Installationsplan / Installation plan
Installatietekening
Plan d`installation
Piano di installazione
Plano de instalación
Plano de instalação
Σχέδιο εγκατάστασης
Asennusohje
Installasjonsplan
Installationsplan
G
PT 7801 G
Materialnummer / Mat. no.: 06 738 630
Änderungsstand / Version: 00
Datum Zeichnung / Drawing date: 18.11.2005
Datum Legende / Legend date: 18.11.2005

Technical Datasheet
Tumble dryers:
Heating:
PT 7801
Gas (G)
Legend:
Circled, bold-type abbreviations:
Connection required
Abbreviations surrounded by broken circle:
Connection optional or required, depending on model
G
Optional extras:
Concrete platform
BS
Minimum height mm 50
Recommended width mm 1206
Recommended depth mm 1415
Ensure good anchorage!
Concrete plinth (to be provided on-site) optional.
Concrete platform optional (Min. quality B15)
Recommended height mm 50
Machine connections:
Electrical
connection
Fuse rating A 3 × 10
Supply lead (H 07 RN-F), min. cross-section mm² 5 × 1.5
with threaded cable connector M 25
Plug and socket connection in accordance with IEC 60309
1. Standard voltage (as supplied) V 3N AC 380-415
Frequency Hz 50 (60)
Rated load kW 1.9
recommended to facilitate electrical safety tests.
Install mains isolator according to IEC 60947 on hard-wired
connection.
Wall socket or mains isolator must be accessible after
installation.
The use of an earth leakage circuit breaker (ELCB) is strongly
recommended.
If necessary, equipotential bonding with good galvanic contact
must be provided in accordance with all appropriate national
and local regulations.
Installationsplan PT 7801 G
Stand: 18.11.2005 Seite 6

Gas connection Nominal heat load kW 36
Length of connection hose (supplied) mm 350
Connection to services Inch ½“ external thread
Natural gas
Connection thread (on site) Inch ½" internal thread
Liquid gas
or:
High-precision steel pipe according to
DIN 2391/DIN2393, to be provided on site DN 12
end without thread, min. length mm 40
Items supplied: Adapter ½“ × ⅜“ and
⅜“ × DN 12 threaded union for steel pipe.
Stopcock to be provided on site
Note installation instructions for gas-heated Miele tumble
dryers.
Local gas and plumbing regulations must be observed!
Connection pressure according to DIN EN 437
Connection pressure according to DIN EN 437
Connection thread (on site) Inch ½" internal thread
cf. Installation
Instructions
cf. Installation
Instructions
Nominal air throughput in vented mode m³/h 1080 Waste air/gas
On-site vent connection (interior diameter) mm 150
Max. temperature °C 80
As relative humidity can be as high as 100%, suitable
Type B
Note installation instructions for gas-heated Miele tumble
Local gas and plumbing regulations must be observed!
Air intake
Sufficient air intake should be available to replace displaced
=> Ducted air intake (from outside building)
Machine connection (di × s × l) [NW160] mm 161 × 4.0 × 16
On-site connection (external diameter) mm 160
Lid removal exposes live components! For safety reasons,
Machine vent connection (d
Max. pressure loss Pa 300
measures must be taken to prevent a backflow of condensate
into the machine.
gas-burning appliance
22
Waste gas pipework must be pressure-tight.
dryers.
Standard connection:
=> Air intake from installation site
Air intake grille, min. unobstructed size cm² 531
volume of air.
Alternative connection: (cf. Detail Y)
the pipe connected for central air intake should be at least
900 mm long and secured using two screws.
× s × l) [DN 150] mm 150 × 0.6 × 78
ext
Fittings (supplied)
Fixing materials for floating screed floor to be provided on site
2 × screws DIN 571 (Ø × length), provided mm 6 × 40
2 × rawl plugs (Ø × length), provided mm 10 × 50
Machine must be bolted to the floor!
Installationsplan PT 7801 G
Stand: 18.11.2005 Seite 7

Machine data Width mm 1206
Depth mm 1368
Height mm 1640
Min. access width to installation site mm 1210
Recommended rear wall gap (measured to front of machine) mm 2020
Net weight kg 300
Dynamic floor load, max. N 3414
Average heat dissipation
(dependent on ambient room temperature and programme
selected)
Acoustic power level (re1 pW) dB (A) not yet available
Sound pressure level dB (A) not yet available
(measured at a distance of 1 m from the machine and at a
height of 1.6 m)
Installation should only be carried out by authorised fitters in accordance with valid regulations!
Observe installation instructions when installing machine! All rights reserved! Measurements in mm
W not yet available
Installationsplan PT 7801 G
Stand: 18.11.2005 Seite 8