MITSUBISHI MF-10KDS-T12-06x, MF-10KDS-T12-07x, MF-10KDS-R13-06x, MF-10KDS-R13-07x User Manual

MF-10KDS-T12-06x/07x
MF-10KDS-R13-06x/07x
DESCRIPTION
Th is prod uct is designed to provide high optic al performance for SDH STM-64/SONE T OC-192. Trans mitte r us es co oled laser in a but t erf ly pac kag e module wit h driv ered by spec ific integrated circuit. Receiver us es PD preamp -modul e (butterf ly package module) and integrat ed circuit s for reshaping, retim ing and regenerating optical signal.
FEATURES
Full SONET/SDH line up
K connector interface
-5.2V,+5V power supply target, -2.2V(TX only) Case Temp. Range: 10 to 65°C
Clock recovery and digital alarm function.
APPLICATION
Short haul and long haul telecommunication systems for SDH STM64 / SONET OC-192.
MITSUBISHI (OPTICAL DEVICES)
SONET/SDH TRANSMITTER & RECIEVER
ABSOLUTE MAXIMUM RATINGS
Stress below listed absolute maximum rating may cause permanent damage to the transmitter and receiver. This is a stress only and func tional operation of the transceiver at these or any other conditions in excess of those given in the operational sections of this data sheet is not implied. Exposure to Absolute Maximum Rating for extended periods may affect transmitter and receiver reliability.
Tc=25°C
Parameters Symbol Ratings Unit
Vcc +5.3 V
Vee -6.0 VSupply voltage
Vtt -2.4 V
Storage temperature Tstg -40 to 85
Operating case temperature Tc 10 to 65
Relative humidity(non condensation) - 10 to 80 %
Fiber bend radius rF 32 mm
C
°
C
°
MITSUBISHI (OPTICAL DEVICES)
MF-10KDS-T12-06x/07x
MF-10KDS-R13-06x/07x
SONET/SDH TRANSMITTER & RECIEVER
ELECTRICAL CHARACTERISTICS
All parameters are specified over the operating case temperature. Measurement conditions are at 9953.28Mb/s+/-20ppm, NRZ PN2
Vcc=+5.0V+/-5%, Vee=-5.2V+/-5%, Vtt=-2.2V+/-0.1V,Tc=10 to 65 °C, Using a PRBS 2 50%Mark ratio, unless otherwise noted.
Transmitter
Parameters Condition Symbol Min. Typ. Max. Unit
Supply voltage
Supply current
23
-1 and 50%duty cycle data signal.
Vee -5.46 -5.2 -4.94 V Vcc 4.75 5.0 5.25 V
Vtt -2.3 -2.2 -2.1 V
Iee - - 1.5 A
Icc - - 1.0 A
23
-1 pattern with a
Itt - ­Data / Clock input voltage (DC:50ohm) note 1 - SCFL ­Data / Clock relationship note 5 Td -20 - +20 psec
Function note 2,3 -
Sh utdow n, Laser Degr adati on, Power out of rang e Alarm, Laser Over Tem pera ture Alarm
1. 2
Receiver
Parameters Condition Symbol Min. Typ. Max. Unit
Vee -5.46 -5.2 -4.94 V
Supply voltage
Vcc 4.75 5.0 5.25 V
Iee - - 1.5 A
Supply current
Icc - - 1.5 A
Data output voltage (DC:50ohm) note 4 - SCFL -
Clock output voltage (AC:50ohm) note 4 0.5 - 1.5 Vpp
Data / Clock relationship note 5 Td -25 - +25 psec
A
-
Jitter - TBD -
Function note 6 - Loss of Signal Alarm -
MITSUBISHI (OPTICAL DEVICES)
MF-10KDS-T12-06x/07x
MF-10KDS-R13-06x/07x
SONET/SDH TRANSMITTER & RECIEVER
OPTICAL CHARACTERISTICS
Parameter Symbol Specification Unit
ITU code - S-64.2 S-64.3 -
- - Min. Max. Min. Max. ­Dispersion - -800 +800 -130 +130 ps/nm Optical path penalty Pp - 2 - 1 dB
Transmitter
Wavelength - 1530 1565 1530 1565 ­Optical output power Pout -3 +3 -2 +3 dBm Spectral width(-20dB) - - 0.5 - 0.5 nm SMSR - 30 - 30 - dB Extinction Ratio Ex 8.2 - 8.2 - dB
Receiver
Sensitivity - - -14 - -13 dBm Overload - -3 - -3 - dBm
note : Bit Rate 9953.28Mb/s,PRBS223-1, BER<=10
-12
ORDERING INFORMATION
Transmitter
Part number ITU-code Optical connector type MF-10KDS-T12-060 S-64.2 FC MF-10KDS-T12-061 S-64.2 SC MF-10KDS-T12-070 S-64.3 FC MF-10KDS-T12-071 S-64.3 SC
