Indicates that incorrect handling may cause hazardous conditions, resulting in
death or severe injury.
CAUTION
Indicates that incorrect handling may cause hazardous conditions, resulting in
minor or moderate injury or property damage.
(Read these precautions before using this product.)
Before using this product, please read this manual and the relevant manuals carefully and pay full attention to safety to handle
the product correctly.
The precautions given in this manual are concerned with this product only. Refer to the MELSEC iQ-R Module Configuration
Manual for a description of the PLC system safety precautions.
In this manual, the safety precautions are classified into two levels: "WARNING" and "CAUTION".
Under some circumstances, failure to observe the precautions given under "CAUTION" may lead to serious
consequences.
Observe the precautions of both levels because they are important for personal and system safety.
Make sure that the end users read this manual and then keep the manual in a safe place for future reference.
[Design Precautions]
WARNING
● Configure safety circuits external to the programmable controller to ensure that the entire system
operates safely even when a fault occurs in the external power supply or the programmable controller.
Failure to do so may result in an accident due to an incorrect output or malfunction.
(1) Emergency stop circuits, protection circuits, and protective interlock circuits for conflicting
operations (such as forward/reverse rotations or upper/lower limit positioning) must be configured
external to the programmable controller.
(2) When the programmable controller detects an abnormal condition, it stops the operation and all
outputs are:
• Turned off if the overcurrent or overvoltage protection of the power supply module is activated.
• Held or turned off according to the parameter setting if the self-diagnostic function of the CPU
module detects an error such as a watchdog timer error.
(3) All outputs may be turned on if an error occurs in a part, such as an I/O control part, where the
CPU module cannot detect any error. To ensure safety operation in such a case, provide a safety
mechanism or a fail-safe circuit external to the programmable controller. For a fail-safe circuit
example, refer to "General Safety Requirements" in the MELSEC iQ-R Module Configuration
Manual.
(4) Outputs may remain on or off due to a failure of a component such as a relay and transistor in an
output circuit. Configure an external circuit for monitoring output signals that could cause a
serious accident.
● In an output circuit, when a load current exceeding the rated current or an overcurrent caused by a
load short-circuit flows for a long time, it may cause smoke and fire. To prevent this, configure an
external safety circuit, such as a fuse.
● Configure a circuit so that the programmable controller is turned on first and then the external power
supply. If the external power supply is turned on first, an accident may occur due to an incorrect output
or malfunction.
● For the operating status of each station after a communication failure, refer to manuals relevant to the
network. Incorrect output or malfunction due to a communication failure may result in an accident.
1
[Design Precautions]
WARNING
● When connecting an external device with a CPU module or intelligent function module to modify data
of a running programmable controller, configure an interlock circuit in the program to ensure that the
entire system will always operate safely. For other forms of control (such as program modification,
parameter change, forced output, or operating status change) of a running programmable controller,
read the relevant manuals carefully and ensure that the operation is safe before proceeding. Improper
operation may damage machines or cause accidents.
● Especially, when a remote programmable controller is controlled by an external device, immediate
action cannot be taken if a problem occurs in the programmable controller due to a communication
failure. To prevent this, configure an interlock circuit in the program, and determine corrective actions
to be taken between the external device and CPU module in case of a communication failure.
● Do not write any data to the "system area" and "write-protect area" of the buffer memory in the
module. Also, do not use any "use prohibited" signals as an output signal from the CPU module to
each module. Doing so may cause malfunction of the programmable controller system. For the
"system area", "write-protect area", and the "use prohibited" signals, refer to the user's manual for the
module used.
● If a communication cable is disconnected, the network may be unstable, resulting in a communication
failure of multiple stations. Configure an interlock circuit in the program to ensure that the entire
system will always operate safely even if communications fail. Failure to do so may result in an
accident due to an incorrect output or malfunction.
● To maintain the safety of the programmable controller system against unauthorized access from
external devices via the network, take appropriate measures. To maintain the safety against
unauthorized access via the Internet, take measures such as installing a firewall.
● Configure safety circuits external to the programmable controller to ensure that the entire system
operates safely even when a fault occurs in the external power supply or the programmable controller.
Failure to do so may result in an accident due to an incorrect output or malfunction.
(1) Machine home position return is controlled by two kinds of data: a home position return direction
and a home position return speed. Deceleration starts when the proximity dog signal turns on. If
an incorrect home position return direction is set, motion control may continue without
deceleration. To prevent machine damage caused by this, configure an interlock circuit external to
the programmable controller.
(2) When the module detects an error, the motion slows down and stops or the motion rapidly stops,
depending on the stop group setting in parameter. Set the parameter to meet the specifications of
a positioning control system. In addition, set the home position return parameter and positioning
data within the specified setting range.
(3) Outputs may remain on or off, or become undefined due to a failure of a component such as an
insulation element and transistor in an output circuit, where the module cannot detect any error. In
a system that the incorrect output could cause a serious accident, configure an external circuit for
monitoring output signals.
● If safety standards (ex., robot safety rules, etc.,) apply to the system using the module, servo amplifier
and servomotor, make sure that the safety standards are satisfied.
● Construct a safety circuit externally of the module or servo amplifier if the abnormal operation of the
module or servo amplifier differs from the safety directive operation in the system.
2
[Design Precautions]
CAUTION
● Do not install the control lines or communication cables together with the main circuit lines or power
cables. Keep a distance of 100 mm or more between them. Failure to do so may result in malfunction
due to noise.
● During control of an inductive load such as a lamp, heater, or solenoid valve, a large current
(approximately ten times greater than normal) may flow when the output is turned from off to on.
Therefore, use a module that has a sufficient current rating.
● After the CPU module is powered on or is reset, the time taken to enter the RUN status varies
depending on the system configuration, parameter settings, and/or program size. Design circuits so
that the entire system will always operate safely, regardless of the time.
● Do not power off the programmable controller or reset the CPU module while the settings are being
written. Doing so will make the data in the flash ROM and SD memory card undefined. The values
need to be set in the buffer memory and written to the flash ROM and SD memory card again. Doing
so also may cause malfunction or failure of the module.
