This manual is for the MVS 20 Vacuum Packer. The general instructions apply to the model in this category. Minipack­america LLC cannot be held responsible for any damage caused by deviating machine specifications.
This manual has been compiled with the utmost of care. Minipack-america LLC accepts no responsibility for any errors in this manual and/or the results of misinterpretation of this manual.
Minipack-america LLC is not liable for damages and/or problems that arise from using spare parts that are not supplied by Minipack-america LLC
Minipack-america LLC reserves the right to change specifications and/or spare parts without prior notification.
All rights reserved. No part of this publication may be reproduced by photocopy, printing or in any other way without prior consent from Minipack-america LLC
LIABILITY
. We exclude all liability in so far as it is not provided for by law.
1
2. Our liability shall never exceed the total amount of the order in question.
3. Barring the generally applicable legal rules of public order and good faith we are not liable to pay for any damage of
any sort whatsoever, directly or indirectly, including business losses, to movable or immovable property, or to persons, either at the opposing party as at third parties.
4. We are in any case not liable for damages arising from or cause by the use of the product supplied or by the
unsuitability of it for the goal for which the other party purchased it.
GUARANTEE
. Subject to the following limitations we give 12 months guarantee on the products supplied by us. This guarantee is
1
limited to manufacturing faults that occur and does therefore not cover breakdowns involving any parts of the supplied product that are exposed to any form of wear or usage.
2. The guarantee on parts or additions provided from third party suppliers is limited to the guarantee provided us by
the third party supplier.
3. The guarantee expires if the other party and/or third parties engaged by him use the supplied product
incompetently.
4. The guarantee also expires if the other party and/or third parties engaged by him carry out activities on i.e. make
modifications to the supplied product.
5. If we replace parts in compliance with the obligations of this guarantee then the replaced parts become our
property.
6. If the other party does not, not sufficiently, or not in a timely fashion fulfil any of the obligations arising from the
agreement reached between the parties then we are not obliged to provide this guarantee as long as the situation is occurring.
The stipulations of the guarantee and liability are part of the general terms and conditions of sale which will be sent to you if requested.
ersion 01.10 VMS 20.EN 2
V
SER MANUAL MVS 20
2
3
8
U
CONTENT USER MANUAL
NTRODUCTION / LIABILITY /
I GUARANTEE
ONTENT USER MANUAL ……….…………………………………………………………..
C
ACHINE REGISTRATIE ……….…………………………………………………………..
M
…….……………………………………………………………..
4
MPORTANT FOR INSTALLATION – READ THIS FIRST !!!! ..……………………………………………..
I
MPORTANT FOR OPERATION – READ THIS FIRST !!!! ………………………………………………
I
ARNING LABELS ……….…………………………………………………………..
W
MPORTANT MACHINE PARTS ……….…………………………………………………………..
I
TART UP AND OPERATION ……….…………………………………………………………..
S
N/OFF switch 9
ONTROL PANEL ……….…………………………………………………………..
C
ACHINE MAINTENANCE ……….…………………………………………………………..
M
O
tart the machine 9
S
tandard user operations 10
S
ontrol panel version 11
C
ontrol panel layout 11
C
ontrol panel use 12
C
eneral 14
G
mportant before and during maintenance 14
I
tandard maintenance schedule 15
S
acuum pump maintenance 15
V
eal system maintenance 18
S
ilicone holder and lid gasket maintenance 21
S
ist of maintenance parts 22
L
5
6
7
9
1
1
4
1
ECHNICAL SPECIFICATIONS ……….…………………………………………………………..
T
LECTRICAL DIAGRAMS ……….…………………………………………………………..
E
rror code 25
NEUMATIC DIAGRAMS ……….…………………………………………………………..
P
ROBLEM SOLVING ……….…………………………………………………………..
P
PECIAL APPLICATIONS ……….…………………………………………………………..
S
EMOVAL FRONT PANEL ……….…………………………………………………………..
R
E
ackaging liquid products 29
P
3
2
4
2
6
2
7
2
9
2
0
3
ersion 01.10 VMS 20.EN 3
V
SER MANUAL MVS 20
U
egister the machine using the following data. This information is necessary if the supplier or Minipack-america LLC is
R contacted concerning questions or references about the specific machine.
RIOR TO STARTING TO USE THE MACHINE,
P MACHINE REGISTRATION TO BE COMPLETED BY THE USER
DATA ON MACHINE TAG
Relevant data for answering questions can be found on the machine tag. The machine tag is located at the rear of the machine. Note down the following data:
1. MACHINE TYPE
2. MACHINE NUMBER (MACHINE NO.)
3. VOLTAGE (TENSION)
CONTROL PANEL DATA
When starting the machine two codes first appear on the display in succession before control switches to user mode. The first code indicates the software version of the control software and the second code indicates the options active. Write both codes in the space below:
4. CODE 1
5. CODE 2
ersion 01.10 VMS 20.EN 4
V
SER MANUAL MVS 20
U
IMPORTANT FOR INSTALLATION !!! READ THIS FIRST !!!
ENERAL
G
First read this manual carefully before the machine is put into operation. This manual contains relevant information
and instructions for starting up, maintenance and applications. If problems arise with the machine that could have been avoided by referring to this manual then the guarantee expires.
Minipack-america LLC wishes the customer lots of pleasure for an extended period from the purchase of the
machine. If there are any problems or questions then the customer can always approach the supplier or Minipack­america LLC.
ENVIRONMENT
The machine must be moved or transported in an upright position. The machine may NOT be tilted as this can cause
damage to the pump.
Place the machine on a flat, level floor. This is essential for problem free operation of the machine.
Enough space must be left around the machine for good ventilation. The space must be at least 5 centimetres.
The ambient temperature in which the machine is operated must be between 41 0 F and 86 0 F. When operating the
machine in other ambient temperatures the user must contact the supplier or Minipack-america LLC for advice.
NEVER place the machine directly next to a heat source or a steaming device (for example a combo-steamer,
dishwasher or stove).
POWER / EARTH
Check that the voltage stated on the machine tag is the same as the mains voltage.
Always connect the machine correctly to an earthed socket to avoid danger for fire or electrical shocks (earth
connection is green/yellow).
The power cable must always be free and nothing may be placed on it.
Replace the power cable immediately if damaged.
Always disconnect the power if there are problems with the machine or during maintenance, prior to starting work on
the machine.
If the machine is stationary for long periods then the power should always be disconnected.
ersion 01.10 VMS 20.EN 5
V
SER MANUAL MVS 20
U
VACUUM PUMP
Check before starting the machine if there is oil in the pump (see page 16). NEVER start the machine without oil in
the pump.
Use the right type of oil for the pump (see page 16).
After moving and/or transporting the machine, always first check the oil level before re-starting operation.
When starting the machine for the first time or after a lengthy idle period first run the conditioning programme before
operating the machine (see page 15).
IMPORTANT FOR OPERATION !!! READ THIS FIRST !!!
ENERAL
G
Never pack products that can be damaged during or after vacuum packaging. Live oats may never be vacuumed.
Refer to this manual if in doubt as to the operation and/or functioning of the machine. If the manual does not offer a
solution consult the supplier or Minipack-america LLC.
The guarantee and/or liability expires if damage is caused by repairs and/or changes made by you. In the case of
malfunctions contact the supplier or Minipack-america LLC.
In the case of malfunctions always stop the machine and remove the power cable from the wall socket.
GENERAL MAINTENANCE
It is essential that the machine is serviced regularly to guarantee operation and to keep the machine in optimal
condition. The maintenance schedule is clearly defined on page 15. The guarantee automatically expires due to overdue or sloppy maintenance.
Always remove the power cable from the wall socket for maintenance work, the machine must be completely
disconnected.
