and documented system messages with various destinations. They are
numbered and referenced by ID. Each severity level group, can be configured separately to go to either the
serial console, telnet interface, log file or remote syslog server.
Trace messages are more free-form and are used mainly by support personnel for tracking problems. They
are enabled or disabled via CLI commands. Trace messages can go to a log file, the serial console, or the
current tty.
Log and trace messages are interleaved in the same log file, so chronological order is preserved. Log and
trace messages from different processes are similarly interleaved in the same file for the same reason.
Log message format is similar to the format used by syslog messages (RFC 3164). Log messages include
message severity, source (facility), the time the message was generated and a textual message describing
the situation triggering the event. For more information on using the switch logging functionality, see
Configuring System Logging on page 8-7.
1.2.1.7 Process Monitor
The switch Process Monitor checks to ensure processes under its control are up and running. Each monitored
process sends periodic heartbeat messages. A process that is down (due to a software crash or stuck in an
endless loop) is detected when its heartbeat is not received. Such a process is terminated (if still running)
and restarted (if configured) by the Process Monitor.
Page 17
1.2.1.8 Hardware Abstraction Layer and Drivers
The Hardware Abstraction Layer (HAL) provides an abstraction library with an interface hiding hardware/
platform specific data. Drivers include platform specific components such as Ethernet, Flash Memory storage
and thermal sensors.
1.2.1.9 Redundancy
Using the switch redundancy, up to 12 switches can be configured in a redundancy group (and provide group
monitoring). In the event of a switch failure, an existing cluster member assumes control. Therefore, the
switch supported network is always up and running even if a switch fails or is removed for maintenance or
a software upgrade.
The following redundancy features are supported:
• Up to 12 switch redundancy members are supported in a single group. Each member is capable of
tracking statistics for the entire group in addition to their own.
• Each redundancy group is capable of supporting an Active/Active configuration responsible for group
load sharing.
• Members within the same redundancy group can be deployed across different subnets.
Overview 1-7
• APs are load balanced across members of the group.
• Licenses are aggregated across the group. When a new member joins the group, the new member can
leverage the Access Port adoption license(s) of existing members.
• Each member of the redundancy group (including the reporting switch) is capable of displaying cluster
performance statistics for all members in addition to their own.
• Centralized redundancy group management using the switch CLI.
For more information on configuring the switch for redundancy support, see
Configuring Switch Redundancy & Clustering on page 5-34.
1.2.1.10 Secure Network Time Protocol (SNTP)
Secure Network Time Protocol (SNTP) manages time and/or network clock synchronization within the switch
managed network. SNTP is a client/server implementation. The switch (a SNTP client) periodically
synchronizes its clock with a master clock (an NTP server). For example, the switch resets its clock to
07:04:59 upon reading a time of 07:04:59 from its designated NTP server. Time synchronization is
recommended for the switch’s network operations. The following holds true:
• The switch can be configured to provide NTP services to NTP clients.
• The switch can provide NTP support for user authentication.
• Secure Network Time Protocol (SNTP) clients can be configured to synchronize switch time with an
external NTP server.
For information on configuring the switch to support SNTP, see Configuring Secure NTP on page 5-24.
1.2.1.11 Password Recovery
The switch has a provision allowing it to restore its factory default configuration if your password is lost. In
doing so however the current configuration is erased, but can be restored assuming if has been exported to
an external location. For information on password recovery, see
Switch Password Recovery on page 2-2.
Page 18
1-8 Motorola RF Switch Systen Reference
1.2.2 Wireless Switching
The switch includes the following wireless switching features:
• Adaptive AP
• Physical Layer Features
• Rate Limiting
• Proxy-ARP
• HotSpot / IP Redirect
• IDM (Identity Driven Management)
• Voice Prioritization
• Self Healing
• Wireless Capacity
• AP and MU Load Balancing
• Wireless Roaming
• Power Save Polling
• QoS
• Wireless Layer 2 Switching
• Automatic Channel Selection
• WMM-Unscheduled APSD
• Multiple VLANs per WLAN
1.2.2.1 Adaptive AP
An adaptive AP (AAP) is an AP-5131 or AP-7131 Access Point adopted by a wireless switch. The management
of an AAP is conducted by the switch, once the Access Point connects to the switch and receives its AAP
configuration.
An AAP provides:
• local 802.11 traffic termination
• local encryption/decryption
• local traffic bridging
• tunneling of centralized traffic to the wireless switch
The connection between the AAP and the switch can be secured using IPSec depending on whether a secure
WAN link from a remote site to the central site already exists.
The switch can be discovered using one of the following mechanisms:
• DHCP
• Switch fully qualified domain name (FQDN)
• Static IP addresses
The benefits of an AAP deployment include:
Page 19
• Centralized Configuration Management & Compliance - Wireless configurations across distributed sites
can be centrally managed by the wireless switch or cluster.
• WAN Survivability - Local WLAN services at a remote sites are unaffected in the case of a WAN outage.
• Securely extend corporate WLAN's to stores for corporate visitors - Small home or office deployments
can utilize the feature set of a corporate WLAN from their remote location.
• Maintain local WLAN's for specific applications - WLANs created and supported locally can be
concurrently supported with your existing infrastructure.
For an overview of AAP and how it is configured and deployed using the switch and Access Point, see
B.1 Adaptive AP Overview.
1.2.2.2 Physical Layer Features
802.11a
• DFS Radar Avoidance – Dynamic Frequency Selection (DFS) is mandatory for WLAN equipment intended
to operate in the frequency bands 5150 MHz to 5350 MHz and 5470 MHz to 5725 MHz when in countries
of the EU.
The purpose of DFS is:
Overview 1-9
• Detect interference from other systems and avoid co-channeling with those systems (most notably
radar systems).
• Provide uniform spectrum loading across all devices.
This feature is enabled automatically when the country code indicates that DFS is required for at
least one of the frequency bands that are allowed in the country.
• TPC – Transmit Power Control (TPC) meets the regulatory requirement for maximum power and mitigation
for each channel. TPC functionality is enabled automatically for every AP that operates on the channel.
802.11bg
• Dual mode b/g protection – ERP builds on the payload data rates of 1 and 2 Mbit/s that use DSSS
modulation and builds on the payload data rates of 1, 2, 5.5, and 11 Mbit/s, that use DSSS, CCK, and
optional PBCC modulations. ERP provides additional payload data rates of 6, 9, 12, 18, 24, 36, 48, and 54
Mbit/s. The transmission and reception capability for 1, 2, 5.5, 11, 6, 12, and 24 Mbit/s data rates is
mandatory.
Two additional optional ERP-PBCC modulation modes with payload data rates of 22 and 33 Mbit/s are
defined. An ERP-PBCC station may implement 22 Mbit/s alone or 22 and 33 Mbit/s. An optional
modulation mode (known as DSSS-OFDM) is also incorporated with payload data rates of 6, 9, 12, 18,
24, 36, 48, and 54 Mbit/s.
• Short slot protection – The slot time is 20 µs, except an optional 9 µs slot time may be used when the
BSS consists of only ERP STAs capable of supporting this option. The optional 9 µs slot time should not
be used if the network has one or more non-ERP STAs associated. For IBSS, the Short Slot Time field is
set to 0, corresponding to a 20 µs slot time.
1.2.2.3 Rate Limiting
Rate Limiting limits the maximum rate sent to or received from the wireless network per mobile unit. It
prevents any single user from overwhelming the wireless network. It can also provide differential service for
service providers. The uplink and downlink rate limits are usually configured on the radius server using
Page 20
1-10 Motorola RF Switch Systen Reference
Motorola vendor specific attributes. The switch extracts the rate limits from radius server response. When
such attributes are not present, the global settings on the switch are then applied.
1.2.2.4 Proxy-ARP
Proxy ARP is provided for MU's whose IP address is known. The WLAN generates an ARP reply on behalf of
a MU (if the MU's IP address is known). The ARP reply contains the MAC address of the MU (not the MAC
address of switch). Thus, the MU does not awaken to send ARP replies (increasing MU battery life and
conserving wireless bandwidth).
If an MU goes into PSP without transmitting at least one packet, its Proxy ARP will not work.
1.2.2.5 HotSpot / IP Redirect
A hotspot is a Web page users are forced to visit before they are granted access to the Internet. With the
advent of Wi-Fi enabled client devices (such as laptops and PDAs) commercial hotspots are common and can
be found at many airports, hotels and coffee shops. The hotspot re-directs the user’s traffic on hotspot
enabled WLANs to a web page that requires them to authenticate before granting access to the WLAN. The
following is a typical sequence for hotspot access:
1. A visitor with a laptop requires hotspot access at a site.
2. A user ID/ Password and hotspot ESSID is issued by the site receptionist or IT staff.
3. The user connects their laptop to this ESSID.
4. The laptop receives its IP configuration via DHCP.
5. The user opens a Web browser and connects to their home page.
6. The switch re-directs them to the hotspot Web page for authentication.
7. The user enters their User ID/ Password.
8. A Radius server authenticates the user.
9. Upon successful authentication, the user is directed to a Welcome Page that lists (among other things)
an Acceptable Use Policy.
10.The user agrees to the usage terms and is granted access to the Internet. (or other network services).
To setup a hotspot, create a WLAN ESSID and select Hotspot authentication from the Authentication menu.
This is simply another way to authenticate a WLAN user, as it would be impractical to authenticate visitors
using 802.1x. For information on configuring a hotspot, see Configuring Hotspots on page 4-34.
1.2.2.6 IDM (Identity Driven Management)
Radius authentication is performed for all protocols using a Radius-based authentication scheme (such as
EAP). Identity driven management is provided using a Radius client. The following IDMs are supported:
• User based SSID authentication — Denies authentication to MUs if associated to a ESSID configured
differently by their Radius server.
•User based VLAN assignment — Allows the switch to extract VLAN information from the Radius server.
• User based QoS — Enables QoS for the MU based on settings within the Radius Server.
Page 21
1.2.2.7 Voice Prioritization
The switch has the capability of having its QoS policy configured to prioritize network traffic requirements
for associated MUs. Use QoS to enable voice prioritization for devices using voice as its transmission priority.
Voice prioritization allows you to assign priority to voice traffic over data traffic, and (if necessary) assign
legacy voice supported devices (non WMM supported voice devices) additional priority.
Currently voice support implies the following:
• Spectralink voice prioritization - Spectralink sends packets that allow the switch to identify these MU's
as voice MU's. Thereafter, any UDP packet sent by these MU's is prioritized ahead of data.
• Strict priority - The prioritization is strict.
• Multicast prioritization - Multicast frames that match a configured multicast mask bypass the PSP queue.
This features permits intercom mode operation without delay (even in the presence of PSP MU's).
For more information on configuring voice prioritization for a target WLAN, see
Configuring WMM on page 4-62.
1.2.2.8 Self Healing
Self Healing is the ability to dynamically adjust the RF network by modifying transmit power and/or
supported rates upon an AP failure.
Overview 1-11
In a typical RF network deployment, APs are configured for Transmit Power below their maximum level. This
allows the Tx Power to be increased when there is a need to increase coverage when an AP fails.
When an AP fails, the Tx Power/Supported rates of APs neighboring the failed AP are adjusted. The Tx power
is increased and/or Supported rates are decreased. When the failed AP becomes operational again,
Neighbor AP’s Tx Power/Supported rates are brought back to the levels before the self healing operation
changed them.
The switch detects an AP failure when:
• AP stops sending heartbeats.
• AP beacons are no longer being sent. This is determined when other detector APs are no longer hearing
beacons from a particular AP.
Configure 0 (Zero) or more APs to act as either:
• Detector APs — Detector APs scan all channels and send beacons to the switch which uses the
information for self-healing.
• Neighbor APs — When an AP fails, neighbor APs assist in self healing.
• Self Healing Actions — When an AP fails, actions are taken on the neighbor APs to do
self-healing.
Detector APs
Configure an AP in either – Data mode (the regular mode) or Detector mode.
In Detector mode, an AP scans all channels at a configurable rate and forwards received beacons the switch.
The switch uses the information to establish a receive signal strength baseline over a period of time and
initiates self-healing procedures (if necessary).
Neighbor Configuration
Neighbor detect is a mechanism allowing an AP to detect its neighbors as well as their signal strength. This
enables you to verify your installation and configure it for self-healing when an AP fails.
Page 22
1-12 Motorola RF Switch Systen Reference
Self Healing Actions
If AP1 detects AP2 and AP3 as its neighbors, you can assign failure actions to AP2 and AP3 whenever AP1
fails.
Assign up to four self healing actions:
1. No action
2. Decrease supported rates
3. Increase Tx power
4. Both 2 and 3.
You can specify the Detector AP (AP2 or AP3) to stop detecting and adopt the RF settings of the failed AP. For
more information on configuring self healing, see Configuring Self Healing on page 5-54.
1.2.2.9 Wireless Capacity
Wireless capacity specifies the maximum numbers of MUs, Access Ports and wireless networks usable by a
switch. Wireless capacity is largely independent of performance. Aggregate switch performance is divided
among the switch clients (MUs and Access Ports) to find the performance experienced by a given user. Each
switch platform is targeted at specific market segments, so the capacity of each platform is chosen
appropriately. Wireless switch capacity is measured by:
• The maximum number of WLANs per switch
• The maximum number of Access Ports adopted per switch
• The maximum number of MUs per switch
• The maximum number of MUs per Access Port.
The actual number of Access Ports adoptable by a switch is defined by the switch licenses or the total
licenses in the cluster in which this switch is a member.
1.2.2.10 AP and MU Load Balancing
Fine tune a network to evenly distribute data and/or processing across available resources. Refer to the
following:
• MU Balancing Across Multiple APs
• AP Balancing Across Multiple Switches
MU Balancing Across Multiple APs
Per the 802.11 standard, AP and MU association is a process conducted independently of the switch. 802.11
provides message elements used by the MU firmware to influence roaming decisions. The switch
implements the following MU load balancing techniques:
• 802.11e admission control — 1 byte: channel utilization % and 1 byte: MU count is sent in QBSS Load
Element in beacons to MU.
• Motorola load balancing element (proprietary) — 2 byte: MU Count are sent in beacon to MU.
Page 23
AP Balancing Across Multiple Switches
At adoption, the AP solicits and receives multiple adoption responses from the switches on the network.
These adoption responses contain preference and loading information the AP uses to select the optimum
switch to be adopted by. Use this mechanism to define which APs are adopted by which switches. By default,
the adoption algorithm generally distributes AP adoption evenly among the switches available.
NOTE: Port adoption per switch is determined by the number of licenses acquired.
For more information on Access Port adoption in a layer 3 environment, see Configuring Layer 3 Access Port
Adoption on page 4-128.
