[New Features]
(1) Increased range of connections to match the system configuration.
With the introduction of the 10BASE-T connection Ethernet interface module (hereinafter, Ethernet
module), the PLC and personal computer can now be connected with 10BASE5, 10BASE2, or 10BASE-T.
New product Old product
QnA
Series
A
Series
AJ71QE71N-B2 ! N/A N/A AJ71QE71 ! ! N/A
AJ71QE71N-B5T N/A ! ! AJ71QE71-B5 N/A ! N/A
A1SJ71QE71N-B2 ! N/A N/A A1SJ71QE71-B2 ! N/A N/A
A1SJ71QE71N-B5T N/A ! ! A1SJ71QE71-B5 N/A ! N/A
AJ71E71N-B2 ! N/A N/A
AJ71E71N-B5T N/A ! !
A1SJ71E71N-B2 ! N/A N/A A1SJ71E71-B2-S3 ! N/A N/A
A1SJ71E71N-B5T N/A ! ! A1SJ71E71-B5-S3 N/A ! N/A
Type
10BASE2 10BASE5 10BASE-T
(2) High-speed internal processing
With the Ethernet module's faster internal processing, the PLC responds much faster when exchanging
data with an external device.
The following table shows the minimum transmission delay time (reference value) on the PLC side when
using each communication function.
(This is based on the PLC CPU scan time of 10ms.)
Communication function Outline of communication process
Using read/write data in
the PLC CPU
Using fixed buffers
Using random access
buffers
UDP/IP communicationCommunication with binary
code dataReading of D0 to D99
TCP/IP communicationCommunication with binary
code dataCommunication of 1017 words of data
UDP/IP communicationCommunication with ASCII
code dataReading of 508 words of data
Interface (*1) Interface (*1)
*1. Indicates the communication interface for the corresponding unit. (!: Available)
Type
AJ71E71-S3 ! ! N/A
10BASE2 10BASE5 10BASE-T
QnA Series A Series
New
product
27 43 40 56
65 118 65 118
10 42 10 42
Old
product
New
product
Old
product
(Unit: ms)
2

[Function]
(1) Data communication function (TCP/IP Communication and UDP/IP Communication)
Communication Func tion Description QnA series A series
!
Using read/write data in the PLC CPU Reads/writes PLC CPU data from/to an external device.
buffers
Using random access buffers
Using data link instructions
File transfer (FTP Server Function)
Procedure exist Using fixed
No Procedure
Reads/writes any data between PLC CPU and an external device
using fixed buffer of the Ethernet modules.
Exchanges data with multiple external devic es, using the Ethernet
random access buffers. (no need to specify external device)
Reads/writes PLC CPU data of ot her stations via the Ethernet
using data link instruc tions.
Reads/writes files in the local station using the FTP server
function, from an external device.
(2) Other functions
Function Description QnA series A series
MELSECNET/10 relay communication
Router relay communication (Router
relay function)
External device existence confirmation
Paring open communic ation
Communication us i ng automatic open
UDP port
Simultaneous broadcas t
Access PLC CPU f rom GX Developer using Ethernet connecti on.
Please refer to the new module's User's Manual for the function versions and serial numbers of the products !: Applicable
(CPU module and GX Developer) related to the above functions.
Data communic at i on i s enabled over a network system where
Ethernet and MELSECNET/10 or m ul tiple Ethernet networks are
present.
Communicates data via routers and gateways. (Ethernet module
does not function as a router.)
Checks whether or not the external device operates normally after
communicati on has been established (open process i ng).
Receiving connection and transmitting connecti on are opened as a
single pair. (For fixed buffer com munication.)
Communication is enabled automaticall y af t er i n i t i al processing is
completed of local station Ethernet modul e. (Opening and closing
by a sequence program is unneces sary.)
Data is broadcasted simultaneously to all st ations on the same
Ethernet network where the Ethernet module i s located. (Using
UDP/IP)
[Performance Specifications]
Item
Transmission speed 10Mbps
Transmission m ethod Base band
Maximum node-to-node
Transmission
Specifications
Send/receive
data storage
memory
Number of occupied I/O poi nt s 32 points
5VDC current consumpt i on
12VDC external supply power capacity
(for transceiver)
*1 Between hub and node.
*2 It is necessary to use a power supply that meets the specifications of the transceiver and AUI cabl e, considering the voltage drop
(maximum 0.80V) in t he module.
distance
Maximum segment
length
Maximum number of
nodes per connection
Minimum node interval 2.5m (8.2ft.) - 0.5m (1.6ft.) 2.5m (8.2ft.) - 0.5m (1.6ft.)
Number of
simultaneously open
connections allowed
Fixed buffer
Random access buffer
AJ71QE71N-B5T
A1SJ71QE71N-B5T
10BASE5 10BASE-T 10BASE2 10BASE5 10BASE-T 10BASE2
2500m
(8203ft.)
500m
(1641ft.)
100 units/
segment
AJ71QE71N-B5T :0.48A
AJ71QE71N-B2 :0.56A
A1SJ71QE71N-B5T:0.42A
A1SJ71QE71N-B2 :0.64A
(*2) (*2)
- 925m (3035ft.)
