Motorola MB100 User Manual

MB100 1 GHz Amplifier
STARLINE® Series
Motorola’s 1 GHz STARLINE
®
Mini-Bridger® series amplifier, model MB100*, leads the industry in features and performance and is designed to meet the needs of today's expanding broadband communication networks. This two-way capable dual output amplifier offers high gain, high output levels, ergonomics, superior distortion performance, multiple diplex filter options, 16 dB return loss, and Bode equalization. The MB100 also allows optional advanced features such as ingress control switching and status monitoring. A third output is user-configurable via splitter or directional coupler plug-in. Single output models are also available.
ENHANCED GALLIUM ARSENIDE
The MB100 two-way amplifier offers 1 GHz bandwidth capability, high gain, high output level, ergonomics, and superior distortion performance with the option to bench upgrade to N-split (5-85/104-1003 MHz) in the future.
The MB100 uses Enhanced Gallium Arsenide (E-GaAs) hybrids. This second generation technology provides superior distortion performance in CTB and CSO over the standard GaAs technology. Compared to silicon and competing GaAs technology, E-GaAs distortion performance remains linear at significantly higher output levels. This higher output level allows the customer to maximize system performance and reduce system costs. We encourage our customers to contact their Motorola Account Representative to determine the optimal levels for their systems.
HIGH GAIN
The MB100 also offers high gain, which allows the operator to hold existing amplifier locations during system upgrades thereby reducing system costs such as maintenance, installation and powering.
BENEFITS INCLUDE:
1003 MHz Enhanced Gallium Arsenide (E-GaAs) power doubling technology
High gain
High output level
Multiple diplex filter options
Future N-split (5-85/104-1003 MHz) availability
Ease-of-use ergonomics
16 dB return loss
60/90 V powering
Meets Telcordia GR-1098-Core voltage surge
requirements using surge waveforms as described in IEEE C62.41
FCC, CENELEC and CCC approved
RoHS compliant models available Q1 2007
Bode equalization (thermal or auto controlled)
15 Ampere AC capability
Optional return path ingress control and status monitor
Power factor corrected power supply
Directional coupler –20 dB test points
Motorola, Inc. 101 Tournament Drive Horsham, PA 19044
www.motorola.com/broadband
04.03.07 Rev 8
MOTOROLA, the Stylized M Logo, STARLINE, Mini-Bridger, and LIFELINE are registered in the US Patent & Trademark Office.
All other product or service names are the property of their respective owners.
©
Motorola, Inc. 2006. All rights reserved.
Specifications are subject to change without notice.
BACKWARD COMPATIBILITY
The MB100 electronics package can be made backward compatible with the 10-Amp MB*/* housing by installing the MB­15A Kit or the MB-15A Kit II. These kits contain 50 mil gold plated platform assemblies. This makes it possible for the amplifier to carry 15 Amperes continuous through the input or output ports. There is also a “low current” (10A) model available that can be ordered as an electronics module (no housing included), which is backward compatible with the 10­Amp MB housing, without the use of a kit.
FORWARD PATH
The operational gain of the MB100 is 42 dB, with 16 dB return loss. Output level control is achieved through the use of an interstage Bode equalizer, which compensates for coaxial cable attenuation changes due to temperature. Equalization may be controlled manually, with a thermal drive unit (TDU), or with a single pilot closed loop automatic drive unit, model ADU-* (analog pilot) or QADU-* (QAM pilot). Both the ADU and QADU boards are common to the STARLINE family of amplifiers (with the exception of the SLE). ADUs utilize Surface Acoustic Wave (SAW) filters for determining pilot frequency. This improves amplifier stability over temperature.
To further ensure system flexibility, installation ease and maintenance, the amplifier is engineered for compatibility with standard accessories, such as attenuators, equalizers, ADUs or QADUs, return amplifiers, automotive fuses and FTEC crowbar circuits.
For an optional third output, the MB100 utilizes splitters (model SP100) and directional couplers (model DC100/*). The SP100, DC100/8, DC100/10, and DC100/12 offer superior performance to 1 GHz.
