Mitsubishi MXZ-A14WV-E1, MXZ-A18WV-E1, MXZ-A26WV-E1, MXZ-A32WV-E1 Service Manual

SERVICE MANUAL
HFC
utilized
R410A
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
Inverter-controlled multi system type Models
Revision C:
“Check of HPS” has been corrected.
Please void OB319 REVISED EDITION-B.
No. OB319
REVISED EDITION-C
MXZ-A14WV ­MXZ-A14WV ­MXZ-A18WV ­MXZ-A18WV ­MXZ-A26WV ­MXZ-A32WV -
MXZ-A14WV ­MXZ-A14WV ­MXZ-A18WV ­MXZ-A18WV -
E1
E2
E1
E2
E1
E2
E1
E2
E1
E1
CONTENTS
1. TECHNICAL CHANGES ····································2
2. PART NAMES AND FUNCTIONS······················6
3. INDOOR/OUTDOOR CORRESPONDENCE TABLE ···························6
4. INDOOR UNITS COMBINATION ·······················9
5. SPECIFICATION···············································21
6. NOISE CRITERIA CURVES·····························23
7. OUTLINES AND DIMENSIONS·······················24
9. REFRIGERANT SYSTEM DIAGRAM··············30
10. PERFORMANCE CURVES······························33
11. ACTUAT OR CONTROL····································47
12. TROUBLESHOOTING ······································48
13. DISASSEMBLY INSTRUCTIONS·····················67
14. PARTS LIST······················································74
15. OPTIONAL PARTS ···········································79
NOTE:
•This service manual describes technical data of outdoor units. As for indoor units, refer to the service manual OB307, OB321, OB327, OB329, OB336, OB345, OC302 or OC303.
Revision A:
• MXZ-A14WV - has been added.
E1
Revision B:
• MXZ-A14WV - and MXZ-A18WV - have been added.
E2E2
Revision C:
• “Check of HPS” has been corrected.
1
MXZ-14WV -
New model
MXZ-18TV - MXZ-A18WV -
1. Outdoor model has been changed.
2. Refrigerant has been changed. (R22R410A)
TECHNICAL CHANGES
E1
E1E2
MXZ-24UV - MXZ-A26WV -
1. Cooling capacity has been made larger. (7.1kW7.2kW)
2. Combinations of connectable indoor units have been increased.
3. Capacity class of connectable indoor units have been made larger.
4. Compressor has been changed. (THV247FBATNB220FMCH)
5. Outdoor fan motor has been changed. (RA6V60-BAPM8H60-UA)
6. Refrigerant has been changed. (R22R410A)
7. Refrigerant system diagram has been changed.
• 1 of 2 high pressure switch has been removed.
• Accumulator has been removed.
• Receiver has been added.
MXZ-32SV - MXZ-A32WV -
1. Combinations of connectable indoor units have been increased.
2. Capacity class of connectable indoor units have been made larger.
3. Compressor has been changed. (THV247FBATNB220FMCH)
4. Outdoor fan motor has been changed. (RA6V60-BAPM8H60-UA)
5. Refrigerant has been changed. (R22R410A)
6. Refrigerant system diagram has been changed.
• 1 of 2 high pressure switch has been removed.
• Accumulator has been removed.
• Receiver has been added.
MXZ-14WV - MXZ-A14WV -
1. Reversing valve has been changed.
2. Reversing valve coil has been changed.
3. Outdoor noise filter P.C.board has been changed.
E1E2
E1E2
E2E1
MXZ-18WV - MXZ-A18WV -
1. Reversing valve has been changed.
2. Reversing valve coil has been changed.
3. Outdoor noise filter P.C.board has been changed.
E2E1
2
Refrigeration
oil
Refrigerant
New refrigerant
R410A
HFC-32: HFC-125 (50%:50%)
Pseudo-azeotropic refrigerant
Not included
A1/A1
72.6
-51.4
1.557 64
Non combustible
0
1730
From liquid phase in cylinder
Possible
Incompatible oil
Non Non
Previous refrigerant
R22
R22 (100%)
Single refrigerant
Included
A1
86.5
-40.8
0.94
44.4
Non combustible
0.055 1700
Gas phase
Possible
Compatible oil
Light yellow
Non
Refrigerant Composition (Ratio) Refrigerant handling Chlorine Safety group (ASHRAE) Molecular weight Boiling point (:) Steam pressure [25:](Mpa) Saturated steam density [25:](Kg/K) Combustibility ODP w1 GWP w2 Refrigerant charge method Additional charge on leakage Kind Color Smell
w1:Ozone Destruction Parameter : based on CFC-11 w2 :Global Warmth Parameter : based on CO
2
INFORMATION FOR THE AIR CONDITIONER WITH R410A REFRIGERANT
New Specification Current Specification
The incompatible refrigeration oil easily separates from refrigerant and is in the upper layer inside the suction muffler. Raising position of the oil back hole enables to back the refrigeration oil of the upper layer to flow back to the compressor.
Since refrigerant and refrigeration oil are compatible each, refrigeration oil goes back to the compressor through the lower position oil back hole.
Compressor
Suction muffler
Oil back hole
Refrigeration oil
Refrigerant
Compressor
Suction muffler
Oil back hole
Refrigerating oil /Refrigerant
Compressor
• This room air conditioner adopts HFC refrigerant (R410A) which never destroys the ozone layer.
• Pay particular attention to the following points, though the basic installation procedure is same as that for R22 conditioners. 1 As R410A has working pressure approximate 1.6 times as high as that of R22, some special tools and piping parts/
materials are required. Refer to the table below.
2 Take sufficient care not to allow water and other contaminations to enter the R410A refrigerant during storage and
installation, since it is more susceptible to contaminations than R22.
3 For refrigerant piping, use clean, pressure-proof parts/materials specifically designed for R410A. (Refer to 2. Refrigerant
piping.)
4 Composition change may occur in R410A since it is a mixed refrigerant. When charging, charge liquid refrigerant to prevent
composition change.
NOTE : The unit of pressure has been changed to MPa on the international system of units(SI unit system).
The conversion factor is: 1(MPa [Gauge]) =10.2(kgf/
ff
[Gauge])
3
-30 -20 -10 0 10 20
30
40 50 60
-0.5
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
(MPa [Gauge])
R410A R22
Conversion chart of refrigerant temperature and pressure
Saturated liquid pressure
(:)
NOTE : The unit of pressure has been changed to MPa on the
R410A tools Can R22 tools be used?
Gas leak detector
R410A has high pressures beyond the measurement range of existing gauges. Port diameters have been changed to prevent any other refrigerant from being charged into the unit.
Hose material and cap size have been changed to improve the pressure resistance.
Dedicated for HFC refrigerant.
6.35 mm and 9.52 mm
Description
Clamp bar hole has been enlarged to reinforce the spring strength in the tool. Provided for flaring work (to be used with R22 flare tool).
Provided to prevent the back flow of oil. This adapter enables you to use vacuum pumps.
It is difficult to measure R410A with a charging cylinder because the refrigerant bubbles due to high pressure and high-speed vaporization
No
No
No
Yes
Yes
New
New
New
Gauge manifold
Charge hose
Torque wrench
Flare tool Flare gauge
Vacuum pump adapter
Electronic scale for refrigerant charging
No : Not Substitutable for R410A Yes : Substitutable for R410A
No 12.7 mm and 15.88 mm
Wall thickness
Outside diameter
Pipe
mm
For liquid
For gas
6.35/9.52
9.52
12.7
15.88
0.8 mm/0.8 mm
0.8 mm
0.8 mm
1.0 mm
Heat resisting foam plastic Specific gravity 0.045 Thickness 8 mm
Insulation material
international system of units(SI unit system).
The conversion factor is: 1(MPa [Gauge]) =10.2(kgf/ff[Gauge])
1.Tools dedicated for the air conditioner with R410A refrigerant
The following tools are required for R410A refrigerant. Some R22 tools can be substituted for R410A tools. The diameter of the service port on the stop valve in outdoor unit has been changed to prevent any other refrigerant being charged into the unit. Cap size has been changed from 7/16 UNF with 20 threads to 1/2 UNF with 20 threads.
2.Refrigerant piping
1 Specifications
Use the refrigerant pipes that meet the following specifications.
• Use a copper pipe or a copper-alloy seamless pipe with a thickness of 0.8 mm. Never use any pipe with a thickness less than 0.8mm, as the pressure resistance is insufficient.
