This manual describes the specifications of the product. Before use,
read this manual and manuals of relevant products fully to acquire
proficiency in handling and operating the product. Make sure to learn
all the product information, safety information, and precautions. And,
store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
Registration
The company name and the product name to be described in this
manual are the Registered trademarks or trademarks of each
company.
Safety Precaution (Read these precautions before use.) This manual
classifies the safety precautions into two categories: DANGER and
CAUTION.
DANGERIndicates that incorrect handling may cause
hazardous conditions, resulting in death or severe injury.
CAUTION Indicates that incorrect handling may cause
hazardous conditions, resulting in medium or slight personal injury
or physical damage.
Depending on the circumstances, procedures indicated by CAUTION
may also cause severe injury. It is important to follow all precautions for
personal safety.
DANGER DESIGN PRECAUTIONS
• Some failures of the GOT or cable may keep the outputs on or off.
An external monitoring circuit should be provided to check for output
signals which may lead to a serious accident. Not doing so can
cause an accident due to false output or malfunction.
• If a communication fault (including cable disconnection) occurs
during monitoring on the GOT, communication between the GOT
and PLC CPU is suspended and the GOT becomes inoperative. A
system where the GOT is used should be configured to perform any
significant operation to the system by using the switches of a device
other than the GOT on the assumption that a GOT communication
fault will occur. Not doing so can cause an accident due to false
output or malfunction.
• Do not use the GOT as the warning device that may cause a serious
accident. An independent and redundant hardware or mechanical
interlock is required to configure the device that displays and outputs
serious warning. Failure to observe this instruction may result in an
accident due to incorrect output or malfunction.
• Incorrect operation of the touch switch(s) may lead to a serious
accident if the GOT backlight is gone out. When the GOT backlight
goes out, causes the monitor screen to appear blank, while the input
of the touch switch(s) remains active. This may confuse an operator
in thinking that the GOT is in “screensaver” mode, who then tries
to release the GOT from this mode by touching the display section,
which may cause a touch switch to operate.
CAUTION DESIGN PRECAUTIONS
• Do not bundle the control and communication cables with maincircuit, power or other wiring. Run the above cables separately from
such wiring and keep them a minimum of 100mm (3.94 in.) apart.
Not doing so noise can cause a malfunction.
• Do not press the GOT display section with a pointed material as
a pen or driver. Doing so can result in a damage or failure of the
display section.
• Before connecting to GOT, turn ON the controller to enable the
communication. When the communication of controller is not
available, a communication error may occur in GOT.
DANGER MOUNTING PRECAUTIONS
• Be sure to shut off all phases of the external power supply used by
the system before mounting or removing the GOT to/from the panel.
Not doing so can cause the unit to fail or malfunction.
• When installing the battery wear an earth band etc. to avoid the
static electricity. The static electricity can cause the unit to fail or
malfunction.
CAUTION MOUNTING PRECAUTIONS
• Use the GOT in the environment that satisfies the general
specifications described in this manual. Not doing so can cause an
electric shock, fire, malfunction or product damage or deterioration.
• When mounting the GOT to the control panel, tighten the mounting
screws in the specified torque range. Undertightening can cause
the GOT to drop, short circuit or malfunction, and deteriorate the
waterproof effect and oilproof effect.
• Overtightening can cause a drop, short circuit or malfunction
due to the damage of the screws or the GOT, and deteriorate the
waterproof effect and oilproof effect due to distortion of the protective
cover for oil, GOT or panel.
• When using the GOT in the environment of oil or chemicals, use
the protective cover for oil. Failure to do so may cause failure or
malfunction due to the oil or chemical entering into the GOT.
DANGER WIRING PRECAUTIONS
• Be sure to shut off all phases of the external power supply used by
the system before wiring. Failure to do so may result in an electric
shock, product damage or malfunctions.
• Please make sure to ground FG terminal of the GOT power supply
section by applying 100 or less which is used exclusively for the
GOT. Not doing so may cause an electric shock or malfunction.