Receiver
Part number ITU-code Optical connector type MF-10KDS-R13-060 S-64.2 FC MF-10KDS-R13-061 S-64.2 SC MF-10KDS-R13-070 S-64.3 FC MF-10KDS-R13-071 S-64.3 SC
MITSUBISHI (OPTICAL DEVICES)
MF-10KDS-T12-06x/07x
MF-10KDS-R13-06x/07x
SONET/SDH TRANSMITTER & RECIEVER
TRANSMITTER PIN ALLOCATION
No. Symbol Description No. Symbol Description
1 -2.2V Supply voltage for cooler 2 -2.2V Supply voltage for cooler 3 GND Ground 4 NUC No user connection 5 LDMON Laser Bias Monitor 6 PDMON Laser Backface Monitor 7 DEG Laser Degradation Alarm 8 ORA Power Out of Range Alarm 9 LOT Laser Over Temperature Alarm 10 SDC Shut Down Command 11 GND Ground 12 GND Ground 13 GND Ground 14 GND Ground 15 +5V Supply voltage 16 +5V Supply voltage 17 +5V Supply voltage 18 +5V Supply voltage 19 GND Ground 20 GND Ground 21 GND Ground 22 GND Ground 23 -5.2V Supply voltage 24 -5.2V Supply voltage 25 -5.2V Supply voltage 26 -5.2V Supply voltage 27 GND Ground 28 GND Ground 29 GND Ground 30 GND Ground
RECEIVER PIN ALLOCATION
No. Symbol Description No. Symbol Description 1 GND Ground 2 GND Ground 3 GND Ground 4 LOS Loss of signal alarm 5 NUC No user connection 6 NUC No user connection 7 NUC No user connection 8 NUC No user connection 9 NUC No user connection 10 NUC No user connection 11 GND Ground 12 GND Ground 13 GND Ground 14 GND Ground 15 +5V Supply voltage 16 +5V Supply voltage 17 +5V Supply voltage 18 +5V Supply voltage 19 GND Ground 20 GND Ground 21 GND Ground 22 GND Ground 23 -5.2V Supply voltage 24 -5.2V Supply voltage 25 -5.2V Supply voltage 26 -5.2V Supply voltage 27 GND Ground 28 GND Ground 29 GND Ground 30 GND Ground
GENERAL OUTLINE DRAWING
Transmitter
MITSUBISHI (OPTICAL DEVICES)
MF-10KDS-T12-06x/07x
MF-10KDS-R13-06x/07x
SONET/SDH TRANSMITTER & RECIEVER
NOTE: TOLERANCES UNLESS NOTED +/-0.5
DIMENSIONS ARE IN MILLIMETERS
Receiver
BLOCK DIAGRAM
EA-LD Module
MF-10KDS-T12-06x/07x
MF-10KDS-R13-06x/07x
SONET/SDH TRANSMITTER & RECIEVER
VCC VCC
LD
PD
MITSUBISHI (OPTICAL DEVICES)
DATAin DATAin CLOCK CLOCK
SDC
integrated device
DRIVER IC
PD-Preamp Module
Driver IC
Thermistor
A.P.C
Transmitter
A.T.C
OPT. OUT
Cooler
LOT
ORA
DEG
OPT. IN
PD
Preamp
Clock recovery IC
PLL
Alarm
Receiver
DATAout
DATAout CLKout
CLKout
LOS
NOTE
NOTE1: Input interface
MITSUBISHI (OPTICAL DEVICES)
MF-10KDS-T12-06x/07x
MF-10KDS-R13-06x/07x
SONET/SDH TRANSMITTER & RECIEVER
Transmitter
Data
NOTE2: Shut down interface
H
L
TTL
Data
0V
-0.9V
DC Coupled Interface
50ohm
OFF ON
Transmitter
comparator
NOTE3: Laser Degradation Alarm / Power out of range Alarm / LD temperature out of range Alarm
Laser Degradation Alarm (DEG ) set s when the bias current is at least 70% higher than
the maximum initial value allowed .
Alarm active: TTL LOW
Power out of range Alarm (OR A), sets when the output opt ical output pow er is 3dB(t yp.) less than the initial optical output level.
Alarm active: TTL LOW
Lase r Over Tem per ature A larm (L OT), set s when t he t empe rat ure of LD incr ease o r decrease more than 15deg.C from the initial temperature.
Alarm active: TTL LOW
NOTE4: LVPECL Output interface
Receiver
MITSUBISHI (OPTICAL DEVICES)
MF-10KDS-T12-06x/07x
MF-10KDS-R13-06x/07x
SONET/SDH TRANSMITTER & RECIEVER
100ohm
Data / Data Clock / Clock
note:DC Couple for Data AC Couple for Clock
NOTE5: Data and Clock relationship
Data
Clock
Td
Tx
NOTE6: LOS of signal interface
Td < 20psec.
50ohm
Data
Clock
50ohm
Td
Td < 25psec.
Rx
Receiver
Optical signal OFF ON Signal detect
Signal detect
activated deactivated
TTL
H L
Loading...