JY997D47401D
Side
B
Side
JAPANESE
A
Side
ENGLISH
B
FX3U-ENET-ADP
INSTALLATION MANUAL
Manual Number JY997D47401
Revision D
Date December 2016
This manual describes the part names, dimensions, mounting, and specifications
of the product. Before use, read this manual and the manuals of all relevant
products fully to acquire proficiency in handling and operating the product. Make
sure to learn all the product information, safety information, and precautions.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.
Registration:
Ethernet is a trademark of Xerox Corporation.
The company and product names described in this manual are registered
trademarks or the trademarks of their respective companies.
Effective December 2016
Specifications are subject to change without notice.
Safety Precautions
This manual classifies the safety precautions into two categories:
Depending on the circumstances, procedures indicated by may
also cause severe injury.
It is important to follow all precautions for personal safety.
Associated Manuals
and .
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
Manual name Manual No. Description
3U-ENET-ADP
FX
User's Manual
FX3S/FX3G/FX3GC/
3U/FX3UC Series
FX
Programming Manual
- Basic & Applied
Instruction Edition
3S Series
FX
User’s Manual
- Hardware Edition
3G Series
FX
User’s Manual
- Hardware Edition
3GC Series
FX
User’s Manual
- Hardware Edition
3U Series
FX
User’s Manual
- Hardware Edition
3UC Series
FX
User’s Manual
- Hardware Edition
GX Works2 Version 1
Operating Manual
(Common)
JY997D45801
MODEL CODE:
09R725
JY997D16601
MODEL CODE:
09R517
JY997D48601
MODEL CODE:
09R535
JY997D31301
MODEL CODE:
09R521
JY997D45401
MODEL CODE:
09R533
JY997D16501
MODEL CODE:
09R516
JY997D28701
MODEL CODE:
09R519
SH-080779ENG
MODEL CODE:
13JU63
© 2012 Mitsubishi Electric Corporation
(Read these precautions before use.)
Describes details of the FX
Ethernet communication
ENET-ADP
special adapter.
Describes PLC programming for
basic/applied instructions and
devices.
Explains FX3S Series PLC
specifications for I/O, wiring,
installation, and maintenance.
Explains FX3G Series PLC
specifications for I/O, wiring,
installation, and maintenance.
Explains FX3GC Series PLC
specifications for I/O, wiring,
installation, and maintenance.
Explains FX3U Series PLC
specifications for I/O, wiring,
installation, and maintenance.
Explains FX3UC Series PLC
specifications for I/O, wiring,
installation, and maintenance.
Explains the system configuration of
GX Works2, the operation method of
parameter setting and the online
function, etc.
3U-
How to obtain manuals
For product manuals or documents, consult with the Mitsubishi Electric dealer from
who you purchased your product.
Certification of UL, cUL standards
FX3U-ENET-ADP adapter comply with the UL standards (UL, cUL).
UL, cUL File Number: E95239
Regarding the standards that comply with the main unit, please refer to either the FX
series product catalog or consult with your nearest Mitsubishi product provider.
Compliance with EC directive (CE Marking)
This note does not guarantee that an entire mechanical module produced in
accordance with the contents of this note will comply with the following standards.
Compliance to EMC directive and LVD directive for the entire mechanical module
should be checked by the user / manufacturer. For more information please consult
with your nearest Mitsubishi product provider.
Regarding the standards that comply with the main unit, please refer to either the FX
series product catalog or consult with your nearest Mitsubishi product provider.
Requirement for Compliance with EMC directive
The following products have shown compliance through direct testing (of the identified
standards below) and design analysis (through the creation of a technical construction
file) to the European Directive for Electromagnetic Compatibility (2014/30/EU) when
used as directed by the appropriate documentation.
Attention
This product is designed for use in industrial applications.
Type: Programmable Controller (Open Type Equipment)
Models: MELSEC FX
from February 1st, 2012 FX
Standard Remark
EN61131-2:2007
Programmable controllers
- Equipment requirements
and tests
Caution for EC Directive
• Installation in Enclosure
Programmable controllers are open-type devices that must be installed and used
within conductive control cabinets. Please use the programmable controller while
installed within a conductive shielded control cabinet. Please secure the cabinet
door to the control cabinet (for conduction). Installation within a control cabinet
greatly affects the safety of the system and aids in shielding noise from the
programmable controller.