4
2 Flaring work and flare nut
Flaring work for R410A pipe differs from that for R22 pipe. For details of flaring work, refer to Installation manual “FLARING WORK”.
Pipe diameter
mm
6.35
9.52
12.7
15.88
Dimension of flare nut
R410A
17 22 26 29
R22
17 22 24 27
3.Refrigerant oil
Apply the special refrigeration oil (accessories: packed with indoor unit) to the flare and the union seat surfaces.
4.Air purge
• Do not discharge the refrigerant into the atmosphere. Take care not to discharge refrigerant into the atmosphere during installation, reinstallation, or repairs to the refrigerant
circuit.
• Use the vacuum pump for air purging for the purpose of environmental protection.
5.Additional charge
For additional charging, charge the refrigerant from liquid phase of the gas cylinder. If the refrigerant is charged from the gas phase, composition change may occur in the refrigerant inside the cylinder and the outdoor unit. In this case, ability of the refrigeration cycle decreases or normal operation can be impossible. However, charging the liquid refrigerant all at once may cause the compressor to be locked. Thus, charge the refrigerant slowly.
Union
Stop valve
Indoor unit
Refrigerant gas cylinder operating valve
Liquid pipe Gas pipe
Service port
Gauge manifold valve (for R410A)
Charge hose (for R410A)
Refrigerant gas cylinder for R410A with siphon
Refrigerant (liquid)
Electronic scale for refrigerant charging
Outdoor unit
5
2
MXZ-A14WV-
E1
MXZ-A14WV-
E2
OUTDOOR UNIT
There is no combination other than this table.
Combination of the
connectable indoor units
07+07 07+09 07+12 09+09 09+12
PART NAMES AND FUNCTIONS
OUTDOOR UNIT
MXZ-A14WV­MXZ-A14WV­MXZ-A18WV­MXZ-A18WV-
ACCESSORIES
MXZ-A14WV­MXZ-A14WV­MXZ-A18WV­MXZ-A18WV­MXZ-A26WV­MXZ-A32WV-
E1
E2
E1
E2
Air inlet
(Back and side)
Air outlet
Drain outlet
E1
E2
E1
E2
E1
E1
MXZ-A26WV­MXZ-A32WV-
E1
E1
Air inlet
(Back and side)
Air outlet
Drain outlet
1
Drain socket
2
Drain cap
3
MXZ-A14WV ­MXZ-A14WV -
INDOOR/ OUTDOOR CORRESPONDENCE TABLE
E1
E2
1 2
MXZ-A18WV ­MXZ-A18WV -
Combination of the
connectable indoor units
E1
E2
OUTDOOR UNIT
MXZ-A18WV­MXZ-A18WV-
07+07 07+09 07+12 09+09 09+12 12+12
E1 E2
There is no combination other than this table.
6
MXZ-A26WV -
E1
OUTDOOR UNIT
Combination of the connectable indoor units
There is no combination other than this table.
MXZ-A26WV-
07+07 07+09 07+12 07+18 07+24 07+26 09+09 09+12 09+18 09+24 09+26 12+12 12+18 12+24 12+26 18+18 18+24
18+26 07+07+07 07+07+09 07+07+12 07+07+18 07+07+24 07+07+26 07+09+09 07+09+12 07+09+18 07+09+24 07+09+26 07+12+12 07+12+18 07+12+24 07+12+26 07+18+18 07+18+24 07+18+26 09+09+09 09+09+12 09+09+18 09+09+24 09+09+26 09+12+12 09+12+18 09+12+24 09+12+26 09+18+18 09+18+24 12+12+12 12+12+18 12+12+24 12+12+26 12+18+18 12+18+24
7
E1
There is no combination other than this table.
MXZ-A32WV-
E1
OUTDOOR UNIT
MXZ-A32WV-
E1
OUTDOOR UNIT
Combination of the connectable indoor units
07+07 07+09 07+12 07+18 07+24 07+26 09+09 09+12 09+18 09+24 09+26 12+12 12+18 12+24 12+26 18+18 18+24 18+26 24+24
24+26 07+07+07 07+07+09 07+07+12 07+07+18 07+07+24 07+07+26 07+09+09 07+09+12 07+09+18 07+09+24 07+09+26 07+12+12 07+12+18 07+12+24 07+12+26 07+18+18 07+18+24 07+18+26 09+09+09 09+09+12 09+09+18 09+09+24 09+09+26 09+12+12 09+12+18 09+12+24 09+12+26 09+18+18
Combination of the connectable indoor units
09+18+24 12+12+12 12+12+18 12+12+24 12+12+26 12+18+18
12+18+24 07+07+07+07 07+07+07+09 07+07+07+12 07+07+07+18 07+07+07+24 07+07+07+26 07+07+09+09 07+07+09+12 07+07+09+18 07+07+09+24 07+07+09+26 07+07+12+12 07+07+12+18 07+07+12+24 07+07+18+18 07+09+09+09 07+09+09+12 07+09+09+18 07+09+09+24 07+09+12+12 07+09+12+18 07+09+12+24 07+12+12+12 07+12+12+18 09+09+09+09 09+09+09+12 09+09+09+18 09+09+09+24 09+09+12+12 09+09+12+18 09+12+12+12 12+12+12+12
MXZ-A32WV -
E1
8
INDOOR UNITS COMBINATION4
NOTE: Electrical data is for outdoor unit only.
07 09
12 07+07 07+09 07+12 09+09 09+12
90 90 90 90 90 90 90 90
4.73
5.17
6.76
5.22
5.17
5.17
5.12
5.12
3.3
(0.9-4.0)
3.6
(0.9-4.5)
4.0
(0.9-4.8)
4.4
(1.53-4.8)
4.4
(1.53-4.8)
4.4
(1.55-4.9)
4.4
(1.55-4.9)
4.5
(1.56-5.0)
0.980
(0.230-1.120)
1.070
(0.230-1.200)
1.400
(0.220-1.680)
1.080
(0.300-1.180)
1.070
(0.300-1.180)
1.070
(0.300-1.180)
1.060
(0.300-1.180)
1.060
(0.300-1.190)
– – –
2.20
2.29
2.62
2.20
2.59
3.3
3.6
4.0
2.20
2.11
1.78
2.20
1.91
Indoor units
combination
Unit A Unit B
Heating capacity (kW)
Total
Outdoor unit
power consumption
(kW)
Current
(A)
Power
factor
(%)
230V
07
09
12
07+07 07+09 07+12 09+09 09+12
90 90 90 90 90 90 90 90
3.62
3.91
5.70
5.31
5.41
5.46
5.46
5.55
2.3
(0.9-2.95)
2.5
(0.9-3.30)
3.4
(0.9-4.00)
3.8
(1.49-4.30)
3.9
(1.49-4.30)
3.9
(1.51-4.40)
3.9
(1.51-4.40)
4.0
(1.53-4.50)
0.750
(0.230-1.000)
0.810
(0.230-1.070)
1.180
(0.220-1.450)
1.100
(0.370-1.280)
1.120
(0.370-1.280)
1.130
(0.370-1.330)
1.130
(0.370-1.330)
1.150
(0.370-1.330)
– – –
1.90
2.03
2.33
1.95
2.31
2.3
2.5
3.4
1.90
1.87
1.57
1.95
1.69
Indoor units
combination
Unit A Unit B
Cooling capacity (kW)
Total
Outdoor unit
power consumption
(kW)
Current
(A)
Power
factor
(%)
230V
NOTE: Electrical data is for outdoor unit only.
MXZ-A14WV -
E1
MXZ-A14WV -
E2
9
NOTE: Electrical data is for outdoor unit only.