• Correctly wire the GOT power supply section after confirming the
rated voltage and terminal arrangement of the product. Not doing so
can cause a fire or failure.
• Tighten the terminal screws of the GOT power supply section in the
specified torque range. Undertightening can cause a short circuit or
malfunction. Overtightening can cause a short circuit or malfunction
due to the damage of the screws or the GOT.
• Exercise care to avoid foreign matter such as chips and wire
offcuts entering the GOT. Not doing so can cause a fire, failure or
malfunction.
CAUTION WIRING PRECAUTIONS
• Plug the communication cable into the connector of the connected
unit and tighten the mounting and terminal screws in the specified
torque range. Undertightening can cause a short circuit or
malfunction. Overtightening can cause a short circuit or malfunction
due to the damage of the screws or unit
DANGER TEST OPERATION PRECAUTIONS
• Before performing the test operations of the user creation monitor
screen (such as turning ON or OFF bit device, changing the word
device current value, changing the settings or current values of
3
GT105_ QUICK START MANUAL
100mm250mm
140mm
GT01-C30R4-8P
Comes equipped
GOT units
Programmablecontroller
Added by user
(9.84inch)
(3.93inch)
(5.51inch)
Ex.1F = Ferrite coreEx. NEC TOKIN - ESD-R-17S or similar
FFF
Mitsubishi Electric Automation, Inc.
the timer or counter), read through the manual carefully and make
yourself familiar with the operation method. During test operation,
never change the data of the devices which are used to perform
significant operation for the system. False output or malfunction can
cause an accident..
DANGER STARTUP/MAINTENANCE PRECAUTIONS
• When power is on, do not touch the terminals. Doing so can cause
an electric shock or malfunction.
• Connect the battery correctly. Do not discharge, disassemble, heat,
short, solder or throw the battery into the fire. Incorrect handling may
cause the battery to generate heat, burst or take fire, resulting in
injuries or fires.
• Before starting cleaning or terminal screw retightening, always switch
off the power externally in all phases. Not switching the power off in
all phases can cause a unit failure or malfunction. Undertightening
can cause a short circuit or malfunction. Overtightening can cause a
short circuit or malfunction due to the damage of the screws or unit.
CAUTION STARTUP/MAINTENANCE PRECAUTIONS
• Do not drop or apply any impact to the battery. If any impact has
been applied, discard the battery and never use it. The battery may
be damaged by the drop or impact.
• Before touching the unit, always touch grounded metal, etc. to
discharge static electricity from human body, etc. Not doing so can
cause the unit to fail malfunction.
• Replace battery with GT11-50BAT by Mitsubishi electric Co. only. Use
of another battery may present a risk of fire or explosion.
• Dispose of used battery promptly. Keep away from children. Do not
disassemble and do not dispose of in fire..
CAUTION DISPOSAL PRECAUTIONS
• When disposing of the product, handle it as industrial waste.
• When disposing of batteries, separate them from other wastes
according to the local regulations.
CAUTION TOUCH PANEL PRECAUTIONS
• For the analog-resistive film type touch panels, normally the
adjustment is not required. However, the difference between a
touched position and the object position may occur as the period of
use elapses. When any difference between a touched position and
the object position occurs, execute the touch panel calibration.
• When any difference between a touched position and the object
position occurs, other object may be activated. This may cause an
unexpected operation due to incorrect output or malfunction.
CAUTION TRANSPORTATION PRECAUTIONS
• When transporting lithium batteries, make sure to treat them based
on the transport regulations. (Refer to User’s Manual for details of
the regurated models.)
• Before transporting the GOT, turn the GOT power on and check that
the battery voltage status is normal on the Time setting & display
screen (utilities screen). In addition, confirm that the adequate
battery life remains on the rating plate. Transporting the GOT with
the low battery voltage or the battery the reached battery life may
unstabilize the backup data unstable during transportation.
• Make sure to transport the GOT main unit and/or relevant unit(s) in
the manner they will not be exposed to the impact exceeding the
impact resistance described in the general specifications of this
manual, as they are precision devices. Failure to do so may cause
the unit to fail.
• Check if the unit operates correctly after transportation.
4
1.2 CERTIFICATION
Compliance with EC directive (CE Marking)
This note does not guarantee that an entire mechanical module
produced in accordance with the contents of this note will comply with
the following standards. Compliance to EMC directive for the entire
mechanical module should be checked by the user/manufacturer. For
more details please contact the local Mitsubishi Electric sales site.
• This product is designed for use in industrial applications.
• Authorized Representative in the European Community:
Mitsubishi Electric Europe B.V.
Gothaer Str. 8, 40880 Ratingen, Germany
Requirement for Compliance with EMC directive
The following products have shown compliance through direct testing
(to the identified standards) and design analysis (forming a technical
construction file) to the European Directive for Electromagnetic
Compatibility (2004/108/EC) when used as directed by the appropriate
documentation. Type :Programmable Controller (Open Type
Equipment)
Standard Remark
EN61131-2 : 2007
Programmable controllersEquipment, requirement
and tests
EMI
EMS
Compliance with all relevant aspects of the
standard. (Radiated Emissions)
Compliance with all relevant aspects of the
standard. (ESD, RF electromagnetic field,
EFTB, Surge, RF conducted disturbances
and Power frequency magnetic field)
Notes for compliance to EMC regulation
Any device which utilizes a data communication function is susceptible
to the wider effects of local EMC noise. Therefore, when installing any
communication cables care should always be taken with the routing
and location of those cables. The GOT units identified on the previous
chapter are compliant with the EMC requirement when the following
communication cables are used.
GOT Unit Existing Cables User Made Cables
GT1055-QSBD
and
GT1050-QBBD
Ex.1
F = Ferrite core
Ex. NEC TOKIN - ESD-R-17S or similar
GT01-C30R48P modified as
shown in EX.1
Programmable
controller
140mm
(5.51inch)
Those cables need to be independently tested
by the user to demonstrate EMC compatibility
when they are used with Mitsubishi GOT unit
and FX3U Programmable Controllers.
GT01-C30R4-8P
(9.84inch)
F FF
Comes equipped
100mm250mm
(3.93inch)
Added by user
GOT units
General notes on Power supply
The GT1055-QSBD and GT1050-QBBD unit requires an additional
ferrite filter to be attached to the 24V DC power supply cables. The filter
should be attached in a similar manner as shown in the figure opposite,
i.e. the power cables are wrapped around the filter. However, as with all
EMC situations the more correctly applied precautions the better the
systems Electro-magnetic Compatibility. The ferrite recommended is a
TDK ZCAT3035-1330 or similar. The ferrite should be placed as near
to the 24VDC terminals of the GT1055-QSBD and GT1050-QBBD as
possible (which should be within 75mm of the GOT terminal).
Up to
75mm
(2.95inch)
GT105_ QUICK START MANUAL
GT10 5 0 -
Mitsubishi Electric Automation, Inc.
1.3 INCLUDED ITEMS
Product Name Model Name Specifications
GT1055-QSBD GOT main unit
GOT
GT1050-QBBD
(The maintenance supplies below are packed
with the product.)
ItemQuantity
Panel Mounting Bracket (with M4 X 20 screws)4
Panel Mounting Packing1
GT10 General Description Manual1
2. SPECIFICATIONS
2.1 MODEL NAME EXPLANATION
Power type
Panel color type
Display device type
ResolutionQ:320 × 240(QVGA)
Display color type
Screen size type
GOT1000 seriesGT10
2.2 GENERAL SPECIFICATIONS
ItemSpecifications
Operating
Ambient
Temp.
Storage Ambient
Temperature
Operating/Storage
ambient humidity
Vibration
Resistance
Shock Resistance
Operating
Atmosphere
Operating Altitude *1 2000m (6562 ft.) max.
