JY997D35001G
48(1.88")
4)
36(1.41")
3)
1)
2)
22(0.86")
Serial Multi-Drop
Connection Unit
*2
Signal name
SDA
SDB
RDA
RDB
SG
Connection
Conversion
Adapter
(GOT)
*1
Signal name
SDA
SDB
RDA
RDB
SG
Signal name
SDA
SDB
RDA
RDB
SG
*3 *3
Connection
Conversion
Adapter
(GOT)
*2
Signal name
RDA
RDB
SDA
SDB
SG
Signal name
SDA
SDB
RDA
RDB
SG
Signal name
SDA
SDB
RDA
RDB
SG
*3 *3
Serial Multi-Drop
Connection Unit
*2
Connection
Conversion
Adapter
(GOT)
*1
Connection
Conversion
Adapter
(GOT)
*2
Side
JAPANESE
A
Side
ENGLISH
B
GT10-9PT5S
Connection Conversion Adapter
User's Manual
Manual Number JY997D35001G
Date April 2018
This manual describes the part names, external dimensions, and specifications of
the product. Before use, read this manual and manuals of relevant products fully
to acquire proficiency in handling and operating the product. Make sure to learn all
the product information, safety information, and precautions.
And, store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
Registration
The company name and the product name to be described in this manual are the
registered trademarks or trademarks of each company
Effective April 2018
Specifications are subject to change without notice.
Safety Precaution
Before using this product, please read this manual and the relevant manuals
introduced in this manual carefully and pay full attention to safety to handle the
product correctly.
The precautions given in this manual are concerned with this product.
In this manual, the safety precautions are ranked as and .
Depending on circumstances, procedures indicated by may also be
linked to serious results.
In any case, it is important to follow the directions for usage.
MOUNTING
PRECAUTIONS
Use the
connection conversion adapter
general specifications described in this manual. Not doing so can cause an
electric shock, fire, malfunction or product damage or deterioration.
OPERATION
PRECAUTIONS
Power OFF the GOT, and then connect securely the
to the specified connector in the GOT.
adapter
Poor connection may cause malfunction.
Remove static electricity charged in the human body before handling the
connection conversion adapter
Static electricity may damage the stored data and elements.
DISPOSAL PRECAUTIONS
When disposing of the product, handle it as industrial waste.
2009 MITSUBISHI ELECTRIC CORPORATION
(Read these precautions before using.)
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
in the environment that satisfies the
connection conversion
.
Side
B
Related Manuals
The following manuals are relevant to this product. When these loose manuals are
required please consult with our local distributor.
Manual name
GOT2000 Series
User's Manual
(Hardware)
GOT2000 Series
Handy GOT
Connection
Manual For GT
Works3 Version1
GT10
User's Manual
GT11
User's Manual
GOT1000 Series
Connection
Manual
1/3, 2/3, 3/3
GOT1000 Series
Connection
Manual
(Mitsubishi
Products) for GT
Works3
Referenced Standard: GB/T15969.2 (Requirement of Chinese standardized law)
1. Overview
The connection conversion adapter GT10-9PT5S (hereinafter referred to as
"connection conversion adapter") is designed to be attached to the GOT for facilitate
crossover wiring in GOT multi-drop connection.
The following GOT models support the connection conversion adapter connection.
Manual Number
(Model Code)
SH-081194ENG
(1D7MJ5)
SH-081867ENG
(1D7MS9)
JY997D24701
(09R819)
JY997D17501
(09R815)
SH-080532ENG
(1D7M26)
SH-080868ENG
(1D7MC2)
Contents
Describes the GOT hardware relevant content
such as part names, external dimensions,
mounting, power supply wiring, specifications,
and introduction to option devices
Describes system configurations of the
connection method applicable to GOT2000
Series Handy GOT and cable creation method
Describes the GT10 hardware-relevant
content such as part names, external
dimensions, mounting, wiring, specifications,
and introduction to option devices. (sold
separately)
Describes the GT11 hardware-relevant
content such as part names, external
dimensions, mounting, wiring, specifications,
and introduction to option devices. (sold
separately)
Describes system configurations of the
connection method applicable to GOT1000
series and cable creation method.