07 09
12 07+07 07+09 07+12 09+09 09+12 12+12
90 90 90 90 90 90 90 90 90
4.73
5.14
6.76
9.32
9.37
9.03
9.28
8.91
8.55
3.3
(0.9-4.0)
3.6
(0.9-4.5)
4.0
(0.9-4.8)
6.1
(1.53-6.70)
6.2
(1.53-6.80)
6.5
(1.55-7.00)
6.5
(1.55-7.0)
6.55
(1.56-7.1)
6.6
(1.58-7.2)
0.980
(0.225-1.115)
1.065
(0.225-1.195)
1.400
(0.220-1.680)
1.930
(0.300-2.070)
1.940
(0.300-2.040)
1.870
(0.295-1.980)
1.920
(0.295-2.010)
1.845
(0.295-1.950)
1.770
(0.290-1.850)
– – –
3.05
3.23
3.88
3.25
3.77
3.30
3.3
3.6
4.0
3.05
2.97
2.62
3.25
2.78
3.30
Indoor units
combination
Unit A Unit B
Heating capacity (kW)
Total
Outdoor unit
power consumption
(kW)
Current
(A)
Power
factor
(%)
230V
07 09
12 07+07 07+09 07+12 09+09 09+12 12+12
90 90 90 90 90 90 90 90 90
3.62
3.91
5.70
7.15
7.73
7.78
8.60
8.84
8.99
2.3
(0.9-2.95)
2.5
(0.9-3.30)
3.4
(0.9-4.00)
4.6
(1.49-5.30)
4.8
(1.49-5.40)
5.0
(1.51-5.60)
5.0
(1.51-5.55)
5.3
(1.53-5.80)
5.4
(1.55-6.00)
0.750
(0.225-1.000)
0.810
(0.225-1.070)
1.180
(0.220-1.450)
1.480
(0.370-2.060)
1.600
(0.370-2.070)
1.610
(0.365-2.100)
1.780
(0.370-2.105)
1.830
(0.365-2.110)
1.860
(0.370-2.130)
– – –
2.3
2.5
2.98
2.5
3.1
2.65
2.3
2.5
3.4
2.3
2.3
2.02
2.5
2.2
2.65
Indoor units
combination
Unit A Unit B
Cooling capacity (kW)
Total
Outdoor unit
power consumption
(kW)
Current
(A)
Power
factor
(%)
230V
NOTE: Electrical data is for outdoor unit only.
MXZ-A18WV -
E1
MXZ-A18WV -
E2
10
MXZ-A26WV -
Indoor units
combination
07 09 12 18 24
26 07+07 07+09 07+12 07+18 07+24 07+26 09+09 09+12 09+18 09+24 09+26 12+12 12+18 12+24 12+26 18+18 18+24 18+26
07+07+07 07+07+09 07+07+12 07+07+18 07+07+24 07+07+26 07+09+09 07+09+12 07+09+18 07+09+24
E1
Cooling capacity (kW)
Unit A Unit B Unit C
2.3
2.5
3.4
5.0
6.0
7.1
2.3
2.1
2.1
2.01
1.62
1.52
2.5
2.52
2.4
1.96
1.85
3.4
2.88
2.4
2.27
3.6
3.08
2.94
2.3
2.16
1.93
1.58
1.32
1.26
2.01
1.8
1.48
1.26
– – – – – –
2.3
2.7
3.6
5.18
5.57
5.67
2.5
3.37
4.8
5.23
5.34
3.4
4.32
4.8
4.92
3.6
4.11
4.25
2.3
2.16
1.93
1.58
1.32
1.26
2.59
2.31
1.9
1.62
– – – – – – – – – – – – – – – – – – – – – – – –
2.3
2.77
3.32
4.05
4.55
4.68
2.59
3.09
3.81
4.32
Total
2.3
(1.4-3.0)
2.5
(1.4-3.3)
3.4
(1.5-4.3)
5.0
(1.6-5.6)
6.0
(1.6-6.6)
7.1
(1.7-7.4)
4.6
(2.0-5.4)
4.8
(2.0-5.8)
5.7
(2.0-6.6)
7.2
(2.0-7.7)
7.2
(2.0-8.0)
7.2
(2.0-8.2)
5.0
(2.0-6.2)
5.9
(2.0-7.3)
7.2
(2.0-8.5)
7.2
(2.0-8.5)
7.2
(2.0-8.5)
6.8
(2.0-8.5)
7.2
(2.0-8.5)
7.2
(2.0-8.5)
7.2
(2.0-8.5)
7.2
(2.1-8.5)
7.2
(2.1-8.5)
7.2
(2.1-8.5)
6.9
(2.9-8.1)
7.1
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
11
NOTE: Electrical data is for outdoor unit only.
Outdoor unit
power consumption
(kW)
0.710
(0.400-0.920)
0.760
(0.400-1.010)
1.000
(0.400-1.290)
1.440
(0.420-1.630)
1.930
(0.400-2.130)
2.580
(0.410-2.710)
1.180
(0.600-1.600)
1.300
(0.600-1.770)
1.710
(0.600-2.200)
2.400
(0.560-2.710)
2.360
(0.560-3.050)
2.360
(0.560-3.200)
1.360
(0.580-1.950)
1.860
(0.580-2.670)
2.400
(0.560-3.200)
2.360
(0.560-3.170)
2.360
(0.560-3.170)
2.330
(0.580-3.260)
2.390
(0.560-3.210)
2.350
(0.560-3.180)
2.350
(0.560-3.180)
2.340
(0.590-3.160)
2.300
(0.570-3.110)
2.300
(0.570-3.110)
1.940
(0.690-2.410)
2.030
(0.690-2.510)
2.310
(0.690-2.620)
2.320
(0.700-2.570)
2.370
(0.680-2.530)
2.390
(0.680-2.530)
2.130
(0.690-2.620)
2.350
(0.690-2.620)
2.370
(0.700-2.570)
2.390
(0.680-2.530)
Current
(A)
3.12
3.34
4.39
6.32
8.48
11.33
5.18
5.71
7.51
10.54
10.36
10.36
5.97
8.17
10.54
10.36
10.36
10.23
10.50
10.32
10.32
10.28
10.10
10.10
8.52
8.92
10.14
10.19
10.41
10.50
9.35
10.32
10.41
10.50
Power
factor
(%)
99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99
07+09+26 07+12+12 07+12+18 07+12+24 07+12+26 07+18+18 07+18+24 07+18+26 09+09+09 09+09+12 09+09+18 09+09+24 09+09+26 09+12+12 09+12+18 09+12+24 09+12+26 09+18+18 09+18+24 12+12+12 12+12+18 12+12+24 12+12+26 12+18+18 12+18+24
Indoor units combination
Unit A Unit B Unit C
Cooling capacity (kW)
Total
Outdoor unit
power consumption
(kW)
Current
(A)
Power
factor
(%)
NOTE: Electrical data is for outdoor unit only.
99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99
10.50
10.32
10.19
10.32
10.32
10.23
10.10
10.10
8.92
10.32
10.41
10.50
10.50
10.32
10.45
10.32
10.32
10.23
10.10
9.18
10.01
9.93
9.93
9.84
9.75
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.1
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
7.2
(2.9-8.5)
2.390
(0.680-2.530)
2.350
(0.690-2.570)
2.320
(0.700-2.540)
2.350
(0.680-2.520)
2.350
(0.680-2.520)
2.330
(0.680-2.520)
2.300
(0.660-2.490)
2.300
(0.660-2.490)
2.030
(0.690-2.650)
2.350
(0.690-2.620)
2.370
(0.700-2.570)
2.390
(0.680-2.530)
2.390
(0.680-2.530)
2.350
(0.690-2.570)
2.380
(0.700-2.540)
2.350
(0.680-2.520)
2.350
(0.680-2.520)
2.330
(0.660-2.500)
2.300
(0.660-2.500)
2.090
(0.720-2.560)
2.280
(0.700-2.530)
2.260
(0.680-2.500)
2.260
(0.680-2.500)
2.240
(0.680-2.500)
2.220
(0.660-2.470)
1.54
2.79
2.33
2.0
1.92
3.01
2.64
2.54
2.36
2.16
1.8
1.54
1.47
2.61
2.21
1.92
1.83
2.88
2.54
2.4
2.05
1.8
1.72
2.7
2.4
4.45
2.79
3.5
4.01
4.16
3.01
3.52
3.67
2.36
2.89
3.6
4.11
4.25
2.61
3.32
3.84
3.98
2.88
3.38
2.4
3.08
3.6
3.74
2.7
3.2
1.2
1.62
1.36
1.17
1.12
1.17
1.02
0.98
2.36
2.16
1.8
1.54
1.47
1.97
1.66
1.44
1.37
1.44
1.27
2.4
2.05
1.8
1.72
1.8
1.6
12
Indoor units combination
07
09
12
18
24
26 07+07 07+09 07+12 07+18 07+24 07+26 09+09 09+12 09+18 09+24 09+26 12+12 12+18 12+24 12+26 18+18 18+24 18+26
07+07+07 07+07+09 07+07+12 07+07+18 07+07+24 07+07+26 07+09+09 07+09+12 07+09+18 07+09+24
Heating capacity (kW)
Unit A Unit B Unit C
3.3
3.6
4.0
7.2
7.9
8.6
3.3
3.02
2.69
2.49
2.03
1.91
3.6
3.26
3.0
2.45
2.31
4.0
3.6
3.0
2.84
4.5
3.86
3.68
2.9
2.67
2.42
1.96
1.65
1.57
2.52
2.25
1.85
1.57
– – – – – –
3.3
3.88
4.61
6.41
6.97
7.09
3.6
4.34
6.0
6.55
6.69
4.0
5.4
6.0
6.16
4.5
5.14
5.32
2.9
2.67
2.42
1.96
1.65
1.57
3.24
2.89
2.38
2.02
– – – – – – – – – – – – – – – – – – – – – – – –
2.9
3.44
4.15
5.06
5.68
5.85
3.24
3.85
4.76
5.4
Total
3.3
(1.2-4.2)
3.6
(1.2-4.5)
4.0
(1.2-4.8)
7.2
(1.4-8.2)
7.9
(1.4-8.6)
8.6
(1.6-9.2)
6.6
(1.8-7.2)
6.9
(1.8-8.7)
7.3
(1.8-9.2)
8.9
(1.8-9.9)
9.0
(1.8-9.9)
9.0
(1.8-9.9)
7.2
(1.8-9.1)
7.6
(1.8-9.5)
9.0
(1.8-10.1)
9.0
(1.8-10.1)
9.0
(1.8-10.1)
8.0
(1.8-9.8)
9.0
(1.8-10.5)
9.0
(1.8-10.5)
9.0
(1.8-10.5)
9.0
(1.9-11.0)
9.0
(1.9-11.0)
9.0
(1.9-11.0)
8.7
(2.6-10.6)
8.8
(2.6-11.0)
9.0
(2.6-11.0)
9.0
(2.6-11.0)
9.0
(2.6-11.0)
9.0
(2.6-11.0)
9.0
(2.6-11.0)
9.0
(2.6-11.0)
9.0
(2.6-11.0)
9.0
(2.6-11.0)
13
NOTE: Electrical data is for outdoor unit only.