1.2.2.11 Wireless Roaming
The following types of wireless roaming are supported by the switch:
• Interswitch Layer 2 Roaming
• Interswitch Layer 3 Roaming
Overview 1-13
• Fast Roaming
• International Roaming
• MU Move Command
• Power Save Polling
Interswitch Layer 2 Roaming
An associated MU (connected to a switch) can roam to another Access Port connected to a different switch.
Both switches must be on the same Layer 2 domain. Authentication information is not shared between the
switches, nor are buffered packets on one switch transferred to the other. Pre-authentication between the
switch and MU allows faster roaming.
Interswitch Layer 3 Roaming
Interswitch Layer 3 roaming allows MUs to roam between switches which are not on the same LAN or IP
subnet without the MUs or the rest of the network noticing. This allows switches to be placed in different
locations on the network without having to extend the MU VLANs to every switch.
Fast Roaming
Using 802.11i can speed up the roaming process from one AP to another. Instead of doing a complete 802.1x
authentication each time a MU roams between APs, 802.11i allows a MU to re-use previous PMK
authentication credentials and perform a four-way handshake. This speeds up the roaming process. In
addition to reusing PMKs on previously visited APs, Opportunistic Key Caching allows multiple APs to share
PMKs amongst themselves. This allows an MU to roam to an AP it has not previously visited and reuse a
PMK from another AP to skip the 802.1x authentication.
International Roaming
The wireless switch supports international roaming per the 802.11d specification.
Page 24
1-14 Motorola RF Switch Systen Reference
MU Move Command
As a value added proprietary feature between Motorola infrastructure products and Motorola MUs, a move
command has been introduced. The move command permits an MU to roam between ports connected to the
same switch without the need to perform the full association and authentication defined by the 802.11
standard. The move command is a simple packet up/packet back exchange with the Access Port. Verification
of this feature is dependent on its implementation in one or more mobile units.
1.2.2.12 Power Save Polling
An MU uses Power Save Polling (PSP) to reduce power consumption. When an MU is in PSP mode, the switch
buffers its packets and delivers them using the DTIM interval. The PSP-Poll packet polls the AP for buffered
packets. The PSP null data frame is used by the MU to signal the current PSP state to the AP.
1.2.2.13 QoS
QoS provides a data traffic prioritization scheme. QoS reduces congestion from excessive traffic.
If there is enough bandwidth for all users and applications (unlikely because excessive bandwidth comes at
a very high cost), then applying QoS has very little value. QoS provides policy enforcement for mission-critical
applications and/or users that have critical bandwidth requirements when the switch’s bandwidth is shared
by different users and applications.
QoS helps ensure each WLAN on the switch receives a fair share of the overall bandwidth, either equally or
as per the proportion configured. Packets directed towards MUs are classified into categories such as
Management, Voice and Data. Packets within each category are processed based on the weights defined for
each WLAN.
The switch supports the following QoS mechanisms:
802.11e QoS
802.11e enables real-time audio and video streams to be assigned a higher priority over data traffic. The
switch supports the following 802.11e features:
•Basic WMM
• WMM Linked to 802.1p Priorities
• WMM Linked to DSCP Priorities
• Fully Configurable WMM
• Admission Control
• Unscheduled-APSD
• TSPEC Negotiation
• Block ACKQBSS Beacon Element
802.1p Support
802.1p is a standard for providing QoS in 802-based networks. 802.1p uses three bits to allow switches to
re-order packets based on priority level.
Voice QoS
When switch resources are shared between a Voice over IP (VoIP) conversation and a file transfer, bandwidth
is normally exploited by the file transfer, thus reducing the quality of the conversation or even causing it to
Page 25
Overview 1-15
disconnect. With QoS, a VoIP conversation (a real-time session), receives priority, maintaining a high level of
voice quality. Voice QoS ensures:
• Strict Priority
• Spectralink Prioritization
• VOIP Prioritization (IP ToS Field)
• Multicast Prioritization
Data QoS
The switch supports the following data QoS techniques:
• Egress Prioritization by WLAN
• Egress Prioritization by ACL
DCSCP to AC Mapping
The switch provides arbitrary mapping between Differentiated Services Code Point (DCSCP) values and
WMM Access Categories. This mapping can be set manually.
Page 26
1-16 Motorola RF Switch Systen Reference
1.2.2.14 Wireless Layer 2 Switching
The switch supports the following layer 2 wireless switching techniques:
•WLAN to VLAN
• MU User to VLAN
•WLAN to GRE
1.2.2.15 Automatic Channel Selection
Automatic channel selection works sequentially as follows:
1. When a new AP is adopted, it scans each channel. However, the switch does not forward traffic at this
time.
2. The switch then selects the least crowded channel based on the noise and traffic detected on each
channel.
3. The algorithm used is a simplified maximum entropy algorithm for each radio, where the signal strength
from adjoining AP's/MU's associated to adjoining AP's is minimized.
4. The algorithm ensures adjoining AP's are as far away from each other as possible (in terms of channel
assignment).
NOTE: Individual radios can be configured to perform automatic channel selection.
1.2.2.16 WMM-Unscheduled APSD
This feature is also known as WMM Power Save or WMM-UPSD (Unscheduled Power Save Delivery).
WMM-UPSD defines an unscheduled service period, which are contiguous periods of time during which the
switch is expected to be awake. If the switch establishes a downlink flow and specifies UPSD power
management, it requests (and the AP delivers) buffered frames associated with that flow during an
unscheduled service period. The switch initiates an unscheduled service period by transmitting a trigger
frame. A trigger frame is defined as a data frame (e.g. an uplink voice frame) associated with an uplink flow
with UPSD enabled. After the AP acknowledges the trigger frame, it transmits the frames in its UPSD power
save buffer addressed to the triggering switch.
UPSD is well suited to support bi-directional frame exchanges between a voice STA and its AP.
1.2.2.17 Multiple VLANs per WLAN
The switch permits the mapping of a WLAN to more than one VLAN. When a MU associates with a WLAN,
the MU is assigned a VLAN by means of load balance distribution. The VLAN is picked from a pool assigned
to the WLAN. The switch tracks the number of MUs per VLAN, and assigns the least used/loaded VLAN to
the MU. This number is tracked on a per-WLAN basis.
A broadcast key, unique to the VLAN, encrypts packets coming from the VLAN. If two or more MUs are on
two different VLANs, they both hear the broadcast packet, but only one can decrypt it. The switch provides
each MU a unique VLAN broadcast key as part of the WPA2 handshake or group key update message of a
WPA handshake.
Page 27
Overview 1-17
Limiting Users Per VLAN
Not all VLANs within a single WLAN must have the same DHCP pool size. Assign a user limit to each VLAN
to allow the mapping of different pool sizes.
Specify the VLAN user limit. This specifies the maximum number of MUs associated with a VLAN (for a
particular WLAN). When the maximum MU limit is reached, no more MUs can be assigned to that VLAN.
Packet Flows
There are four packet flows supported when the switch is configured to operate with multiple VLAN per
WLAN:
• Unicast From Mobile Unit – Frames are decrypted, converted from 802.11 to 802.3 and switched to the
wired side of the VLAN dynamically assigned to the mobile device. If the destination is another mobile
device on the wireless side, the frame is encrypted and switched over the air.
• Unicast To Mobile Unit – The frame is checked to ensure the VLAN is same as that assigned to the mobile
device. It is then converted to an 802.11 frame, encrypted, and sent over the air.
• Multicast/Broadcast From Mobile Unit – The frame is treated as a unicast frame from the MU, with the
exception that it is encrypted with the per-VLAN broadcast key and then transmitted over the air.
• Multicast/Broadcast from Wired Side – If the frame comes from a VLAN mapped to the WLAN, it’s
encrypted using a per-VLAN broadcast key and transmitted over the air. Only MUs on that VLAN have a
broadcast key that can decrypt this frame. Other MUs receive it, but discard it.
In general, when there are multiple VLANs mapped to the same WLAN, the broadcast buffer queue size
scales linearly to accommodate a potential increase in the broadcast packet stream.
Roaming within the Switch
When a MU is assigned to a VLAN, the switch registers the VLAN assignment in its credential cache. If the
MU roams, it is assigned back to its earlier assigned VLAN. The cache is flushed upon detected MU inactivity
or if the MU associates over a different WLAN (on the same switch).
Roaming across a Cluster
MUs roam amongst switch cluster members. The switch must ensure a VLAN remains unchanged as an MU
roams. This is accomplished by passing MU VLAN information across the cluster using the interface used by
a hotspot. It automatically passes the username/password across the credential caches of the member
switches. This ensures a VLAN MU association is maintained even while the MU roams amongst cluster
members.
Roaming across a Layer 3 Mobility Domain
When an MU roams amongst switches in different Layer 3 mobility domains, Layer 3 ensures traffic is
tunneled back to the correct VLAN (on the home switch).
Interaction with Radius Assigned VLANs
Multiple VLANs per WLAN can co-exist with VLANs assigned by a Radius server. Upon association, an MU
is assigned to a VLAN from a pool of available VLANs. When the Radius server assigns the user another
VLAN, MU traffic is forwarded to that VLAN.
When 802.1x is used, traffic from the MU is dropped until authentication is completed. None of the MU data
is switched onto the temporarily VLAN. A Radius assigned VLAN overrides the statically assigned VLAN.
If the Radius assigned VLAN is among the VLANs assigned to a WLAN, it is available for VLAN assignment
in the future. If the Radius assigned VLAN is not one of the VLANs assigned to a WLAN, it is not available
Page 28
1-18 Motorola RF Switch Systen Reference
for future VLAN assignment. To configure Multiple VLANs for a single WLAN, see Assigning Multiple VLANs
per WLAN on page 4-30.
1.2.3 Wired Switching
The switch includes the following wired switching features:
• DHCP Servers
• DHCP User Class Options
• DDNS
• VLAN Enhancements
• Interface Management
1.2.3.1 DHCP Servers
Dynamic Host Configuration Protocol (DHCP) allows hosts on an IP network to request and be assigned IP
addresses as well as discover information about the network to which they are attached. Each subnet may
be configured with its own address pool. Whenever a DHCP client requests an IP address, the DHCP server
assigns an IP address from that subnet’s address pool.
When a DHCP server allocates an address for a DHCP client, the client is assigned a lease, which expires
after an pre-determined interval. Before a lease expires, clients (to which leases are assigned) are expected
to renew them to continue to use the addresses. Once the lease expires, the client is no longer permitted to
use the leased IP address. For information on defining the switch DHCP configuration, see
DHCP Server Settings on page 5-3.
1.2.3.2 DHCP User Class Options
A DHCP Server groups clients based on defined user-class option values. Clients with a defined set of userclass values are segregated by class. The DHCP Server can associate multiple classes to each pool. Each
class in a pool is assigned an exclusive range of IP addresses.
DHCP clients are compared against classes. If the client matches one of the classes assigned to the pool, it
receives an IP address from the range assigned to the class. If the client doesn't match any of the classes in
the pool, it receives an IP address from a default pool range (if defined).
Multiple IP addresses for a single VLAN allow the configuration of multiple IP addresses, each belonging to
different subnet. Class configuration allows a DHCP client to obtain an address from the first pool to which
the class is assigned. For more information, see Configuring the DHCP User Class on page 5-19.
1.2.3.3 DDNS
Dynamic DNS (DDNS) keeps a domain name linked to a changing IP address. Typically, when a user connects
to a network, the user’s ISP assigns it an unused IP address from a pool of IP addresses. This address is only
valid for a short period. Dynamically assigning IP addresses increases the pool of assignable IP addresses.
DNS maintains a database to map a given name to an IP address used for communication on the Internet.
The dynamic assignment of IP addresses makes it necessary to update the DNS database to reflect the
current IP address for a given name. Dynamic DNS updates the DNS database to reflect the correct mapping
of a given name to an IP address.
1.2.3.4 VLAN Enhancements
The switch has incorporated the following VLAN enhancements:
Page 29
• Network interfaces operate in either trunk or access modes.
• A network interface in access mode can only send and receive untagged packets.
• A trunk port can now receive both tagged and untagged packets. Each ethernet port is assigned a native
VLAN.
• You can now configure a set of allowed VLANs on a trunk port. Packets received on this port that belong
to other VLANs are discarded.
1.2.3.5 Interface Management
The switch’s physical interfaces auto-negotiate speed and duplex. The switch also allows:
• Manual bandwidth configuration of a physical interface speed to 10/100/1000Mbps.
• Manual duplex configuration of a physical interface to Full Duplex or Half Duplex.
• Manual configuration of administrative shutdown of a physical interface.
1.2.4 Management Features
The switch supports the following management features:
Overview 1-19
• A secure, browser-based management console
•A Command Line Interface (CLI) accessible via the serial port or through Telnet or a Secure Shell (SSH)
application
• A CLI Service mode enabling the capture of system status information that can be sent to Motorola
personnel for use in problem resolution
• The support for Simple Network Management Protocol (SNMP) version 3 as well as SNMP version 2
• Upload and download of Access Port firmware and configuration files using TFTP, FTP, SFTP and HTTP.
• Transfer of firmware and configuration files using Compact Flash (RFS7000 only) or USB (RFS6000 and
RFS7000 platforms only)
• The graphing of wireless statistics
• A GUI dashboard summary of system status
• Multi switch management via MSP application
• Heat map support for RF deployment
• Secure guest access with specific permission intervals
• Switch discovery enabling users to discover each Motorola switch on the specified network.
Page 30
1-20 Motorola RF Switch Systen Reference
1.2.5 Security Features
Switch security can be classified into wireless security and wired security.
The switch includes the following wireless security features:
• Encryption and Authentication
• MU Authentication
• Secure Beacon
• MU to MU Disallow
• 802.1x Authentication
• WIPS
• Rogue AP Detection
The switch includes the following wired security features:
• ACLs
• Local Radius Server
• IPSec VPN
• NAT
• Certificate Management
1.2.5.1 Encryption and Authentication
The switch can implement the following encryption and authentication types:
• WEP
• WPA
• WPA2
• Keyguard-WEP
WEP
Wired Equivalent Privacy (WEP) is an encryption scheme used to secure wireless networks. WEP was
intended to provide comparable confidentiality to a traditional wired network, hence the name. WEP had
many serious weaknesses and hence was superseded by Wi-Fi Protected Access (WPA). Regardless, WEP
still provides a level of security that can deter casual snooping. For more information on configuring WEP for
a target WLAN, see Configuring WEP 64 on page 4-51 or Configuring WEP 128 / KeyGuard on page 4-52.
WEP uses passwords entered manually at both ends (Pre Shared Keys). Using the RC4 encryption algorithm,
WEP originally specified a 40-bit key, but was later boosted to 104 bits. Combined with a 24-bit initialization
vector, WEP is often touted as having a 128-bit key.