Installation Location Inside control panel
Overvoltage
Category *2
Pollution Degree *3 2 or less
Cooling MethodSelf-cooling
1. Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude 0m
2. This indicates the section of the power supply to which the equipment is assumed to be
3. *his index indicates the degree to which conductive material is generated in the environment
Display
0 to 50°C
Section
Other
Than
0 to 55°C (When mounted horizontally), 0 to 50°C (When mounted vertically)
Display
Section
-20 to 60°C
10 to 90% RH, non-condensing
(The wet bulb temperature is 39°C or less.)
Conforms
to JIS
B3502 and
IEC61131-2
Conforms to JIS B3502, IEC 61131-2 (147 m/s², 11 ms, Sine half-wave pulse,
3 times each in the X, Y, and Z directions.)
Must be free of lamp black, corrosive gas, flammable gas, or excessive amount
of electro conductive dust particles and must be no direct sunlight. (Same as
for saving)
II or less
(0ft.). Failure to observe this instruction may cause a malfunction. When the air inside the control
panel is purged by pressurization, the surface sheet may be lifted by high pressure. As a result,
the touch panel may be difficult to press, and the sheet may be peeled off.
connected between the public electrical power distribution network and the machinery within
the premises. Category II applies to equipment for which electrical power is supplied from fixed
facilities. The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V.
where the equipment is used. In pollution degree 2, only non-conductive pollution occurs but
temporary conductivity may be produced due to condensation where the equipment is used.
In pollution degree 2, only non-conductive pollution occurs but temporary conductivity may be
produced due to condensation.
Backup TargetClock data, alarm history and recipe data
Battery
LifeApprox. 5 years (Operating ambient temperature of 25°C)
Buzzer Output (a buzzer
that sounds when touch
keys are pressed)
Environmental Protective
Structure *4
External Dimensions
W x H x D mm (inch)
RS-422/485
RS-232
Built-in Interface
USB
GT10-50FMBFor connecting GT10-50FMB memory board
Panel Cutting Dimensions (W x H) 153 x 121 (6.03 x 4.77) mm (inch) (Horizontal format)
Weight0.7kg (Excluding mounting fixtures)
Compatible Software
Package
16-dot standard font: 20 characters x 15 lines, 12-dot standard
font: 53 characters x 20 lines (Horizontal Format)
²
Approx. 50,000h. (Time for display intensity to become 1/5 at
operating ambient temperature of 25°C)
Cold cathode fluorescent tube (irreplaceable by a user)
backlight shutoff detection function is included. Backlight off/
screen saving time can be set.
Approx. 75,000h or longer
(Time for display intensity
reaches 50% at the operating
ambient temperature of 25°C)
Green light : Power is supplied
Orange light : Screen saving
Green / Orange flashing : Blown backlight bulb
POWER LED is not lit : Power is not supplied
Enable
Flash memory ROM (Internal), for storing project data
(3M bytes or less) and OS
SRAM (Internal), for storing alarm history, recipe data and time
action setting value
Single tone (LONG/ SHORT/ OFF adjustable)
Equivalent to IP67 (JEM1030) (front section)
164 x 135 x 56 (6.46 x 5.32 x 2.21)
(Excluding mounting fixtures) (Horizontal format)
Conforming to serial RS-422/485 standard, 1ch
Transmission speed: 115,200/57,600/38,400/19,200/9,600/
4,800bps
Connector shape: D-sub 9-pin (Female)
Application: PLC communication
Terminating resistor *5: Open/110Ω/330Ω (Switched by
Conforming to serial RS-232 standard, 1ch
Transmission speed: 115,200/57,600/38,400/19,200/9,600/4,8
00bps
Connector shape: D-sub 9-pin (Male)
Application: PLC communication, bar code reader connection,
PC communication (Project data upload/download, OS
installation, transparent function)
Conforming to serial USB (Full Speed 12Mbps), device, 1ch
Connector shape: Mini-B
Application: PC communication (Project data upload/download,
OS installation, transparent function)
GT Designer2 Version 2.90U or later/GT Designer3 Version
1.01B or later
]260 [cd/m²]
STN monochrome (white/blue)
liquid crystal
Monochrome (white/blue), 16
scales
Approx. 54,000h or longer
(Time for display intensity
reaches 50% at the operating
ambient temperature of 25°C)
5
GT105_ QUICK START MANUAL
Mitsubishi Electric Automation, Inc.
1. Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is
impossible to completely avoid this symptom, as the liquid crystal display comprises of a great
number of display elements. Flickers may be observed depending on the display color. Please
note that these dots appear due to its characteristic and are not caused by product defect.
• Flickers and partial discoloration may be generated on the liquid crystal display panel due to
the display contents or the contrast adjustment. However, please note that these phenomena
appear due to its characteristic and are not caused by product defect.
• There is a difference in the display brightness and the color tones between liquid crystal
display panels. When using multiple liquid crystal display panels, please note that there is an
individual difference between them.
• • A crosstalk (shadow as an extension of the display) may appear on the liquid crystal display
panel. Please note that it appears due to its characteristic.
• When the display section is seen from the outside of the display angle, the display color
seems like it has changed. Please note that it is due to its characteristic.
• Please note that the response time, brightness and color of the liquid crystal display
panel may vary depending on the usage environmental temperature. Especially in the low
temperature environment, the display response becomes slow due to the characteristics of
the STN liquid crystal. Please check the display response in advance for using this product.
• When the same screen is displayed for a long time, an incidental color or partial discoloration
is generated on the screen due to heat damage, and it may not disappear. To prevent heat
damage, the screen saver function is effective. F
2. Using the GOT Backlight OFF function can prolong the life of the backlight.
3. ROM in which new data can be written without deleting the written data.
4. Note that this does not guarantee all users’ operation environment. In addition, the product may
not be used in environments under exposition of oil or chemicals for a long period of time, or in
environments filled with oil-mist.
5. Set the terminating resistor selector switch of the GOT in accordance with the connection type
when adopting GOT multidrop connection. Gradation inversion is a characteristic of liquid crystal
displays. Please be forewarned that depending on the displayed color, the visualization may be
difficult even within the described view angle. Using the GOT Backlight OFF function can prolong
the life of the backlight. The touch panel is analog resistive film-type. If you touch the panel
simultaneously in 2 points or more, the switch that is located around the center of the touched
point, if any, may operate. Do not touch the panel in 2 points or more simultaneously. Do not
press the GOT display section with a pointed material as a pen or driver. Doing so can result
in a damage or failure of the display section. For the analog-resistive film type touch panels,
normally the adjustment is not required. However, the difference between a touched position
and the object position may occur as the period of use elapses. When any difference between
a touched position and the object position occurs, execute the touch panel calibration. When
any difference between a touched position and the object position occurs, other object may be
activated. This may cause an unexpected operation due to incorrect output or malfunction. ROM
in which new data can be written without deleting the written data. Set the terminating resistor
selector switch of the GOT in accordance with the connection type when adopting GOT multidrop
connection. Compliant with IP67 when the USB environmental protection cover is attached. Not
compliant when a USB cable is connected. Note that this does not guarantee all users’ operation
environment. The protection is not applied when the interface environment protection cover is
removed. In addition, the product may not be used in environments under exposition of oil or
chemicals for a long period of time, or in environments filled with oil-mist.
Appearance
White stripe patterns may appear on the surface of the resin molded part of the product. Please note
that these phenomena appear due to the characteristics of the material used in the product and are
not caused by product defect.
2.4 POWER SUPPLY SPECIFICATIONS
GT1055-QSBDGT1050-QBBD
Input power supply
voltage
Fuse (built-in, not
exchangeable)
Power Consumption (At
backlight off)
Inrush current15A or less (26.4VDC) 2ms
Permissible
instantaneous power
failure time *1
Noise immunity
Dielectric withstand
voltage
Insulation resistance
Grounding
*1 The GOT continues to operate even upon 5ms or shorter instantaneous power
failure. The GOT stops operating if there is extended power failure or voltage drop,
while it automatically resumes operation as soon as the power is restored.