• Control cabinet
- T he control cabinet must be conductive.
- G round the control cabinet with the thickest possible grounding cable.
- To ensure that there is electric contact between the control cabinet and its door,
connect the cabinet and its doors with thick wires.
- I n order to suppress the leakage of radio waves, the control cabinet structure
must have minimal openings. Also, wrap the cable holes with a shielding cover
or other shielding devices.
- T he gap between the control cabinet and its door must be as small as possible
by attaching EMI gaskets between them.
*1 These wires are used to improve the conductivity between the door and control
cabinet.
3U series manufactured
3U-ENET-ADP
Compliance with all relevan t aspects of the
standard.
EMI
• Radiated E mission
• Condu cted Emission
EMS
• Radiated elect romagnetic field
• Fast transie nt burst
• Electrostatic discharge
• Hig h-energy surge
• Voltage drops and interruptions
• Condu cted RF
• Power frequency magnetic field
Shielding cover
Shielded cable
EMI gasket
Wires*
1. Outline
FX3U-ENET-ADP is an Ethernet adapter for the FX3S/FX3G/FX3GC/FX3U/FX3UC
Series PLC that is compliant with 100BASE-TX/10BASE-T and has the features as
follows.
1) Us ers can read and write data and programs from/to the PLC using MELSOFT
products such as GX Works2 within the company LAN, etc.
2) Us ers can develop custom software to communicate with the PLC by using MC
(MELSEC Communication) proto col (A-compatible 1E frame subset, fo r details,
refer to user's manual). (TCP/IP or UDP/IP)
3) The FX
3U-ENET-ADP can be connected directly (simple connection) to GX
Works2 with only one Ethernet cable without using the hub.
4) Us ers can search "FX
the find CPU function of GX Works2.
5) The FX
3U-ENET-ADP can automatically set the time of the main unit using the
time setting function.
6) The FX
3U-ENET-ADP parameters can be set easily using GX Works2.
7) The diagnostic functions of GX Works2 enables easy diagnostics and
troubleshooting of the FX
8) Us ers can monitor the information and device values stored in the main unit and
FX
3U-ENET-ADP from a browser in a personal computer using the data
monitoring function.
1.1 Incorporated Items
Verify that the following product and items are included in the package:
Product FX3U-ENET-ADP Ethernet communication special adapter
Accessories Installation Manual (This manual)
1.2 External Dimensions and Each Part Names
[1]
7 (0.28″)
DIN rail mounting groove
[1]
(DIN rail: DIN46277, 35mm (1.38")
width)
[2] Nameplate [7]
Direct mounting hole
[3]
2 holes of 4.5 (0.18")
(mounting screw: M4 screw)
[4] Status LEDs [9] DIN rail mounting hook
[5] Special adapter fixing hook
3U-ENET-ADP + Main unit" connected in the network using
3U-ENET-ADP.
[2]
81.5 (3.21″)
[3]
20.5
(0.81″)
23 (0.91″)
Unit: mm (inches)
MASS (Weight): Approx. 0.1 kg (0.22 lbs)
[6] Special adapter connector
10BASE-T/100BASE-TX
connector (RJ45)
External ground terminal (M2.5
[8]
terminal block screw)
[5][4]
90 (3.55″)
98 (3.86″)
(mounting hole pitch)
106 (4.18″)
[6]
[7]
[8]
[9]
1.3 Indications of LEDs
LED
LED
display
POWER Green
100M Green
SD/RD Green
ERR. Red
OPEN Green
2. Installation
For installation details, refer to the following manuals.
INSTALLATION
PRECAUTIONS
• Make sure to cut off all phases of the power supply externally before
attempting installation work.
Failure to do so may cause electric shock.
INSTALLATION
PRECAUTIONS
• Use the product within the generic environment specifications described in
PLC main unit manual (Hardware Edition).
Never use the product in areas with excessive dust, oily smoke, conductive
dusts, corrosive gas (salt air, Cl
vibration or impacts, or expose it to high temperature, condensation, or rain
and wind.
If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur.
• Do not touch the conductive parts of the product directly.
Doing so may cause device failures or malfunctions.
• Install the product securely using a DIN rail or mounting screws.
• Install the product on a flat surface.
If the mounting surface is rough, undue force will be applied to the PC board,
thereby causing nonconformities.
• When drilling screw holes or wiring, make sure that cutting and wiring debris
do not enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.
