Product Dimensions
Large Capacity Vented Dryer Angled control T8003 / T8005
V
22 1/2"
E
23 1/2"
2"
21 1/2"
3 3/4" - 4 1/2"
Location Codes
E -V-208/240 Volt, 30 Amp 5 foot molded
plug power supply connects upper right rear (NEMA 14-30 Configuration). Venting location may be adjusted to lower right or left side or lower left rear (see separate sheet).
Notes
All installations must be done in accordance with local codes
• See "Cut-out Dimensions" sheet for undercounter or built-in space requirements
NOTE: Drawing is not to scale.
SPECIFICATION SHEETS 08262011
Page 2
Product Dimensions
Large Capacity Condeser Dryer Angled control T8013C
E
23 1/2"
D
22 1/2"
2"
21 1/2"
CD
3 3/4" - 4 1/2"
Location Codes
E - 208/240 Volt, 30 Amp 5 foot molded
plug power supply connects upper right rear (NEMA 14-30 Configuration).
Notes
All installations must be done in accordance with local codes
• See "Cut-out Dimensions" sheet for undercounter or built-in space requirements
NOTE: Drawing is not to scale.
SPECIFICATION SHEETS 08262011
Page 3
Product Dimensions
Large Capacity Condenser Dryers Flat Controls - Decor unit T8019Ci
E
23 1/2"
D
22 1/2"
CD
1 1/2"
Location Codes
E - 208/240 Volt, 30 Amp 5 foot molded
plug power supply connects upper right rear (NEMA 14-30 Configuration).
5 7/8"
33 3/8" - 34 1/8"
2"
3 3/4" - 4 1/2"
Notes
All installations must be done in accordance with local codes
• See "Cut-out Dimensions" sheet for undercounter or built-in space requirements
NOTE: Drawing is not to scale.
SPECIFICATION SHEETS 08262011
Page 4
Cut-out Dimensions
Built-in Installations Large Capacity Laundry Products
See Notes
C
24"
Water & Electrical
Connection
Location
32 3/8" - 35 1/4"
Location Codes
C - Cutout for Electric and Vent/Drain
pass-through. Adjust according to duct or drain location.
Notes
• Needed depth will vary by model number: T8003-T8013C: 24" minimum T8019Ci 25" minimum
• Typically requires removal of unit's lid. Out of box unit height dimension without lid is 32 5/16" - 32 11/16".
NOTE: Drawing is not to scale.
SPECIFICATION SHEETS 08262011
Page 5
Product Dimensions
Laundry Stand WTS410 - White Only
Notes
• For use with both large and super capacity washers or tumble dryers.
• All installations must be done in accordnace with local codes
22"
11"
23 3/8"
NOTE: Drawing is not to scale.
SPECIFICATION SHEETS 08262011
Page 6
Product Dimensions
Stacked Washer & Dryer Example Combination W3033 + T8003
E2
23 1/2"
22 1/2"
E1
V
W
D
Location Codes
D -
5 foot flexible drain hose connects upper left rear.
E1 -
120 Volt, 15 Amp 5 foot molded plug power supply connects upper left rear (NEMA 5-15 Configuration).
E2 -
208/240 Volt, 30 Amp 5 foot molded plug power supply connects upper right rear (NEMA 14-30 Configuration).
W -
5 foot separate flexible hot and cold water intake hoses connect upper left rear.
Notes
All installations must be done in accordance with local codes
• See "Cut-out Dimensions" sheet for undercounter or built-in space requirements
• Remove transport struts in rear of machine before installation.
• WTV 407 Stacking kit for W3033, T8003, T8013C
• WTV 410 Stacking kit for W3039i / T8019Ci
• WTV 419 Stacking kit for W3035 / T8005
3 3/4" - 4 1/2"
2"
NOTE: Drawing is not to scale.
SPECIFICATION SHEETS 08262011
Page 7
Panel Information
Integrated Laundry T8019Ci Decor Unit
These units come equipped with a full size white front panel. These units are also designed to either accept a thin insert or a custom front panel supplied by the custom cabinet maker.
Sizes are as follows:
Version 1 - Thin insert
Width: 23 1/4" for all machines Thickness: up to 1/8" Height: 25" in all cases
With this version, a thin white frame will be exposed after
Miele
Decor
Laundry unit
installation
Version 2 - Custom Front Panel
Width: 23 3/8" for all machines Thickness: up to 3/4" Height: Up to 25"
Hinge Notches
In certain installations, notches will be required to accomodate the hinges in the front panel.
Control Panel
3 7/8"
Miele
Decor
Laundry
C
16 3/4"
C
To center lines
With this version, the existing front panel is removed and replaced by the new custom panel
Notch Pattern
For this installation, drill the following pattern in the appropriate locations.
7/8"
1/4" Ø
1"
1 3/8" Ø
1"
1/4" Ø
C
Note: To insure access to customer servicable features,
a minimum 4" toe kick above finished floor (AFF) is required.
1 1/8"
Drill all holes to a 5/8" depth
NOTE: Drawing is not to scale.
SPECIFICATION SHEETS 08262011
Page 8
Vent Locations
Vented dryers T8003, T8005
Vent Locations
Rear ViewLeft Side View
Right Side View
3 1/2" - 4 1/4"
4 3/4"
Maximum Duct Lengths
4" diameter 65 feet 4 3/16" diameter 98 feet 4 3/4" diameter 140 feet 5" diameter 196 feet
DO NOT use vinyl ducting with Miele appliances.
3 7/8" 4 3/4"
Corresponding Dryer Height with NO lid: 32 1/8" - 32 7/8"
Corresponding Dryer Height with lid: 33 3/8" - 34 1/8"
3 1/2" - 4 1/4"
Vent Duct Calculations
Type of Bend or duct Effective Radius Subtract
Flexible duct 90° 4 - 12 inches 1 3/4 feet Flexible duct 90° 12 - 20 inches 1 1/4 feet Flexible duct 45° 4 - 20 inches 1 1/4 feet Smooth duct 90° or 45° 4 - 8 inches 1 1/4 feet Elbow 90° Sharp bend 8 1/4 feet Concertina bend 8 inch 2 3/4 feet Segmented bend 8 inch 2 feet Louvered wall or window vent (#03780400) 12 1/2 feet Wall vent kit with flap (#00087184) 5 feet Window vent kit with flap (#00087185) 5 feet Exhaust connection - left 20 feet Exhaust connection - right 33 feet Flat duct (#01221330) 59 feet
3 1/2" - 4 1/4"
Page 9
Vent Locations
Stacked Washer & Dryer Example Combination
Vent Locations
Rear ViewLeft Side View Right Side View
4 3/4"
36 3/8" - 37 1/8"
3 7/8" 4 3/4"
Stacking KitStacking Kit
36 3/8" - 37 1/8"
Stacking Kit
36 3/8" - 37 1/8"
Corresponding Total Height with lid: 66 3/8" - 67 1/8"