● When changing the operating status of the CPU module from external devices (such as the remote
RUN/STOP functions), select "Do Not Open by Program" for "Opening Method" of "Module
Parameter". If "Open by Program" is selected, an execution of the remote STOP function causes the
communication line to close. Consequently, the CPU module cannot reopen the line, and external
devices cannot execute the remote RUN function.
[Installation Precautions]
WARNING
● Shut off the external power supply (all phases) used in the system before mounting or removing the
module. Failure to do so may result in electric shock or cause the module to fail or malfunction.
3
[Installation Precautions]
CAUTION
● Use the programmable controller in an environment that meets the general specifications in the Safety
Guidelines included with the base unit. Failure to do so may result in electric shock, fire, malfunction,
or damage to or deterioration of the product.
● To mount a module, place the concave part(s) located at the bottom onto the guide(s) of the base unit,
and push in the module until the hook(s) located at the top snaps into place. Incorrect interconnection
may cause malfunction, failure, or drop of the module.
● To mount a module with no module fixing hook, place the concave part(s) located at the bottom onto
the guide(s) of the base unit, push in the module, and fix it with screw(s). Incorrect interconnection
may cause malfunction, failure, or drop of the module.
● When using the programmable controller in an environment of frequent vibrations, fix the module with
a screw.
● Tighten the screws within the specified torque range. Undertightening can cause drop of the screw,
short circuit, or malfunction. Overtightening can damage the screw and/or module, resulting in drop,
short circuit, or malfunction.
● When using an extension cable, connect it to the extension cable connector of the base unit securely.
Check the connection for looseness. Poor contact may cause malfunction.
● When using an SD memory card, fully insert it into the SD memory card slot. Check that it is inserted
completely. Poor contact may cause malfunction.
● Securely insert an extended SRAM cassette into the cassette connector of the CPU module. After
insertion, close the cassette cover and check that the cassette is inserted completely. Poor contact
may cause malfunction.
● Do not directly touch any conductive parts and electronic components of the module, SD memory
card, extended SRAM cassette, or connector. Doing so can cause malfunction or failure of the
module.
[Wiring Precautions]
WARNING
● Shut off the external power supply (all phases) used in the system before installation and wiring.
Failure to do so may result in electric shock or cause the module to fail or malfunction.
● After installation and wiring, attach a blank cover module (RG60) to each empty slot and an included
extension connector protective cover to the unused extension cable connector before powering on the
system for operation. Failure to do so may result in electric shock.
4
[Wiring Precautions]
CAUTION
● Individually ground the FG and LG terminals of the programmable controller with a ground resistance
of 100 ohms or less. Failure to do so may result in electric shock or malfunction.
● Use a solderless terminal with an insulation sleeve for terminal block wiring. Note that up to two
solderless terminals can be connected per terminal block.
● Use applicable solderless terminals and tighten them within the specified torque range. If any spade
solderless terminal is used, it may be disconnected when the terminal screw comes loose, resulting in
failure.
● Check the rated voltage and signal layout before wiring to the module, and connect the cables
correctly. Connecting a power supply with a different voltage rating or incorrect wiring may cause fire
or failure.
● Connectors for external devices must be crimped or pressed with the tool specified by the
manufacturer, or must be correctly soldered. Incomplete connections may cause short circuit, fire, or
malfunction.
● Securely connect the connector to the module. Poor contact may cause malfunction.
● Do not install the control lines or communication cables together with the main circuit lines or power
cables. Keep a distance of 100 mm or more between them. Failure to do so may result in malfunction
due to noise.
● When an overcurrent caused by an error of an external device or a failure of a module flows for a long
time, it may cause smoke and fire. To prevent this, configure an external safety circuit, such as a fuse.
● Place the cables in a duct or clamp them. If not, dangling cable may swing or inadvertently be pulled,
resulting in damage to the module or cables or malfunction due to poor contact. Do not clamp the
extension cables with the jacket stripped. Doing so may change the characteristics of the cables,
resulting in malfunction.
● When disconnecting the communication cable or power cable from the module, do not pull the cable
by the cable part. For the cable connected to the terminal block, loosen the terminal screws. Pulling
the cable connected to the module may result in malfunction or damage to the module or cable.
● Check the interface type and correctly connect the cable. Incorrect wiring (connecting the cable to an
incorrect interface) may cause failure of the module and external device.
● Tighten the terminal screws or connector screws within the specified torque range. Undertightening
can cause drop of the screw, short circuit, fire, or malfunction. Overtightening can damage the screw
and/or module, resulting in drop, short circuit, fire, or malfunction.
● Tighten the terminal block mounting screws, terminal screws, and module fixing screws within each
specified torque range. Undertightening of the terminal block mounting screws and terminal screws
can cause short circuit, fire, or malfunction. Overtightening of them can damage the screw and/or
module, resulting in drop, short circuit, or malfunction. Undertightening of the module fixing screws
can cause drop of the screw. Overtightening of them can damage the screw and/or module, resulting
in drop.
● When disconnecting the cable from the module, do not pull the cable by the cable part. For the cable
with connector, hold the connector part of the cable. For the cable connected to the terminal block,
loosen the terminal screw. Pulling the cable connected to the module may result in malfunction or
damage to the module or cable.
5
[Wiring Precautions]
CAUTION
● Prevent foreign matter such as dust or wire chips from entering the module. Such foreign matter can
cause a fire, failure, or malfunction.
● A protective film is attached to the top of the module to prevent foreign matter, such as wire chips,
from entering the module during wiring. Do not remove the film during wiring. Remove it for heat
dissipation before system operation.
● Programmable controllers must be installed in control panels. Connect the main power supply to the
power supply module in the control panel through a relay terminal block. Wiring and replacement of a
power supply module must be performed by qualified maintenance personnel with knowledge of
protection against electric shock. For wiring, refer to the MELSEC iQ-R Module Configuration Manual.