The MB100 uses modular diplex filters, which can be changed for a different frequency split as required. The amplifier is available with S-split filters for a 5-40 MHz return and a 52-1003 MHz forward band. K-splits (5-42 MHz/54-1003 MHz), J-splits (5-55 MHz/70-1003 MHz), and A-splits (5-65 MHz/85-1003 MHz) are also available. The N-split (5-85 MHz/104­1003 MHz) option is currently in development. These same filters can be used for all US-style Motorola RF distribution amplifiers (models BLE, MB/MBE, BT).
RETURN PATH
High gain return amplifier kits can be ordered which provide 20 dB minimum station gain. Return path equalizers from 0 to 12 dB can be customer selected. Optional features include thermal compensation and ingress control switching. Thermal compensation comes in the form of a plug-in JXP-TH*C, which stabilizes gain and match over temperature extremes.
Also available is Ingress Control Switching (ICS) in 3 states. This pin diode attenuator circuit can lower levels by 6 dB or by 38 dB with a controlled slew rate for minimum bit errors. The LIFELINE
®
Mini-Bridger amplifier transponder (available
directly from AM Networks) is required to operate the Ingress Control Switch from a remote location.
Model Availability
To reduce customer costs and to accommodate customer specific needs, the STARLINE MB100 can be ordered in a
variety of different models. Please refer to the MB100 ordering information below for options.
Motorola, Inc. 101 Tournament Drive Horsham, PA 19044
www.motorola.com/broadband
04.03.07 Rev 8
MOTOROLA, the Stylized M Logo, STARLINE, Mini-Bridger, and LIFELINE are registered in the US Patent & Trademark Office.
2
All other product or service names are the property of their respective owners.
©
Motorola, Inc. 2006. All rights reserved.
Specifications are subject to change without notice.
STARLINE® Enhanced Gallium Arsenide
1 GHz Mini-Bridger Amplifier
PARAMETER UNITS NOTE FORWARD
Passband MHz 1 5-40
Flatness dB 2 ± 0.50
Minimum Full Gain dB 3 NA
Operational Gain dB 4 20
Manual Bode Slope Control Range dB 5 NA
Interstage Equalizer Slope dB 6 NA
Noise Figure 40/52/1003MHz dB 7 8 / NA / NA
Reference Frequency MHz 8 1003 / 550 / 52
Output Level dBmV 45 / 44 / 37 35 flat
Channel Loading NTSC 79 6
Compressed data loading MHz 20 450 NA
Distortion (max) CTB dBc 9,19,21 76.5 88
Test Point (all) dB 12
Return Loss dB 13
Hum Modulation @ 12A dBc 14 60 (5 - 10 MHz)
Hum Modulation @ 15A 14 55 (5 - 10 MHz)
DC Voltage VDC 15
Current DC mA 16 1610
DC Ripple mV
Power Consumption W 48
AC Input Voltage Range VAC
AC Current Draw A 17 With Return
AC Bypass Current All Ports A 17
Group Delay (max) 18
Housing Dimensions 15.4"L x 5.5"W x 9.6"D 39.1cm x 13.97cm x 24.3 cm
Weight 15 lbs 6.8 kg
Motorola, Inc. 101 Tournament Drive Horsham, PA 19044
www.motorola.com/broadband
04.03.07 Rev 8
Ambient Operating Temperature -40° to +140° F -40° to +60° C
MB100 Specifications
All specifications stated as worst-case over temperature unless otherwise noted.
2 Port, Parallel E-GaAs Hybrid
MB100S Specifications
52-1003
± 0.70
46
42
± 4
14 ±1
NA / 8 / 8
XM dB 10,19 68.5 77
CSO dBc 9,11,19 71 81
20 ±1.0
16
70 (52 - 900 MHz)
65 (901 - 1003 MHz)
65 (52 - 900 MHz)
60 (901 - 1003 MHz)
1475
15 P-P
44.0
38 - 90
Forward Only
@90 VAC 0.55
@75 VAC 0.68
@60 VAC 0.81
@53 VAC 0.92
@45 VAC 1.08
@38 VAC 1.31
55.25 to 58.83 MHz nSec NA
5.0 to 6.5 MHz nSec 45
10.0 to 11.5 MHz nSec 10
33.5 to 35.0 MHz nSec 12
38.5 to 40.0 MHz nSec 32
3
MOTOROLA, the Stylized M Logo, STARLINE, Mini-Bridger, and LIFELINE are registered in the US Patent & Trademark Office.