Page 31
Overview 1-21
WPA
WPA is designed for use with an 802.1X authentication server, which distributes different keys to each user.
However, it can also be used in a less secure pre-shared key (PSK) mode, where every user is given the same
passphrase.
WPA uses Temporal Key Integrity Protocol (TKIP), which dynamically changes keys as the system is used.
When combined with the much larger Initialization Vector, it defeats well-known key recovery attacks on
WEP. For information on configuring WPA for a WLAN, see Configuring WPA/WPA2 using TKIP and CCMP
on page 4-54.
WPA2
WPA2 uses a sophisticated key hierarchy that generates new encryption keys each time a MU associates
with an Access Point. Protocols including 802.1X, EAP and Radius are used for strong authentication. WPA2
also supports the TKIP and AES-CCMP encryption protocols. For information on configuring WPA for a WLAN,
see Configuring WPA/WPA2 using TKIP and CCMP on page 4-54.
Keyguard-WEP
KeyGuard is Motorola’s proprietary dynamic WEP solution. Motorola (upon hearing of the vulnerabilities of
WEP) developed a non standard method of rotating keys to prevent compromises. Basically, KeyGuard is TKIP
without the message integrity check. KeyGuard is proprietary to Motorola MUs only. For information on
configuring KeyGuard for a WLAN, see Configuring WEP 128 / KeyGuard on page 4-52.
1.2.5.2 MU Authentication
The switch uses the following authentication schemes for MU association:
• Kerberos
• 802.1x EAP
• MAC ACL
Refer to Editing the WLAN Configuration on page 4-25 for additional information.
Kerberos
Kerberos allows for mutual authentication and end-to-end encryption. All traffic is encrypted and security
keys are generated on a per-client basis. Keys are never shared or reused, and are automatically distributed
in a secure manner. For information on configuring Kerberos for a WLAN, see
Configuring Kerberos on page 4-33.
802.1x EAP
802.1x EAP is the most secure authentication mechanism for wireless networks and includes
EAP-TLS, EAP-TTLS and PEAP. The switch is a proxy for Radius packets. An MU does a full 802.11
authentication and association and begins transferring data frames. The switch realizes the MU needs to
authenticate with a Radius server and denies any traffic not Radius related. Once Radius completes its
authentication process, the MU is allowed to send other data traffic. You can use either an onboard Radius
server or internal Radius Server for authentication. For information on configuring 802.1x EAP for a WLAN,
see Configuring 802.1x EAP on page 4-32.
MAC ACL
The MAC ACL feature is basically a dynamic MAC ACL where MUs are allowed/denied access to the network
based on their configuration on the Radius server. The switch allows 802.11 authentication and association,
then checks with the Radius server to see if the MAC address is allowed on the network. The Radius packet
Page 32
1-22 Motorola RF Switch Systen Reference
uses the MAC address of the MU as both the username and password (this configuration is also expected
on the Radius server). MAC-Auth supports all encryption types, and (in case of 802.11i) the handshake is
completed before the Radius lookup begins. For information on configuring 802.1x EAP for a WLAN, see
Configuring MAC Authentication on page 4-43.
1.2.5.3 Secure Beacon
Devices in a wireless network use Service Set Identifiers (SSIDs) to communicate. An SSID is a text string
up to 32 bytes long. An AP in the network announces its status by using beacons. To avoid others from
accessing the network, the most basic security measure adopted is to change the default SSID to one not
easily recognizable, and disable the broadcast of the SSID.
The SSID is a code attached to all packets on a wireless network to identify each packet as part of that
network. All wireless devices attempting to communicate with each other must share the same SSID. Apart
from identifying each packet, the SSID also serves to uniquely identify a group of wireless network devices
used in a given service set.
1.2.5.4 MU to MU Disallow
Use MU to MU Disalllow to restrict MU to MU communication within a WLAN. The default is ‘no’, which
allows MUs to exchange packets with other MUs. It does not prevent MUs on other WLANs from sending
packets to this WLAN. You would have to enable MU to MU Disallow on the other WLAN. To define how MU
to MU traffic is permitted for a WLAN, see Editing the WLAN Configuration on page 4-25.
1.2.5.5 802.1x Authentication
802.1x Authentication cannot be disabled (its always enabled). A factory delivered out-of-the-box
AP300 supports 802.1x authentication using a default username and password. EAP-MD5 is used for 802.1x.
When you initially switch packets on an out-of-the-box AP300 port, it immediately attempts to authenticate
using 802.1x. Since 802.1x supports supplicant initiated authentication, the AP300 attempts to initiate the
authentication process.
On reset (all resets including power-up), the AP300 sends an EAPOL start message every time it sends a Hello
message (periodically every 1 second). The EAPOL start is the supplicant initiated attempt to become
authenticated.
If an appropriate response is received in response to the EAPOL start message, the AP300 attempts to
proceed with the authentication process to completion. Upon successful authentication, the AP300 transmits
the Hello message and the download proceeds the way as it does today.
If no response is received from the EAPOL start message, or if the authentication attempt is not successful,
the AP300 continues to transmit Hello messages followed by LoadMe messages. If a parent reply is received
in response to the Hello message, then downloading continue normally - without authentication. In this case,
you need not enable or disable the port authentication.
802.1x authentication is conducted:
• At power up
• On an AP300 operator initiated reset (such as pulling Ethernet cable)
• When the switch administrator initiates a reset of the AP300.
• When re-authentication is initiated by the Authenticator (say the switch in between)
Page 33
Change Username/Password after AP Adoption
Once the AP300 is adopted using 802.1x authentication (say default username/password) OR using a nonsecure access method (hub or switch without 802.1x enabled), use the CLI/SNMP/UI to reconfigure the
username/password combination.
Reset Username/Password to Factory Defaults
To restore the AP300 username/password to factory defaults, adopt the AP300 using a non-secure access
method (a hub or switch without 802.1x enabled), then reconfigure the username/password combination.
The Access Port does not make use of any parameters (such as MAC based authentication, VLAN based etc.)
configured on Radius Server.
1.2.5.6 WIPS
The Motorola Wireless Intrusion Protection Software (WIPS) monitors for any presence of unauthorized
rogue Access Points. Unauthorized attempts to access the WLAN is generally accompanied by anomalous
behavior as intruding MUs try to find network vulnerabilities. Basic forms of this behavior can be monitored
and reported without needing a dedicated WIPS. When the parameters exceed a configurable threshold, the
switch generates an SNMP trap and reports the result via the management interfaces. Basic WIPS
functionality does not require monitoring APs and does not perform off-channel scanning.
Overview 1-23
NOTE: When converting an AP300 to an Intrusion Detection Sensor, the conversion
requires approximately 60 seconds.
NOTE: When using an AP-5131for use with WIPS and as a sensor you must first configure
the WIPS server IP Addresses before converting the AP-5131 to a sensor.
1.2.5.7 Rogue AP Detection
The switch supports the following techniques for rogue AP detection:
• RF scan by Access Port on all channels
• SNMP Trap on discovery
• Authorized AP Lists
• Rogue AP Report
• Motorola RFMS Support
NOTE: The Motorola RF Management Software is recommended to plan the deployment
of the switch. Motorola RFMS can help optimize the positioning and configuration of a
switch in respect to a WLAN’s MU throughput requirements and can help detect rogue
devices. For more information, refer to the Motorola Web site.
Page 34
1-24 Motorola RF Switch Systen Reference
RF scan by Access Port on one channel
This process requires an Access Port to assist in Rogue AP detection. It functions as follows:
• The switch sends a new configuration message to the adopted AP informing it to detect Rogue APs.
• The Access Port listens for beacons on its present channel.
• It passes the beacons to the switch as it receives them without any modification.
• The switch processes these beacon messages to generate the list of APs
This process of detecting a Rogue AP is non-disruptive and none of the MUs are disassociated during this
process. The Access Port will only scan on its present channel. An AP300 provides this support.
By choosing this option for detection, all capable Access Ports will be polled for getting the information.
RF scan by Access Port on all channels
The process used to scan for Rogue APs on all available channels functions as follows:
• The switch sends a configuration message (with the ACS bit set and channel dwell time) to the Access
Port.
• An Access Port starts scanning each channel and passes the beacons it hears on each channel to the
switch.
• An Access Port resets itself after scanning all channels.
• An switch then processes this information
SNMP Trap on discovery
An SNMP trap is sent for each detected and Rogue AP. Rogue APs are only detected, and notification is
provided via a SNMP trap.
NOTE: Wired side scanning for Rogue APs using WNMP is not supported. Similarly,
Radius lookup for approved AP is not provided.
Authorized AP Lists
Configure a list of authorized Access Ports based on their MAC addresses. The switch evaluates the APs
against the configured authorized list after obtaining Rogue AP information from one of the 2 mechanisms
as mentioned in Rogue AP Detection on page 1-23.
Rogue AP Report
After determining which are authorized APs and which are Rogue, the switch prepares a report.
Motorola RFMS Support
With this most recent switch firmware release, the switch can provide rogue device detection data to the
Motorola RF Management software application (or Motorola RFMS). Motorola RFMS uses this data to refine
the position and display the rogue on a site map representative of the physical dimensions of the actual radio
coverage area of the switch. This is of great assistance in the quick identification and removal of
unauthorized devices.
1.2.5.8 ACLs
ACLs control access to the network through a set of rules. Each rule specifies an action taken when a packet
matches a set of rules. If the action is deny, the packet is dropped. If the action is permit, the packet is
Page 35
allowed. If the action is to mark, the packet is tagged for priority. The switch supports the following types of
ACLs:
• IP Standard ACLs
• IP Extended ACLs
• MAC Extended ACLs
• Wireless LAN ACLs
For information on creating an ACL, see Configuring Firewalls and Access Control Lists on page 6-19.
1.2.5.9 Local Radius Server
Radius is a common authentication protocol utilized by the 802.1x wireless security standard. Radius
improves the WEP encryption key standard, in conjunction with other security methods such as EAP-PEAP.
The switch has one onboard Radius server. For information on configuring the switch’s resident Radius
Server, see Configuring the Radius Server on page 6-70.
1.2.5.10 IPSec VPN
IP Sec is a security protocol providing authentication and encryption over the Internet. Unlike SSL (which
provides services at layer 4 and secures two applications), IPsec works at Layer 3 and secures the network.
Also unlike SSL (which is typically built into the Web browser), IPsec requires a client installation. IPsec can
access both Web and non-Web applications, whereas SSL requires workarounds for non-Web access such
as file sharing and backup.
Overview 1-25
A VPN is used to provide secure access between two subnets separated by an unsecured network. There are
two types of VPNs:
• Site-Site VPN — For example, a company branching office traffic to another branch office traffic with
an unsecured link between the two locations.
• Remote VPN — Provides remote user ability to access company resources from outside the company
premises.
The switch supports:
• IPSec termination for site to site
• IPSec termination for remote access
• IPSec traversal of firewall filtering
• IPSec traversal of NAT
• IPSec/L2TP (client to switch)
Page 36
1-26 Motorola RF Switch Systen Reference
1.2.5.11 NAT
Network Address Translation (NAT) is supported for packets routed by the switch. The following types of NAT
are supported:
• Port NAT– Port NAT (also known as NAPT) entails multiple local addresses are mapped to single global
address and a dynamic port number. The user is not required to configure any NAT IP address. Instead IP
address of the public interface of the switch is used to NAT packets going out from private network and
vice versa for packets entering private network.
• Static NAT– Static NAT is similar to Port NAT with the only difference being that it allows the user to
configure a source NAT IP address and/or destination NAT IP address to which all the packets will be
NATted to. The source NAT IP address is used when hosts on a private network are trying to access a
host on a public network. A destination NAT IP address can be used for public hosts to talk to a host on
a private network.
1.2.5.12 Certificate Management
Certificate Management is used to provide a standardized procedure to:
• Generate a Server certificate request and upload the server certificate signed by certificate authority
(CA).
• Uploading of CA's root certificate
• Creating a self-signed certificate
Certificate management will be used by the applications HTTPS, VPN, HOTSPOT and Radius. For information
on configuring switch certificate management, see Creating Server Certificates on page 6-84.
1.2.5.13 NAC
Using Network Access Control (NAC), the switch hardware and software grants access to specific network
resources. NAC performs a user and MU authorization check for resources that do not have a NAC agent.
NAC verifies a MU’s compliance with the switch’s security policy. The switch supports only the EAP/802.1x
type of NAC. However, the switch also provides a mean to bypass NAC authentication for MU’s that do not
have NAC 802.1x support (printers, phones, PDAs etc.). For information on configuring NAC support, see
Configuring NAC Server Support on page 4-48.
1.2.6 Supported Access Ports/Points
A RF switch supports the adoption of the following Motorola Enterprise Access Ports and Access Points:
• AP100
• AP300
• AP-5131
• AP-7131
Page 37
Switch Web UI Access and Image Upgrades
The content of this chapter is segregated amongst the following:
• Accessing the Switch Web UI
• Switch Password Recovery
• Upgrading the Switch Image
• Auto Installation
• AP-4131 Access Point to Access Port Conversion
2.1 Accessing the Switch Web UI
2.1.1 Web UI Requirements
The switch Web UI is accessed using Internet Explorer version 5.5 (or later) and SUN JRE (Java Runtime
Environment) 1.5 (or later). Refer to the Sun Microsystems Web site for information on downloading JRE.
NOTE: To successfully access the switch Web UI through a firewall, UDP port 161 must
be open in order for the switch’s SNMP backend to function.
To prepare Internet Explorer to run the Web UI:
1. Open IE’s Tools > Internet Options panel and select the Advanced tab.
2. Uncheck the following checkboxes:
• Use HTTP 1.1
• Java console enabled (requires restart)
• Java logging enabled
• JIT compiler for virtual enabled (requires restart).
2.1.2 Connecting to the Switch Web UI
To display the Web UI, launch a Web browser on a computer with the capability of accessing the switch.
NOTE: Ensure you have HTTP connectivity to the switch, as HTTP is a required to launch
the switch Web UI from a browser.
Page 38
2-2 Motorola RF Switch System Reference
To display the switch Web UI:
1. Point the browser to the IP address assigned to the wired Ethernet port (port 2). Specify a secure
connection using the https:// protocol.
The switch login screen displays:
2. Enter the Username admin, and Password superuser. Both are case-sensitive. Click the Login button.
NOTE: If using HTTP to login into the switch, you may encounter a Warning screen if a
self-signed certificate has not been created and implemented for the switch. This warning
screen will continue to display on future login attempts until a self-signed certificate is
implemented. Motorola recommends only using the default certificate for the first few
login attempts until a self-signed certificate can be generated.