• Connect the FX
Loose connections may cause malfunctions.
2.1 Connection to the PLC
A connector conversion adapter is required to connect the special adapters with
3S/FX3G PLCs.
FX
An expansion board is required to connect the special adapters with the FX
3UC-32MT-LT(-2) PLCs.
FX
For installation method to PLCs, refer to the User's Manual - Hardware Edition of
the connected PLC.
Connection precautions
Only one FX3U-ENET-ADP unit can be connected in the final stage (leftmost
position) of the main unit, special adapter, etc.
Connect all the high-speed I/O special adapters before con necting other
special adapters when they are used in combination.
Do not connect a high-speed I/O special adapter on the left side of any
special adapters other than other high-speed I/O special adapters.
2.2 Mounting
The product is mounted by the following method.
• DIN rail mounting
• Direct mounting (mounting screw: M4 screw)
For details, refer to the User's Manual - Hardware Edition of the connected PLC.
Status Description
color
ON Power is on
OFF Power is off
ON 100Mbps communication
OFF 10Mbps communication or not connected
ON Data being sent or received.
OFF Data is not sent or received.
ON Setting errors, hardware errors, etc.
Flicker Communication errors
OFF Setting normal, communication normal
TCP/IP: 1 or more connections are established.
ON
UDP: 1 or more connections are open.
TCP/IP: All connections are unestablished.
OFF
UDP: All connections are closed.
→ Refer to the FX
3U-ENET-ADP securely to special adapter connector.
3U-ENET-ADP User's Manual.
2, H2S, SO2 , or NO2), flammable gas,
3U/

3. Wiring
WIRING
PRECAUTIONS
• Make sure to cut off all phases of the power supply externally before
attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
WIRING
PRECAUTIONS
• Perform class D grounding (grounding resistance: 100Ω or less) to the
grounding terminal on the FX
area 0.5 to 1.5mm
Do not use common grounding with heavy electrical systems (refer to the
Section 3.2).
• When drilling screw holes or wiring, make sure that cutting and wiring debris
do not enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.
• Make sure to properly wire to the terminal block (European type) in
accordance with the following precautions.
Failure to do so may cause electric shock, equipment failures, a short-circuit,
wire breakage, malfunctions, or damage to the product.
- The disposal size of the cable end should follow the dimensions described
in the manual.
- Tightening torque should follow the specifications in the manual.
- Twist the end of strand wire and make sure that there are no loose wires.
- Do not solder-plate the electric wire ends.
- Do not connect more than the specified number of wires or electric wires
of unspecified size.
- Affix the electric wires so that neither the terminal block nor the connected
parts are directly stressed.
• Make sure to observe the following precautions in order to prevent any
damage to the machinery or accidents due to abnormal data written to the
PLC under the influence of noise:
1) Do not bundle the main ci rcuit line together with or lay it close to the main
circuit, high-voltage line or load line.
Otherwise, noise disturbance and/or surge induction are likely to take
place. As a guideline, lay the control lin e at least 100mm (3.94") or more
away from the main circuit or high-voltage lines.
2) Ground the shield w ire or shield of the shielded cable at one point on the
PLC. However, do not use common grounding with heavy electrical
systems.
3.1 Applicable Connector and Cable
3.1.1 Applicable connector
• RJ45 type modular jack
3.1.2 Pin Configuration
The pin configuration of FX3U-ENET-ADP RJ45 type modular jack is as follows:
81
3.1.3 Applicable cable
10BASE-T
100BASE-TX
A straight cable is used. A cross cable can al so be used when using direct connection
(simple connection) between the personal computer and the FX3U-ENET-ADP.
Cable conforming to Ether net standard practice:
Category 3 or better (STP cable)
Cable conforming to Ether net standard practice:
Category 5 or better (STP cable)
3.2 Grounding
Other
equipment
Independent grounding
Best
3U-ENET-ADP with a wire of cross-sectional
2
.
Pin No. Signal Direction Contents
1 TD+ Out + side of sending data
2TD− Out − side of sending data
3 RD+ In + side of receiving data
4 Not used -
5 Not used -
6RD− In − side of receiving data
7 Not used -
8 Not used -
Other
equipment
Shared grounding
Good
PLCPLCPLC
equipment
Common grounding
Not allowed
Other
Terminal block arrangement
Terminal name Content
Perform class D grounding.
(Ground terminal)
Grounding wiring
Example usage of FX
Ethernet
modular jack
(RJ45)
Ground cable
Electric wire size
Terminal screw M2.5
Tightening torque
*1 When tightening a grounding terminal, use a screwdriver suitable for the terminal
screw. The screwdriver which does not suit the thread groove is used, tightening
torque will not be able to be achieved. To achiev e the appropriate tightening
torque shown in the upper table, use the following screwdriver or an appropriate
replacement.
<Reference>
Weidmuller Interface GmbH & Co. KG SDIK PH0 9008560000
Weidmuller Interface GmbH & Co. KG SD 0.6×3.5×100 9008330000
4. Specification
For details on specifications, refer to the following manual.
DESIGN
PRECAUTIONS
• Make sure to have the following safety circuits outside the PLC to ensure safe
system operation even during external power supply problems or PLC failure.
Otherwise, malfunctions may cause serious accidents.
1) Most importantly, have the followin g: an emergency stop circuit, a protection
circuit, an interlock circuit for opposite movements (such as normal vs.
reverse rotation), and an interlock circuit (to prevent damage to the equipment
at the upper and lower positioning limits).
2) Note that when the PLC CPU detects an error, such as a watchdog timer
error, during self-diagnosis, all outputs are turned off. Also, when an error that
cannot be detected by the PLC main unit occurs in an input/output control
block, output control may be disabled. External circuits and mechanisms
should be designed to ensure safe machinery operation in such cases.
DESIGN
PRECAUTIONS
• Make sure to observe the following precautions in order to prevent any damage to
the machinery or accidents due to abnormal data written to the PLC under the
influence of noise:
1) Do not bundle the control line together with or lay it close to the main circuit or
power line. As a guideline, lay the control line at least 100mm (3.94") or more
away from the main circuit or power line. Noise may cause malfunctions.
2) Ground the shield wire or shield of a shielded cable. Do not use common
grounding with heavy electrical systems.
STARTUP AND
MAINTENANCE
PRECAUTIONS
• Do not touch any terminals or connector while the PLC's power is on.
Doing so may cause electrical shock or malfunctions.
• Before cleaning or retightening screws, externally cut off all phases of the power
supply. Failure to do so may cause malfunction or failure of the special adapter.
When the screws are tightened insufficiently, they may fall out and cause a
shortcircuit or malfunction. When tightened too much, the screws or the special
adapter may be damaged, resulting in short-circuit, or malfunction.
•
When controlling the PLC (especially when changing data, the program or
changing the operating conditions) during operation, ensure that it is safe to do so.
(Grounding resistance: 100Ω or less)
3U
D Grounding
(100Ω or less)
FX
3U
FX
3U-
ENET-ADP
2
0.5 to 1.5mm
*1
0.4 to 0.5N•m
Manufacturer Model name Model number
(AWG20 to 16)
→ FX
3U-ENET-ADP User's Manual
STARTUP AND
MAINTENANCE
PRECAUTIONS
• Do not disassemble or modify the special adapter.
Doing so may cause fire, equipment failures, or malfunctions.
• The special adapter case is made of resin. If dropped or subjected to strong
impact, the special adapter may be damaged.
• When the special adapter is installed or removed from the panel, make sure to
externally cut off all phases of the power su pply. Failure to do so may cause
malfunction or failure of the special adapter.
DISPOSAL
PRECAUTIONS
• Please contact a certified electronic waste disposal company for the
environmentally safe recycling and disposal of your device.
TRANSPORT AND
STORAGE PRECAUTIONS
• The product is a precision instrument. During transportation, avoid impacts larger
than those specified in the general specifications by using dedicated packaging
boxes and shock-absorbing palettes.
Failure to do so may cause failures in the product.
After transportation, verify operation of the product and check for damage of the
mounting part, etc.
4.1 Applicable PLC
Model name Applicability Number of connectable units
3S Series PLC
FX
3G Series PLC
FX
3GC Series PLC Ver. 2.00 or later One unit
FX
3U Series PLC
FX
3UC Series PLC
FX
The version number can be checked by reading the last three digits of device D8001 or
D8101.
*1 A connector conversion adapter is required to connect the FX
FX
*2 The FX
An expansion board is required to connect the FX3U-ENET-ADP with the FX3U/
*3
FX
*1*2
Ver. 1.00 or later One unit
*1
Ver. 2.00 or later One unit
*3
Ver. 3.10 or later One unit
*3
Ver. 3.10 or later One unit
3S/FX3G PLCs.
