Mitsubishi Electric Corporation Semiconductor Group FD1500BV-90DA Datasheet

MITSUBISHI SOFT RECOVERY DIODES
FD1500BV-90DA
HIGH POWER, HIGH FREQUENCY,
PRESS PACK TYPE
FD1500BV-90DA
¡IF(AV) Average forward current ..................... 1500A
RRM
¡V ¡Q
Repetitive peak reverse voltage
RR Reverse recovery charge .................3600µC
................... 4500V
¡Press pack type
APPLICATION
Free wheel diode for GCT Thyristor
OUTLINE DRAWING Dimensions in mm
10.5 ± 1
φ3.5 ± 0.2
2.2 ± 0.2DEPTH
0.4MIN0.4MIN
26 ± 0.5
φ85 ± 0.2
φ85 ± 0.2 φ120MAX
6.35 × 10.8
TYPE NAME
12 ± 2
φ3.5 ± 0.2
2.2 ± 0.2DEPTH
High-power inverters Power supplies as high frequency rectifiers
MAXIMUM RATINGS
Parameter
VRRM VRSM VR(DC) VLTDS
Symbol Parameter UnitRatings
F(RMS)
I IF(AV) IFSM
2
I
t
di/dt Tj
Tstg
Repetitive peak reverse voltage Non-repetitive peak reverse voltage DC reverse voltage Long term DC stability voltage at 100FIT
RMS forward current Average forward current Surge forward current Current-squared, time integration Critical rate of rise of reverse recovery current Junction temperature Storage temperature Mounting force required
Weight
Conditions Applied for all conduction angles f = 60Hz, sine wave θ = 180°, T
One half cycle at 60Hz, T
I (Refer to Fig. 1 and Fig. 2)
(Recommended value 47kN) Typical 1220g
j=125°C
Voltage class
4500 4500 3600 3000
f = 65°C
3.7 × 10
–20 ~ 125 –40 ~ 150
39 ~ 55
2350 1500
30
2000
UnitSymbol
V V V V
A A
6
kA
2
A
A/µs
°C °C
kN
g
s
Feb.1999
MITSUBISHI SOFT RECOVERY DIODES
FD1500BV-90DA
HIGH POWER, HIGH FREQUENCY,
ELECTRICAL CHARACTERISTICS
Symbol Parameter Test conditions
IRRM VFM QRR Erec tb/ta
th(j-f)
R
Repetitive peak reverse current Forward voltage Reverse recovery charge Reverse recovery loss Soft recovery rate Thermal resistance
VRM = 4500V, Tj = 125°C
FM = 3400A, Tj = 125°C
I
FM = 1500A, di/dt = 1000A/µs, VR = 2250V,
I
j = 125°C
T With clamp circuit (Refer to Fig. 1 and Fig. 2) Junction to fin
Fig. 1 (Definition of reverse recovery waveform) Fig. 2 (Reverse recover y test circuit)
Min. Typ. Max.
— — — — — —
PRESS PACK TYPE
Limits
— — —
8.0 2
150
3600
0.11
3.5
— —
Unit
mA
V µC J/P
°C/W
QRR = (trr × IRM)/2
i/dt
(0~50%IFM)
trr
ta tb
IRM
d
50%IRM
90%IRM
L(load)
D
GCT
50%IFM
IFM
0
Cc
i
CD
i
Lc
CD
i
Cc
Di : FD1500BV-90DA
Rc
Cc : 6µF Rc = 2 Lc = 0.3µH
Rc
Feb.1999