NOTE: If your password is lost, there is a means to access the switch, but you are forced
to revert the switch back to its factory default settings and lose your existing
configuration (unless saved to a secure location). Consequently, Motorola recommends
keeping the password in a secure location so it can be retrieved. For information on
password recovery, see Switch Password Recovery on page 2-2.
Once the Web UI is accessed, the Switch main menu item displays a configuration tab with high-level
switch information. Click the Show Dashboard button to display an overall indicator of switch health.
Once the switch is fully configured, the dashboard is the central display for the user to view the version
of firmware running on the switch, quickly assess the last 5 alarms generated by the switch, view the
status of the switch’s Ethernet connections and view switch CPU and memory utilization statistics.
NOTE: The chapters within this System Reference Guide are arranged to be
complimentary with the main menu items in the menu tree of the switch Web UI. Refer to
this content to configure switch network addressing, security and diagnostics as required.
Page 39
Switch Web UI Access and Image Upgrades
2.2 Switch Password Recovery
The switch has a means of restoring its password to its default value. Doing so also reverts the switch’s
security, radio and power management configuration to their default settings. Only an installation
professional should reset the switch password and promptly define a new restrictive password.
To contact Motorola Support in the event of a password reset requirement, go to
http://www.symbol.com/contactsupport
CAUTION: Only a qualified installation professional should set or restore the switch’s
radio and power management configuration in the event of a password reset.
.
!
Page 40
2-4 Motorola RF Switch System Reference
2.3 Upgrading the Switch Image
The switch ships with a factory installed firmware image with the full feature functionality described in this
System Reference Guide. However, Motorola periodically releases switch firmware that includes
enhancements or resolutions to known issues. Verify your current switch firmware version with the latest
version available from the Motorola Web site before determining if your system requires an upgrade.
2.4 Auto Installation
The switch auto install function can be configured manually or using a DHCP server. When configuring auto
installation using DHCP, the server requires the definition of a vendor class and four sub-options under option
43 namely:
• Option 186 - defines the tftp/ftp server and ftp username, password information
• Option 187 - defines the firmware path and file name
• Option 188 - defines the config path and file name
• Option 190 - defines the cluster config path and file name.
The individual features (config, cluster-config and image) can be enabled separately using the CLI, SNMP or
Web UI. If a feature is disabled, it is skipped when auto install is triggered.
For manual configuration (where the URLs for the configuration and image files are not supplied by DHCP),
the URLs can be specified using the CLI, SNMP or Applet. Use the CLI to define the expected firmware image
version. If the image version is not specified, the switch will derive it from the header of the firmware image
file.
Configuration files are tracked by their MD5 checksum. Configuration files are tracked by their contents. If a
file is renamed its contents remain the same and the file will not be reloaded.
The requested image file version (if any) is checked against the current version before any attempt is made
to load it. If the requested version is the same as the running version, no action is taken. If the image file
version (embedded in the file header) does not match the expected version, no further action is taken. If the
version has not been specified, the image file header is compared to the local version. If they are the same,
no action is taken.
NOTE: Once the system has been operating for ten minutes, Auto Install is disabled,
though it may still be reconfigured. This is to prevent the system from attempting to reinstall each time a DHCP lease is renewed.
Configuring Auto Install via the CLI
There are three compulsory and four optional configuration parameters.
The compulsory parameters are:
• configuration upgrade enable
• cluster configuration upgrade enable
• image upgrade enable
Optional (only for the static case):
• configuration file URL
• cluster configuration file URL
Page 41
Switch Web UI Access and Image Upgrades
• image file URL
• expected image version
To set default to no, and the URLs and the version default to "" (blank):
RF Switch(config)#show autoinstall
feature enabled URL
config no --not-set-cluster cfg no --not-set-image no --not-set-expected image version --not-set--
Enables are set using the autoinstall <feature> command:
After this configuration update, any switch reboot with DHCP enabled on the RON port will trigger an auto
install, provided the DHCP Server is configured with appropriate options.
The "enables" are cleared using the no autoinstall <feature>
URLs and the version string are stored in the configuration file as text and can be cleared using an empty
pair of double quotes to denote the blank string. In the following example, define the three URLs and the
expected version of the image file, then enable all three features for the auto install.
Once again, for DHCP option based auto install the URLs is ignored and those passed by DHCP are not stored.
Whenever a string is blank it is shown as --not-set--.
Page 42
2-6 Motorola RF Switch System Reference
2.5 AP-4131 Access Point to Access Port Conversion
SWITCH NOTE: AP-4131 Access Point to Access Port Conversion is only available on
the WS5100 and RFS6000 platforms.
To convert an AP-4131 “fat” Access Point to a “thin” AP-4131 Access Port you need to load the port
conversion version firmware. Refer to the files available with you Motorola Web site download package.
To convert an AP-4131 Access Point
1. Verify a TFTP server is up and running and the firmware you are going to install is in the root directory of
the TFTP server.
2. Log in to the AP-4131 as Admin. The default password is Symbol.
3. Select the AP Installation main menu item.
4. From the IP Address field, enter a new IP address (if required) and select Save-[F1] to save the change.
If the IP address was changed, you will need to reset the AP for the change to be implemented.
Page 43
Switch Web UI Access and Image Upgrades
5. Reset the AP if you changed the AP's IP address, buy displaying the System Summary and selecting the
Reset AP option. If you reset the AP-4131 you will need to login as Admin again.
6. Select the Special Functions main menu item.
7. Select the Firmware Update Menu-[F3] menu item
8. Select the Alter Filename(s)/HELP URL/TFTP Server menu item.
a. Confirm that the Firmware File Name is correct, make changes as needed.
b. Enter the IP address of your TFTP server, select enter.
c. Select F1 to save your changes.
9. Select Firmware under the Use TFTP to update Access Point's option.
10.Select yes when asked to confirm.
11.The AP-4131 will now reset, download and install the desired firmware.
12.Once the firmware download is complete, connect the AP-4131 to the PoE switch and the RF Switch The
AP-4131 should adopt and operate as a “thin” Access Port.
Page 44
2-8 Motorola RF Switch System Reference
Page 45
Switch Information
This chapter describes the Switch main menu information used to configure the switch. This chapter consists
of the following sections:
• Viewing the Switch Interface
• Viewing Switch Port Information
• Viewing Switch Configurations
• Viewing Switch Firmware Information
• Switch File Management
• Configuring Automatic Updates
• Viewing the Switch Alarm Log
• Viewing Switch Licenses
• How to use the Filter Option
3.1 Viewing the Switch Interface
The Switch Configuration tab provides high-level system, switch name and address information accessible
from one location. Use this information to assess whether the current firmware version is the most recent
and if the number of licenses available is correct to support the number of radio devices deployed. The values
displayed within the screen can be defined in numerous additional locations throughout the switch applet.
NOTE: The Motorola RF Management Software is a recommended utility to plan the
deployment of the switch and view its interface statistics once operational in the field.
Motorola RFMS can help optimize the positioning and configuration of a switch (and its
associated radios) in respect to a WLAN’s MU throughput requirements and can help
detect rogue devices. For more information, refer to the Motorola Web site.
The switch screen displays two tabs supporting the following configuration activities:
• Setting the Switch Country Code
• Setting the Switch Country Code
• Viewing Switch Statistics
Page 46
3-2 Motorola RF Switch System Reference
NOTE: When the switch’s configuration is successfully updated (using the Web UI), the
effected screen is closed without informing the user their change was successful.
However, if an error were to occur, the error displays within the effected screen’s Status
field and the screen remains displayed. With file transfer operations, the transfer screen
remains open during the transfer and remains open upon completion (with status
displayed within the Status field).
3.1.1 Setting the Switch Country Code
When initially logging into the system, the switch requests that you enter the correct country code for your
region. If a country code is not configured, a warning message will display stating that an incorrect country
setting will lead to the illegal use of the switch. Consequently, selecting the correct country is extremely
important. Each country has its own regulatory restrictions concerning electromagnetic emissions (channel
range) and the maximum RF signal strength transmitted. To ensure compliance with national and local laws,
be sure to set the Country value correctly.
3.1.2 Viewing the Switch Configuration
To view a high-level display of the switch configuration:
1. Select Switch from the main menu tree.
2. Click the Configuration tab.
3. Refer the System field to view or define the following information:
Page 47
Switch Information 3-3
System NameDisplays the designated system name. Provide a system name serving as a
reminder of the user base the switch supports (engineering, retail, etc.).
LocationThe Location parameter serves as a reminder of where the switch can be found.
Define the System Name as a specific identifier of the switch’s location. Use the
System Name and Location parameters together to optionally define the switch
name by the radio coverage type it supports and physical location. For example,
“second floor engineering.”
ContactDisplays a Contact value for system administration and troubleshooting. This
name should be the network administrator responsible for switch operations.
UptimeDisplays the current operational time for the device name defined within the
System Name field. Uptime is the cumulative time since the switch was last
rebooted or lost power.
FirmwareDisplays the current firmware version running on the switch. This version should
be periodically compared to the most recent version available on the Motorola
Web site, as versions with increased functionality are periodically released.
AP LicensesDisplays the number of Access Port licenses currently available for the switch.
This value represents the maximum number of Access Ports the switch is licensed
to adopt.
Date (MM/DD/
YYYY)
TimeDisplays the time of day used by the switch.
Time ZoneUse the drop-down menu to specify the time zone used with the switch. Adjusting
CountryUse the drop-down menu to specify the correct country of operation. Selecting the
Displays the day, month and year currently used with the switch.
the time zone will in turn, cause an adjustment to the time displayed.
country incorrectly could render your switch as operating illegally.
4. Click the Restart button to reboot the switch. The switch itself does not include a hardware reset
feature.
CAUTION: When rebooting the switch, the Radius Server will also be restarted
regardless of its state before the reboot.
!
5. Click the Shutdown button to shutdown and power off the switch.
NOTE: On the WS5100 the shutdown command will completely power off the switch. On
the RFS6000 and RFS7000 the shutdown command will shutdown the switch but the fans
on the switch will remain on.
6. Click the Show Dashboard button to display a screen with important indicators of switch health and
status. For more information, see Switch Dashboard Details. Referencing the Details screen is
recommended before new configurations are employed that utilize increased switch bandwidth.
7. Click the Reset Password button to display a screen to reset the password.
Page 48
3-4 Motorola RF Switch System Reference
Enter the new password within the Password and Confirm Password fields and click OK.
NOTE: When entering a new password for the switch, please note that the password
must be a minimum of 8 characters long.
8. Click the Revert button to undo any changes. The Revert button must be clicked before hitting the Apply
button for any changes to be reverted.
9. Click the Apply button to save the updates (to the Time Zone or Country parameters specifically).
3.1.3 Switch Dashboard Details
Each Motorola RF Switch platform contains a dashboard whichrepresents a high-level graphical overview of
central switch processes and hardware. When logging into the switch, the dashboard should be the first
place you go to assess overall switch performance and any potential performance issues. .
Click the Show Dashboard button (within the Switch screen’s Configuration tab) to display the current
health of the switch
Page 49
3.1.3.1 WS5100 Switch Dashboard
Switch Information 3-5
The Dashboard screen displays the current health of the switch and is divided into fields representing the
following important diagnostics:
•Alarms
• Ports
• Environment
• CPU/Memory
• File Systems
Apart from the sections mentioned above, it also displays the following status:
Redundancy State
Firmware
Management IP
Displays the Redundancy State of the switch. The status can be either Enabled or
Disabled.
•Enabled - Defined a green state.
•Disabled - Defined by a yellow state.
Displays the Firmware version of the current software running on the wireless
switch.
Displays the Management IP address of the switch.
Access Ports
Displays the total number of Access Ports adopted by the switch.
Page 50
3-6 Motorola RF Switch System Reference
Mobile UnitsDisplays the total number of MUs associated with the switch.
Up TimeDisplays the actual switch uptime. The Uptime is the current operational time of
1. Refer to the Alarms field for details of all the unacknowledged alarms generated during the past 48
hours. The alarms are classified as:
• Critical — Denoted by a red indicator. These alarms warrant immediate attention.
• Major — Denoted by a yellow indicator. These alarms warrant attention.
• Others — Denoted by a blue indicator.
The alarms field also displays details (in a tabular format) of the 5 most recent unacknowledged critical/
major alarms raised during the past 48 hours. The table displays the following details:
the device defined within the System Name field. Uptime is the cumulative time
since the switch was last rebooted or lost power.
Severity
Last Occurrence
Message
# Occurrences
Displays the severity of the alarm. It can be either Critical or Major.
Displays the time when the alarm was reported.
Displays the message associated with the alarm.
Displays the number of times during the past 48 hours such an alarm was
generated.
2. Refer to the Ports field for link, speed and duplex status of each physical port on the switch’s front panel.
It displays the following details in a tabular format:
Name
Status
Speed
Duplex
Displays the name of the port, either—Ethernet1 or Ethernet 2
Displays the status of the port, either— Up or Down
Displays the speed at which the port transmits or receives data.
Displays the status of the port, either— Full Duplex or Unknown.
3. The Environment section displays the CPU temperature and switch fan speed. It displays the valid
threshold range set by the user.
4. The CPU/Memory section displays the free memory available with the RAM.
5. The File Systems section displays the free file system available for:
•flash
•nvram
• system
Page 51
3.1.3.2 RFS6000 Switch Dashboard
Switch Information 3-7
The Dashboard screen displays the current health of the switch and is divided into fields representing the
following important diagnostics:
•Alarms
• Ports
• Environment
• CPU/Memory
• File Systems
Apart from the sections mentioned above, it also displays the following status:
Redundancy State
Firmware
Management IP
Displays the Redundancy State of the switch. The status can be either Enabled or
Disabled.
•Enabled - Defined a green state.
•Disabled - Defined by a yellow state.
Displays the Firmware version of the current software running on the wireless
switch.
Displays the Management IP address of the switch.
Access Ports
Displays the total number of Access Ports adopted by the switch.
Page 52
3-8 Motorola RF Switch System Reference
Mobile UnitsDisplays the total number of MUs associated with the switch.
Up TimeDisplays the actual switch uptime. The Uptime is the current operational time of
1. Refer to the Alarms field for details of all the unacknowledged alarms generated during the past 48
hours. The alarms are classified as:
• Critical — Denoted by a red indicator. These alarms warrant immediate attention.
• Major — Denoted by a yellow indicator. These alarms warrant attention.
• Others — Denoted by a blue indicator.
The alarms field also displays details (in a tabular format) of the 5 most recent unacknowledged critical/
major alarms raised during the past 48 hours. The table displays the following details:
the device defined within the System Name field. Uptime is the cumulative time
since the switch was last rebooted or lost power.
Severity
Last Occurrence
Message
# Occurrences
Displays the severity of the alarm. It can be either Critical or Major.
Displays the time when the alarm was reported.
Displays the message associated with the alarm.
Displays the number of times during the past 48 hours such an alarm was
generated.
2. Refer to the Ports field for link, speed and duplex status of each physical port on the switch’s front panel.
It displays the following details in a tabular format:
Name
Status
Speed
Duplex
Displays the name of the port (ge1-8, me1 or up1)
Displays the status of the port, either— Up or Down
Displays the speed at which the port transmits or receives data.
Displays the status of the port, either— Full Duplex or Unknown.
3. The Environment section displays the CPU temperature. It displays the valid threshold range set by the
user.
4. The CPU/Memory section displays the free memory available with the RAM.
5. The File Systems section displays the free file system available for:
•flash
•nvram
• system
Page 53
3.1.3.3 RFS7000 Switch Dashboard
Switch Information 3-9
The Dashboard screen displays the current health of the switch and is divided into fields representing the
following important diagnostics:
•Alarms
• Ports
• Environment
• CPU/Memory
• File Systems
Apart from the sections mentioned above, it also displays the following status:
Redundancy State
Firmware
Management IP
Displays the Redundancy State of the switch. The status can be either Enabled or
Disabled.
•Enabled - Defined a green state.
•Disabled - Defined by a yellow state.
Displays the Firmware version of the current software running on the wireless
switch.
Displays the Management IP address of the switch.
Access Ports
Displays the total number of Access Ports adopted by the switch.
Page 54
3-10 Motorola RF Switch System Reference
Mobile UnitsDisplays the total number of MUs associated with the switch.
Up TimeDisplays the actual switch uptime. The Uptime is the current operational time of
the device defined within the System Name field. Uptime is the cumulative time
since the switch was last rebooted or lost power.
1. Refer to the Alarms field for details of all the unacknowledged alarms generated during the past 48
hours. The alarms are classified as:
• Critical — Denoted by a red indicator. These alarms warrant immediate attention.
• Major — Denoted by a yellow indicator. These alarms warrant attention.
• Others — Denoted by a blue indicator.
The alarms field also displays details (in a tabular format) of the 5 most recent unacknowledged critical/
major alarms raised during the past 48 hours. The table displays the following details:
Severity
Last Occurrence
Message
# Occurrences
Displays the severity of the alarm. It can be either Critical or Major.
Displays the time when the alarm was reported.
Displays the message associated with the alarm.
Displays the number of times during the past 48 hours such an alarm was
generated.
2. Refer to the Ports field for link, speed and duplex status of each physical port on the switch’s front panel.
It displays the following details in a tabular format:
Name
Status
Speed
Duplex
Displays the name of the port (ge1, ge2, ge3, ge4 and me1).
Displays the status of the port, either— Up or Down
Displays the speed at which the port transmits or receives data.
Displays the status of the port, either— Full Duplex or Unknown.
3. The Environment section displays the CPU temperature . It displays the valid threshold range set by the
user.
4. The CPU/Memory section displays the free memory available with the RAM.
5. The File Systems section displays the free file system available for:
•flash
•nvram
• system
Page 55
3.1.4 Viewing Switch Statistics
The Switch Statistics tab displays an overview of the recent network traffic and RF status for the switch.
To display the Switch Statistics tab:
1. Select Switch from the main menu tree.
2. Click the Switch Statistics tab at the top of the Switch screen.
Switch Information 3-11
3. Refer to the Switch Statistics field for the following read-only information about associated MUs:
Number of MUs
Associated
Number of APs
Adopted
Number of Radios
Adopted
Displays the total number of MUs currently associated to the switch.
Displays the total number of Access Ports currently adopted by the switch.
Displays the total number of radios currently adopted by the switch.
4. Refer to the Traffic field to assess network traffic for associated APs and radios:
Pkts per secondDisplays the packet transmission rate for received and transmitted packets over
last 30 seconds and 1 hour.
ThroughputDisplays the traffic throughput for packets received, packets transmitted and total
packets over last 30 seconds and 1 hour.
Page 56
3-12 Motorola RF Switch System Reference
Avg. Bit SpeedDisplays the average bit speed for the switch over last 30 seconds and 1 hour. Use
the average bit speed value to help determine overall network speeds and
troubleshoot network congestion.
% Non-unicast pktsDisplays the percentage of non-unicast packets seen (received & transmitted) by
the switch over last 30 seconds and 1 hour. Non-unicast traffic includes both
multicast and broadcast traffic.
Broadcasted, multicasted, and flooded packets are sent over the air at the slowest
rate on every radio in the WLAN and therefore have a much larger airtime
utilization than unicast packets a greater chance of causing collisions.
5. The RF Status section displays the following read-only RF radio signal information for associated APs
and radios:
Avg SignalDisplays the average signal strength for MUs associated with the switch over the
last 30 seconds and 1 hour. Typically, the higher the signal, the closer the MU.
Avg NoiseDisplays the average RF noise for all MUs associated with the selected WLAN.
MU noise for the last 30 seconds is displayed in black and the number in blue
represents MU noise for the last hour. If MU noise is excessive, consider moving
the MU closer to the Access Port, or in area with less conflicting network traffic.
Excessive noise may also be an indication of network interference.
Avg SNRDisplays the average Signal to Noise Ratio (SNR) for all MUs associated with the
switch. The Signal to Noise Ratio is an indication of overall RF performance on the
wireless network.
6. Refer to the Errors field for read-only packet error and loss information for associated Access Ports and
radios:
Average Number of
Retries
% Gave Up PktsDisplays the percentage of packets which the switch gave up on for all MUs
% Non-decryptable
Pkts
Displays the average number of retries for all MUs associated with the switch.
The number in black represents average retries for the last 30 seconds and the
number in blue represents average retries for the last hour.
If the Average Number of Retries starts increasing this indicates that MUs are not
getting a good link back to the AP.
associated with the switch. The number in black represents this statistic for the
last 30 seconds and the number in blue represents this statistic for the last hour.
If this field displays a non-zero number it indicates bad links causing packets to
the MUs
Displays the percentage of undecryptable packets for all MUs associated with the
switch. The number in black represents undecryptable pkts for the last 30 seconds
and the number in blue represents undecryptable pkts for the last hour.
If this field displays a non-zero number it can indicate outside intrusion into the
network or an MU using incorrect cryptography such as a a misconfigured static
key.
Page 57
3.2 Viewing Switch Port Information
The Port screen displays configuration, runtime status and statistics of the ports on the switch.
SWITCH NOTE: The ports available vary by switch platform.
WS5100: eth1, eth2
RFS6000: ge1, ge2, ge3, ge4, ge5, ge6, ge7, ge8, me1, up1
RFS7000: ge1, ge2, ge3, ge4, me1
The port types are defined as follows:
ETH#ETH ports are available on the WS5100 platform only. These ports are RJ-45
Ethernet ports supporting 10/100/1000Mbps.
GE#GE ports are available on the RFS6000 and RFS7000 platforms. GE ports on the
RFS6000 are RJ-45 which support 10/100/1000Mbps. GE ports on the RFS7000
can be RJ-45 or fiber ports which support 10/100/1000Mbps.
ME#ME ports are available on the RFS6000 and RFS7000 platforms. ME ports are out-
of-band management ports which can be used to manage the switch via CLI or
Web UI even when the other ports on the switch are unreachable.
UP#An UP port is available on the RFS6000 platform only. This port is used to connect
the RFS6000 to the backbone network. The UP port on the RFS6000 supports either
RJ-45 or fiber. The UP port is the preferred way to connect to the backbone as it
has a non-blocking 1gbps connection unlike the ge1-8 ports.
Switch Information 3-13
The Port screen contains three tabs supporting the following port assessment activities:
• Viewing the Port Configuration
• Viewing the Ports Runtime Status
• Reviewing Port Statistics
3.2.1 Viewing the Port Configuration
The Configuration tab displays the current configuration for the switch ports. Use the port configuration
information to determine whether an existing port configuration can be used as is or requires modification
for use within the switch managed network.
To view configuration details for the uplink and downlink ports:
1. Select Switch > Port from the main menu tree.
Page 58
3-14 Motorola RF Switch System Reference
2. Select the Configuration tab to display the following read-only information:
Name Displays the current port name. The port names available vary by switch.
MAC AddressDisplays the port’s MAC Address. This value is read-only, set at the factory and
cannot be modified.
Admin StatusDisplays whether the port is currently Up or Down.
SpeedDisplays the current speed of the data transmitted and received over the port.
DuplexDisplays the port as either half or full duplex.
SWITCH NOTE: On a RFS7000, the MAC address for the me1 port changes when the
switch firmware is updated to the 1.3 version. This addresses an issue where the switch
MAC address and ge1 interface shared the same MAC address in previous versions.
3. Select a port and click the Edit button to modify the port configuration. For additional information, see
Editing the Port Configuration.
3.2.1.1 Editing the Port Configuration
To modify the port configuration:
1. Select a port from the table displayed within the Configuration screen.
Page 59
Switch Information 3-15
2. Click the Edit button.
A Port Change Warning screen displays, stating any change to the port setting could disrupt access to
the switch. Communication errors may occur even if modifications made are successful.
3. Click the OK button to continue.
Optionally, select the Don’t show this message again for the rest of the session checkbox to disable
the pop-up.
4. Use the Edit screen to modify the following port configurations for the selected port.
Page 60
3-16 Motorola RF Switch System Reference
NameDisplays the read-only name assigned to the port.
SpeedSelect the speed at which the port can receive and transmit the data. Select from
the following range:
• 10 Mbps
• 100 Mbps
• 1000 Mbps
•Auto
DuplexModify the duplex status by selecting one of the following options:
•Half
•Full
•Auto
Channel GroupOptionally, set the Channel Group defined for the port. The switch bundles
individual Ethernet links (over the selected channel) into a single logical link that
provides bandwidth between the switch and another switch or host. The port
speed used is dependant on the Duplex value selected (full, half or auto). If a
segment within a channel fails, traffic previously carried over the failed link is
routed to the remaining segments within the channel. A trap is sent upon a failure
identifying the switch, channel and failed link.
DescriptionEnter a brief description for the port. The description should reflect the port’s
intended function to differentiate it from others with similar configurations.
Admin StatusEither Enable (activate) or Disable (shutdown) the admin status of the port.
MediumDisplays the current (read-only) connection medium used by this port.
Read-only details about the port’s cabling connection also display within the Edit screen. This
information should be used to determine the configuration defined for this port.
5. Click the OK button to commit the changes made to the port configurations.
6. Click Cancel to disregard any changes and revert back to the last saved configuration.
3.2.2 Viewing the Ports Runtime Status
The Runtime tab displays read-only runtime configuration for uplink and downlink ports.
To view the runtime configuration details of the uplink and downlink ports:
1. Select Switch > Port from the main menu tree.
Page 61
Switch Information 3-17
2. Select the Runtime tab to display the following read-only information:
Name Displays the port’s current name.
MAC AddressDisplays the port’s MAC Address. This value is read-only, set at the factory and
cannot be modified.
Oper StatusDisplays the link status of the port. The port status can be either Up or Down.
SpeedDisplays the current speed of the data transmitted and received over the port.
DuplexDisplays the port as either half duplex, full duplex or Unknown.
MTUDisplays the maximum transmission unit (MTU) setting configured on the port. The
MTU value represents the largest packet size that can be sent over a link. 10/100
Ethernet ports have a maximum MTU setting of 1500.
3.2.3 Reviewing Port Statistics
The Statistics tab displays read-only statistics for ethernet ports. Use this information to assess if
configuration changes are required to improve network performance.
To view the runtime configuration details of the switch ports:
1. Select Switch > Port from the main menu tree.
Page 62
3-18 Motorola RF Switch System Reference
2. Select the Statistics tab.
3. Refer to the Statistics tab to display the following read-only information:
NameDefines the port name.
Bytes InDisplays the total number of bytes received by the port.
Packets InDisplays the total number of packets received by the port.
Packets In DroppedDisplays the number of packets dropped by the port. If the number appears
excessive, a different port could be required.
Packets In ErrorDisplays the number of erroneous packets received by the port. If the number
appears excessive, try using a different port and see if the problem persists.
Bytes OutDisplays the total number of bytes transmitted by the port.
Packets OutDisplays the total number of packets transmitted by the port. A low value could be
an indication of a network problem.
Packets Out DroppedDisplays the total number of packets dropped during transmission. A high value
may be an indication of network throughput issues.
Packets Out ErrorDisplays the total number of erroneous transmitted packets.
4. Select a port and click on Details button to see the detailed port statistics. For more information, refer
to Detailed Port Statistics.
5. Select a port and click on Graph button to view the port statistics in a graphical format. For more
information, refer to Viewing the Port Statistics Graph.
3.2.3.1 Detailed Port Statistics
To view detailed statistics for a port:
1. Select a port from the table displayed within the Statistics screen.
Page 63
Switch Information 3-19
2. Click the Details button.
3. The Interface Statistics screen displays. This screen displays the following statistics for the selected
port:
NameDisplays the port name.
MAC AddressDisplays physical address information associated with the interface. This address
is read-only (hard-coded at the factory) and cannot be modified.
Input BytesDisplays the number of bytes received on the interface.
Input Unicast
Packets
Input NonUnicast
Packets
Input Total PacketsDisplays the total number of packets received on the interface.
Input Packets
Dropped
Input Packets ErrorDisplays the number of packets with errors received on the interface. Input Packet
Output BytesDisplays the number of bytes transmitted from the interface.
Output Unicast
Packets
Displays the number of unicast packets (packets directed towards the interface)
received on the interface.
Displays the number of NonUnicast Packets (Multicast and Broadcast Packets)
received on the interface.
Displays the number of received packets dropped by the interface by the input
Queue of the hardware unit /software module associated with the VLAN. Packets
are dropped when the input Queue is full or unable to processing incoming traffic.
Errors are input errors due to; no buffer space/ignored packets due to broadcast
storms, packets larger than maximum packet size, framing errors, input rate
exceeding the receiver's date handling rate or cyclic redundancy check errors. In
all of these cases, an error is reported and logged.
Displays the number of unicast packets (packets directed towards a single
destination address) transmitted from the interface.
Output NonUnicast
Packets
Output Total PacketsDisplays the total number of packets transmitted from the interface.
Displays the number of unicast packets transmitted from the interface.
Page 64
3-20 Motorola RF Switch System Reference
Output Packets
Dropped
Output Packets ErrorDisplays the number of transmitted packets with errors. Output Packet Errors are
Displays the number of transmitted packets dropped from the interface. Output
Packets Dropped are packets dropped when the output queue of the device
associated with the interface is saturated.
the sum of all the output packet errors, malformed packets and misaligned packets
received.
4. The Status is the current state of the requests made from the applet. Requests are any “SET/GET”
operation from the applet. The Status field displays error messages if something goes wrong in the
transaction between the applet and the switch.
5. Click on the Refresh button to refresh the port statistics.
6. Click on the Close button to exit out of the screen.
3.2.3.2 Viewing the Port Statistics Graph
The switch continuously collects data for port statistics. Even when the port statistics graph is closed, data
is still tallied. Periodically display the port statistics graph for assessing the latest information.
To view a detailed graph for a port:
1. Select a port from the table displayed in the Statistics screen.
2. Click the Graph button.
The Interface Statistics screen displays for the selected port. The screen provides the option to view
the following:
• Input Bytes
• Input Pkts Dropped
• Output Pkts Total
• Output Pkts Error
Page 65
• Input Pkts Total
• Input Pkts Error
• Output Pkts NUCast
• Input Pkts NUCast
• Output Bytes
• Output Pkts Dropped
3. Display any of the above by selecting the checkbox associated with it.
NOTE: You are not allowed to select (display) more than four parameters at any given
time.
4. Click on the Close button to exit out of the screen.
3.2.4 Power over Ethernet (PoE)
SWITCH NOTE: Power over Ethernet is ony supported on the RFS6000 switch. The
following information only applies to the RFS6000 switch.
Switch Information 3-21
The RFS6000 switch supports 802.3af Power over Ethernet (PoE) on each of its eight ge ports. The PoE screen
allows users to monitor the power consumption of the ports and configure power usage limits and priorities
for each of the ge ports.
To view the PoE configuration:
1. Select Switch > Port from the main menu tree.
Page 66
3-22 Motorola RF Switch System Reference
2. Select the PoE tab
SWITCH NOTE: The PoE screen is only available on the RF6000 switch. The WS5100
and RFS7000 switches do not have Power over Ethernet on any ports and will not display
the PoE tab.
The PoE Global Configuration section displays the following power information.
Power BudgetDisplays the total watts available for Power over Ethernet on the switch.
Power ConsumptionDisplays the total watts in use by Power over Ethernet on the switch.
Power Usage
Threshold for
Sending Trap
If you have modified the
Specify a percentage of power usage as the threshold before the switch sends an
SNMP trap. The percentage is a percentage of the total power budget of the
switch.
Power Usage Threshold for Sending Trap value, click the Apply button to save the
changes.
PortDisplays the port name for each of the PoE capable ports.
PoEDisplays the PoE status of each PoE capable port. Status will display Up when PoE
is available on the port and Down when PoE is unavailable on the port.
ClassDisplays the IEEE Power Classification for each port:
PriorityDisplays the priority mode for each of the PoE ports.
The priority options are:
Limit (watts)Displays the power limit in watts for each of the PoE ports. The maximum power
limit per port is 29.7 watts.
Power (watts)Displays each PoE ports power usage in watts.
Voltage (volts)Displays each PoE ports voltage usage in volts.
Current (mA)Displays each PoE ports current usage in miliAmps.
StatusDisplays the operational status for each PoE port. Ports can be either On or Off.
3.2.5 Editing Port PoE Settings
To modify the PoE settings for a port:
Switch Information 3-23
• Critical
•High
•Low
1. Select a port to edit from the table.
2. Click the Edit button.
The PoE Edit screen shows the port PoE status, Priority and Power Limit.
3. Check the Enable PoE checkbox to configure the selected port to use Power over Ethernet. To disable
PoE on a port, uncheck this box.
4. Select the Priority level for PoE on this port. The Priority level is used in cases where the switch’s PoE
power consumption exceededs the available power. When this happens, ports with higher Priority levels
will be given precedence over those with a lower Priority level.
5. Set the Power Limit (in watts) for this port’s PoE usage. Setting the Power Limit places a cap on the
maximum amount of power which can be drawn from the selected port.
6. Click OK to save and add the changes to the running configuration and close the dialog.
Page 68
3-24 Motorola RF Switch System Reference
3.3 Viewing Switch Configurations
Use the Configurations screen to review the configuration files available to the switch. The details of each
configuration can be viewed individually. Optionally, edit the file to modify its name or use the file as the
switch startup configuration. A file can be deleted from the list of available configurations or transferred to
a user specified location.
NOTE: To view the entire switch configuration using SNMP, the switch CLI provides a
better medium to review the entire switch configuration.
NOTE: The Motorola RF Management Software is a recommended utility to plan the
deployment of the switch and view its configuration once operational in the field.
Motorola RFMS can help optimize the positioning and configuration of a switch (and its
associated radios) in respect to a WLAN’s MU throughput requirements and can help
detect rogue devices. For more information, refer to the Motorola Web site.
To view the Configuration files available to the switch:
1. Select Switch > Configurations from the main menu tree.
The following information is displayed in tabular format. Configuration files (with the exception of
startup-config and running-config) can be edited, viewed in detail or deleted.
NameDisplays the name of each existing configuration file.
Size (Bytes)Displays the size (in bytes) of each available configuration file.
CreatedDisplays the date and time each configuration file was created. Use this
information as a baseline for troubleshooting problems by comparing event log
data with configuration file creation data.
Page 69
Switch Information 3-25
ModifiedDisplays the date and time each configuration file was last modified. Compare this
column against the Created column to discern which files were modified and make
informed decisions whether existing files should be further modified or deleted.
PathDisplays the path (location) to the configuration file.
2. To view the contents of a config file in detail, select a config file by selecting a row from the table and
click the View button. For more information, see Viewing the Detailed Contents of a Config File.
3. Select a configuration (other than the start-up-config or running config) and click the Install button to
install the file on the switch and replace the existing startup-config file.
If a file (for example, sample-config) is selected, a message displays stating, “When sample-config is
installed, it will replace start-up config. Are you sure you want to install sample-config.” Click Yes to
continue.
NOTE: Selecting either the startup-config or running-config does not enable the Edit
button. A different configuration must be available to enable the Edit function for the
purposes of replacing the existing startup-config.
4. To permanently remove a file from the list of configurations available to the switch, select a configuration
file from the table and click the Delete button.
If startup-config is deleted, a prompt displays stating the default switch startup-config will automatically
take its place. The switch running-config cannot be deleted.
5. To restore the system’s default configuration and revert back to factory default, click the Restore
Defaultsbutton.
NOTE: After setting the switch to revert to factory default settings, the system must be
rebooted before the default settings take effect. When this occurs, the switch IP address
may change.
6. Click the Transfer Files button to move a target configuration file to a secure location for later use. For
more information, see Transferring a Config File.
3.3.1 Viewing the Detailed Contents of a Config File
The View screen displays the entire contents of a configuration file. Motorola recommends a file be reviewed
carefully before it is selected from the Config Files screen for edit or designation as the switch startup
configuration.
1. Select a configuration file from the Configuration screen by highlighting the file.
2. Click the View button to see the contents of the selected configuration file.
Page 70
3-26 Motorola RF Switch System Reference
Use the up and down navigation facilities on the right-hand side of the screen to view the entire page.
3. The Page parameter displays the portion of the configuration file in the main viewing area.
The total number of pages in the file are displayed to the right of the current page. The total number of
lines in the file display in the Status field at the bottom of the screen.
Scroll to corresponding pages as required to view the entire contents of the file. To navigate to a specific
page, enter the page number in the text area (next to Page item) and click on the Gobutton. The source
parameter differs depending on the source selected.
4. Refer to the Status field for the current state of the requests made from the applet. Requests are any
“SET/GET” operation from the applet. The Status field displays error messages if something goes wrong
in the transaction between the applet and the switch.
5. Click the Refresh button to get the most recent updated version of the configuration file.
6. Click Closeto close the dialog without committing updates to the running configuration.
3.3.2 Transferring a Config File
Transfer a configuration file to and from the switch using the Tr an sf er screen. Transferring the switch
configuration is recommended to keep viable configurations available in a secure location. The following file
transfer configurations are possible:
• switch to switch, server or local disk
• server to switch
• local disk to switch
To transfer the contents of a configuration file:
Page 71
Switch Information 3-27
1. Click the Transfer Files button on the bottom of the Configuration screen.
2. Refer to the Source field to define the location and address information for the source config file.
FromSelect the location representing the source file’s current location using the From
drop-down menu. Options include Server, Local Disk and Switch.
FileSpecify a source file for the file transfer. If the switch is selected, the file used at
startup automatically displays within the File parameter.
UsingRefer to the Using drop down-menu to configure whether the log file transfer is
conducted using FTP or TFTP. FTP transfers require a valid user ID and password.
IP AddressEnter the IP Address of the server or system receiving the source configuration.
Ensure the IP address is valid or risk jeopardizing the success of the file transfer.
User IDEnter the User ID credentials required to transfer the configuration file from a FTP
server.
PasswordEnter the Password required to send the configuration file from an FTP server.
PathSpecify an appropriate Path name to the target directory on the local system disk
or server. The Target options are different depending on the target selected.
3. Refer to the Targ et field to specify the details of the target file.
ToUse the To drop-down menu to define the location of the configuration file.
Options include the switch (default location), external server or local disk.
File Use the File field to specify a target file for the file transfer. Use the File Browser
icon to search attached files systems for target file location.
4. Refer to the Status field for the current state of the requests made from the applet. Requests are any
“SET/GET” operation from the applet. The Status field displays error messages if something goes wrong
in the transaction between the applet and the switch.
5. Click the Transfer button when ready to move the target file to the specified location. Repeat the process
as necessary to move each desired configuration file to the specified location.
6. Click the Abort button to cancel the file transfer process before it is complete.
7. Click the Close button to exit the Transfer screen and return to the Config Files screen. Once a file is
transferred, there is nothing else to be saved within the Transfer screen.
Page 72
3-28 Motorola RF Switch System Reference
3.4 Viewing Switch Firmware Information
The switch can store (retain) two software versions (primary and secondary). Information supporting the two
versions displays within the Firmware screen. The Version column displays the version string. The Build
Time is the date and time each version was generated. Install represents thedate and time the upgrade
was performed. Next Boot indicates which version should be used on the next reboot. The Next Boot version
should match the Running Version, unless the system has failed over to another version.
To view the firmware files available to the switch:
1. Select Switch > Firmware from the main menu tree.
2. Refer to the following information displayed within the Firmware screen:
ImageDisplays whether a firmware image is the primary image or a secondary image.
The primary image is typically the image loaded when the switch boots.
VersionDisplays a unique alphanumeric version for each firmware file listed.
Current BootA check mark within this column designates this version as the version used by the
switch the last time it was booted. An “X” in this column means this version was
not used the last time the switch was booted.
Next BootA check mark within this column designates this version as the version to be used
the next time the switch is booted. An “X” in this column means this version will
not be used the next time the switch is booted. To change the boot designation,
highlight an image and click the Edit button.
Built TimeDisplays the time the version was created (built). Do not confuse the Built Time
with the time the firmware was last loaded on the switch.
Install TimeThe Install Time is the time this version was loaded with on the switch.
Periodically review this information to assess the relevance of older files.
Page 73
3. Refer to the Patch field for a listing of those Patches available to the switch. The name and version of
each patch file is displayed. Each patch file has an associated .txt file designation. the text file describes
nuances associated with the file that may make it optimal for use with the switch.
4. Select an existing firmware version and click the Edit button to change the firmware version used when
the switch is booted the next. For more information, see Editing the Switch Firmware.
5. Click on the Global Settings button to specify a firmware version for use with the failover image. For
more information, see Enabling Global Settings for the Image Failover.
6. Click on the Update Firmware button to update the firmware file loaded onto the switch. For more
information, see Updating the Switch Firmware.
NOTE: To apply a patch to the switch follow the same instructions for updating the
switch’s firmware.
7. To remove a patch, select it from amongst those displayed within the Patch field and click the Remove
Patch button.
3.4.1 Editing the Switch Firmware
Switch Information 3-29
The Edit screen enables the user to select a firmware file and designate it as the version used the next time
the switch is booted.
1. Select the primary firmware image from the Firmware screen.
2. Click the Edit button.
The Firmware screen displays the current firmware version and whether this version is used for the next
reboot.
3. Select the checkbox to use this version on the next boot of the switch.
4. To edit the secondary image, select the secondary image, click the Edit button and select the Use this
firmware on next reboot checkbox.
This firmware version will now be invoked after the next reboot of the switch.
5. Refer to the Status field for the current state of the requests made from the applet. Requests are any
“SET/GET” operation from the applet. The Status field displays error messages if something goes wrong
in the transaction between the applet and the switch.
6. Click the OK button to commit the changes made and exit the screen.
Page 74
3-30 Motorola RF Switch System Reference
3.4.2 Enabling Global Settings for the Image Failover
Use the Global Settings screen to specify a firmware version for use with the failover image.
SWITCH NOTE: The Global Settings for Image Failover is only available on the WS5100
switch. On the RFS6000 and RFS7000 switches the Global Settings button is not present
on the Firmware page.
1. Select an image from the table in the Firmware screen.
2. Click the Global Settings button.
3. Select the Enable Image Failover checkbox to load an alternative firmware version if the WLAN
module fails to load the selected version successfully after 2 reboot attempts.
4. Refer to the Status field for the current state of the requests made from the applet. Requests are any
“SET/GET” operation from the applet. The Status field displays error messages if something goes wrong
in the transaction between the applet and the switch.
5. Click OK to save and add the changes to the running configuration and close the dialog.
3.4.3 Updating the Switch Firmware
Use the Update screen to update the firmware version currently used by the switch.
NOTE: When performing a firmware update using the switch CLI, use the following
syntax (specific to FTP)
If using TFTP, use tftp://ipaddress/path/filename.
NOTE: When performing a firmware update using FTP be sure that TCP port 21 is open
between the switch and the FTP server where the firmware file is located.
1. Select an image from the table in the Firmware screen.
3. Use the From drop-down menu to specify the location from which the file is sent.
4. Enter the name of the file containing the firmware update in the File text field.
This is the file that will append the file currently in use.
5. From the Using drop down menu, select either FTP or TFTP as a medium to update the firmware.
a. Use FTP to get the firmware update from a File Transfer Protocol (FTP) server. A user account must
be established on the FTP server specified for the firmware update.
b. Use TFTP to get the firmware update from a Trivial File Transfer Protocol (TFTP) server.
SWITCH NOTE: On the RFS7000 users can also transfer firmware files using USB or
Compact Flash. On the RFS6000 users can also transfer firmware files using USB.
6. Enter the IP address for the FTP or TFTP server in the IP address field.
7. Enter the username for FTP server login in the User ID field.
8. Enter the password for FTP server login in the Password field.
9. Enter the complete file path for the file that contains the firmware update in the Path field.
10.Click the Do Update button to initiate the update.
A warning prompt displays. Upon confirming the firmware update, the switch reboots and completes the
firmware update.
