This manual describes the part names, dimensions, mounting, and specifications of the product. Before use, read this manual and the manuals of all relevant products fully to acquire proficiency in handling and operating the product. Make sure to learn all the product information, safety information, and precautions. Store this manual in a safe place so that it can be taken out and read whenever necessary. Always forward it to the end user. Registration: Ethernet is a trademark of Xerox Corporation. The company and product names described in this manual are registered trademarks or the trademarks of their respective companies.
Effective December 2016 Specifications are subject to change without notice.

Safety Precautions

This manual classifies the safety precautions into two categories:
Depending on the circumstances, procedures indicated by may also cause severe injury. It is important to follow all precautions for personal safety.

Associated Manuals

and .
Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.
Manual name Manual No. Description
3U-ENET-ADP
FX User's Manual
FX3S/FX3G/FX3GC/
3U/FX3UC Series
FX Programming Manual
- Basic & Applied Instruction Edition
3S Series
FX User’s Manual
- Hardware Edition
3G Series
FX User’s Manual
- Hardware Edition
3GC Series
FX User’s Manual
- Hardware Edition
3U Series
FX User’s Manual
- Hardware Edition
3UC Series
FX User’s Manual
- Hardware Edition
GX Works2 Version 1 Operating Manual (Common)
JY997D45801
MODEL CODE:
09R725
JY997D16601
MODEL CODE:
09R517
JY997D48601
MODEL CODE:
09R535
JY997D31301
MODEL CODE:
09R521
JY997D45401
MODEL CODE:
09R533
JY997D16501
MODEL CODE:
09R516
JY997D28701
MODEL CODE:
09R519
SH-080779ENG MODEL CODE:
13JU63
© 2012 Mitsubishi Electric Corporation
(Read these precautions before use.)
Describes details of the FX
Ethernet communication
ENET-ADP special adapter.
Describes PLC programming for basic/applied instructions and devices.
Explains FX3S Series PLC specifications for I/O, wiring, installation, and maintenance.
Explains FX3G Series PLC specifications for I/O, wiring, installation, and maintenance.
Explains FX3GC Series PLC specifications for I/O, wiring, installation, and maintenance.
Explains FX3U Series PLC specifications for I/O, wiring, installation, and maintenance.
Explains FX3UC Series PLC specifications for I/O, wiring, installation, and maintenance.
Explains the system configuration of GX Works2, the operation method of parameter setting and the online function, etc.
3U-
How to obtain manuals
For product manuals or documents, consult with the Mitsubishi Electric dealer from who you purchased your product.

Certification of UL, cUL standards

FX3U-ENET-ADP adapter comply with the UL standards (UL, cUL). UL, cUL File Number: E95239 Regarding the standards that comply with the main unit, please refer to either the FX series product catalog or consult with your nearest Mitsubishi product provider.

Compliance with EC directive (CE Marking)

This note does not guarantee that an entire mechanical module produced in accordance with the contents of this note will comply with the following standards. Compliance to EMC directive and LVD directive for the entire mechanical module should be checked by the user / manufacturer. For more information please consult with your nearest Mitsubishi product provider. Regarding the standards that comply with the main unit, please refer to either the FX series product catalog or consult with your nearest Mitsubishi product provider.
Requirement for Compliance with EMC directive
The following products have shown compliance through direct testing (of the identified standards below) and design analysis (through the creation of a technical construction file) to the European Directive for Electromagnetic Compatibility (2014/30/EU) when used as directed by the appropriate documentation.
Attention
This product is designed for use in industrial applications.
Type: Programmable Controller (Open Type Equipment) Models: MELSEC FX
from February 1st, 2012 FX
Standard Remark
EN61131-2:2007 Programmable controllers
- Equipment requirements and tests
Caution for EC Directive
Installation in Enclosure Programmable controllers are open-type devices that must be installed and used within conductive control cabinets. Please use the programmable controller while installed within a conductive shielded control cabinet. Please secure the cabinet door to the control cabinet (for conduction). Installation within a control cabinet greatly affects the safety of the system and aids in shielding noise from the programmable controller.
Control cabinet
- T he control cabinet must be conductive.
- G round the control cabinet with the thickest possible grounding cable.
- To ensure that there is electric contact between the control cabinet and its door, connect the cabinet and its doors with thick wires.
- I n order to suppress the leakage of radio waves, the control cabinet structure must have minimal openings. Also, wrap the cable holes with a shielding cover or other shielding devices.
- T he gap between the control cabinet and its door must be as small as possible by attaching EMI gaskets between them.
*1 These wires are used to improve the conductivity between the door and control
cabinet.
3U series manufactured
3U-ENET-ADP
Compliance with all relevan t aspects of the standard.
EMI
• Radiated E mission
• Condu cted Emission
EMS
• Radiated elect romagnetic field
• Fast transie nt burst
• Electrostatic discharge
• Hig h-energy surge
• Voltage drops and interruptions
• Condu cted RF
• Power frequency magnetic field
Shielding cover
Shielded cable
EMI gasket
Wires*

