Mitsubishi LGH-40ES-E TECHNICAL MANUAL

A ventilation system that saves energy even while keeping your room comfortable. A sleek, compact design that fits well with any decor. Easy maintenance is a plus.
Product Features
POINT
The simultaneous intake/exhaust of air together with the Lossnay core recovers temperature and humidity from the room while ventilating, making this unit both economical and environmentally friendly.
POINT
A mere 255 mm from front to back, this thin design takes up a minimum of space even when suspended from the ceiling of an existing building.
POINT
In addition to this lightweight and compact design, connection to the outdoor unit requires just a 200 mm diameter round duct. Neither is there any need to redo the ceiling after installation. (Does not require inspection opening.)
1
Compact design
2
Minimal installation needs
3
255
Unit (mm)
POINT
Designed to eliminate the outflow of air to the space directly beneath the unit, there is no worry of discomfort from drafts.
POINT
Air filter can be cleaned or replaced from the bottom of the unit. (Does not require inspection opening.) The Lossnay core should be cleaned with a vacuum cleaner at least once every 2 years. The airfilter on the intake side of the Lossnay core with vacuum cleaner or water at least once every year.
A refined design
4
Easy maintenance
5
Screw
Te rminal block cover
PG connection
Cord clip
Dimensions
255
15
(*1)
290
30
(*1)
SA (Supply air )
Ceiling suspension fixture (4 pcs.)
693
495
φ200
127.5
RA (Return air)
Control Switch (PZ-03SLP-E)
20.4
116
12.2
6.5
Characteristic Curves
Exchange
80
efficiency
(%)
70
60
50
40
300
Temperature recovery efficiency
Enthalpy recovery efficiency (Heating)
Enthalpy recovery efficiency (Cooling)
98
CoolingHeating
High
Low
40
48
Air volume
Noise
(dB(A))
41-43
32-34
(m3/h)
Weight
(kg)
25
Power supply terminal block * Power supply cord
take-in opening at the top face
OA
(Outside air intake)
600 845
900
EA
(Exhaust air outlet)
68
*1: Dimension of opening to take in power supply cords.
Specifications
Model
LGH-40ES-E
Voltage
(V)
1-Phase
220~240
Line frequency
(Hz)
50
Fan speed
High
Power Consumption
Low
Powe r lamp
Fan speed selector switch
(W)
132-146
82-95
120
Te r minal board
Power switch Switch box
Air volume
(m3/h)
400
250
(L/s)
111
69
117
Unit (mm)
Temperature
recovery
efficiency (%)
60
66
200
(Pa)
100
External static pressure
0 100 200 300 400 500
Enthalpy recovery
efficiency (%)
45
54
*The value of noise has been measured at an anechoic chamber and it could vary depending on the structure or materials of room or members used to mount the main unit.
50Hz
Electrical Installation
Wiring Diagrams
Breaker
L
Power source
N
220-240V ~50Hz
ON/OFF
HIGH/LOW
CONTROL BOX OF LOSSNAY UNIT
Terminal BIock
Red
1
High
White
2
N
Brown
3
Low
Relay X
Red
3
Blue
5
White
1
C
Green/Yellow
4
Gray
6
Yellow
2
8
X
Green/Yellow Green/Yellow
C
7
Brown
Black Pink
Black Pink
LOSSNAY UNIT
Red
Blue White
M1
Black
(Exhaust)
Pink
Green/Yellow
Red Blue White Black
M2
Pink
(Supply)
Green/Yellow
*Attention
1.
Connect the wires indicated by the bold lines.
2. Be sure to connect the grounding wire.
3. Breakers and control switches should be provided by the customer.
Off-the-shelf food may be used where there is no risk of rain water, such as under the roof, or others.
Ceiling suspension fixture position
167
RA (Return air)
Control switch PZ-03SLP-E
Weather cover PZ-20CVU
2-E
OA
(Outside air intake)
EA
(Exhaust air outlet)
Flexible duct
More than 150
Between wall surface and back of main unit.
When a window is changed into an aluminum
board and duct piping is carried out.
Ceiling suspension fixture position
Spring hook
*Attention
• Provide heat insulation to prevent moisture condensation along the two outside ducts (fresh-air intake and exhaust-air outlet).
• Do not use vent caps or round hoods in places
Weather cover PZ-20CVU2-E
Cord bushing Power supply terminal block
Sample Installations
495
(
Ceiling suspension
Maintenance
space
fixture pitch)
More than 400More than 400
Cercuit
maintenance
space
More than 68
EA
(Exhaust air outlet)
OA
(Outside air intake)
Anchor bolt, nut
(prepared by the customer)
Ceiling
845
600
10
SA
(Supply air)
(Ceiling suspension fixture pitch)
Spring hook
directly exposed to rain.
*Attention Installation conditions:
• Ambient conditions: Temperature -10°C to +40°C, relative humidity less than 80%. When condensation is expected to form, heat up the outside air using a duct heater, etc.
• Outside air intake conditions: Temperature -10°C to +40°C, relative humidity less than 80%.