All other product or service names are the property of their respective owners.
0.51
0.62
0.74
0.85
0.95
1.2
15 (or 10 amp option)
32
NA
NA
NA
NA
Specifications are subject to change without notice.
RETURN
RA-KIT/H
70 (11 - 40 MHz)
65 (11 - 40 MHz)
©
Motorola, Inc. 2006. All rights reserved.
Specification Notes:
1. Operating passband of station. Diplex filters are plugged into the electronic chassis.
2. Referenced to the average gain across the stated passband.
3. Minimum full gain at 1003 MHz includes loss of equalizer but Bode slope reserves have not been set. Return gain includes loss of SRE-*-4 return equalizer.
4. Operational gain includes loss of slope reserves as well as equalizer.
5. Amount of Bode slope control range from midpoint (typical setting is -4 dB at 1003 MHz @ 20°C). This control should not be used for gain reduction.
6. Amount of slope created and cable equivalence of fixed interstage equalizer. Interstage equalizer is a plug-in.
7. Noise Figure is specified at the cable entry facility of the housing and includes the loss of 1 dB for the pre-stage equalizer. The return Noise Figure includes the station loss preceding the RF hybrid.
8. Frequencies that relate the picture carriers or passband edges to the specified output levels and tilts.
9. Measured with CW carriers and spectrum analyzer over specified temperature range. References the worst-case channel. Specifications are compliant with the test methods as stated in NCTA RECOMMENDED PRACTICES FOR MEASUREMENTS ON CABLE TELEVISION SYSTEMS.
10. Measured with wave analyzer and synchronous, 100% depth modulated channels. References the worst-case channels over specified temperature range. Specifications are compliant with the test methods as stated in NCTA RECOMMENDED PRACTICES FOR MEASUREMENTS ON CABLE TELEVISION SYSTEMS.
11. Composite Second Order distortion refers only to those beat clusters that fall +0.75 MHz and +1.25 MHz above the subject picture carrier. CSO beat clusters that have a -0.75 MHz and -1.25 MHz relationship to the subject picture carrier are not included in this specification.
12. Test points should be used with GFAL adaptor.
13. Match measurement at the station input and output, cable-entry facilities, at the specified passbands for operational gain.
14. Measured with the stated AC Bypass Current.
15. Measured at the power connector.
16. Current draw at +24.0 VDC.
17. AC current is stated in RMS continuous. A 10-amp compatible electronics package is also available for installing into older 10-amp housings during upgrades.
18. Group Delay is specified for standard NTSC video, where delay is the delta from picture carrier to 3.58 MHz color subcarrier. Reverse delay is in a 1.5 MHz bandwidth.
19. Distortion numbers are worst case over temperature in a cascade.
20. The compressed data loading is QAM carriers and are –6 dB relative to the analog CW carriers.
21. CTB (Composite Triple Beat). At the specified channel loading, Enhanced Gallium Arsenide performance varies on a two point three-for-one (2.3:1) basis with amplifier output level.
MB100 Block Diagram
Input
port 1
-1.7 dB F
RF/ AC
AC
**
-20 dB
RF
-1.0 dB R
Fuse
TP
-1.0dB
H
L
-1.0dB
**
SFE or SCS
-1.0dB
**
To status
monitor
-20 dB TP
JXP-B
-0.4dB
+24 dB
**
Therm
PP
Cntrl
-0.5dB
** **
SRE
THERM
24 Vdc
Power supply
~ -7.0 dB
**
HPF
JXP-B
RC
Manual Auto
+30.0 dB
-6.5 dB
** **
BODE
ADU/
TDU
-0.3dB
LPF
JXP-B
-0.4 dB
-1.0 dB
MDR
Status
Monitor
Input
-16 dB
**
**
JXP-B
+23 dB
PP
-4.0 dB
-4.0 dB
JXP-B
****
4 dB
tilt
** **
** **
OnBrd Atten
JXPICS
JXPICS
-4.0 dB
-4.0 dB
JXP-B
JXP-B
JXP-B
JXP-B
**
**
-20 dB
+20 dB
PD
+20 dB
PD
TP
TP
-20 dB
**
-0.4dB
-1.0dB
H
L
-1.0dB
-0.4dB
-1.0dB
H
L
-1.0dB
**
-20 dB TP
-1.7 dB F
-1.0 dB R
-2.0 dB F
**
DC/ SP/
JMP
-1.0dB R
RF RF/AC AC
Fuse
(Status Monitor Output)
-20 dB TP
RF
AC
RF
RF/ AC
**** **
Fuse
Port
2
RF/ AC
AC
Port
4
Port
3
Fuse
Motorola, Inc. 101 Tournament Drive Horsham, PA 19044
www.motorola.com/broadband
04.03.07 Rev 8
**
Plug-in
module
DC
SP
JMP
4
MOTOROLA, the Stylized M Logo, STARLINE, Mini-Bridger, and LIFELINE are registered in the US Patent & Trademark Office.