(sold separately)
Describes system configurations of the
connection method applicable to GOT1000
series and cable creation method.
(sold separately)
GOT Hardware version
GOT 2000
GOT 1000
For the confirming method of hardware version, refer to user’s manual.
GT2505-VTBD, GT2105-QTBDS,
GT2105-QMBDS
GT1455-QTBDE, GT1450-QLBDE,
GT1455-QTBD, GT1450-QLBD
GT1155-QTBD Version C or later
GT1155-QSBD, GT1150-QLBD Version F or later
GT1055-QSBD, GT1050-QBBD Version C or later
GT1045-QSBD, GT1040-QBBD Version A or later
-
Version A or later
2. Part Names and External Dimensions
Unit: mm(inch)
No. Name Contents
Multi-drop connection
1)
terminal block
2) GOT connector
3) Fixing screw hole M3 tapping screws (accessory)
1pair/2pair signal selection
4)
switch
2 step type terminal block 5-pin
D-Sub 9-pin male
1Pair/2Pair
3. Specifications
3.1 General Specifications
Item Specifications
Operating ambient
temperature
Storage ambient
temperature
Operating/Storage
ambient humidity
Operating atmosphere
0 to 55C
-20 to 60C
10 to 90% RH, non-condensing
Must be free of lamp black, corrosive gas, flammable
gas, or excessive amount of electro conductive dust
particles and must not be exposed to direct sunlight
(during operation and storage).
4. Pin assignment
Tightening torque: 0.22 to 0.25N•m
Pin No. Signal name Pin No. Signal name
1SG 6SG
2SDB 7SDB
3SDA 8SDA
4RDB 9RDB
5 RDA 10 RDA
5. Installation
1) Connect the connection conversion
adapter to the RS-422/485
interface on the GOT.
2) Fix the connection conversion
adapter to the GOT using the
provided M3 tapping screws.
Tightening torque : 0.3 to 0.6 Nm
6. Wiring
This paragraph describes connection between the connection conversion adapter
and the serial multi-drop connection unit.
For details of GOT multi-drop connection, refer to the GOT1000 Series Connection
Manual.
6.1 1 pair wiring
Set the 1pair/2pair signal selection switch to "1Pair" when using the connection
conversion adapter.
*1 Set the terminating resistor selector to "OPEN".
*2 Set the terminating resistor selector to "110".
*3 Make sure to ground a cable shield line by applying Class D Grounding (100
or less).
6.2 2 pair wiring
Set the 1pair/2pair signal selection switch to "2Pair" when using the connection
conversion adapter.
*1 Set the terminating resistor selector to "OPEN".
*2 Set the terminating resistor selector to "330".
*3 Make sure to ground a cable shield line by applying Class D Grounding (100
or less).
This manual confers no industrial property rights or any rights of any other
kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation
cannot be held responsible for any problems involving industrial property rights
which may occur as a result of using the contents noted in this manual.
Warranty
Mitsubishi will not be held liable for damage caused by factors found not to be
the cause of Mitsubishi; opportunity loss or lost profits caused by faults in the
Mitsubishi products; damage, secondary damage, accident compensation
caused by special factors unpredictable by Mitsubishi; damages to products
other than Mitsubishi products; and to other duties.
For safe use
This product has been manufactured as a general-purpose part for general
industries, and has not been designed or manufactured to be incorporated in
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric
power, aerospace, medicine or passenger movement vehicles, consult with
Mitsubishi Electric.
This product has been manufactured under strict quality control. However
when installing the product where major accidents or losses could occur if the
product fails, install appropriate backup or failsafe functions in the system.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN