Caution
● Only the Power display lights when the unit is stopped and power supplied to the unit.
● When power is turned ON for the first time the (CENTRAL CTRL) display appears to go off momentarily but this is not a
malfunction.
● When the central control remote control unit, which is sold separately, is used the ON-OFF button, Operation switch button
and i TEMP button do not operate.
● “NOT AVAILABLE” is displayed when the Air speed button and the Louver button are pressed.This indicates that this room unit
is not equipped with the fan direction adjustment function and the louver function.
● When power is turned ON for the first time, it is normal that “ HO ” is displayed on the room temperature indication (For max.
2 minutes).Please wait until this “ HO ” indication disapear then start the operation.
CENTRALLY
CONTROLLED display
This indicates when the unit is
controlled by optional features such
as central control type remote
controller.
TIMER display
This indicates when the continuous
operation and time operation modes
are set.
It also display the time for the timer
operation at the same time as when
it is set.
OPERATION MODE display
This indicates the operation mode.
STANDBY display
This indicates when the standby
mode is set from the time the sleep
operation starts until the heating air
is discharged.
DEFROST display
This indicates when the defrost
operation is performed.
CHECK display
This indicates when a malfunction
has occurred in the unit which should
be checked.
POWER display
This display lights when the filter
need to be cleaned.
SET TEMPERATURE display
This displays the selected setting
temperature.
CLOCK display
The current time , start time and stop
time can be displayed in tensecond
intervals by pressing the time switch
button. The start time or stop time is
always displayed during the timer
operation.
FAN SPEED display
The selected fan speed is displayed.
● Display
In this display example on the
bottom left, a condition where
all display lamps light is
shown for explanation
purposes although this differs
from actual operation.
display
This display lights in the check mode
or when a test operation is
performed.
CHECK MODE
TEST RUN
ROOM TEMPERATURE display
The temperature of the suction air is
displayed during operation. The
display range is 8° to 39°C. The
display flashes 8°C when the actual
temperature is less than 8° and
flashes 39°C when the actual
temperature is greater than 39°C.
Operation lamp
This lamp lights during operation,
goes off when the unit stops and
flashes when amalfunction occurs.