Mitsubishi FX3U-4AD-PT-ADP, FX3U-FLROM-64, FX3U-4AD-TC-ADP, FX3U-232ADP-MB, FX3U-4DA-ADP Hardware Manual

...
-
FX3UC (D,DSS) SERIES
PROGRAMMABLE CONTROLLERS
HARDWARE MANUAL
This manual describes the part names, dimensions, mounting, cabling and specifications for t he product. This manual is extracted from FX3UC Series User's Manual - Hardware Edition. Refer to FX3UC Series User's Manual - Hardware Edition details. Before use, read this manual and manua ls of relevant products fu lly to acquire proficiency in the handling and operating the product. Make sure to learn all the product information, safety information, and precautions. And, store this manual in a safe place so that it can be taken out and read whenever necessary. Always forward it to the end user. Registration The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company.
Effective November 2007 Specifications are subject to change without notice.
© 2007 Mitsubishi Electric Corporation
Safety Precaution (Read these precautions before use.)
This manual classifies the safety precautions into two categories:
and .
Depending on the circumstances, procedures indicated by may also caus e severe injury. It is important to follow all precautions for personal safety.
Certification of UL, cUL standards
The FX3UC main units and input/output extension units/blocks supporting UL, cUL standards are as follows:
UL, cUL file number :E95239 Models : MELSEC FX
3U(C) series manufactured
FX
3UC-MT/D FX3UC-MT/DSS
Where  indicates:16,32,64,96 FX
3U-232ADP(-MB) FX3U-485ADP(-MB)
FX
3U-4AD-ADP FX3U-4DA-ADP
FX
3U-4AD-PT-ADP FX3U-4AD-TC-ADP
FX3UC-1PS-5V
Models : MELSEC FX2NC series manufactured
FX2NC-16EX(-DS) FX2NC-32EX(-DS) FX
2NC-16EYT(-DSS) FX2NC-32EYT(-DSS)
FX
2NC-16EX-T(-DS) FX2NC-16EYR-T(-DS)
Manual Number JY997D28601
Revision B
Date November 2007
Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.
STARTUP AND MAINTENANCE PRECAUTIONS
Do not touch any terminal while the PLC's power is on. Doing so may cause electric shock or malfunctions.
Before cleaning or retightening terminals, cut off all phases of the power supply externally. Failure to do so may cause electric shock.
Make sure to connect the battery for memory backup correctly. Do not charge, disassemble, heat, short-circuit, or expose the battery to fire. Doing so may rupture or ignite it.
Before modifying or disrupting the program in operation or running the PLC, carefully read through this manual and the associated manuals and ensure the safety of the operation. An operation error ma y damage the machinery or cause acciden ts.
STARTUP AND MAINTENANCE PRECAUTIONS
Turn off the power to the PLC before attaching or detaching the memory cassette. If the memory cassette is attached or detached while the PLC's power is on, the data in the memory may be destroyed, or the memory cassette may be damaged.
Do not disassemble or modify the PLC. Doing so may cause fire, equipment failures, or malfunctions. For repair, contact your local Mitsubishi Electric distributor.
Turn off the power to the PLC before connecting or disconnecting any extension cable. Failure to do so may cause equipment failures or malfunctions.
Turn off the power to the PLC before attaching or detaching the following devices. Failure to do so may cause equipment failures or malfunctions.
- Peripheral devices, extension blocks, connector conversion
adapter, extension power supply units, special adapters, and FX Series terminal blocks.
- Battery and memory cassettes
DISPOSAL PRECAUTIONS
Please contact a certified electronic waste disposal company for the environmentally safe recycling and disposal of your device.
TRANSPORT AND STORAGE PRECAUTIONS
Before transporting the PLC, turn on the power to the PLC to check that the BAT LED is off. If the PLC is transported with the BAT LED on or the battery exhausted, the battery-backed data may be unstable during transport ation.
The PLC is a precision instrument. During transportation, avoid impacts larger than those specified in Section 2.1. Failure to do so may cause failures in the PLC. After transportation, verify the operations of the PLC.
STARTUP AND MAINTENANCE PRECAUTIONS
Models : MELSEC FX2N series man ufactured
FX2N-8ER-ES/UL FX2N-8EX-ES/UL FX2N-8EYR-ES/UL FX2N-8EYT- ESS/UL FX2N-8EX-UA1/UL FX2N-16EX-ES/UL FX2N-16EYR-ES/UL FX2N-16EYT-ESS/UL FX2N-16EYS
Compliance with EC directive (CE Marking)
This document does not guarantee that a mechanical system including this product will comply with the following standards. Compliance to EMC directive and LVD directive of the entire mechanical system should be checked by the user / manufacturer. For more details please contact the local Mitsubishi Electric sales site.
Requirement for Compliance with EMC directive
The following products have shown compliance through direct testing (of the identified standards below) and design analysis (through the creation of a technical construction file) to the European Directive for Electromagnetic Compatibility (89/336/EEC) when used as directed by the appropriate documentation.
Type : Pro grammable Controller (Open Type Eq uipment) Models : MELSEC FX3U(C) series and FX2NC series
manufactured
from May 1st, 2005 FX3U-FLROM-16 FX3U-FLROM-64L from June 1st, 2005 FX3U-232ADP FX3U-485ADP
FX3U-4AD-ADP FX3U-4DA-ADP FX3U-4AD-PT-ADP FX3U-4AD-TC-A DP
FX3U-FLROM-64 from April 1st, 2007 FX3U-232ADP-MB FX3U-485ADP-MB from September 1st, 2007 FX3UC-MT/D FX3UC-MT/DSS
Where  indicates:16,32,64,96 from October 1st, 2007 FX3UC-1PS-5V
FX2NC-EX FX2NC-EYT
FX
2NC
-EX-DS FX
2NC
-EYT-DSS Where  indicates:16,32 FX
2NC
-16EX-T FX
2NC
-16EX-T-DS
Models : MELSEC F X2NC series manufactured
from March 1st, 1999 FX
2NC-EX-DS FX2NC- EYT-DSS
Where  indicates:16,32
from August 1st, 1999 FX
2NC-16EX-T-DS FX2NC-16EYR-T -DS
from October 1st, 2007 FX
2NC-EX F X2NC-EYT
Where  indicates:16,32 FX2NC-16EX-T FX2NC-16EYR-T
Models : MELSEC FX2N series manufactured
from July 1st, 1997 FX2N-16EX-ES/UL FX2N-16EYR-ES/UL
FX2N-16EYT-ESS/UL
from August 1st, 2005 FX2N-8ER-ES/UL FX2N-8EX-ES/UL
FX2N-8EYR-ES/UL FX2N-8EYT- ESS/UL
For the products above, PLC’s manufactured before March 31st, 2002 are compliant with EN50081-2 (EN61000­6-4) and EN50082-2 only. PLC’s manufactured from April 1st, 2002 to April 30th, 2006 are compliant with EN50081-2 (EN61000-6-4) and EN61131­2:1994+A11:1996+A12:2000 PLC’s manufactured after May 1st, 2006 are compliant with EN61131-2:2003
Standard Remark
EN61131-2:2003
Programmable controllers
- Equipment requirements and tests
Compliance with all relevant aspects of the standard. EMI
Radiated Emissions
Mains Terminal Voltage Emissions
EMS
RF immunity
Fast Transients
ESD
Surge
Voltage drops and interruptions
Conducted
Power magnetic fields
Standard Remark
EN61000-6-4:2001
- Generic emission standard Industrial environmen t
EN50081-2:1993
Electromagnetic compatibility
Compliance with all relevant aspects of the standard.
Radiated Emissions
Mains Terminal Voltage Emissions
EN61000-6-2:2001
- Generic immunity standard Industrial environmen t
Compliance with all relevant aspects of the standard.
RF immunity
Fast Transients
ESD
Conducted
Surge
Power magnetic fields
Voltage drops and interruptions
Standard Remark
EN61000-6-4:2001
- Generic emission standard Industrial environmen t
EN50081-2:1993
Electromagnetic compatibility
Compliance with all relevant aspects of the standard.
Radiated Emissions
Mains Terminal Voltage Emissions
EN50082-2:1995
Electromagnetic compatibility
- Generic immunity standard Industrial environment
Compliance with all relevant aspects of the standard.
RF immunity
Fast Tra nsients
ESD
Conducted
Power magnetic fields
EN61131-2:1994 /A11:1996 /A12:2000
Programmable controllers
- Equipment requirements and tests
Compliance with all relevant aspects of the standard.
RF Immunity
Fast Tra nsients
ESD
Damped oscillatory wave
JY997D28601B(ENGLISH)
Requirement for Compliance with LVD directive
The following products have shown compliance through direct testing (of the identified standards below) and design analysis (through the creation of a technical construction file) to the European Directive for Low Voltage (73/23/EEC) when used as directed by the appropriate documentation.
