s Before operating the unit, make sure you read all the “Safety
precautions”.
s “Safety precautions” lists important points about safety.
Please be sure to follow them.
Symbols used in the text
Warning:
Describes precautions that should be observed to avoid the risk of injury or
death to the user.
Caution:
Describes precautions that should be observed to prevent damage to the
unit.
Symbols put on the unit
: Indicates an action that must be avoided.
: Indicates that important instructions must be followed.
: Indicates a part which must be grounded.
: Beware of electric shock. (This symbol is displayed on the main unit label.)
<Color: yellow>
Warning:
Carefully read the labels affixed to the main unit.
1.1. Installation
s After you have read this manual, keep it and the Installation Manual in a
safe place for easy reference whenever a question arises. If the unit is
going to be operated by another person, make sure that this manual is
given to him or her.
Warning:
• The unit should not be installed by the user. Ask the dealer or an authorized company to install the unit. If the unit is installed improperly, water
leakage, electric shock or fire may result.
• Use only accessories authorized by Mitsubishi Electric and ask your
dealer or an authorized company to install them. If accessories are installed improperly, water leakage, electric shock or fire may result.
• The Installation Manual details the suggested installation method. Any
structural alteration necessary for installation must comply with local
building code requirements.
• Never repair the unit or transfer it to another site by yourself. If repair is
performed improperly, water leakage, electric shock or fire may result. If
you need to have the unit repaired or moved, consult your dealer.
• The appliance is not intended for use by young children or infirm persons without supervision.
• Young children should be supervised to ensure that they do not play
with the appliance.
3.5. Setting the day of the week and time ........................................ 6
3.6. Using the timer .......................................................................... 7
3.7. Locking the remote controller buttons (Operation function limit
• The outdoor unit must be installed on a stable, level surface, in a place
where there is no accumulation of snow, leaves or rubbish.
• Do not stand on, or place any items on the unit. You may fall down or the
item may fall, causing injury.
Caution:
The outdoor unit should be installed in a location where air and noise emitted by the unit will not disturb the neighbours.
2) Indoor unit
Warning:
The indoor unit should be securely installed. If the unit is loosely mounted, it
may fall, causing injury.
3) Remote controller
Warning:
The remote controller should be installed in such a way that children cannot
play with it.
4) Drain hose
Caution:
Make sure that the drain hose is installed so that drainage can go ahead
smoothly. Incorrect installation may result in water leakage, causing damage to furniture.
5) Power line, fuse or circuit breaker
Warning:
• Make sure that the unit is powered by a dedicated line. Other appliances
connected to the same line could cause an overload.
• Make sure that there is a main power switch.
• Be sure to adhere to the unit’s voltage and fuse or circuit breaker ratings.
Never use a piece of wire or a fuse with a higher rating than the one
specified.
6) Grounding
Caution:
• The unit must be properly grounded. Never connect the grounding wire
to a gas pipe, water pipe, lightning conductor or telephone grounding
wire. If the unit is not grounded properly, electric shock may result.
• Check frequently that the ground wire from the outdoor unit is properly
connected to both the unit’s ground terminal and the grounding electrode.
GBDF
E
INL
SWP
3
1.2. During operation
Caution:
• Do not use any sharp object to push the buttons, as this may damage the
remote controller.
• Do not twist or tug on the remote controller cord as this may damage the
remote controller and cause malfunction.
• Never remove the upper case of the remote controller. It is dangerous to
remove the upper case of the remote controller and touch the printed
circuit boards inside. Doing so can result in fire and failure.
• Never wipe the remote controller with benzene, thinner, chemical rags,
etc. Doing so can result in discoloration and failure. To remove heavy
stains, soak a cloth in neutral detergent mixed with water, wring it out
thoroughly, wipe the stains off, and wipe again with a dry cloth.
• Never block or cover the indoor or outdoor unit’s intakes or outlets. Tall
items of furniture underneath the indoor unit, or bulky items such as
large boxes placed close to the outdoor unit will reduce the unit’s efficiency.
Warning:
• Do not splash water over the unit and do not touch the unit with wet
hands. An electric shock may result.
• Do not spray combustible gas close to the unit. Fire may result.
• Do not place a gas heater or any other open-flame appliance where it will
be exposed to the air discharged from the unit. Incomplete combustion
may result.
GB
Warning:
• Do not remove the front panel or the fan guard from the outdoor unit
when it is running. You could be injured if you touch rotating, hot or highvoltage parts.
• Never insert fingers, sticks etc. into the intakes or outlets, otherwise injury may result, since the fan inside the unit rotates at high speed. Exer-
D
cise particular care when children are present.
• If you detect odd smells, stop using the unit, turn off the power switch
and consult your dealer. Otherwise, a breakdown, electric shock or fire
may result.
• When you notice exceptionally abnormal noise or vibration, stop operation, turn off the power switch, and contact your dealer.
• Do not over-cool. The most suitable inside temperature is one that is
F
within 5
• Do not leave handicapped people or infants sitting or standing in the
• Do not direct the airflow at plants or caged pets.
E
• Ventilate the room frequently. If the unit is operated continuously in a
°C of the outside temperature.
path of the airflow from the air-conditioner. This could cause health problems.
Caution:
closed room for a long period of time, the air will become stale.
