Installationsplan / Installation plan
Installatietekening
Plan d`installation
Pianta di installazione
Plano de instalación
Plano de instalação
Σχέδιο εγκατάστασης
Asennusohje
Installasjonsplan
Installationsplan

Circled, bold-typed abbreviations:
Connection required
Abbreviations surrounded by broken circle:
Connection optional or required, depending on model
Standard voltage (delivery status) *
3 × 80 A Supply lead, wire size
* If power supply includes a stinger leg,
please call Technical Service at
USA 1-800-991-9380
CDN 1-800-643-5361
3 × 70 A Supply lead, wire size
Standard voltage (delivery status) *
3 × 63 A Supply lead, wire size
* If power supply includes a stinger leg,
please call Technical Service at
USA 1-800-991-9380
CDN 1-800-643-5361
Connection cable, min. cross-section
Input leads should not be in direct contact with any
heat source.
Input signal via potential-free (galvanically separated)
contact.
External connection thread
If necessary according to national installation
regulations, establish a potential equalization with
good pin connection.
Options/Accessories:
Machine connections:
Installationsplan PW 6321 EL
Stand: 15.04.2014 Seite 5

Max. throughput (if hot water supply is not available)
On-site connection thread
Length of connection hose (supplied)
Water requirements (average 140°F [60°C] program)
Standard connection (with hot water connection)
Additional requirements if hot water supply is not
On-site connection thread
Length of connection hose (supplied)
Water requirements (average for 140°F [60°C]
If no hot water supply, connect hose to cold water!
Main water
(Raw water)
(Optional)
On-site connection thread
Length of connection hose (supplied)
Water requirements (average for 140°F [60°C]
If no raw water supply, connect hose to cold water!
Machine drain connection (da × s × l)
On-site drain connection (di × s × l)
Vented drainage required. If ventilation is insufficient,
use with Miele kit, Mat. no. 05238090.
Drain manifolds serving several machines must be of
sufficient cross-section.
A drainage system for foam escaping from the drain
vent can be built using standard drain pipe sections.
A branch with an end cap should be provided for this
purpose.
2 × screws (Diameter × length)
2 × wall anchors (Diameter × length)
Fixing materials provided for securing to concrete
Secured dimensions (Width)
Recommended clearance to rear wall
Dynamic floor load during operation, max.
(depending on room temperature and selected
program)
1.690 W
Installation should only be carried out by authorized installers in accordance with all local and national regulations!
Observe installation instructions when installing machine! All rights reserved!
Installationsplan PW 6321 EL
Stand: 15.04.2014 Seite 5