1. Outline

FX3U-ENET-ADP is an Ethernet adapter for the FX3S/FX3G/FX3GC/FX3U/FX3UC Series PLC that is compliant with 100BASE-TX/10BASE-T and has the features as follows.
1) Us ers can read and write data and programs from/to the PLC using MELSOFT products such as GX Works2 within the company LAN, etc.
2) Us ers can develop custom software to communicate with the PLC by using MC (MELSEC Communication) proto col (A-compatible 1E frame subset, fo r details, refer to user's manual). (TCP/IP or UDP/IP)
3) The FX
3U-ENET-ADP can be connected directly (simple connection) to GX
Works2 with only one Ethernet cable without using the hub.
4) Us ers can search "FX the find CPU function of GX Works2.
5) The FX
3U-ENET-ADP can automatically set the time of the main unit using the
time setting function.
6) The FX
3U-ENET-ADP parameters can be set easily using GX Works2.
7) The diagnostic functions of GX Works2 enables easy diagnostics and troubleshooting of the FX
8) Us ers can monitor the information and device values stored in the main unit and FX
3U-ENET-ADP from a browser in a personal computer using the data
monitoring function.

1.1 Incorporated Items

Verify that the following product and items are included in the package:
Product FX3U-ENET-ADP Ethernet communication special adapter
Accessories Installation Manual (This manual)

1.2 External Dimensions and Each Part Names

[1]
7 (0.28)
DIN rail mounting groove
[1]
(DIN rail: DIN46277, 35mm (1.38") width)
[2] Nameplate [7]
Direct mounting hole
[3]
2 holes of 4.5 (0.18") (mounting screw: M4 screw)
[4] Status LEDs [9] DIN rail mounting hook
[5] Special adapter fixing hook
3U-ENET-ADP + Main unit" connected in the network using
3U-ENET-ADP.
[2]
81.5 (3.21)
[3]
20.5
(0.81)
23 (0.91)
Unit: mm (inches) MASS (Weight): Approx. 0.1 kg (0.22 lbs)
[6] Special adapter connector
10BASE-T/100BASE-TX connector (RJ45)
External ground terminal (M2.5
[8]
terminal block screw)
[5][4]
90 (3.55)
98 (3.86)
(mounting hole pitch)
106 (4.18)
[6] [7]
[8]
[9]

1.3 Indications of LEDs

LED
LED
display
POWER Green
100M Green
SD/RD Green
ERR. Red
OPEN Green

2. Installation

For installation details, refer to the following manuals.
INSTALLATION PRECAUTIONS
Make sure to cut off all phases of the power supply externally before attempting installation work. Failure to do so may cause electric shock.
INSTALLATION PRECAUTIONS
Use the product within the generic environment specifications described in PLC main unit manual (Hardware Edition). Never use the product in areas with excessive dust, oily smoke, conductive dusts, corrosive gas (salt air, Cl vibration or impacts, or expose it to high temperature, condensation, or rain and wind. If the product is used in such conditions, electric shock, fire, malfunctions, deterioration or damage may occur.
Do not touch the conductive parts of the product directly. Doing so may cause device failures or malfunctions.
Install the product securely using a DIN rail or mounting screws.
Install the product on a flat surface.
If the mounting surface is rough, undue force will be applied to the PC board, thereby causing nonconformities.
When drilling screw holes or wiring, make sure that cutting and wiring debris do not enter the ventilation slits. Failure to do so may cause fire, equipment failures or malfunctions.
Connect the FX Loose connections may cause malfunctions.