Type : Programmable Controller (Open Type Equipment) Models : MELSEC FX2NC series manufactured
from August 1st, 1999 FX2NC-16EYR-T-DS from October 1st, 2007 FX2NC-16EYR-T
*Compliance to BSEN61010-1 is claimed through virtue of direct
compliance to IEC1010-1 and Amendment 1.
Models :MELSEC FX2N series manufactured
from July 1st, 1997 FX2N-16EYR-ES/UL from August 1st, 2005 FX2N-8ER -ES/UL FX 2N-8EYR-ES/UL
For the products above, PLC’s manufactured before March 31st, 2002 are compliant with IEC1010-1 PLC’s manufactured from April 1st, 2002 to April 30th, 2006 are compliant with EN61131-2:1994+A11:1996+A12:2000 PLC’s manufactured after May 1st, 2006 are compliant with EN61131-2:2003
Caution for compliance with EC Directive
Installation in Enclosure
Programmable logic controllers are open-type devices that must be installed and used within conductive control boxes. Please use the FX3UC Series programmable logic controllers while installed in conductive shielded control boxes. Please secure the control box lid to the control box (for conduction). Installation within a control box greatly affects the safety of the system and aids in shielding noise from the programmable logic controller.
Caution for Analog Products in use
The analog special adapters have been found to be compliant to the European standards in the aforesaid manual and directive. However, for the very best performance from what are in fact delicate measuring and controlled output device Mitsubishi Electric would like to make the following points; As analog devices are sensitive by nature, their use should be considered carefully. For users of proprietary cables (integral with sensors or actuators), these users should follow the manufacturers’ installation requirements. Mitsubishi Electric recommends that shielded cables be used. If no other EMC protection is provided, then users may experience temporary loss of accuracy between +10%/-10% in very heavy industrial areas. However, Mitsubishi Electric suggests that when adequate EMC precautions are followed with general good EMC practice for the users complete control system, users should expect normal accuracy as specified in this manual.
- Sensitive analog cables should not be laid next to or bound with high voltage cabling. Where possible, users should run analog cables separately.
- Good cable shielding should be used. When grounding the shield - ensure that no loops are accidentally created.
- When reading analog values, EMC induced errors can be smoothed out by averaging the readings. This can be achieved either through functions on the analog special adapter/block or through the user’s program in the FX3UC Series PLC main unit.
Associated m anuals
FX3UC Series PLC (main unit) comes with this document (hardware manual). For a detailed explanation of the FX3UC Series hardware and information on PLC programming instructions and special extension unit/block, refer to the relevant documents.
EN61131-2:2003
Programmable controllers
- Equipment requirements and tests
Compliance with all relevant aspects of the standard.
Radiated Emissions
Mains Terminal Voltage Emissions
RF immunity
Fast Transients
ESD Surge
Voltage drops and interruptions
Conducted
Power magnetic fields
Standard Remark
IEC1010-1:1990
/A1:1992
BSEN61010-1 :1993 *
Safety requirements for electrical equipment for measurement, control, and laboratory use
- General requirements
The equipment has been assessed as a component for fitting in a suitable enclosure which meets the requirements of IEC 1010-1: 1990+A1:1992
Standard Remark
IEC1010-1:1990 /A1:1992
Safety requirements for electrical equipment for measurement, control, and laboratory use
- General requirements
The equipment has been assessed as a component for fitting in a suitable enclosure which meets the requirements of IEC 1010-1: 1990+A1:1992
EN61131-2:1994 :2003 /A12:2000 /A11:1996
Programmable controllers
- Equipment requirements
and tests
The equipment has been assessed as a component for fitting in a suitable enclosure which meets the requirements of EN61131-2: 1994+A11:1996+A12:2000, :2003
Standard Remark
Manual name Manual No. Description
FX3UC Series User's Manual
- Hardware Edition
JY997D28701
MODEL CODE:
09R519
Explains the FX3UC Series PLC specifications for I/O, wiring, installation, and maintenance.
FX3U/FX3UC Series Programming Manual
- Basic & Applied Instruction Edition
JY997D16601
MODEL CODE:
09R517
Describes PLC programming for basic/ applied instructions STL/ SFC programming and system devices.
FX Series User’s Manual - Data Communication Edition
JY997D16901
MODEL CODE:
09R715
Explains N:N Network, parallel link, computer link, non-protocol communication by RS instructions/FX
2N-232IF.