If there are doubts about the maintenance activities or if the machine fails to work correctly always contact the
supplier or Minipack-america LLC.
ersion 01.10 VMS 20.EN 6
V
SER MANUAL MVS 20
U
TRANSPARENT LID
Never locate the machine near a heat source. This can cause damage to the lid (cracks).
Never place hot, sharp, or heavy objects on the lid. These can cause damage to the cover (cracks) in the long run.
Always clean the cover with solvent-free cleaning agents. Solvents can damage the lid.
Check at least once a week if there are cracks in the lid. If cracks are visible in the lid then the machine must
IMMEDIATELY be turned off and not used again until the lid has been replaced. Continuing to work with a cracked lid can cause the lid to implode. All guarantees and/or liability expire in the case of accidents and/or damage caused by working with a cracked lid.
Replace the transparent cover every 4 years as a precautionary measure as a standard maintenance interval.
VACUUM PUMP
Regularly check the level and quality of the oil in the pump. If too little oil or the quality of the oil is bad (turbid),
replace or top up the oil before operating the machine (see page 16). Let the pump conditioning program run at least one full cycle before replacing the oil (see page 15).
Use the right type of oil for the pump when replacing or topping up (see page 16).
Use the conditioning program at least once a week to enhance correct and long-lasting pump operation (see page
15).
WARNING SIGNS ON THE MACHINE !!!
NLY use the prescribed power supply voltage.
O
Insert the plug firmly into the mains wall socket.
Always connect the machine to an earthed wall socket.
Always remove the plug during maintenance or when the machine is not in use for extended periods.
ersion 01.10 VMS 20.EN 7
V
SER MANUAL MVS 20
1
2 3
4 5
6
7
1
.
S
ealing bar in vacuum chamber mounted sealing supports with a click system
O
il inspection
11
O
n/Off switch and fuse holder is situated a
t
the back side of
9 10
8
12
13 14
1
U
MPORTANT MACHINE PARTS
I
. Silicone holder mounted on transparent lid
2
3. Lid gasket in lid for hermetic seal
4. Gas springs for opening lid after machine cycle
5. Vacuum / Ventilation opening
6. Control panel
7. Vacuum pressure meter
8. ON/OFF Switch
9. Oil drain plug
10. Oil fill plug
11. Oil inspection window
12. Power cable
13. Fuse holder with fuses
14. Warning stickers
Appearance of parts and machines can deviate per model from illustrations
he machine.
t
indow is situated at
w the back side of the machine.
ersion 01.10 VMS 20.EN 8
V
SER MANUAL MVS 20
U
TARTING AND OPERATING THE MACHINE
S
N/OFF SWITCH
O
The ON/OFF switch is situated at the back side of the machine and is used to turn the machine on and off before and after operation.
CAUTION – The ON/OFF switch does not completely remove all power from the machine. The power cable must be unplugged from the wall socket to remove all power from the machine. Ensure that the machine is completely without power during maintenance and repair activities is.
When the machine is turned on (with the ON/OFF switch), then the pump only runs during the vacuum cycle.
START MACHINE
When the machine is connected, then the machine can be turned on using the ON/OFF switch. When starting the machine two codes first appear in succession on the display before control switches to user mode.
The first code indicates the control software version. The second code indicates the machines active options. Note both codes on page 4 of this manual as they are important for the supplier or Minipack­america LLC when making enquiries and/or if any problems arise.
After switching to user mode the machine is ready for use. If the machine is new or has not been used for an extended period, then it is important to run the conditioning program for the pump (15 minutes) to maintain the pump. For instructions on the conditioning programme, see page 15.
After switching to the user mode the display could read [ OIL ]. This means that the operating hours counter is turned on and the set number of operating hours has elapsed. The hour counter is turned off by default but the client supplier can use it as a reminder for regular maintenance activities.
When [Oil] is displayed the machine can be still be used as usual but it is advisable to either turn off the hour counter or to reset it.
Contact the supplier or Minipack-america LLC for more information about setting or turning off the operating hours counter.