All other product or service names are the property of their respective owners.
©
Motorola, Inc. 2006. All rights reserved.
Specifications are subject to change without notice.
MB100 Ordering Information
Model Description
MB100S-2HQXH-F
MB100S-2HAXH-F
MB100S-2HTXH-F
MB100S-2HXXH-F
MB100S-1HXXH-F
MB100S-2HSXH-F
MB100S-2HXXH-E15 MB2-100SH (“vanilla” model)
MB100K-2HQXH-F
MB100K-2HAXH-F
MB100K-2HTXH-F
MB100K-2HXXH-F
MB100K-1HXXH-F
MB100K-2HSXH-F
MB100K-2HXXH-E15 MB2-100KH (“vanilla” model)
MB100A-2HXXH-F-R
MB100J-2HXXH-F-R
Required Accessories
SFE-100-0 SFE-100-1 to -22 SCS-1 to SCS-10 SRE-*-* Starline Return Equalizer, 5-40 MHz (S-split), 5-42 (K-split), 5-55 (J-split), 5-65 (A-split),
JXP-*B Plug-in attenuator/pad (values 0 to 26 dB, in 1 dB steps)
Optional Accessories
SP100 DC100/8 DC100/10 DC100/12
5-40 / 52-1003 MHz S-split, two output, 42 dB high gain forward, QAM ADU 609.00 MHz gain control, 14 dB internal slope, high gain return, full station 721000-001-00 5-40 / 52-1003 MHz S-split, two output, 42 dB high gain forward, ADU 499.25 MHz gain control, 14 dB internal slope, high gain return, full station 721000-002-00 5-40 / 52-1003 MHz S-split, two output, 42 dB high gain forward, TDU gain control, 14 dB internal slope, high gain return, full station 721000-003-00 5-40 / 52-1003 MHz S-split, two output, 42 dB high gain forward, manual gain control, 14 dB internal slope, high gain return, full station 721000-004-00 5-40 / 52-1003 MHz S-split, one output, 42 dB high gain forward, manual gain control, 14 dB internal slope, high gain return, full station 721000-005-00 5-40 / 52-1003 MHz S-split, two output, 42 dB high gain forward, QAM ADU 711.00 MHz gain control, 14 dB internal slope, high gain return, full station 5-40 / 52-1003 MHz S-split, two output, 42 dB high gain forward, manual gain control, 14 dB internal slope, high gain return, 15A electronics module only (no housing) 5-40 / 52-1003 MHz S-split, 2-output, 42 dB high gain forward, manual gain control, 14 dB internal slope, no return, standard surge arrestor (no FTEC), full station 5-42 / 54-1003 MHz K-split, two output, 42 dB high gain forward, QAM ADU 609.00 MHz gain control, 14 dB internal slope, high gain return, full station 5-42 / 54-1003 MHz K-split, two output, 42 dB high gain forward, ADU 499.25 MHz gain control, 14 dB internal slope, high gain return, full station 5-42 / 54-1003 MHz K-split, two output, 42 dB high gain forward, TDU gain control, 14 dB internal slope, high gain return, full station 5-42 / 54-1003 MHz K-split, two output, 42 dB high gain forward, manual gain control, 14 dB internal slope, high gain return, full station 5-42 / 54-1003 MHz K-split, one output, 42 dB high gain forward, manual gain control, 14 dB internal slope, high gain return, full station 5-42 / 54-1003 MHz K-split, two output, 42 dB high gain forward, QAM ADU 711.00 MHz gain control, 14 dB internal slope, high gain return, full station 5-42 / 54-1003 MHz K-split, two output, 42 dB high gain forward, manual gain control, 14 dB internal slope, high gain return, 15A electronics module only (no housing) 5-42 / 54-1003 MHz K-split, 2-output, 42 dB high gain forward, manual gain control, 14 dB internal slope, no return, standard surge arrestor (no FTEC), full station 5-65 / 85-1003 MHz A-split, 2-output, high gain, manual gain control, standard 14 dB slope, high gain return, full station, RoHS compliant – AVAILABLE Q2 2007 5-55 / 70-1003 MHz A-split, 2-output, high gain, manual gain control, standard 14 dB slope, high gain return, full station, RoHS compliant – AVAILABLE Q2 2007