FX3U / FX3UC Series User's Manual
- Analog Control Edition
JY997D16701
MODEL CODE:
09R619
Describes specifications for analog control and programming methods for the FX3U / FX3UC Series PLC.
How to obtain manuals
For product manuals or documents, consult with the Mitsubishi Electric dealer from who you purchased your product.
Incorporated Items
Verify that the following product and items are included in the package.
1. Outline
1.1 Part names
FX3U / FX3UC Series User's Manual
- Positioning Control Edition
JY997D16801
MODEL CODE:
09R620
Explains the positioning control specifications of the FX3U / FX3UC Series and programming procedures
Included Items
Main units
FX3UC-MT/D
Product 1 unit
FX2NC-100MPCB [1m (3’ 3"), three wire]
1 cable
FX2NC-100BPCB [1m (3’ 3"), two wire]
1 cable
Manuals [Japanese version, English version]
1 manual
each
FX3UC-MT/DSS
Product 1 unit
FX2NC-100MPCB [1m (3’ 3"), three wire]
1 cable
Manuals [Japanese version, English version]
1 manual
each
Input / output extension blocks
FX2NC-EX FX2NC-16EX-T
Product 1 unit
FX2NC-10BPCB1 [0.1m (3.93"), double-ended]
1 cable
FX2NC-EX-DS FX2NC-16EX-T-DS FX2NC-EYT FX2NC-EYT-DSS FX2NC-16EYR-T FX2NC-16EYR-T-DS
Product 1 unit
Manual name Manual No. Description
[2]
[5]
Front panel
[11]
[6]
[12]
[2]
[8]
[4]
[2]
[6]
[14]
Under side
[4]
[15]
[7]
[9]
[10]
[6]
No. Name
[1] Memory cassette dummy cover
[2] Special adapter connecting hooks
[3] Special adapter connector cover
[4] DIN rail mounting hooks
[5]
POW LED On while power is on the PLC.
RUN LED On wh ile the PLC is running.
BAT LED Lights when the battery voltage drops.
ERR LED
Flashing when a program error occurs.
Lights when a CPU error occurs.
[6] FX2N C/FX3UC Extension block connecting hooks
[7] Input LED
[8] Output LED
[9] Input connector
[10] Out put connector
[11] Peripheral device connecting connector (RS-422)
[12] RUN/STOP switch
[13] FX2NC/FX3UC Extension block connecting connector cover
[14] Power connector for main unit
[15] Battery cover
Green Green
Red Red
[1]
[3]
Left side
[2]
[4]
[4]
[13]
Right side
[2]
[6]
[6]
Display LED
[5]
1.2 External dimensions/weight
Main units
FX2NC input/outpu t extension blocks (Connector t ype)
FX2NC input/outpu t extension blocks (Terminal bl ock type)
2. General specifications and Installation
For more details, refer to the FX3UC Series User's Manual -
Hardware Edition
Type
Model name
W:mm
(inches)
MASS
(Weight)
:
kg (lbs)
Main units
FX3UC-16MT/D(SS) 34.0 (1.34) 0.2 (0.44)
FX3UC-32MT/D(SS) 34.0 (1.34) 0.2 (0.44)
FX3UC-64MT/D(SS) 59.7 (2.36) 0.3 (0.66)
FX3UC-96MT/D(SS) 85.4 (3.37) 0.35 (0.77)
Input/output extension blocks (Connector type)
FX2NC-16EX(-DS) 14.6 (0.57) 0.15 (0.33)
FX2NC-32EX(-DS) 26.2 (1.03) 0.2 (0.44)
FX2NC-16EYT(-DSS) 14.6 (0.57) 0.15 (0.33)
FX2NC-32EYT(-DSS) 26.2 (1.03) 0.2 (0.44)
Input/output extension blocks (Terminal block type)
FX2NC-16EX-T(-DS) 20.2 (0.57) 0.15 (0.33)
FX2NC-16EYR-T(-DS) 24.2 (0.95) 0.2 (0.44)
Unit: mm(inches)
90(3.54")
74(2.91")
(13)
(0.52")
W
W
Unit: mm(inches)
90(3.54")
74(2.91")
(13)
(0.52")
W
Unit: mm(inches)
90(3.54")
74(2.91")
15
(0.6")
INSTALLATION PRECAUTIONS
Make sure to cut off all phases of the power supply externally before attempting installation or wiring work. Failure to do so may cause electric shock or damage to the product.