100m
(323ft.) (*1)
Cascade
connection,
maximum 4
8 connections (Connections usable by the sequence program)
1k words × 8 1k words × 8
6k words × 1 3k words × 2
AJ71QE71N-B2
A1SJ71QE71N-B2
185m (607ft.)
30 units/ segment
Specification
(8203ft.)
(1641ft.)
100 units/
segment
AJ71E71N-B5T
A1SJ71E71N-B5T
2500m
500m
(323ft.) (*1)
connection,
maximum 4
AJ71E71N-B5T :0.48A
AJ71E71N-B2 :0.56A
A1SJ71E71N-B5T:0.42A
A1SJ71E71N-B2 :0.64A
! !
! !
! N/A
! N/A
!
!
! !
! !
!
! !
! !
AJ71E71N-B2
A1SJ71E71N-B2
- 925m (3035ft.)
100m
Cascade
185m (607ft.)
30 units/
segment
!
N/A
!
N/A
3

[External Dimensions]
The following diagram shows the AJ71QE71N-B5T and AJ71QE71N-B2. The dimensions of the
AJ71QE71N-B5T are the same as AJ71E71N-B5T. Also, the AJ71QE71N-B2 is the same as AJ71E71N-B2.
For AJ71QE71N-B5T
J71QE71N-B5T
A
RUN
BUF1
BUF2
BUF3
RDY
BUF4
BSY
SW.ERR.
BUF5
COM.ERR.
BUF6
BUF7
CPU R/W
BUF8
TEST
TEST ERR.
MODE
0:ONLINE
D
C
B
E
A
9
1:OFFLINE
8
7
2:TEST1
3
6
5
4
3:TEST2
4:TEST3
OFF ON
5:TEST4
SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW8
10BASE-T
250
(9.84)
(*1)
R1
EXT.PW
EXT.PW
(FG)
10BASE5
F
0
1
2
250
(9.84)
For AJ71QE71N-B2
55.7
(2.19)
J71QE71N-B2
A
RUN
RDY
BSY
SW.ERR.
COM.ERR.
CPU R/W
0:ONLINE
1:OFFLINE
2:TEST1
3:TEST2
4:TEST3
5:TEST4
BUF1
BUF2
BUF3
BUF4
BUF5
BUF6
BUF7
BUF8
TEST
TEST ERR.
MODE
C
8
4
OFF ON
SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW8
0
R2
(*1)
106
(4.17)
13.8
(0.54)
37.5
(1.48)
106
(4.17)
Unit: mm(inch)
The following diagram shows the A1SJ71QE71N-B5T and A1SJ71QE71N-B2. The dimensions of the
A1SJ71QE71N-B5T are the same as A1SJ71E71N-B5T. Also, the A1SJ71QE71N-B2 is the same as
A1SJ71E71N-B2.
For A1SJ71QE71N-B5T
A1SJ71QE71N-B5T
RUN
RDY
BSY
SW.ERR.
COM.ERR.
TEST
TEST ERR.
CPU R/W
MODE
0:ONLINE
1:OFFLINE
B
A
2:TEST1
9
8
3:TEST2
7
4:TEST3
5:TEST4
(*1)
10BASET
10BASE5
R2
(*1)
130
OFFON
(5.12)
R1
BUF1
BUF2
BUF3
BUF4
BUF5
BUF6
BUF7
BUF8
D
C
E
F
0
1
2
3
6
4
5
130
(5.12)
For A1SJ71QE71N-B2
56.0
(2.20)
37.5
(1.48)
1SJ71QE71N-B2
A
RUN
RDY
BSY
SW.ERR.
COM.ERR.
TEST
TEST ERR.
CPU R/W
0:ONLINE
1:OFFLINE
2:TEST1
3:TEST2
4:TEST3
5:TEST4
BUF1
BUF2
BUF3
BUF4
BUF5
BUF6
BUF7
BUF8
MODE
C
D
B
E
A
F
9
0
8
1
7
2
6
3
5
4
SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW8
OFF ON
EXT.PW
6.5
(0.26)
93.6
3.69
7.5
(0.30)
A1SJ71QE71N-B5T
34.5
1.36
6.5
(0.26)
93.6
3.69
A1SJ71QE71N-B2
34.5
1.36
Unit: mm(inch)
*1. The bending radius near the connector (reference value: R1, R2) should be four times larger or more than
the cable's external diameter when connecting the communication cable.
4

[Manual]
(1) For QnA Series Ethernet module (AJ71QE71N-B5T, AJ71QE71N-B2, A1SJ71QE71N-B5T,
A1SJ71QE71N-B2)
Manual name Manual supply status IB/SH number Model code
For QnA Ethernet Interface module User’s
Manual(Hardware)
For QnA Ethernet Interface module User’s Manual
Included with the
product
Sold separately
IB-0800182 13JT54
SH-080146 13JR33
(2) For A Series Ethernet module (AJ71E71N-B5T, AJ71E71N-B2, A1SJ71E71N-B5T, A1SJ71E71N-B2)
Manual name Manual supply status IB/SH number Model code
For A Ethernet Interface module User’s Manual(Hardware)
For A Ethernet Interface module User’s Manual
Included with the
product
Sold separately
IB-0800203 13JT70
SH-080192 13JR45
[Production discontinuation of old products]
The following old Ethernet modules will be discontinued as follows.
