NOTE: Test conditions are based on ISO 5151.
Cooling: Indoor Dry-bulb temperature 27°C Wet-bulb temperature 19°C
Outdoor Dry-bulb temperature 35°C Wet-bulb temperature 24°C
Heating: Indoor Dry-bulb temperature 20°C Wet-bulb temperature -°C
Outdoor Dry-bulb temperature 7°C Wet-bulb temperature 6°C
Indoor-Outdoor piping length: 5 m
SPECIFICATION
Single phase
230 V, 50 Hz
Breaker capacityA1515
Running current (Total)
Power input (Total)W1,8101,7801,610
data
Power factor (Total)%9694
Starting current (Total)
ModelRN196VHSHTRN196VHSHT
OutputW1,3001,300
Compressor
Compressor motor current
ModelRA6V33-KARA6V33-KB
Fan motor currentA0.330.33
motor
Dehumidifi cation/h2.52.5
Air fl ow/h1,9021,902
Sound leveldB5252
Fan speedrpm855855
Fan speed regulator11
remarks
Refrigerant fi lling
capacity (R410A)
Refrigeration oil (Model)
A8.208.237.53
A3737
2.762.813.23
A7.577.606.90
550 285800 550 285
kg1.351.45
cc520 (NEO 22)520 (NEO 22)
MUH-GE50VB
ACCESSORIES
<Outdoor unit: MUH type>
Drain socket
Single phase
230 V, 50 Hz
-
1
3
4
MU-GE50VB
NOISE CRITERIA CURVES
COOL
SPL(dB(A))LINE
52
FUNCTION
Test conditions,
Cooling :Dry-bulb temperature35°C Wet-bulb temperature24°C
90
MUH-GE50VB
FUNCTION
COOLING
HEATING
SPL(dB
Test conditions,
Cooling :Dry-bulb temperature35°C Wet-bulb temperature24°C
Heating :Dry-bulb temperature 7°C Wet-bulb temperature 6°C
90
(A))LINE
52
80
70
60
50
40
30
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 MICRO BAR
20
10
631252505001000200040008000
BAND CENTER FREQUENCIES, Hz
80
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
NC-10NC-10
70
60
50
40
30
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 MICRO BAR
Gas refrigerant pipe joint
Refrigerant pipe (flared) ø12.7
200mm or more
Open two sides of left,
right, or rear side.
43°
Basically open 100mm or more
without any obstruction in front
and on both sides of the unit.
100mm or more
350mm or more
5
6
MU-GE50VB
WIRING DIAGRAM
MUH-GE50VB
6
7
REFRIGERANT SYSTEM DIAGRAM
MU-GE50VB
OUTDOOR UNIT
Refrigerant pipe 12.7
(with heat insulator)
Flared connection
Flared connection
Stop valve
(with service port)
Stop valve
Unit :mm
Muffler
Outdoor
heat
exchanger
Compressor
Strainer
#100
Refrigerant pipe 6.35
(with heat insulator)
MUH-GE50VB
OUTDOOR UNIT
Refrigerant pipe ø12.7
(with heat insulator)
Flared connection
Flared connection
Stop valve
(with service
port)
Strainer
#100
Capillary tube
3.0 x 1.6 x 450
4-way valve
Muffler
Compressor
Check valve
Outdoor
heat
exchanger
Capillary tube
ø3.0 × ø1.8 × 600
(2 pcs)
Capillary tube
ø3.0 × ø1.6 × 500
Refrigerant pipe ø6.35
(with heat insulator)
Stop valve
Capillary tube
ø3.0 × ø1.6 × 300
7
R.V. coil
heating ON
cooling OFF
Defrost
thermistor
RT61
Refrigerant flow in cooling
Refrigerant flow in heating
MAX. REFRIGERANT PIPING LENGTH
Model
MU-GE50VB
MUH-GE50VB
Refrigerant piping: m
Max. lengthAMax. height
B
25
10
Piping size O.D: mm
Gas
12.7
MAX. HEIGHT DIFFERENCE
Indoor
unit
Refrigerant Piping
Max. height
B
Max. length
A
ADDITIONAL REFRIGERANT CHARGE (R410A: g)
Model
MU-GE50VB
MUH-GE50VB
Outdoor unit precharged
1350
1450
7 m
0
Length of connecting pipe: m
Liquid
6.35
Outdoor unit
Refrigerant piping length (one way)
10 m
60
Indoor unit
Gas 0.43
Liquid 0.5
15 m
160
Calculation : Xg = 20 g/m × (A-7)m
20 m
260
Outdoor unit
Gas 0
Liquid 0
25 m
360
8
PERFORMANCE CURVES
MU-GE50VB MUH-GE50VB
The standard specifications apply only to the operation of the air conditioner under normal conditions, since operating conditions vary according to the areas where these units are installed. The following information has been provided to clarify the
operating characteristics of the air conditioner under the conditions indicated by the performance curve.
(1) GUARANTEED VOLTAGE
198~264 V
(2) AIR FLOW
Air flow should be set at MAX.
(3) MAIN READINGS
(1) Indoor intake air wet-bulb temperature: °CWB
(2) Indoor outlet air wet-bulb temperature: °CWB
(3) Outdoor intake air dry-bulb temperature: °CDB
(4) Total input: W
(5) Indoor intake air dry-bulb temperature: °CDB
(6) Outdoor intake air wet-bulb temperature: °CWB
(7) Total input: W
Indoor air wet/dry-bulb temperature difference on the left side of the following chart shows the difference between the
indoor intake air wet/dry-bulb temperature and the indoor outlet air wet/dry-bulb temperature for your reference at service.
8
Cooling
}
Heating (MUH-GE50VB)
}
How to measure the indoor air wet-bulb/dry-bulb temperature difference
1. Attach at least 2 sets of wet and dry-bulb thermometers to the indoor air intake as shown in the figure, and at least 2 sets
of wet and dry-bulb thermometers to the indoor air outlet. The thermometers must be attached to the position where air
speed is high.
2. Attach at least 2 sets of wet and dry-bulb thermometers to the outdoor air intake.
Cover the thermometers to prevent direct rays of the sun.
3. Check that the air filter is cleaned.
4. Open windows and doors of room.
5. Press the EMERGENCY OPERATION switch once (twice) to start the EMERGENCY COOL
[HEAT (MUH-GE50VB)]
6. When system stabilizes after more than 15 minutes, measure temperature and take an average temperature.
7. 10 minutes later, measure temperature again and check that the temperature does not change.
MODE.
INDOOR UNIT
Wet and dry-bulb
thermometers
8-1. CAPACITY AND THE INPUT CURVES
11.6
10.6
9.6
8.6
7.7
difference(degree)
6.9
Indoor air Wet-bulb temperature
Indoor intake air Wet-bulb temperature
OUTDOOR UNIT
Wet and dry-bulb
thermometers
ulb temperature
t-b
Indoor intake air
We
MUH-GE50VB
MU-GE50VB
26.6
24.5
22.5
20.4
18.4
16.3
difference(degree)
14.3
Indoor air Dry-bulb temperature
12.3
MUH-GE50VB
Outdoor intake air Dry-bulb temperature
lb temperature
oor intake air Dry-bu
Ind
Outdoor intake air Wet-bulb temperature
NOTE: The above curves are for the heating operation without any frost.
Outdoor intake air Dry-bulb temperature
intake air Dry-bulb temperature
oor
Ind
Outdoor intake air Wet-bulb temperature
9