In case of failure
Warning:
• Never remodel the air conditioner. Consult your dealer for any repair service. Improper repair work can result in water leakage, electric shock, fire,
etc.
• If the remote controller displays an error indication, the air conditioner
does not run, or there is any abnormality, stop operation and contact
your dealer. Leaving the unit as it is under such conditions can result in
fire or failure.
• If the power breaker is frequently activated, get in touch with your dealer.
Leaving it as it is can result in fire or failure.
• If the refrigeration gas blows out or leaks, stop the operation of the air
conditioner, thoroughly ventilate the room, and contact your dealer. Leaving the unit as it is can result in accidents due to oxygen deficiency.
When the air conditioner is not to be used for a long
time
• If the air conditioner is not to be used for a long time due to a seasonal
change, etc., run it for 4 - 5 hours with the air blowing until the inside is
completely dry. Failing to do so can result in the growth of unhygienic,
unhealthy mold in scattered areas throughout the room.
• When it is not to be used for an extended time, keep the [power supply]
turned OFF.
If the power supply is kept on, several watts or several tens of watts will
be wasted. Also, the accumulation of dust, etc., can result in fire.
• Keep the power switched ON for more than 12 hours before starting operation. Do not turn the power supply OFF during seasons of heavy use.
Doing so can result in failure.
1.3. Disposing of the unit
Warning:
When you need to dispose of the unit, consult your dealer. If pipes are removed incorrectly, refrigerant (fluorocarbon gas) may blow out and come
into contact with your skin, causing injury. Releasing refrigerant into the
atmosphere also damages the environment.
2. Names and functions of various parts
INL
Indoor unit
• Air inlet: Return the indoor air.
• Filter: Part to remove visible dust and dirt.
• Air outlet: Blow the cooled/warmed air into the room.
Model PEA-170, 200, 250
[Ceiling concealed type]
SW
P
(For details on how to clean, refer to page 11.)
[Fig. 2.0.1](P.2)
A Air outletB Air inletC Air filter
LCD remote Controller
• Check out your remote controller.
Different controllers are used for different systems.
[Fig. 2.0.2](P.2)
A LCD remote controller
4
3. Operation
Remote controller-Button
Opening the door.
1 Set Temperature buttons
Down
Up
2 Timer Menu button (Monitor/Set button)
3 Mode button (Return button)
4 Set Time buttons
Back
Ahead
5 Timer On/Off button (Set Day button)
6 Louver button ( Operation button)
To preceding operation number.
7 Ventilation button ( Operation button)
To next operation number.
8 ON/OFF button
9 Fan Speed button
1
2
3
PAR-21MAA
TEMP.
MENU
ON/OFF
BACKDAY
MONITOR/SET
CLOCK
OPERATION
ON/OFF
FILTER
CHECK
CLEAR
TEST
8
9
0
A
B
C
45 67
0 Filter button (<Enter> button)
A Test Run button
B Check button (Clear button)
C Airflow Up/Down button
GBDF
Notes:
• If you press a button for a feature that is not installed at the indoor unit,
the remote controller will display the “Not Available” message.
• If you are using the remote controller to drive multiple indoor units, this
message will appear only if the feature is not present at the parent unit.
• Never expose the remote controller to direct sunlight. Doing so can result in the erroneous measurement of room temperature.
• Never place any obstacle around the lower right-hand section of the remote controller. Doing so can result in the erroneous measurement of
room temperature.
Remote controller-Display
C
D
E
FGHJKMIL
A Day-of-Week
Shows the current day of the week.
Time/Timer Display
Shows the current time, unless the simple or Auto Off timer is set.
If the simple or Auto Off timer is set, shows the time remaining.
B “Sensor” indication
Displayed when the remote controller sensor is used.
C Identifies the current operation
Shows the operating mode, etc.
* Multilanguage display is supported.
D “Centrally Controlled” indicator
Indicates that operation of the remote controller has been prohibited by a main controller.
E “Timer Is Off” indicator
Indicates that the timer is off.
F Temperature Setting
Shows the target temperature.
G Up/Down Air Direction indicator
The indicator shows the direction of the outcoming airflow.
H “One Hour Only” indicator
Displayed if the airflow is set to weak and downward during COOL or DRY mode. (Operation varies according to model.)
The indicator goes off after one hour, at which time the airflow direction also changes.
A
TIME SUN MON TUE WED THU FRI SAT
TIMER
AFTER
ERROR CODE
˚F˚C
ONLY1Hr.
B
ON
OFFHrAFTER
˚F˚C
I Louver display
J Room Temperature display
K (Power On indicator)
L Ventilation indicator
M Fan Speed indicator
N “Locked” indicator
O “Clean The Filter” indicator
P Timer indicators
FUNCTION
FILTER
WEEKLY
SIMPLE
AUTO OFF
Indicates the action of the swing louver. Does not appear if the louver is stationary.
Shows the room temperature.
Indicates that the power is on.
Appears when the unit is running in Ventilation mode.
Shows the selected fan speed.
Indicates that remote controller buttons have been locked.
Comes on when it is time to clean the filter.
The indicator comes on if the corresponding timer is set.
N
O
P
Note:
• For purposes of this explanation, all parts of the display are shown as lit.
During actual operation, only the relevant items will be lit.
E
INL
SWP
5
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.