2.1 Connection to the PLC

A connector conversion adapter is required to connect the special adapters with
3S/FX3G PLCs.
FX An expansion board is required to connect the special adapters with the FX
3UC-32MT-LT(-2) PLCs.
FX For installation method to PLCs, refer to the User's Manual - Hardware Edition of the connected PLC.
Connection precautions
Only one FX3U-ENET-ADP unit can be connected in the final stage (leftmost position) of the main unit, special adapter, etc.
Connect all the high-speed I/O special adapters before con necting other special adapters when they are used in combination. Do not connect a high-speed I/O special adapter on the left side of any special adapters other than other high-speed I/O special adapters.

2.2 Mounting

The product is mounted by the following method.
DIN rail mounting
Direct mounting (mounting screw: M4 screw)
For details, refer to the User's Manual - Hardware Edition of the connected PLC.
Status Description
color
ON Power is on
OFF Power is off
ON 100Mbps communication
OFF 10Mbps communication or not connected
ON Data being sent or received.
OFF Data is not sent or received.
ON Setting errors, hardware errors, etc.
Flicker Communication errors
OFF Setting normal, communication normal
TCP/IP: 1 or more connections are established.
ON
UDP: 1 or more connections are open.
TCP/IP: All connections are unestablished.
OFF
UDP: All connections are closed.
Refer to the FX
3U-ENET-ADP securely to special adapter connector.
3U-ENET-ADP User's Manual.
2, H2S, SO2 , or NO2), flammable gas,
3U/

3. Wiring

WIRING PRECAUTIONS
Make sure to cut off all phases of the power supply externally before attempting installation or wiring work. Failure to do so may cause electric shock or damage to the product.
WIRING PRECAUTIONS
Perform class D grounding (grounding resistance: 100Ω or less) to the grounding terminal on the FX
area 0.5 to 1.5mm Do not use common grounding with heavy electrical systems (refer to the Section 3.2).
When drilling screw holes or wiring, make sure that cutting and wiring debris do not enter the ventilation slits. Failure to do so may cause fire, equipment failures or malfunctions.
Make sure to properly wire to the terminal block (European type) in accordance with the following precautions. Failure to do so may cause electric shock, equipment failures, a short-circuit, wire breakage, malfunctions, or damage to the product.
- The disposal size of the cable end should follow the dimensions described in the manual.
- Tightening torque should follow the specifications in the manual.
- Twist the end of strand wire and make sure that there are no loose wires.
- Do not solder-plate the electric wire ends.
- Do not connect more than the specified number of wires or electric wires of unspecified size.
- Affix the electric wires so that neither the terminal block nor the connected parts are directly stressed.
Make sure to observe the following precautions in order to prevent any damage to the machinery or accidents due to abnormal data written to the PLC under the influence of noise:
1) Do not bundle the main ci rcuit line together with or lay it close to the main circuit, high-voltage line or load line. Otherwise, noise disturbance and/or surge induction are likely to take place. As a guideline, lay the control lin e at least 100mm (3.94") or more away from the main circuit or high-voltage lines.
2) Ground the shield w ire or shield of the shielded cable at one point on the PLC. However, do not use common grounding with heavy electrical systems.

3.1 Applicable Connector and Cable

3.1.1 Applicable connector

RJ45 type modular jack

3.1.2 Pin Configuration

The pin configuration of FX3U-ENET-ADP RJ45 type modular jack is as follows:
81

3.1.3 Applicable cable

10BASE-T
100BASE-TX
A straight cable is used. A cross cable can al so be used when using direct connection (simple connection) between the personal computer and the FX3U-ENET-ADP.
Cable conforming to Ether net standard practice: Category 3 or better (STP cable)
Cable conforming to Ether net standard practice: Category 5 or better (STP cable)

3.2 Grounding

Other
equipment
Independent grounding
Best
3U-ENET-ADP with a wire of cross-sectional
2
.
Pin No. Signal Direction Contents
1 TD+ Out + side of sending data
2TD Out − side of sending data
3 RD+ In + side of receiving data
4 Not used -
5 Not used -
6RD In − side of receiving data
7 Not used -
8 Not used -
Other
equipment
Shared grounding
Good
PLCPLCPLC
equipment
Common grounding
Not allowed
Other
Terminal block arrangement
Terminal name Content
Perform class D grounding.
(Ground terminal)
Grounding wiring
Example usage of FX
Ethernet
modular jack
(RJ45)
Ground cable
Electric wire size
Terminal screw M2.5
Tightening torque
*1 When tightening a grounding terminal, use a screwdriver suitable for the terminal
screw. The screwdriver which does not suit the thread groove is used, tightening torque will not be able to be achieved. To achiev e the appropriate tightening torque shown in the upper table, use the following screwdriver or an appropriate replacement. <Reference>
Weidmuller Interface GmbH & Co. KG SDIK PH0 9008560000
Weidmuller Interface GmbH & Co. KG SD 0.6×3.5×100 9008330000

4. Specification

For details on specifications, refer to the following manual.
DESIGN PRECAUTIONS
Make sure to have the following safety circuits outside the PLC to ensure safe system operation even during external power supply problems or PLC failure. Otherwise, malfunctions may cause serious accidents.
1) Most importantly, have the followin g: an emergency stop circuit, a protection
circuit, an interlock circuit for opposite movements (such as normal vs. reverse rotation), and an interlock circuit (to prevent damage to the equipment at the upper and lower positioning limits).
2) Note that when the PLC CPU detects an error, such as a watchdog timer
error, during self-diagnosis, all outputs are turned off. Also, when an error that cannot be detected by the PLC main unit occurs in an input/output control block, output control may be disabled. External circuits and mechanisms should be designed to ensure safe machinery operation in such cases.
DESIGN PRECAUTIONS
Make sure to observe the following precautions in order to prevent any damage to the machinery or accidents due to abnormal data written to the PLC under the influence of noise:
1) Do not bundle the control line together with or lay it close to the main circuit or
power line. As a guideline, lay the control line at least 100mm (3.94") or more away from the main circuit or power line. Noise may cause malfunctions.
2) Ground the shield wire or shield of a shielded cable. Do not use common
grounding with heavy electrical systems.
STARTUP AND MAINTENANCE PRECAUTIONS
Do not touch any terminals or connector while the PLC's power is on. Doing so may cause electrical shock or malfunctions.
Before cleaning or retightening screws, externally cut off all phases of the power supply. Failure to do so may cause malfunction or failure of the special adapter. When the screws are tightened insufficiently, they may fall out and cause a shortcircuit or malfunction. When tightened too much, the screws or the special adapter may be damaged, resulting in short-circuit, or malfunction.
When controlling the PLC (especially when changing data, the program or changing the operating conditions) during operation, ensure that it is safe to do so.
(Grounding resistance: 100Ω or less)
3U
D Grounding (100Ω or less)
FX
3U
FX
3U-
ENET-ADP
2
0.5 to 1.5mm
*1
0.4 to 0.5N•m
Manufacturer Model name Model number
(AWG20 to 16)
FX
3U-ENET-ADP User's Manual
STARTUP AND MAINTENANCE PRECAUTIONS
Do not disassemble or modify the special adapter. Doing so may cause fire, equipment failures, or malfunctions.
The special adapter case is made of resin. If dropped or subjected to strong impact, the special adapter may be damaged.
When the special adapter is installed or removed from the panel, make sure to externally cut off all phases of the power su pply. Failure to do so may cause malfunction or failure of the special adapter.
DISPOSAL PRECAUTIONS
Please contact a certified electronic waste disposal company for the environmentally safe recycling and disposal of your device.
TRANSPORT AND STORAGE PRECAUTIONS
The product is a precision instrument. During transportation, avoid impacts larger than those specified in the general specifications by using dedicated packaging boxes and shock-absorbing palettes. Failure to do so may cause failures in the product. After transportation, verify operation of the product and check for damage of the mounting part, etc.