INSTALLATION PRECAUTIONS
Use the product within the generic environment specifications described in section 2.1 of this manual. Never use the product in areas with excessive dust, oily smoke, conductive dusts, corrosive gas (salt air, Cl2, H2S, SO2 or NO2), flammable gas, vibration or impacts, or expose it to high temperature, condensation, or rain and wind. If the product is used in such conditions, electric shock, fire, malfunctions, deterioration or damage may occur.
Do not touch the conductive parts of the product directly. Doing so may cause device failures or malfunctions.
Install the product securely using a DIN rail or mounting screws.
Install the product on a flat surface. If the mounting surface is rough, undue force will be applied to the PC board, thereby causing nonconformities.
When drilling screw holes or wiring, make sure that cutting and wiring debris do not enter the ventilation slits. Failure to do so may cause fire, equipment failures or malfunctions.
Be sure to remove the dust proof sheet from the PLC's ventilation port when installation work is completed. Failure to do so may cause fire, equipment failures or malfunctions.
Connect the extension cables, peripheral device cables, input/ output cables and battery connecting cable securely to their designated connectors. Unsecured connection may cause malfunctions.
Turn off the power before attaching or detaching the following devices. Failure to do so may cause device failures or malfunctions.
- Peripheral devices, extension blocks, connector conversion
adapter, extension power supply units, special adapters, and FX Series term inal blocks
- Battery and memory cassettes
Notes
When a dust proof sheet is supplied with an extension unit/ block, keep the sheet applied to the ventilation slits during installation and wiring work.
To prevent temperature rise, do not install the PLC on a floor, a ceiling or a vertical surface. Install it horizontally on a wall as shown in section 2.2.
Keep a space of 50mm (1.97”) or more between the unit main body and another device or structure (section 2.2 part A). Install the unit as far away as possible from high-voltage lines, high­voltage devices and power equipment.
2.1 Generic specif ications [Main unit]
*1 For common grounding, refer to section 3.2.
*2 The PLC cannot be used at a pressure higher than the
atmospheric pressure to avoid damage.
2.2 Installation lo cation
Install the PLC in an environment conforming to the generic specifications (section 2.1), installation precautions and notes.
For more details, r efer to FX3UC Series User's Manual -
Hardware Edition.
Installation location in enclosure
Space in enclosure
Extension devices can be connected on the left and right sides of the PLC main unit. If you intend to add extension devices in the future, keep extra space on the left and right sides open.
2.3 Procedures for installing to and d etaching from DIN rail
The main unit can be installed on a DIN46277 rail [35mm (1.38”) wide]. (It cannot be installed directly with screws.)
2.3.1 Installing methods
1) Turn the power supply OFF.
2) Push the DIN rail mounting hooks
1
of all connected units/blocks as
shown in the figure on the right .
Item Specification
Ambient temperature
0 to 55°C (32 to 131°F) when operating and -25 to 75°C (-13 to 167°F) when stored
Ambient humidity
5 to 95%RH (no condensation) when operating
Vibration resistance
Fre-
quency
(Hz)
Accel-
eration
(m/s2)
Half
ampli-
tude
(mm)
Sweep Count for X, Y, Z: 10 times (80 min. in each directio n)
When installed on DIN rail
10 to 57 - 0.035
57 to 150
4.9 -
Shock resistance
(147m/s2 Acceleration, Action time: 11ms, 3 times by half-sine pulse in each direction X, Y, and Z)
Noise resistance
By noise simulator at noise voltage of 1,000Vp-p, noise width of 1µs, rise time of 1ns and period of 30 to 100Hz
Dielectric withstand voltage
500V AC for one minute
Comply with JEM-1021
Between batch of all terminals and ground terminal
Insulation resistance
5M or more by 500V DC megger
Grounding
Class D grounding (grounding resistance: 100 or less) <Common grounding with a heavy electrical system is not allowed.>
*1
Working atmosphere
Free from corrosive or flammable gas and excessive conductive dusts
Working altitude
<2000m
*2
A
Configuration without extension cable
A
A
A
FX
3UC
Main unit
FX
2NC
-16EX
FX
2NC
-16EYT
50mm
(1.97")
A
Configuration with extension cable
FX
2N
-10PG
FX0N-65EC FX
0N
-30EC
FX2N-CNV-BC
Other
equipment
Other
equipment
Other
equipment
A
A
A
A
50mm
(1.97")
A
A
A
A
FX
3UC
Main unit
FX
2NC
-16EX
FX
2NC
-CNV-IF
FX
3U
-4AD-ADP
A
A
Loading...
+ 5 hidden pages