Starline Forward 1003 MHz equalizer (0 dB) -or­Starline Forward 1003 MHz equalizer (values 1 to 22 dB in 1 dB steps) -or­Starline Cable Simulator (values 1 to 10 dB in 1 dB steps)
values 0-12 dB in 1 dB steps for S-split (2 dB steps for all other frequency splits)
Splitter (1 GHz) to activate third output -or­Directional Coupler (1 GHz) to activate third output (8 dB) Directional Coupler (1 GHz) to activate third output (10 dB) Directional Coupler (1 GHz) to activate third output (12 dB)
Qty
Motorola
Part Number
per MB
721000-021-00
721000-006-00
535746-001-00
721000-010-00
721000-011-00
721000-012-00
721000-013-00
721000-014-00
721000-027-00
721000-015-00
535746-002-00
821000-001-00
821000-003-00
527333-001-00
1 527296-001 to -022 477888-001 to -010
478176-XXX-00 1
474011-XXX-00
529863-001-00 529864-001-00
9
(dual
output)
1
529864-002-00 529864-003-00
Motorola, Inc. 101 Tournament Drive Horsham, PA 19044
www.motorola.com/broadband
04.03.07 Rev 8
5
MOTOROLA, the Stylized M Logo, STARLINE, Mini-Bridger, and LIFELINE are registered in the US Patent & Trademark Office.
All other product or service names are the property of their respective owners.
©
Motorola, Inc. 2006. All rights reserved.
Specifications are subject to change without notice.
See next page for ordering guide/matrix.
1 GHz MB Ordering Guide
Key
2 1
MB
Key Key 100S H 100K 100A Key 100J X 100N
--
Bandpass Split
5 - 42 MHz / 54 - 1003 MHz
5 - 65 MHz / 85 - 1003 MHz
5 - 55 MHz / 70 - 1003 MHz
5 - 85 MHz / 104 - 1003 MHz
RF Configuration
Two-port
One-port
Key
H
E-GaAs (High Output w/ 42 dB Gain)
Key
XKey AF
QE15
S T
Gain
Level Control
None
ADU - 499.25/S
QADU - 609.00/S
QADU - 711.00/S
TDU
14 dB (Fmin - 1003 MHz)
Housing
Standard (Full Station)
Electronics only (15 amp)
Return Gain
High (20 dB)5 - 40 MHz / 52 - 1003 MHz
Station Slope
Key: Future options (not available today)
Notes:
1) Not all combinations in the ordering guide are available. This is a guide only. Please see “Ordering Information” (page 5) for available models.
2) FTECs are included in all models as standard, except for the “vanilla” models, MB2-100*H, which contain the standard gas tube.
3) 20A fuses are included in all amplifiers as standard.
4) ICS and status monitor transponders will continue to be customer configurable options.
5) For RoHS models, add “-R” to end of model string.
Motorola, Inc. 101 Tournament Drive Horsham, PA 19044
www.motorola.com/broadband
04.03.07 Rev 8
6
MOTOROLA, the Stylized M Logo, STARLINE, Mini-Bridger, and LIFELINE are registered in the US Patent & Trademark Office.
All other product or service names are the property of their respective owners.
©
Motorola, Inc. 2006. All rights reserved.
Specifications are subject to change without notice.
Loading...