Outdoor unit
power consumption
(kW)
1.050
(0.340-1.380)
1.110
(0.340-1.510)
1.210
(0.330-1.570)
2.270
(0.330-2.710)
2.700
(0.330-3.060)
3.220
(0.360-3.520)
2.020
(0.480-2.760)
2.120
(0.480-3.000)
2.130
(0.480-3.110)
2.470
(0.460-3.140)
2.520
(0.460-3.140)
2.520
(0.460-3.140)
2.170
(0.480-3.140)
2.210
(0.480-3.230)
2.520
(0.460-3.260)
2.500
(0.460-3.260)
2.500
(0.460-3.260)
2.370
(0.480-3.230)
2.500
(0.460-3.420)
2.480
(0.460-3.420)
2.480
(0.460-3.420)
2.210
(0.440-3.260)
2.210
(0.440-3.260)
2.210
(0.440-3.260)
2.150
(0.530-3.150)
2.170
(0.530-3.170)
2.200
(0.530-3.190)
2.040
(0.510-3.040)
2.040
(0.510-3.040)
2.040
(0.510-3.040)
2.200
(0.530-3.260)
2.180
(0.530-3.180)
2.020
(0.510-3.040)
2.020
(0.510-3.040)
Current
(A)
4.61
4.87
5.31
9.97
11.86
14.14
8.87
9.31
9.35
10.85
11.07
11.07
9.53
9.71
11.07
10.98
10.98
10.41
10.98
10.89
10.89
9.71
9.71
9.71
9.44
9.53
9.66
8.96
8.96
8.96
9.66
9.57
8.87
8.87
Power
factor
(%)
99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99
07+09+26 07+12+12 07+12+18 07+12+24 07+12+26 07+18+18 07+18+24 07+18+26 09+09+09 09+09+12 09+09+18 09+09+24 09+09+26 09+12+12 09+12+18 09+12+24 09+12+26 09+18+18 09+18+24 12+12+12 12+12+18 12+12+24 12+12+26 12+18+18 12+18+24
Indoor units
combination
Unit A Unit B Unit C
Heating capacity (kW)
Total
Outdoor unit
power consumption
(kW)
Current
(A)
Power
factor
(%)
NOTE: Electrical data is for outdoor unit only.
99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99
8.87
9.57
8.52
8.52
8.52
8.12
8.12
8.12
9.53
9.49
8.78
8.78
8.78
9.49
8.43
8.43
8.43
8.04
8.04
9.44
8.30
8.30
8.30
7.91
7.91
9.0
(2.6-11.0)
9.0
(2.6-11.0)
9.0
(2.7-11.0)
9.0
(2.7-11.0)
9.0
(2.7-11.0)
9.0
(2.7-11.0)
9.0
(2.7-11.0)
9.0
(2.7-11.0)
9.0
(2.6-11.0)
9.0
(2.6-11.0)
9.0
(2.6-11.0)
9.0
(2.6-11.0)
9.0
(2.6-11.0)
9.0
(2.6-11.0)
9.0
(2.7-11.0)
9.0
(2.7-11.0)
9.0
(2.7-11.0)
9.0
(2.7-11.0)
9.0
(2.7-11.0)
9.0
(2.6-11.0)
9.0
(2.7-11.0)
9.0
(2.7-11.0)
9.0
(2.7-11.0)
9.0
(2.7-11.0)
9.0
(2.7-11.0)
2.020
(0.510-3.040)
2.180
(0.530-3.150)
1.940
(0.510-2.950)
1.940
(0.510-2.950)
1.940
(0.510-2.950)
1.850
(0.490-2.830)
1.850
(0.490-2.830)
1.850
(0.490-2.830)
2.170
(0.530-3.230)
2.160
(0.530-3.180)
2.000
(0.510-3.030)
2.000
(0.510-3.030)
2.000
(0.510-3.030)
2.160
(0.530-3.150)
1.920
(0.510-2.950)
1.920
(0.510-2.950)
1.920
(0.510-2.950)
1.830
(0.490-2.830)
1.830
(0.490-2.830)
2.150
(0.530-3.050)
1.890
(0.510-2.890)
1.890
(0.510-2.890)
1.890
(0.510-2.890)
1.800
(0.490-2.770)
1.800
(0.490-2.770)
1.92
3.48
2.91
2.51
2.4
3.76
3.3
3.17
3.0
2.7
2.25
1.92
1.84
3.27
2.76
2.4
2.29
3.6
3.17
3.0
2.57
2.25
2.16
3.37
3.0
5.57
3.48
4.37
5.02
5.2
3.76
4.4
4.58
3.0
3.6
4.5
5.14
5.31
3.27
4.15
4.8
4.97
3.6
4.23
3.0
3.85
4.5
4.68
3.37
4.0
1.5
2.03
1.7
1.46
1.4
1.46
1.28
1.23
3.0
2.7
2.25
1.92
1.84
2.45
2.07
1.8
1.72
1.8
1.58
3.0
2.57
2.25
2.16
2.25
2.0
14
MXZ-A32WV -
Indoor units
combination
07
09
12
18
24
26 07+07 07+09 07+12 07+18 07+24 07+26 09+09 09+12 09+18 09+24 09+26 12+12 12+18 12+24 12+26 18+18 18+24 18+26 24+24 24+26
07+07+07 07+07+09 07+07+12 07+07+18 07+07+24 07+07+26 07+09+09 07+09+12
E1
Cooling capacity (kW)
Unit A Unit B Unit C Unit D
2.3
2.5
3.4
5.0
6.0
7.1
2.3
2.1
2.1
2.04
1.75
1.66
2.5
2.52
2.5
2.11
2.01
3.4
3.1
2.61
2.51
3.95
3.42
3.27
4.0
3.84
2.3
2.16
2.07
1.72
1.46
1.4
2.04
1.93
– – – – – –
2.3
2.7
3.6
5.25
6.0
6.19
2.5
3.37
5.0
5.64
5.84
3.4
4.65
5.24
5.44
3.95
4.57
4.72
4.0
4.16
2.3
2.16
2.07
1.72
1.46
1.4
2.62
2.49
– – – – – – – – – – – – – – – – – – – – – – – – – –
2.3
2.77
3.55
4.41
5.03
5.2
2.62
3.33
NOTE: Electrical data is for outdoor unit only.
