11.11 M.-Nr. 09 284 570 / 01

Circled, bold-type abbreviations mean:
Connection required
Abbreviations surrounded by broken circle:
Connection optional or required, depending on model
Miele vapor and
foam discharge
kit
Vapor extractor in component (inner diameter)
Foam extractor supports in component (outer diameter)
Liquid condensate is drained from the vapor extractor by a
run-off system installed on-site.
Optionally, the foam can be drained into the machine
discharge through an integrated line.
Integrated foam
discharge
Machine housing lead-through (diameter)
Pressure differential, max.
Base with built-in weighing system
No external loads or weights may act on the appliance when
using the weighing system.
A temporary or static weight load on the housing can prevent
calibration of the measuring cells, with the result that faultfree functioning of the weighing system cannot be
guaranteed.
Options/Accessories:
Installationsplan / Installation plan: PW 6163 EL
Datum / Date: 16.03.2011 Seite / Page: 9

Standard voltage (as delivered) *
Connection cable (not included)
With threaded cable fitting
M 40 x 1.5
Alternative voltage
Connection cable (not included)
With threaded cable fitting
* If power supply includes a stinger leg, please contact Technical Service at
USA 1-800-991-9380
CDN 1-800-643-5361
To facilitate electrical safety checks, we recommend
connecting the appliance via a wall receptacle that can be
switched off at all poles and locked according to IEC 60309
and IEC 60947.
If the appliance is hard wired, a mains separator according
to IEC 60947 must be installed.
The wall receptacle or mains separator must be visible and
accessible after the appliance has been installed.
For added safety, we recommend installing a residual
current device in the power supply. In that case, an AC/DCsensitive residual current device is required.
If required by national regulations, a potential equalization
with good contact connection must be provided.
Max. volume flow in absence of hot and hard water supply.
Special variants, in appliances without wash agent
dispensers.
Max. volume flow in absence of hot and hard water
Threaded connector fitting at site as per DIN 44 991 (flat
sealing)
(included in delivery: 2 connector hoses + "Y" fitting)
Water requirement, standard connection with hot water
connection in 60° program ( average value)
to be provided
In absence of hot water supply, add sufficient water to
reach required connection value.
In absence of hot water supply, add sufficient water to
reach required connection value.
Special variants, in appliances without wash agent
dispensers.
Threaded connector fitting at site as per DIN 44 991 (flat
sealing)
Length of connection hose
(included in delivery: 1 connector hose)
Water requirement, standard connection with hot water
connection in 60° program ( average value)
If no hot water supply, connect the hose to the cold water
supply!
Machine connections:
Installationsplan / Installation plan: PW 6163 EL
Datum / Date: 16.03.2011 Seite / Page: 10

Threaded connector fitting at site as per DIN 44 991 (flat
sealing)
Length of connection hose
(included in delivery: 2 connector hoses + "Y" fitting)
Water requirement, standard connection with hot water
connection in 60° program ( average value)
If no hard water supply, connect the hose to the cold water
supply!
Cold water
Liquid dispensing
(Option)
Threaded connector fitting at site as per DIN 44 991 (flat
sealing)
(included in delivery: 1 connector hose)
Drainage, version
with dump valve
Drainage supports in machine (outside diameter)
On-site drain (inner diameter)
Max. transient throughput
Vented drainage required.
Drain manifolds serving several machines must be of
sufficient cross-section.
Machine side fittings for Miele vapor and foam discharge kit
.
On-site vapor and machine vent line for connection of Miele
vapor and foam discharge kit or Miele booster fan.
Externally threaded supports
If necessary, equipotential bonding with good galvanic
contact must be created
, in compliance with all applicable national
installation specifications.
Anchorage
fittings (supplied)
4 × wood screws DIN 571 (Ø × length)
4 × screw anchors (Ø × length)
Floating floor fastening material to be provided on site
.
Miele Base / Base with built-in weighing system
4 × wood screws DIN 571 (Ø × length)
4 × screw anchors (Ø × length)
Floating floor fastening material to be provided on site
.
Installationsplan / Installation plan: PW 6163 EL
Datum / Date: 16.03.2011 Seite / Page: 11

Width loading opening (clear width)
Width of wall cutout (clear width)
Height of wall cutout (clear height)
Height of wall cutout with base (clear height)
Recommended lateral interval between units
Minimum lateral separation possible
When the minimum separation is chosen this may cause
customer service additional work when performing
maintenance and repairs Complete technical installation is
then to be checked on-site and modified as necessary.
Max. floor loading in operation.
Max. drum rotation frequency
Average heat dissipation in the installation room
(depending on room temperature and selected program)
Installation should only be carried out by authorized installers and must comply with local and national building codes.
Observe installation instructions when installing this machine. Alteration rights reserved.
Installationsplan / Installation plan: PW 6163 EL
Datum / Date: 16.03.2011 Seite / Page: 12