Large Capacity Vented Dryer
Angled control
T8003 / T8005
V
22 1/2"
E
23 1/2"
33 3/8" - 34 1/8"
2"
21 1/2"
3 3/4" - 4 1/2"
Location Codes
E -V-208/240 Volt, 30 Amp 5 foot molded
plug power supply connects upper right
rear (NEMA 14-30 Configuration).
Venting location may be adjusted to
lower right or left side or lower left rear
(see separate sheet).
Notes
• All installations must be done in accordance with local codes
• See "Cut-out Dimensions" sheet for undercounter or built-in space requirements
NOTE: Drawing is not to scale.
SPECIFICATION SHEETS 08262011
Page 2
Product Dimensions
Large Capacity Condeser Dryer
Angled control
T8013C
E
23 1/2"
D
22 1/2"
33 3/8" - 34 1/8"
2"
21 1/2"
CD
3 3/4" - 4 1/2"
Location Codes
E - 208/240 Volt, 30 Amp 5 foot molded
plug power supply connects upper right
rear (NEMA 14-30 Configuration).
Notes
• All installations must be done in accordance with local codes
• See "Cut-out Dimensions" sheet for undercounter or built-in space requirements
NOTE: Drawing is not to scale.
SPECIFICATION SHEETS 08262011
Page 3
Product Dimensions
Large Capacity Condenser Dryers
Flat Controls - Decor unit
T8019Ci
E
23 1/2"
D
22 1/2"
CD
1 1/2"
Location Codes
E - 208/240 Volt, 30 Amp 5 foot molded
plug power supply connects upper right
rear (NEMA 14-30 Configuration).
5 7/8"
33 3/8" - 34 1/8"
2"
3 3/4" - 4 1/2"
Notes
• All installations must be done in accordance with local codes
• See "Cut-out Dimensions" sheet for undercounter or built-in space requirements
NOTE: Drawing is not to scale.
SPECIFICATION SHEETS 08262011
Page 4
Cut-out Dimensions
Built-in Installations
Large Capacity Laundry Products
See Notes
C
24"
Water & Electrical
Connection
Location
32 3/8" - 35 1/4"
Location Codes
C - Cutout for Electric and Vent/Drain
pass-through. Adjust according to duct
or drain location.
Notes
• Needed depth will vary by model number:
T8003-T8013C: 24" minimum
T8019Ci25" minimum
• Typically requires removal of unit's lid. Out of box unit height dimension without
lid is 32 5/16" - 32 11/16".
NOTE: Drawing is not to scale.
SPECIFICATION SHEETS 08262011
Page 5
Product Dimensions
Laundry Stand
WTS410 - White Only
Notes
• For use with both large and super
capacity washers or tumble dryers.
• All installations must be done in
accordnace with local codes
22"
11"
23 3/8"
NOTE: Drawing is not to scale.
SPECIFICATION SHEETS 08262011
Page 6
Product Dimensions
Stacked Washer & Dryer
Example Combination
W3033 + T8003
E2
23 1/2"
22 1/2"
E1
V
W
D
66 3/8" - 67 1/8"
Location Codes
D -
5 foot flexible drain hose connects
upper left rear.
E1 -
120 Volt, 15 Amp 5 foot molded plug
power supply connects upper left rear
(NEMA 5-15 Configuration).
E2 -
208/240 Volt, 30 Amp 5 foot molded
plug power supply connects upper
right rear (NEMA 14-30 Configuration).
W -
5 foot separate flexible hot and cold
water intake hoses connect upper left
rear.
Notes
• All installations must be done in accordance with local codes
• See "Cut-out Dimensions" sheet for undercounter or built-in space requirements
• Remove transport struts in rear of machine before installation.
• WTV 407 Stacking kit for W3033, T8003, T8013C
• WTV 410 Stacking kit for W3039i / T8019Ci
• WTV 419 Stacking kit for W3035 / T8005
3 3/4" - 4 1/2"
2"
NOTE: Drawing is not to scale.
SPECIFICATION SHEETS 08262011
Page 7
Panel Information
Integrated Laundry
T8019Ci Decor Unit
These units come equipped with a full size white front panel. These units are also designed to either accept a thin insert or
a custom front panel supplied by the custom cabinet maker.
Sizes are as follows:
Version 1 - Thin insert
Width:23 1/4" for all machines
Thickness:up to 1/8"
Height:25" in all cases
With this version, a thin white frame will be exposed after
Miele
Decor
Laundry unit
installation
Version 2 - Custom Front Panel
Width:23 3/8" for all machines
Thickness:up to 3/4"
Height:Up to 25"
Hinge Notches
In certain installations, notches will be required to
accomodate the hinges in the front panel.
Control
Panel
3 7/8"
Miele
Decor
Laundry
C
16 3/4"
C
To center lines
With this version, the existing front panel is removed and
replaced by the new custom panel
Notch Pattern
For this installation, drill the following
pattern in the appropriate locations.
7/8"
1/4" Ø
1"
1 3/8" Ø
1"
1/4" Ø
C
Note:To insure access to customer servicable features,
a minimum 4" toe kick above finished floor (AFF)
is required.