Outdoor unit
Total
– – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – –
15
2.3
(1.4-3.0)
2.5
(1.4-3.3)
3.4
(1.5-4.3)
5.0
(1.6-5.6)
6.0
(1.6-6.6)
7.1
(1.7-7.4)
4.6
(2.0-5.4)
4.8
(2.0-5.8)
5.7
(2.0-6.6)
7.3
(2.0-7.7)
7.75
(2.0-8.0)
7.85
(2.0-8.2)
5.0
(2.0-6.2)
5.9
(2.0-7.3)
7.5
(2.0-8.5)
7.75
(2.0-8.6)
7.85
(2.0-8.7)
6.8
(2.0-8.8)
7.75
(2.0-8.8)
7.85
(2.0-8.8)
7.95
(2.0-8.8)
7.9
(2.1-8.8)
8.0
(2.1-8.8)
8.0
(2.1-8.8)
8.0
(2.1-8.8)
8.0
(2.1-8.8)
6.9
(2.9-8.1)
7.1
(2.9-8.6)
7.7
(2.9-9.0)
7.85
(2.9-9.0)
7.95
(2.9-9.0)
8.0
(2.9-9.0)
7.3
(2.9-8.9)
7.75
(2.9-9.0)
power consumption
(kW)
0.710
(0.400-0.920)
0.760
(0.400-1.010)
1.000
(0.400-1.290)
1.440
(0.420-1.630)
1.930
(0.400-2.130)
2.580
(0.410-2.710)
1.180
(0.600-1.600)
1.300
(0.600-1.770)
1.710
(0.600-2.200)
2.480
(0.560-2.710)
2.750
(0.560-3.050)
2.810
(0.560-3.200)
1.360
(0.580-1.950)
1.860
(0.580-2.670)
2.580
(0.560-3.200)
2.750
(0.560-3.280)
2.810
(0.560-3.320)
2.330
(0.580-3.270)
2.760
(0.560-3.220)
2.730
(0.560-3.180)
2.780
(0.560-3.180)
2.780
(0.590-3.160)
2.800
(0.570-3.120)
2.800
(0.570-3.120)
2.690
(0.550-3.080)
2.690
(0.550-3.080)
1.940
(0.690-2.410)
2.030
(0.690-2.720)
2.310
(0.690-2.970)
2.320
(0.700-2.920)
2.370
(0.680-2.880)
2.390
(0.680-2.880)
2.130
(0.690-2.940)
2.350
(0.690-2.970)
Current
(A)
3.12
3.34
4.39
6.32
8.48
11.33
5.18
5.71
7.51
10.89
12.08
12.34
5.97
8.17
11.33
12.08
12.34
10.23
12.12
11.99
12.21
12.21
12.30
12.30
11.81
11.81
8.52
8.92
10.14
10.19
10.41
10.50
9.35
10.32
Power
factor
(%)
99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99
Indoor units
combination
Unit A Unit B Unit C Unit D
Cooling capacity (kW)
Total
Outdoor unit
power consumption
(kW)
Current
(A)
Power
factor
(%)
NOTE: Electrical data is for outdoor unit only.
07+09+18 07+09+24 07+09+26 07+12+12 07+12+18 07+12+24 07+12+26 07+18+18 07+18+24 07+18+26 09+09+09 09+09+12 09+09+18 09+09+24 09+09+26 09+12+12 09+12+18 09+12+24 09+12+26 09+18+18 09+18+24 12+12+12 12+12+18 12+12+24 12+12+26 12+18+18
12+18+24 07+07+07+07 07+07+07+09 07+07+07+12 07+07+07+18 07+07+07+24 07+07+07+26 07+07+09+09
99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99
10.41
10.50
10.50
10.32
10.19
10.32
10.32
10.23
10.10
10.10
8.92
10.32
10.41
10.50
10.50
10.32
10.45
10.32
10.32
10.23
10.10
10.01
10.01
9.93
9.93
9.84
9.75
9.57
9.62
9.71
9.44
9.35
9.35
9.62
7.9
(2.9-9.0)
8.0
(2.9-9.0)
8.0
(2.9-9.0)
7.85
(2.9-9.0)
7.9
(2.9-9.0)
8.0
(2.9-9.0)
8.0
(2.9-9.0)
8.0
(2.9-9.0)
8.0
(2.9-9.0)
8.0
(2.9-9.0)
7.1
(2.9-9.0)
7.75
(2.9-9.0)
7.9
(2.9-9.0)
8.0
(2.9-9.0)
8.0
(2.9-9.0)
7.85
(2.9-9.0)
8.0
(2.9-9.0)
8.0
(2.9-9.0)
8.0
(2.9-9.0)
8.0
(2.9-9.0)
8.0
(2.9-9.0)
7.95
(2.9-9.0)
8.0
(2.9-9.0)
8.0
(2.9-9.0)
8.0
(2.9-9.0)
8.0
(2.9-9.0)
8.0
(2.9-9.0)
7.8
(3.7-9.2)
7.85
(3.7-9.2)
7.95
(3.7-9.2)
8.0
(3.7-9.2)
8.0
(3.7-9.2)
8.0
(3.7-9.2)
7.85
(3.7-9.2)
2.370
(0.700-2.920)
2.390
(0.680-2.880)
2.390
(0.680-2.880)
2.350
(0.690-2.920)
2.320
(0.700-2.890)
2.350
(0.680-2.860)
2.350
(0.680-2.860)
2.330
(0.680-2.860)
2.300
(0.660-2.830)
2.300
(0.660-2.830)
2.030
(0.690-3.010)
2.350
(0.690-2.970)
2.370
(0.700-2.920)
2.390
(0.680-2.880)
2.390
(0.680-2.880)
2.350
(0.690-2.920)
2.380
(0.700-2.890)
2.350
(0.680-2.860)
2.350
(0.680-2.860)
2.330
(0.660-2.840)
2.300
(0.660-2.830)
2.280
(0.720-2.910)
2.280
(0.700-2.870)
2.260
(0.680-2.840)
2.260
(0.680-2.840)
2.240
(0.680-2.840)
2.220
(0.660-2.810)
2.180
(0.810-2.670)
2.190
(0.810-2.670)
2.210
(0.810-2.650)
2.150
(0.790-2.620)
2.130
(0.770-2.590)
2.130
(0.770-2.590)
2.190
(0.810-2.670)
2.09
1.8
1.71
3.04
2.56
2.23
2.13
3.34
2.93
2.82
2.36
2.32
1.97
1.71
1.63
2.85
2.46
2.13
2.04
3.2
2.82
2.65
2.28
2.0
1.92
3.0
2.66
1.95
1.83
1.68
1.43
1.24
1.19
1.72
4.18
4.8
4.95
3.04
3.84
4.46
4.62
3.34
3.91
4.07
2.36
3.11
3.95
4.57
4.72
2.85
3.69
4.26
4.42
3.2
3.76
2.65
3.42
4.0
4.16
3.0
3.55
1.95
1.83
1.68
1.43
1.24
1.19
2.2
– – – – – – – – – – – – – – – – – – – – – – – – – – –
1.95
2.36
2.91
3.69
4.26
4.42
2.2
1.62
1.4
1.33
1.77
1.49
1.3
1.24
1.3
1.14
1.09
2.36
2.32
1.97
1.71
1.63
2.15
1.84
1.6
1.53
1.6
1.41
2.65
2.28
2.0
1.92
2.0
1.77
1.95
1.83
1.68
1.43
1.24
1.19
1.72
16
Indoor units
combination 07+07+09+12 07+07+09+18 07+07+09+24 07+07+09+26 07+07+12+12 07+07+12+18 07+07+12+24 07+07+18+18 07+09+09+09 07+09+09+12 07+09+09+18 07+09+09+24 07+09+12+12 07+09+12+18 07+09+12+24 07+12+12+12 07+12+12+18 09+09+09+09 09+09+09+12 09+09+09+18 09+09+09+24 09+09+12+12 09+09+12+18 09+12+12+12 12+12+12+12
Cooling capacity (kW)
Unit A Unit B Unit C Unit D
1.59
1.36
1.19
1.14
1.47
1.27
1.12
1.12
1.62
1.5
1.3
1.14
1.4
1.21
1.07
1.3
1.14
1.97
1.84
1.6
1.41
1.56
1.5
1.6
2.0
1.59
1.36
1.19
1.14
1.47
1.27
1.12
1.12
2.09
1.93
1.67
1.46
1.8
1.56
1.38
2.23
1.95
1.97
1.84
1.6
1.41
1.75
1.5
2.13
2.0
2.04
1.75
1.53
1.46
2.52
2.18
1.92
2.88
2.09
1.93
1.67
1.46
2.4
2.08
1.84
2.23
1.95
1.97
1.84
1.6
1.41
2.34
2.0
2.13
2.0
2.72
3.51
4.08
4.24
2.52
3.27
3.84
2.88
2.09
2.59
3.34
3.91
2.4
3.13
3.69
2.23
2.93
1.97
2.46
3.2
3.76
2.34
3.0
2.13
2.0
Total
7.95
(3.7-9.2)
8.0
(3.7-9.2)
8.0
(3.7-9.2)
8.0
(3.7-9.2)
8.0
(3.7-9.2)
8.0
(3.7-9.2)
8.0
(3.7-9.2)
8.0
(3.7-9.2)
7.9
(3.7-9.2)
7.95
(3.7-9.2)
8.0
(3.7-9.2)
8.0
(3.7-9.2)
8.0
(3.7-9.2)
8.0
(3.7-9.2)
8.0
(3.7-9.2)
8.0
(3.7-9.2)
8.0
(3.7-9.2)
7.9
(3.7-9.2)
8.0
(3.7-9.2)
8.0
(3.7-9.2)
8.0
(3.7-9.2)
8.0
(3.7-9.2)
8.0
(3.7-9.2)
8.0
(3.7-9.2)
8.0
(3.7-9.2)
NOTE: Electrical data is for outdoor unit only.