4.1 Applicable PLC

Model name Applicability Number of connectable units
3S Series PLC
FX
3G Series PLC
FX
3GC Series PLC Ver. 2.00 or later One unit
FX
3U Series PLC
FX
3UC Series PLC
FX
The version number can be checked by reading the last three digits of device D8001 or D8101.
*1 A connector conversion adapter is required to connect the FX
FX
*2 The FX
An expansion board is required to connect the FX3U-ENET-ADP with the FX3U/
*3
FX
*1*2
Ver. 1.00 or later One unit
*1
Ver. 2.00 or later One unit
*3
Ver. 3.10 or later One unit
*3
Ver. 3.10 or later One unit
3S/FX3G PLCs.
3S PLC is supported by FX3U-ENET-ADP Ver. 1.20 or later.
3UC-32MT-LT(-2) PLCs.
3U-ENET-ADP with

4.2 Related software

Software Model name Applicable software version
GX Works2 (SW DNC-GXW2-E)
*1 GX Works2 Ver. 1.87R or later supports the data monitoring function setting.
Parameter setting of FX

4.3 General Specifications

Items other than the following are equivalent to those of the PLC main unit. For general specifications, refer to the User's Manual - Hardware Edition of the connected PLC.
Item Specification
Dielectric withstand voltage
Insulation resistance
FX
3S Series PLC Ver. 1.492N or later
3G/FX3GC Series PLC Ver. 1.87R or later
FX
3U/FX3UC Series PLC Ver. 1.73B or later
FX
3U-ENET-ADP etc. can be performed by GX Works2.
500V AC for one minute
5MΩ or higher by 500V DC insulation resistance tester
Between all PLC terminals and ground terminal
*1

4.4 Power Supply Specification

Item Specification
Driving power supply
Since driving power supply (current consumption) specifications differ for other special adapters, please take the power capacity of the main unit into consideration. For system configuration information (calculation of the power supply capacity of the main unit etc.), refer to the User's Manual - Hardware Edition of the connected PLC.
30mA / 5V DC
power is supplied internally from t he main unit.
5V DC

4.5 Communication Specification

Item Specification
Data transmission speed 100Mbps/10Mbps
Transmission specifications
Communication method Full-duplex/Half-duplex
Transmission method Base band
Maximum segment length 100m (328’1’’)

4.6 Functions

Item Specification
MELSOFT connections
Communication Using MC Protocol
MELSOFT Direct Connection (Simple Connection)
Functions
Number of simultaneously open connections allowed
Number of connectable units to the main unit
*1 The time setting function (SNTP client) is enabled only after the trigger
condition is established.
*2 The
FX3U-ENET-ADP occupies 1 communication channel in the same way
as communication expansion boards and other communication special adapters.
Find CPU function
Time setting function
Diagnostics function from MELSOFT
Data monitoring function
MELSOFT connection + MC protocol + Data monitoring <= 4
*2
1 unit
*1

5. 「电器电子产品有害物质限制使用标识要求」的表示方式

Note: This symbol mark is for China only.
含有有害6物质的名称,含有量,含有部品  本产品中所含有的有害6 物质的名称,含有量,含有部品如下表
所示。
产品中有害物质的名称及含量
有害物质
部件名称
外壳
可编程 控制器
印刷基板 ×
(Pb)汞(Hg)镉(Cd)
六价铬
(Cr(VI))
多溴联苯
(PBB)
多溴 二苯醚 (PBDE)
本表格依据SJ/T 11364的规定编制。
○:表示该有害物质在该部件所有均质材料中的含量均在GB/T
26572规定的限量要求以下。
×: 表示该有害物质至少在该部件的某一均质材料中的含量超出 GB/T
26572规定的限量要求。
This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.
Warranty
Exclusion of loss in opportunity and secondary loss from warranty liability Regardless of the grat is warranty term, Mitsubishi shall not be liable for compensation to: (1) Damages caused by any cause found not to be the responsibility of Mitsubishi. (2)
Loss in opport unity, lost profits inc urred to the user by Failures of Mitsubishi products.
Special damages and secondary damages w hether foreseeable or not, compensa tion for accidents, and compensation for damages to products other than Mitsubishi products.
(4) Replacement by the user, maintenance of on-site equipment, start-up test run
and other tasks.
For safe use
This product has been manufactured as a general-purpose part for general
industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life. Before using the product for special purposes such as nuclear power, electric
power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi Electric.
This product has been manufactured under strict quality control. However when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
Loading...
+ 1 hidden pages