Motorola MC74F398DW, MC74F398N, MC54F398J Datasheet

4-189
FAST AND LS TTL DATA
QUAD 2-PORT REGISTER
The MC54/74F398 is the logical equivalent of a quad 2-input multiplexer feeding into four edge-triggered flip-flops. A common Select input determines which of the two 4-bit words is accepted. The selected data enters the flip­flops on the rising edge of the clock.
Select Inputs from Two Data Sources
Both True and Complement Outputs
1 2 3 4 5 6 7
141517181920
V
CC
16
QdQ
dI0dI1d
I
0c
I
1c
Q
aS
Q
a
I
0aI1a
I
0b
I
1b
CONNECTION DIAGRAM (TOP VIEW)
8 9 10
111213
Q
c CP
Q
c
Q
b
GNDQ
b
LOGIC DIAGRAM
NOTES: This diagram is provided only for the understanding of logic operations and should not be used to estimate propagation delays.
D
CP
Q
a
Q
a
Q
b
Q
b
Q
c
Q
c
Q
d
Q
d
I
0a
S
I
1a
I
0b
I
1b
I
0c
I
1c
I
0d
I
1d
CP
D
CP
D
CP
D
CP
QUAD 2-PORT REGISTER
FAST SCHOTTKY TTL
20
1
DW SUFFIX
SOIC
CASE 751D-03
20
1
N SUFFIX
PLASTIC
CASE 738-03
J SUFFIX
CERAMIC
CASE 732-03
20
1
MC54/74F398
ORDERING INFORMATION
MC54FXXXJ Ceramic MC74FXXXN Plastic MC74FXXXDW SOIC
I0a I1a I0b I1b I0c I1c I0d I
1d
S
CP
Q
a
Q
a
Q
b
Qb Q
c
Q
c
Q
d
Q
d
LOGIC SYMBOL
4 5 7 6 14 15 17 16
1
11
2 3 9 8 12 13 19 18
VCC = PIN 20 GND = PIN 10
4-190
FAST AND LS TTL DATA
MC54/74F398
FUNCTIONAL DESCRIPTION
The MC54/74F398 is a high-speed quad 2-port register. It
will select four bits of data from either of two sources (Ports) under control of a common Select input (S). The selected data is transferred to a 4-bit output register synchronous with the LOW-to-HIGH transition of the Clock input (CP). The 4-bit D-
type output register is fully edge-triggered. The Data inputs (I0x, I1x) and Select input (S) must be stable only a setup time prior to and hold time after the LOW-to-HIGH transition of the Clock input for predictable operation. The MC54/74F398 has both Q and Q
outputs.
Inputs Outputs
S
I
0
I
1
Q
Q I I
h h
I
h X
X
X X
I
h
L H
L H
H
L
H
L
H = HIGH Voltage Level L = LOW Voltage Level h = HIGH Voltage Level one setup time prior to the LOW-to-HIGH clock transition I = LOW Voltage Level; one setup time prior to the LOW-to-HIGH clock transition X = Don’t Care
FUNCTION TABLE
GUARANTEED OPERATING RANGES
Symbol Parameter Min Typ Max Unit
V
CC
Supply Voltage 54, 74 4.5 5.0 5.5 V
T
A
Operating Ambient Temperature Range 54 –55 25 125 °C
74 0 25 70
I
OH
Output Current – High 54, 74 –1.0 mA
I
OL
Output Current – Low 54, 74 20 mA
DC CHARACTERISTICS OVER OPERATING TEMPERATURE RANGE (unless otherwise specified)
Limits
Symbol Parameter Min Typ Max Unit Test Conditions
V
IH
Input HIGH Voltage 2.0 V Guaranteed Input HIGH Voltage
V
IL
Input LOW Voltage 0.8 V Guaranteed Input LOW Voltage
V
IK
Input Clamp Diode Voltage –1.2 V IIN = –18 mA VCC = MIN
V
OH
Output HIGH Voltage 54, 74 2.5 3.4 V IOH = – 1.0 mA VCC = 4.5 V
74 2.7 3.4 V IOH = – 1.0 mA VCC = 4.75 V
V
OL
Output LOW Voltage 0.35 0.5 V IOL = 20 mA VCC = MIN
I
IH
Input HIGH Current 20 µA VIN = 2.7 V VCC = MAX
100 µA VIN = 7.0 V
I
IL
Input LOW Current –0.6 mA VIN = 0.5 V VCC = MAX
I
OS
Output Short Circuit Current (Note 2) –60 –150 mA V
OUT
= 0 V VCC = MAX
I
CC
Power Supply Current 25 38 mA VCC = MAX VIN = GND
CP =
NOTES:
1. For conditions shown as MIN or MAX, use the appropriate value specified under guaranteed operating ranges.
2. Not more than one output should be shorted at a time, nor for more than 1 second.