Outdoor unit
power consumption
(kW)
2.210
(0.810-2.650)
2.150
(0.790-2.620)
2.130
(0.770-2.590)
2.130
(0.770-2.590)
2.210
(0.810-2.620)
2.120
(0.790-2.590)
2.100
(0.770-2.560)
2.070
(0.770-2.560)
2.140
(0.810-2.670)
2.210
(0.810-2.650)
2.150
(0.790-2.620)
2.130
(0.770-2.590)
2.210
(0.810-2.620)
2.120
(0.790-2.590)
2.100
(0.770-2.560)
2.200
(0.810-2.610)
2.080
(0.790-2.580)
2.140
(0.810-2.670)
2.220
(0.810-2.650)
2.150
(0.790-2.620)
2.130
(0.770-2.590)
2.210
(0.810-2.620)
2.120
(0.790-2.590)
2.200
(0.810-2.610)
2.190
(0.810-2.580)
Current
(A)
9.71
9.44
9.35
9.35
9.71
9.31
9.22
9.09
9.40
9.71
9.44
9.35
9.71
9.31
9.22
9.66
9.13
9.40
9.75
9.44
9.35
9.71
9.31
9.66
9.62
Power
factor
(%)
99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99
17
Indoor units combination
Unit A Unit B Unit C Unit D
Heating capacity (kW)
Total
Outdoor unit
power consumption
(kW)
Current
(A)
Power
factor
(%)
NOTE: Electrical data is for outdoor unit only.
07 09 12 18 24
26 07+07 07+09 07+12 07+18 07+24 07+26 09+09 09+12 09+18 09+24 09+26 12+12 12+18 12+24 12+26 18+18 18+24 18+26 24+24 24+26
07+07+07 07+07+09 07+07+12 07+07+18 07+07+24 07+07+26 07+09+09 07+09+12
99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99
4.61
4.87
5.31
9.97
11.86
14.14
8.87
9.31
9.35
10.85
11.90
11.90
9.53
9.71
11.07
11.90
11.90
10.41
11.24
11.24
11.24
10.41
10.41
10.41
10.41
10.41
9.44
9.53
10.14
9.31
9.31
9.31
9.53
9.97
3.3
(1.2-4.2)
3.6
(1.2-4.5)
4.0
(1.2-4.8)
7.2
(1.4-8.2)
7.9
(1.4-8.6)
8.6
(1.6-9.2)
6.6
(1.8-7.2)
6.9
(1.8-8.7)
7.3
(1.8-9.2)
8.9
(1.8-9.9)
9.4
(1.8-9.9)
9.4
(1.8-9.9)
7.2
(1.8-9.1)
7.6
(1.8-9.5)
9.0
(1.8-10.1)
9.4
(1.8-10.1)
9.4
(1.8-10.1)
8.0
(1.8-9.8)
9.4
(1.8-10.5)
9.4
(1.8-10.5)
9.4
(1.8-10.5)
9.4
(1.9-11.2)
9.4
(1.9-11.2)
9.4
(1.9-11.2)
9.4
(1.9-11.2)
9.4
(1.9-11.2)
8.7
(2.6-10.6)
8.8
(2.6-11.1)
9.4
(2.6-11.6)
9.4
(2.6-11.6)
9.4
(2.6-11.6)
9.4
(2.6-11.6)
8.9
(2.6-11.6)
9.4
(2.6-11.6)
1.050
(0.340-1.380)
1.110
(0.340-1.510)
1.210
(0.330-1.570)
2.270
(0.330-2.710)
2.700
(0.330-3.060)
3.220
(0.360-3.520)
2.020
(0.480-2.760)
2.120
(0.480-3.000)
2.130
(0.480-3.110)
2.470
(0.460-3.140)
2.710
(0.460-3.140)
2.710
(0.460-3.140)
2.170
(0.480-3.140)
2.210
(0.480-3.230)
2.520
(0.460-3.260)
2.710
(0.460-3.260)
2.710
(0.460-3.260)
2.370
(0.480-3.230)
2.560
(0.460-3.420)
2.560
(0.460-3.420)
2.560
(0.460-3.420)
2.370
(0.440-3.320)
2.370
(0.440-3.320)
2.370
(0.440-3.320)
2.370
(0.440-3.320)
2.370
(0.440-3.320)
2.150
(0.530-3.060)
2.170
(0.530-3.330)
2.310
(0.530-3.400)
2.120
(0.510-3.330)
2.120
(0.510-3.330)
2.120
(0.510-3.330)
2.170
(0.530-3.420)
2.270
(0.530-3.410)
– – – – – –
3.3
3.88
4.61
6.41
7.28
7.41
3.6
4.34
6.0
6.84
6.98
4.0
5.64
6.27
6.43
4.7
5.37
5.55
4.7
4.89
2.9
2.67
2.53
2.05
1.73
1.64
3.2
3.02
– – – – – – – – – – – – – – – – – – – – – – – – – –
2.9
3.44
4.33
5.28
5.93
6.11
3.2
4.02
– – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – –
3.3
3.6
4.0
7.2
7.9
8.6
3.3
3.02
2.69
2.49
2.12
1.99
3.6
3.26
3.0
2.56
2.42
4.0
3.76
3.13
2.97
4.7
4.03
3.85
4.7
4.51
2.9
2.67
2.53
2.05
1.73
1.64
2.49
2.35
18
Indoor units combination
07+09+18 07+09+24 07+09+26 07+12+12 07+12+18 07+12+24 07+12+26 07+18+18 07+18+24 07+18+26 09+09+09 09+09+12 09+09+18 09+09+24 09+09+26 09+12+12 09+12+18 09+12+24 09+12+26 09+18+18 09+18+24 12+12+12 12+12+18 12+12+24 12+12+26 12+18+18
12+18+24 07+07+07+07 07+07+07+09 07+07+07+12 07+07+07+18 07+07+07+24 07+07+07+26 07+07+09+09
Heating capacity (kW)
Unit A Unit B Unit C Unit D
1.93
1.64
1.56
2.12
1.77
1.53
1.46
1.53
1.34
1.29
3.0
2.82
2.35
2.01
1.92
2.56
2.16
1.88
1.8
1.88
1.65
3.13
2.68
2.35
2.25
2.35
2.08
2.35
2.19
1.99
1.68
1.46
1.4
2.05
2.48
2.11
2.01
3.63
3.04
2.62
2.5
3.93
3.45
3.31
3.0
2.82
2.35
2.01
1.92
3.41
2.89
2.5
2.4
3.76
3.31
3.13
2.68
2.35
2.25
3.52
3.13
2.35
2.19
1.99
1.68
1.46
1.4
2.05
4.97
5.64
5.81
3.63
4.57
5.24
5.43
3.93
4.6
4.79
3.0
3.76
4.7
5.37
5.55
3.41
4.33
5.01
5.2
3.76
4.42
3.13
4.02
4.7
4.88
3.52
4.17
2.35
2.19
1.99
1.68
1.46
1.4
2.64
– – – – – – – – – – – – – – – – – – – – – – – – – – –
2.35
2.82
3.41
4.33
5.01
5.2
2.64
19
Total
9.4
(2.6-11.6)
9.4
(2.6-11.6)
9.4
(2.6-11.6)
9.4
(2.6-11.6)
9.4
(2.7-11.6)
9.4
(2.7-11.6)
9.4
(2.7-11.6)
9.4
(2.7-11.6)
9.4
(2.7-11.6)
9.4
(2.7-11.6)
9.0
(2.6-11.6)
9.4
(2.6-11.6)
9.4
(2.6-11.6)
9.4
(2.6-11.6)
9.4
(2.6-11.6)
9.4
(2.6-11.6)
9.4
(2.7-11.6)
9.4
(2.7-11.6)
9.4
(2.7-11.6)
9.4
(2.7-11.6)
9.4
(2.7-11.6)
9.4
(2.6-11.6)
9.4
(2.7-11.6)
9.4
(2.7-11.6)
9.4
(2.7-11.6)
9.4
(2.7-11.6)
9.4
(2.7-11.6)
9.4
(3.4-11.6)
9.4
(3.4-11.6)
9.4
(3.4-11.6)
9.4
(3.5-11.6)
9.4
(3.5-11.6)
9.4
(3.5-11.6)
9.4
(3.4-11.6)
NOTE: Electrical data is for outdoor unit only.
Outdoor unit
power consumption
(kW)
2.100
(0.510-3.330)
2.100
(0.510-3.330)
2.100
(0.510-3.330)
2.210
(0.530-3.400)
2.050
(0.510-3.230)
2.050
(0.510-3.230)
2.050
(0.510-3.230)
1.960
(0.490-3.100)
1.960
(0.490-3.100)
1.960
(0.490-3.100)
2.170
(0.530-3.420)
2.250
(0.530-3.410)
2.090
(0.510-3.320)
2.090
(0.510-3.320)
2.090
(0.510-3.320)
2.190
(0.530-3.400)
2.030
(0.510-3.230)
2.030
(0.510-3.230)
2.030
(0.510-3.230)
1.940
(0.490-3.100)
1.940
(0.490-3.100)
2.170
(0.530-3.380)
2.010
(0.510-3.160)
2.010
(0.510-3.160)
2.010
(0.510-3.160)
1.920
(0.490-3.030)
1.920
(0.490-3.030)
2.020
(0.590-3.420)
1.990
(0.590-3.410)
1.960
(0.590-3.390)
1.910
(0.580-3.260)
1.910
(0.580-3.260)
1.910
(0.580-3.260)
1.980
(0.590-3.400)
Current
(A)
9.22
9.22
9.22
9.71
9.00
9.00
9.00
8.61
8.61
8.61
9.53
9.88
9.18
9.18
9.18
9.62
8.92
8.92
8.92
8.52
8.52
9.53
8.83
8.83
8.83
8.43
8.43
8.87
8.74
8.61
8.39
8.39
8.39
8.70
Power
factor
(%)
99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99
Indoor units
combination
Unit A Unit B Unit C Unit D
Heating capacity (kW)
Total
Outdoor unit
power consumption
(kW)
Current
(A)
Power
factor
(%)
NOTE: Electrical data is for outdoor unit only.
07+07+09+12 07+07+09+18 07+07+09+24 07+07+09+26 07+07+12+12 07+07+12+18 07+07+12+24 07+07+18+18 07+09+09+09 07+09+09+12 07+09+09+18 07+09+09+24 07+09+12+12 07+09+12+18 07+09+12+24 07+12+12+12 07+12+12+18 09+09+09+09 09+09+09+12 09+09+09+18 09+09+09+24 09+09+12+12 09+09+12+18 09+12+12+12 12+12+12+12
99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99
8.52
8.30
8.30
8.30
8.39
7.99
7.99
7.69
8.61
8.43
8.21
8.21
8.30
7.91
7.91
8.17
7.82
8.56
8.39
8.17
8.17
8.21
7.82
8.08
8.48
9.4
(3.4-11.6)
9.4
(3.5-11.6)
9.4
(3.5-11.6)
9.4
(3.5-11.6)
9.4
(3.4-11.6)
9.4
(3.5-11.6)
9.4
(3.5-11.6)
9.4
(3.4-11.6)
9.4
(3.4-11.6)
9.4
(3.4-11.6)
9.4
(3.5-11.6)
9.4
(3.5-11.6)
9.4
(3.4-11.6)
9.4
(3.5-11.6)
9.4
(3.5-11.6)
9.4
(3.4-11.6)
9.4
(3.5-11.6)
9.4
(3.4-11.6)
9.4
(3.4-11.6)
9.4
(3.5-11.6)
9.4
(3.5-11.6)
9.4
(3.4-11.6)
9.4
(3.5-11.6)
9.4
(3.4-11.6)
9.4
(3.4-11.6)
1.940
(0.590-3.390)
1.890
(0.580-3.270)
1.890
(0.580-3.270)
1.890
(0.580-3.270)
1.910
(0.590-3.340)
1.820
(0.580-3.220)
1.820
(0.580-3.220)
1.750
(0.550-3.130)
1.960
(0.590-3.390)
1.920
(0.590-3.370)
1.870
(0.580-3.230)
1.870
(0.580-3.230)
1.890
(0.590-3.320)
1.800
(0.580-3.200)
1.800
(0.580-3.200)
1.860
(0.590-3.280)
1.780
(0.580-3.210)
1.950
(0.590-3.390)
1.910
(0.590-3.350)
1.860
(0.580-3.210)
1.860
(0.580-3.210)
1.870
(0.590-3.300)
1.780
(0.580-3.190)
1.840
(0.590-3.260)
1.930
(0.590-3.230)
1.88
1.6
1.4
1.34
1.73
1.49
1.31
1.31
2.48
2.28
1.96
1.72
2.11
1.83
1.62
2.62
2.3
2.35
2.16
1.88
1.65
2.06
1.76
2.5
2.35
2.41
2.06
1.8
1.72
2.96
2.56
2.25
3.38
2.48
2.28
1.96
1.72
2.82
2.45
2.16
2.62
2.3
2.35
2.16
1.88
1.65
2.75
2.35
2.5
2.35
3.22
4.12
4.8
4.98
2.96
3.84
4.51
3.38
2.48
3.04
3.93
4.6
2.82
3.67
4.33
2.62
3.45
2.35
2.89
3.76
4.42
2.75
3.52
2.5
2.35
1.88
1.6
1.4
1.34
1.73
1.49
1.31
1.31
1.93
1.77
1.53
1.34
1.64
1.43
1.26
1.53
1.34
2.35
2.16
1.88
1.65
1.83
1.76
1.88
2.35
20
5
Outdoor model
Indoor units number Piping total length Connecting pipe length Height difference (Indoor ~ Outdoor) Height difference (Indoor ~ Indoor) Function Capacity [Rated (Min.~Max.) Hz]1 Dehumidification Outdoor air flow Power outlet Running current 1 Power input Auxiliary heater Crankcase heater Power factor 1 Starting current 1 Compressor motor current Fan motor current
Model Output Winding resistance (at 20:) Model Winding resistance (at 20:) Dimensions WOHOD Weight Sound level (High/Low ) 3 Fan speed (High/Low ) 3 Fan speed regulator 3 Refrigerant filling capacity (R410A) Refrigeration oil (Model) Thermistor RT61 Thermistor RT62 Thermistor RT63 Thermistor RT6A,6B Thermistor RT65 Thermistor RT68
m m m m
kW
R/h
K /h
A A
W
A(kW)
W %
A A A
W
"
  
"
mm
kg
dB
rpm
kg cc
k" k" k" k" k" k"
Compressor
2 Electrical
data
Fan
motor
Special
remarks
Capacity System
Coefficient of performance (C.O.P)
Outdoor unit power supply
MXZ-A14WV -
E1
MXZ-A14WV -
E2
Single phase
230V,50Hz
2
Max. 30 (chargeless 20)
Max. 20
10 10
2,460
20
— —
90.0
5.55
0.57
SNV-092FJYH (ROTARY)
1,100
U-V 2.56
V-W 2.56 W-U 2.56
RA6V49
WHT-BLK 139.9 BLK-YLW 34.2
BLK-RED 205.3
840(+69)o640o330
52
725/620
2
1.75
450 (NEO22)
13.4 (at 100:)
10.0 (at 25:)
10.0 (at 25:)
10.0 (at 25:)
17.0 (at 50:)
10.0 (at 25:)
Cooling
4.0 (1.53~4.5) —
5.55
1,150 (370~1,330)
4.98
3.48
48/44
Heating
4.5 (1.56~5.0) —
5.12
1,060 (300~1,190)
4.55
4.25
49/45
w
w
w w
w
MXZ-A18WV -
E1
MXZ-A18WV -
E2
Single phase
230V,50Hz
2
Max. 30 (chargeless 20)
Max. 20
10 10
2,460
20
— —
90.0
8.98
0.57
SNV-092FJYH (ROTARY)
1,450
U-V 2.56
V-W 2.56 W-U 2.56
RA6V49
WHT-BLK 139.9 BLK-YLW 34.2
BLK-RED 205.3
840(+69)o640o330
52
725/620
2
1.75
450 (NEO22)
13.4 (at 100:)
10.0 (at 25:)
10.0 (at 25:)
10.0 (at 25:)
17.0 (at 50:)
10.0 (at 25:)
Cooling
5.4 (1.55~6.0) —
8.98
1,860 (370~2,130)
8.41
2.90
49/44
Heating
6.6 (1.58~7.2) —
8.55
1,770 (290~1,850)
7.98
3.73
50/45
w w
w
SPECIFICATION
NOTE:•Test conditions are based on ISO 5151 (Refrigerant piping length (one way) :5m).