Product Period
QnA Series :
AJ71QE71,AJ71QE71-B5,A1SJ71QE71-B2,A1SJ71QE71-B5
A Series : AJ71E71-S3,A1SJ71E71-B2-S3,A1SJ71E71-B5-S3 Through December, 2001
Through February, 2002
5

Notes
Ethernet is a registered trademark of Xerox, Co. Ltd. of USA.
Other company names and products mentioned in this new-product release are the trademarks or registered trademarks of
their respective owners.
Country/Region Sales office Tel/Fax
U.S.A Mitsubishi Electric Automation Inc.
500 Corporate Woods Park way Vernon Hills, I L 60061
Brazil MELCO-TEC Rep. Com.e Assessori a Tecnica Ltda.
Av. Rio Branco, 123-15 ,and S/1507, Rio de Janeiro, RJ CEP 20040-005, Brazil
Germany Mitsubishi Electric Europe B. V . German Branch
Gothaer Strasse 8 D-40880 Ratingen, GE RMANY
U.K Mitsubishi Electri c Europe B.V. UK Branch
Travellers Lane, Hatfield, Hert s., AL10 8XB,UK
Italy Mitsubishi Electric Europe B.V. Itali an B ranch
Centro Dir. Colleoni, Pal. Perseo - Ingr.2
Via Paracelso 12, 20041 Agrate B., Milano, Italy
Spain Mitsubishi Elect ri c Europe B.V. Spanish B ranc h
Carretera de Rubi 76-80
08190 - Sant Cugat del Valles, B arcelona, Spain
South Africa Circuit Breaker I ndustries LTD.
Private Bag 2016, Isando 1600, Johannesburg, South Africa
Hong Kong Ryoden Automation Ltd.
10th Floor, Manulife Tower, 169 Electric Road, North Point, HongKong
China Ryoden International Shanghai Ltd.
3F Block5 Building Automation Instrum entation Plaza 103 Cao Bao Rd. Shanghai
200233 China
Taiwan Setsuyo Enterprise Co., Ltd.
6F., No.105 Wu-K ung 3rd. RD, Wu-Ku Hsiang, Tai pei Hsine, Taiwan
Korea HAN NEUNG TECHNO CO.,LTD.
1F Dong Seo Game Channel Bldg., 660-11,Deungchon-dong Kangsec-ku,
Seoul, Korea
Singapore Mitsubishi Electric Asia Pte, Ltd.
307 ALEXANDRA ROAD #05-01/02,
MITSUBISHI ELECTRIC BUI LDING SINGAPORE 159943
Thailand F. A. Tech Co.,Ltd.
898/28,29,30 S.V.CITY B UI LDI NG,OFFICE TOWER 2, FLOOR
17-18 RAMA 3 ROAD,BANGKPONGPANG,Y ANNAWA,B A NGK OK 10120
Indonesia P.T. Autoteknindo SUMBER MAKMUR
JL. MUARA KARANG SELATAN BLOK A UTARA NO.1 KAV.
NO.11 KAWASAN INDUSTRI/ PERGUDA NGA N JAKARTA - UTARA 14440
India Messung Systems Put,Ltd.
Electronic Sadan NO:111 Unit No15, M.I.D.C BHOSARI,P UNE -411026
Australia Mitsubishi Electric Australia Pty. Ltd.
348 Victoria Road, Post al B ag, No 2, Rydalmere, N.S. W 2116, Austral i a
Tel : +1-847-478-2100
Fax : +1-847-478-0328
Tel : +55-21-221-8343
Fax : +55-21-221-9388
Tel : +49-2102-486-0
Fax : +49-2102-486-717
Tel : +44-1707-276100
Fax : +44-1707-278695
Tel : +39-039-60531
Fax : +39-039-6053312
Tel : +34-935-653135
Fax : +34-935-891579
Tel : +27-11-928-2000
Fax : +27-11-392-2354
Tel : +852-2887-8870
Fax : +852-2887-7984
Tel : +86-21-6475-3228
Fax : +86-21-6484-6996
Tel : +886-2-2299-2499
Fax : +886-2-2299-2509
Tel : +82-2-3668-6567
Fax : +82-2-3664-8335
Tel : +65-473-2480
Fax : +65-476-7439
Tel : +66-2-682-6522
Fax : +66-2-682-6020
Tel : +62-21-663-0833
Fax : +62-21-663-0832
Tel : +91-20-7128927
Fax : +91-20-7128108
Tel : +61-2-9684-7777
Fax : +61-2-9684-7245
HEAD OFFICE : 1-8-12, OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212, JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI5, HIGASHI-KU, NAGOYA, JAPAN
01 (MEE)
Specifications subject to change without notic e.
Printed in Japan on recycled paper.