● For Ethernet cables to be used in the system, select the ones that meet the specifications in the user's
manual for the module used. If not, normal data transmission is not guaranteed.
[Startup and Maintenance Precautions]
WARNING
● Do not touch any terminal while power is on. Doing so will cause electric shock or malfunction.
● Correctly connect the battery connector. Do not charge, disassemble, heat, short-circuit, solder, or
throw the battery into the fire. Also, do not expose it to liquid or strong shock. Doing so will cause the
battery to produce heat, explode, ignite, or leak, resulting in injury and fire.
● Shut off the external power supply (all phases) used in the system before cleaning the module or
retightening the terminal screws, connector screws, or module fixing screws. Failure to do so may
result in electric shock.
6
[Startup and Maintenance Precautions]
CAUTION
● When connecting an external device with a CPU module or intelligent function module to modify data
of a running programmable controller, configure an interlock circuit in the program to ensure that the
entire system will always operate safely. For other forms of control (such as program modification,
parameter change, forced output, or operating status change) of a running programmable controller,
read the relevant manuals carefully and ensure that the operation is safe before proceeding. Improper
operation may damage machines or cause accidents.
● Especially, when a remote programmable controller is controlled by an external device, immediate
action cannot be taken if a problem occurs in the programmable controller due to a communication
failure. To prevent this, configure an interlock circuit in the program, and determine corrective actions
to be taken between the external device and CPU module in case of a communication failure.
● Do not disassemble or modify the modules. Doing so may cause failure, malfunction, injury, or a fire.
● Use any radio communication device such as a cellular phone or PHS (Personal Handy-phone
System) more than 25 cm away in all directions from the programmable controller. Failure to do so
may cause malfunction.
● Shut off the external power supply (all phases) used in the system before mounting or removing the
module. Failure to do so may cause the module to fail or malfunction.
● Tighten the screws within the specified torque range. Undertightening can cause drop of the
component or wire, short circuit, or malfunction. Overtightening can damage the screw and/or module,
resulting in drop, short circuit, or malfunction.
● After the first use of the product, do not mount/remove the module to/from the base unit, and the
terminal block to/from the module, and do not insert/remove the extended SRAM cassette to/from the
CPU module more than 50 times (IEC 61131-2 compliant) respectively. Exceeding the limit may cause
malfunction.
● After the first use of the product, do not insert/remove the SD memory card to/from the CPU module
more than 500 times. Exceeding the limit may cause malfunction.
● Do not touch the metal terminals on the back side of the SD memory card. Doing so may cause
malfunction or failure of the module.
● Do not touch the integrated circuits on the circuit board of an extended SRAM cassette. Doing so may
cause malfunction or failure of the module.
● Do not drop or apply shock to the battery to be installed in the module. Doing so may damage the
battery, causing the battery fluid to leak inside the battery. If the battery is dropped or any shock is
applied to it, dispose of it without using.
● Startup and maintenance of a control panel must be performed by qualified maintenance personnel
with knowledge of protection against electric shock. Lock the control panel so that only qualified
maintenance personnel can operate it.
● Before handling the module, touch a conducting object such as a grounded metal to discharge the
static electricity from the human body. Failure to do so may cause the module to fail or malfunction.
● Before testing the operation, set a low speed value for the speed limit parameter so that the operation
can be stopped immediately upon occurrence of a hazardous condition.
● Confirm and adjust the program and each parameter before operation. Unpredictable movements
may occur depending on the machine.
● When using the absolute position system function, on starting up, and when the module or absolute
position motor has been replaced, always perform a home position return.
7
[Startup and Maintenance Precautions]
CAUTION
● Before starting the operation, confirm the brake function.
● Do not perform a megger test (insulation resistance measurement) during inspection.
● After maintenance and inspections are completed, confirm that the position detection of the absolute
position detection function is correct.
● Lock the control panel and prevent access to those who are not certified to handle or install electric
equipment.
[Operating Precautions]
CAUTION
● When changing data and operating status, and modifying program of the running programmable
controller from an external device such as a personal computer connected to an intelligent function
module, read relevant manuals carefully and ensure the safety before operation. Incorrect change or
modification may cause system malfunction, damage to the machines, or accidents.
● Do not power off the programmable controller or reset the CPU module while the setting values in the
buffer memory are being written to the flash ROM in the module. Doing so will make the data in the
flash ROM and SD memory card undefined. The values need to be set in the buffer memory and
written to the flash ROM and SD memory card again. Doing so also may cause malfunction or failure
of the module.
● Note that when the reference axis speed is specified for interpolation operation, the speed of the
partner axis (2nd, 3rd, or 4th axis) may exceed the speed limit value.
● Do not go near the machine during test operations or during operations such as teaching. Doing so
may lead to injuries.
[Disposal Precautions]
CAUTION
● When disposing of this product, treat it as industrial waste.
● When disposing of batteries, separate them from other wastes according to the local regulations. For
details on battery regulations in EU member states, refer to the MELSEC iQ-R Module Configuration
Manual.
[Transportation Precautions]
CAUTION
● When transporting lithium batteries, follow the transportation regulations. For details on the regulated
models, refer to the MELSEC iQ-R Module Configuration Manual.
● The halogens (such as fluorine, chlorine, bromine, and iodine), which are contained in a fumigant
used for disinfection and pest control of wood packaging materials, may cause failure of the product.
Prevent the entry of fumigant residues into the product or consider other methods (such as heat
treatment) instead of fumigation. The disinfection and pest control measures must be applied to
unprocessed raw wood.
8
CONDITIONS OF USE FOR THE PRODUCT
(1) Mitsubishi programmable controller ("the PRODUCT") shall be used in conditions;
i) where any problem, fault or failure occurring in the PRODUCT, if any, shall not lead to any major or serious accident;
and
ii) where the backup and fail-safe function are systematically or automatically provided outside of the PRODUCT for the
case of any problem, fault or failure occurring in the PRODUCT.
(2) The PRODUCT has been designed and manufactured for the purpose of being used in general industries.