•Refer to “3. INDOOR/OUTDOOR CORRESPONDENCE TABLE” for the combination.
w Reference value
1 Measured under rated operating frequency.2 Electrical data is for only outdoor unit.3 These specifications are when all indoor units are operating.
TEST CONDITIONS COOLING INDOOR DB27.0°C WB19.0°C
OUTDOOR DB35.0°C WB24.0°C
HEATING INDOOR DB20.0°C
OUTDOOR DB 7.0°C WB 6.0°C
21
Outdoor model
Indoor units number Piping total length Connecting pipe length Height difference (Indoor ~ Outdoor) Height difference (Indoor ~ Indoor) Function Capacity [Rated (Min.~Max.) Hz]1 Dehumidification Outdoor air flow Power outlet Running current 1 Power input Auxiliary heater Crankcase heater Power factor 1 Starting current 1 Compressor motor current Fan motor current
Model Output Winding resistance (at 20:) Model Winding resistance (at 20:) Dimensions WOHOD Weight Sound level (High/Low )
3
Fan speed (High/Low )
3 Fan speed regulator ✽3 Refrigerant filling capacity (R410A) Refrigeration oil (Model) Thermistor RT61 Thermistor RT62 Thermistor RT63 Thermistor RT68 Thermistor RT6A Thermistor RT6B Thermistor RT6C Thermistor RT6D Thermistor RT65
m m m m
kW
R/h
K /h
A A
W
A(kW)
W %
A A A
W
"
  
"
mm
kg
dB
rpm
kg
cc k" k" k" k" k" k" k" k" k"
Compressor
2 Electrical
data
Fan
motor
Special
remarks
Capacity System
Coefficient of performance (C.O.P)
Outdoor unit power supply
MXZ-A26WV -
E1
Single phase
230V,50Hz
2 to 3 Max. 50 Max. 25
10 10
25
— —
99.0
9.44
0.2
TNB220FMCH (ROTARY)
2,000
U-V 1.41
V-W 1.41 W-U 1.41
PM8H60-UA
BLK-WHT 15.2
WHT-RED 15.2 RED-BLK 15.2
900o900o320 (+35)
69
2
3.5
870 (NEO22)
13.4 (at 100:)
10.0 (at 25:)
10.0 (at 25:)
10.0 (at 25:)
10.0 (at 25:)
10.0 (at 25:)
10.0 (at 25:)
10.0 (at 25:)
17.0 (at 50:)
Cooling
7.2 (2.9~8.5) —
2,530
9.18
2,090 (720~2,560)
8.98
3.44
46/44
550/490
Heating
9.0 (2.6~11.0) —
2,630
9.44
2,150 (530~3,050)
9.24
4.19
48/46
560/490
w w w w w
w w w w w
MXZ-A32WV -
E1
Single phase
230V,50Hz
2 to 4 Max. 70 Max. 25
10 10
25
— —
99.0
9.62
0.2
TNB220FMCH (ROTARY)
2,100
U-V 1.41
V-W 1.41 W-U 1.41
PM8H60-UA
BLK-WHT 15.2
WHT-RED 15.2 RED-BLK 15.2
900o900o320 (+35)
70
2
3.5
870 (NEO22)
13.4 (at 100:)
10.0 (at 25:)
10.0 (at 25:)
10.0 (at 25:)
10.0 (at 25:)
10.0 (at 25:)
10.0 (at 25:)
10.0 (at 25:)
17.0 (at 50:)
Cooling
8.0 (3.7~9.2) —
2,530
9.62
2,190 (810~2,580)
9.42
3.65
46/44
550/490
Heating
9.4 (3.4~11.6) —
2,630
8.48
1,930 (590~3,230)
8.28
4.87
48/46
560/490
NOTE:•Test conditions are based on ISO 5151 (Refrigerant piping length (one way) :5m).
•Refer to “3. INDOOR/OUTDOOR CORRESPONDENCE TABLE” for the combination.
w Reference value
1 Measured under rated operating frequency.2 Electrical data is for only outdoor unit.3 These specifications are when all indoor units are operating.
TEST CONDITIONS COOLING INDOOR DB27.0°C WB19.0°C
HEATING INDOOR DB20.0°C
OUTDOOR DB35.0°C WB24.0°C OUTDOOR DB 7.0°C WB 6.0°C
22
6
90
80
70
60
50
40
30
20
10
63 125 250 500 1000 2000 4000 8000
APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
OCTAVE BAND SOUND PRESSURE LEVEL, 0dB = 0.0002 MICRO BAR
BAND CENTER FREQUENCIES, Hz
Test conditions.
Cooling :DB 35: WB 24: Heating :DB 7: WB 6:
CoolingHigh
FUNCTION
FAN SPEED
HeatingHigh
49
SPL(dB(A))50LINE
MXZ-A18WV -
E1
MXZ-A18WV -
E2
90
80
70
60
50
40
30
20
10
63 125 250 500 1000 2000 4000 8000
APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
OCTAVE BAND SOUND PRESSURE LEVEL, 0dB = 0.0002 MICRO BAR
BAND CENTER FREQUENCIES, Hz
Test conditions.
Cooling :DB 35: WB 24: Heating :DB 7: WB 6:
CoolingHigh
FUNCTION
FAN SPEED
HeatingHigh
46
SPL(dB(A))48LINE
MXZ-A26WV -
E1
MXZ-A32WV -
E1
90
80
70
60
50
40
30
20
10
63 125 250 500 1000 2000 4000 8000
APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
OCTAVE BAND SOUND PRESSURE LEVEL, 0dB = 0.0002 MICRO BAR
BAND CENTER FREQUENCIES, Hz
Test conditions.
Cooling :DB 35: WB 24: Heating :DB 7: WB 6:
CoolingHigh
FUNCTION
FAN SPEED
HeatingHigh
48
SPL(dB(A))49LINE
MXZ-A14WV -
E1
MXZ-A14WV -
E2
OUTDOOR UNIT
MICROPHONE
1m
NOISE CRITERIA CURVES
23
7
(
)
OUTLINES AND DIMENSIONS
OUTDOOR UNIT
MXZ-A14WV ­MXZ-A14WV ­MXZ-A18WV ­MXZ-A18WV -
273
Drainage 3 holes
([33)
Air in
65
50
E1
E2
E1
E2
Open as a rule More than100mm if the front and both sides are open
*
More than 100mm 200mm or more if there are obstacles to both sides
More than 350mm
587
Air in
Air out
121
500
840
REQUIRED SPACE
More than
34
330
360
40
69
100mm
Open as a rule More than 200mm if the back, both sides and top are open
Note:
*
The dimensions given along the arrrows above are required to guarantee the air conditioner's performance. Install the unit in as wide a place as possible for later service or repairs.
Service panel
Unit: mm
320
640
195
Liquid refrigerant valve (flared [6.35)
B UNIT
}
A UNIT
}
90 65 65 65
Gas refrigerant valve
flared [9.52
24
Loading...