3S PLC is supported by FX3U-ENET-ADP Ver. 1.20 or later.
3UC-32MT-LT(-2) PLCs.
3U-ENET-ADP with
4.2 Related software
Software Model name Applicable software version
GX Works2
(SW DNC-GXW2-E)
*1 GX Works2 Ver. 1.87R or later supports the data monitoring function setting.
Parameter setting of FX
4.3 General Specifications
Items other than the following are equivalent to those of the PLC main unit.
For general specifications, refer to the User's Manual - Hardware Edition of the
connected PLC.
Item Specification
Dielectric withstand
voltage
Insulation resistance
FX
3S Series PLC Ver. 1.492N or later
3G/FX3GC Series PLC Ver. 1.87R or later
FX
3U/FX3UC Series PLC Ver. 1.73B or later
FX
3U-ENET-ADP etc. can be performed by GX Works2.
500V AC for one minute
5MΩ or higher by 500V DC
insulation resistance tester
Between all PLC
terminals and ground
terminal
*1
4.4 Power Supply Specification
Item Specification
Driving power supply
Since driving power supply (current consumption) specifications differ for other special
adapters, please take the power capacity of the main unit into consideration.
For system configuration information (calculation of the power supply capacity of the
main unit etc.), refer to the User's Manual - Hardware Edition of the connected PLC.
30mA / 5V DC
power is supplied internally from t he main unit.
5V DC
4.5 Communication Specification
Item Specification
Data transmission speed 100Mbps/10Mbps
Transmission
specifications
Communication method Full-duplex/Half-duplex
Transmission method Base band
Maximum segment length 100m (328’1’’)
4.6 Functions
Item Specification
MELSOFT connections
Communication Using MC Protocol
MELSOFT Direct Connection (Simple Connection)
Functions
Number of simultaneously
open connections allowed
Number of connectable
units to the main unit
*1 The time setting function (SNTP client) is enabled only after the trigger
condition is established.
*2 The
FX3U-ENET-ADP occupies 1 communication channel in the same way
as communication expansion boards and other communication special
adapters.
Find CPU function
Time setting function
Diagnostics function from MELSOFT
Data monitoring function
MELSOFT connection + MC protocol + Data
monitoring <= 4
*2
1 unit
*1
5. 「电器电子产品有害物质限制使用标识要求」的表示方式
Note: This symbol mark is for China only.
含有有害6物质的名称,含有量,含有部品
本产品中所含有的有害6 物质的名称,含有量,含有部品如下表
所示。
产品中有害物质的名称及含量
有害物质
部件名称
外壳 ○ ○ ○ ○ ○ ○
可编程
控制器
印刷基板 × ○ ○ ○ ○ ○
铅
(Pb)汞(Hg)镉(Cd)
六价铬
(Cr(VI))
多溴联苯
(PBB)
多溴
二苯醚
(PBDE)
本表格依据SJ/T 11364的规定编制。
○:表示该有害物质在该部件所有均质材料中的含量均在GB/T
26572规定的限量要求以下。
×: 表示该有害物质至少在该部件的某一均质材料中的含量超出 GB/T
26572规定的限量要求。
This manual confers no industrial property rights or any rights of any other kind,
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be
held responsible for any problems involving industrial property rights which may
occur as a result of using the contents noted in this manual.
Warranty
Exclusion of loss in opportunity and secondary loss from warranty liability
Regardless of the grat is warranty term, Mitsubishi shall not be liable for compensation to:
(1) Damages caused by any cause found not to be the responsibility of Mitsubishi.
(2)
Loss in opport unity, lost profits inc urred to the user by Failures of Mitsubishi products.
(3)
Special damages and secondary damages w hether foreseeable or not, compensa tion for
accidents, and compensation for damages to products other than Mitsubishi products.
(4) Replacement by the user, maintenance of on-site equipment, start-up test run
and other tasks.
For safe use
This product has been manufactured as a general-purpose part for general
industries, and has not been designed or manufactured to be incorporated in
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric
power, aerospace, medicine or passenger movement vehicles, consult with
Mitsubishi Electric.
This product has been manufactured under strict quality control. However
when installing the product where major accidents or losses could occur if the
product fails, install appropriate backup or failsafe functions in the system.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN