13. PARTS LIST ····················································29
···················15
··············4
•The contents of LD6 in Main functions of LED
(page 13) have been revised.
•The contents of LD5 and LD6 in
TROUBLESHOOTING ACCORDING TO
CHECK CODE (page 22) have been revised.
•Refer to other manual as for Indoor Units.
•Please void OC247 REVISED EDITION-B.
1
Rear
Right
Base
Front
Indoor unitOutdoor unit
Indoor
heat
exchanger
4•way
valve
Accumulator
Compressor
Outdoor
heat
exchanger
Capillary tubes
for heating
Capillary
tubes for
cooling
Liquid section
of piping
HIgh-pressure
liquid
refrigerant
Restrictor
valve
Restrictor valve
Indoor unitOutdoor unit
Indoor
heat
exchanger
4•way
valve
Accumulator
Compressor
Outdoor
heat
exchanger
Capillary tubes
for cooling
Capillary
tubes for
heating
Liquid section
of piping
Low-pressure
two-phase
refrigerant
Restrictor
valve
Restrictor valve
COOLING
HEATING
FEATURES
1. REDI-CHARGED REFRIGERANT SYSTEM
The industry’s first redi-charged refrigerant system.
There is no need to adjust the amount of refrigerant to match the piping length
on- site unless lines exceed 100ft.
You will see a major reduction in installation time and labor costs.
The unique refrigerant circuit and a large accumulator always control the refrigerant to its optimum condition unless the
pipe length exceeds 100ft. The additional refrigerant charging work in the field which often caused
uncertain problems heretofore is completely eliminated. This unique system serves to improve the quality of work and
reliability, and also helps to speed up the installation work.
Figure 1. Normal Refrigerant Circulation SystemFigure 2. New Refrigerant Circulation System
With normal circulation systems, a high-pressure refrigerant, condensed for cooling by the outdoor heat exchanger, is
reduced in pressure by capillary tubes in the indoor unit after passing through the restrictor valve in the outdoor unit (see
Figure 1). With the new circulation system, the direction of the restrictor valve is reversed as shown in Figure 2, and the
condensed high pressure refrigerant is reduced in pressure by the capillary tubes in the outdoor unit. This results in a “twophase refrigerant” of reduced pressure in the liquid section of the piping, The density of this two-phase refrigerant is 1/3~
1/2 of that of the high pressure liquid refrigerant, and thus is required in smaller amounts (see Figures 1 and 2). As a result,
the length of the piping can be extended further, and the effects of height differences are reduced. These new circulation
system are also equipped with a large accumulator which allows the refrigerant required for the 100ft piping length to be
enclosed in the outdoor unit. The result is an air conditioner that requires no charging unless piping is extended beyond
100ft.
2. HIGH RELIABILITY AND EASY SERVICING
In addition to the self-diagnostic function, units are also equipped with a 3-minute time delay mechanism (cooling), an auto
restart function, an emergency operation function, a test run switch, etc., to assure high reliability and easy servicing.
3. FOUR-WAY PIPING ACCESS MAKES
INSTALLATION LAYOUT EASY
Piping on the outdoor unit may be connected from either of
four directions: front, rear, side or beneath the base.
This easy-access design makes it possible to install a
number of units in a compact arrangement at a single site.
The outdoor unit allows for unheard-of flexibility in
determining a piping layout, thus greatly simplifying
installation.
4. FRONT-ACCESS FACILITATES
MAINTENANCE
The outdoor unit has been designed with a front-access
service panel that allows easy access to all maintenance
point, regardless of the installation layout. What’s more, this
front panel may be removed by loosening only two screws.
It all adds up to greatly simplified maintenance work.
2
TECHNICAL CHANGE2
(OC245 REVISED EDITION-A)
Change of the service parts.
Refer to 13.PARTS LIST for the details.
[Change points]
BYPASS VALVE and BYPASS VALVE SOLENOID COIL has been changed to externals.
It has not been functionally changed.
Therefore, the piping connected with the BYPASS VALVE has been changed.
Since the indoor and outdoor connecting wires has polarity,make sure to connect the same terminal numbers(1,2,3)for indoor and outdoor units.
CAUTION FOR INDOOR AND OUTDOOR CONNECTING WIRES
wiring connection in the following Procedure.
Since the indoor transformer(T) is connected with 230V power,if 208V power is used,change the
2. Symbols used in wiring diagram above are. :Terminal block :Connector :PC board insertion tab.
Bypass valve ON
4-Way valve ON
63H1 ON
Heating indoor command
ORANGE
230V
WHITE
RED
208V
When Power Supply is 208Vw
White connector
S
to output display(light).
in flushing mode. Pressing the switch again returns
SW2
but pressing displays the past check contents
The output display (light) remains during operation
loaded on the microcomputer.
SW1
Pressing erases the past check contents
SW3
(when both No.1 and 2 of are"OFF")
How to use SW1 and 2
Since LD8 lights when normal power is turned"ON",check the power supply with the"ON"or"OFF"LD8.
CAUTIONS FOR POWER SUPPLY WIRING
The compressor stops by disconnecting the white connector as shown at the right.
The connector marked is to turn the compressor ON-OFF during servicing.
CAUTION FOR SERVICING
1. If the operation stops to function of the protection device,the check display flushes.
NOTES:
Defective input
RT overheat protection
63H2 functions
Pipe temp.sensor short/open
Check display(flush)
Crankcase heater ON
Outdoor fan ON
Compressor ON
Compressor indoor command
Output display(light)
LD8
LD7
LD6
LD5
LD4
LD3
LD2
LD1
LED NO.
ÆÆ
Main functions of LED
w
PUH30EK PUH30EK1 PUH30EK2
12
MODELS : PUH36EK PUH36EK1 PUH36EK2
PUH42EK PUH42EK1
PUH42EK7
CRANKCASE HEATERHC
C1,2
FAN MOTOR CAPACITOR
CCOMPRESSOR CAPACITOR
COMPRESSOR START CAPACITORC5
FC(O.B)
F(O.B)
21S4
FAN CONTROLLER
FUSE(6A)
4-WAY VALVE SOLENOID COIL
MC
O.B
SW1•2•3(O.B)
T
TB1,3
RT
BYPASS VALVE SOLENOID COIL21R
LD2
1234
LD3
4
RED
BLK
SW3
LED
LD4
LD5
RED
RED
LD6
RED
21R
X12(O.B)
LD7
LD8
SV
WHT
WHT
LED(CHECK,SERVICE)LD1~LD8
1
TO INDOOR UNIT
CONNECTING WIRES
DC 12V (polar)
RED AC12.3V
POWER SUPPLY
1[ 208/230V
60Hz
Main functions of LED
LED NO.
LD1
LD2
LD3
LD4
LD5
LD6
LD7
LD8
1. If the operation stops to function of the protection device,the check display flushes.NOTES :
2. Symbols used in wiring diagram above are. :Terminal block :Connector :PC board insertion tab.
CAUTION FOR SERVICING
The connector marked is to turn the compressor ON-OFF during servicing.
The compressor stops by disconnecting the white connector as shown at the right.
CAUTIONS FOR POWER SUPPLY WIRING
Since LD8 lights when normal power is turned"ON",check the power supply with the"ON"or"OFF"LD8.
W
Since the indoor transformer(T) is connected with 230V power,if 208V power is used,change the
wiring connection in the following Procedure.
CAUTION FOR INDOOR AND OUTDOOR CONNECTING WIRES
Since the indoor and outdoor connecting wires has polarity,make sure to connect the same terminal numbers(1,2,3)for indoor and outdoor units.
Compressor indoor command
Heating indoor command
63H1 ON
Compressor ON
Outdoor fan ON
4-Way valve ON
Bypass valve ON
Crankcase heater ON
YLW
2
ORN
3
BRN
TB3
AC12.3V
BRN
L1
L2
GR
(when both No.1 and 2 of are "OFF")How to use SW1 and 2
Pressing erases the past check contents
loaded on the microcomputer.
The output display (light) remains during operation
but pressing displays the past check contents
in flushing mode. Pressing the switch again returns
to output display(light).
21S4 RELAY
21R RELAY
VARISTOR
COMPRESSOR CONTACTOR
CONTROL HIGH PRESSURE SWITCH
PROTECT HIGH PRESSURE SWITCH
COMPRESSOR START RELAY
RESISTOR
DISCHARGE THERMAL SWITCH
5
BRN
BRN
PUH42EK7
Only
52C
1/L1
2/T1
6/T3
5/L3
SW1
SW2
FC
26C
63H2
51CM
RED
RED
BLU
BLU
63H263H1
3
208V
230V
BLU
19
19
YLW
YLW
YLW
YLW
26C
PUH42EK , PUH42EK1 Only
BLU
WHT
WHT
R
BLU
C5
When Power Supply is 208V
W
ORANGE
WHT
1
2
MF1
MF2
RED
WHITERED
MF2
MF1
BLU
WHT
RED
ORN
YLW
BRN
WHT
BLU
BLU
C
RED
4
3
2
1
1
2
3
4
WHT
BLU
BLU
WHT
RED
ORN
YLW
BRN
WHT
BLU
R
C
S
C1
C2
MC
13