CAUTION: When restarting or rebooting the switch, the Radius server is restarted
regardless of its state before the reboot.
!
11.Click OK to add the changes to the running configuration and close the dialog.
12.Refer to the Status field for the current state of the requests made from the applet. Requests are any
“SET/GET” operation from the applet. The Status field displays error messages if something goes wrong
in the transaction between the applet and the switch.
13.Click Cancel to close the dialog without committing updates to the running configuration.
Page 76
3-32 Motorola RF Switch System Reference
3.5 Switch File Management
Use the File Management screen to transfer configuration file to and from the switch and review the files
available.
3.5.1 Transferring Files
Use the Transfer Files screen to transfer files to and from the switch.Transferring files is recommended to
keep files in a secure location. The following file transfer options are available:
• Wireless Switch to Wireless Switch
• Wireless Switch to Server
• Server to Wireless Switch
To define the properties of the file transfer configuration:
1. Select Switch > File Management from the main menu tree.
2. Refer to the Source field to specify the details of the source file.
FromUse the From drop-down menu to select the source file’s current location. The
File Use the Browse button to navigate to a target file for transfer. If the switch is
options include Wireless Switch and Server. The following transfer options are
possible:
• Wireless Switch to Wireless Switch
• Wireless Switch to Server
• Server to Wireless Switch.
The parameters displayed in the Source and Targ et fields differ based on the
above selection. These different kinds of file transfer techniques are described in
the sections that follow.
selected from the From drop-down menu (within the Source field), the file used at
startup automatically displays.
Page 77
3.5.1.1 Transferring a file from Wireless Switch to Wireless Switch
To transfer a file from one switch to another:
1. Select Wireless Switch from the From drop-down menu
Switch Information 3-33
2. Use the Browse button to locate a target file for the file transfer.
3. Use the To drop-down menu (within the Target field) and select Wireless Switch. This defines the
location of the file.
4. Use the Browse button to define a location for the transferred file.
5. Click the Transfer button to complete the file transfer.
6. The Message section in the main menu area displays the file transfer message.
7. Click Abort at any time during the transfer process to abort the file transfer.
3.5.1.2 Transferring a file from a Wireless Switch to a Server
To transfer a file from the switch to a Server:
Page 78
3-34 Motorola RF Switch System Reference
1. Refer to the Source field to specify the source file. Use the From drop-down menu and select Wireless
Switch.
2. Use the Browse button and select a file for transfer.
3. Use the To drop-down menu (within the Target field) and select Server. This defines the transfer location
of the configuration file. Enter the file location marked to store the transferred file.
4. Use the Using drop down-menu to configure whether the log file transfer is conducted using FTP, TFTP,
HTTP or SFTP. This field display the default port for FTP,TFTP, HTTP or SFTP. The value in this field can be
configured as required. Enter the IP Address of the server receiving the source configuration. Ensure the
IP address is valid or risk jeopardizing the success of the file transfer. Enter the User ID credentials
required to transfer the configuration file from a FTP server.
SWITCH NOTE: On the RFS7000 users can also transfer files using USB or Compact
Flash. On the RFS6000 users can also transfer files using USB.
5. Enter the Password required to send the configuration file from an FTP server.
6. Specify the appropriate Path name to the target directory on the server. The target options are different
depending on the target selected.
7. Click the Transfer button to complete the file transfer. The Message section in the main menu area
displays the file transfer message.
8. Click Abort at any time during the transfer process to abort the file transfer.
3.5.1.3 Transferring a file from a Server to a Wireless Switch
To transfer a file from a Server to the switch:
Page 79
Switch Information 3-35
1. Refer to the Source field to specify the details of the source file. Use the From drop-down menu and
select Server.
2. Provide the name of the File.
3. Use the Using drop-down menu to configure whether the file transfer is conducted using FTP, TFTP or
HTTP.
FTP transfers require a valid user ID and password.
4. Enter an IP Address of the server receiving the configuration file. Ensure the IP address is valid or risk
jeopardizing the success of the file transfer.
5. Enter the User ID credentials required to transfer the configuration file from a FTP server.
6. Enter the Password required to send the configuration file from an FTP server.
7. Specify the appropriate Path name to the target directory on the server. The Target options are different
depending on the target selected.
8. Use the To drop-down menu (within the Target field) and select Wireless Switch.
9. Use the Browse button to browse and select the location to store the file marked for transfer.
10.Click the Transfer button to complete the file transfer. The Message section displays the status of the
file transfer message.
11.Click Abort button any time during the transfer process to abort the file transfer.
3.5.2 Viewing Files
Use the File System tab to review the files available to the switch. The switch maintains the following file
types:
SWITCH NOTE: The File System tab is only available on the RFS6000 and RFS7000
switches. The WS5100 does not have USB or Compact Flash ports and as such does not
support this feature.
•flash
Page 80
3-36 Motorola RF Switch System Reference
•nvram
• system
• Compact Flash
•USB 1
•USB 2
SWITCH NOTE: USB 1 is available on the RFS6000 and RFS7000 switches. USB2 and
Compact Flash are only available on the RFS7000 switch. Neither USB or Compact Flash
are supported on the WS5100 switch.
Transfer files between the switch and the server from any one of the above mentioned locations. Since
compact flash (CF) and USB are external memory locations, the File System window displays the status of
these devices. Transfer files to compact flash and USB only if they are connected and available.
To view the file systems currently available to the switch:
1. Select Switch > File Management from the main menu tree.
2. Select the File System tab.
3. Refer to the following File Systems information.
NameDisplays the memory locations available to the switch.
Page 81
Switch Information 3-37
AvailableDisplays the current status of the memory resource. By default, nvram and system
are always available.
• A green check indicates the device is currently connected to the switch and is
available.
• A red X indicates the device is currently not available.
FormattedThis displays the format status of the memory devices. This ensures that the
external and internal memory device store the files securely. A formatted memory
device is less prone to crash and loss of data.
• A green check mark indicates the device is currently connected to the switch
and is available.
• A red X indicates the device is currently not available.
4. Select CF, USB1 or USB2 and click the Format button (enabled only if the CF or USB are connected to the
switch) to check if the memory device is formatted and available. You will be prompted that proceeding
will erase all data on the disk and if you would like to proceed.
3.6 Configuring Automatic Updates
Use the Automatic Updates screen to enable a facility that will poll a server address (you designate) when
the switch is booted. If updates are found since the last time the switch was booted, the updated version is
uploaded to the switch the next time the switch is booted. Enable this option for either the firmware,
configuration file or cluster configuration file. Motorola recommends leaving this setting disabled if a review
of a new file is required before it is automatically uploaded by the switch.
To enable and configure the automatic update feature for switch firmware, configuration files and cluster
configurations:
1. Select Switch > Automatic Updates from the main menu tree.
Page 82
3-38 Motorola RF Switch System Reference
2. Refer to the Switch Configurationfield to enable and define the configuration for automatic
configuration file updates. If enabled, the located (updated) configuration file will be used with the
switch the next time the switch boots.
EnableSelect the Enable checkbox to allow an automatic configuration file update when
a newer (updated) file is detected (upon the boot of the switch) at the specified IP
address.
IP AddressDefine the IP address of the server where the configuration files reside. If a new
version is detected when the switch is booted, it is uploaded to the switch and
used upon the next boot of the switch.
User IDEnter the User ID required to access the FTP or TFTP server.
File Name (With
Path)
ProtocolUse the Protocol drop-down menu to specify the FTP, TFTP, HTTP, SFTP or
Password Enter the password required to access the server.
Provide the complete and accurate path to the location of the configuration files
on the server. This path must be accurate to ensure the most recent file is
retrieved.
resident switch FLASH medium used for the file update from the server. FLASH is
the default setting.
SWITCH NOTE: In addition to the Protocols listed, on the RFS7000 users can also autoupdate using USB or Compact Flash. On the RFS6000 users can also auto-update using
USB.
3. Refer to the Redundancy Configuration field to enable and define the configuration for automatic
cluster file updates.
EnableSelect the Enable checkbox to allow an automatic cluster file update when a new
(updated) file is detected (upon the boot of the switch) at the specified IP address.
IP AddressDefine the IP address of the server where the cluster files reside. If a new version
is detected when the switch is booted it will be uploaded to the switch and used
upon the next boot of the switch.
User IDEnter the User ID required to access the FTP or TFTP server.
File Name (With
Path)
ProtocolUse the Protocol drop-down menu to specify the FTP, TFTP, HTTP, SFTP or
Password Enter the password required to access the server.
Provide the complete and accurate path to the location of the cluster files on the
server. This path must be accurate to ensure the most recent file is retrieved.
resident switch FLASH medium used for the file update from the server. FLASH is
the default setting.
Page 83
Switch Information 3-39
4. Refer to the Firmware field to enable and define the configuration for automatic firmware updates. If
enabled, the located (updated) switch firmware is used with the switch the next time the switch boots.
EnableSelect the Enable checkbox to allow an automatic firmware update when a new
(updated) version is detected (upon the boot of the switch) at the specified IP
address.
IP AddressDefine the IP address of the server where the firmware files reside. If a new
version is detected when the switch is booted it will be uploaded to the switch
and used upon the next boot of the switch.
User IDEnter the User ID required to access the FTP or TFTP server.
File Name (With
Path)
ProtocolUse the Protocol drop-down menu to specify the FTP, TFTP, HTTP, SFTP or
Password Enter the password required to access the server.
VersionProvide the target firmware version to ensure the switch is upgrading to the
Provide the complete and accurate path to the location of the firmware files on the
server. This path must be accurate to ensure the file is retrieved.
resident switch FLASH medium used for the file update from the server. FLASH is
the default setting.
intended baseline.
5. Select the Start Update button to begin the file updates for the enabled switch configuration, cluster
configuration or firmware facilities.
6. Click the Apply button to save the changes to the configuration.
7. Click the Revert button to revert back to the last saved configuration.
Page 84
3-40 Motorola RF Switch System Reference
3.7 Viewing the Switch Alarm Log
Use the Alarm Log screen as an initial snapshot for alarm log information. Expand alarms (as needed)
for greater detail, delete alarms, acknowledge alarms or export alarm data to a user-specified location
for archive and network performance analysis.
To view switch alarm log information:
1. Select Switch > Alarm Logfrom the main menu tree.
2. Use the Alarm Log screen’s filtering options to view alarm log data by page or the by its entire content.
3. Select either of the two available options to view alarm log information:
View By PageSelect the View By Page radio button to view alarm log information on a per
page basis. Use the View By Page option to page through alarm logs. If there are
a large number of alarms, the user can navigate to the page that has been
completely loaded. All operations can be performed on the currently loaded data.
Enter a page number next to “Page” and click the
specific page.
View AllSelect the View All radio button to display the complete alarm log with in the
table. If there are a large number of alarms, the View All option will take several
minutes to load.
Gobutton to move to the
4. Refer to the table within the Alarm Log screen for the following information:
IndexDisplays the unique numerical identifier for trap events (alarms) generated in the
system. Use the index to help differentiate an alarm from others with similar
attributes.
StatusDisplays the current state of the requests made from the applet. Requests are any
“SET/GET” operation from the applet. The Status displays error messages if
something goes wrong in the transaction between the applet and the switch.
Page 85
Switch Information 3-41
Time StampDisplays the date, year and time the alarm was raised (as well as the time zone of
the system). The time stamp only states the time the alarm was generated, not the
time it was acknowledged.
SeverityDisplays the severity level of the event. Use this (non numerical and verbal)
description to assess the criticality of the alarms. Severity levels include:
• Critical
• Major
• Warning
• Informational
•Normal
Module NameDisplays the module name that triggered this alarm. Use this information to
assess if this alarm is a recurring problem or if it is an isolated incident.
TypeDisplays the alarm type.
MessageDisplays a detailed event message corresponding to the alarm event. It contains
an event specific message for information about the alarm. Use this value along
with the Details description for optimal problem event identification.
5. Select an alarm and click the Details button to display an alarm description along with a system
proposed solution and possible causes. For more information, see
Viewing Alarm Log Details.
6. Select the alarm(s) from those listed and click the Delete button to remove them from the list of alarms.
This is not recommended in instances where the problem is unacknowledged and the criticality has not
yet been assessed.
7. Select the unacknowledged alarm(s) from those listed and click the Acknowledge button to
acknowledge them.
8. Click the Export button to export the content of the table to a Comma Separated Values file (CSV).
3.7.1 Viewing Alarm Log Details
Use the Details option when additional information is required for a specific alarm to make an informed
decision on whether to delete, acknowledge or export the alarm.
To review switch alarm details:
1. Select Switch > Alarm Logfrom the main menu tree.
Page 86
3-42 Motorola RF Switch System Reference
2. Select an alarm and click the Details button.
3. Refer to the Alarm Details and Alarm Message for the following information:
DescriptionDisplays the details of the alarm log event. This information can be used in
conjunction with the Solution and Possible Causes items to troubleshoot the
event and determine how the event can be avoided in the future.
SolutionDisplays a possible solution to the alarm event. The solution should be attempted
first to rectify the described problem.
Possible Causes Describes the probable causes that could have raised this specific alarm.
Determine whether the causes listed can be remedied to avoid this alarm from
being raised in the future.
Alarm MessageDisplays the radio (and MAC address if relevant) reporting the alarm detail
information.
4. Click Close to exit the dialog.
3.8 Viewing Switch Licenses
Use the Licenses screen to install and add a new switch license.
To install a new license:
Page 87
1. Select Switch > Licenses from the main menu tree.
Switch Information 3-43
2. Refer to the Install License field for the following information:
License KeyEnter the license key required to install a particular feature. The license key is
returned when you supply the switch serial number to Motorola support.
Feature NameEnter the name of the feature you wish to install/upgrade using the license.
Serial NumberDisplays the serial number of the switch used for generating the license key.
3. Click the Install button to install the selected license.
4. Refer to the Feature Licenses table for the following license specific information:
Feature NameDisplays the name of the feature either installed or upgraded on the switch.
License CountDisplays the number of licenses applied while entering the license key.
License UsageLists the number of license in use. Determine whether this number adequately
represents the number of switches needed to deploy.
License KeyThe license key for the feature installed/upgraded.
5. Select a license from the table and click the Delete button to remove the license from the list available
to the switch.
Page 88
3-44 Motorola RF Switch System Reference
3.9 How to use the Filter Option
Use the Filter Option to sort the display details of screen that employ the filtering option as a means of
sorting how data is displayed within the screen.
1. Click the Show Filtering Option to expand the Filter Option zone, whenever it appears in any screen.
2. Enter the filter criteria as per the options provided in the Filter Option zone.
The parameters in the Filter Option field are populated with the parameters of the screen in which it
appears. Not all switch Web UI’s contain the filtering option.