6
24VDC (+10% -15%)
1.0A
9.84W (410mA/24VDC)
or less,
(4.32W (180mA/24VDC)
or less)
9.36W (390mA/24VDC)
or less,
(4.32W (180mA/24VDC)
or less)
Within 5ms
Noise voltage: 1000Vp-p, Noise width: 1µs (by noise
simulator of 30 to 100Hz noise frequency)
500VAC for 1 minute (across power supply terminals
and earth)
10MΩ or larger by insulation resistance tester (across
power supply terminals and earth)
Class D grounding (100Ω or less). To be connected
to the panel when grounding is not possible
3. HARDWARE SPECIFICATIONS
FRONT PANEL
1) 2)
3)
No. Name Description
Displays the utility screen and the user creation screen.
(1) Display section
(2) Touch panel
(3) POWER LED
BACK PANEL
No. Name Description
(1)
(2)
(3) USB interface
(4)USB coverOpen or close when using the USB interface
(5) Power terminal
(6)
(7)
(8)
(9) Battery coverOpen or close when replacing the battery.
For operating the touch switches in the utility screen and the
user creation screen
Green light: Power is supplied
Orange light: Screen saving (At backlight off)
Green / Orange flashing: Blown backlight bulb
POWER LED is not lit: Power is not supplied
7))1 )2
Battery cover opened
(Hardware version A to B)
10)
(Hardware version
C or later)
5) 6)3) 4) 11) 12)9)
13)
8)8)
For communicating with controller (PLC,
microcomputer board, bar code reader, etc) or
personal computer (OS installation, project data
download, transparent) (D-sub 9-pin male)
For communicating with controller (PLC,
microcomputer board, etc) (D-sub 9-pin female)
For PC connection (OS installation, project data
download, transparent) (Mini-B)
Power terminal and FG terminal (for power supply
(24VDC) to GOT and grounding)
Open or close when connecting a power terminal.
(Color: transparent) (Hardware version B or later)
-
Hole for the inserting installation fittings (accessory)
during the GOT installation to the panel (4 holes at top
and bottom)
Power supply
terminal layout
GT105_ QUICK START MANUAL
62(2.44")
(1.19")
Mitsubishi Electric Automation, Inc.
(10) Battery
history, recipe data and time action setting value (The
project data is stored in the built-in flash memory.)
GT11-50BAT battery for storing clock data, alarm
Memory board
(11)
(12)
(13)
cover
Memory board
interface
Terminating
resistor selector
switch (TERM.)
Remove when using the memory board.
Interface for mounting the memory board to the GOT.
Month
(example:Jan.)
1 (Jan.) to 9 (Sep.),
X (Oct.), Y (Nov.), Z (Dec.)
Connector
<Dec., 2009 or before>
2-digit
8
X
Month
(example: Oct.)
1 (Jan.) to 9 (Sep.),
X (Oct.), Y (Nov.), Z (Dec.
Year (example: 2008)
Last digit of year
6. INSTALLATION AND REMOVAL
6.1 CONTROL PANEL INSIDE DIMENSIONS FOR
MOUNTING GOT
Mount the GOT onto the control panel while considering the following
control panel inside dimensions.
Horizontal format.
30
(1.19")
152 (5.99")
120 (4.73")
140 (5.52")
Memory board connected
5. RATING PLATE
Example nameplate (manufacture's serial number 1010001)
GRAPHIC OPERATION TERMINAL
MODEL
IN 20.4
S/N
MITSUBISHI ELECTRIC CORPORATION
MADE IN JAPAN
<Jan., 2010 or later>
7-digit
0 1 10 0 0
<Dec., 2009 or before>
6-digit
9 X 0 0 0
Unit: mm(inch)
GT1055-QSBD
POWER 2.2W MAX
26.4VDC
1010001 AA
Actual product nameplate differs
*
from the example shown above.
1
Control number
Month (example: Jan.). 1 to 9: Jan. to Sep.,
X: Oct., Y: Nov., Z: Dec.
Year (example: 2010)
Last two digit of year
1
Control number
Month (example: Oct.). 1 to 9: Jan. to Sep.,
X: Oct., Y: Nov., Z: Dec.
Year (example: 2009)
Last digit of year
Unit:mm(inch)
Vertical format.
140 (5.52")
120 (4.73")
152 (5.99")
30
Unit:mm(inch)
Applicable cable
Some cables may need to be longer than the specified dimensions
when connecting to the GOT. Therefore, consider the connector
dimensions and bending radius of the cable as well for installation.
How to confirm production year and month
The production date of the optional replacement battery can be
confirmed by the lot No. marked on the nameplate (label) affixed on the
battery.
7
GT105_ QUICK START MANUAL
• Horizontal format• Vertical format
Mitsubishi Electric Automation, Inc.
6.2 PANEL CUTTING DIMENSIONS
Cut holes in the following dimensions on the panel. A space of top and
bottom is required to allow for the attachment of mounting fixtures.
A
BCC
Unit: mm(inch)
GOTA B C
GT105
153 (6.03")
(+2 (0.07"), 0 (0))
121 (4.77")
(+2 (0.07"), 0 (0))
B
10 (0.39") or
more
CC
A
Unit: mm(inch)
Panel Thickness
mm (inch)
Within 2 (0.07")
to 5 (0.19")
6.3 MOUNTING POSITION
When mounting the GOT, the following clearances must be maintained
from other structures and devices.
Horizontal position
Installation Environment AB C DE
In the presence of radiatednoise or heat-generating
equipment nearby
In the absence of radiatednoise or heat-generating
equipment nearby
B
50 mm
(1.97")
or more
20 mm
(0.79") or
more
80 mm
(3.14") or
more *1
20 mm
(0.79") or
more
Other device or control panel
50 mm
(1.97") or
more*2
20 mm
(0.79") or
more
50 mm
(1.97")
or more
20 mm
(0.79") or
more
100 mm
(3.93") or
more
20 mm
(0.79") or
more
Other device or control panel
B
C
ED
A
6.4 CONTROL PANEL INSIDE TEMPERATURE
AND MOUNTING ANGLE
When mounting the main unit to a control panel or similar fixture, set
the GOT display section as shown below.
Horizontal installation
When the temperature inside the control panel is 40° to 55°, the
mounting angle should be in the range from 60 to 105 degrees.
Vertical installation
When the temperature inside the control panel is 40° to 50°, the
mounting angle should be in the range from 60 to 105 degrees.
GOT
back
GOT
display
section
panel
105°
60°
Control
panel, etc.
The GOT will have a longer lifetime if used within the mounting angles
C
DE
shown above. Ideally, the temperature inside the control panel should
not exceed 0 to 40°C
6.5 INSTALLATION PROCEDURE
A
The GOT is designed to be embedded into a panel. Mount the GOT by
following the procedure below.
Vertical position
Installation Environment AB C DE
In the presence of radiatednoise or heat-generating
equipment nearby
In the absence of radiatednoise or heat-generating
equipment nearby
50 mm
(1.97")
or more
20 mm
(0.79") or
more
50 mm
(1.97")
or more
20 mm
(0.79") or
more
80 mm
(3.14") or
more *1
20 mm
(0.79") or
more
50 mm
(1.97")
or more
20 mm
(0.79") or
more
100 mm
(3.93") or
more
20 mm
(0.79") or
more
Cautions on the installation panel
Make sure that the panel surface is free from warpage, flaws and
irregularities. Warpage, flaws and irregularities may disable the
waterproof effect. Select proper panel thickness under consideration
of the panel strength. (For example, the panel strength may be
insufficient depending on the panel material and dimensions even
if the panel thickness is acceptable. Insufficient panel strength may
cause warpage depending on the installation positions of the GOT and
other equipment.) Installing the packing Install packing to the packing
installation groove on the back panel of the GOT. While referring to
the cross sectional view of the packing shown right, push the thinner
side into the packing groove. (Drawing below is the example of lateral
8
format.)
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.