MITSUBISHI SHALL HAVE NO RESPONSIBILITY OR LIABILITY (INCLUDING, BUT NOT LIMITED TO ANY AND ALL
RESPONSIBILITY OR LIABILITY BASED ON CONTRACT, WARRANTY, TORT, PRODUCT LIABILITY) FOR ANY
INJURY OR DEATH TO PERSONS OR LOSS OR DAMAGE TO PROPERTY CAUSED BY the PRODUCT THAT ARE
OPERATED OR USED IN APPLICATION NOT INTENDED OR EXCLUDED BY INSTRUCTIONS, PRECAUTIONS, OR
WARNING CONTAINED IN MITSUBISHI'S USER, INSTRUCTION AND/OR SAFETY MANUALS, TECHNICAL
BULLETINS AND GUIDELINES FOR the PRODUCT.
("Prohibited Application")
Prohibited Applications include, but not limited to, the use of the PRODUCT in;
• Nuclear Power Plants and any other power plants operated by Power companies, and/or any other cases in which the
public could be affected if any problem or fault occurs in the PRODUCT.
• Railway companies or Public service purposes, and/or any other cases in which establishment of a special quality
assurance system is required by the Purchaser or End User.
• Aircraft or Aerospace, Medical applications, Train equipment, transport equipment such as Elevator and Escalator,
Incineration and Fuel devices, Vehicles, Manned transportation, Equipment for Recreation and Amusement, and
Safety devices, handling of Nuclear or Hazardous Materials or Chemicals, Mining and Drilling, and/or other
applications where there is a significant risk of injury to the public or property.
Notwithstanding the above, restrictions Mitsubishi may in its sole discretion, authorize use of the PRODUCT in one or
more of the Prohibited Applications, provided that the usage of the PRODUCT is limited only for the specific
applications agreed to by Mitsubishi and provided further that no special quality assurance or fail-safe, redundant or
other safety features which exceed the general specifications of the PRODUCTs are required. For details, please
contact the Mitsubishi representative in your region.
9
INTRODUCTION
Thank you for purchasing the Mitsubishi Electric MELSEC iQ-R series programmable controllers.
This manual describes the functions, programming, and troubleshooting of the relevant products listed below. Before using
this product, please read this manual and the relevant manuals carefully and develop familiarity with the functions and
performance of the MELSEC iQ-R series programmable controller to handle the product correctly.
When applying the program examples provided in this manual to an actual system, ensure the applicability and confirm that it
will not cause system control problems.
Please make sure that the end users read this manual.
Relevant products
RD77GF4, RD77GF8, RD77GF16, RD77GF32
COMPLIANCE WITH EMC AND LOW VOLTAGE
DIRECTIVES
Method of ensuring compliance
To ensure that Mitsubishi programmable controllers maintain EMC and Low Voltage Directives when incorporated into other
machinery or equipment, certain measures may be necessary. Please refer to one of the following manuals.
MELSEC iQ-R Module Configuration Manual
Safety Guidelines (This manual is included with the base unit.)
The CE mark on the side of the programmable controller indicates compliance with EMC and Low Voltage Directives.
Additional measures
To ensure that this product maintains EMC and Low Voltage Directives, please refer to one of the following manuals.
MELSEC iQ-R Module Configuration Manual
Safety Guidelines (This manual is included with the base unit.)
This manual does not include information on the module function blocks.
For details, refer to the Function Block Reference for the module used.
e-Manual refers to the Mitsubishi Electric FA electronic book manuals that can be browsed using a dedicated
tool.
e-Manual has the following features:
• Required information can be cross-searched in multiple manuals.
• Other manuals can be accessed from the links in the manual.
• The hardware specifications of each part can be found from the product figures.
• Pages that users often browse can be bookmarked.
• Sample programs can be copied to an engineering tool.
Functions, parameter settings, troubleshooting, and buffer
memory of CC-Link IE Field Network
Specifications, procedures before operation, system
configuration, wiring, and operation examples of the Simple
Motion module
Functions, input/output signals, buffer memory, parameter
settings, programming, and troubleshooting of the Simple
Motion module
Functions and programming for the synchronous control of the
Simple Motion module
Print book
e-Manual
PDF
Print book
e-Manual
PDF
Print book
e-Manual
PDF
Print book
e-Manual
PDF
13
TERMS
Unless otherwise specified, this manual uses the following terms.
TermDescription
Baton passA token to send data over a network
Buffer memoryA memory in an intelligent function module, where data (such as setting values and monitoring values) are
stored. When using the CPU module, the memory is indicated for storing data (such as setting values and
monitored values) of the Ethernet function and data used for data communication of the multiple CPU function.
CC-Link IE Controller Network-equipped
module
CC-Link IE Field NetworkA high-speed and large-capacity open field network that is based on Ethernet (1000BASE-T)
Control CPUA CPU module that controls connected I/O modules and intelligent function modules. In a multiple CPU system,
CPU moduleThe abbreviation for the MELSEC iQ-R series CPU module
CPU module (built-in Ethernet port part)A built-in Ethernet port part of the CPU module (CPU part for the RnENCPU) ( MELSEC iQ-R Ethernet/CC-
Cyclic transmissionA function by which data are periodically exchanged among stations on the network using link devices
Data linkA generic term for cyclic transmission and transient transmission
Dedicated instructionAn instruction for using functions of the module
DeviceA device (X, Y, M, D, or others) in a CPU module
DisconnectionA process of stopping data link if a data link error occurs
Engineering toolA generic term for GX Works3 and MR Configurator2
Ethernet adapter moduleThe abbreviation for the NZ2GF-ETB CC-Link IE Field Network Ethernet adapter module
Ethernet deviceA generic term for the devices supporting IP communication (such as personal computers)
Ethernet-equipped moduleA generic term for the following modules when the Ethernet function is used
Global labelA label that is enabled for all program data when creating multiple program data in the project. There are two
Head moduleThe abbreviation for the LJ72GF15-T2 CC-Link IE Field Network head module
Intelligent device stationA station that exchanges I/O signals (bit data) and I/O data (word data) with another station by cyclic
Intelligent function moduleA MELSEC iQ-R series module that has functions other than input and output, such as an A/D converter module
LabelA label that represents a device in a given character string
Link deviceA device (RX, RY, RWr, or RWw) in a module on CC-Link IE Field Network
Link refreshAutomatic data transfer between a link device of the Simple Motion module and a device in a CPU module
Link scan (link scan time)Time required for all the stations on the network to transmit data. The link scan time depends on data volume and
Link special register (SW)Word data that indicates the operating status and data link status of a module on CC-Link IE Field Network
Link special relay (SB)Bit data that indicates the operating status and data link status of a module on CC-Link IE Field Network
Local stationA station that performs cyclic transmission and transient transmission with the master station and other local
Master operating stationA station that controls the entire network in the network where a master station and submaster station are
Master stationA station that controls the entire network. This station can perform cyclic transmission and transient transmission
Master/local moduleA generic term for the RJ71GF11-T2 CC-Link IE Field Network master/local module and the following modules
Module labelA label that represents one of memory areas (I/O signals and buffer memory areas) specific to each module in a
A generic term for the RJ71GP21-SX CC-Link IE Controller Network module and the following modules when the
CC-Link IE Controller Network function is used:
• RJ71EN71
• RnENCPU
there are multiple CPU modules and each connected module can be controlled by a different CPU module.