3. Click the Filter Entire Table button to filter the entire table in which the filter zone appears.
The result of the filtering operation displays at the bottom of the table
4. Click the Turn Off Filtering button to disable the filtering option for the screen where it appears.
Filtering status (when filtering is turned off) displays at the bottom of the table.
5. Click the Hide Filtering Option button to hide the Filter Option zone.
Page 89
Network Setup
This chapter describes the Network Setup menu information used to configure the switch. This chapter
consists of the following switch Network configuration activities:
• Displaying the Network Interface
• Viewing Network IP Information
• Viewing and Configuring Layer 2 Virtual LANs
• Configuring Switch Virtual Interfaces
• Viewing and Configuring Switch WLANs
• Viewing Associated MU Details
• Viewing Access Port Information
• Viewing Access Port Adoption Defaults
• Viewing Adopted Access Ports
• Multiple Spanning Tree
NOTE: HTTPS must be enabled to access the switch applet. Ensure HTTPS access has
been enabled before using the login screen to access the switch applet.
Page 90
4-2 Motorola RF Switch System Reference Guide
4.1 Displaying the Network Interface
The main Network interface displays a high-level overview of the configuration (default or otherwise) as
defined within the Network main menu. Use the information to determine if items require additional
configuration using the sub-menu items under the main Network menu item.
NOTE: When the switch’s configuration is successfully updated (using the Web UI), the
effected screen is closed without informing the user their change was successful.
However, if an error were to occur, the error displays within the effected screen’s Status
field and the screen remains displayed. In the case of file transfer operations, the transfer
screen remains open during the transfer operation and remains open upon completion
(with status displayed within the Status field).
To view the switch’s Network configuration:
1. Select Networkfrom the main menu tree.
Page 91
Network Setup 4-3
2. Refer to the following information to discern if configuration changes are warranted:
DNS ServersDisplays the number of DNS Servers configured thus far for use with the switch. For more
information, see Viewing Network IP Information on page 4-4.
IP RoutesDisplays the number of IP routes for routing packets to a defined destination. For information
on defining IP Routes, see Configuring IP Forwarding on page 4-6.
Additional
Resolution Entries
Switch Virtual
Interfaces
Wireless LANsDisplays the number of WLANs currently defined on the switch. The switch has 32 default
Mobile UnitsDisplays the number of MUs currently associated to (and interacting with) the switch. The
Access PortsDisplays the number of Access Ports (APs) active on the switch. Access ports can be added
RadiosDisplays the number of AP radios detected over the switch managed network. Displayed
Displays the number of layer three (IP) address to layer two (MAC) address mappings. For
more information, see Viewing Address Resolution on page 4-8.
Displays the number of virtual interfaces (VLANs) defined thus far for the switch. New
VLANs can be defined or existing VLANs can be modified as needed. For more information,
see Configuring Switch Virtual Interfaces on page 4-13.
WLANs. New WLANs can be added as needed, and
assignments and security schemes modified. For more information, see
Configuring Switch WLANs on page 4-21.
details of individual MUs can be displayed as needed. For more information, see Viewing
Associated MU Details on page 4-76.
or existing APs can have their VLAN assignments changed, their descriptions modified and
their current authentication and encryption schemes modified.
Viewing Access Port Information on page 4-85.
with this information is the number of radios detected that have been adopted by the switch.
For more information, see Configuring Access Port Radios on page 4-85.
their descriptions, VLAN
Viewing and
For more information, see
The Apply and Cancel buttons are greyed out within this screen, as there is no data to be configured or
saved.
Page 92
4-4 Motorola RF Switch System Reference Guide
4.2 Viewing Network IP Information
Use the Internet Protocol screen to view and configure network associated IP details. The Internet Protocol
screen contains tabs supporting the following configuration activities:
• Configuring DNS
• Configuring IP Forwarding
• Viewing Address Resolution
4.2.1 Configuring DNS
Use the Domain Name System tab to view Server address information and delete or add severs to the list
of servers available. To configure DNS:
1. Select Network > Internet Protocol from the main tree menu.
2. Select the Domain Network System tab (displayed by default).
Use the Show Filtering Options link to view the details displayed in the table.
3. The Domain Name System tab displays DNS details in a tabular format.
Server IP AddressDisplays the IP address of the domain name server(s) the system can use for
Server TypeDisplays whether the DNS IP address entry has been created statically (manually)
4. Select an IP Address from the table and click the Delete button to remove the selected entry from the list.
5. Click the Add button to display a screen used to add another domain name server. For more information,
see Adding an IP Address for a DNS Server on page 4-5.
resolving domain names to IP addresses. Domain look up order is determined by
the order of the servers listed. The first server queried is the first server displayed.
Therefore, ensure obsolete addresses are periodically removed.
or dynamically. The DHCP server provides the dynamic DNS IP address entry
displayed. A static DNS IP address can be created by clicking the Add button.
Page 93
6. Click the Global Settings button to open a screen that allows the domain lookup to be enabled/disabled
and the domain name to be specified. For more information, see Configuring Global Settings on page 4-5.
4.2.1.1 Adding an IP Address for a DNS Server
Add an IP address for a new domain server using the Add screen.
1. Click the Add button within the Domain Network System screen.
The new Configuration screen displays enabling you to add IP address for the DNS Server.
2. Enter the Server IP Address to define the IP address of the new static domain name server.
3. Refer to the Status field for the current state of the requests made from applet. This field displays error
messages if something goes wrong in the transaction between the applet and the switch.
Network Setup 4-5
4. Click OK to use the changes to the running configuration and close the dialog.
5. Click Cancel to close the dialog without committing updates to the running configuration.
4.2.1.2 Configuring Global Settings
Use the Global Settings screen to query domain name servers to resolve domain names to IP addresses.
Use this screen to enable/disable the Domain look up, which allows you to use commands like ping,
traceroute etc. using hostnames rather than IP addresses.
1. Click the Global Settings button in the main Domain Network System screen.
A Configuration screen displays for editing the DNS settings of the server.
2. Select the Domain Look Up checkbox to enable the switch to query domain name servers to resolve
domain names to IP addresses.
NOTE: The order of look up is determined by the order of the servers within Domain
Name System tab. The first server queried is the first server displayed.
3. Enter a Domain Namein the text field. This is the switch’s domain.
4. Refer to the Status field for the current state of the requests made from applet. This field displays error
messages if something goes wrong in the transaction between the applet and the switch.
5. Click OK to use the changes to the running configuration and close the dialog.
Page 94
4-6 Motorola RF Switch System Reference Guide
6. Click Cancel to close the dialog without committing updates to the running configuration.
4.2.2 Configuring IP Forwarding
The IP Forwarding table lists all the routing entries to route the packets to a specific destination. To view the
IP forwarding configuration:
1. Select Network > Internet Protocol from the main tree menu.
2. Select the IP Forwarding tab.
Use the Filtering Option to view the details displayed in the table.
3. The read-only IP Forwarding tab displays the current status between VLANs. To toggle the status of
routing between VLANs, use the Enable/Disable options located at the bottom of the screen.
The following details display in the table:
Destination SubnetDisplays the mask used for destination subnet entries. The Subnet Mask is the IP
mask used to divide internet addresses into blocks (known as subnets). A value of
255.255.255.0 will support 256 IP addresses.
Subnet MaskDisplays the mask used for destination subnet entries. The Subnet Mask is the IP
mask used to divide internet addresses into blocks (known as subnets). A value of
255.255.255.0 will support 256 IP addresses.
Gateway AddressDisplays the IP address of the Gateway used to route the packets to the specified
destination subnet. Do not set the gateway address to any VLAN interface used
by the switch.
InterfaceDisplays the interface name with which the destination subnet entries are
attached.
Page 95
ProtocolDisplays the name of the routing protocol with which this route was obtained.
Possible values are:
• Static — Routes are statically added by the operator.
• DHCP — Routes obtained from the DHCP server.
• Connected — Routes automatically installed by the switch for directly
connected networks based on interface IP addresses.
• Kernel/ ICMP — Routes added as a result of receiving an ICMP redirect from
an intermediate router.
ActiveWhen IP Forwarding is enabled for the selected subnet, a green check displays in
the Active column. A red X defines the subnet as disabled.
4. Select an entry and click the Delete button to remove the selected entry from the IP forwarding table.
5. Click the Add button to create a new static route. For more information, see Adding a New Static Route
on page 4-7.
6. Click Enable (to allow) or Disable (to deny) routing between VLANs.
4.2.2.1 Adding a New Static Route
Network Setup 4-7
Use the Add screen to add a new destination subnet, subnet mask and gateway for routing packets to a
defined destination. Use the screen when an existing destination subnet does not meet the needs of the
network.
To add a new static route:
1. Click the Add button.
A new Configuration screen displays enabling you to add a new destination subnet, subnet mask and
gateway for routing packets to a defined destination.
2. In the Destination Subnet field, enter an IP address to route packets to a specific destination address.
3. Enter a subnet mask for the destination subnet in the Subnet Mask field.
The Subnet Mask is the IP mask used to divide internet addresses into blocks known as subnets. A value
of 255.255.255.0 support 256 IP addresses.
4. In the Gateway Address field, enter the IP address of the gateway used to route the packets to the
specified destination subnet. Do not set the gateway address to any VLAN interface used by the switch.
5. Refer to the Status field for the current state of the requests made from applet. This field displays error
messages if something goes wrong in the transaction between the applet and the switch.
6. Click OK to use the changes to the running configuration and close the dialog.
Page 96
4-8 Motorola RF Switch System Reference Guide
7. Click Cancel to close the dialog without committing updates to the running configuration.
4.2.3 Viewing Address Resolution
The Address Resolution table displays the mapping of layer three (IP) addresses to layer two (MAC)
addresses. To view address resolution details:
1. Select Network > Internet Protocol from the main tree menu.
2. Select the Address Resolution tab.
3. Refer to the Address Resolution table for the following information:
Interface
IP Address
MAC Address
Type
Displays the name of the actual interface where the IP address was
found (typically a VLAN).
Displays the IP address being resolved.
Displays the MAC address corresponding to the IP address being
resolved.
Defines whether the entry was added statically or created
dynamically in respect to network traffic. Entries are typically
static.
4. Click the Clear button to remove the selected AP entry if no longer usable.
Page 97
4.3 Viewing and Configuring Layer 2 Virtual LANs
A virtual LAN (VLAN) is similar to a Local Area Network (LAN), however devices do not need to be connected
to the same segment physically. Devices operate as if connected to the same LAN, but could be connected
at different physical connections across the LAN segment. The VLAN can be connected at various physical
points but react as if it were connected directly. One of the biggest advantages of a VLAN, is when a
computer is physically moved to another location, it can stay on the same VLAN without reconfiguration. The
switch can support multiple VLANs. Use the Layer 2 Virtual LANs screen to view and configure VLANs by
Port and Ports by VLAN information. Refer to the following VLAN configuration activities:
• Viewing and Configuring VLANs by Port
• Viewing and Configuring Ports by VLAN
4.3.1 Viewing and Configuring VLANs by Port
1. Select Network > Layer 2 Virtual LANs from the main menu tree. VLAN by Port details display within
the Virtual LANs screen.
Network Setup 4-9
2. Refer to following details within the table:
Name Displays the name of the VLAN to which the switch is currently connected.
Mode
Native VLANDisplays the tag assigned to the native VLAN.
It can be either Access or Trunk.
•Access– This ethernet interface accepts packets only form the native VLANs.
•Trunk– The Ethernet interface allows packets from the given list of VLANs you
add to the trunk.
Page 98
4-10 Motorola RF Switch System Reference Guide
Allowed VLANsDisplays VLAN tags allowed on this interface
Native VLAN TaggedDisplays if the Native VLAN for each port is tagged or not. The column displays a
green check mark if the Native VLAN is tagged. If the Native VLAN is not tagged
the column will display a red “x”.
A Native VLAN is the VLAN which untagged traffic will be directed over when
using a port in trunk mode.
SWITCH NOTE: For Adaptive AP to work properly with RFS7000 you need to have
independent and extended WLANs mapped to a different VLAN than the ge port.
3. Select a record from the table and click the Edit button to modify the record. For more information, see
Editing the Details of an Existing VLAN by Port on page 4-10.
4.3.2 Editing the Details of an Existing VLAN by Port
To revise the configuration of an existing VLAN:
1. Select Network > Virtual LANs from the main menu tree.
2. Select an Ethernet for which you want to configure the VLAN and click on the Edit button.
The system prompts you with a Port VLAN Change Warning message stating communication
disruptions could occur with the switch.
3. Click OK to continue.
4. Use the Edit screen to modify the VLAN’s mode, access VLAN and allowed VLAN designation.
Page 99
Network Setup 4-11
5. Use the Edit screen to modify the following:
NameDisplays a read only field and with the name of the Ethernet to which the VLAN is
associated.
ModeUse the drop-down menu to select the mode. It can be either:
• Access – This Ethernet interface accepts packets only form the native VLANs.
If this mode is selected, the Allowed VLANs field is unavailable.
• Trunk–The Ethernet interface allows packets from the given list of VLANs you
can add to the trunk.
Native VLANUse this field to change the tag assigned to the native VLAN.
Allowed VLANsThis section has the following 2 options (and is only available when Trunk is
selected from the Mode drop-down menu):
• No VLANs– Select this option if you do not wish to add any additional VLANs.
• Selected VLANs– Select this option if you wish to add additional VLANs.
6. Refer to the Status field for the current state of the requests made from applet. This field displays error
messages if something goes wrong in the transaction between the applet and the switch.
7. Click OK to use the changes to the running configuration and close the dialog.
8. Click Cancel to close the dialog without committing updates to the running configuration.
4.3.3 Viewing and Configuring Ports by VLAN
A Virtual Local Area Network (VLAN) is a switched network segmented by function or application rather than
a traditional LAN segmentation (based on physical location). VLANs allow a greater level of flexibility and
enable changes to the network infrastructure without physically disconnecting network equipment.
To view VLAN by Port information:
1. Select Network > Layer 2 Virtual LANs from the main menu tree.
Page 100
4-12 Motorola RF Switch System Reference Guide
2. Select the Ports by VLAN tab.
VLAN details display within the VLANs by Port tab.
3. Highlight an existing VLAN and click the Edit button. The system displays a Port VLAN Change Warning
message. Be advised, changing VLAN designations could disrupt access to the switch.
4. Click OK to continue. A new window displays wherein the VLAN assignments can be modified for the
selected VLAN.
SWITCH NOTE: The ports available vary by switch.
On the WS5100, the available ports are eth1 and eth2.
On the RFS6000, the available ports are ge1, ge2, ge3, ge4, ge5, ge6, ge7, ge8 and up1.
On the RFS7000, the available ports are ge1, ge2, ge3 and ge4.