Link IE User's Manual (Startup))
• RJ71EN71
• CPU module
types of global labels: module label that is automatically generated by GX Works3 and label that can be created
for the any of the specified devices.
transmission. This station responds to a transient transmission request from another station and also issues a
transient transmission request to another station.
and D/A converter module
the number of transient transmission requests.
stations
connected. Only one master station can be used in a network.
with all stations. Only one master station can be used in a network.
when the CC-Link IE Field Network function is used:
• RJ71EN71
• RnENCPU
given character string. GX Works3 automatically generates this label, which can be used as a global label.
14
Ter mDescription
Network moduleA generic term for the following modules:
RASThe abbreviation for Reliability, Availability, and Serviceability. This term refers to usability of automated
READA generic term for the JP.READ and GP.READ
RECVA generic term for the JP.RECV and GP.RECV
RECVSA generic term for the G.RECVS and Z.RECVS
Relay stationA station that includes two or more network modules. Data are passed through this station to stations on other
REMFRA generic term for the JP.REMFR and ZP.REMFR
Remote device stationA station that exchanges I/O signals (bit data) and I/O data (word data) with another station by cyclic
Remote head moduleThe abbreviation for the RJ72GF15-T2 CC-Link IE Field Network remote head module
Remote I/O stationA station that exchanges I/O signals (bit data) with the master station by cyclic transmission
Remote input (RX)Bit data input from a slave station to the master station (For some areas in a local station, data are input in the
Remote output (RY)Bit data output from the master station to a slave station (For some areas in a local station, data are output in the
Remote register (RWr)Word data input from a slave station to the master station (For some areas in a local station, data are input in the
Remote register (RWw)Word data output from the master station to a slave station (For some areas in a local station, data are output in
REMTOA generic term for the JP.REMTO and ZP.REMTO
REQA generic term for the J.REQ, JP.REQ, G.REQ, and GP.REQ
Reserved stationA station reserved for future use. This station is not actually connected, but counted as a connected station.
ReturnA process of restarting data link when a station recovers from an error
RIRDA generic term for the J.RIRD, JP.RIRD, G.RIRD, and GP.RIRD
RIWTA generic term for the J.RIWT, JP.RIWT, G.RIWT, and GP.RIWT
RnENCPUA generic term for the R04ENCPU, R08ENCPU, R16ENCPU, R32ENCPU, and R120ENCPU
RnENCPU (CPU part)The left side (CPU part) of the RnENCPU (MELSEC iQ-R Ethernet/CC-Link IE User's Manual (Startup))
RnENCPU (network part)The right side (network part) of the RnENCPU (MELSEC iQ-R Ethernet/CC-Link IE User's Manual (Startup))
RoutingA process of selecting paths for communication with other networks. There are two types of routing: dynamic
Safety communicationsA function to exchange safety data between safety stations on the same network
Safety connectionA connection established for safety communications
Safety CPUA generic term for the R08SFCPU, R16SFCPU, R32SFCPU, and R120SFCPU
Safety dataData exchanged through safety communications
Safety deviceA device that can be used in safety programs
Safety function moduleAnother term for the R6SFM
Safety stationA generic term for a station that performs safety communications and standard communications
Seamless communicationCommunication that allows users to access a different kind of networks without having to consider the
SENDA generic term for the JP.SEND and GP.SEND
Servo amplifierA generic term for a drive unit
Simple Motion moduleThe abbreviation for the MELSEC iQ-R series Simple Motion module (compatible with CC-Link IE Field Network)
Slave stationA generic term for a local station, remote I/O station, remote device station, and intelligent device station
SREADA generic term for the JP.SREAD and GP.SREAD
Submaster operating stationA station that monitors the status of a master operating station in the network where a master station and
• Ethernet interface module
• CC-Link IE Controller Network module
• Module on CC-Link IE Field Network
• MELSECNET/H network module
• MELSECNET/10 network module
• RnENCPU (network part)
equipment.
networks
transmission. This station responds to a transient transmission request from another station.
opposite direction.)
opposite direction.)
opposite direction.)
the opposite direction.)
routing that auto-selects the communication routes, and static routing where communication routes are arbitrarily
set.
differences as if data were exchanged within one single network
Unless specified in particular, indicates the motor driver unit of the sequential command method which is
controlled by the Simple Motion module (belonging to own station).
• RD77GF
submaster station are connected. Only one master station can be used in a network.
15
TermDescription
Submaster stationA station that serves as a master station to control the entire network if the master station is disconnected. Only
SWRITEA generic term for the JP.SWRITE and GP.SWRITE
System switchingA function which switches the systems between the control system and the standby system to continue operation
Transient transmissionA function of communication with another station, which is used when requested by a dedicated instruction or the
WRITEA generic term for the JP.WRITE and GP.WRITE
one master station can be used in a network.
of the redundant system when a failure or an error occurs in the control system
engineering tool
16
1FUNCTIONS
1.1Fixed Cycle Communication
The communication cycle of the Simple Motion module is fixed cycle. The communication is performed with slave modules in
a cycle set in the inter-module synchronization cycle setting.
Refer to the following for details.
MELSEC iQ-R Inter-Module Synchronization Function Reference Manual
1.2CC-Link IE Field Network Synchronous
Communication Function
A slave module which supports the CC-Link IE Field Network synchronous communication function operates synchronously
with the inter-module synchronization cycle of the Simple Motion module (the communication cycle of CC-Link IE Field
Network). Therefore, the operation timing between the Simple Motion module and each slave module can be synchronized.
A slave module which does not support the CC-Link IE Field Network synchronous communication function is also
connectable. However, the operation is not synchronized with the inter-module synchronization cycle of the Simple Motion
module. Therefore, the operation timing of the slave module is not synchronized with the Simple Motion module.
Refer to the following for details.
MELSEC iQ-R Inter-Module Synchronization Function Reference Manual
1
1 FUNCTIONS
1.1 Fixed Cycle Communication
17
1.3Cyclic Transmission
RX, RWr
*1
RX, RWr
*1
RX, RWr
END
RY, RWw
*1
RY, RWw
*1
RY, RWw
END
RX, RWr
M0
Y
Ò
Ó
Ø
×
×
×
Ô
Ô
Ô
Ö
Õ
Slave station
Station No.1
Slave station
Station No.2
Slave station
Station No.3
Station
No.1
Station
No.2
Station
No.3
External device
External device
CPU module
Device
Device
Station No.1
Station No.2
Station No.3
Station No.0
Area where data is sent to
other stations
Station
No.1
Station
No.2
Station
No.3
Station No.1
Station No.2
Station No.3
Link
refresh
Link
refresh
Link
scan
Inter-module
synchronization
cycle
Inter-module
synchronization
cycle
Master station
(Simple
Motion
module)
RY, RWw
This function allows data to be periodically exchanged among stations on the same network using link devices.
Data flow and link device assignment
Master station and slave stations (except for local stations)
One-to-one communication is possible between the master and slave stations. The status data of the link devices (RY, RWw)
of the master station is output to the external device of the slave station, and the input status information from the external
device of the slave station is stored in the link devices (RX, RWr) of the master station.
18
*1 There is no RX or RY depending on the slave module.
• Output from the master station
The device of the CPU module turns on.
The status data of the device of the CPU module are stored in the link devices (RY, RWw) of the master station by link refresh.
The status data of the link devices (RY, RWw) of the master station are stored in the link devices (RY, RWw) of each slave station by link scan.
The status data of the link devices (RY, RWw) of the slave station are output to the external device.
• Input from the slave station
The status data of the external device are stored in the link devices (RX, RWr) of the slave station.
The status data of the link devices (RX, RWr) of the slave station are stored in the link devices (RX, RWr) of the master station by link scan.
The status data of the link devices (RX, RWr) of the master station are stored in the devices of the CPU module by link refresh.
1 FUNCTIONS
1.3 Cyclic Transmission
Master station and local stations
M0
END
END
M0
END
END
Ò
Ó
Ô
Õ
×
Ö
Ù
Ø
Y
Y
RX, RWr
RY, RWw
RX, RWr
RY, RWw
RX, RWr
RY, RWw
RX, RWr
RY, RWw
Inter-module
synchronization
cycle
Inter-module
synchronization
cycle
Local station
Station No.1
Local station
Station No.2
Local station
Station No.3Station No.0
Area where data is sent to
other stations
Range of the
station No.1
sending data
Range of the
station No.2
sending data
Range of the
station No.3
sending data
Range of the
sending data to
the station No.1
Range of the
sending data to
the station No.2
Range of the
sending data to
the station No.3
Sequence
scan
Sequence
scan
Station
No.1
Station
No.2
Station
No.3
Station
No.1
Station
No.2
Station
No.3
Station
No.2
Station
No.3
Station
No.1
Station
No.2
Station
No.3
Station
No.1
Station
No.3
Station
No.1
Station
No.2
Station
No.1
Station
No.2
Station
No.3
CPU moduleCPU module
Device
Device
Device
Device
Link
refresh
Link
refresh
Link
refresh
Link
refresh
Link
scan
Master
station
(Simple
Motion
module)
Data can be written into the send range of the link devices (RY, RWw) of each station and can be sent to any station on the
same network. The status data of the link devices (RY, RWw) of the master station are stored in the link devices (RX, RWr) of
each local station. The status data of the link devices (RY, RWw) of local stations are stored in the link devices (RX, RWr) of
the master station and the link devices (RY, RWw) of other local stations.
1
• Output from the master station
The device of the CPU module turns on.
The status data of the device of the CPU module are stored in the link devices (RY, RWw) of the master station by link refresh.
The status data of the link devices (RY, RWw) of the master station are stored in the link devices (RX, RWr) of the local station by link scan.
The status data of the link devices (RX, RWr) of the local station are stored in the devices of the CPU module.
• Input from the local station
The device of the CPU module turns on.
The device status data of the CPU module are stored in the own station send range of the link devices (RY, RWw).
The status data of the link devices (RY, RWw) of the local station are stored in the link devices (RX, RWr) of the master station by link scan.
The status data of the link devices (RX, RWr) of the master station are stored in the devices of the CPU module by link refresh.
1.3 Cyclic Transmission
1 FUNCTIONS
19
Coexistence of local stations and the other slave stations (other than local stations)
RX, RWr
RY, RWw
*1
RX, RWr
*1
RY, RWw
*1
RX, RWr
RY, RWw
RX, RWr
RY, RWw
Master
station
(Simple
Motion
module)
Slave station
Station No.1
Slave station
Station No.2Station No.3Station No.0
Local station
Area where data is sent to
other stations
Range of the
station No.1
sending data
Range of the
station No.2
sending data
Range of the
sending data to
the station No.1
Range of the
sending data to
the station No.2
Range of the
sending data to
the station No.3
CPU module
Station
No.1
Station
No.2
Station
No.1
Station
No.2
Station
No.1
Station
No.2
Station
No.3
Station
No.1
Station
No.2
Station
No.3
Device
Device
*1
Range of the
station No.3
sending data
The data of all slave stations are also stored in the local stations in the same way as the master station.
*1 There is no RX or RY depending on the slave module.
Setting method
The link devices can be assigned in "Network Configuration Settings" under "Basic Settings". (Page 67 Network
Configuration Settings)
The link refresh is assigned in "Refresh Settings" under "Basic Settings". (Page 70 Refresh Settings)
20
1 FUNCTIONS
1.3 Cyclic Transmission
Link refresh
RX
RY
RWr
RWw
CPU module
Device
Link refresh
Simple Motion module
Link device
(1)
(2)(3)
CPU module
Device
Simple Motion
module
Link device
Link refresh
Link refresh
Link refresh
Empty
Empty
This function automatically transfers data between the link devices of the Simple Motion module and the devices of the CPU
module.
Concept of the link refresh range (number of points)
The link refresh is performed to the area set in "Refresh Settings" under "Basic Settings" and also specified in "Network
Configuration Settings" under "Basic Settings".
(1) Range set in "Refresh Settings" under "Basic
Settings"
(2) Actual link refresh range
(3) Range set in "Network Configuration Settings"
under "Basic Settings"
1
Shortening the link refresh time and transmission delay time
The link refresh time and transmission delay time can be shortened by reducing the number of link refresh points to the CPU
module. The following methods can be used to reduce the number of the link refresh points.
• In "Refresh Settings" under "Basic Settings", set only the link devices used in the CPU module as the link refresh range.
(Page 70 Refresh Settings)
• Directly access infrequently used link devices from the program, and remove the corresponding settings from the link
refresh range. (Page 23 Direct access to link devices)
Setting method
The link refresh is assigned in "Refresh Settings" under "Basic Settings". (Page 70 Refresh Settings)
1 FUNCTIONS
1.3 Cyclic Transmission
21
Precautions
■Latched devices of the CPU module
If data in latched devices of the CPU module are cleared to zero on a program when the CPU module is powered off and on
or reset, the data may be output without being cleared to zero, depending on the timing of the link scan and link refresh. Take
the following actions not to output the data in the latched devices of the CPU module.
CPU module deviceHow to disable the device data
Latch relay (L), file register (R, ZR)Use the initial device value of the CPU module to clear the device to zero.
CPU module device within the latch rangeDelete all the latch range settings specified in "Latch Interval Operation
Setting" under "Device Latch Interval Setting" in "Memory/Device Setting" of
"CPU Parameter".
*1 For the initial device value setting of the CPU module, refer to the following.
GX Works3 Operating Manual
When the inter-module synchronization setting is set to "Not Use", the link device (RX/RY/RWr/RWw) of the
station whose network synchronous communication is set to "Synchronous" is not refreshed.
*1
22
1 FUNCTIONS
1.3 Cyclic Transmission
Direct access to link devices
Ex.
J
(1) (2)
__
\
RWw100 RWw100
RWr100 RWr100
RY1000
RY1000
RX1100RX1100
XYWRX
RWr RWw
RYRXRY
RWr RWw
Master stationSlave station
Network No.1
Simple Motion
module
Send
request
CPU moduleSlave station
Cyclic transmission
MOV K20 J1\W100
= J1\W2100 K300
J1\X1100
J1\Y1000
Actual I/O
This function directly accesses the link devices (RX, RY, RWr, RWw, SB, or SW) of the Simple Motion module from the
program. Specify a link device as the link direct device (J_\_) for direct access.
Specification method
Specify the network No. and the link device of the Simple Motion module for reading or writing.
(1) Network No.: 1 to 239
(2) Remote input (RX): X0 to X3FFF
Remote output (RY): Y0 to Y3FFF
Remote register (RWw): W0 to W1FFF
Remote register (RWr): W2000 to W3FFF
Link special relay (SB): SB0 to SB1FF
Link special register (SW): SW0 to SW1FF
1
1 FUNCTIONS
1.3 Cyclic Transmission
23
Readable and writable range
Ex.
(2)
(1)
(3)
Y
RY
CPU moduleSimple Motion module
This area is
writable.
Link refresh
Link refresh
RWw
20RWw100
W
W100
20
Simple Motion moduleCPU module
MOV K20 J1\W100
Link refresh
MOV K20 W100
Data can be read or written between the Simple Motion module and CPU module mounted on the same base unit.
■Read
All link devices of the Simple Motion module can be specified. (Page 23 Specification method)
■Write
The range that satisfies all of the following conditions can be specified.
• Area where data is sent to other stations and outside the link refresh range (Page 18 Data flow and link device
assignment)
• Within the link device range of the Simple Motion module (Page 23 Specification method)
The following shows the example.
(1) Out of the link refresh range
(2) Area where data is sent to other stations
(3) Area for receiving the data from other stations
When writing data to the area in the link refresh range, directly access the link device and write the same data
in the device of the CPU module.
• Bad example (Only direct access to the link refresh target)
Link refresh overwrites the value.
MOV K20 J1\W100
• Good example (In addition to direct access, writing the same data to the CPU module device)
The value written by direct access is reflected.
Simple Motion moduleCPU module
W
300W100
Link refresh
RWw
20300 RWw100
24
1 FUNCTIONS
1.3 Cyclic Transmission
Differences from link refresh
ItemAccess method
Link refreshDirect access
Number of steps1 step2 steps
Processing speed
Cyclic data integrity assuranceAvailableNot available
*1 For actual values, refer to the following.
MELSEC iQ-R Programming Manual (CPU Module Instructions, Standard Functions/Function Blocks)
*1
High speedLow speed
Shortening the link refresh time and transmission delay time
■Shortening the link refresh time
Remove infrequently used link devices from the link refresh range, and directly read or write the corresponding data using link
direct devices. This reduces the number of the link refresh points to the CPU module, resulting in a shorter link refresh time.
(Page 21 Link refresh)
■Shortening the transmission delay time
Because the link direct device allows direct reading or writing of data to the link devices of the Simple Motion module at the
time of the instruction execution, the transmission delay time can be shortened.
Link refresh is executed in END processing of the sequence scan of the CPU module.
Precautions
1
■Cyclic data integrity assurance
Direct access to link devices does not provide station-based block data assurance. Use 32-bit data assurance, or if cyclic data
of more than 32 bits needs to be assured, use interlock programs. (Page 26 Cyclic data integrity assurance)
■Mounting multiple modules of the same network No.
When multiple Simple Motion modules of the same network No. are mounted, the target of direct access is the module which
has the smallest slot No. in the base unit.
■Link direct device in a multiple CPU system
In a multiple CPU system, link direct devices cannot be used for the CC-Link IE Controller Network-equipped module
controlled by another CPU module.
1 FUNCTIONS
1.3 Cyclic Transmission
25
Cyclic data integrity assurance
0H
1H
2H
3H
4H
5H
6H
7H
RWr, RWw
2 words
(32 bits)
Simple Motion module
Device
CPU module
Link refresh
2 words
(32 bits)
2 words
(32 bits)
2 words
(32 bits)
2 words
(32 bits)
2 words
(32 bits)
2 words
(32 bits)
2 words
(32 bits)
This function assures the cyclic data integrity in units of 32 bits or station-based units.
: Assured, : Not assured
MethodDescriptionAvailability
Link refreshDirect access to
link devices
32-bit data assuranceAssures data in 32-bit units.
Station-based block data
assurance
Interlock programAssures data of more than 32 bits.
*1
Data is automatically assured by satisfying
assignment conditions of link devices.
Assures data in station-based units.
Data is assured by enabling the station-based
block data assurance in the parameter setting.
Data is assured by configuring interlocks on
programs.
*1 When the software version of the Simple Motion module is "Ver.01":
The set parameter is ignored in the Simple Motion module and operate as "Disable". Assure data using interlock programs as required.
When the software version of the Simple Motion module is "Ver.02" or later:
To enable data assurance in an asynchronous station, read/write data by direct access in the inter-module synchronous interrupt
program (I44) without using a link refresh.
When there is a remote device station in the network, use station-based block data assurance. If it is disabled,
the functions of the remote device station cannot be assured.
Access to buffer
memory
32-bit data assurance
The RWr and RWw data can be assured in 32-bit units.
■Data assurance at the time of direct access to link devices
When link refresh target devices are accessed, the integrity of 32-bit data can be assured by satisfying the following
conditions.
• The start device No. of RWr, RWw is multiples of 2.
• The number of points assigned to RWr, RWw is multiples of 2.
26
1 FUNCTIONS
1.3 Cyclic Transmission
■Data integrity assurance at the time of access to buffer memory
Precautions
0H
1H
2H
3H
4H
5H
6H
7H
2 words
(32 bits)
Buffer memory
Simple Motion module
2 words
(32 bits)
2 words
(32 bits)
2 words
(32 bits)
DMOV instruction
\
The integrity of 32-bit data can be assured by satisfying the following conditions.
• Access using the DMOV instruction
• The start address of the buffer memory is multiples of 2.
For data assurance of more than 32 bits, use station-based block data assurance or interlock programs.
Station-based block data assurance
Integrity of the cyclic data is assured for each station by handshake between the CPU module and Simple Motion module for
a link refresh.
1
• When the software version of the Simple Motion module is "Ver.01":
The set parameter is ignored in the Simple Motion module and operate as "Disable". Assure data using interlock programs
as required.
• When the software version of the Simple Motion module is "Ver.02" or later:
To enable data assurance in an asynchronous station, read/write data by direct access in the inter-module synchronous
interrupt program (I44) without using a link refresh. There are restrictions on the operation by the inter-module
synchronization setting, operation mode, and network synchronous communication.
<Inter-module synchronization valid>
Operation mode Network communication setting
SynchronousAsynchronous
High-speedEnableDisable
NormalEnableEnable
<Inter-module synchronization invalid>
Operation modeNetwork communication setting
SynchronousAsynchronous
High-speedDisableDisable
NormalDisableEnable
■Setting
Set station-based block data assurance under "Supplementary Cyclic Settings" in "Application Settings" of the master station.
(Page 74 Application Settings)
Once this setting is enabled on the master station, integrity of the data for all stations is assured for each station.
1 FUNCTIONS
1.3 Cyclic Transmission
27
■Access to link devices
Station
No.1
Station
No.2
Station
No.3
Station
No.4
Data
assurance
Data
assurance
Data
assurance
Data
assurance
Data
assurance
Data
assurance
Data
assurance
Data
assurance
Station
No.1
Station
No.2
Station
No.3
Station
No.4
Link device
Simple Motion module
Device
CPU module
Link refresh
Simple Motion module
Master/local module
Receiving stationSending station
Master station
(station No.0)
Local station
(station No.1)
SET Y1000
X1000
Y1000
RX0
RY0RY0
RWw0
RWr0
RWw0
RWr0
RX0
Y1000
W0
W1000
W0
W1000
X1000
X1000
Send
request
Send data (W)
CPU
module
Master
station
CPU
module
Local
station
Cyclic transmission
Link refresh
Receive data (W)
During a link refresh, data are assured for each station as shown below.
Interlock program
Data of more than 32 bits can be assured with the station-based block data assurance setting disabled. Use either of the
following methods.
• Interlock using X and Y
• Interlock using devices other than X and Y (when X, Y cannot be used as an interlock device)
■Example of interlock using X and Y
An example of sending data in W0 to W3 of the master station (station No.0) to W1000 to W1003 of the local station (station
No.1) is shown below. (X1000 and Y1000 are used for a handshake to the CPU module.)
• Data flow
28
1 FUNCTIONS
1.3 Cyclic Transmission